Sl No Elevation Load Grid Description Erection Wt Total load T
Load (Ton) load T
3 8.700 Within B-C , 1-2 Common discharge chute HBI Machine 10 10 3.00 13
6 12.910 Within B-C , 1-2 Two supports for HBI Machines chutes 10 10 3.00 13
7 12.910 Within 1-2, C-D Pressure releif vessel for HDI Surge bin 3 12 3.60 16
9B 18.110 Out side Axis 1, within C-D PWR 900 MM 2.5 9 2.70 12
10, 10A,10,B,10C 21.400 Within B-C , 1-2 HBI MACHINE ASSEMBLY WITH MOTOR AND GEAR BOX 560 560 168.00 728
11 21.400 Within 1-2 A-B HBI MACHINE HYD & LUB UNITS 5 5 1.50 7
11A 21.400 Within 1-2 A-B HBI MACHINE HYD & LUB UNITS 5 5 1.50 7
15A 32.060 Within C-D, 2-3 Top Gas scrubber outlet pipe 1800 4.5 17 5.10 22
15B 32.060 Within C-D, 2-3 Top Gas scrubber recycle 1000 2.5 11 3.30 14
16 32.060 Within 1-2, C-B Manit Hoist for HBI Machines 20 20 6.00 26
17 32.060 Within 1-2, C-D Hydraulic Power pack for HP & LP 20 20 6.00 26
18 32.060 Within 1'-2 , C-D Manit Hoist for HBI Machines 20 20 6.00 26
18A 32.060 Within 1-2, B-C Walkway between Feed legs for Briq screw feeder 5 5 1.50 7
19 32.060 Within 1'-2 , C-D HDRI Bubbler vent line 300mm 1 1.5 0.45 2
19A 32.060 Out side Axis 1, within C-D PWR 900 MM 2.5 10 3.00 13
20 32.060 Outside Frame Axis 2 Bustle duct Major ( 50% load considered ) 6 50 15.00 65
21 32.060 Outside Frame Axis 2 Bustle duct Minor ( 50% load considered ) 6 28 8.40 36
22A 36.650 Within 1-2, C-D TGS Over flow line 600mm 1.5 5 1.50 7
23A 36.650 Within 1-2, Outside Axis D TGS Over flow line vent 800mm 2 12 3.60 16
25A 36.650 Outside axis D within 1-2 PWS 900 mm 2.5 32 9.60 42
27 41.940 Within C-D, 1-2 TGS recirculation pump & Venturi booster pumps 5 5 1.50 7
28 41.940 Within C-D, 1-1' TGS OVER FLOW 500MM 1.5 5 1.50 7
29 41.940 Within C-B , 1-2 PDH Bubbler vent 900 2.5 3 0.90 4
31 41.940 Outside axis D within 1-2 TGS OVER FLOW VENT 800 2 7 2.10 9
34 41.940 Outside Frame Axis 2 Bustle duct Major ( 50% load considered ) 6 50 15.00 65
35 41.940 Outside Frame Axis 2 Bustle duct Minor ( 50% load considered ) 6 28 8.40 36
39 50.440 Outside Frame Axis 2 Bustle duct Major ( 50% load considered ) 6 50 15.00 65
40 50.440 Outside Frame Axis 2 Bustle duct Minor ( 50% load considered ) 6 28 8.40 36
41A 50.440 Within C-D, 2-3 Top Gas scrubber outlet pipe 1800 4.5 15 4.50 20
41B 50.440 Within C-D, 2-3 Top Gas scrubber recycle 1000 2.5 11 3.30 14
42 52.195 Outside axis 1' within C-D TGS OVER FLOW VENT 1200 3 15 4.50 20
43 52.195 Outside axis 1' within C-D PWS 900 mm 2.5 10 3.00 13
44 52.195 Outside axis D within 1-2 TGS Over flow line vent 800mm 2 7 2.10 9
45 52.195 Outside axis C within 1-2 PDH Bubbler vent 900 2.5 10 3.00 13
51 59.325 Within C-D, 2-3 grid Top Gas Scrubber Outlet pipe 2100 6 6 1.80 8
51A 59.325 Within C-D, 2-3 grid Top gas scrubber recycle 1000mm 2.5 3 0.90 4
52 59.325 Within C-B, 1-2 PDH Bubbler vent 900 2.5 3 0.90 4
53 59.915 Within 1-2, B-C SHAFT FURNACE 240 3600 1080.00 4680
54 59.915 Outside axis 1 within C-D TGS OVER FLOW 1200 3 15 4.50 20
55 59.915 Outside axis D within 1-2 TGS Over flow line vent 800mm 2 7 2.10 9
56 62.045 Outside Frame Axis 2 Bustle duct Major (100% load considered ) 6 100 30.00 130
Shaft Furnance Structure Load Details
Operating Impact
Sl No Elevation Load Grid Description Erection Wt Total load T
Load (Ton) load T
57 62.045 Outside Frame Axis 2 Bustle duct Minor (100% load considered ) 6 57 17.10 74
58 62.045 Within C-B, 1-2 PDH Bubbler vent 900 2.5 3 0.90 4
59 65.645 Within C-D,1-2 Burden feeder recirculation pump & Charge hopper flushing pump 3 3 0.90 4
61 69.645 Outside axis D within 1-2 TGS Over flow line vent 800mm 2 7 2.10 9
62 73.445 Within C-D , 1-2 TOP GAS DUCT SUPPORT 20 120 36.00 156
65 73.445 Out side Axis 2 TGS Over flow line vent 800mm 2 7 2.10 9
68 79.615 Within C-B, 1-2 PDH Bubbler vent 900 2.5 3 0.90 4
69 79.615 Out side Axis 2 TGS Over flow line vent 800mm 2 7 2.10 9
73 90.345 Out side Axis 2 TGS Over flow line vent 800mm 2 7 2.10 9
77 99.175 Out side axis 2 TGS Over flow line vent 800mm 2 7 2.10 9
79 108.645 On Axis C within 1-2 Furnace feed conveyor Gallery 150 150 45.00 195
80 108.645 Within C-B, 1-2 Furnace feed conveyor drive unit and chute 15 15 4.50 20
82 108.645 Out side axis 2 TGS Over flow line vent 800mm 2 7 2.10 9
Dead load of head end (Head frame, head pulley, drive unit, drive base frame and discharge chute) ~ 30 T
Load due to bend pulley and its supporting stool/frame ~ 5 T dead load and 15 T pull towards tail end side due to belt tension
Load details of steep angle conveyor shown in sperate drawing PEE02CASFMEXX0003 attatched
2 Please refer the floor plan drawing for details of load locations.
Shaft Furnance Structure Load Details
Operatin
NATURE OF Erection Impact Total Erection Wt Operating
Sl No Elevation Load Grid Description g Load
EQUIPMENT Wt load T load T (kg) Load (kg)
(Ton)
Outside axis B
1 8.700 QT Steam vent 700 mm PIPE/DUCT 2 2 0.60 2.60
Within 1and 2
2000 2000
Outside axis B
2 8.700 QT Steam vent 700 mm PIPE/DUCT 2 2 0.60 2.60
Within 1and 2
2000 2000
Common discharge chute HBI
3 8.700 Within B-C , 1-2 STATIC 10 10 3.00 13.00
Machine 10000 10000
4 8.700 Within B-C , 1-2 MCW Booster Pumps ( 2 Nos) ROTARY 5 5 1.50 6.50
5000 5000
10000 10000
5 12.910 Within C-D,1-2 HDRI SURGE BIN STATIC 40 160 48.00 208.00
40000 160000
9A 18.110 Within 1-2, C-D HDRI BUBBLER VENT PIPE/DUCT 1 2 0.60 2.60
1000 2000
Out side Axis 1,
9B 18.110 PWR 900 MM PIPE/DUCT 2.5 9 2.70 11.70
within C-D 2500 9000
10,
HBI MACHINE ASSEMBLY WITH
10A,10,B, 21.400 Within B-C , 1-2 ROTARY 560 560 168.00 728.00
MOTOR AND GEAR BOX 560000 560000
10C
HBI MACHINE HYD & LUB
11 21.400 Within 1-2 A-B ROTARY 5 5 1.50 6.50
UNITS 5000 5000
HBI MACHINE HYD & LUB
11A 21.400 Within 1-2 A-B ROTARY 5 5 1.50 6.50
UNITS 5000 5000
Outside axis B
14 32.060 QT Steam vent 700 mm PIPE/DUCT 2 3 0.90 3.90
Within 1and 2 2000 3000
Outside axis B
15 32.060 QT Steam vent 700 mm PIPE/DUCT 2 2 0.60 2.60
Within 1and 2
2000 2000
15A 32.060 Within C-D, 2-3 Top Gas scrubber outlet pipe 1800 PIPE/DUCT 4.5 17 5.10 22.10
4500 17000
15B 32.060 Within C-D, 2-3 Top Gas scrubber recycle 1000 PIPE/DUCT 2.5 11 3.30 14.30
2500 11000
16 32.060 Within 1-2, C-B Manit Hoist for HBI Machines ROTARY 20 20 6.00 26.00
20000 20000
17 32.060 Within 1-2, C-D Hydraulic Power pack for HP & LP ROTARY 20 20 6.00 26.00
20000 20000
18 32.060 Within 1'-2 , C-D Manit Hoist for HBI Machines ROTARY 20 20 6.00 26.00
20000 20000
Walkway between Feed legs for Briq
18A 32.060 Within 1-2, B-C STRUCTURE 5 5 1.50 6.50
screw feeder 5000 5000
19 32.060 Within 1'-2 , C-D HDRI Bubbler vent line 300mm PIPE/DUCT 1 1.5 0.45 1.95
1000 1500
Out side Axis 1,
19A 32.060 PWR 900 MM PIPE/DUCT 2.5 10 3.00 13.00
within C-D 2500 10000
Outside Frame Axis Bustle duct Major ( 50% load
20 32.060 PIPE/DUCT 6 50 15.00 65.00
2 considered ) 6000 50000
Outside Frame Axis Bustle duct Minor ( 50% load
21 32.060 PIPE/DUCT 6 28 8.40 36.40
2 considered ) 6000 28000
Outside Frame Axis
21A 32.060 Reheat line 800 mm PIPE/DUCT 2 22 6.60 28.60
2 2000 22000
22A 36.650 Within 1-2, C-D TGS Over flow line 600mm PIPE/DUCT 1.5 5 1.50 6.50
1500 5000
23 36.650 Within 1-2, C-D TGS OVER FLOW 1200 PIPE/DUCT 3 15 4.50 19.50
3000 15000
Within 1-2, Outside
23A 36.650 TGS Over flow line vent 800mm PIPE/DUCT 2 12 3.60 15.60
Axis D 2000 12000
Shaft Furnance Structure Load Details
Operatin
NATURE OF Erection Impact Total Erection Wt Operating
Sl No Elevation Load Grid Description g Load
EQUIPMENT Wt load T load T (kg) Load (kg)
(Ton)
24 36.650 Within 12, B-C PDH AND FLSG MANIFOLD STATIC 10 65 19.50 84.50
10000 65000
26 36.650 On Axis C within 1-2 HDRI BUBBLER VENT 300 PIPE/DUCT 1 2 0.60 2.60
1000 2000
Shaft Furnance Structure Load Details
Operatin
NATURE OF Erection Impact Total Erection Wt Operating
Sl No Elevation Load Grid Description g Load
EQUIPMENT Wt load T load T (kg) Load (kg)
(Ton)
28 41.940 Within C-D, 1-1' TGS OVER FLOW 500MM PIPE/DUCT 1.5 5 1.50 6.50
1500 5000
28A 41.940 Within C-D, 1-1' PWR 900 MM PIPE/DUCT 2.5 10 3.00 13.00
2500 10000
29 41.940 Within C-B , 1-2 PDH Bubbler vent 900 PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
30 41.940 Within C-D , 1-2 TGS OVER FLOW 1200 PIPE/DUCT 3 15 4.50 19.50
3000 15000
Outside axis D
31 41.940 TGS OVER FLOW VENT 800 PIPE/DUCT 2 7 2.10 9.10
within 1-2 2000 7000
Outside axis B
32 41.940 QT Steam vent 700 mm PIPE/DUCT 2 2 0.60 2.60
Within 1and 2 2000 2000
Outside axis B
33 41.940 QT Steam vent 700 mm PIPE/DUCT 2 2 0.60 2.60
Within 1and 2 2000 2000
Outside Frame Axis Bustle duct Major ( 50% load
34 41.940 PIPE/DUCT 6 50 15.00 65.00
2 considered ) 6000 50000
Outside Frame Axis Bustle duct Minor ( 50% load
35 41.940 PIPE/DUCT 6 28 8.40 36.40
2 considered ) 6000 28000
Outside Frame Axis
41.940 Reheat line 800 mm PIPE/DUCT 2 22 6.60 28.60
35A 2 2000 22000
36 44.840 Within C-B, 1-2 PDC Bubbler vent line 900 PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
Outside Frame Axis Bustle duct Major ( 50% load
39 50.440 PIPE/DUCT 6 50 15.00 65.00
2 considered ) 6000 50000
Outside Frame Axis Bustle duct Minor ( 50% load
40 50.440 PIPE/DUCT 6 28 8.40 36.40
2 considered ) 6000 28000
Outside Frame Axis
41 50.440 Reheat line 800 mm PIPE/DUCT 2 22 6.60 28.60
2 2000 22000
41A 52.195 Within C-D, 2-3 Top Gas scrubber outlet pipe 1800 PIPE/DUCT 4.5 15 4.50 19.50
4500 15000
41B 52.195 Within C-D, 2-3 Top Gas scrubber recycle 1000 PIPE/DUCT 2.5 11 3.30 14.30
2500 11000
Outside axis 1'
42 52.195 TGS OVER FLOW VENT 1200 PIPE/DUCT 3 15 4.50 19.50
within C-D 3000 15000
Outside axis 1'
43 52.195 PWS 900 mm PIPE/DUCT 2.5 10 3.00 13.00
within C-D 2500 10000
Outside axis D
44 52.195 TGS Over flow line vent 800mm PIPE/DUCT 2 7 2.10 9.10
within 1-2 2000 7000
Outside axis C within
45 52.195 PDH Bubbler vent 900 PIPE/DUCT 2.5 10 3.00 13.00
1-2 2500 10000
Outside axis B
46 52.195 QT Steam vent 700 mm PIPE/DUCT 2 2 0.60 2.60
Within 1and 2 2000 2000
Outside axis B
52.195 QT Steam vent 700 mm PIPE/DUCT 2 2 0.60 2.60
47 Within 1and 2 2000 2000
Within C-D, 1-2 Top Gas scrubber STATIC 110 600 180.00 780.00
48 52.195 110000 600000
50 55.250 Within 1-2, B-C Burden distribution cone STATIC 10 10 3.00 13.00
10000 10000
NO LOAD POINTS ON THIS
- 55.825 - - - 0
FLOOR #VALUE! 0
51 59.325 Within C-D, 2-3 grid Top Gas Scrubber Outlet pipe 2100 PIPE/DUCT 6 6 1.80 7.80
6000 6000
51A 59.325 Within C-D, 2-3 grid Top gas scrubber recycle 1000mm PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
52 59.325 Within C-B, 1-2 PDH Bubbler vent 900 PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
53 59.915 Within 1-2, B-C SHAFT FURNACE STATIC 240 3600 1080.00 4680.00
240000 3600000
Outside axis 1 within
54 59.325 TGS OVER FLOW 1200 PIPE/DUCT 3 15 4.50 19.50
C-D 3000 15000
Outside axis D
55 59.325 TGS Over flow line vent 800mm PIPE/DUCT 2 7 2.10 9.10
within 1-2 2000 7000
Shaft Furnance Structure Load Details
Operatin
NATURE OF Erection Impact Total Erection Wt Operating
Sl No Elevation Load Grid Description g Load
EQUIPMENT Wt load T load T (kg) Load (kg)
(Ton)
58 62.045 Within C-B, 1-2 PDH Bubbler vent 900 PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
3000 3000
NO LOAD POINTS ON THIS
67.645 - - 0
FLOOR #VALUE! 0
62 73.445 Within C-D , 1-2 TOP GAS DUCT SUPPORT STATIC 20 120 36.00 156.00
20000 120000
63 73.445 Within C-D , 1-2 Burden feeder tank STATIC 5 15 4.50 19.50
5000 15000
64 73.445 Within C-D , 1-2 Cold flare tank STATIC 3 3 0.90 3.90
3000 3000
65 73.445 Out side Axis 2 TGS Over flow line vent 800mm PIPE/DUCT 2 7 2.10 9.10
2000 7000
66 73.445 Within C-B, 1-2 PDH Bubbler vent PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
NO LOAD POINTS ON THIS
76.915 - - 0
FLOOR #VALUE! 0
67 79.615 On Axis C within 1-2 Top Gas Duct STATIC 7 90 27.00 117.00
7000 90000
68 79.615 Within C-B, 1-2 PDH Bubbler vent 900 PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
69 79.615 Out side Axis 2 TGS Over flow line vent 800mm PIPE/DUCT 2 7 2.10 9.10
2000 7000
70 79.615 Out side Axis C Cold flare vent PIPE/DUCT 3 3 0.90 3.90
3000 3000
72 90.345 Within C-B, 1-2 PDH Bubbler vent PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
73 90.345 Out side Axis 2 TGS Over flow line vent 800mm PIPE/DUCT 2 7 2.10 9.10
2000 7000
74 90.345 Out side Axis C Cold flare vent PIPE/DUCT 3 3 0.90 3.90
3000 3000
NO LOAD POINTS ON THIS
- 94.525 - - - 0
FLOOR #VALUE! 0
40000 470000
76 99.175 Within C-B, 1-2 PDH Bubbler vent PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
77 99.175 Out side axis 2 TGS Over flow line vent 800mm PIPE/DUCT 2 7 2.10 9.10
2000 7000
78 99.175 Out side Axis C Cold flare vent PIPE/DUCT 3 3 0.90 3.90
3000 3000
NO LOAD POINTS ON THIS
- 103.205 - - - 0
FLOOR #VALUE! 0
79 108.645 On Axis C within 1-2 Furnace feed conveyor Gallery STRUCTURE 150 150 45.00 195.00
150000 150000
Furnace feed conveyor drive unit and
80 108.645 Within C-B, 1-2 ROTARY 15 15 4.50 19.50
chute 15000 15000
81 108.645 Within C-B, 1-2 PDH Bubbler vent PIPE/DUCT 2.5 3 0.90 3.90
2500 3000
82 108.645 Out side axis 2 TGS Over flow line vent 800mm PIPE/DUCT 2 7 2.10 9.10
2000 7000
83 108.645 Out side axis C Cold flare vent PIPE/DUCT 3 3 0.90 3.90
3000 3000
**EL+8.7 **EL+8.7
**QT Steam vent 700 mm **QT Steam vent 700 mm
**No of support=4 **No of support=4
600 2600 4 5 20 6 **Empty Load=2*10/4=5kN/m 6.5 **Operating Load=2.6*10/4=6.5kN/m
**EL+8.7 **EL+8.7
**QT Steam vent 700 mm **EL+8.7
**QT Steam vent 700 mm
**No of support=4 **Common discharge chute HBI
**No of support=4
600 2600 4 5 20 6 **EL+8.7
**Empty weight=2*10/4=5kN/m 6.5 Machine
**Operating Load=2.6*10/4=6.5kN/m
**Common discharge chute HBI Machine **No of support=4
**No of support=4 **EL+8.7
**Operating
3000 13000 4 25 100 30 **EL+8.7
**Empty weight=10*10/4=25kN/m 32.5 **MCW Booster Pumps ( 2 Nos)
Load=13*10/4=32.5kN/m
**MCW Booster Pumps ( 2 Nos) **No of support=2
**No of support=2 **Operating
1500 6500 2 25 50 15 **Empty weight=5*10/2=25kN/m 32.5 Load=6.5*10/2=32.5kN/m
**EL+12.91
**EL+12.91 **By pass feeder
**By pass feeder **No of support=4
**No of support=4 **Operating
3000 13000 4 25 100 30 **Empty weight=10*10/4=25kN/m 32.5 Load=13*10/4=32.5kN/m
**EL+12.91
**EL+12.91 **HDRI SURGE BIN
**HDRI SURGE BIN **No of support=4
**No of support=4 **Operating
48000 208000 4 100 1600 480 **Empty weight=40*10/4=100kN/m 520 Load=208*10/4=520kN/m
**EL+12.91
**Two supports for HBI Machines
**EL+12.91 chutes
**Two supports for HBI Machines chutes **EL+12.91
**No of support=4
**No of support=4 **Pressure
**Operatingreleif vessel for HDI Surge
3000 13000 4 25 100 30 **EL+12.91
**Empty weight=10*10/4=25kN/m 32.5 bin
Load=13*10/4=32.5kN/m
**Pressure releif vessel for HDI Surge bin **No of support=4
**No of support=4 **EL+18.11
**Operating
3600 15600 4 7.5 120 36 **EL+18.11
**Empty weight=3*10/4=7.5kN/m 39 **PWS 900 mm
Load=15.6*10/4=39kN/m
**PWS 900 mm **No of support=4
**No of support=4 **Operating
2700 11700 4 6.25 90 27 **EL+18.11
**Empty weight=2.5*10/4=6.25kN/m 29.25 **EL+18.11
Load=11.7*10/4=29.25kN/m
**QT Steam vent 700 mm **QT Steam vent 700 mm
**No of support=4 **No of support=4
600 2600 4 5 20 6 **EL+18.11
**Empty weight=2*10/4=5kN/m 6.5 **EL+18.11
**Operating Load=2.6*10/4=6.5kN/m
**QT Steam vent 700 mm **QT Steam vent 700 mm
**No of support=4 **No of support=4
600 2600 4 5 20 6 **EL+18.11
**Empty weight=2*10/4=5kN/m 6.5 **EL+18.11
**Operating Load=2.6*10/4=6.5kN/m
**HDRI BUBBLER VENT **HDRI BUBBLER VENT
**No of support=4 **EL+18.11
**No of support=4
600 2600 4 2.5 20 6 **EL+18.11
**Empty weight=1*10/4=2.5kN/m 6.5 **PWR 900 MM
**Operating Load=2.6*10/4=6.5kN/m
**PWR 900 MM **EL+21.4
**No of support=4
**EL+21.4
**No of support=4 **HBI MACHINE ASSEMBLY WITH
**Operating
2700 11700 4 6.25 90 27 **HBI MACHINE
**Empty ASSEMBLY WITH
weight=2.5*10/4=6.25kN/m 29.25 MOTOR AND GEAR BOX
Load=11.7*10/4=29.25kN/m
MOTOR AND GEAR BOX **No of support=4
**No of support=4 **EL+21.4
**Operating
168000 728000 4 1400 5600 1680 **EL+21.4
**Empty weight=560*10/4=1400kN/m 1820 **HBI MACHINE HYD & LUB UNITS
Load=728*10/4=1820kN/m
**HBI MACHINE HYD & LUB UNITS **No of support=2
**No of support=2 **EL+21.4
**Operating
1500 6500 2 25 50 15 **EL+21.4
**Empty weight=5*10/2=25kN/m 32.5 **HBI MACHINE HYD & LUB UNITS
Load=6.5*10/2=32.5kN/m
**HBI MACHINE HYD & LUB UNITS **No of support=2
**No of support=2 **EL+32.06
**Operating
1500 6500 2 25 50 15 **EL+32.06
**Empty weight=5*10/2=25kN/m 32.5 **QT Steam vent 700 mm
Load=6.5*10/2=32.5kN/m
**QT Steam vent 700 mm **No of support=4
**No of support=4 **Operating
900 3900 4 5 30 9 **Empty weight=2*10/4=5kN/m 9.75 Load=3.9*10/4=9.75kN/m
**EL+32.06 **EL+32.06
**QT Steam vent 700 mm **QT Steam vent 700 mm
**No of support=4 **EL+32.06
**No of support=4
600 2600 4 5 20 6 **EL+32.06
**Empty weight=2*10/4=5kN/m 6.5 **Top Gas scrubber
**Operating outlet pipe 1800
Load=2.6*10/4=6.5kN/m
**Top Gas scrubber outlet pipe 1800 **No of support=4
**No of support=4 **EL+32.06
**Operating
5100 22100 4 11.25 170 51 **EL+32.06
**Empty weight=4.5*10/4=11.25kN/m 55.25 **Top Gas scrubber recycle 1000
Load=22.1*10/4=55.25kN/m
**Top Gas scrubber recycle 1000 **No of support=4
**No of support=4 **Operating
3300 14300 4 6.25 110 33 **EL+32.06
**Empty weight=2.5*10/4=6.25kN/m 35.75 **EL+32.06
Load=14.3*10/4=35.75kN/m
**EL+32.06
**Manit Hoist for HBI Machines **EL+32.06
**Manit Hoist for HBI Machines
**Hydraulic Power pack for HP & LP
**No of support=1 **Hydraulic Power pack for HP & LP
**No of support=1
6000 26000 1 200 200 60 **No of support=12
**Empty weight=20*10/1=200kN/m 260 **No of support=12
**Operating Load=26*10/1=260kN/m
**EL+32.06
**Empty **EL+32.06
**Operating
**Manit Hoist for HBI Machines
weight=20*10/12=16.6666666666667kN **Manit Hoist for HBI Machines
Load=26*10/12=21.6666666666667k
6000 26000 12 16.6666667 200 60 **No
/m of support=3 21.6666666667 **EL+32.06
**No
N/m of support=3
**EL+32.06
**Empty **Walkway
**Operatingbetween Feed legs for
**Walkway between Feed legs for Briq
weight=20*10/3=66.6666666666667kN/ Briq screw feeder
Load=26*10/3=86.6666666666667kN
6000 26000 3 66.6666667 200 screw
60 m feeder 86.6666666667 **No
/m of support=6
**No of support=6 **Operating
**Empty **EL+32.06
Load=6.5*10/6=10.8333333333333kN
1500 6500 6 8.33333333 50 15 **EL+32.06
weight=5*10/6=8.33333333333333kN/m 10.8333333333 **HDRI
/m Bubbler vent line 300mm
**HDRI Bubbler vent line 300mm **No of support=4
**No of support=4 **EL+32.06
**Operating
450 1950 4 2.5 15 4.5 **EL+32.06
**Empty weight=1*10/4=2.5kN/m 4.875 **PWR 900 MM
Load=1.95*10/4=4.875kN/m
**PWR 900 MM **EL+32.06
**No of support=4
**EL+32.06
**No of support=4 **Bustle duct Major ( 50% load
**Operating
3000 13000 4 6.25 100 30 **Bustle
**Empty duct Major ( 50% load
weight=2.5*10/4=6.25kN/m 32.5 considered )
Load=13*10/4=32.5kN/m
considered ) **EL+32.06
**No of support=4
**EL+32.06
**No of support=4 **Bustle duct Minor ( 50% load
**Operating
15000 65000 4 15 500 150 **Bustle
**Empty duct Minor ( 50% load
weight=6*10/4=15kN/m 162.5 considered )
Load=65*10/4=162.5kN/m
considered ) **No of support=4
**No of support=4 **EL+32.06
**Operating
8400 36400 4 15 280 84 **EL+32.06
**Empty weight=6*10/4=15kN/m 91 **Reheat line 800 mm
Load=36.4*10/4=91kN/m
**Reheat line 800 mm **No of support=4
**No of support=4 **EL+36.65
**Operating
6600 28600 4 5 220 66 **EL+36.65
**Empty weight=2*10/4=5kN/m 71.5 **CLASSIFIER
Load=28.6*10/4=71.5kN/m
**CLASSIFIER **No of support=2
**No of support=2 **EL+36.65
**Operating
4500 19500 2 75 150 45 **EL+36.65
**Empty weight=15*10/2=75kN/m 97.5 **TGS Over flow line 600mm
Load=19.5*10/2=97.5kN/m
**TGS Over flow line 600mm **No of support=4
**No of support=4 **EL+36.65
**Operating
1500 6500 4 3.75 50 15 **EL+36.65
**Empty weight=1.5*10/4=3.75kN/m 16.25 **TGS OVER FLOW 1200
Load=6.5*10/4=16.25kN/m
**TGS OVER FLOW 1200 **No of support=4
**No of support=4 **EL+36.65
**Operating
4500 19500 4 7.5 150 45 **EL+36.65
**Empty weight=3*10/4=7.5kN/m 48.75 **TGS Over flow line vent 800mm
Load=19.5*10/4=48.75kN/m
**TGS Over flow line vent 800mm **No of support=4
**No of support=4 **Operating
3600 15600 4 5 120 36 **Empty weight=2*10/4=5kN/m 39 Load=15.6*10/4=39kN/m
Operating Load (kN)
No of
points of
Impact Total Erection Operating Impact Operating
load Syntax Syntax
load kg load kg Wt (kN) Load (kN) load kN Total load kN **EL+36.65
applicatio **EL+36.65 **PDH AND FLSG MANIFOLD
n **PDH AND FLSG MANIFOLD **No of support=10
**No of support=10 **EL+36.65
**Operating
19500 84500 10 10 650 195 **EL+36.65
**Empty weight=10*10/10=10kN/m 84.5 **PDH BUBBLER
Load=84.5*10/10=84.5kN/m
**PDH BUBBLER **No of support=4
**No of support=4 **Operating
**EL+36.65
3600 15600 4 7.5 120 36 **EL+36.65
**Empty weight=3*10/4=7.5kN/m 39 **PWS
Load=15.6*10/4=39kN/m
900 mm
**PWS 900 mm **No of support=4
**No of support=4 **Operating
9600 41600 4 6.25 320 96 **EL+36.65
**Empty weight=2.5*10/4=6.25kN/m 104 **EL+36.65
Load=41.6*10/4=104kN/m
**HDRI BUBBLER VENT 300 **HDRI BUBBLER VENT 300
**No of support=4 **No of support=4
600 2600 4 2.5 20 6 **Empty weight=1*10/4=2.5kN/m 6.5 **Operating Load=2.6*10/4=6.5kN/m
Operating Load (kN)
No of
points of
Impact Total Erection Operating Impact Operating
load Syntax Syntax
load kg load kg Wt (kN) Load (kN) load kN Total load kN
applicatio **EL+41.94
n **EL+41.94 **TGS recirculation pump & Venturi
**TGS recirculation pump & Venturi booster pumps
booster pumps **No of support=3
**No of support=3 **Operating
**Empty **EL+41.94
Load=6.5*10/3=21.6666666666667kN
1500 6500 3 16.6666667 50 15 **EL+41.94
weight=5*10/3=16.6666666666667kN 21.6666666667 **TGS
/m OVER FLOW 500MM
**TGS OVER FLOW 500MM **No of support=4
**No of support=4 **EL+41.94
**Operating
1500 6500 4 3.75 50 15 **EL+41.94
**Empty weight=1.5*10/4=3.75kN 16.25 **PWR 900 MM
Load=6.5*10/4=16.25kN/m
**PWR 900 MM **No of support=4
**No of support=4 **EL+41.94
**Operating
3000 13000 4 6.25 100 30 **EL+41.94
**Empty weight=2.5*10/4=6.25kN 32.5 **PDH Bubbler vent 900
Load=13*10/4=32.5kN/m
**PDH Bubbler vent 900 **No of support=4
**No of support=4 **EL+41.94
**Operating
900 3900 4 6.25 30 9 **EL+41.94
**Empty weight=2.5*10/4=6.25kN 9.75 **TGS OVER FLOW 1200
Load=3.9*10/4=9.75kN/m
**TGS OVER FLOW 1200 **No of support=4
**No of support=4 **EL+41.94
**Operating
4500 19500 4 7.5 150 45 **EL+41.94
**Empty weight=3*10/4=7.5kN 48.75 **TGS OVER FLOW VENT 800
Load=19.5*10/4=48.75kN/m
**TGS OVER FLOW VENT 800 **No of support=4
**No of support=4 **Operating
2100 9100 4 5 70 21 **EL+41.94
**Empty weight=2*10/4=5kN 22.75 **EL+41.94
Load=9.1*10/4=22.75kN/m
**QT Steam vent 700 mm **QT Steam vent 700 mm
**No of support=4 **No of support=4
600 2600 4 5 20 6 **EL+41.94
**EL+41.94
**Empty weight=2*10/4=5kN 6.5 **EL+41.94
**EL+41.94
**Operating Load=2.6*10/4=6.5kN/m
**Bustle
**QT Steamductvent
Major
700( mm
50% load **Bustle
**QT Steamductvent
Major
700( mm
50% load
considered )
**No of support=4 considered )
**No of support=4
600 2600 4 5 20 **EL+41.94
6 **No of support=20.36
**Empty weight=2*10/4=5kN 6.5 **EL+41.94
**No of support=20.36
**Operating Load=2.6*10/4=6.5kN/m
**Bustle
**Empty duct Minor ( 50% load **Bustle duct Minor ( 50% load
**Operating
considered )
weight=6*10/20.36=2.94695481335953K considered )
Load=65*10/20.36=31.925343811394
15000 65000 20.36 2.94695481 500 150 **No
n/m of support=20.36 31.9253438114 **No
9kN/mof support=20.36
**EL+41.94
**Empty **EL+41.94
**Operating
**Reheat line 800 mm
weight=6*10/20.36=2.94695481335953k **Reheat line 800 mm
Load=36.4*10/20.36=17.8781925343
8400 36400 20.36 2.94695481 280 84 **No
N/m of support=20.36 17.8781925344 **No of support=20.36
811kN/m
**Empty **Operating
weight=2*10/20.36=0.982318271119843 **EL+44.84
Load=28.6*10/20.36=14.0471512770
6600 28600 20.36 0.98231827 220 66 **EL+44.84
kN/m 14.047151277 **PDC
138kN/mBubbler vent line 900
**PDC Bubbler vent line 900 **EL+50.44
**No of support=4
**EL+50.44
**No of support=4 **Bustle duct Major ( 50% load
**Operating
900 3900 4 6.25 30 9 **Bustle
**Empty duct Major ( 50% load
weight=2.5*10/4=6.25kN 9.75 considered )
Load=3.9*10/4=9.75kN/m
considered ) **EL+50.44
**No of support=4
**EL+50.44
**No of support=4 **Bustle
**Operating Minor ( 50% load
duct
15000 65000 4 15 500 150 **Bustle
**Empty duct Minor ( 50% load
weight=6*10/4=15kN 162.5 considered )
Load=65*10/4=162.5kN/m
considered ) **No of support=4
**No of support=4 **EL+50.44
**Operating
8400 36400 4 15 280 84 **EL+50.44
**Empty weight=6*10/4=15kN 91 **Reheat line 800 mm
Load=36.4*10/4=91kN/m
**Reheat line 800 mm **No of support=4
**No of support=4 **EL+52.195
**Operating
6600 28600 4 5 220 66 **EL+52.195
**Empty weight=2*10/4=5kN 71.5 **Top Gas scrubber outlet pipe 1800
Load=28.6*10/4=71.5kN/m
**Top Gas scrubber outlet pipe 1800 **No of support=4
**No of support=4 **EL+52.195
**Operating
4500 19500 4 11.25 150 45 **EL+52.195
**Empty weight=4.5*10/4=11.25kN/m 48.75 **Top Gas scrubber recycle 1000
Load=19.5*10/4=48.75kN/m
**Top Gas scrubber recycle 1000 **No of support=4
**No of support=4 **EL+52.195
**Operating
3300 14300 4 6.25 110 33 **EL+52.195
**Empty weight=2.5*10/4=6.25kN/m 35.75 **TGS OVER FLOW VENT 1200
Load=14.3*10/4=35.75kN/m
**TGS OVER FLOW VENT 1200 **No of support=4
**No of support=4 **EL+52.195
**Operating
4500 19500 4 7.5 150 45 **EL+52.195
**Empty weight=3*10/4=7.5kN 48.75 **PWS 900 mm
Load=19.5*10/4=48.75kN/m
**PWS 900 mm **No of support=4
**No of support=4 **EL+52.195
**Operating
3000 13000 4 6.25 100 30 **EL+52.195
**Empty weight=2.5*10/4=6.25kN 32.5 **TGS Over flow line vent 800mm
Load=13*10/4=32.5kN/m
**TGS Over flow line vent 800mm **No of support=4
**No of support=4 **EL+52.195
**Operating
2100 9100 4 5 70 21 **EL+52.195
**Empty weight=2*10/4=5kN 22.75 **PDH Bubbler vent 900
Load=9.1*10/4=22.75kN/m
**PDH Bubbler vent 900 **No of support=4
**No of support=4 **Operating
3000 13000 4 6.25 100 30 **EL+52.195
**Empty weight=2.5*10/4=6.25kN 32.5 **EL+52.195
Load=13*10/4=32.5kN/m
**QT Steam vent 700 mm **QT Steam vent 700 mm
**No of support=4 **No of support=4
600 2600 4 5 20 6 **EL+52.195
**Empty weight=2*10/4=5kN 6.5 **EL+52.195
**Operating Load=2.6*10/4=6.5kN/m
**QT Steam vent 700 mm **QT Steam vent 700 mm
**No of support=4 **EL+52.195
**No of support=4
600 2600 4 5 20 6 **EL+52.195
**Empty weight=2*10/4=5kN 6.5 **Top Gas scrubber
**Operating Load=2.6*10/4=6.5kN/m
**Top Gas scrubber **No of support=8
**No of support=8 **EL+55.25
**Operating
180000 780000 8 137.5 6000 1800 **EL+55.25
**Empty weight=110*10/8=137.5kN/m 975 **Reheat HEADERS 800 mm
Load=780*10/8=975kN/m
**Reheat HEADERS 800 mm **No of support=1
**No of support=1 **EL+55.25
**Operating
11400 49400 1 50 380 114 **EL+55.25
**Empty weight=5*10/1=50kN 494 **Burden distribution cone
Load=49.4*10/1=494kN/m
**Burden distribution cone **No of support=4
**No of support=4 **Operating
3000 13000 4 25 100 30 **Empty weight=10*10/4=25kN 32.5 Load=13*10/4=32.5kN/m
**EL+59.325
0 0 **EL+59.325 0 **Top Gas Scrubber Outlet pipe 2100
**Top Gas Scrubber Outlet pipe 2100 **No of support=4
**No of support=4 **EL+59.325
**Operating
1800 7800 4 15 60 18 **EL+59.325
**Empty weight=6*10/4=15kN 19.5 **Top gas scrubber recycle 1000mm
Load=7.8*10/4=19.5kN/m
**Top gas scrubber recycle 1000mm **No of support=4
**No of support=4 **EL+59.325
**Operating
900 3900 4 6.25 30 9 **EL+59.325
**Empty weight=2.5*10/4=6.25kN 9.75 **PDH Bubbler vent 900
Load=3.9*10/4=9.75kN/m
**PDH Bubbler vent 900 **No of support=4
**No of support=4 **EL+59.915
**Operating
900 3900 4 6.25 30 9 **EL+59.915
**Empty weight=2.5*10/4=6.25kN 9.75 **SHAFT FURNACE
Load=3.9*10/4=9.75kN/m
**SHAFT FURNACE **No of support=8
**No of support=8 **EL+59.325
**Operating
1080000 4680000 8 300 36000 10800 **EL+59.325
**Empty weight=240*10/8=300kN 5850 **TGS OVER FLOW 1200
Load=4680*10/8=5850kN/m
**TGS OVER FLOW 1200 **No of support=4
**No of support=4 **EL+59.325
**Operating
4500 19500 4 7.5 150 45 **EL+59.325
**Empty weight=3*10/4=7.5kN 48.75 **TGS Over flow line vent 800mm
Load=19.5*10/4=48.75kN/m
**TGS Over flow line vent 800mm **No of support=4
**No of support=4 **Operating
2100 9100 4 5 70 21 **Empty weight=2*10/4=5kN 22.75 Load=9.1*10/4=22.75kN/m
Operating Load (kN)
No of
points of
Impact Total Erection Operating Impact Operating
load Syntax Syntax
load kg load kg Wt (kN) Load (kN) load kN **EL+62.045 Total load kN **EL+62.045
applicatio **Bustle duct Major (100% load **Bustle duct Major (100% load
n considered ) **EL+62.045
considered )
**EL+62.045
**No of support=4 **Bustle duct Minor (100% load
**No of support=4
30000 130000 4 15 1000 300 **Bustle
**Empty duct Minor (100% load
weight=6*10/4=15kN 325 considered
**Operating) Load=130*10/4=325kN
considered ) **No of support=4
**No of support=4 **Operating
17100 74100 4 15 570 171 **EL+62.045
**Empty weight=6*10/4=15kN 185.25 **EL+62.045
Load=74.1*10/4=185.25kN
**PDH Bubbler vent 900 **PDH Bubbler vent 900
**No of support=4 **No of support=4
900 3900 4 6.25 30 9 **Empty weight=2.5*10/4=6.25kN 9.75 **Operating Load=3.9*10/4=9.75kN
**EL+65.645 **EL+65.645
**Burden feeder recirculation pump & **Burden feeder recirculation pump
Charge hopper flushing pump & Charge hopper flushing pump
**No of support=3 **No of support=3
900 3900 3 10 30 9 **Empty weight=3*10/3=10kN/m 13 **Operating Load=3.9*10/3=13kN/m
0 0 **EL+69.645 **EL+69.645
**MAINT HOIST **MAINT HOIST
**No of support=3 **No of support=3
**Empty **EL+69.645
**Operating
2400 10400 3 26.6666667 80 24 **EL+69.645
weight=8*10/3=26.6666666666667kN/m 312 **TGS Over flow line vent 800mm
Load=10.4*10/3=312kN/m
**TGS Over flow line vent 800mm **No of support=4
**No of support=4 **EL+73.445
**Operating
2100 9100 4 5 70 21 **EL+73.445
**Empty weight=2*10/4=5kN/m 364 **TOP GAS DUCT SUPPORT
Load=9.1*10/4=364kN/m
**TOP GAS DUCT SUPPORT **No of support=4
**No of support=4 **EL+73.445
**Operating
36000 156000 4 50 1200 360 **EL+73.445
**Empty weight=20*10/4=50kN/m 390 **Burden feeder tank
Load=156*10/4=390kN/m
**Burden feeder tank **No of support=2
**No of support=2 **EL+73.445
**Operating
4500 19500 2 25 150 45 **EL+73.445
**Empty weight=5*10/2=25kN/m 97.5 **Cold flare tank
Load=19.5*10/2=97.5kN/m
**Cold flare tank **No of support=2
**No of support=2 **EL+73.445
**Operating
900 3900 2 15 30 9 **EL+73.445
**Empty weight=3*10/2=15kN/m 19.5 **TGS Over flow line vent 800mm
Load=3.9*10/2=19.5kN/m
**TGS Over flow line vent 800mm **No of support=4
**No of support=4 **EL+73.445
**Operating
2100 9100 4 5 70 21 **EL+73.445
**Empty weight=2*10/4=5kN/m 22.75 **PDH Bubbler vent
Load=9.1*10/4=22.75kN/m
**PDH Bubbler vent **No of support=4
**No of support=4 **Operating
900 3900 4 6.25 30 9 **Empty weight=2.5*10/4=6.25kN/m 9.75 Load=3.9*10/4=9.75kN/m
**EL+79.615
0 0 **EL+79.615 **Top Gas Duct
**Top Gas Duct **No of support=1
**No of support=1 **Operating
27000 117000 1 70 900 270 **EL+79.615
**Empty weight=7*10/1=70kN/m 1170 **EL+79.615
Load=117*10/1=1170kN/m
**PDH Bubbler vent 900 **PDH Bubbler vent 900
**No of support=1 **No of support=1
900 3900 1 25 30 9 **EL+79.615
**Empty weight=2.5*10/1=25kN/m 39 **EL+79.615
**Operating Load=3.9*10/1=39kN/m
**TGS Over flow line vent 800mm **TGS Over flow line vent 800mm
**No of support=1 **No of support=1
2100 9100 1 20 70 21 **EL+79.615
**Empty weight=2*10/1=20kN/m 91 **EL+79.615
**Operating Load=9.1*10/1=91kN/m
**Cold flare vent **Cold flare vent
**No of support=1 **No of support=1
900 3900 1 30 30 9 **EL+83.715
**Empty weight=3*10/1=30kN/m 39 **EL+83.715
**Operating Load=3.9*10/1=39kN/m
**Hydraulic Accumulator **Hydraulic Accumulator
**No of support=1 **No of support=1
600 2600 1 20 20 6 **EL+90.345
**Empty weight=2*10/1=20kN/m 26 **EL+90.345
**Operating Load=2.6*10/1=26kN/m
**PDH Bubbler vent **PDH Bubbler vent
**No of support=1 **No of support=1
900 3900 1 25 30 9 **EL+90.345
**Empty weight=2.5*10/1=25kN/m 39 **EL+90.345
**Operating Load=3.9*10/1=39kN/m
**TGS Over flow line vent 800mm **TGS Over flow line vent 800mm
**No of support=1 **No of support=1
2100 9100 1 20 70 21 **EL+90.345
**Empty weight=2*10/1=20kN/m 91 **EL+90.345
**Operating Load=9.1*10/1=91kN/m
**Cold flare vent **Cold flare vent
**No of support=1 **No of support=1
900 3900 1 30 30 9 **Empty weight=3*10/1=30kN/m 39 **Operating Load=3.9*10/1=39kN/m
0 0
**EL+99.175 **EL+99.175
**Charge Hopper **Charge Hopper
**No of support=3 **No of support=3
**Empty **Operating
weight=40*10/3=133.333333333333kN/ **EL+99.175
Load=611*10/3=2036.66666666667k
141000 611000 3 133.333333 4700 1410 **EL+99.175
m 2036.67 **PDH
N/m Bubbler vent
**PDH Bubbler vent **No of support=4
**No of support=4 **EL+99.175
**Operating
900 3900 4 6.25 30 9 **EL+99.175
**Empty weight=2.5*10/4=6.25kN/m 9.75 **TGS Over flow line vent 800mm
Load=3.9*10/4=9.75kN/m
**TGS Over flow line vent 800mm **No of support=4
**No of support=4 **EL+99.175
**Operating
2100 9100 4 5 70 21 **EL+99.175
**Empty weight=2*10/4=5kN/m 22.75 **Cold flare vent
Load=9.1*10/4=22.75kN/m
**Cold flare vent **No of support=4
**No of support=4 **Operating
900 3900 4 7.5 30 9 **Empty weight=3*10/4=7.5kN/m 9.75 Load=3.9*10/4=9.75kN/m
0 0
**EL+108.645
**EL+108.645 **Furnace feed conveyor Gallery
**Furnace feed conveyor Gallery **EL+108.645
**No of support=4
**EL+108.645
**No of support=4 **Furnace
**Operatingfeed conveyor drive unit
45000 195000 4 375 1500 450 **Furnace feed conveyor drive unit and
**Empty weight=150*10/4=375kN/m 487.5 and chute
Load=195*10/4=487.5kN/m
chute **No of support=3
**No of support=3 **EL+108.645
**Operating
4500 19500 3 50 150 45 **EL+108.645
**Empty weight=15*10/3=50kN/m 65 **PDH Bubbler vent
Load=19.5*10/3=65kN/m
**PDH Bubbler vent **No of support=4
**No of support=4 **EL+108.645
**Operating
900 3900 4 6.25 30 9 **EL+108.645
**Empty weight=2.5*10/4=6.25kN/m 9.75 **TGS Over flow line vent 800mm
Load=3.9*10/4=9.75kN/m
**TGS Over flow line vent 800mm **No of support=4
**No of support=4 **EL+108.645
**Operating
2100 9100 4 5 70 21 **EL+108.645
**Empty weight=2*10/4=5kN/m 22.75 **Cold flare vent
Load=9.1*10/4=22.75kN/m
**Cold flare vent **EL+114.52
**No of support=4
**EL+114.52
**No of support=4 **Maint Hoist
**Operating
900 3900 4 7.5 30 9 **Maint
**Empty Hoist
weight=3*10/4=7.5kN/m 9.75 **No of support=6
Load=3.9*10/4=9.75kN/m
**No of support=6 **Operating
**Empty Load=6.5*10/6=10.8333333333333kN
1500 6500 6 8.33333333 50 15 weight=5*10/6=8.33333333333333kN/m 10.8333333333 /m
2066550 8955050
0 0
4 nodes
4 nodes
4 nodes
4 nodes
monorail,hold
beam 12 nodes
kn/m,applied, doubt
6nodes
beam
bracing 4
4 nodes
4 nodes
nodal
nodal
nodal
nodal
nodal
nodal
nodal
.37m(point load)
nodal
nodal
nodal
nodal
nodal
nodal
nodal
running length=10.18m
running length=10.18m
running length=10.18m
node
node
node
node
node
node
node
node
node
node
node
member load
node
node,59.325
node,59.325
node,59.325
node,59.325
node,59.325
apply load with 4 nodes,confirmed with priyanka(final will be done by her)
POINT LOAD(BEAM)
NODE
NODE
NODE
NODE
Done by sathya
Done by sathya
Done by sathya
Done by sathya
Done by sathya
Done by sathya
Done by sathya
Done by sathya
Done by sathya
node
node
node
beam node