Contents
1. INTRODUCTION ............................................................................................. 4
2. REFERENCE................................................................................................... 4
3. DEFINITION .................................................................................................... 4
4. MATERIALS SPECIFICATION ........................................................................ 4
5. ATTACHMENT ................................................................................................ 7
Date : Oct 18, 2023 MATERIAL APPROVAL FOR ROOFING, SIDING, MS-DD-AKPQ4-ENG-SPE-0004
AND GUTTER MATERIAL FOR STEEL Page 3 of 7
Rev. : 5 STRUCTURE WORK
1. INTRODUCTION
This document defines the material approval for roofing, siding, Downspout and gutter
only for those using zincalume material with all requirements needed to achieve the site
work in a safe and appropriate manner. (Stainless Steel material that will be used only for
the roof of FCF/FSF/Anode Shelter will be submitted at different document)
2. REFERENCE
The following documents are references used during development of procedure:
• MS-DD-3000-STR-SPE-0001 – Construction Specification for Fabrication and Erection
of Steel Structure
• MS-DD-3000-ACT-SPE-0002 – Construction Specification for Architecture Material
3. DEFINITION
4. MATERIALS SPECIFICATION
Refer to the Main Contractor document specification no. MS-DD-3000-ACT-SPE-0002 –
Construction Specification for Architecture Material, requirement specification material
for roofing, siding, and gutter shall be Lysaght BlueScope material. as follows:
- Pre-painted Formed from 0.6 mm thick zinc Colorbond XRW steel sheet
finish and aluminum, Painting coating formed 0.6 mm thick with AZ 150
shall be satisfied requirement of substrate and Custom formulated
AS 2728 TYPE 4. (MS-DD-3000- super polyester paint system with
ACT-SPE-0002 pg. 25) high performance pigments Finish
Coating. Nominal thickness 25
micron on the top or weather side
and 10 micron on the back side,
coating class comply the AS 2728 :
1997 Type 4
- Fluoride Formed from 0.6 mm thick zinc Colorbond XPD steel sheet formed
Coat and aluminum, Coating shall be 0.6 mm BMT thick with AZ 150
satisfied requirement of AS 2728 substrate and custom formulated
TYPE 3. (MS-DD-3000-ACT-SPE- system – PVDF (Polyvinylidene
0002 pg 25) Fluoride) both sides finish coating.
Nominal thickness 25 micron on
the top or weather side and back
side, coating class comply the AS
2728 : 1997 Type 3 standard (Doc
Page 11 & 14)
- Translucent Translucent sheeting shall be V-SKY Fibre Reinforced Plastic
Finish 1.5mm thick Fiber Reinforced (FRP) formed 1.5 mm with a
Plastic to the same profile as the diffused light transmission as
adjacent metal sheeting material color requirement Clear = 70%
and comply with ASTM D3841 (Doc Page 26)
with a diffused light transmission
of 70%.
3 Flashing
- Roof Roof Connector, Eaves Frame, Colorbond XPD steel sheet formed
Flashing Eaves Closer, Eaves Flashing, 0.6 mm BMT thick with AZ 150
Gable Flashing, End Closer, substrate and custom formulated
Siding Closer, Junction Flashing, system – PVDF (Polyvinylidene
Apron, Ridge Covering, Under Fluoride) both sides finish coating.
Gable Flashing, and other Nominal thickness 25 micron on
Standard Roof Special Shapes. the top or weather side and back
Formed from the same material side, coating class comply the AS
as roof sheet. 2728 : 1997 Type 3 standard (Doc
Page 34)
- Siding Corner Covering, End Wall - Colorbond XRW steel sheet
Flashing Flashing, and other Standard formed 0.6 mm thick with AZ
Siding Special Shapes Formed 150 substrate and Custom
from the same material as siding formulated super polyester
sheet. paint system with high
Date : Oct 18, 2023 MATERIAL APPROVAL FOR ROOFING, SIDING, MS-DD-AKPQ4-ENG-SPE-0004
AND GUTTER MATERIAL FOR STEEL Page 6 of 7
Rev. : 5 STRUCTURE WORK
5. ATTACHMENT
Attachment – 1 : Technical Datasheet Lysaght BlueScope
ATTACHMENT -1
LYSAGHT BLUESCOPE
01. ROOFING AND SIDING
PROPERTIES SPESIFICATION
RAL
7047
25 mm
Typical Properties
Substrate : Zincalume® XRW Steel
Coating Class : AZ 150
Nominal Coating Mass : 200 gr/sqm both surface
Primer Coat : Universal Corrosion inhibitive primer
Finish Coat : Custom formulated super polyester paint system with high
performance pigments finish system
Coating Thickness : 35 micron (Weather side + backside)
Surface Condition : Painted
Standard
Paint Coating : AS/NZS 2728:2013 Type 4
Substrate : AS 1397:2011 ; SNI 4096:2007
Mechanical Properties
GUARANTEED
Parameter
G550’ G300’
Yield Strength (Mpa) 550 300
Tensile Strength (Mpa) 550 340
Elongation in 50 mm (% EL) 2 20
Typical Properties
Substrate : Zincalume® XPD Steel G550
Zincalume® XPD Steel G300
Coating Class : AZ 150
Primer Coat : Corrosion inhibitive primer
Finish Coat : Custom formulated system – PVDF (Polyvinylidene Fluoride)
coating system
Coating Thickness : 50 micron (Top coated both sides) for Roofing
35 micron (weather side and back side) for Cladding
Surface Condition : Painted
Gloss : Nominal 25% (600)
Standard
Paint Coating : AS/NZS 2728:2013 Type 3
Substrate : AS 1397:2011, SNI 4096:2007
Mechanical Properties
GUARANTEED
Parameter
G550’ G300’ 340”
Yield Strength (Mpa) 550 300 340
Tensile Strength (Mpa) 550 340 -
Elongation in 50 mm (% EL) 2 20 12
1800 transverse bend (L axis) - 2t -
Prepainted - PP
INDONESIA STANDARD
SNI 4096:2007 Baja lembaran dan gulungan lapis paduan
Aluminium – seng (Bj.L AS)
PRODUCT INFORMATION
ZINCALUME® G550 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
SUBSTRATE
ZINCALUME® G300 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
PRETREATMENT Corrosion resistant proprietary conversion coating
PRIMER COAT Universal corrosion inhibitive primer. Nominal dry film thickness 5µm each side
FINISH COAT Custom formulated PVDF paint system with high performance pigments. Nominal dry film thickness 20µm on
the top or weather side.
BACKING COAT Custom formulated Shadow Grey. Nominal dry film thickness 5µm
COLOUR A range of colours is available. Other specifically required colours may be available on request.
Zincalume® AZ150
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
Guaranteed Minimum
Mechanical Properties
G300 G550
Yield Strength (MPa) 300 550
Tensile Strength (MPa) 340 550
Elongation (% - on 50mm) 20 2
Chemical Properties of Steel Based
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PRODUCT ATTRIBUTES
PROPERTY TEST & EVALUATION METHOD (S) RESULTS
Resistance to Abrasion
Scratch AS2331.4.7 Typically 2000g
Flexibility
T-bend ASTM D4145 Maximum 10T (no cracking). Refer Note 7
Adhesion
Natural well washed exposure (15 years) AS/NZS 1580.457.1 No flaking or peeling. Refer Notes 9 & 10
Resistance to Humidity
Cleveland (500 hours) ASTM D4585; AS/NZS 1580.481.1.9 (Blisters); Blister density: ≤3. Blister size: ≤S2. No loss of
AS 1580.408.4 (Adhesion) adhesion or corrosion
Resistance to Corrosion
Salt spray (1000 hours) AS/NZS2728 (Appendix I), ASTM B117, Blister density: ≤2. Blister size: ≤S3. Undercut
AS2331.3.1, AS/NZS 1580.481.1.9 (Blisters), from score: ≤2mm. No loss of adhesion or
AS1580.408.4 (Adhesion) corrosion. Refer Note 2
Resistance to Colour Change
QUV (2000 hours) ASTM G154 & ASTM D2244 (Colour) ΔE CIELAB 2000: Intermediate colour: ≤ 5 units
Resistance to Chalking
Natural well washed exposure (10 years) AS/NZS 1580.457.1 & AS/NZS 1580.481.1.11 Chalk Rating: ≤4. Refer Notes 9 & 10
(Chalk Method B)
QUV (2000 hours) ASTM G154 & AS/NZS 1580.481.1.11 (Chalk Chalk Rating: ≤4
Method B)
Resistance to Solvents
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Acids
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Alkalis
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Fire
Exposure AS/NZS 1530.3 Ignibility Index: 0 rating in scale of 0-20;
Spread of Flame Index: 0 rating in scale of 0-10;
Heat Evolved Index: 0 rating in scale of 0-10;
Smoke Evolved Index: 0-1 rating in scale of 0-10
Resistance to Heat
Exposure 100°C continuous (500 hours) ASTM D2244 (Colour) Colour change ΔE CIELAB 2000: ≤3 units
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
IMPORTANT NOTES
1. All warranties for a product, if any, are subject to eligibility. Terms and conditions apply. Nothing in this document is intended by
BlueScope to extend, modify or otherwise affect any stated product warranty. To find out more, please contact your nearest
BlueScope sales office.
2. If it is intended to use Clean COLORBOND® XPD steel in an exterior application within 1km of salt marine locations, severe industrial
or abnormally corrosive environments; in areas not washed by rain, or in applications where it will be wholly or partly buried in the
ground, please contact your nearest BlueScope sales office for specialized advice. For selection of the most appropriate Clean
COLORBOND® XPD product, please refer to Technical Bulletins TB1a, TB1b, CTB16, CTB21, CTB22.
3. Customers should use product promptly (within 6 months) to avoid the possibility of storage related corrosion.
4. Finish Coat – the coating applied to the exposed surface of the prepainted coil which is expected to meet the Performance
Requirements.
5. The product is supplied with a nominal 25 unit (60°) gloss Finish Coat.
6. Backing Coat – a thin coating applied to the reverse surface of the prepainted coil. It also gives additional durability to the reverse
surface during the service life of the product, but for aesthetic reasons is not recommended for exposure to sunlight. Performance
Requirements are generally not applicable to backing coats. Where specific Performance Requirements are deemed necessary for
the reverse surface coating, a “double sided” product should be specified, in which case a topcoat of full nominal thickness will be
applied.
7. The minimum internal bend diameters for forming processes to achieve no paint cracking (visible using x 10 magnification) and to
avoid paint adhesion issues are specified by the T-bend flexibility and T-bend adhesion results respectively – where 1T equals the
Total Coated Thickness (TCT) in mm of the material. These results are based on testing at 20-25°C.
8. For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss of ductility
compared with unpainted product. However, minimum strength levels designated by relevant standards will still be applicable.
9. Improper storage or use of non-approved roll-forming lubricants may cause brand transfer and paint blushing, and may adversely
affect colour and long term durability. Product in coil or sheet pack form must be kept dry. If the coil or sheet pack becomes wet, it
must be separated and dried (refer AS/NZS2728 Appendix L, and also Technical Bulletin TB7). Contact nearest BlueScope sales
office on appropriate rollforming lubricants.
10. Values quoted are for panels exposed in accordance with AS/NZS2728. Variations for in-situ performance may occur due complexity
of building design and location.
11. Clean COLORBOND® XPD has good resistance to accidental spillage of solvents such as methylated spirits, white sprit, mineral
turpentine, toluene, and trichloroethylene and dilute mineral acids and alkalis. However, all spillages should be immediately removed
by water washing and drying.
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
INDONESIA STANDARD
SNI 4096:2007 Baja lembaran dan gulungan lapis paduan
Aluminium – seng (Bj.L AS)
PRODUCT INFORMATION
ZINCALUME® G550 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
SUBSTRATE
ZINCALUME® G300 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
PRETREATMENT Corrosion resistant proprietary conversion coating
PRIMER COAT Universal corrosion inhibitive primer. Nominal dry film thickness 5µm each side
FINISH COAT Custom formulated super polyester paint system with high performance pigments. Nominal dry film thickness
20µm on the top or weather side.
BACKING COAT Custom formulated Shadow Grey. Nominal dry film thickness 5µm
COLOUR A range of standard colours is available. Other specifically required colours may be available on request.
Zincalume® AZ150
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
Guaranteed Minimum
Mechanical Properties
G300 G550
Yield Strength (MPa) 300 550
Tensile Strength (MPa) 340 550
Elongation (% - on 50mm) 20 2
Chemical Properties of Steel Based
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PRODUCT ATTRIBUTES
PROPERTY TEST & EVALUATION METHOD (S) RESULTS
Resistance to Abrasion
Scratch AS2331.4.7 Typically 2000g
Flexibility
T-bend ASTM D4145 Maximum 10T (no cracking). Refer Note 7
Adhesion
Natural well washed exposure (15 years) AS/NZS 1580.457.1 No flaking or peeling. Refer Notes 9 & 10
Resistance to Humidity
Cleveland (500 hours) ASTM D4545; AS/NZS 1580.481.1.9 (Blisters); Blister density: ≤3. Blister size: ≤S2. No loss of
AS 1580.408.4 (Adhesion) adhesion or corrosion
Resistance to Corrosion
Salt spray (1000 hours) AS/NZS2728 (Appendix I), ASTM B117, Blister density: ≤2. Blister size: ≤S3. Undercut
AS2331.3.1, AS/NZS 1580.481.1.9 (Blisters), from score: ≤2mm. No loss of adhesion or
AS1580.408.4 (Adhesion) corrosion. Refer Note 2
Resistance to Colour Change
QUV (2000 hours) ASTM G154 & ASTM D2244 (Colour) ΔE CIELAB 2000: Intermediate colour: ≤ 5 units
Resistance to Chalking
Natural well washed exposure (10 years) AS/NZS 1580.457.1 & AS/NZS 1580.481.1.11 Chalk Rating: ≤4. Refer Notes 9 & 10
(Chalk Method B)
QUV (2000 hours) ASTM G154 & AS/NZS 1580.481.1.11 (Chalk Chalk Rating: ≤4
Method B)
Resistance to Solvents
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Acids
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Alkalis
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Fire
Exposure AS/NZS 1530.3 Ignibility Index: 0 rating in scale of 0-20;
Spread of Flame Index: 0 rating in scale of 0-10;
Heat Evolved Index: 0 rating in scale of 0-10;
Smoke Evolved Index: 0-1 rating in scale of 0-10
Resistance to Heat
Exposure 100°C continuous (500 hours) ASTM D2244 (Colour) Colour change ΔE CIELAB 2000: ≤3 units
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
IMPORTANT NOTES
1. All warranties for a product, if any, are subject to eligibility. Terms and conditions apply. Nothing in this document is intended by
BlueScope to extend, modify or otherwise affect any stated product warranty. To find out more, please contact your nearest
BlueScope sales office.
2. If it is intended to use Clean COLORBOND® XRW steel in an exterior application within 1km of salt marine locations, severe industrial
or abnormally corrosive environments; in areas not washed by rain, or in applications where it will be wholly or partly buried in the
ground, please contact your nearest BlueScope sales office for specialized advice. For selection of the most appropriate Clean
COLORBOND® XRW product, please refer to Technical Bulletins TB1a, TB1b, CTB16, CTB21, CTB22.
3. Customers should use product promptly (within 6 months) to avoid the possibility of storage related corrosion.
4. Finish Coat – the coating applied to the exposed surface of the prepainted coil which is expected to meet the Performance
Requirements.
5. The product is supplied with a nominal 25 unit (60°) gloss Finish Coat.
6. Backing Coat – a thin coating applied to the reverse surface of the prepainted coil. It also gives additional durability to the reverse
surface during the service life of the product, but for aesthetic reasons is not recommended for exposure to sunlight. Performance
Requirements are generally not applicable to backing coats. Where specific Performance Requirements are deemed necessary for
the reverse surface coating, a “double sided” product should be specified, in which case a topcoat of full nominal thickness will be
applied.
7. The minimum internal bend diameters for forming processes to achieve no paint cracking (visible using x 10 magnification) and to
avoid paint adhesion issues are specified by the T-bend flexibility and T-bend adhesion results respectively – where 1T equals the
Total Coated Thickness (TCT) in mm of the material. These results are based on testing at 20-25°C.
8. For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss of ductility
compared with unpainted product. However, minimum strength levels designated by relevant standards will still be applicable.
9. Improper storage or use of non-approved roll-forming lubricants may cause brand transfer and paint blushing, and may adversely
affect colour and long term durability. Product in coil or sheet pack form must be kept dry. If the coil or sheet pack becomes wet, it
must be separated and dried (refer AS/NZS2728 Appendix L, and also Technical Bulletin TB7). Contact nearest BlueScope sales
office on appropriate rollforming lubricants.
10. Values quoted are for panels exposed in accordance with AS/NZS2728. Variations for in-situ performance may occur due complexity
of building design and location.
11. Clean COLORBOND® XRW has good resistance to accidental spillage of solvents such as methylated spirits, white sprit, mineral
turpentine, toluene, and trichloroethylene and dilute mineral acids and alkalis. However, all spillages should be immediately removed
by water washing and drying.
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Reference NSBI/BDV/2023-V/0373
No.
PT. NS BlueScope Indonesia, South Quarter – Tower A, 10th floor Unit E, F, G, H, Jl. RA. Kartini, Kav. 8, CIlandak Barat - Jakarta 12430.
Phone: +62 21 50982030; Fax: +62 21 50982040
1/2
5. PT. NS BlueScope Indonesia is considered to offer the warranty for the building more than
1000 meters (1km) radius from the smelting plant facilities, with the following:
Please note that nothing in this letter creates any legally binding obligation and is only provided
for information purposes.
I trust that this information will assists You, if You have any further information and queries relating
to this matter then please contact the Sales Representative or Technical Marketing at 021-2966
0280.
Thanks for your kind cooperation and attention.
Yours sincerely,
Irfan Fauzie
VP – Sales and Marketing
2/2
ALL PRODUCTS
CAME WITH
FRP GUTTER
V-Sky FRP roof panel provide the perfect green roof
V-SKY PRODUCT SPECIFICATION
solution to meet your building lighting
requirements. Description: The product shall be Zelltech V-sky Glass
Reinforced Polyester Sheeting
Surface Coating: TOP: DuPont Teijin Melinex® Film
UNDER: DuPont Teijin Melinex® Underside Film
Translucent panels provide the perfect green roof solution to meet Resin System: The Resin System shall be............[HPRS, 50FR,
your building lighting requirements; substantially reducing the 25HTH or other]
amount of artificial illumination and electricity needed to light the Product Certificat'n: To AS/NZS 4256.3 : 1994
Production
inside of your building. Manufacturing
Standard: To ISO 9001 : 2008
Profile: The Profile shall be........................
Fiberglass roofing panels are more dimensionally stable than
Weight: The Weight shall be........................[1800, 2400,
competing materials such as PVC or Polycarbonate. Fiberglass
roofing panels can be used over a much broader temperature Colour:
3050, 3660, 4880 or other g/m2]
The Colour shall be........................[CLEAR,
OPAL or other]
Light Emitting Fiberglass Reinforced Plastic
range without concern of warpage, excessive expansion and
contraction or cracking and brittleness commonly associated with
Installation: To be carried out in accordance with the
Australian/New Zealand Design and Installation
PRODUCT INFORMATION
these competing products. of sheet roof and wall cladding products
AS/NZS 1562.3 : 1996 and Zelltech V-sky Roofing
Products Co Ltd Installation and Maintenance
Translucent reinforced corrugated fiberglass skylight panels procedures
are ideal for:
Ÿ Residential awnings over patio decks and windows
Ÿ Pergola and gazebo coverings
Ÿ Carports
Ÿ Restaurant and commercial canopies and walkways.
Ÿ Barn skylights & other agricultural building sklyights
Ÿ Factory building skylights & other industrial buildings
Ÿ Metal building skylights
Ÿ Warehouse skylights, etc.
A PRODUCT OF
Imprint: Reproduction of this brochure in whole or part, the copying or imitation of any illustrations and the imitation of the layout is strictly prohibited. The technical US Tech.
descriptions and dimensions in this brochure, also those imagery and drawings, are-non-binding. Copyright © PT. Cellcius Indoperkasa. Cellcius Skylite Fiberglass 2015. All
rights reserved. Design by Mark Design.
We bring the sun
to your indoors..
Zelltech V-sky fiberglass reinforced plastic
roofing and gutter provide the perfect green roof
solution to meet your sustainable building
lighting and energy saving requirements.
Quality Product is
Why pay for what nature provides for free? Why pay for the
a result of Quality Process
best light that you can have... The Sun
Why V-Sky?
HIGH STRENGTH VERSATILE CHEMICAL & CORROSION
V-Sky panels are strong, V-Sky offers a wide range of RESISTANT
durable and shatter resistant. manufacturing and technical FRP panels remain virtually
Long in-line feeder to output process with less human involvement. Automated & Programmed control panel.
They have a high strength to capabilities to meet specific unaffected in many chemical
modulus ratio and therefore. needs. V-Sky are available in a environments. There’ll be no
wide range of colors, finishes rust, rot, scale or mildew.
GOOD WEATHERING and profiles are adaptable.
CHARACTERISTICS RESILIENT
V-Sky panels have ‘built-in’ UV DIFFUSED LIGHT V-Sky panels are naturally PROJECT APPLICATIONS
and weather protection. TRANSMISSION resilient and withstand large
There is no need to apply V-Sky panels are translucent deflections associated with
costly coatings or film. The panels that provide soft normal load and impact
outer exteriors of V-Sky are diffused transmitted light. conditions without suffering
coated by Dupont Melinex. damage.
Dupont Melinex
Sophisticated Construction
Gel Coat
for a long-life endurance
Fiberglass Matt V-Sky construction is one of a kind, one of the product in the market
that uses high quality material such as Dupont Melinex and
Japan resin
GEL COAT that brings:
Dupont Melinex - Surface smoothness and reflectivity Residential Industrial Public Space
* TYPE 3 - Durability and protection against UV, and any weather
02. FLASHING
MATERIAL SPESIFICATION
RAL
7047
Standard
Paint Coating : AS/NZS 2728:2013 Type 4
Substrate : AS 1397:2011 ; SNI 4096:2007
Mechanical Properties
GUARANTEED
Parameter
G550’ G300’
Yield Strength (Mpa) 550 300
Tensile Strength (Mpa) 550 340
Elongation in 50 mm (% EL) 2 20
Typical Properties
Substrate : Zincalume® XPD Steel G300
Coating Class : AZ 200
Primer Coat : Corrosion inhibitive primer
Finish Coat : Custom formulated system – PVDF (Polyvinylidene Fluoride) coating system
Coating Thickness : 35 micron
Surface Condition : Painted
Gloss : Nominal 25% (600)
Standard
Paint Coating : AS/NZS 2728:2013 Type 3
Substrate : AS 1397:2011, SNI 4096:2007
Mechanical Properties
GUARANTEED
Parameter
G550’ G300’ 340”
Yield Strength (Mpa) 550 300 340
Tensile Strength (Mpa) 550 340 -
Elongation in 50 mm (% EL) 2 20 12
1800 transverse bend (L axis) - 2t -
Prepainted - PP
INDONESIA STANDARD
SNI 4096:2007 Baja lembaran dan gulungan lapis paduan
Aluminium – seng (Bj.L AS)
PRODUCT INFORMATION
ZINCALUME® G550 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
SUBSTRATE
ZINCALUME® G300 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
PRETREATMENT Corrosion resistant proprietary conversion coating
PRIMER COAT Universal corrosion inhibitive primer. Nominal dry film thickness 5µm each side
FINISH COAT Custom formulated PVDF paint system with high performance pigments. Nominal dry film thickness 20µm on
the top or weather side.
BACKING COAT Custom formulated Shadow Grey. Nominal dry film thickness 5µm
COLOUR A range of colours is available. Other specifically required colours may be available on request.
Zincalume® AZ150
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
Guaranteed Minimum
Mechanical Properties
G300 G550
Yield Strength (MPa) 300 550
Tensile Strength (MPa) 340 550
Elongation (% - on 50mm) 20 2
Chemical Properties of Steel Based
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PRODUCT ATTRIBUTES
PROPERTY TEST & EVALUATION METHOD (S) RESULTS
Resistance to Abrasion
Scratch AS2331.4.7 Typically 2000g
Flexibility
T-bend ASTM D4145 Maximum 10T (no cracking). Refer Note 7
Adhesion
Natural well washed exposure (15 years) AS/NZS 1580.457.1 No flaking or peeling. Refer Notes 9 & 10
Resistance to Humidity
Cleveland (500 hours) ASTM D4585; AS/NZS 1580.481.1.9 (Blisters); Blister density: ≤3. Blister size: ≤S2. No loss of
AS 1580.408.4 (Adhesion) adhesion or corrosion
Resistance to Corrosion
Salt spray (1000 hours) AS/NZS2728 (Appendix I), ASTM B117, Blister density: ≤2. Blister size: ≤S3. Undercut
AS2331.3.1, AS/NZS 1580.481.1.9 (Blisters), from score: ≤2mm. No loss of adhesion or
AS1580.408.4 (Adhesion) corrosion. Refer Note 2
Resistance to Colour Change
QUV (2000 hours) ASTM G154 & ASTM D2244 (Colour) ΔE CIELAB 2000: Intermediate colour: ≤ 5 units
Resistance to Chalking
Natural well washed exposure (10 years) AS/NZS 1580.457.1 & AS/NZS 1580.481.1.11 Chalk Rating: ≤4. Refer Notes 9 & 10
(Chalk Method B)
QUV (2000 hours) ASTM G154 & AS/NZS 1580.481.1.11 (Chalk Chalk Rating: ≤4
Method B)
Resistance to Solvents
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Acids
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Alkalis
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Fire
Exposure AS/NZS 1530.3 Ignibility Index: 0 rating in scale of 0-20;
Spread of Flame Index: 0 rating in scale of 0-10;
Heat Evolved Index: 0 rating in scale of 0-10;
Smoke Evolved Index: 0-1 rating in scale of 0-10
Resistance to Heat
Exposure 100°C continuous (500 hours) ASTM D2244 (Colour) Colour change ΔE CIELAB 2000: ≤3 units
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
IMPORTANT NOTES
1. All warranties for a product, if any, are subject to eligibility. Terms and conditions apply. Nothing in this document is intended by
BlueScope to extend, modify or otherwise affect any stated product warranty. To find out more, please contact your nearest
BlueScope sales office.
2. If it is intended to use Clean COLORBOND® XPD steel in an exterior application within 1km of salt marine locations, severe industrial
or abnormally corrosive environments; in areas not washed by rain, or in applications where it will be wholly or partly buried in the
ground, please contact your nearest BlueScope sales office for specialized advice. For selection of the most appropriate Clean
COLORBOND® XPD product, please refer to Technical Bulletins TB1a, TB1b, CTB16, CTB21, CTB22.
3. Customers should use product promptly (within 6 months) to avoid the possibility of storage related corrosion.
4. Finish Coat – the coating applied to the exposed surface of the prepainted coil which is expected to meet the Performance
Requirements.
5. The product is supplied with a nominal 25 unit (60°) gloss Finish Coat.
6. Backing Coat – a thin coating applied to the reverse surface of the prepainted coil. It also gives additional durability to the reverse
surface during the service life of the product, but for aesthetic reasons is not recommended for exposure to sunlight. Performance
Requirements are generally not applicable to backing coats. Where specific Performance Requirements are deemed necessary for
the reverse surface coating, a “double sided” product should be specified, in which case a topcoat of full nominal thickness will be
applied.
7. The minimum internal bend diameters for forming processes to achieve no paint cracking (visible using x 10 magnification) and to
avoid paint adhesion issues are specified by the T-bend flexibility and T-bend adhesion results respectively – where 1T equals the
Total Coated Thickness (TCT) in mm of the material. These results are based on testing at 20-25°C.
8. For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss of ductility
compared with unpainted product. However, minimum strength levels designated by relevant standards will still be applicable.
9. Improper storage or use of non-approved roll-forming lubricants may cause brand transfer and paint blushing, and may adversely
affect colour and long term durability. Product in coil or sheet pack form must be kept dry. If the coil or sheet pack becomes wet, it
must be separated and dried (refer AS/NZS2728 Appendix L, and also Technical Bulletin TB7). Contact nearest BlueScope sales
office on appropriate rollforming lubricants.
10. Values quoted are for panels exposed in accordance with AS/NZS2728. Variations for in-situ performance may occur due complexity
of building design and location.
11. Clean COLORBOND® XPD has good resistance to accidental spillage of solvents such as methylated spirits, white sprit, mineral
turpentine, toluene, and trichloroethylene and dilute mineral acids and alkalis. However, all spillages should be immediately removed
by water washing and drying.
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
INDONESIA STANDARD
SNI 4096:2007 Baja lembaran dan gulungan lapis paduan
Aluminium – seng (Bj.L AS)
PRODUCT INFORMATION
ZINCALUME® G550 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
SUBSTRATE
ZINCALUME® G300 AZ150 steel (Aluminium/Zinc alloy-coated steel) (Refer to Note 8)
PRETREATMENT Corrosion resistant proprietary conversion coating
PRIMER COAT Universal corrosion inhibitive primer. Nominal dry film thickness 5µm each side
FINISH COAT Custom formulated super polyester paint system with high performance pigments. Nominal dry film thickness
20µm on the top or weather side.
BACKING COAT Custom formulated Shadow Grey. Nominal dry film thickness 5µm
COLOUR A range of standard colours is available. Other specifically required colours may be available on request.
Zincalume® AZ150
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
Guaranteed Minimum
Mechanical Properties
G300 G550
Yield Strength (MPa) 300 550
Tensile Strength (MPa) 340 550
Elongation (% - on 50mm) 20 2
Chemical Properties of Steel Based
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
PRODUCT ATTRIBUTES
PROPERTY TEST & EVALUATION METHOD (S) RESULTS
Resistance to Abrasion
Scratch AS2331.4.7 Typically 2000g
Flexibility
T-bend ASTM D4145 Maximum 10T (no cracking). Refer Note 7
Adhesion
Natural well washed exposure (15 years) AS/NZS 1580.457.1 No flaking or peeling. Refer Notes 9 & 10
Resistance to Humidity
Cleveland (500 hours) ASTM D4545; AS/NZS 1580.481.1.9 (Blisters); Blister density: ≤3. Blister size: ≤S2. No loss of
AS 1580.408.4 (Adhesion) adhesion or corrosion
Resistance to Corrosion
Salt spray (1000 hours) AS/NZS2728 (Appendix I), ASTM B117, Blister density: ≤2. Blister size: ≤S3. Undercut
AS2331.3.1, AS/NZS 1580.481.1.9 (Blisters), from score: ≤2mm. No loss of adhesion or
AS1580.408.4 (Adhesion) corrosion. Refer Note 2
Resistance to Colour Change
QUV (2000 hours) ASTM G154 & ASTM D2244 (Colour) ΔE CIELAB 2000: Intermediate colour: ≤ 5 units
Resistance to Chalking
Natural well washed exposure (10 years) AS/NZS 1580.457.1 & AS/NZS 1580.481.1.11 Chalk Rating: ≤4. Refer Notes 9 & 10
(Chalk Method B)
QUV (2000 hours) ASTM G154 & AS/NZS 1580.481.1.11 (Chalk Chalk Rating: ≤4
Method B)
Resistance to Solvents
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Acids
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Alkalis
Exposure ASTM D1308 (3.1.1) & ASTM D2244 (Colour); No discoloration or blistering. Refer Notes 9 & 11
AS/NZS 1580.481.1.9 (Blisters)
Resistance to Fire
Exposure AS/NZS 1530.3 Ignibility Index: 0 rating in scale of 0-20;
Spread of Flame Index: 0 rating in scale of 0-10;
Heat Evolved Index: 0 rating in scale of 0-10;
Smoke Evolved Index: 0-1 rating in scale of 0-10
Resistance to Heat
Exposure 100°C continuous (500 hours) ASTM D2244 (Colour) Colour change ΔE CIELAB 2000: ≤3 units
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
Prepainted - PP
IMPORTANT NOTES
1. All warranties for a product, if any, are subject to eligibility. Terms and conditions apply. Nothing in this document is intended by
BlueScope to extend, modify or otherwise affect any stated product warranty. To find out more, please contact your nearest
BlueScope sales office.
2. If it is intended to use Clean COLORBOND® XRW steel in an exterior application within 1km of salt marine locations, severe industrial
or abnormally corrosive environments; in areas not washed by rain, or in applications where it will be wholly or partly buried in the
ground, please contact your nearest BlueScope sales office for specialized advice. For selection of the most appropriate Clean
COLORBOND® XRW product, please refer to Technical Bulletins TB1a, TB1b, CTB16, CTB21, CTB22.
3. Customers should use product promptly (within 6 months) to avoid the possibility of storage related corrosion.
4. Finish Coat – the coating applied to the exposed surface of the prepainted coil which is expected to meet the Performance
Requirements.
5. The product is supplied with a nominal 25 unit (60°) gloss Finish Coat.
6. Backing Coat – a thin coating applied to the reverse surface of the prepainted coil. It also gives additional durability to the reverse
surface during the service life of the product, but for aesthetic reasons is not recommended for exposure to sunlight. Performance
Requirements are generally not applicable to backing coats. Where specific Performance Requirements are deemed necessary for
the reverse surface coating, a “double sided” product should be specified, in which case a topcoat of full nominal thickness will be
applied.
7. The minimum internal bend diameters for forming processes to achieve no paint cracking (visible using x 10 magnification) and to
avoid paint adhesion issues are specified by the T-bend flexibility and T-bend adhesion results respectively – where 1T equals the
Total Coated Thickness (TCT) in mm of the material. These results are based on testing at 20-25°C.
8. For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss of ductility
compared with unpainted product. However, minimum strength levels designated by relevant standards will still be applicable.
9. Improper storage or use of non-approved roll-forming lubricants may cause brand transfer and paint blushing, and may adversely
affect colour and long term durability. Product in coil or sheet pack form must be kept dry. If the coil or sheet pack becomes wet, it
must be separated and dried (refer AS/NZS2728 Appendix L, and also Technical Bulletin TB7). Contact nearest BlueScope sales
office on appropriate rollforming lubricants.
10. Values quoted are for panels exposed in accordance with AS/NZS2728. Variations for in-situ performance may occur due complexity
of building design and location.
11. Clean COLORBOND® XRW has good resistance to accidental spillage of solvents such as methylated spirits, white sprit, mineral
turpentine, toluene, and trichloroethylene and dilute mineral acids and alkalis. However, all spillages should be immediately removed
by water washing and drying.
PT NS BLUESCOPE INDONESIA
BRI II Building 9th floor suite 902, Jl. Jend. Sudirman Kav 44 – 46 Jakarta 10210. Tel: +62 21 5785 4150 Fax: +62 21 5785 4151 Website: www.bluescope.co.id
�i ..- �$�;l;ft1/EJz�l!!i/lUI�
" �/·· PAINTED & NYLON HEAD SCREW
#
ss f
;;-
,; ,t
,: �
.;;
t
.A. *
5ii� � ffi �H�l!!i,ljgfl�
DACROTIZED SELF-DRILLING SCREW
Mechanical Properties
Fastener Strength
Shear strength Shear strength Shear strength
Diameter Threads per inch
(N) (N) (N)
12 G 14 9000 N 155000 N 13.8 Nm
(Tested by National Association of Testing Authorities, Australia)
Chemical Properties
Gasket Rubber
Special formulation of EPDM, ethylene propylene (diene) polymer, NATA (National
Association Association of Testing Authorities) Australia accredited laboratory testing.
- Anti-aging
- Ozone resistance
- UV radiation resistance
- High and low temperature resistance (-30oC – 115oC)
- Good resilience
- Good compressive/tensile strength
- Non-conductive
Fastener Coating Material
04. DOWNSPOUT
l=IUCIKA
RUCIKA
Standard
STANDARD
RUCIKASTANDARD
RUCIKA STANDARD is made of uPVC (unplasticized polyvinyl chloride) polymer
material which has many advantages compared to other plastic polymers, such as:
corrosion resistance, strength, light weight, easy connection and maintenance.
--
AW CLASS
Diameter
Thickness (mm) Lenght (meter) Connection System
1/2 22 1,50 4 SC
3/4 26 1,80 4 SC
1 32 2,00 4 SC
1¼ 42 2,30 4 SC
1½ 48 2,30 4 SC
2 60 2,30 4 SC
2½ 76 2,60 4 SC
3 89 3,10 4 SC
4 114 4,10 4 SC
5 140 5,40 4 SC
6 165 6,40 4 SC
8 216 8,30 4 SC
10 267 10,30 4 SC
12 318 12,20 4 SC
--
Diameter
D CLASS
Diameter
Thickness (mm) Lenght (meter) Connection System
1¼ 42 1,30 4 SC
1½ 48 1,30 4 SC
2 60 1,30 4 SC
2½ 76 1,40 4 SC
3 89 1,60 4 SC
4 114 2,00 4 SC
5 140 2,60 4 SC
6 165 3,00 4 SC
8 216 4 20 4 SC
10 267 5 20 4 SC
12 318 6,20 4 SC
SC: Solvent Cement ( glue connection )
STANDARD
Coefficient of linear
8 x 10-2 mm/m.°C
expansion
Thermal conductivity = 0,15 W/m.°C
Modulus of elasticity = 3000 N/mm2
1. clean the dirt on the surface of the spigot
Surface resistance > 10 12 Ohm
L and socket with cleaner
System Application
2.Measure the depth of the socket and mark it
with a marker on the spigot
Rucika manufactures suitable uPVC pipes
suitable for:
1. clean water channels
2. sewer Channel
3. waste channel
4. Irrigation canal 3.Apply enough RUGlue pvc pipe glue on the
5. Ventilation pipe surface of the socket and continue
Material Characteristic
4.connect immediately and the connection position
is held for a moment so that it does not change
Quality Standard
0 PT WAHANA DUTA JAVA RUCIKA
I
l
h
Alia Building, t Floor
JI. M.I. Ridwan Rais 10-18 (Gambir)
Rucika Standard refers to JIS and
Jakarta 10110, Indonesia.
[ ISO standar. Phone: (021) 386 7717
Fax: (021) 386 7686
www.rucika.co.id
01/2018
05. GUTTER
GUTTER SPESIFICATION
GUTTER SPECIFICATION
System : Bolt System
Eff. Width : 200 mm
Height : 200 mm
MATERIAL SPESIFICATION
Material : V-Sky FRP
Color : Slate Grey Opaque
Thickness : 3.00 mm BMT