TDS-11S SIEMENS SERIES 70 DRIVE (WITH CUVC CONTROL)
LISTING OF INVERTER PARAMETERS
VIEW PAR. NO. IND. PARAMETER DESC. VALUE(Units) COMMENTS YES P050 - Language 1 Language (1=English) YES P053 - Parameter Access 6 Access for Parameters YES P060 2 - Menu Select 0 Parameter Menu (7 = Free Access) P068 0 Output Filter 0 No Output filter P070 - Order No. 6SE70 38-6U.6. MLFB: Drive Size 128 P071 - Line Volts 780V Rated Drive Voltage P072 - Rated Drive Amps 860.0A Rated Drive Current P073 - Rated Drive Power 630.0 kW Rated Drive Power P075 1 X (magnet,d)tot 150.0% (Default) P075 2 X (magnet,d)tot 150.0% (Default) P076 1 X (magnet,q)tot 150.0% (Default) P076 2 X (magnet,q)tot 150.0% (Default) P095 1 Type of Motor 11 NEMA Induction Motor P095 2 Type of Motor 11 NEMA Induction Motor P100 1 Control Mode 4 Speed Regulation P100 2 Control Mode 3 Frequency Regulation P101 1 Motor Rated Volts 575V Motor Nameplate P101 2 Motor Rated Volts 575V Motor Nameplate YES P102 1 Motor Rated Current 732.0A Motor Nameplate YES P102 2 Motor Rated Current 732.0A Motor Nameplate P103 1 Motor Magn Current 0 Typ = 22.3% P103 2 Motor Magn Current 0 Typ = 22.3% P104 1 Motor Power Factor 0.87 Motor Nameplate P104 2 Motor Power Factor 0.87 Motor Nameplate YES P105 1 Motor Rated Power 800.0 Hp Motor Nameplate YES P105 2 Motor Rated Power 800.0 Hp Motor Nameplate P106 1 Motor Rated Efficiency 92% Motor Nameplate P106 2 Motor Rated Efficiency 92% Motor Nameplate P107 1 Motor Rated Frequency 39.2 Hz Motor Nameplate P107 2 Motor Rated Frequency 39.2 Hz Motor Nameplate P108 1 Motor Rated Speed 1155 1/min Motor Nameplate P108 2 Motor Rated Speed 1155 1/min Motor Nameplate P109 1 Motor #Pole Pairs 2 Motor Nameplate P109 2 Motor #Pole Pairs 2 Motor Nameplate YES P113 1 Motor Rated Torque 4934.0 Nm Calculated From Motor Nameplate YES P113 2 Motor Rated Torque 4934.0 Nm Calculated From Motor Nameplate YES P115 3 - Calc Motor Model 0 Auto Tune (P115=2, 4, 5) P116 1 Start-Up Time 0.20 s typ Auto Tuned P116 2 Start-Up Time 0.21 s typ Auto Tuned P120 1 Main Reactance 380.9 typ (Auto tuned) P120 2 Main Reactance 388.3 typ (Auto tuned) P121 1 Stator Resistance 3.43% typ (Auto tuned) P121 2 Stator Resistance 3.38% typ (Auto tuned) P122 1 Total Leakage React 31.15% typ (Auto tuned) P122 2 Total Leakage React 31.21% typ (Auto tuned) P127 1 RotResistTmpFact 80.7% typ Resistance Temp Factor (Auto tuned) P127 2 RotResistTmpFact 78.6% typ Resistance Temp Factor (Auto tuned) YES P128 1 Imax 1169.5 A Maximum current setpoint (1.5 x P102) YES P128 2 Imax 1169.5 A Maximum current setpoint (1.5 x P102) P130 1 Select Motor Encoder 11 11 = Encoder P130 2 Select Motor Encoder 10 10 = No encoder
16:29 SHEET 2 OF 13 VIEW PAR. NO. IND. PARAMETER DESC. VALUE(Units) COMMENTS P151 1 Encoder Pulse # 1024 Number of encoder pulses P151 2 Encoder Pulse # 1024 Number of encoder pulses YES P215 1 Max dn/dt 8.10 Hz Speed Error Allowed YES P215 2 Max dn/dt 8.10 Hz Speed Error Allowed P216 1 Smooth n/f (FWD) 0.0 ms typ Smoothing Value for Speed Reg (Auto tuned) P216 2 Smooth n/f (FWD) 4.8 ms typ Smoothing Value for Speed Reg (Auto tuned) P221 1 Smooth n/f (Set) 4 ms (Default) P221 2 Smooth n/f (Set) 4 ms (Default) P222 1 Source of n/f (act) 0 (Default) P222 2 Source of n/f (act) 0 (Default) P223 1 Smooth n/f (act) 4 ms typ (Auto tuned) P223 2 Smooth n/f (act) 0 ms typ (Auto tuned) P233 1 n/f Reg. Adapt.1 0.0% (Default) P233 2 n/f Reg. Adapt.1 0.0% (Default) P234 1 n/f Reg. Adapt.2 100.0% (Default) P234 2 n/f Reg. Adapt.2 100.0% (Default) P235 1 n/f-reg. Gain 1 2.9 typ Porport Gain of Speed Regulator (Auto tuned) P235 2 n/f-reg. Gain 1 1.6 typ Porport Gain of Speed Regulator (Auto tuned) P236 1 n/f-reg. Gain 2 2.9 typ Porport Gain of Speed Regulator (Auto tuned) P236 2 n/f-reg. Gain 2 1.6 typ Porport Gain of Speed Regulator (Auto tuned) P240 1 n/f Reg. Time 134 ms typ Integral time of speed controller (Auto tuned) P240 2 n/f Reg. Time 258 ms typ Integral time of speed controller (Auto tuned) YES P259 1 Max Regen Power -30.0% Maximum allowed regenerative power. YES P259 2 Max Regen Power -30.0% Maximum allowed regenerative power. P273 1 Smooth Isq (set) 7 ms typ Torque smoothing time constant (Auto tuned) P273 2 Smooth Isq (set) 7 ms typ Torque smoothing time constant (Auto tuned) P274 1 Isq (set) grad. 2928.0 A typ Rise limitation for Isq setpoint (Auto tuned) P274 2 Isq (set) grad. 2928.0 A typ Rise limitation for Isq setpoint (Auto tuned) P283 1 Current Reg Gain 0.395 typ Gain of the PI current controller (Auto tuned) P283 2 Current Reg Gain 0.395 typ Gain of the PI current controller (Auto tuned) P284 1 Current Reg Time 6.4 ms typ Adjust. time of the PI controller (Auto tuned) P284 2 Current Reg Time 6.4 ms typ Adjust. time of the PI controller (Auto tuned) P287 1 SmoothDCBusVolts 9 DC link bus V smoothing time const (Default) P287 2 SmoothDCBusVolts 9 DC link bus V smoothing time const (Default) P291 1 Fsetp Flux (set) 100.0% Flux setpoint from rated rotor flux (Default) P291 2 Fsetp Flux (set) 100.0% Flux setpoint from rated rotor flux (Default) YES P295 1 Efficiency Optim 50.0% Better Control at Reduced Load YES P295 2 Efficiency Optim 50.0% Better Control at Reduced Load P303 1 Smooth Flux (Set) 20 ms typ Flux setpt smoothing time const (Auto tuned) P303 2 Smooth Flux (Set) 20 ms typ Flux setpt smoothing time const (Auto tuned) P305 1 FieldWeakRegTime 150 ms Field weakening time for PI contoller (Default) P305 2 FieldWeakRegTime 150 ms Field weakening time for PI contoller (Default) P313 1 f(cEMF Mod) 3.93 Hz typ Frequency of switch for models (Auto tuned) P313 2 f(cEMF Mod) 3.93 Hz typ Frequency of switch for models (Auto tuned) P314 1 f(cEMF->AMP-mod) 50.0% Frequency of switch for models (Default) P314 2 f(cEMF->AMP-mod) 50.0% Frequency of switch for models (Default) P315 1 cEMF Reg Gain 0.156 typ PI for counter EMF model (Auto tuned) P315 2 cEMF Reg Gain 0.300 typ PI for counter EMF model (Auto tuned) P316 1 cEMF Reg Time 52.0 ms typ Integral time for counter EMF (Auto tuned) P316 2 cEMF Reg Time 54.0 ms typ Integral time for counter EMF (Auto tuned) P338 1 Common Mode Comp 3.00 us Edge pulse modulator compensate (Default) P338 2 Common Mode Comp 3.00 us Edge pulse modulator compensate (Default) P338 3 Common Mode Comp 3.00 us Edge pulse modulator compensate (Default) P338 4 Common Mode Comp 3.00 us Edge pulse modulator compensate (Default)
16:29 SHEET 3 OF 13 VIEW PAR. NO. IND. PARAMETER DESC. VALUE(Units) COMMENTS P338 5 Common Mode Comp 3.00 us Edge pulse modulator compensate (Default) P338 6 Common Mode Comp 3.00 us Edge pulse modulator compensate (Default) P339 1 ModSystemRelease 0 Freq system type to release P338 (Default) P339 2 ModSystemRelease 0 Freq system type to release P338 (Default) P340 1 Pulse Frequency 2.5 kHz Drive Carrier Frequency (Default) P340 2 Pulse Frequency 2.5 kHz Drive Carrier Frequency (Default) P342 1 Max ModulatDepth 96.0% Max modulation depth of modulator (Default) P342 2 Max ModulatDepth 96.0% Max modulation depth of modulator (Default) P344 1 ModDepth Headroom 0.0% Modulator headroom depth (Default) P344 2 ModDepth Headroom 0.0% Modulator headroom depth (Default) P347 1 ON VoltsCompens. 1.1 V typ IGBT voltage diff compensation (Auto tuned) P347 2 ON VoltsCompens. 1.1 V typ IGBT voltage diff compensation (Auto tuned) P348 - Dead Time Comp 0 Select deadtime Comp,0=off (Auto tuned) P349 - T(DeadtimeComp.) 2.55us Gate unit intrlock compens time (Auto tuned) YES P350 - Ref Amps 732.0 A Set to P102 (Motor Rated Current) P351 - Ref Volts 575 V Set to P101 (Motor Rated Voltage) P352 - Ref Frequency 81.50 Hz Motor Nameplate P353 - Ref Speed 2400 1/min Motor Nameplate YES P354 - Ref torque 4934.00Nm Set to P113 (Motor Rated Torque) P357 - Sampling time 1.2 ms Base Sampling Time YES P360 1 Select User Parameter P060 Always select P060 (Menu Access) P360 2 Select User Parameter P053 Always select P053 (Parameter access) P360 3 Select User Parameter P358 Always select P358 (Key unlock parameter) P360 4 Select User Parameter r001 Select Drive Status. P360 5 Select User Parameter r002 Select Rotational Frequency P360 6 Select User Parameter r003 Select Output Volts P360 7 Select User Parameter r004 Select Output Amps P360 8 Select User Parameter r005 Select Output Power P360 9 Select User Parameter r006 Select DC Bus Volts P360 10 Select User Parameter r007 Select Motor Torque P360 11 Select User Parameter r008 Select Motor Utilization P360 12 Select User Parameter r011 Select Active Motor Data Set P360 13 Select User Parameter r012 Select Active BICO Data Set P360 14 Select User Parameter r013 Select Active Function Data Set P360 15 Select User Parameter r014 Select Set Point Speed P360 16 Select User Parameter r015 Select Speed Actual Input P360 17 Select User Parameter P050 Select Language P360 18 Select User Parameter P102 Select Motor Rated Amps P360 19 Select User Parameter P105 Select Motor Rated Power P360 20 Select User Parameter P113 Select Motor Rated Torque P360 21 Select User Parameter P115 Select Motor Calculation (Auto Tune) P360 22 Select User Parameter P128 Select Imax P360 23 Select User Parameter P215 Select max. dn/dt P360 24 Select User Parameter P259 Select Max Regen Power P360 25 Select User Parameter P295 Select Efficiency Optim P360 26 Select User Parameter P350 Select Reference Amps P360 27 Select User Parameter P354 Select Reference Torque P360 28 Select User Parameter P401 Select Fixed Setpoint 1 P360 29 Select User Parameter r419 Select # of Active Fault Setpoints P360 30 Select User Parameter P492 Select FixTorque 1 Set P360 31 Select User Parameter r496 Select Fix Torque 1 P360 32 Select User Parameter r497 Select Actual Upper Torque Limit P360 33 Select User Parameter P498 Select FixTorq 2 Set P360 34 Select User Parameter r502 Select Fix Torque 2
16:29 SHEET 4 OF 13 VIEW PAR. NO. IND. PARAMETER DESC. VALUE(Units) COMMENTS P360 35 Select User Parameter r550 Select Control Word 1 P360 36 Select User Parameter r551 Select Control Word 2 P360 37 Select User Parameter r552 Select Status Word 1 P360 38 Select User Parameter r553 Select Status Word 2 P360 39 Select User Parameter P590 Select Src BICO Dset P360 40 Select User Parameter P602 Select Excitation time P360 41 Select User Parameter P640 Select Src Analog Out P360 42 Select User Parameter P643 Select CU AnalogOutGain P360 43 Select User Parameter P644 Select CU- AnalogOutOff P360 44 Select User Parameter r782 Select Last 8 Fault Trip Times P360 45 Select User Parameter r783 Select n/f actual (r218) at time of last trip P360 46 Select User Parameter r784 Select n/f actual/second at time of last trip P360 47 Select User Parameter r785 Select actual torque current at time of trip P360 48 Select User Parameter r786 Select actual converter out V at time of trip P360 49 Select User Parameter r787 Select Control Status at time of trip P360 50 Select User Parameter r825 Select Operating Hours (Inverter Pulsing) P360 51 Select User Parameter r947 Select Last 8 Faults P360 52 Select User Parameter r949 Select Last 8 Fault Values P360 53 Select User Parameter P971 Select EEPROM Saving P360 54 Select User Parameter U002 Select Fixed Setpt 18 (Meter Torque Scaling) P361 - OP1s Backlight 0 0= Always On P366 - Select FactSet 1 Select Factory Setting (Default) P368 - Select Setp Src 1 Analog Input & Terminal Strip (Default) P370 - Quick Param 0 P370=1 Will Factory DEFAULT Parameters!!!! P375 - Ground Flt Test 0 Blocked (Default) P382 1 Motor Cooling 1 1 = Forced Vent P382 2 Motor Cooling 1 1 = Forced Vent P383 1 Mot ThermT-Const 1800 s Max Time Allowed in Stall = 30 min. P383 2 Mot ThermT-Const 1800 s Max Time Allowed in Stall = 30 min. P401 1 Fixed Setpoint 1 0.00% Additional Drill Speed P401 2 Fixed Setpoint 1 10.00% Spin Speed Set to 10% of Rated Speed P401 3 Fixed Setpoint 1 5.00% Torque Speed Set to 5% of Rated Speed P421 - MOP (max) 100.0% Upper Limit of OP1S (Default) P422 - MOP (min) 0.0% Lower Limit of OP1S (Default) P423 - Src MOP inv. 2111 BICO for Direction Change on OP1S P425 - Conf MOP 0110 Configuration of MOP P426 - StartValue MOP 0.0% MOP Starting Value P427 - Src Set MOP 0 BICO Source for MOP Use (Default) P428 - Src SetV MOP 0 BICO Source for MOP Set Value (Default) P429 - Src Auto SetP 0 BICO Source for MOP Auto Setpt (Default) P430 - Src Manual/Auto 0 BICO Source for Manual/Auto Switching P433 1 Src AddSetpoint1 41 BICO to Set Spin, Torque, and Speed P433 2 Src AddSetpoint1 0 BICO to Set Spin, Torque, and Speed P434 1 Scale Add Setpoint 100.00% Gain for Additional Setpoint 1 (Default) P434 2 Scale Add Setpoint 100.00% Gain for Additional Setpoint 1 (Default) P434 3 Scale Add Setpoint 100.00% Gain for Additional Setpoint 1 (Default) P443 1 Src MainSetpoint 3002 BICO for Main Setpoint P443 2 Src MainSetpoint 58 BICO for Main Setpoint P444 1 Scale Main Setp 100.00% Scaling factor for Main Setpoint (Default) P444 2 Scale Main Setp 100.00% Scaling factor for Main Setpoint (Default) P444 3 Scale Main Setp 100.00% Scaling factor for Main Setpoint (Default) P445 1 Base Setpoint 0.0% Basic Setpoint (Added to Main Setpoint)(Def) P445 2 Base Setpoint 0.0% Basic Setpoint (Added to Main Setpoint)(Def) P445 3 Base Setpoint 0.0% Basic Setpoint (Added to Main Setpoint)(Def)
16:29 SHEET 5 OF 13 VIEW PAR. NO. IND. PARAMETER DESC. VALUE(Units) COMMENTS P448 - Jog Setp 1 10.00% Jogging Setpoint 1 (Default) P449 - Jog Setp 2 20.00% Jogging Setpoint 2 (Default) P452 1 n/f(max, FWD Spd) 100.0% Max Setpoint for CW (Forward) Rotating Field P452 2 n/f(max, FWD Spd) 100.0% Max Setpoint for CW (Forward) Rotating Field P452 3 n/f(max, FWD Spd) 100.0% Max Setpoint for CW (Forward) Rotating Field P453 1 n/f(max,REV Spd) -50.00% Max Setpoint for CCW(Reverse) Rotating Field P453 2 n/f(max,REV Spd) -50.00% Max Setpoint for CCW(Reverse) Rotating Field P453 3 n/f(max,REV Spd) -50.00% Max Setpoint for CCW(Reverse) Rotating Field P457 1 Min setp 0.0% Minimum Setpoint of the Drive (Default) P457 2 Min setp 0.0% Minimum Setpoint of the Drive (Default) P457 3 Min setp 0.0% Minimum Setpoint of the Drive (Default) P462 1 Accel. Time 5.0 Acceleration Time (P463) From 0 to 100% P462 2 Accel. Time 5.0 Acceleration Time (P463) From 0 to 100% P462 3 Accel. Time 5.0 Acceleration Time (P463) From 0 to 100% P463 1 Accel. Time Unit 0 0 = Seconds P463 2 Accel. Time Unit 0 0 = Seconds P463 3 Accel. Time Unit 0 0 = Seconds P464 1 Decel. Time 2 Deceleration Time (P465) From 100 to 0% P464 2 Decel. Time 2 Deceleration Time (P465) From 100 to 0% P464 3 Decel. Time 2 Deceleration Time (P465) From 100 to 0% P465 1 Decel. Time Unit 0 0 = Seconds P465 2 Decel. Time Unit 0 0 = Seconds P465 3 Decel. Time Unit 0 0 = Seconds P466 1 Decel. Time OFF3 2.0 s Keypad "quickstop" from 100% to standstill P466 2 Decel. Time OFF3 0.0 s Keypad "quickstop" from 100% to standstill P467 1 ProtRampGen Gain 2.9 typ Acceleration Time (P462) Gain Factor(AutoTn) P467 2 ProtRampGen Gain 1.0 Acceleration Time (P462) Gain Factor (Def) P467 3 ProtRampGen Gain 1.0 Acceleration Time (P462) Gain Factor (Def) P468 - Rgen Round Type 0 Mode for Ramp Function Rounding (Default) P469 1 Ramp StartSmooth 0.50 s Initial Rounding Up Time for Ramp Func (Def) P469 2 Ramp StartSmooth 0.50 s Initial Rounding Up Time for Ramp Func (Def) P469 3 Ramp StartSmooth 0.50 s Initial Rounding Up Time for Ramp Func (Def) P470 1 Ramp End Smooth 0.50 s Final Rounding Up Time for Ramp Func (Def) P470 2 Ramp End Smooth 0.50 s Final Rounding Up Time for Ramp Func (Def) P470 3 Ramp End Smooth 0.50 s Final Rounding Up Time for Ramp Func (Def) P471 1 Scale Torq (PRE) 100.0% Gain of the n/f controller precontrol (Default) P471 2 Scale Torq (PRE) 100.0% Gain of the n/f controller precontrol (Default) P475 - Ramp Limitation 0.0% "0.0" Deactivates Ramp-Func Tracking (Def) P476 - RampGen Act Hyst 1.0% Hysteresis for "Rmp-Func Gen Active" msg. P492 1 FixTorque 1 Set 100.0% Forward Maximum Drill Torque P492 2 FixTorque 1 Set 10.0% Forward Spin Torque P492 3 FixTorque 1 Set 133.0% Maximum Make-up Torque (Forward) P493 1 Src Fixtorque 1 3003 BICO Source for Upper Torque Limitation P493 2 Src Fixtorque 1 170 BICO Source for Upper Torque Limitation P494 1 FixTorque 1 Gain 100.00% Scaling Factor for Upper Torque Limitation P494 2 FixTorque 1 Gain 100.00% Scaling Factor for Upper Torque Limitation P494 3 FixTorque 1 Gain 100.00% Scaling Factor for Upper Torque Limitation P498 1 FixTorque 2 Set -100.00% Reverse Maximum Drill Torque P498 2 FixTorque 2 Set -10.00% Reverse Spin Torque P498 3 FixTorque 2 Set -200.00% Maximum Breakout Torque (Reverse) P499 1 Src FixTorque 2 3005 BICO Source for Lower Torque Limit P499 2 Src FixTorque 2 171 BICO Source for Lower Torque Limit P500 1 Scale TorqLim2 100.00% Scaling Factor for Lower Torque Limit (Def) P500 2 Scale TorqLim2 100.00% Scaling Factor for Lower Torque Limit (Def)
16:29 SHEET 7 OF 13 VIEW PAR. NO. IND. PARAMETER DESC. VALUE(Units) COMMENTS P578 2 Src MotSSet Bit0 3402 BICO Src for Motor Data Set (cw2,bit 18) P579 1 Src MotSSet Bit1 0 BICO Src for Motor Data Set (cw2,bit 19)(Def) P579 2 Src MotSSet Bit1 0 BICO Src for Motor Data Set (cw2,bit 19)(Def) P590 - Src BICO Dset 0 Set PLC or OP1S Control (0=PLC) P602 1 Excitation Time 0.20 s Wait Time Before Releasing Frequency P602 2 Excitation Time 0.20 s Wait Time Before Releasing Frequency P603 1 De-MagnetizeTime 3.00 s Time to DE-excite Motor (Auto Tuned) P603 2 De-MagnetizeTime 3.00 s Time to DE-excite Motor (Auto Tuned) P640 1 Src AnaOut 148 BICO for Analog 1 Out (Speed) P640 2 Src AnaOut 24 BICO for Analog 1 Out (Torque) P643 1 CU AnalogOutGain 10.00 V Porportional Gain for Analog Outputs (Def) P643 2 CU AnalogOutGain 10.00 V Porportional Gain for Analog Outputs (Def) P644 1 CU--AnalogOutOFF 0.00 V Offset Voltage for P643 Analog Outs (Def) P644 2 CU--AnalogOutOFF 0.00 V Offset Voltage for P643 Analog Outs (Def) P652 1 Src DigOut2 122 Undervoltage Fault (Status Word 1, Bit 11) P652 2 Src DigOut2 122 Undervoltage Fault (Status Word 1, Bit 11) P722 1 CB/TB TlgOFF 10 ms Fault if No Communication for 10 ms (Def) P722 2 CB/TB TlgOFF 10 ms Fault if No Communication for 10 ms (Def) P734 1 SrcCB/TBTrnsData 32 Status Word 1(To PLC) P734 2 SrcCB/TBTrnsData 467 Speed to Meter (To PLC) P734 3 SrcCB/TBTrnsData 33 Status Word 2 (To PLC) P734 4 SrcCB/TBTrnsData 468 Torque to Meter (To PLC) P734 5 SrcCB/TBTrnsData 170 Spin Torque (To PLC) P734 6 SrcCB/TBTrnsData 250 Fault Number (To PLC) P952 - # of Faults 7 Number of Stored Fault Trips P970 - Factory Setting 1 P970=0 Will Factory DEFAULT Parameters!!!! P971 - EEPROM Saving 0 Save Parameters(Ram To EEPROM)(P971=1) U001 1 FixSetp 17 95.00% RPM Scaling (For VDC Meter) U001 2 FixSetp 17 95.00% RPM Scaling (For VDC Meter) U001 3 FixSetp 17 95.00% RPM Scaling (For VDC Meter) U002 1 fixSetp 18 62.58% Torque Scaling (For VDC Meter) U002 2 fixSetp 18 62.58% Torque Scaling (For VDC Meter) U002 3 fixSetp 18 62.58% Torque Scaling (For VDC Meter) U107 1 Src Conn Mult1 491 Multipliers for RPM Meter U107 2 Src Conn Mult1 401 Multipliers for RPM Meter U108 1 Src Conn Mult2 492 Multipliers for Torque Meter U108 2 Src Conn Mult2 402 Multipliers for Torque Meter U117 - Src ConnAbsV1 148 BICO Source for 1st Abs Value Generator U118 - Mode ConnAbsV1 1 Mode Sel for Ist Abs Value Gen (1=| Signal |) U119 - SmoothConAbsV1 0 ms Smoothing Time Const for 1st Abs Val Gen U120 - Src ConnAbsV2 24 BICO Source for 2nd Abs Value Generator U121 - Mode ConnAbsV2 1 Mode Sel for 2nd Abs Value Gen (1=| Signal |) U122 - SmoothConAbsV2 0 ms Smoothing Time Const for 2nd Abs Val Gen U950 031 Sampling Times1 2 Sampling time U950 032 Sampling Times1 2 Sampling time U950 075 Sampling Times1 2 Sampling time U951 004 Sampling Times2 2 Sampling time U951 059 Sampling Times2 2 Sampling time U952 047 Sampling Times3 2 Sampling time