SERVICE MANUAL
REFRIGERATOR CONTENTS
1. PRECAUTION......................................................................1
2. PRODUCT SPECIFICATION...............................................2
3. STRUCTURE.......................................................................3
4. SCHEMATIC- DIAGRAM......................................................6
8. TROUBLE -SHOOTING.....................................................12
1 -1-1. Prior to servicing, be sure to disconnect the product from its electrical power source by removing the
products eletrical plug from the wall receptacle to preclude the possibility of resultant presonal injury
and / or property damage.
1-1-2. Never attempt to modify or bypass circuit connections in ways not recommended by the manufacturer.
1-1-3. Do not use any extension or double adaptors.
1-1-4. For person safety, this appliance must be properly grounded.
This refrigerator should not be grounded with a telephone line, gas pipe etc.
1 -2-1. In case of article No.1 and starting capacitor ( itself only ) do not supply power in order to check for
eletrical charge and discharge for more than two minutes. When power is supplied for more than two
minutes, the insulation inside the capacitor may be broken. When it is impossible to finish the test
within two minutes, wait for about 30 minutes, and then check again.
1-2-2. When replacing the relay connected to the compressor terminal pin, be sure to pull it off straight and
push it on straight, Swaying the relay side-to-side or up and down, may cause damage to the
compressor terminal pin and / or the relay.
1-2-3. Wait more than 5 minutes to re-start the refrigerator after you stop it once.
If you plug in the refrigerator immediately after you pull the plug, you may not be able to start it again.
! : This is safety-related information on the A/ C power circuits and parts used in the refrigerator.
: This is the information required for repairing the refrigerator.
-1-
2.PRODUCT SPECIFICATION
Capacity 125L
Width 511
Net Depth
Dimensions 578
(mm)
Height 850
Net weight(Kg) 40
Refrigerant R-134a,50g
Temperature control COMPUTER
Cabinet insulation
Foam Polyurethane Foam(141b)
Door insulation
Liner/Door panel ABS
-2-
3.STRUCTURE
3-1.DESCRIPTION OF COMPONENTS
1 2
1 TOP TABLE
2 PANEL DISPLAY
3 SHELF WIRE-UPP
4 SHELF WIRE-LOW
5 FOOT
-3-
3-2.PRODUCT INSTALLATION
A
B
C
D F
E
MODEL A B C D E F G I
-4-
3-3.CIRCULATION OF REFRIGERANT
蒸发器
压缩机
干燥过滤器
毛细管
25%银焊条焊接
2%银焊条焊接
-5-
4.SCHEMATIC DIAGRAM
4-1.Circuit Diagram
SENSOR WHT
DISPLAY BOARD
GRY BRN AC230V/50HZ
WHT Y/GRN
POWER BOARD
EARTH
BLU
RED RED
LAMP PCB
LAMP
S/BLU RED
BLK
COMPRESSOR
S
3 1
M C
1
M 2
Y/GRN
O/L PROTECTOR
P.T.C RELAY
4-2.Object Diagram
PANEL PCB
TRANS
POWER-
FORM MAIN PCB
POWER SUPPLY CORD
EARTH
STARTING
RELAY
COMPRESSOR OVERLOAD
PROTECTOR
-6-
5.SPECIFICATIONS OF MAJOR FUNCTIONAL PARTS
MODEL D130Q-LIZ/SJ2
COMPRESSOR
OUT PUT/STARTING TYPE RSIR
POSISTOR J531Q35E470M355-2
ELECTRICAL MODEL 4TM166SFBYY-53
PARTS OVERLOAD P
ROTECTOR CLOSE TEMP/OPEN TEMP 61 C/135 C
-7-
6.OPERATING PRINCIPLE OF MAJOR COMPONENTS,AND
INSPECTION METHOD
6-1.Compressor Motor
Operating principle Inspection method
1) Measure the resistance of each winding of the
The compressor motor, mounted directly to the compressor.
compressor and located inside a sealed steel a. Disconnect the power cord.
case, has two windings. b. Remove the relay from the compressor.
One is a start winding and the other a run winding. C. Measure the resistance of each winding.
The windings are connected together internally,
forming a common connection. A lead is connected A. The highest resistance value is the measurement of
to each of the windings, and to the common the "start" and "run" terminals whose windings are
connection. These three leads are then connected connected in series.
to glass-sealed terminals that extend through the
compressor case. B. The lowest resistance value is the measurement of
The terminals are clustered in al trangle ( pyramid ) the "run" and "common" terminals.
pattern and, reading from left to right, are identified:
Start, Common and Run. C. The mid-level resistance
value is the measururement
of the "start" and "common"
terminals.
B + C = A
Compressor Windings
-8-
6-3.Relay
Operating principle Inspection method
The relay momentarily energizes the start winding to
start the rotation of the compressor motor.
Most later refrigerator models use a solid state type
relay.
Unlike the mechanical type relay, the solid state relay
has no coil and no moving contacts.
This relay consists of a small solid state wafer that has
a low resistance at room temperature.
The wafer is positioned between electrical terminals
that connect to the compressor terminals.
-9-
7.HOW TO REPLACE MAJOR COMPONENTS
Gaseous refrigerant in high temperature and in high pressure so radiates evaporation latent heat
CONDENSER: absorbed from evaporator surrounding during passing through condenser and compression heat
due to refrigerant gas compression to surrounding of condenser that refrigerant becomes liquid
in high pressure.
In order to prevent that moisture and foreign substances resided inside every parts during
refrigeration cycle assembling is so included among refrigerant gas that it chokes the exit of inlet
DRYER: of capillary, dryer has drying substances (molecular sieves) and filter inside it which absorbs or
purify them.
Regulates and/or keeps(in specified low)refrigerant flow rate so that maintains constant pressure
drop from wire condenser to evaporator.
Capillary tube:
Liquid referigerant passed through capillary so expand in evaporator that it becomes low
temperature and low pressure to absorb heat around evaporator, so that it chills surrounding air
Evaporator: and at that time liquid refrigerant becomes gaseous.
- 10 -
7-3. Steps for replacing door panel.
1) Remove the screws fastening the door panel.
Then, door panel can replaced.
- 11 -
8. TROUBLE - SHOOTING
8-1. Compressor does not run at all (Does not cool at all)
Cause What to be checked Correction
Erroneous plug cord inserting Check plug cord inserting Insert plug cord into outlet correctly.
Fault relay assembly. Check conduction of overload relay. Replace if overload relay is not conductive.
Fault main pcb Check conduction of main pcb. Replace the pcb.
8-3. Compressor runs normally but inside temprature does not drop at all.
Cause What to be checked Correction
Faulty compressor-evaporator After continuing operation for over Replace Compressor-evaporator unit.
unit. 20minutes, let a drop of water fall onto
evaporator and see if it becomes frozen.
8-4. Compressor runs normally but inside temprature does not drop at a sufficiently low level.
Cause What to be checked Correction
Check for gaps between door packing Loosen door panle screws and correct
Gaps between door and cabinet. and cabinet. distortion of door.
Frosting on evaporator. Check for excessive frosting on Defrost before frost grows more than
evaporator. ( This will deteriorate 10mm thick.
refrigerating efficiency ).
Fautt panel pcb. Check conduction of panel pcb. Replace the panel pcb.
- 12 -
9.EXPLODED VIEW AND PARTS LIST
9-1.DOOR PARTS
4 1 2
7
8
- 13 -
9-1-1. PARTS LIST
REF PART
NO NUMBER DESCRIPTION Q'ty SPEC REMARK
1 DA64-00368B HANDLE 1 WINE CH/GE,NCFC-ABS,-,-,-,-,
2 DA63-01257B GASKET DOOR 1 JC-125,SOFT-PVC,-,482.6
3 DA97-00418A ASSY-LOCK 1 JC-125,ZNDC2,1CR18NI9TI,-
4 DA64-00400B KEY-ASSY 1 SMR04,-,-,-,-,-,GE
5 DA64-00502E CHASSIS-SIDE,LEFT 1 NCFC-ABS RW13EBBB
DA64-00502D CHASSIS-SIDE,LEFT 1 NCFC-ABS RW13EBSS
6 DA64-00503B CHASSIS-SIDE,RIGHT 1 WINE CH/GE,NCFC- RW13EBBB
DA64-00503D CHASSIS-SIDE,RIGHT 1 NCFC-AB RW13EBSS
7 DA67-00605B CAP DOOR 1 WINE CH/GE,NCFC-ABS,-,-,-,
8 DA71-40133A STOPPER-DOOR,C 1 SCP1,T2.0,ZPC3(W)
- 14 -
9-2.REF PARTS
4
5 3
6
7
8
9
10
11
13
14 12
15
16
17
18
19
20
21
22
- 15 -
9-2-1. PARTS LIST
REF PART
NO NUMBER DESCRIPTION Q'ty SPEC REMARK
1 DA64-00506B TOP TABLE 1 RW13EBBB,ABS,BLACK,SAMSUN
2 6002-001106 SCREW-TAPPING 2 TH,+,SJ2823-87,M3.5,L
3 DA62-00134A INS ASSY-TOP##TABLE 1 JC-125,EPS,T23,
4 DA64-00508C INLAY-TOP TABLE 1 RW13EBBB,PC,T0.45,W
5 DA60-10130B SCREW-TAP,TH 2 1-4.2X13,FE,FZY(1018)
6 DA41-00124D PCB-PANEL 1 RW13EBBB,230/50,-,-,-,-,-
7 DA64-00518A BUTTON-L 1 JC-125,ABS,-,-,-,-
8 DA64-00507A BUTTON 1 JC-125,ABS,-,-,-,-
9 DA60-10124A SCREW-TAP TITE 8 ZPC2-Y 6X16 SR-53EA
10 DA61-00447A HINGE-UPP 1 JC-125,SCP1,-,-,-,-,-,-
11 DA61-00445A REINF-TOP TABLE 1 JC-125,SCP1,-,-,-,-
12 DA61-00456A GUIDE-TOP##TABLE 1 JC-125,ABS,T1.5,-,
13 DA63-01045B COVER-LAMP 1 WINE-CH/GE,PC,-,-,-,-,GE
14 DA60-10130G SCREW-TAPPING 2 TH 1-M4.2*9.5 ZN 35#
15 DA61-00650A FIXER-SCREW,TAPING 4 JC-125,ST3.5,L13
16 DA47-00091A LAMP HOLDER-CLAMP 2 -,-,-,-,PBT,UNFLA
17 DA47-00100B LAMP-FLUORESCENT 1 6400K,HAITUO,JC-12
18 DA32-00002E SENSOR 1 -,WINE CH,-,-,-,-,502AT ADD
19 DA63-01030A COVER EVAP 1 JC-125,HIPS,T2,W73,L176,
20 DA67-00481B SHELF WIRE-UPP 5 JC-125,Q1008(Q195),O
21 DA67-00480B SHELF WIRE-LOW 1 JC-125,Q1008(Q195),O
22 DA96-00019A ASSY EVAP SUCT 1 WINE CH/GE,AL-PLATE,
- 16 -
9-3.ASS'Y CABINET PARTS
5 6 7 8 11 9 10 12 13
2
3
21 14
4
20 18
16 19 15
17
- 17 -
9-3-1. PARTS LIST
REF PART
NO NUMBER DESCRIPTION Q'ty SPEC REMARK
1 DA70-00156B CABI FRAME 1 PCM,-,SRG-148,-,-,DANBY&
2 DA61-00912A FOOT 2 WINE CH/GE,NBR,-,-,-,-,-
3 DA61-00023C HINGE-LOW 1 SRG-148,SCP1,T3.5,-,-,SPR
4 DA60-10130G SCREW-TAPPING 3 TH 1-M4.2*9.5 ZN 35#
5 DA65-20113A CLAMP-RELAY COVER 1 SK-5
6 DA63-10722A COVER-RELAY 1 P.P V451
7 DA34-10003Q PROTECTOR-O/L 1 4TM166SFBYY-53
8 DA35-10013D PTC-RELAY 1 J531Q35E470M355-2
9 D130QL1Z/SJ2 COMPRESSOR 1 3.04cc,RSIR,220/240
10 DA60-20008A BOLT-HEX,COMP 4 SM30C L42.6
11 DA63-40234C GROMMET-COMP 4 NBR H27.8
12 DA73-30104G DRYER 1 CU OD18.85 L100 2P
13 DA66-00134A TRAY DRAIN-WATER 1 WINE CH,PP,-,-,-,N
14 DA71-00126B CHASSIS-COMP 1 SBHG1,TAX4,GE ROUND CO
15 DA39-00223B HARNESS RELAY-WIRE 1 RW13EBBB,-,UL101
16 DA61-00446B CASE JUNCTION 1 WINE CH/GE,PP(5VA),-,
17 DA39-10155B POWER-CORD 1 250V13A BS6500 BSI BS136
18 DA41-00123D PCB MAIN 1 RW13EBBB,230/50,-,-,-,-,-,
19 6501-000123 CABLE-TIE 1 DACT-150,W4*L150,NYLON,NT
20 6002-001113 SCREW-TAP,TH 3 2*7
21 DA26-00011D TRANS POWER-FORM 1 TIONG,JS-0500,-,-,
- 18 -
10. MICOM-PROGRAM-CHECK LIST
- 19 -
3. TEMPERATURE ADJUSTMEN
3-1 Press the "Custom" key for 3 seconds,the digital tube will display the user setting temperature
during the 3 seconds.Then,release the "Custom" key,the digital tube will display the user
setting temperature flickeringly.
3-2 During the 5 seconds flicker,press the "Red wine" key,the current temperature will increase
1C for each pressing action until the digital tube display 18C.
3-3 During the 5 seconds flicker,press the "White wine" key,the current temperature will decrease
1C for each pressing action until the digital tube display 4C.
3-4 After releasing the "Red wine" key and the "White wine" key,the digital tube will display the
actual temperature after 5 seconds .
3-5 The digital tube will display the temperature of the last setting when reentering the
temperature setting status.
5. RESET FUNCTION
5-1 The digital tube will fail to display if pressing both the "White wine" key and the "Red wine"
key at the same time.The "Red wine" light, the "White wine" light,the "Interior light" all should
be off and the compressor also should be off.
5-2 After 3 seconds,the digital tube will display the actual temperature and the "Red wine" light
will be on(the appliance recovers to the primary state).
6. ILLUMINATING FUNCTION
6-1 When pressing the "Interior light" key,the "Interior light" will be on or off when its' primary
status is off or on.
6-2 After 1 hour"s work,the "Interior light" will automatically go off if no action on the "Interior
light" key .
- 20 -
7. MAINTENANCE MODE
7-1 If holding down the "White wine" key, "Red wine" key and the "Interior light" key
simultaneously for 5 seconds,the digital tube will display"SE" for 1 second.The "White wine"
light, "Red wine" light and the "Custom" light will be on,the interior light and the compressor
will be off.
7-2 After "SE" appearing on the digital tube, release the"White wine" key,the "Red wine" key and
the "Interior light" key.If the actual temperature appearing on the digital tube is below 0C,the
digital tube will display 32C flickeringly until the actual temperature return into the
temperature range.
7-3 When pressing the "Custom" key,the compressor can be controlled to be on or off. The digital
tube will display “ON” or “OF” for 3 seconds after pressing the "Custom" key.
7-4 Under the maintenance mode,the compressor will restart at once.