www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.

0
Company: PT. Whidia Bharaya Page: 1
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

Specifier's comments: Add. New Support Pole

1 Input data
Anchor type and diameter: HIT-RE 500 V3 + HAS-U 5.8 M16
Effective embedment depth: hef,act = 216 mm (hef,limit = - mm)
Material: 5.8
Evaluation Service Report: ESR-3814
Issued I Valid: 1/1/2020 | 1/1/2021
Proof: Design method ACI 318-14 / Chem
Stand-off installation: eb = 0 mm (no stand-off); t = 20 mm
Anchor plate: lx x ly x t = 200 mm x 200 mm x 20 mm; (Recommended plate thickness: not calculated
Profile: Flat bar, 100 x 10; (L x W x T) = 100 mm x 10 mm
Base material: cracked concrete, , fc' = 2,611 psi; h = 340 mm, Temp. short/long: 30/30 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.0
Company: PT. Whidia Bharaya Page: 2
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

2 Load case/Resulting anchor forces y


Load case: Design loads

Anchor reactions [kN] 3 4


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 11.225 3.025 0.008 -3.025
2 11.225 3.025 0.008 -3.025 x
3 11.225 3.025 0.008 -3.025 Tension
4 11.225 3.025 0.008 -3.025

max. concrete compressive strain: - [‰] 1 2


max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 44.901 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

3 Tension load
Load Nua [kN] Capacity f Nn [kN] Utilization bN = Nua/f Nn Status
Steel Strength* 11.225 51.025 22 OK
Bond Strength** 44.901 73.818 61 OK
Sustained Tension Load Bond Strength* N/A N/A N/A N/A
Concrete Breakout Strength** 44.901 54.953 82 OK
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


Nsa = ESR value refer to ICC-ES ESR-3814
f Nsa ≥ Nua ACI 318-14 Table 17.3.1.1

Variables
Ase,N [mm2] futa [N/mm2]
157 500.00
Calculations
Nsa [kN]
78.500
Results
Nsa [kN] f steel f Nsa [kN] Nua [kN]
78.500 0.650 51.025 11.225

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.0
Company: PT. Whidia Bharaya Page: 3
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

3.2 Bond Strength

Nag = (AA ) y
Na
Na0
ec1,Na y ec2,Na y ed,Na y cp,Na Nba ACI 318-14 Eq. (17.4.5.1.b)
f Nag ≥ Nua ACI 318-14 Table 17.3.1.1
ANa = see ACI 318-14, Section 17.4.5.1, Fig. R 17.4.5.1(b)
ANa0 = (2 cNa)2 ACI 318-14 Eq. (17.4.5.1c)
cNa = 10 da √ t uncr
1100
ACI 318-14 Eq. (17.4.5.1d)

( )
1
y ec,Na = e' ≤ 1.0 ACI 318-14 Eq. (17.4.5.3)
1+ N
cNa
y ed,Na = 0.7 + 0.3 ( ) ca,min
cNa
≤ 1.0 ACI 318-14 Eq. (17.4.5.4b)

y cp,Na = MAX ( )
ca,min cNa
,
cac cac
≤ 1.0 ACI 318-14 Eq. (17.4.5.5b)
Nba = l a · t k,c · p · da · hef ACI 318-14 Eq. (17.4.5.2)

Variables
2 2
t k,c,uncr [N/mm ] da [mm] hef [mm] ca,min [mm] aoverhead t k,c [N/mm ]
15.37 16 216 160 1.000 8.76
ec1,N [mm] ec2,N [mm] cac [mm] la
0 0 515 1.000
Calculations
cNa [mm] ANa [mm2] ANa0 [mm2] y ed,Na
227 269,357 205,592 0.912
y ec1,Na y ec2,Na y cp,Na Nba [kN]
1.000 1.000 1.000 95.075
Results
Nag [kN] f bond f Nag [kN] Nua [kN]
113.566 0.650 73.818 44.901

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.0
Company: PT. Whidia Bharaya Page: 4
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

3.3 Concrete Breakout Strength

Ncbg = (AA ) y
Nc
Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-14 Eq. (17.4.2.1b)
f Ncbg ≥ Nua ACI 318-14 Table 17.3.1.1
ANc see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b)
ANc0 = 9 h2ef ACI 318-14 Eq. (17.4.2.1c)

( )
1
y ec,N = 2 e'N ≤ 1.0 ACI 318-14 Eq. (17.4.2.4)
1+
3 hef
y ed,N = 0.7 + 0.3 (
ca,min
1.5hef )
≤ 1.0 ACI 318-14 Eq. (17.4.2.5b)

y cp,N = MAX (
ca,min 1.5hef
cac
,
cac )
≤ 1.0 ACI 318-14 Eq. (17.4.2.7b)
1.5
Nb = kc l a √fc hef
'
ACI 318-14 Eq. (17.4.2.2a)

Variables
hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm] y c,N
216 0 0 160 1.000

cac [mm] kc la f'c [psi]


515 17 1.000 2,611

Calculations
ANc [mm2] ANc0 [mm2] y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
436,832 419,904 1.000 1.000 0.848 1.000 95.817
Results
Ncbg [kN] f concrete f Ncbg [kN] Nua [kN]
84.543 0.650 54.953 44.901

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.0
Company: PT. Whidia Bharaya Page: 5
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

4 Shear load
Load Vua [kN] Capacity f Vn [kN] Utilization bV = Vua/f Vn Status
Steel Strength* 3.025 28.200 11 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Concrete Breakout 12.098 118.360 11 OK
Strength controls)**
Concrete edge failure in direction y-** 12.098 25.594 48 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength


Vsa = ESR value refer to ICC-ES ESR-3814
f Vsteel ≥ Vua ACI 318-14 Table 17.3.1.1

Variables
Ase,V [mm2] futa [N/mm2]
157 500.00
Calculations
Vsa [kN]
47.000
Results
Vsa [kN] f steel f Vsa [kN] Vua [kN]
47.000 0.600 28.200 3.025

4.2 Pryout Strength (Concrete Breakout Strength controls)

Vcpg = kcp [(AA ) y


Nc
Nc0
ec,N ]
y ed,N y c,N y cp,N Nb ACI 318-14 Eq. (17.5.3.1b)
f Vcpg ≥ Vua ACI 318-14 Table 17.3.1.1
ANc see ACI 318-14, Section 17.4.2.1, Fig. R 17.4.2.1(b)
ANc0 = 9 h2ef ACI 318-14 Eq. (17.4.2.1c)

( )
1
y ec,N = 2 e'N ≤ 1.0 ACI 318-14 Eq. (17.4.2.4)
1+
3 hef
y ed,N = 0.7 + 0.3 (
ca,min
1.5hef )
≤ 1.0 ACI 318-14 Eq. (17.4.2.5b)

y cp,N = MAX (
ca,min 1.5hef
cac
,
cac )
≤ 1.0 ACI 318-14 Eq. (17.4.2.7b)
1.5
Nb = kc l a √fc hef
'
ACI 318-14 Eq. (17.4.2.2a)

Variables
kcp hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm]
2 216 0 0 160

y c,N cac [mm] kc la f'c [psi]


1.000 515 17 1.000 2,611

Calculations
ANc [mm2] ANc0 [mm2] y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
436,832 419,904 1.000 1.000 0.848 1.000 95.817
Results
Vcpg [kN] f concrete f Vcpg [kN] Vua [kN]
169.086 0.700 118.360 12.098

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.0
Company: PT. Whidia Bharaya Page: 6
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

4.3 Concrete edge failure in direction y-

Vcbg = (AA ) y
Vc
Vc0
ec,V y ed,V y c,V y h,V y parallel,V Vb ACI 318-14 Eq. (17.5.2.1b)
f Vcbg ≥ Vua ACI 318-14 Table 17.3.1.1
AVc see ACI 318-14, Section 17.5.2.1, Fig. R 17.5.2.1(b)
AVc0 = 4.5 c2a1 ACI 318-14 Eq. (17.5.2.1c)

( )
1
y ec,V = 2e'v ≤ 1.0 ACI 318-14 Eq. (17.5.2.5)
1+
3ca1
y ed,V = 0.7 + 0.3 (ca2
1.5ca1 )
≤ 1.0 ACI 318-14 Eq. (17.5.2.6b)

y h,V = √
1.5ca1
ha
≥ 1.0 ACI 318-14 Eq. (17.5.2.8)

(( ) )
0.2
l 1.5
Vb = 7 e √da l a √f'c ca1 ACI 318-14 Eq. (17.5.2.2a)
da

Variables
ca1 [mm] ca2 [mm] ecV [mm] y c,V ha [mm]
160 350 0 1.000 340

le [mm] la da [mm] f'c [psi] y parallel,V


128 1.000 16 2,611 1.000

Calculations
AVc [mm2] AVc0 [mm2] y ec,V y ed,V y h,V Vb [kN]
139,200 115,200 1.000 1.000 1.000 30.259
Results
Vcbg [kN] f concrete f Vcbg [kN] Vua [kN]
36.563 0.700 25.594 12.098

5 Combined tension and shear loads


bN bV z Utilization bN,V [%] Status
0.817 0.473 5/3 101 not recommended
bNV = bzN + bzV <= 1

6 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid anchor plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Condition A applies when supplementary reinforcement is used. The Φ factor is increased for non-steel Design Strengths except Pullout
Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout
Strength. Refer to your local standard.
• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions
• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant
standard!
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-14,
Section 17.8.1.

Fastening does not meet the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.0
Company: PT. Whidia Bharaya Page: 7
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

7 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-RE 500 V3 + HAS-U 5.8 M16
Profile: Flat bar, 100 x 10; (L x W x T) = 100 mm x 10 mm Installation torque: 0.080 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 20 mm Hole depth in the base material: 216 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 252 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to
instructions for use is required

7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Torque wrench
the hole
• Proper diameter wire brush
y

100 100

50

100
3 4
100

x
100

1 2
50

50 100 50

Coordinates Anchor mm
Anchor x y c-x c+x c-y c+y
1 -50 -50 - 450 160 -
2 50 -50 - 350 160 -
3 -50 50 - 450 260 -
4 50 50 - 350 260 -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.id/content/hilti/A2/ID/en/engineering/software/anchor-design-software.html Profis Anchor 2.9.0
Company: PT. Whidia Bharaya Page: 8
Specifier: Engineer Project: Colo HCPT rev.6
Address: JL. Katalia I no. 20, Palmerah, Jak-Bar Sub-Project I Pos. No.: Rumah Makan Mutiara
Phone I Fax: 021-565 5775 | 021-565 5775 Date: 25/06/2024
E-Mail: admin@whidia-bharaya.co.id

8 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like