Professional Documents
Culture Documents
BRC Price List Jun 21
BRC Price List Jun 21
Ductility Class A
Std Sheet
Main Wire Cross Wire Area Mass Price
Mesh (6.0mx2.4m)
Reference Dia Spacing Dia Spacing
Main
Cross
(mm2/ (kg/m2) (S$/m2) (S$/pc)
(mm) (mm) (mm) (mm) (mm2/m)
m)
Square Mesh
“A” Series
WA13 13 200 13 200 664 664 10.42 19.60 282.24
WA12 12 200 12 200 566 566 8.88 17.40 250.56
WA10 10 200 10 200 393 393 6.16 11.58 166.75
WA9 9 200 9 200 318 318 4.99 9.78 140.83
WA8 8 200 8 200 251 251 3.95 7.43 106.99
WA7 7 200 7 200 193 193 3.02 6.19 89.14
WA6 6 200 6 200 142 142 2.22 4.55 65.52
“D” Series
WD13 13 100 13 100 1328 1328 20.84 39.16 563.90
WD12 12 100 12 100 1131 1131 17.76 34.81 501.26
WD10 10 100 10 100 786 786 12.32 23.16 333.50
WD9 9 100 9 100 636 636 9.98 19.56 281.66
WD8 8 100 8 100 503 503 7.90 14.85 213.84
WD7 7 100 7 100 385 385 6.04 12.39 178.42
WD6 6 100 6 100 283 283 4.44 9.11 131.18
“E” Series
WE13 13 150 13 150 885 885 13.89 26.11 375.98
WE12 12 150 12 150 754 754 11.84 23.21 334.22
WE10 10 150 10 150 524 524 8.23 15.47 222.77
WE9 9 150 9 150 424 424 6.67 13.07 188.21
WE8 8 150 8 150 335 335 5.27 9.91 142.70
Rectangular Mesh
“B” Series
WB13 13 100 10 200 1328 393 13.50 25.38 365.47
WB12 12 100 8 200 1131 251 10.90 21.36 307.58
WB10 10 100 8 200 786 251 8.17 15.36 221.18
WB9 9 100 8 200 636 251 6.97 13.66 196.70
WB8 8 100 8 200 503 251 5.93 11.15 160.56
WB7 7 100 7 200 385 193 4.53 9.29 133.78
WB6 6 100 7 200 283 193 3.73 7.65 110.16
Notes:
a. Diameter 6mm and 7mm mesh for non-structural use only according to SS561:2010.
b. Standard sheet size shall be 6.0m x 2.4m with a minimum of 100mm main and cross wire overhang.
1
Standard Mesh
Ductility Class B
Square Mesh
"A" Series
HA16 16 200 16 200 1006 1006 15.79 37.12
HA13 13 200 13 200 664 664 10.42 23.45
HA10 10 200 10 200 393 393 6.16 13.86
HA8 8 200 8 200 251 251 3.95 8.89
"D" Series
HD16 16 100 16 100 2012 2012 31.59 74.23
HD13 13 100 13 100 1328 1328 20.83 46.87
HD10 10 100 10 100 786 786 12.32 27.72
HD8 8 100 8 100 503 503 7.90 17.77
"E" Series
HE16 16 150 16 150 1341 1341 21.05 49.48
HE13 13 150 13 150 885 885 13.89 31.26
HE10 10 150 10 150 524 524 8.23 18.52
HE8 8 150 8 150 335 335 5.27 11.86
Rectangular Mesh
"B" Series
HB16 16 100 13 200 2012 664 21.01 49.37
HB13 13 100 10 200 1328 393 13.50 30.38
HB10 10 100 8 200 786 251 8.17 18.38
HB8 8 100 8 200 503 251 5.93 13.34
2
Engineered Mesh
Single Directional F-mesh – Ductility Class A
3
Engineered Mesh
Single Directional F-Mesh – Ductility Class B
Mesh Main Wire Area Holding Wire Mass Price
Dia Spacing Main Dia Spacing
Reference (mm) (mm) (mm2/m) (mm) (mm)
(kg/m2) (S$/m2)
4
Engineered Mesh
Customized to Specification – Ductility Class A & B
Customized mesh can be manufactured by combining different main and cross wire configurations to suit the
specific design requirements for your project.
Notes:
a. Nomenclature for customized Engineered Mesh as follows:
[W for Class A / WH for Class B] [Main Wire Dia XX][Spacing XX] [Cross Wire Dia XX][Spacing XX]
For example:
Ductility Main Wire Cross Wire Price
Specification Size Spacing Size Spacing
Class (mm) (mm) (mm) (mm)
(S$/m2)
Beam Cage Dimension Column Cage Dimension Beam / Column Capping Dimension
Overall Stirrup Dimension (OSD) = Overall Stirrup Dimension (OSD) = Overall Stirrup Dimension (OSD) =
Area = OSD x length of holding wire Area = OSD x length of holding wire Area = OSD x length of holding wire
Weight = Area x Mass (kg/m2) Weight = Area x Mass (kg/m2) Weight = Area x Mass (kg/m2)
Notes:
6
Core Cage for HDB Precast Elements
Notes:
7
Core Cages for HDB Precast Elements
Notes:
a. Nomenclature for core cage as follows:
[CA] [Core width] x [Core depth] - [No. of Main Bars] [Diameter of Main Bars] [A]
b. Core cage shall follow HDB / consultant's specifications, subject to detailing by manufacturer as final.
c. Termination bar where applicable shall be supplied separately based on cut and bend rate.
8
Standards
BRC Asia Limited supplies steel welded fabric / wires / bars to the following standards:
1. SS18: Part 1: 1999 – Cold-reduced steel wire for the reinforcement of concrete and the manufacture of
welded fabric – Steel grade 500.
2. SS32: Part 1: 1999 – Welded steel fabric for the reinforcement of concrete.
3. SS560:2016 – Steel for the reinforcement of concrete – Weldable reinforcing steel – Bar, coil and decoiled
product. Steel grade B500A for the wires 13mm and below, steel grade B500B for bars 16mm, 20mm, 25mm,
28mm, 32mm, 40mm.
4. SS561:2010 – Steel fabric for the reinforcement of concrete (B500A and B500B).
Disclaimers
While great care has been taken to ensure the accuracy of all prices and product information, BRC Asia Limited
reserves the right to correct errors and adjust prices to account for circumstances beyond our control.
Where there is a discrepancy between the prices of a standard mesh / F-mesh panel and an identical customized
engineered mesh, the standard mesh / F-mesh price will be applied.
All unit weight and prices presented in this price list are calculated and rounded to the nearest value. Where
there is a discrepancy between weight and / or prices listed in this price list and our delivery orders and invoices,
values stated in our delivery orders and invoices will be deemed as final.