CAMP MASTER STORE
BUILT UP

PANDA P-003

20% OF TOTAL WORK

www.axaguide.com
Summary

Work Execution Time Cost in ( )


Work Included
(%) (Days) (Approx.)
ELECTRICAL WORK 50% 15 Days 00.00

All Electrical Wiring Work

All Cabling Work

Fire Extinguisher

AIR CONDITIONER WORK 30% 6-7 Days 00.00

Air Conditioner Pipe/ Ducting, Cables,


and Drain Piping Work

www.axaguide.com
Work Statement
Particulars Page No.
A Electrical Work
Distribution Boards 6

Cables and Wires 7

Point Wiring Work

Light Point 8

Plug Point 9

Power Point 10

AC Point 11

Fan Point 12

Invertor Wiring 13

Music System Point 14

Exhaust Fan Point 15

Telephone Point and Wiring 16-17

Data Cabling System 18-20

Earthing Work 21-22

Web Cam In Conference 23-24

Access Control System 25-26

CCTV Camera System 27-28

Fire Fighting System 29-30

Www.Axaguide.Com
Work Statement
Particulars Page No.

B Air Conditioner work


4.0 Tr Cassette Air Conditioner 31

1 TR & 1.5 TR Slit Air Conditioner 32

Other Air Conditioner ancillary work

Cu Piping work 33

Cabling 34

Drain piping 35

www.axaguide.com
A Electrical work
DISTRIBUTION BOARD
Work Execution Time Quantity Cost in ( )
Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

BACK OFFICE 90% 2 Days 3 No. 00.00

1
• Supply, installing, testing and commissioning of metallic double door type distribution board with all
necessary connection complete to be installed concealed in wall / surface mount complete to the
satisfaction of the Engineer in charge. The DB should be of same make as MCB make. All MCBs & ELCBs
must be 10KA Short Circuit Current Rated. All DBs Must be Legrand Model EKINIOX3 or Hager Model
NOVELLO+ or L&T Model EXORA or C&S Model Wintrip.
• 16 WAY SPN DB incoming : 40A FP MCB . incoming : 25A DP MCB -.From UPS Room incoming : 32A DP
MCB outgoing : 10A SP MCB -FOR Lighting outgoing : 25A DP -FOR AC outgoing : 25A DP ELCB,100mA -
FOR UPS O/P All MCBs must be C-type
Note- Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

6 www.axaguide.com
CABLES AND WIRES

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

OFFICE WIRING 4 SQMM 100% 6 Days 200 M.tr. 00.00


OFFICE WIRING 2.5 SQMM 100% 6 Days 550 M.tr. 00.00
OFFICE WIRING 1.5 SQMM 100% 6 Days 850 M.tr. 00.00
OFFICE WIRING 1.0 SQMM 100% 6 Days 90 M.tr. 00.00

Wire Brands- Polycab, Finolex

2
• Supply, Lying, installation, testing and commissioning of following sizes of PVC insulated PVC sheathed
copper cable to be laying in existing cable trench or to be laid in pipes of with necessary clamps,
spacers with cleating on wall ceiling etc.
• 4 sq mm X 2 + 2.5 X 1 wire for A.C./ power Main with PVC Pipe
• 2.5sq mm x 2 + 1.5sqx 1 cu flex wire with PVC Pipe 1.5sq mm x 2 + 1.0sq x 1 cu flex wire(Circuit Wiring
from SB)with PVC Pipe
• 1 sq mm x 2 + 1.0sq x 1 cu flex wire(Circuit from SB)with PVC Pipe

7 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 60% 5-6 Days 200 No. 00.00

Switches Series- Legrand Myrius

3.1
• Light point- Concealed conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm +
1(1x1sqmm ) PVC single core copper wire in PVC/ Super polythene pipe with galvanized iron junction
& switch boxes & clip in type 6 Amp modular type switches with all accessories

Note- Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

8 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE DESKS 60% 5-6 Days 120 No. 00.00

Switches Series- Legrand Myrius

3.2
• Plug point - Concealed conduit wiring to 6/16 Amp plug socket with switch on separate board with
(2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper wire in PVC/ Super polythene pipe with
galvanized iron junction & switch boxes & clip in type 6 Amp modular type switches with all
accessories

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage

9 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 60% 5-6 Days 15 No. 00.00

Switches Series- Legrand Myrius

3.3
• Power Points - Concealed conduit wiring to 20 Amp plug socket with switch on separate board with
(2x2.5 sq mm + 1(1x1.5 sqmm ) PVC single core copper wire in PVC/ Super polythene pipe with
galvanized iron junction & switch boxes & clip in type 15 Amp modular type switches with all
accessories

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

10 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 60% 4-5 Days 15 No. 00.00

Switches Series- Legrand Myrius

3.4
• A/C Points - Supply of all required materials and wiring to AC plug point with 2 (1x4sqmm) PVC
insulated copper wire run inside screw type PVC conduit pipe with ISI market laid on
surfaced/recessed of wall/celling alongwith 1 (1x2.5sqmm) PVC insulated copper wire as earth
continuity conductor complete in all respect including with use of 1.5 TR AC starter, concealed metal
boxes with cover, wire, 20A SPN metalclad plug socket, metalic switch box for plug, junction box etc
complete

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

11 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 60% 2-3 Days 7 No 00.00

Switches Series- Legrand Myrius

3.5
• Fan point with regulator - Concealed conduit wiring to fan, exhaust fan points with (2x1.5 sq mm +
1(1x1sqmm ) PVC single core copper wire in PVC/ Super polythene pipe with galvanized iron junction
& switch boxes & clip in type 6 Amp modular type switches and regulator with all accessories

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

12 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

BACK OFFICE 100% 5-6 Days 1 No. 00.00

3.6
• Invertor Wiring - Concealed conduit wiring invertor points with (2x1.5 sq mm + 1(1x1sqmm ) PVC
single core copper wire in PVC/ Super polythene pipe with galvanized iron junction & switch boxes &
clip in type 6 Amp modular type switches with all accessories

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

13 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 50% 2-3 Days 1 System 00.00

3.7
• Music system point wiring - Supply & Fixing of Philips Make 6" dia Ceiling Mounted Speaker 10 nos.

• Supply & Fixing of 0.75 Twin Flexible wire with Pvc Pipe

• Supply & Fixing of Volume Controller 1Nos

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage

14 www.axaguide.com
POINT WIRING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 50% 2-3 Days 9 System 00.00

3.8
• Exhaust Fan Point–Ceiling Mounted Exhaust Fan Point (Havells Ventilair DXC 130 mm Roof
Mounting Exhaust Fan White) with Ducting work.

• Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage

15 www.axaguide.com
TELEPHONE POINT AND WIRING

Area of Application Work Execution Time Quantity Cost in ( )

Front & Back Office


(%) (Days) (Sq. Ft.) (Approx.)

SYNTEL 3*12 NEO DX 312 0% 0 Days 1 No. 00.00


CABLE 100% 5-6 Days 250 M.tr. 00.00
20 PAIR MDF BLOCK 0% 0 Days 1 No. 00.00
MODULAR RJ 11 VOICE OUTLET 0% 0 Days 12 No 00.00

Cable Brand- Polycab

DATA FOR VOICE

• Syntel 3*12 NEO DX 312 -Configure for 12 lines EXT with 3 co as Trunk line complete with all respects
complying with relevant standard specification

16 www.axaguide.com
• Supplying, Laying, termination, testing and commissioning in the conduit /PVC Raceway on wall /Cable
manager in modular furniture Duct etc. including Labelling for the identification of Category 2 pair
Pvc Make-Polycab, slate jacket, 2 pair count, , as complete with all respects complying with relevant
standard specification as mentioned in the Technical Specification, as directed.(Cable for VOICE) -
make – Polycab

• Supply and Installation for following Tag block in M.S. Enclosure of 2 mm thick, ,200x150x100mm in
Size & duly powered coated & with pair of Krone type connector including required glanding
termination with special krone tool.

• 20 Pair MDF Block fully loaded

• Supply and fixing of Modular RJ 11 voice outlet duly with concealed box face plate etc. including
required termination

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

17 www.axaguide.com
DATA CABLING SYSTEM

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE DESKS 60% 6-7 Days 1 System 00.00

Cable Brand- Polycab

5
CAT6A DATA PORTS

• CAT6A UTP Patch Cord, 1M Make - Digisol / D-Link

• CAT6A UTP Patch Cord, 2M Make - Digisol / D-Link

• Network Switch 24-Port Gigabit Unmanaged Switch

DGS-1024C D-LINK

18 www.axaguide.com
Economical, plug-and-play networking switch for SOHOs and small and medium businesses.

24 Gigabit LAN ports for high-speed wired connections

Plug-and-play installation for convenience

Auto-negotation on all ports

Half/full-duplex, auto MDI/MDIX, and store-and-forward switching

Full wire-speed data transmission

Energy-efficient design

• 96 Port Straight Patch Panel, loaded Make - Digisol / D-Link - Supplying, Laying, termination, testing
and commissioning and punching/Cable manager including Labelling for the identification of Category
UTP above material as complete with all respects complying with relevant standard specification as
mentioned in the Technical Specification.

• DIGISOL Solid Cable, Cat6 SFTP, 4 Pair, 23AWG, FRPVC CM, Grey, Nodal - DGC-SC6SF4F-3GB Or
Equivalent D-Link

Mechanical Properties:

Conductor : 23AWG Solid Bare Cable

Central Element : PE Cross Separator

Insulation : High Density Polyethylene Solid

Pairs : 4 Pairs Twisted Together

Shielding : Aluminum/Polyester Foil

Overall Sheath : Tinned Copper Braiding

Cable Diameter : 6.80 mm Nominal

Rip cord : Yes

Jacket : FRPVC/LSZH sheath

Jacket Color : Light Grey

Bending Radius : < 8X Cable Diameter at -20°C +/- 1°C

Pulling Force : 25.35 LBS

19 www.axaguide.com
Operating Temperature : (-20°C to +70°C) - Supplying, Laying, termination, testing and commissioning in
the conduit /PVC Raceway on wall/Cable manager in modular furniture Duct etc. including Labelling for
the identification of Category UTP above material as complete with all respects complying with relevant
standard specification as mentioned in the Technical Specification.

• D-Link / Digisol I/o for RJ45 punching - Supplying, fixing, termination, testing and commissioning and
punching/Cable manager including Labelling for the identification of Category UTP above material as
complete with all respects complying with relevant standard specification as mentioned in the
Technical Specification.

• D-Link / Digisol Faceplate - Supplying, fixing, termination, testing and commissioning and including
Labelling for the identification of Category UTP above material as complete with all respects complying
with relevant standard specification as mentioned in the Technical Specification

• D-Link Wall Mount Rack NWR-12U-500mm

Specifications- Rack Standard : Conforms to DIN 41494 or equivalent standard Construction : Welded
Front Door : Lockable Toughened Glass Door Basic Frame : Steel Equipment Mounting : DIN Standard Slots
Mounting Angle : 19” Mounting angles made of formed steel Standard Finish : Powder Coated Top and
Bottom Cover : Welded to Frame, Vented and Field Cable entry exit cut outs Standard Color : Grey Static
Load : 50 kgs.

• Labels for faceplate, patch panels, self laminated or PVC labels for cords, total quantity required for
completion of the entire project – As required

• Velcro Tie wraps, total quantity required for entire project - As required

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

20 www.axaguide.com
EARTHING WORK

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

IF REQUIRED 0% 0 Days 00 Sq. Ft. 00,000.00

6
• Supply, Installation, Testing and Commissioning of Maintenance Free Earthing system made up of
copper-bonded rod of 10 feet length,23 mm dia. (Minimum copper bonding shall be 0.25mm) along
with Rod-to-Conductor connectors, Earth enhancement material, Pit Cover and other accessories as
required and as per specification and other applicable codes (include chamber for earthing, Earthing
certificate to be submitted along with the bill

• Supply, Installation, Testing and Commissioning of Maintenance Free Earthing system made up of
copper-bonded rod of 10 feet length, 17.2 mm dia. (Minimum copper bonding shall be 0.25 mm) along
with Rod-to-Conductor connectors, Earth enhancement material, Pit Cover and other accessories as
required and as per specification and other applicable codes (include chamber for earthing, Earthing
certificate to be submitted along with the bill).

21 www.axaguide.com
• Providing and fixing of Copper/ GI strips in surface or in recess for loop earthing etc. as required.

• 25 mm x 3 mm copper strip in B-class GI pipe RM 5.00

• 25 mm x 3 mm copper strip with proper clamps RM 10.00

• 25 mm x 5 mm GI strip RM 20.00 iv Providing and fixing 2 X 8 SWG dia. Cu earth wire in PVC conduit on
surface or in recess for loop earthing along with

22 www.axaguide.com
WEB CAM, SOUND AND MIC FOR CONFERENCE

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

CONFERENCE 60% 3-4 Days 3 No 00.00

• Logitech Conference Cam BCC950 Video Conference Webcam HD 1080p Camera with Built-In
Speakerphone

• VIDEO CONFERENCING FOR UP TO 4 PEOPLE WITH HD QUALITY Small groups can run their own video
conferences anytime, anywhere. BCC950 video conferencing system, with its high-definition, plug-and-
play webcam and speakerphone, is ideal for small rooms or small groups. Set it up quickly and easily at
an office desk or on a conference table. HD video and crystal-clear audio combine high quality with
affordability.

23 www.axaguide.com
• ALL-IN-ONE DESIGN Just plug and play. BCC950 includes wideband audio from a full duplex
speakerphone and HD video. In other words, it’s everything you need to quickly launch a small video
conference with up to 4 people in one room.

• EASY TO SET UP AND USE Compatible with both PC and Mac and designed to work with many video
conferencing software applications, BCC950 makes it easy to launch a small group video collaboration
at a moment’s notice. No training required.

• PERFECT FOR PRODUCTIVE TEAMS BCC950 is designed with small groups in mind. Omni-directional
speaker and noise-cancelling microphone allow all meeting members to clearly hear and be heard up
to 8 feet away. BCC950 is designed for use in private offices, home offices, or virtually any semi-private
space.

• WORKS WITH POPULAR MEETING APPS Use the video conferencing software you’re already familiar
with. BCC950 works with virtually any VC application, including Microsoft Lync, Skype, Skype for
Business, WebEx, and most other popular video conferencing platforms.

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

24 www.axaguide.com
ACCESS CONTROL & BIOMETRIC (ID & FINGERPRINT)

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

EVERY DOOR EXCEPT TOILET DOORS 60% 4-5 Days 3 System 00.00

8
• Supply Installation Testing & commissioning of ESSL k-90 Fingerprint Capacity 800
Card Capacity 800
Transaction Storage 80,000
Push Data Yes
Card Reader Yes
Fingerprint Sensor 500DPI Optical Sensor
Algorithm Ver 10
LED Indicator Green /Red
Schedule Bell/Speaker Mini Speaker
Communication TCP/IP, USB-Host

25 www.axaguide.com
• Standard Features Inbuilt Battery Backup, Self Service Query, SSR Recorder, Automatic Status Switch,
DST, T9 Input
Quantity= 2Nos
• Supply Installation Testing & commissioning of ESSL FINGERPRINT - X7 Category: Fingerprint Access
Control System
Features:
Card Capacity : 2000 ,
Fingerprint Capacity : 200 ,
Password Capacity : 8 groups,
Sensor : Optical Sensor.
Quantity= 11Nos
• EXIT PUSH BUTTON ESSL FOR exit for cabins Quantity= 11Nos
• Supply Installation Testing & commissioning of ESSL - EM LOCK 600LBS ELECTROMAGNETIC Lock
Voltage 12V DC (380mA)
Size : 250(L)x48(W)x27(H)mm Included with U _ L - Brackets
Quantity=11Nos
• Centralized Supply Installation Testing & commissioning of Licensed WEB BASED SOFTWARE with
demo and training of configuration_registration_shift assignment_report generation. Android app
configuration and settings training onetime for the marketting and techno commercials to marj their
attendance while on roaming @ real-time. ONE TIME INSTALLATION ONLY. EXPANSION OR
RECONFIGURATION WILL BE CHARGED AT ACTUAL IN FUTURE ENDEAVOUR. SUPPORT - ONLINE
THROUGH REMOTE DESKTOP. Quantity=1No
• DIGISOL Solid Cable, Cat6 SFTP, 4 Pair, 23AWG, FRPVC CM, Grey, Nodel - DGC-SC6SF4F-3GB Or
Equivalent D-Link - Mechanical Properties:-
Conductor : 23AWG Solid Bare Cable
Central Element : PE Cross Separator
Insulation : High Density Polyethylene Solid
Pairs : 4 Pairs Twisted Together
Shielding : Aluminium/Polyster Foil
Overall Sheath : Tinned Copper Braiding
Cable Diameter : 6.80 mm Nominal
Rip cord : Yes
Jacket : FRPVC/LSZH sheath
Jacket Colour : Light Grey
• Bending Radius : < 8X Cable Diameter at -20°C +/- 1°C
Pulling Force : 25.35 LBS
Operating Temperature : (-20°C to +70°C) - Supplying, Laying, termination, testing and commissioning
in the conduit /PVC Raceway on wall/Cable manager in modular furniture Duct etc including
Labelling for the identification of Category UTP above material as complete with all respects complying
with relevant standard specification as mentioned in the Technical Specification.
Quantity= 325 Mtr
Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

26 www.axaguide.com
CCTV CAMERA SYSTEM

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 50% 3 Days 3 System 00.00

9
CCTV SYSTEM 2MP - MAKE HIKVISION

• Supply Installation Testing & commissioning of 2MP IR DOME CAMERA , with fixed Lens, 3.6 mm lens,
H.265/MJPEG, dual -Stream, UP to 10m IR, DC12V/ Full HD, Smart IR, 20/30m IR, Support motion
detection, UL LISTED. CERTIFICATE CE & FCC...MODEL - DS-2CE5AD0T-IRF (METAL) Quantity=16No

• Premium power supply for 8 cameras ports including standard connectivity accessories. (for CCTV
Camera of 8nos each SEPARATE POWER SUPPLY) (MICROPOWER OR EQUIVALENT) Quantity=1No

27 www.axaguide.com
• Supply of 8 channel hd DVR support up to 2mp for CCTV system - MODEL - DS-7A08HQHI-K1
Quantity=1No

• Supply of 15.6" Enter / Zebion / Power X /Equivalent Monitor for CCTV system (OPTIONAL)
Quantity=1No

• Supply of Hard drive Purple 4TB WD or Seagate Surveillance for CCTV system for approx. 45days of
storage. Quantity=1No

• Premium Dlink or Equivalent CCTV 3+1 model cable with fitting supply conduit flexible testing above
POP or duct length around 200mts Quantity=400Mtr

• IVMS DESKTOP OR HIKCONNECT CONFIGURATION FOR MOBILE USER AND ONLINE REMOTE VIEWING
CONFIGURATION Quantity=4No

• Standard MX make BNC brass quality for video signal connection of camera of HD Hikvision make
Quantity=12No

• Standard MX make DC brass quality for video signal connection of camera of HD Hikvision make
Quantity=6No

Note - Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

28 www.axaguide.com
FIRE EXTINGUISHER

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 100% 3 Days 8 No 00.00

10
Eco Fire ABC Powder Type 2 Kg Fire Extinguisher (Red)

• ISI, BIS Mark, ISO and CE Certified Product and Multipurpose Uses ABC Type fire extinguisher 2 Kg

• ABC Types Fire extinguishers are effective for all types of fire like Class A, B and C types of fires as well
as Electrical fires and also ABC Powder Type (Stored Pressure) Fire Extinguisher, Multipurpose uses

29 www.axaguide.com
FIRE EXTINGUISHER

Work Execution Time Quantity Cost in ( )


Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

SERVER ROOM 100% 5 Days 2 No 00.00

10
• ECO FIRE Automatic Modular ABC Powder Type Fire Extinguisher (5 Kg)

• Clear Instruction Label & No Maintenance

• ISO & CE Certified Product

• Automatic Modular types Fire Extinguisher

• Applicable on Class A, B, C and electrically started Fire

30 www.axaguide.com
B Air Conditioner Work
4.0 TR CASSETTE AIR CONDITIONER UNIT
Work Execution Time Quantity Cost in ( )
Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

STAFF AREA 2 No 00.00

1
• Ceiling Mounted 4-way Cassette type AC with scroll / Rotary / Twin rotary / Reciprocating compressor,
having R 22 refrigerant. Including indoor unit outdoor unit. decorative grille and cordless remote
Machine shall have copper condenser Unit. The above specified units shall be supplied as per following
schedule installed at locations as mentioned in the layout
• 4.0 TR Daikin Cassette Air conditioner unit with cordless Remote control
Note- Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

31 www.axaguide.com
1.0 TR & 1.5 TR SPILT AIR CONDITIONER UNIT
Work Execution Time Quantity Cost in ( )
Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

CABINS - 1.5 TR 11 No 00.00


CABINS - 2 TR 6 No 00.00

2
• Supply of Hi-Wall INVERTER Type Split Air-Conditioners (Non-VRF) of following capacities - Make :
Carrier, Daikin, Hitachi, Toshiba SUPPLY of air cooled HIGH WALL MOUNTED Type air conditioning units
as specified; each unit shall comprise of separate Indoor and outdoor unit specified and as under:
• Indoor (fan coil) unit shall be Wall Mounted type comprising of Fan, Two way air discharge and 2 Row
Deep DX coil with finned copper tubes, T-Flow Fan unit with direct drive Motor; Unit shall have proper
insulated & leak proof condensate base connected. The outdoor (condensing unit) shall be of
Corrosion resistant Galvanized powder coated or equivalent Sheet steel low vibration assembly
installed on suitable vibration isolators and comprising of energy efficient
• Rotary / Reciprocating compressor with copper condenser coils only The units shall be installed on MS
angle iron frame welded structure (Sepatate item) with duly with anti-corrosive paint (Expoxy) -
Vibration Isolated pad with 2 side GI sheet. The above specified units shall be supplied as per following
schedule installed at locations as mentioned in the layout The unit will comparising of suitable
electrcial panal with capactior connector strip clamps etc. All machines shall be white in color
Note- Only wiring and cabling work to be done at stage 3 all other fittings, switches, and other
instruments should be fix at later defined stage.

32 www.axaguide.com
OTHER AIR CONDITIONER ANCILLARY WORK
Work Execution Time Quantity Cost in ( )
Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 100% 6-7 Days 450 R. ft. 00.00

3.1

• Copper piping work - Copper piping 21 gauge with 9mm superlon and 12mm insulation for cassette
A/c
• Totoline, Indigo make

33 www.axaguide.com
OTHER AIR CONDITIONER ANCILLARY WORK
Work Execution Time Quantity Cost in ( )
Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 90% 6-7 Days 550 Sq. Ft. 00.00

3.2

• Cabling work - Wiring 1.5sqmm 4 core flexible wire for indoor to outdoor
• Polycab make wire

34 www.axaguide.com
OTHER AIR CONDITIONER ANCILLARY WORK
Work Execution Time Quantity Cost in ( )
Area of Application
(%) (Days) (Sq. Ft.) (Approx.)

FRONT & BACK OFFICE 100% 6-7 Days 400 Sq. Ft. 00.00

3.3

• Drain pipe - Hydrolic flexible pipe for split ac and PVC drin pipe with 9mm insulation for cassette A/C
• Samson make

35 www.axaguide.com