Liebert® PDXTM and Liebert PCWTM

Compact Perimeter Cooling Solutions


Liebert® PDXTM and Liebert PCWTM
Compact Perimeter Cooling Solutions

Introducing thermal management solutions that efficiently lower your operating costs
and pack a lot of capacity into a small footprint.

Liebert PDX and Liebert PCW compact perimeter Options include


cooling solutions let you achieve the highest efficiency „„ Air Cooled (using the Liebert MC™
and protection with low capital, installation and Condenser); water/Glycool™;
maintenance costs. They replace the highly regarded dual cool; chilled water
and popular Liebert Challenger™ 3000 data center „„ Upflow, downflow, front &
cooling system, offering enhanced features including: side discharge
„„ Net capacity per footprint of up to 3.6kW per „„ Infrared and steam gen humidifiers
square foot – the industry's highest
„„ Electric reheat
„„ Industry's most compact footprint
„„ All 60 Hz 3-phase voltages
„„ Wide capacity range of 11kW – 29kW including 575V
„„ Compliance with U.S. Department of
Liebert iCOM™-S thermal system
Energy minimum efficiency standards for
3.0 control is available for optimizing the
data center equipment
performance of multiple cooling units
„„ High efficiency fans and compressors 2.5
and providing access to operational data,
„„ Hydrophillic slab coil 2.0 system diagnostics and trending.
SCOP

1.5 Liebert Liebert


Challenger PDX
Flexible Configurations 1.0
3000 Compact
System
Direct Expansion System Chilled
0.5 Water System
0.0
„„ Liebert PDX: 11kW, 18kW, 23kW, 29kW capacities (3, 5, „„ Liebert PCW
18kW Downflow:
with 18kW1kW,
with 17kW, 29kW
6.5, 8 Tons, respectively) capacities (3, 5, 8 Tons
fixed capacity respectively)
EC fans
fans

3.0 DX SYSTEM 20 CHILLED WATER


2.5 25% more efficient 16 SYSTEM
than the industry- Two times the
2.0 14 efficiency of the
standard Liebert
SCOP

Challenger 3000 Liebert industry-standard


SCOP

1.5 12
Liebert Liebert PCW Liebert Challenger
Challenger PDX 8.0 Compact 3000
1.0 System
3000 Compact Liebert
System 4.0 Challenger
0.5
3000
0.0 0.0
18kW with 17kW with 17kW with
18kW with
fixed capacity fixed capacity EC fans
EC fans
fans fans

20
SCOP (Sensible Coefficient of Performance)=Net Sensible Cooling Capacity/Total System Energy Consumption
16
2
14
Operate More Efficiently and Effectively

Ideal Applications Greater Protection


„„ Small and medium IT spaces „„ Self-optimizing features and advanced controls fine-tune
„„ Telecommunications switching offices system operations for fewer adverse events and longer
equipment life providing availability approaching 100%
„„ Industrial process control
„„ Liebert iCOM unit control provides access to system status,
„„ Laboratories and medical imaging suites
operations and event log and maintenance history
Higher Energy Efficiency „„ Advanced freeze and pressure routines to prevent icing on
coils and locked out compressors
„„ 25% more efficient than the industry-standard
Liebert Challenger 3000 in DX configuration and Lower Capital, Installation and
more than twice as efficient as the Liebert Challenger Maintenance Costs
3000 in chilled water configuration
„„ Liebert iCOM controls provide faster installation, easy
„„ Compliant with U.S. Department of Energy minimum event identification and self-optimization for mantaining
efficiency standards for data center equipment optimal performance without manual intervention.
„„ Industry-leading Liebert® iCOM™ unit control with „„ No fan belts to maintain and replace
advanced algorithms for air temperature and fan
„„ Easy access at front and side for faster servicing
speed coordination
„„ EC Fans reduce motor energy usage by 10-30%,
compared to standard AC motors. More efficient than
centrifugal blowers even when operating at 100%
fan speed
„„ Unique, floor-level air discharge configuration reduces
mix between hot and cold air, improving efficiency

More Efficient than the DOE


Minimum Efficiency Standards
2.55

2.45
Liebert
2.35 PDX
SCOP

Compact
2.25 System
18kW with
2.15 EC fans
2016 DOE
Standard
2.05

3
Direct Expansion Air-Cooled System PX011 PX018 PX023 PX029
Net Capacity Data - Std. Airflow - Upflow kBtuh (kW) kBtuh (kW) kBtuh (kW) kBtuh (kW)
75°F DB, 52°F DP (44.6% RH)
Total 44.0 (12.9) 62.3 (18.3) 80.7 (23.7) 95.4 (28.0)
Sensible 38.5 (11.3) 57.5 (16.9) 73.6 (21.6) 86.6 (25.4)
Fan Data
Std. Airflow, CFM (CMH) 1800 (3060) 2800 (4757) 3500 (5946) 4300 (7305)
Std. Fan Motor, HP (kW) 1.3 (1) 4.15 (3.1) 4.15 (3.1) 4.15 (3.1)
External Static Pressure, in. WG (Pa) 0.8 (199) 0.8 (199) 1 (249) 1 (249)

Chilled Water Sytem PW011 PW017 PW029


Net Capacity Data - Std. Airflow - Upflow kBtuh (kW) kBtuh (kW) kBtuh (kW)
75°F DB, 52°F DP (44.6% RH), 45°F EWT, 55°F LWT
Total 38.9 (11.4) 53.8 (15.8) 87.4 (25.6)
Sensible 34.5 (10.1) 52.8 (15.5) 82.2 (24.1)
Flow Rate, GPM (l/m) 8.0 (30.3) 11.9 (45) 19.4 (73)
Unit Pressure Drop, ft. of water (kPa) 8.2 (24.5) 8.4 (25.1) 13.1 (39.3)
Fan Data (3.1kW EC Blower)
Std. Airflow, CFM (CMH) 1800 (3060) 3500 (5946) 4300 (7305)
Std. Fan Motor, HP (kW) 1.3 (1) 4.15 (3.1) 4.15 (3.1)
External Static Pressure, in. WG (Pa) 0.8 (199) 0.8 (199) 1 (249)

Emerson Network Power – Global Headquarters 24x7 Tech Support


1050 Dearborn Drive 800 877 9222 Phone (U.S. & Canada Only) 800 222 5877 Phone (U.S. & Canada Only)
P.O. Box 29186 614 888 0246 Phone (Outside U.S.) 614 841 6755 Phone (Outside U.S.)
Columbus, Ohio 43229 Contact@EmersonNetworkPower.com

EmersonNetworkPower.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors
or omissions. © 2016 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert is
a registered trademark of the Liebert Corporation. Emerson, Consider it Solved, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2016 Emerson Electric Co

SL-19825 (04/16) Printed in USA