Technical features
Medium: Mounting: Ambient/Media temperature: Materials:
Compressed air, 40 µm filtered, On sub-bases -15 ... +50°C (+5 ... 122°F) Body: die-cast aluminium
lubricated or non-lubricated Sizes: Air supply must be dry enough to Spool & sleeve: hard anodised
Operation: ISO 1 and 3 avoid ice formation at temperatures aluminium with special PTFE
Glandless spool valve, solenoid Operating pressure: below +2°C (+35°F). coating
actuatedand spool position -0,9 ... 16 bar max. Seals: NBR
sensing (-13,1 ... 232 psi max.) Locking plate: die-cast zinc or steel
blue zinc coated
Screws: steel, blue zinc coated
Plastic parts: POM
Electrical details for solenoid operators Electrical details for proximity switches
Voltage tolerance ± 10% Supply voltage 10 ... 30 V d.c.
Rating 100% continuous duty Output current ≤ 200 mA
Inlet orifice 1,0 mm Switching output PNP
Electrical connection EN 175301-803 - Form A, 30 mm Output function NO
Solenoid coil mounting 3 positions x 90°, not in place of sensor Electrical connection ISO 1 M8 x 1 - 3-pin
Manual override Push only (brass) ISO 3 M12 x 1 - 4-pin
Protection class IP65 (with sealed plug) Note: The proximity switches must not be altered or replaced.
Improper installation could lead to malfunction.
Please contact IMI Precision Engineering.
0570275
Our policy is one of continued research and development. We therefore reserve the right to amend, 2/19
without notice, the specifications given in this document. (2014 - S5109g) © 2015 IMI International s.r.o. SP/en 5.2.500.01
ISO* STAR (SXE) 5/2 (with spool position sensing)
Solenoid actuated glandless spool valves
Sub-bases, end plates and blanking disc - VDMA 24345 sub-base options
Single station sub-base, Single station Modular sub-base Form D Blanking disc
Form A sub-base Form B Form C End plates for VDMA
side ported bottom ported sub-bases
Accessories
Blanking plate Transition plate Sandwich plate with Flow regulator plate,
for VDMA and universal sub-bases for VDMA sub-bases check valves ports 3 and 5 regulated
ISO Page 4
size Page 4 Page 5 Page 5
1 CQM/22152/3/23 CQM/22152/3/24 (1 » 2) FP7050 –
3 CQM/22354/3/23 FP8570 (1 » 3) FP7070 CQM/22354/3/26
Drawings A Dimensions in mm
Projection/First angle
A
4 3
C
D
S
F
E
1
P
M8x1
F Q
E
P B
Pin Nr. Function
Q
B J 1 L + (brown)
3 M - (blue) Ground
J 4 Q - (black) Closer
H
M
G
H
M
G
K R
1 O Pin assignment ISO 3
K R
4 3
1 O
1 Manual override 4 3
ISO size A B C D E F G H J K M O P Q R S kg
1 137,5 128 98 33 7,5 M5 42 32 36 18 28 42 88 118,5 13,5 62 0,26
1 2
3 181 167 108 43 11,5 M8 62,5 32 64 32 48 65,5 135,5 158 15,5 78,5 0.70
M12x1
1 2
M12x1 Pin Nr. Function
1 L + (brown)
2 Not connected
3 M - (blue) Ground
4 Q (black) Closer
Our policy is one of continued research and development. We therefore reserve the right to amend,
SP/en 5.2.500.02 without notice, the specifications given in this document. (2014 - S5109g) © 2015 IMI International s.r.o. 2/19
ISO* STAR (SXE) 5/2 (with spool position sensing)
Solenoid actuated glandless spool valves
14 5 3 12
4 2
1
d2
L10
L10
L9
L7
L9
L7
L8
L6
L1
L1
L6
L8
1
d2
d3
2 4
12 3 5 14
d3
h4 b h3 d4 h3 b1
h1 b h2 b2
h1
14 14
5 5
4
L5
1
L1
1
L
H
J
2
L5
3 3
12 12
d6 E F h3
G C h4
Our policy is one of continued research and development. We therefore reserve the right to amend,
2/19 without notice, the specifications given in this document. (2014 - S5109g) © 2015 IMI International s.r.o. SP/en 5.2.500.03
ISO* STAR (SXE) 5/2 (with spool position sensing)
Solenoid actuated glandless spool valves
Blanking plate for VDMA & universal Silencer for VDMA & universal Dimensions in mm
Projection/First angle
sub-bases with ISO G and NPT threads sub-bases with ISO G and NPT threads
h1 b
h3 h2
Transition plate from ISO 1 » ISO 2, ISO 2 » ISO 3 and Blanking disc
ISO1 » ISO 3 for VDMA sub-bases for ISO G FP8582 for ISO G thread
A
1
14 14
5 5
A
1 1
B
3 12 12 3
3 Poppet valves 3400 3,4 3 ... 8 43,5 ... 116 2,05 FP7070
5 3
1
Application: Note:
With this type of intermediate plate together with a 5/3-way valve, center position Metal to metal sealed spool and sleeve valves have always a small amount of leak
open, a piston movment can be stopped in any desired position. This position will because of its design. Therefore 5/3-way valves, center position closed, are only
kept during a long period. applicable for short stops.
Caution: Not suitable for safety applications!
Our policy is one of continued research and development. We therefore reserve the right to amend,
SP/en 5.2.500.04 without notice, the specifications given in this document. (2014 - S5109g) © 2015 IMI International s.r.o. 2/19
ISO* STAR (SXE) 5/2 (with spool position sensing)
Solenoid actuated glandless spool valves
Dimensions Dimensions in mm
Projection/First angle
A
ISO A B C Model
1 96 42 52 FP7050
B
3 165 62 95 FP7070
5 3
1
Application: Note:
Regulation of exhaust ports 3 and 5 allows easy cylinder speed control The regulator screw can be locked with the lock nut.
24
3500
3000
Exhaust flow
2500
(port 3 + 5)
29
2000 1
18,5
1500 2
1000
500 4 2
63,5
0 14 12
0 1 2 3 4 5 6 7 8 9 10
Number of turns from closed
1 Fully open
141
2 Fully closed
EN - Englisch
Warning
These products are intended for use in industrial compressed air systems Through misuse, age, or malfunction, components used in fluid power
only. Do not use these products where pressures and temperatures can systems can fail in various modes. The system designer is warned to
exceed those listed under »Technical features/data«. consider the failure modes of all component parts used in fluid power
Before using these products with fluids other than those specified, for systems and to provide adequate safeguards to prevent personal injury
non-industrial applications, life-support systems or other applications not or damage to equipment in the event of such failure.
within published specifications, consult System designers must provide a warning to end users in the system
IMI Precision Engineering, IMI International s.r.o. instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings
found in instruction sheets packed and shipped with these products.
Our policy is one of continued research and development. We therefore reserve the right to amend,
2/19 without notice, the specifications given in this document. (2014 - S5109g) © 2015 IMI International s.r.o. SP/en 5.2.500.05