TECHNICAL DATASHEET

Revsion 4 May 2022

SR COAT PUD
PUD Waterproofing Coating

Product Description While applying SR Coat PUD over aluminum sandwich


panel or corrugated sheets, make sure that all the
SR Coat PUD is a liquid applied waterproofing and joints are riveted properly, and rusted sheets replaced.
protective coating for concrete structures based on
hybrid polyurethane. This hybrid coating system is Any substrate to receive SR Coat PUD should be
formulated with high quality polyurethane polymers completely dry. Entrapped moistures will lead to
and fillers to form a superior waterproofing coating. bubble formation and even delamination from the
substrate. SR Coat PUD is resistant to light foot traffic.
Product Features However, heavy traffic, furniture’s etc. will damage the
coating. In such situation the coating should be protect-
• Environmentally friendly ed with tiles or other suitable means.
• Low VOC
• Easy to apply Mixing
• Excellent crack bridging properties
SR Coat PUD is a single component product, mix the
• Excellent UV resistance, weatherability and
product thoroughly prior to the application. A slow
color retention properties
speed drill and suitable paddle mixer shall be used to
• Excellent resistance to water and vapor avoid formation of air bubbles.
• Single component
Application
Uses
Priming:
Used as a waterproofing and protective coating for For porous substrate dilute SR Coat PUD with equal
the following structures: amount of water and apply as primer coat and allows
• Waterproofing of roofs, terraces, balconies, and to dry. The coating can be applied with a brush, roller
domes or airless spray and shall be applied in a minimum of
2 coats. The first coat shall be completely dry before
• Wet area waterproofing
applying the second coat. The second shall be applied
• Protective coating on exposed concrete surfaces.
cross wise to the first coat.
• Aluminum sandwich panel and corrugated sheet
waterproofing. Application procedure may be vary slightly depending
upon the site conditions. The general recommended
Coverage
guidelines for the application of the coating systems is
1L/ M2/Coat (Minimum 2 coats recommended) as follows: It is recommended to apply SR Coat PUD in
two coats. Critical areas like pipe penetrations and
Packing corners to be treated first. Apply one coat of SR Coat
PUD with a brush on all corners and around the pipe
20 Ltr Pail (Single Component) penetrations extending up to 200mm on either sides
and reinforce with a fibre mesh/ geo textile. Apply a
Color
second coat over it and allow to dry. Then apply first
White/ Grey coat of SR Coat PUD by brush or roller over the entire
area at 1 Ltr/ Sq.M. A second coat to be applied at
Surface Preparation
right angles to the first coat at 1 Ltr/ Sq.M. after the
The surface must be structurally sound and free of oil, first coat is dry. The coating is to be left to cure for a
grease, dust, and other contaminants which will affect minimum of 72 hours. Flood test should be carried out
the adhesion. Rotary wire brush or light grinding only after four days.
should be employed to prepare the substrate. Minor
honeycombs and potholes up to 5mm shall be
repaired with cementitious mortar.

Manufactured by,
Smart Insulation Finishing Systems LLC/ Po Box 3350 / UAQ / Tel:+97167064333/ Toll Free 800 LEAK / www.sifs.me
ISO 9001: 2015/ ISO 14001:2015 / ISO 45001:2018 Certified Company
TECHNICAL DATASHEET
Revsion 4 May 2022

Technical Data

PROPERTIES TEST METHOD TEST RESULT


Appearance Viscous liquid
Density (g/cc) ASTM D 1475 1.0 ± 0.1
Tensile strength# ASTM D 412 >1
Elongation# ASTM D 412 >200%
Solid content ASTM D 1644 55 %- 60%
VOC (g/l) ASTM D 3960 <20
Shore A hardness ASTM D 2240 40 -50

SRI (white color) ASTM E 1980 >80


Solar reflectance EN 410 >75
Emissivity EN 673 <1
VOC (g/l) ASTM D 3960/D 2369 <50
Full cure - 7 days
Service temperature - 5ºC to 70ºC

All values given are subject to 5 – 10% tolerance


# Values achieved within 48 hours after casting specimen

Storage SR Coat PUD should not be applied on external


surface where aesthetic appearance is critical as the
Store away from ditrct sunlight and extreme tempera-
difference in drying rate my cause slight color differ-
tures. Liquid should not be allowed to freeze. The shelf
ences.
life is up to 12 months when stored as per recommenda-
tions and in unopened conditions. Health & Safety
Limitations As will all construction chemical products caution should
Do not proceed with application on external areas always be exercised. Protective clothing such as gloves and
when rainfall is imminent . goggles shall be worn. Treat any splashes to the skin or
Do not apply over light weight concrete or foam eyes with fresh water immediately. Should any of the pro-
concrete. ducts be accidentally swallowed, do not induce vomiting,
but call for medical assistance immediately.

Notes:
All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Please note
that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact
description of the application fields.Information on this datasheet is subject to change without notice and should not be used for writing specification. For additional
information on specific applications,please contact Smart Insulation Finishing System LLC.The information contained herein, particularly recommendations for the handling
and use of our products, is based on our professional experience.as materials and conditions may vary with each intended application, and thus are beyond our sphere
of influence, we strongly recommend that in each case sufficient tests are conducted to check the suitability of our products for their intended use. legal liability cannot
be accepted on the basis of the contents of this data sheet or any verbal advice given, unless there is a case of wilful misconduct or gross negligence on our part. this
technical data sheet supersedes all previous editions relevant to this product. Sifs reserves the right to change the properties of its products. The proprietary rights of third
parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product
Data Sheet for the product concerned, copies of which will be supplied on request.

Manufactured by,
Smart Insulation Finishing Systems LLC/ Po Box 3350 / UAQ / Tel:+97167064333/ Toll Free 800 LEAK / www.sifs.me
ISO 9001: 2015/ ISO 14001:2015 / ISO 45001:2018 Certified Company

You might also like