Kawamoto_WUO_Non-clog Vortex
Kawamoto_WUO_Non-clog Vortex
life
Long
High nce
rma
Perfo
r
Neve
ru s t
body
Lowered
Changed from failure risk
Relay to TRIAC on electric
parts
WUP(4) WUO(4)
50mm only
Object passability Unit: mm Object passability Unit: mm
Bore Bore
Size of object Size of object
40mm in 2.2kW model
High blade impeller (PAT.) brings high performance Float switches become
and a large object passage. easy to adjust position.
The position of stop float
is un-adjustable.
High
Hard
ly The lowest opeartion level
Ma clogg
enha x. 15% become 10mm lower than
nced
TDH previous model.
(please refer to the list in later
pages for actual level.)
Conventional Impeller
Built in Auto-cut prevents over load and motor burning.
All blades are same height
Double mechanical seal stops water immerge to motor.
Selection chart
Capacity (m3/min)
Specification table
Selection chart
Capacity (m3/min)
Specification table
Automatic type
Manual type Automatic type
(alternate/parallel)
For sewage
Selection chart
Capacity (m3/min)
Specification table
MODEL NAME MOTOR SPECIFICATION
Ref. Bore Automatic
Manual Automatic (Alternate/paralell) ph. kW m3/min m m3/min m
LN type is available for alternate/parallel operation when using together with L type.
Actual model names in above list with *1~3 on nameplate are as follows:
*1 WUO-505/655-1.5T4(L/LN)-F *2 WUO-655/805-2.2T4(L/LN)-F *3 WUO-655/805-3.7T4(L/LN)-F
Selection chart
Capacity (m3/min)
Specification table
MODEL NAME MOTOR SPECIFICATION
Ref. Bore Automatic
Manual Automatic (Alternate/paralell) ph. kW m3/min m m3/min m
LN type is available for alternate/parallel operation when using together with L type.
Actual model name of models in above list with *1~3 on nameplate are as follows:
*1 WUO-506/656-1.5T4(L/LN)-F *2 WUO-656/806-2.2T4(L/LN)-F *3 WUO-656/806-3.7T4(L/LN)-F
Dimensional reference Before actural planing, please inquire technical drawing.
Always read the manual thoroughly and fully comprehend the contents for safe operation before starting use.Precautions for using
Important Safety Precautions products safely and for preventing personal injuries or physical damage are given in the manual. ※We bear no responsibility when
the above listed precautions are not observed.
■ Matters falling under the following may not be covered by the warranty: uses out The life of the creature could be affected.
of the specified scope of application, failure to comply with precautions, improper ■ Conduct construction in accordance with the applicable laws and regulations
repairs and alterations, matters arising from natural disasters, matters arising (the Technical Standards of Electric Installation, interior wiring regulation, Building
from the installation environment (improper power source, foreign objects, sand Standards Act, etc.). Not only does it violate the laws and regulations, but it also
etc.), non-compliance with laws and regulations or standards pertaining thereto, may cause injuries due to electric shock, fire, falling and tipping over.
accidental or intentional damage or injury, replacement of consumable parts,
■ Do not use in places where people are assumed to get in contact with the product
defects due to resale, etc.
(baths, pools, lakes, etc.). Electric leak may occur and cause electric shock.
■ Do not use the product for applications out of the product specifications. Doing
■ Depending on the equipment, attach a filter etc. appropriate for your application
so may cause electrical shock, fire, liquid leakage, etc.
on the discharge side before use, perform thorough flushing and check that there
■ Close attention is needed when rusting, corrosion/erosion are not permissible is no contamination. Cutting oil, rubber mold releasing agent, foreign objects etc.
owing to the application or liquid properties. from the manufacturing line and cutting oil, foreign objects etc. from the pipeline
■ Take into account both the pump and the rest of the equipment when considering may contaminate the liquid which is to be handled.
and selecting. ■ Do not operate pumps with a specification of 50 Hz at 60 Hz. Damage may arise
■ Select a product which is appropriate for your application. Inappropriate use of as a result of excess pressure or burnout of the motor etc. due to overload.
products may cause accidents. ■ The Pump should never be disassembled, repaired, or modified, or the power
■ When using this pump for living things (fishery, fish tank, aquarium, etc.) or cable should never be replaced by anyone other than a qualified repair technician.
important equipment, always prepare a spare unit. If the pump fails, an oxygen Improper repairs could result in electric shocks, fires, faults or break. It is
deficiency or degradation of water quality, etc., could occur and affect the recommended that both periodic and daily inspections be performed in order to
creature's life. ensure that the pump will operate reliably for as long as possible.
■ If used to transport food-related items, give due consideration to the materials ■ Failure to perform inspections may lead to pump failure, accidents etc.
used. Contamination by foreign objects may occur. ■ For periodic inspections, please consult your distributor or our nearest sales
■ Avoid using this product with living things that are susceptible to copper alloys. office.