MCR 220 S

Acrylic urethane topcoat for marine structures


Product Properties
 2-component, acrylic urethane semi-gloss topcoat
 Self-leafing glass flakes for increased impermeability
 Tough, durable finish with good UV resistance
 Excellent chemical and abrasion resistance

Areas of Application
 Protective coating for marine, industrial and aggressive environments
 Ideal for structures in above tidal zone areas
 Suitable for structural steel and concrete, piping, cranes, mechanical equipment, bridges, storage exteriors,
chemical plants

Application
Substrate Preparation Overcoating
The substrate must be clean and free from all loose If overcoating time exceeds 24 hours and
particles, dust, oil, suspected salt and any contamination has occurred, clean the surface using
contaminant which may affect adhesion. If required, a detergent solution or fresh water and allow to dry
clean all surfaces with water soluble, environment before continuing. If maximum overcoating time is
friendly degreaser mixed with clean, fresh water. exceeded, abrade the surface and wash down with
Allow surface to dry before commencing main fresh water to remove contamination and allow to dry.
preparation.
General Information
Mixing Coverage rates and consumption can vary depending
Using a drill mixer, mix component A briefly. Then on application method, temperature, profile and
pour in component B and mix until homogeneity is porosity of the substrate.
obtained. Re-pot, making sure material in corners of
container is emptied completely and mix again. (Do Before application please read the safety information
not mix part sets) given on packing label and in the leaflet "Safety
Measures for Handling Solvent Containing Coating
Application Substances and Chemically Reactive Resins".
MCR 220S is a topcoat and is applied over MCR
primers or intermediate coats, such as MCR 130S. It
can be applied by airless spray, conventional spray,
brush or roller.

A) Airless Spray
Output Fluid Pressure : 2000 -2500 psi
Tip Size : 13 -18 thou
o o
Fan Angle : 30 - 65
An addition of up to 5% MCR Thinner No 5 is allowed
for lower film build.

B) Conventional Spray
An addition of up to 10% of MCR Thinner No 5 is
required. Maximum DFT by this method is 75µm.

C) Brush / Roller
Use suitable brush or roller.

_______________________________________________________________________________________________________________________________________________________________

Marketed by :
MC Bauchemie (Malaysia) Sdn Bhd (386385-M)
Lot S113, 2nd Floor, Centrepoint, No.3 Lebuh Bandar Utama, Bandar Utama, 47800 Petaling Jaya, Selangor, Malaysia
Tel: +603 7728 1233 Fax: +603 7728 6833 Email : enquiry@mc-bauchemie.com.my
Technical Data for MCR 220 S
Characteristics Unit Value Comments
Mixing Ratio p.b.v 9:1 base : hardener
Solids Content % ~ 58 by volume
3
Density kg/dm 1.4 – 1.6 mixed, depending on colour
2
Coverage litre/m 0.10 at 50 µm DFT
o
Pot Life hours ~4 at 18 C
Curing Time
o o
- Dust Free mins 90 / 45 at 18 C / 30 C
o o
- Hard Dry hours 4/2 at 18 C / 30 C
o o
- Overcoating (min) hours 16 / 12 at 18 C / 30 C
o o
- Overcoating (max) days indefinite at 18 C / 30 C
Flash Point °C 21 - 32 mixed material, depending on colour
Application Conditions °C > 5; < 40 air, material and substrate temp.
% < 90 relative humidity (RH)
°C 3 above dew point

Product Characteristics for MCR 220 S


Cleaning Agent MCR Thinner No 5
Colour Available in wide range of colours / Mid Sheen
Delivery 5 litre set
Storage Can be stored in cool and dry conditions for 12 months in original
unopened packs.
Disposal In the interest of the environment, please empty all packs completely
& dispose in accordance with local regulations.

Safety Advice
Please take notice of the safety information and advice given on the packaging labels and safety information sheets
and please take notice of the leaflet, “Safety Measures for Handling Coating Materials and Reactive Resins”.

Note: Bespoke vendor supplies. The information on this data sheet is based on our experiences and correct to the best of our knowledge. It is,
however, not binding. It has to be adjusted to the individual structure, application purpose and especially to local conditions. Our data refers to the
accepted engineering rules, which have to observe during application. This provided we are liable for the correctness of this data within the scope
of our terms and conditions of sale-delivery-and-service. Recommendations of our employees which differ from the data contained in our
information sheets are only binding if given in written form. The accepted engineering rules must be observed at all times.

Edition 05/15. Some technical changes have been made to this print medium. Older editions are invalid and may not be used anymore. If a
technically revised new edition is issued, this edition becomes invalid.