Download as pdf or txt
Download as pdf or txt
You are on page 1of 132

AirSol

LS Cable has developed the relevant products and solutions for the airport . In the runway,
the primary circuit cables run under the ground to power lamps which guide the pilot.
And in the airport terminal, communication cables such as optical fiber and copper cables are
used to transfer data and signal with high performance.
LS Cable have supplies full range of power cable to cover any airport's power consumption as
any requirement under any time.

Contents 1. Runway
1.1 RG : Runway Ground Lighting
1.2 RA : Runway Aircraft Powering

2. Airport Terminal
2.1 AT-C : Communication
2.2 AT-E : Emergency
2.3 AT-P : Public Lighting
2.4 AT-V : VFD
2.5 AT-B : Busduct

3. Baggage Handling System


3.1 BH-C : Control
3.2 BH-Co : Communication
3.3 BH-P : Power

4. Power Infra
4.1 PI-P : Power
4.2 PI-J : Joints

5. Bridge
5.1 BR-PC : Power & Control
5.2 BR-C : Carpet

6. Air Rail
6.1 AR-P : Power
6.2 AR-R : Rail

7. The Others
7.1 TO-F : Flooring
7.2 TO-HS : Heat Shrinkable Tube
7.3 TO-HC : Heating Cable
7.4 TO-CT : Cables Tube
7.5 TO-LED : LED Lighting
Application Business
The Leading Solution Provider, LS Cable introduced a new maketing concept, which is providing
collected items applicable to an industry as a package instead of separately providing a single item.
This LS Cable’s business solutions are applicable to following industries : Wind Power Generation,
Railway & Rolling stock, Airport, Power Transmission & distribution, Marine & Offshore, and Automotive.
The Application Business manages various departments and their products to satisfy our customersspecific needs
and convenience.
1. Runway

1
Runway
Runway
1.1 RG: Runway Ground Lighting
Primary Circuit
RG-P3/6kV 4
RG-P5kV-S 5
RG-P5kV 6
RG-P6kV-7 7
RG-P6kV-TA 8
RG-P6kV-2S 9
Secondary Circuit
RG-S450V 10
RG-S500V 11
Ground Earth
RG-G 12
Monitor
RG-CR4(UL2919-AMESB) 13

1.2 RA: Runway Aircraft Powering


400Hz Power
RA-P600V-3C 16
RA-P600V-4C 17
Connector
RA-C 18
Runway Ground Lighting Aircraft Powering

AirSolTM 1.1 Runway Ground Lighting


Primary Circuit Cable

Max. Insulation Bending


Outer Material of
Voltage Temperature Cross Section Thickness Screening Armouring Radius Weight Page
Sheath Conductor
( ) (mm )2
(mm) [mm] (kg/km)

Bare or
1/2 90 1x6 PVC, 1.5 PVC - 150, 195 170
Helix Cu
4
2.5/5 Bare or
90 1x6 PVC, 3.0 PVC - 150, 195 250
3/6kV Helix Cu

1x6, PE, PVC, Copper or 156~180


XLPE, 2.3 - 10D, 20D 5
1x8 AWG XLPE Brass Tape 180~218
Primary 5kV 90 Copper
Circuit 1x6, 156~170
Cable XLPE, 2.3 PE,PVC - - 10D, 20D Class 2 6
1x8 AWG 180~211

- 235 420 7
Bare or
90 1x6 XLPE, 3.5 PVC Steel Wires,
Helix Cu 310 710 8
6/10kV Helix

Double Cu 310, 410,


90 1x6 XLPE, 3.5 PVC - 9
Tapes 10D, 20D 405

Max. Current Outer diameter Bending


Outer Material of
Voltage Temperature Cross Section Rating Volt Drop Range Radius Weight Page
Sheath Conductor
( ) (mm2) (A) (V/A km) (mm) (mm) (kg/km)

1x2.5~6 32~56 5.9~14.0 6.3~9.8 66~109

Cross Install :
Linked Oil 6 to 8x
450/750V 85 2x2.5~6 32~56 6.7~16.2 10.2~17.0 161~279 10
Resistant Out
Elastomer Diameter
Secondary 3x2.5~6 32~56 7.0~16.2 10.9~18.0 195~346
Copper
Circuit
Cable Class 5
After
Cross Install :
Linked 10mm
500V 90 2x4 - Synthetic - - 167 11
Rubber Before
Compound Install :
50mm

1.1 RG : Runway Ground Lighting AirSolTM 1.Runway 3


Runway Ground Lighting Aircraft Powering

AirSolTM RG-P3/6kV
Primary Circuit Cable

Application
Buried under runway, MV cable series circuit
Connecting the CCR (Constant Current Regulator) and the transformers
and between the isolating transformers.

Design Standard
ENV 50213 (European pre-standard)
IEC60502-2

Construction Technical Data


Conductor Solid bare copper Rated Voltage 1/2kV, 2.5/5kV, 3/6kV
Insulation PVC Temperature -40~90
Tape Optional Bending Radius 150mm, 195mm
Screen Concentric layer of bare copper wires Test Voltage 11kV/5min.
counter helix of a copper tape
Outer Sheath PVC
Color Black, Red

Product List
Cross Section Insulation Thickness Cross Section of screen Outer Diameter Weight
Voltage
(mm2) (mm) (mm2) (mm) (kg/km)
1/2kV 6 1.5 2.5 10.0 170
2.5/5kV, 3/6kV 6 3.0 4 13.0 250

Other dimensions available on enquiry.

4 AirSolTM 1.Runway 1.1 RG : Runway Ground Lighting


Runway Ground Lighting Aircraft Powering

AirSolTM RG-P5kV-S
Primary Circuit Cable

Application
Buried under runway, MV cable series circuit
Connecting the CCR (Constant Current Regulator) and the isolating transformers
and between the isolating transformers.

Design Standard
Adapted to FAA L-824 Type C

Construction
Conductor Stranded bare copper or tinned copper, Class 2
Semi Conductor Extruded
Insulation XLPE Technical Data
Semi Conductor Tape or extruded Rated Voltage 5 kV
Screen Copper or brass tape(s) Temperature -20~70
Outer Sheath PE, PVC, XLPE Bending Radius Static 10D (Dynamic 20D)
Color Black, others on request Test Voltage 11kV/5min.

Product List
Insulation Thickness Tape Thickness Weight
Cross Section Screen Material Outer Sheath
(mm) (mm) (kg/km)
6(mm2) 2.3 Brass Tape 0.08 XLPE 156
6(mm2) 2.3 Brass Tape 0.08 PVC 170
6(mm2) 2.3 Brass Tape 0.08 PE 156
6(mm2) 2.3 Copper Tape 0.10 XLPE 164
6(mm2) 2.3 Copper Tape 0.10 PVC 180
6(mm2) 2.3 Copper Tape 0.10 PE 164
8 AWG 2.3 Brass Tape 0.08 XLPE 180
8 AWG 2.3 Brass Tape 0.08 PVC 211
8 AWG 2.3 Brass Tape 0.08 PE 180
8 AWG 2.3 Copper Tape 0.10 XLPE 187
8 AWG 2.3 Copper Tape 0.10 PVC 218
8 AWG 2.3 Copper Tape 0.10 PE 187

Other dimensions available on enquiry.

1.1 RG : Runway Ground Lighting AirSolTM 1.Runway 5


Runway Ground Lighting Aircraft Powering

AirSolTM RG-P5kV
Primary Circuit Cable

Application
Buried under runway, MV cable series circuit
Connecting the CCR (Constant Current Regulator) and the transformers
and between the isolating transformers

Design Standard
Adapted to FAA L-824 Type C

Construction Technical Data


Conductor Stranded bare or tinned copper, Class 2 Rated Voltage 5kV
Insulation XLPE Temperature -20~70
Outer Sheath PVC Bending Radius Static 10D (Dynamic 20D)
Color Black, others colours on request Test Voltage 11kV/5min.

Product List
Insulation Thickness Outer Sheath Thickness Outer Diameter Weight
Cross Section Outer Sheath
(mm) (mm) (mm) (kg/km)
6(mm2) 2.3 0.8 11.0 PVC 156
6(mm2) 2.3 0.8 11.0 PE 170
8AWG 2.3 0.8 11.5 PVC 180
8AWG 2.3 0.8 11.5 PE 211

Other dimensions available on enquiry.

6 AirSolTM 1.Runway 1.1 RG : Runway Ground Lighting


Runway Ground Lighting Aircraft Powering

AirSolTM RG-P6kV-7
Primary Circuit Cable

Application
Buried under runway, MV cable series circuit
Connecting the CCR (Constant Current Regulator) and the transformers
and between the isolating transformers.

Design Standard
ENV 50213 (European pre-standard)
IEC 60502-2

Construction Technical Data


Conductor Stranded bare copper (RM), Class 2 (7wires) Rated Voltage 6/10kV
Insulation Extruded triple dielectric of internal semi-conductor, Temperature -40~90 , (Max core temperature : 90 )
natural colored cross-linked polyethylen Bending Radius 235mm
Insulation & external semi-conductor (Strippable) Test Voltage 15kV/5min.
Screen Concentric layer of bare copper wires, counter
helix of a copper tape
Outer Sheath PVC
Color Red

Product List
Thickness of external
Cross Section Insulation Thickness Semi Conductor Thickness of sheath Outer Diameter Weight
(mm2) (mm) (mm) (mm) (mm) (kg/km)
6 3.5 0.4 2.8 15.6 420

Other dimensions available on enquiry.

1.1 RG : Runway Ground Lighting AirSolTM 1.Runway 7


Runway Ground Lighting Aircraft Powering

AirSolTM RG-P6kV-TA
Primary Circuit Cable

Application
Buried under runway, MV cable series circuit
Connecting the CCR (Constant Current Regulator) and the Transformers
and between the isolating transformers.

Design Standard
ENV 50213 (European pre-standard)
IEC 60502-2

Construction Technical Data


Conductor Bare copper, Class 2 Rated Voltage 6/10kV
Insulation Extruded triple dielectric of internal semi-conductor Temperature -40~90 , (Max. core temperature : 90 )
natural colored cross-linked Polyethylen Insulation & Bending Radius 310mm (Armouring)
external semi-conductor (strippable) Test Voltage 15kV/5min.
Screen Concentric layer of bare copper wires, Counter
helix of a copper tape
Sheath PVC
Color Red
Armouring Steel wires, layed in a helix
Outer Sheath PVC

Product List
Thickness of External Diameter of Steel Outer Sheath
Cross Section Insulation Thickness Semi Conductor Outer Diameter Wires Thickness Weight
(mm2) (mm) (mm) (mm) (mm) (mm) (kg/km)
6 3.5 0.4 20.5 0.9 1.4 710

Other dimensions available on enquiry/Armouring : with the risk of mechanical damage

8 AirSolTM 1.Runway 1.1 RG : Runway Ground Lighting


Runway Ground Lighting Aircraft Powering

AirSolTM RG-P6kV-2S
Primary Circuit Cable

Application
Buried under runway, MV cable series circuit
Connecting the CCR (Constant Current Regulator) and the transformers
and between the isolating transformers.

Design Standard
Adapted to UNE 21-161-93 (Spain)

Construction Technical Data


Conductor Bare copper , Class 2 (7 wires) Rated Voltage 6/10kV
Insulation Extruded triple dielectric of internal semiconductor Temperature -20~90
Natural colored cross-linked polyethylen Bending radius 310mm
Insulation & external semi-conductor(strippable) Test Voltage 15kV/5min.
Screen 2 Overlapped copper tapes
Outer Sheath PVC / Halogen-free flame retardant compound

Product List
Thickness of External
Cross Section Insulation Thickness Semi Conductor Thickness of Sheath Outer Diameter Weight
(mm2) (mm) (mm) (mm) (mm) (kg/km)
6 3.5 0.4 2.8 19 405

Other dimensions available on enquiry.

1.1 RG : Runway Ground Lighting AirSolTM 1.Runway 9


Runway Ground Lighting Aircraft Powering

AirSolTM RG-S450V
Secondary Circuit Cable

Application
Buried under runway, LV cable circuit
Connection between transformers & airfield lighting equipment.
Airfield lighting cable for secondary electrical circuits

Design Standard
NF C 32-102-4, HD 22-4

Construction Technical Data


Conductor Flexible bare copper, Class 5 Rated voltage 450/750V
Insulation Special cross linked elastomer Temperature -20~85
Outer Sheath Cross linked oil resistant elastomer For movable installation : 6 to 8 x Outer diameter
Color Black Bending Radius For 3 x Outer diameter if 12mm
Core 2 cores : Brown + blue, fixed installations 4 x Outer diameter if 12mm
Identification 3 cores : Brown + blue + green/yellow

Product List
Cross Section Current Rating Outer Diameter Voltage Drop Weight
(mm2) (A) (mm) (V/A km) (kg/km)
1x2.5 32 6.3~7.9 14 66
1x4 43 7.2~9.0 8.7 94
1x6 56 7.9~9.8 5.9 109
2x2.5 32 10.2~13.1 16.2 161
2x4 43 11.8~15.0 10.1 238
2x6 56 13.1~17.0 6.7 279
3x2.5 32 10.9~14.0 16.2 195
3x4 43 12.7~16.2 10.1 290
3x6 56 14.1~18.0 7.0 346

Other dimensions available on enquiry.

10 AirSolTM 1.Runway 1.1 RG : Runway Ground Lighting


Runway Ground Lighting Aircraft Powering

AirSolTM RG-S500V
Secondary Circuit Cable

Application
Airfield lighting cable for secondary electrical circuits.

Construction
Conductor Tinned copper, Class 5
Insulation Cross linked polyalkene
Separator PTEF-foil
Outer Sheath Cross linked synthetic rubber

Technical Data
Rated Voltage 500V
Temperature -20~90 (Max. 170 for 5 hours)
Bending Radius Fixed installation-10mm
Flexible Used 50mm

Product List
Insulation Thickness Outer Sheath Thickness Outer Diameter Weight
Cross Section
(mm) (mm) (mm) (kg/km)

2x4(mm2) 0.5 1.1 9.8 167

Other dimensions available on enquiry.

1.1 RG : Runway Ground Lighting AirSolTM 1.Runway 11


Runway Ground Lighting Aircraft Powering

AirSolTM RG-G
Earth Wire

Application
Panel wiring, domestic & industrial indoor

Design Standard
International HD 21.3
National NBN C32-123

Construction Technical Data


Conductor Copper Rated Voltage 450/750V
Flexibility Stranded Current Rating 472 A
Conductor Shape Round, stranded Temperature 0~60
Insulation PVC Voltage Drop 0.21 V/A.km
Chemical
Resistance Medium

Resistance to
Moderate
Vibrations

Product List
Cross Section Insulation Thickness Outer Diameter Weight
(mm2) (mm) (mm) (kg/km)
300 2.4 26 3000

Other dimensions available on enquiry.

12 AirSolTM 1.Runway 1.1 RG : Runway Ground Lighting


Runway Ground Lighting Aircraft Powering

AirSolTM RG-CR4(UL2919-AMESB)
RS-422/485

Application
Runway airfiled light monitor

Construction
Conductor 24 AWG
Pair Multi
Shield(optional) Aluminum / polyester tape shield
Insulator Foamed PE
Insulation
Nom. 0.4mm
Thickness
Jacket Thickness Nom. 1.0mm

Product List
Jacket Diameter Impedance Max. Capacitance Weight
Pairs
(mm) (mm) ( ) (nF/100m) (kg/km)
2 PVC 7.8 110 4.5 66
3 PVC 8.2 110 4.5 75

Other dimensions available on enquiry.

1.1 RG : Runway Ground Lighting AirSolTM 1.Runway 13


Runway Ground Lighting Aircraft Powering

AirSolTM
Aircraft Powering Configuration

LDC LDC LDC LDC LDC LDC LDC LDC

A Terminal
MV Cable
B Terminal

LDC LDC LDC LDC LDC LDC LDC LDC

400Hz Power Cable

14 AirSolTM 1.Runway 1.2 RA : Runway Aircraft Powering


Runway Ground Lighting Aircraft Powering

AirSolTM 1.2 Runway Aircraft Powering


Primary Circuit Cable

Max. Cross Outer Diameter Bending


Material of Weight
Voltage Temperature Section Range Insulation Conductor Screen Radius Page
Conductor
( ) (mm2) (mm) [mm] (kg/km)

3x(1x50/20
44.1 132 2790 16
+8x1) ERP, PUR
Class 5
Polyolefin x Copper
or 2
3x(1x70/25 Copolymer
47.8 143 3560 17
400Hz +8x1)
Power 0.6/1 kV 90
Cable 4x(1x50
44.0 Tinned 176 2660 18
+4x1) ERP, PUR
Fine
Polyolefin x Copper
Copper,
4x(1x70 Copolymer Class 6
51.3 205 3590 19
+4x1)

A308

A308 AIRBUS

2X100 KVA

Fresh Water Waste Water PC Air 400Hz System


& Exhaust Pit System

1.2 RA : Runway Aircraft Powering AirSolTM 1.Runway 15


Runway Ground Lighting Aircraft Powering

AirSolTM RA-P600V-3C
400Hz Aircraft Power Cable

Application
Available for use in mobile and stationary application under operational
conditions of mechanical stress and climate for in-out door.
Suspended cables for passenger bridges etc.

Design Standard
IEC 60754-1, EN 50267-2-1, IEC 60754-2. EN 50267-2-2,
NES 02-713, NFC 20-454, IEC 60332-1, EN 50265,
EN 60811-2-1, UV Resistance

Construction Technical Data


Power Temperature -40 ~90
Conductor Tinned fine copper strands, Class 5 Bending Radius 3x(1x50/20+8x1) : Static 132mm, mobile 176mm
Bending Radius
Insulation Ethylene-Propylene-Rubber (EPR) 3x(1x70/25+8x1) : Static 143mm, mobile 191mm
Control cores Rated Voltage 0.6/1kV , 115/200V
Conductor Tinned fine copper strands acc.to
VDE 0295, IEC 60228 class 5
Insulation Polyolefin copolymer
Control cores and neutral conductor
Concentric stranding around the phase conductors.
Outer Sheath Abrasion resistant PUR

Product List
Cross Section Cross Section Outer Single Outer Weight
Conductor Diameter Approx
of Power Core of Control Cores (mm) (mm) (kg/km)
3x(1x50/20mm2) 3x(8x1mm2) 20.5 44.1 2790
2 2
3x(1x70/25mm ) 3x(8x1mm ) 22.2 47.8 3560

Other dimensions available on enquiry.

16 AirSolTM 1.Runway 1.2 RA : Runway Aircraft Powering


Runway Ground Lighting Aircraft Powering

AirSolTM RA-P600V-4C
400Hz Aircraft Power Cable

Application
Available for use in mobile and stationary application under operational
conditions of mechanical stress and climate for in-out door. mobile
400Hz generator units, suspended cables for passenger bridges etc.

Design Standard
IEC 60754-1, EN 50267-2-1, IEC 60754-2, EN 50267-2-2
NES 02-713, NFC 20-454, IEC 60332-1, EN 50265-1
EN 60811-2-1, UV Resistance

Construction Technical Data


Power Rated Voltage,
0.6/1kV , 115/200V
Conductor Tinned fine copper strands, Class 6 Nominal Voltage
Temperature -40 ~90
Insulation Ethylene-Propylene-Rubber (EPR)
Bending Radius 4x(1x50+4x1) : Static 176mm, mobile 220mm
Control
4x(1x70+4x1) : Static 205mm, mobile 256mm
Conductor 4x1mm2, tinned Copper strands, VDE 0295,
IEC60228, Class 6
Insulation Polyolefin copolymer double
Outer Sheath PUR

Product List
Cross section Cross Section Outer Single Outer Weight
Conductor Diameter Approx
of Power Core of Control Cores (mm) (mm) (kg/km)
4x(1x50mm2) 4x(4x1mm2) 18.2 44.0 2660
2
4x(1x70mm ) 4x(4x1mm2) 21.2 51.3 3590

Other dimensions available on enquiry.

1.2 RA : Runway Aircraft Powering AirSolTM 1.Runway 17


Runway Ground Lighting Aircraft Powering

AirSolTM RA-C
400Hz Aircraft Power Connector

Application
Aircraft 400Hz Powering cable connector

Technical Data
Rated Voltage 115/200V, 400Hz
Current Carrying Capacity 260A /90kV
Current Overhead 700A /3 min.
Test Voltage 4kV
Micro Switch max. 30V DC,100 mA

2 7 4
1. Connector front part
3 8 2. Replaceable silver plated contacts
3. Contact holder
4. Circlip
5. Fixed silver plated contacts
6. Connector half housing
7. Metal sleeve
8. Optional micro switch

18 AirSolTM 1.Runway 1.2 RA : Runway Aircraft Powering


Terminal
2.Airport

Airport Terminal
2
Airport Terminal
2.1 AT-C : Communication 2.2 AT-E : Emergency
LAN, Copper Fire alarm & CCTV System
AT-C-LC5M 5 AT-EM-P 40
AT-C-LC5e 6 AT-Em-A(AT-COFF-AMS) &AT-Em-CP 41
AT-C-LC5eM 7
AT-C-LC5eF 8 2.3 AT-P : Public Lighting
AT-C-LC5eSF 9 Power Cable
AT-C-LC6 10 AT-P-P3.6/3kV 43
AT-C-LC6F 11 AT-P-P3.6kV-A 44
AT-C-LC6SF 12 AT-P-P3.6kV-3C 45
AT-C-LC6A 13 AT-P-P3.6kV-A3C 46
AT-C-FSM 15
LAN, Copper Connector 2.4 AT-V : VFD
AT-C-LCCo 16
Power
LAN, Optical Fiber
AT-V-P0.6/1kV-E 47
AT-C-LO 2C 19
AT-V-P0.6/1kV-X 49
AT-C-LOL12C 20
AT-C-LOL 24C 21
AT-C-LOL 48C 22 2.5 AT-B : Busduct
AT-C-LOL 72C 23 Ex, Ez, Ef-Way
AT-C-LO 144C 24 AT-BE1000V 51
LAN, Optical Fiber Equipments Mini-Way
AT-BM1000V 53
AT-C-LOA 25
Lighting Busduct
RF Coaxial AT-BL440V 54
RF Coaxial, LHF
AT-C-RCL 28
AT-C-RCH 30
Radiating Coaxial, RFCX, RFCL
AT-C-RCX 32
AT-C-RCL 34
ECX
AT-C-ECX 36
Antena
AT-C-A 37
Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM 2.1 Airport Terminal Communication

LAN Network

Departure
LAN Copper Connector

Arrival

Baggage

Conference
Distributor Check in

Satellite
Receiver
Network

Display
LAN Copper Cable
Remote

Terminal Display Network (Ring Type)

Airport Integrated Communication Center

Control Tower
Substation

Boarding
Building

Data Center

Terminal

LAN Optical Fiber Cable

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 3


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM Airport Terminal Communication, LAN Copper


LAN, Copper Table

Conductor DC Operating Propagation


Number of Delay Skew Temperature Frequency Velocity
Category Resistance Impedance Insulation Conductor Jacket Page
Pairs
( /100m) ( ) (mm) (mm) (ns) ( ) (MHz) (%)

Cat3 HDPE PVC,


25~500 1~16 67 -
UTP 0.80mm 9~38mm

HDPE PVC, LSZH


2 67 -
0.90mm 4.0mm

Cat5 HDPE PVC, LSZH


4 67 -
UTP 0.90mm 4.8mm

25, 50, HDPE PVC, LSZH


67 5
75,100 0.95mm 12~28mm

Cat 24AWG, PVC, LSZH


9.38 100 15% HDPE Solid 45 -20~60
3~ 5E 4.8mm
0.9mm Copper
4 PVC 1~100 67 6
FEP
Cat5E (Plenum)
0.84mm
UTP 4.4mm

HDPE PVC, LSZH


25 67 7
0.95mm 13.0mm

Cat5E HDPE PVC, LSZH


4 67 8
F/UTP 1.02mm 6.1mm

Cat5E HDPE PVC, LSZH


4 67 9
SF/UTP 1.07mm 7.3mm

Conductor DC Delay Operating Propagation


Impedance Insulation Conductor Jacket Frequency
Category Resistance Skew Temperature Velocity Page
( /100m) ( ) (mm) (mm) (ns) ( ) (MHz) (%)
PVC, LSZH
5.9mm
Cat6 HDPE/FEP (Cross filler)
10
UTP 0.95mm PVC, LSZH
5.4mm
(None filler)
1~250
Cat6 HDPE PVC, LSZH
11
F/UTP 1.10mm 23AWG, 7.5mm
Cat
9.38 100±15% Solid 45 -20~60 67
6, 6A
Cat6 HDPE Copper PVC, LSZH
12
SF/UTP 1.12mm 8.0mm

HDPE PVC, LSZH


13
1.03mm 9.0mm
Cat6A
1~500
UTP
HDPE PVC(Plenum)
14
1.06mm 9.0mm

4 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC5M
Category 5 UTP Multipair

Application
Airport under system copper cable & backbone cabling
Voice communication cable, security system
4/16 Mbps token ring (IEEE 802.5)
10/100 BASE-T (IEEE 802.3)
155 Mbps ATM
100 Mbps TP-PMD
ISDN, ADSL

Construction

Type Degree Structure

Conductor : 24AWG
IEC-60754,
LSZH Insulation : HDPE
61034
Sheath : LSZH

Conductor : 24AWG
CMR UL-1666 Insulation : HDPE
Sheath : PVC (Flame resistance)

Conductor : 24AWG
UL-1685
CM Insulation : HDPE
IEC 332-3
Sheath : PVC (Flame resistance)

Technical Data
Frequency Attenuation Return Loss NEXT
(MHz) (dB/100m) (dB/100m) (dB/100m)
0.772 1.8 - 64.0
8 5.8 23 48.8
20 9.3 23 42.8
100 21.5 16 32.3

Product List
Pair / Conductor Diameter Out Diameter Weight
Type
(mm) (mm) (kg/km)

CM/CMR/LSZH 25 ~100 / 0.5 14~32 280~640

Other dimensions available on enquiry.

2.1 AT-C : Communication AirSolTMAirport Terminal 5


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC5e
Category 5E UTP 4 pair

Application
Horizontal distribution & backbone cabling
4/16 Mbps token ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL

Characteristic
UL, ETL, DELTA Verified for guaranteed performance
Supports fast ethernet, gigabit ethernet, 155 Mbps ATM, multimedia
All accepted design for global commercial network installation
Simplified structured cabling solution preserving long-term network investment
Electrical performances comply with TIA/EIA-568B.2
RoHS compliant

Part Numbers
Description Category 5E UTP Cable, 4-Pair

Flame Retardant Grade CMX CM CMR CMP LSZH


Part Numbers U05E004-X 1 U05E004-M 1 U05E004-R 1 U05E004-P 1 U05E004-L 1

Denotes color : WH=White, BL=Blue, GY=Gray ; # denotes packaging type : 1=reelex , 2=reelex , 3=reel in a box, 4=wooden reel

Technical Details
Item Unit PVC / LSZH Plenum

Conductor DC Resistance /100 m 9.38 9.38


Resistance Unbalance % 5 5
Mutual Capacitance nF/100 m 5.6 5.6
Capacitance Unbalance pF/100 m 330 330
Characteristic Impedance 100 15% 100 15%

Propagation Delay ns/100 m 538 100 MHz 538 100 MHz

Delay Skew ns 45 45

Nominal Velocity of Propagation % 67 68

Operating Temperature -20 ~ 60 / -4 ~140 -20 ~ 60 / -4 ~140

Storage Temperature -20 ~ 80 / -4 ~176 -20 ~ 80 / -4 ~176

Bending Radius 4 x Cable diameter 4 x Cable diameter

Packaging Type 305 m (1000ft) Reelex Reelex

Packaging Weight lb/kft (kg/km) 17 (25) 20 (30)

Conductor Diameter / Material 24 AWG, Solid copper 24 AWG, Solid copper

Insulation Diameter / Material inch (mm) 0.035 (0.90) , HDPE 0.033 (0.84) , FEP

Jacket Diameter / Material inch (mm) 0.189 (4.8) , PVC or LSZH (Low Smoke Zero Halogen) 0.173 (4.4) , LS-PVC (Plenum)

Approvals Safety UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / CMP - UL910 / LSZH - IEC61034, IEC60754/Plenum-UL910
Approvals Performance TIA/EIA-568-B.2 / ISO 11801“Performance specifications for 4-pair 100 category 5E / D cabling”

Other dimensions available on enquiry

6 AirSolTMAirport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC5eM
Category 5E UTP 25 Pair

Application
Backbone cabling
4/16 Mbps token ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100 Mbps TP-PMD
ISDN, ADSL

Characteristic
UL Verified for guaranteed performance
Supports fast ethernet, gigabit ethernet, 155 Mbps ATM, multimedia
All accepted design for global commercial network installation
Simplified structured cabling solution preserving long-term network investment
Electrical performances comply with TIA/EIA-568B.2
RoHS compliant

Part Numbers
Description Category 5E UTP Cable, 25-Pair

Flame Retardant Grade CMX CM CMR LSZH


Part Numbers U05E025-X 4 U05E025-M U05E025-R 4 U05E025-L 4

Denotes color : WH=White, BL=Blue, GY=Gray ; # denotes packaging type :1=reelex , 2=reelex , 3=reel in a box, 4=wooden reel

Technical Details
Item Unit PVC / LSZH
Conductor DC Resistance /100 m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100 m 5.6
Capacitance Unbalance pF/100 m 330
Characteristic Impedance 100 ~ 15%
Propagation Delay ns/100 m 538 100MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 70
Operating Temperature -20 ~ 60 / -4 ~140
Storage Temperature -20 ~ 80 / -4 ~176
Bending Radius 10 x Cable diameter
Packaging Type 305m (1000 ft) / 1000m Reel / drum
Packaging Weight lb/kft (kg/km) 124 (185)
Conductor Diameter / Material 24 AWG, solid copper
Insulation Diameter / Material inch (mm) 0.037 (0.095) , HDPE
Jacket Diameter / Material inch (mm) 0.511 (13.0) , PVC or LSZH (Low smoke zero halogen)
Approvals Safety UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance TIA/EIA-568-B.2 / ISO 11801 “Performance specifications for 4-pairs 100 category 5E / D cabling”

Other dimensions available on enquiry

2.1 AT-C : Communication AirSolTMAirport Terminal 7


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC5eF
Category 5E F/UTP 4 Pair

Application
Horizontal distribution & backbone cabling
4/16 Mbps Token ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL

Characteristic
Supports fast ethernet, gigabit ethernet, 155 Mbps ATM, multimedia
All accepted design for global commercial network installation
Simplified structured cabling solution preserving long-term network investment
Electrical performances comply with TIA/EIA-568B.2
Reel in a box is standard, so wire pulls through box opening for easy access
RoHS compliant

Part Numbers
Description Category 5E F/UTP Cable, 4-Pair

Flame Retardant Grade CMX CM CMR LSZH


Part Numbers F05E004-X 4 F05E004-M 4 F05E004-R 4 F05E004-L 4

Denotes color : WH=White, BL=Blue, GY=Gray ; # denotes packaging type : 1=reelex , 2=reelex , 3=reel in a box, 4=wooden reel

Technical Details
Item Unit PVC / LSZH

Conductor DC Resistance /100 m 9.38


Resistance Unbalance % 5
Mutual Capacitance nF/100 m 5.6
Capacitance Unbalance pF/100 m 330
Characteristic Impedance 100 ~ 15%
Propagation Delay ns/100 m 538 100MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
Operating Temperature -20 ~ 60 / -4 ~140
Storage Temperature -20 ~ 80 / -4 ~176
Bending Radius 4 x Cable diameter
Packaging Type 305m (1000 ft) / 1000m Reel in a box/reel
Packaging Weight lb/kft (kg/km) 30 (46)
Conductor Diameter / Material 24 AWG, solid copper
Insulation Diameter / Material inch (mm) 0.040 (1.02) , HDPE
Jacket Diameter / Material inch (mm) 0.240 (6.1) , PVC or LSZH (low smoke zero halogen)
Approvals Safety UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance TIA/EIA-568-B.2 / ISO 11801 "Performance specifications for 4-pair 100 category 5E / D cabling"

Other dimensions available on enquiry

8 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC5eSF
Category 5E SF/UTP Cable 4 Pair

Application
Horizontal distribution & backbone cabling
4/16 Mbps token ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL

Characteristic
Supports fast ethernet, gigabit ethernet, 155 Mbps ATM, multimedia
All accepted design for global commercial network installation
Simplified structured cabling solution preserving long-term network investment
Electrical performances comply with TIA/EIA-568B.2
Wooden reel is standard, so wire pulls through reel for easy access
RoHS compliant

Part Numbers
Description Category 5E SF/UTP Cable, 4-Pair

Flame Retardant Grade CMX CM CMR LSZH


Part Numbers SF05E004-X 4 SF05E004-M 4 SF05E004-R 4 SF05E004-L 4

Denotes color : WH=White, BL=Blue, GY=Gray ; # denotes packaging type : 1=reelex , 2=reelex , 3=reel in a box, 4=wooden reel

Technical Details
Item Unit PVC / LSZH

Conductor DC Resistance /100 m 9.38


Resistance Unbalance % 5
Mutual Capacitance nF/100 m 5.6
Capacitance Unbalance pF/100 m 330
Characteristic Impedance 100 ~ 15%
Propagation Delay ns/100 m 538 100MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
Operating Temperature -20 ~ 60 / -4 ~140
Storage Temperature -20 ~ 80 / -4 ~176
Bending Radius 4 x Cable diameter
Packaging Type 305 m (1000 ft) / 1000m Reel
Packaging Weight lb/kft (kg/km) 38 (57)
Conductor Diameter / Material 24 AWG, solid copper
Insulation Diameter / Material inch (mm) 0.042 (1.07) , HDPE
Jacket Diameter / Material inch (mm) 0.287 (7.3) , PVC or LSZH (low smoke zero halogen)
Approvals Safety UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance TIA/EIA-568-B.2 / ISO 11801 "Performance specifications for 4-pair 100 category 5E / D cabling"

Other dimensions available on enquiry

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 9


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC6
Category 6 UTP Cable 4 Pair

Application
Horizontal distribution & backbone cabling
4/16 Mbps token Rring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
ATM LAN 1.2G

Characteristic
UL, ETL, DELTA Verified for guaranteed performance
Capable of handling full broadband and baseband video signals
High flame retardant grade of the cable is protected propagation of fire (plenum cable)
Addition of balance requirements improves cable performance
Electrical performances comply with TIA/EIA-568B.2-1
Reelex & reel in a box is standard, so wire pulls through box opening for easy access
RoHS compliant

Part Numbers
Description Category 6 UTP Cable, 4-Pair

Flame Retardant Grade CMX CM CMR CMP LSZH


Part Numbers(Cross Filler) U006004-X 3 U006004-M 3 U006004-R 3 U006004-P 3 U006004-L 3
Part Numbers(Non Filler) U006004-X 3N U006004-M 3N U006004-R 3N U006004-P 3N U006004-L 3N

Technical Details
Item Unit PVC & LSZH / Plenum (Cross Filler) PVC & LSZH / Plenum (Non Filler)

Conductor DC Resistance /100 m 9.38 9.38


Resistance Unbalance % 5 5
Mutual Capacitance nF/100 m 5.6 5.6
Capacitance Unbalance pF/100 m 330 330
Characteristic Impedance 100 ~15% 100 ~15%
Propagation Delay ns/100 m 536 250MHz 536 250MHz
Delay Skew ns 45 45
Nominal Velocity of Propagation % 67 67
Operating Temperature -20~60 / -4~140 -20~60 / -4~140
Storage Temperature -20~80 / -4~176 -20~80 / -4~176
Bending Radius 4 x Cable diameter 4 x Cable diameter
Packaging Type 305 m (1000 ft) Reelex / reel in a box Reelex / reel in a box
Packaging Weight lb/kft (kg/km) 21 (32) / 27 (42) 19 (29) / 25 (38)
Conductor Diameter / Material 23~24 AWG, solid Copper 23~24 AWG, solid copper
Insulation Diameter / Material inch (mm) 0.037 (0.95) , HDPE / FEP 0.037 (0.95) , HDPE / FEP
Jacket Diameter / Material inch (mm) 0.232 (5.9) / 0.228(5.8) , PVC or LSZH 0.213 (5.4) / 0.200(5.1) , PVC or LSZH
Approvals Safety UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754 / plenum-UL 910
Approvals Performance TIA/EIA-568-B.2-1 / ISO 11801 “Performance specifications for 4-Pairs 100 category 6 / E cabling”

Other dimensions available on enquiry

10 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC6F
Category 6 F/UTP Cable 4 Pair

Application
Horizontal distribution & backbone cabling
4/16 Mbps token ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL
ATM LAN 1.2G

Characteristic
Capable of handling full broadband and baseband video signals
Addition of balance requirements improves cable performance
Electrical performances comply with TIA/EIA-568B.2-1
Wooden reel is standard, so wire pulls through reel for easy access
RoHS compliant

Part Numbers
Description Category 6 F/UTP Cable, 4-Pair

Flame Retardant Grade CMX CM CMR LSZH


Part Numbers F006004-X 4 F006004-M 4 F006004-R 4 F006004-L 4

Denotes color : WH=White, BL=Blue, GY=Gray ; # denotes packaging type : 1=reelex , 2=reelex , 3=reel in a box, 4=wooden reel

Technical Details
Item Unit PVC / LSZH

Conductor DC Resistance /100 m 9.38


Resistance Unbalance % 5
Mutual Capacitance nF/100 m 5.6
Capacitance Unbalance pF/100 m 330
Characteristic Impedance 100 ~15%
Propagation Delay ns/100 m 536 250MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
Operating Temperature -20~60 / -4~140
Storage Temperature -20~80 / -4~176
Bending Radius 4 x Cable diameter
Packaging Type 305 m (1000 ft) / 500 m Reel
Packaging Weight lb/kft (kg/km) 36 (54)
Conductor Diameter / Material 23 AWG, Solid copper
Insulation Diameter / Material inch (mm) 0.043 (1.10) , HDPE
Jacket Diameter / Material inch (mm) 0.295 (7.5) , PVC or LSZH (low smoke zero halogen)
Approvals Safety UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance TIA/EIA-568-B.2-1 / ISO 11801 “Performance specifications for 4-pairs 100 category 6 / E cabling”

Other dimensions available on enquiry

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 11


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC6SF
Category6 SF/UTP Cable 4 Pair

Application
Horizontal distribution & backbone cabling
4/16 Mbps token ring (IEEE 802.5)
10/100/1000 BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL

Characteristic
Supports fast ethernet, gigabit ethernet, 155 Mbps ATM, multimedia
All accepted design for global commercial network installation
Simplified structured cabling solution preserving long-term network investment
Electrical performances comply with TIA/EIA-568B.2-1
Wooden reel is standard, so wire pulls through reel for easy access
RoHS compliant

Part Numbers
Description Category 6 SF/UTP Cable, 4-Pair

Flame Retardant Grade CMX CM CMR LSZH


Part Numbers SF006004-X 4 SF006004-M 4 SF006004-R 4 SF006004-L 4

Denotes color : WH=white, BL=blue, GY=gray; # denotes packaging type : 1=reelex , 2=reelex , 3=reel in a box, 4=wooden reel

Technical Details
Item Unit PVC / LSZH

Conductor DC Resistance /100 m 9.38


Resistance Unbalance % 5
Mutual Capacitance nF/100 m 5.6
Capacitance Unbalance pF/100 m 330
Characteristic Impedance 100 ~15%
Propagation Delay ns/100 m 538 250MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
Operating Temperature -20~60 / -4~140
Storage Temperature -20~ 80 / -4 ~176
Bending Radius 4 x Cable diameter
Packaging Type 305 m (1000 ft) / 500 m Reel
Packaging Weight lb/kft (kg/km) 38 (57)
Conductor Diameter / Material 23 AWG, Solid copper
Insulation Diameter / Material inch (mm) 0.044 (1.12) , HDPE
Jacket Diameter / Material inch (mm) 0.315(8.0) PVC or LSZH (low smoke zero halogen)
Approvals Safety UL 444 / CMX - UL1581, IEC332-1 / CM - UL1685, IEC332-3 / CMR - UL1666 / LSZH - IEC61034, IEC60754
Approvals Performance TIA/EIA-568-B.2-1 / ISO 11801 "Performance specifications for 4-pair 100 category 6/E cabling"
Other dimensions available on enquiry

12 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC6A
Category 6A(10G) UTP Cable 4 Pair

Application
Horizontal Distribution & Backbone Cabling
4/16 Mbps Token Ring (IEEE 802.5)
10/100/1000/10G BASE-T (IEEE 802.3)
155 Mbps ATM
100Mbps TP-PMD
ISDN, ADSL

Characteristic
UL, ETL Verified for guaranteed performance
Capable of handling full broadband and baseband video signals
High flame retardant grade of the cable is protected propagation of fire (Plenum cable)
Addition of balance requirements improves cable performance
Every box packaging is included " Reel", so wire pulls through box opening for easy access
Alien Crosstalk and RoHS compliant

Part Numbers
Part Numbers
Description
Blue Grey White
Category 6A UTP Cable, 4Pair, CMX Rated U06A004-XBL4 U06A004-XGY4 U06A004-XWH4
Category 6A UTP Cable, 4Pair, CM Rated U06A004-MBL4 U06A004-MGY4 U06A004-MWH4
Category 6A UTP Cable, 4Pair, CMR Rated U06A004-RBL4 U06A004-RGY4 U06A004-RWH4
Category 6A UTP Cable, 4Pair, LSZH Rated U06A004-LBL4 U06A004-LGY4 U06A004-LWH4
* Part Number '#' Description : 1(Reelex ), 2(Reelex ), 3(Reel in a box), 4(Reel)
* Other colors abaicble on repuest

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 13


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LC6A
Category 6A(10G) UTP Cable 4 Pair

Performance Charateristics
Retum Loss(RL) : dB Insertion (Attenation) : dB Near End Cross Tak(NEXT) : dB PSNEXT: dB ELFEXT: dB PSELFEXT: dB PSANEXT: dB PSAELFEXT: dB
Frepuency
Standard Cat 6E Cat 6E Standard Cat 6E Cat 6E Standard Cat 6E Cat 6E Standard Cat 6E Cat 6E Standard Cat 6E Cat 6E Standard Cat 6E Cat 6E Standard Cat 6E Cat 6E Standard Cat 6E Cat 6E
(MHz) PVC LSZH PVC LSZH PVC LSZH PVC LSZH PVC LSZH PVC LSZH PVC LSZH PVC LSZH
(Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical) (Typical)
1 20.0 25.0 25.0 2.0 1.8 1.8 74.3 79.3 79.3 72.3 77.3 77.3 67.8 77.8 77.8 64.8 74.8 74.8 67.0 72.0 72.0 67.0 77.0 77.0
4 23.0 28.0 28.0 3.7 3.5 3.5 65.3 70.3 70.3 63.3 68.3 68.3 55.8 65.8 65.8 52.8 62.8 62.8 67.0 72.0 72.0 66.2 76.2 76.2
10 25.0 30.0 30.0 5.9 5.7 5.7 59.3 64.3 64.3 57.3 62.3 62.3 47.8 57.8 57.8 44.8 54.8 54.8 67.0 72.0 72.0 58.2 68.2 68.2
16 25.0 30.0 30.0 7.4 7.2 7.2 56.2 61.2 61.2 54.2 59.2 59.2 43.7 53.7 53.7 40.7 50.7 50.7 67.0 72.0 72.0 54.1 64.1 64.1
20 25.0 30.0 30.0 8.3 8.1 8.1 54.8 59.8 59.8 52.8 57.8 57.8 41.8 51.8 51.8 38.8 48.8 48.8 67.0 72.0 72.0 52.2 62.2 62.2
31.25 23.6 28.6 28.6 10.4 10.2 10.2 51.9 56.9 56.9 49.9 54.9 54.9 37.9 47.9 47.9 34.9 44.9 44.9 67.0 72.0 72.0 48.3 58.3 58.3
62.5 21.5 26.5 26.5 14.9 14.7 14.7 47.4 52.4 52.4 45.4 50.4 50.4 31.9 41.9 41.9 28.9 38.9 38.9 65.6 70.6 70.6 42.3 52.3 52.3
100 20.1 25.1 25.1 19.0 18.8 18.8 44.3 49.3 49.3 42.3 47.3 47.3 27.8 37.8 37.8 24.8 34.8 34.8 62.5 67.5 67.5 38.2 48.2 48.2
200 18.0 23.0 23.0 27.5 27.3 27.3 39.8 44.8 44.8 37.8 42.8 42.8 21.8 31.8 31.8 18.8 28.8 28.8 58.0 63.0 63.0 32.2 42.2 42.2
250 17.3 22.3 22.3 31.0 30.8 30.8 38.3 43.3 43.3 36.3 41.3 41.3 19.8 29.8 29.8 16.8 26.8 26.8 56.5 61.5 61.5 30.2 40.2 40.2
400 15.9 20.9 20.9 40.0 39.8 39.8 35.3 40.3 40.3 33.3 38.3 38.3 15.8 25.8 25.8 12.8 22.8 22.8 53.5 58.5 58.5 26.2 36.2 36.2
500 15.2 20.2 20.2 45.3 45.1 45.1 33.8 38.8 38.8 31.8 36.8 36.8 13.8 23.8 23.8 10.8 20.8 20.8 52.0 57.0 57.0 24.2 34.2 34.2
* Note. Expressed sweep-tested through the specified frequency ranges in dB per 100m (328ft) length.

Technical Details
Item Unit PVC/LSZH Plenum
Conductor DC Resistance Ohms/100m 9.38 9.38
Resistance Inbalance % 5 5
Mutual Capacitance nF/100m 5.6 5.6
Capacitance Unbalance pF/100m 330 330
Characiteristic Impedance 100 15% 100±15%
Propagation Delay ns/100m 536 500MHz 536 500MHz
Delay Skew ns 45 45
Nominal Velocity of Propagation % 67 69
Operating Temperature -20~60 -20~60
Storage Temperature -20~80 -20~80
Bending Radius 4 x Cable Diameter 4 x Cable Diameter
Packaging Type 305m(1000ft) Reel Reel
Weight Ibkft(kg/km) 40(60) 43(65)
Materials Conductors 23 AWG, Solid copper 23 AWG, Solid copper
Insulation in.(mm) 1.05 .HDPE 1.05 .FEP
Jacket in.(mm) 9.0 .PVC or LSZH(Low Smoke Zero Halogen) 9.0 .LS-PVC(Plenum Rated)
Approvals Safety UL-444
CMX-UL1581, IEC332-1
CM-UL1685, IEC332-3
CMR-UL1666
CMP-UL910
LSZH-IEC61034, IEC60754
Performance TIA/EIA-568-B.2-10

14 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-FSM
Multi Pair Copper Cable

Application
Duct installation, direct buried

Construction
Conductor Solid annealed copper 0.4, 0.5, 0.65 and 0.9
Insulation Dual expanded polyolefin with outer skin layer
Twisted Pair Individual insulated conductors are twisted into pairs
Core Assembly Cables having 25 pairs or fewer are assembled in
a single group. Cables having more than 25 pairs
are assembled in a units.
Core Wrap Non-hygroscopic tape shall be applied helically or
longitudinally
Filling Compound Water resistance filling
Shield Metallic foil shall consist of PE coated AL tape
Sheath Black color polyethylene

Product List
Conductor Size Average Mutual Capacitance Conductor Resistance NEXT [dB]
(mm) (nF/km) ( /km, Max) 772kHz
0.4 147
0.5 93.5 54.9
60
0.65 56.5 Within 25 pair (Group)
0.9 29

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 15


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LCCo
Category 5, 25Pair

Application
Horizontal distribution & backbone cabling
4/16 Mbps token ring (IEEE 802.5)
10/100/1000/10G BASE-T (IEEE 802.3)
155 Mbps ATM,100Mbps TP-PMDN, RoHS compliant
ATM LAN 1.2G,10Gbis ethernet

Construction (Shileld, Unshield 8Pin) Technical Data


Connector Type RJ45 and tool or too-less IDC type Current Rating 1.5 Amps
General Dimension HxWxL (23x16x34)mm2 DC Resistance 0.1 Max.
Accepts Solid Wire from 22 to 26 AWG Voltage 150 Vac Max.
Insertion Life 750 Mating Cycles
Test Standards Plug Retention Force 20 lbs (89N)
Category UL Certified, TIA/EIA-568 / ISO 11801 Temperature -40 ~ 68 (-40 ~ 154 )
Meet FCC CFR 47 Part 68 Humidity 10% ~ 90% RH
IDC Accept 22 ~ 26 AWG Solid Wire
Insulation Over 500M
Resistance

Product List
Freq PSN PS
Attenuation NEXT PL ELFEXT ACRF ACR PD
(Mhz) EXT
C5e C6 C6A C5e C6 C6A C5e C6 C6A C5e C6 C6A C6A C5e C6 C6
1 2.2 2.1 2.3 60 65 62 17 19 19 57.4 63.3 63.3 60.3 2.5 2.5 2.5
4 4.5 4 4.2 53.5 63 60.5 17 19 19 45.4 51.2 51.2 48.2 2.5 2.5 2.5
8 6.3 5.7 5.8 48.6 58.2 55.6 17 19 19 39.3 45.2 45.2 42.2 2.5 2.5 2.5
10 7.1 6.3 6.5 47 56.6 54 17 19 19 37.4 43.3 43.3 40.3 2.5 2.5 2.5
16 9.1 8 8.2 43.6 53.2 50.6 17 18 18 33.3 39.2 39.2 36.2 2.5 2.5 2.5
20 10.2 9 9.2 42 51.6 49 17 17.5 17.5 31.4 37.2 37.2 34.2 2.5 2.5 2.5
25 11.4 10.1 10.2 40.3 50 47.3 16 17 17 29.4 35.3 35.3 32.3 2.5 2.5 2.5
31.25 12.9 11.4 11.5 38.7 48.4 45.7 15.1 16.5 16.5 27.5 33.4 33.4 30.4 2.5 2.5 2.5
62.5 18.6 16.5 16.4 33.6 43.4 40.6 12.1 14 14 21.5 27.3 27.3 24.3 2.5 2.5 2.5
100 24 21.3 20.9 30.1 39.9 37.1 10 12 12 17.4 23.3 23.3 20.3 2.5 2.5 2.5
200 - 31.5 30.1 - 34.8 31.9 - 9 9 - 17.2 17.2 14.2 - 2.5 2.5
250 - 35.9 33.9 - 33.1 30.2 - 8 8 - 15.3 15.3 12.3 - 2.5 2.5
300 - - 37.4 - - 28.8 - - 7.2 - - 13.7 10.7 - - 2.5
500 - - 49.3 - - 23.2 - - 6 - - 9.3 6.3 - - 2.5

Other dimensions available on enquiry

16 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM Airport Terminal Communication, LAN Optical Fiber


LAN, Optical Fiber Table

Diameter of Nominal Nominal Tensile Min Bending Min. Bending Oper.


Fiber Fiber
Yarn Buffer Diameter Weight Load Term Radius Loaded Radius Installed Out Jacket Temperature
Type Count
(um) (mm) (kg/km) (N) (mm) (mm) ( )

- 600±50 1.6, 1.8 3, 4 65 32, 36 16, 18

- 900±50 2, 2.4, 2.9 4, 6.5, 9.5 65, 150 40, 48, 58 20, 24, 29

Duplex SM,
- - 600±50 1.6, 1.8 5.5, 7.0 100 32, 36 16, 18 LSZH -10~70
Cord MM

- 900±50 2, 2.4, 2.9 8, 12, 17 100, 250 40, 48, 58 20, 24, 29

- 900±50 2, 2.8 18, 28 130, 250 40, 56 20, 28

2, 4, 6, 8,
- 6.3 45 600 126 63
10, 12
Loose SM, LSZH
Glass -10~70
Tube MM PE
16, 18, 24 - 6.8 55 600 136 63

Break SM, 2, 4, 6, 8,
Aramid - - 7.5~10.5 300, 660 150~210 PVC -10~60
Out MM 10, 12

Diameter of Nominal Tensile Min Bending Min Bending Oper. Nominal


Fiber Fiber
Yarn Construction Buffer Diameter Load Term Radius Loaded Radius Installed Out Jacket Temperature weight
Type Count
(um) (mm) (N) (mm) (mm) ( ) (kg/km)

2,4,6,8,
Aramid 2.9~6.7 150, 300 58~134 29~67 0~60 10~40
12,16,24

Single 2,4,6,8, 25~95/


4.5~9.8 300, 660 90~196 45~98
Unit 12,16,24 20~90

Glass/ 6 Fiber SM* 180/


13.9 660 278 139
Aramid Subunits 24 160
SM, PVC,
Distribution 900
MM LSZH
12 Fiber 295/
48 18.3 660 366 183 -10~60
Subunits 275

Single 2,4,6,8, 4.5~9.8


300, 660 240~350 120~175 135~215
Unit 12,16,24 (Inner)
Aramid
6 Fiber SM* 13.9
660 432 216 330
Subunits 24 (Inner)

Micro SM, 2,4,6 PVC,


- - - 3.8 100 76 38 -10~60 15
Distribution MM 8,12 LSZH

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 17


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LO(IL)
Optical Fiber Cable Table

Coating Buffer jacket Nominal Min Bending Oper.


Fiber Fiber Max. Loading
Yarn Diameter Diameter Weight Radius Out Jacket Temperature Page
Type Count
(mm) (mm) (kg/km) (N) Installed (cm) ( )

Indoor SM, 900±50


Glass 2 245±10 18 - 4.3 PVC -20~75 19
Zip Cord MM (um)

12 245±10 3 272 2670 21.7 20

24 245±10 3 281 2670 24 21

Loose
LSZH
Tube SM Glass 48 245±10 3 281 2670 24 -45~70 22
PE

72 245±10 3 298 2670 25 23

144 245±10 3 513 2670 34 24

* Fiber type : SM, MM is Optional

18 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LO 2C
Indoor Zip Code

Application
Airport lower part system, private branch line, office branch line

Construction
Fiber
Type Indoor Zip cord, (SM)
Coating Diameter 245 ± 10 [ ], Coating Diameter [ ]
Buffer Jacket 900 ± 50 [ ]
Diameter
Cable
Technical Data
Configure Aramid strength member
between buffers and extruded cable jacket Temperature Operating (-20 ~75 ),
Jacket Material PVC Storage (-40 ~85 )
Outer Diameter 2.9mm x 5.9mm Min. Bending Radius Installation 4.3cm

Test Standards
Compression Strength 35 N/cm per TIA/EIA FOTP-41
Impact 2 Impacts at 0.74 N-m per TIA/
EIA - FOTP-25
Bending Radius EIA-TIA FOTP-104, 300roll
Flame Listing ETL or UL Type OFNP* & c(ETL or UL)
Type OFN-FT6 75
Flex 300 Cycles / EIA-TIA FOTP-104

Product List
Outer Diameter Weight
Mode
(mm) (kg/km)

S/M M/M 2.9x5.9 18kg/km

OFNP*: Nonconductive Optical fiber plenum cable. / Other dimensions available on enquiry.

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 19


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LOL 12C


Loose Tube 12 Core

Application
Airport lower part system, private branch line
Data communication, security & image
Airfield ground lighting system, office branch line

Construction
Fiber SM, Zero water peak
Coating Diameter 245 ± 10 [ ], Coating Diameter [ ]
Loose Tube
Buffer Jacket Thermoplastic
Buffer Jacket Diameter 3.0mm
Gel Filling Water-Blocking filler to prevent water
ingress
Cables
Configuration Water absorbent strength members are
Test Standards
applied between loose tube and outer jacket.
Steel corrugated armor is applied Flame Listing ETL1) or UL2) Type OFCR* &
between two low smoke zero halogen c(ETL or UL) OFC-FT4 75C
outer jacket. Compression Strength 220N/cm per TIA/EIA FOTP-41
Jacket Material Low smoke zero halogen PE Impact 2 Impacts at 5.88N-m per TIA/EIA FOTP-25
Out Diameter 14.5mm Flex 25 Cycles per EIA –TIA FOTP-104
ETL1) : Engineering Testing Laboratories
UL2) : Underwriters Laboratories
Technical Data OFCR* : Conductive Optical Fiber Riser Cable
DJSA**: Double jacket Single Armour
Temperature Operating (-45 ~75 ),
Storage (-50 ~75 ),
Installation ( -20 ~60 )
Min. Bending Radius Installation 21.7cm, & long term 14.5cm
Max. Loading Installation 2670N, & long term 890N

Product List
Coating Outer Buffer Loose
Jacket Weight
Mode Diameter Diameter Tube
(mm) (mm) (mm) (No.) (kg/km)
S/M 245±10 14.5 3.0 1 272

Other dimensions available on enquiry. / Fiber : 12C

20 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LOL 24C


Loose Tube 24 Core

Application
Airport lower part system, private branch line
Data communication, security & image
Airfield ground lighting system, office branch line

Construction
Fiber SM, Zero water peak
Coating Diameter 245 ± 10 [ ], Coating Diameter [ ]
Loose Tube
Buffer Jacket Thermoplastic
Buffer Jacket Diameter 3.0mm
Gel Filling Water-blocking filler to prevent water
ingress
Cables
Configuration 2 loose tubes and 3 fillers are SZ stranded
around a central strength member.
Test Standards
Water absorbent strength members and
ripcords are applied over cable core. Flame Listing ETL1) or UL2) Type OFCR* &
Steel corrugated armor is applied between c(ETL or UL) OFC-FT4 75C
two low smoke zero halogen jackets. Compression Strength 220N/cm per TIA/EIA FOTP-41
Jacket Material Low smoke zero halogen PE Impact 2 Impacts at 5.88N-m per TIA/EIA FOTP-25
Out Diameter 16mm Flex 25 Cycles per EIA –TIA FOTP-104
ETL1) : Engineering Testing Laboratories
UL2) : Underwriters Laboratories
Technical Data OFCR* : Conductive Optical Fiber Riser Cable
DJSA**: Double jacket Single Armour
Temperature Operating (-45 ~75 ),
Storage (-50 ~75 ),
Installation ( -20 ~60 )
Min. Bending Radius Installation 24cm, & long term 16cm
Max. Loading Installation 2670N, & long term 800N

Product List
Coating Outer Buffer Loose Weight
Mode Diameter Diameter Jacket Tube
(mm) (mm) (mm) (No.) (kg/km)
S/M 245±10 16 3.0 2 281

Other dimensions available on enquiry. / Fiber : 24C

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 21


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LOL 48C


Loose Tube 48 Core

Application
Airport lower part system, private branch line
Data communication, security & image
Airfield ground lighting system, office branch line

Construction
Fiber SM, Zero water peak
Coating Diameter 245 ± 10 [ ], Coating Diameter [ ]
Loose Tube
Buffer Jacket Thermoplastic
Buffer Jacket Diameter 3.0mm
Gel Filling Water-blocking filler to prevent water
ingress
Cables
Configuration 4 loose tubes and 1 filler tubes are SZ
stranded around a central strength
member. Water absorbent strength
Test Standards
members and ripcords are applied over
cable core. Steel corrugated armor is Flame Listing ETL1) or UL2) Type OFCR* &
applied between two low smoke zero c(ETL or UL) OFC-FT4 75C
halogen jackets. Compression Strength 220N/cm per TIA/EIA FOTP-41
Jacket Material Low smoke zero halogen PE Impact 2 Impacts at 5.88N-m per TIA/EIA FOTP-25
Out Diameter 16.0mm Flex 25 Cycles per EIA –TIA FOTP-104
ETL1) : Engineering Testing Laboratories
UL2) : Underwriters Laboratories
Technical Data OFCR* : Conductive Optical Fiber Riser Cable
Temperature Operating (-45 ~75 ), DJSA**: Double jacket Single Armour

Storage (-50 ~75 ),


Installation ( -20 ~60 )
Min. Bending Radius Installation 24cm, & long term 16cm
Max. Loading Installation 2670N, & long term 800N

Product List
Coating Outer Buffer Loose Weight
Mode Diameter Diameter Jacket Tube
(mm) (mm) (mm) (No.) (kg/km)
S/M 245±10 16 3.0 4 281

Other dimensions available on enquiry. / Fiber : 48C

22 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LOL 72C


Loose Tube 72 Core

Application
Airport lower part system, private branch line
Data communication, security & image
Airfield ground lighting system, office branch line

Construction
Fiber SM, Zero water peak
Coating Diameter 245 ± 10 [ ], Coating Diameter [ ]
Loose Tube
Buffer Jacket Thermoplastic
Buffer Jacket Diameter 3.0mm
Gel Filling Water-blocking filler to prevent water
ingress
Cables
Configuration 6 loose tubes are SZ stranded around a
central strength member. Water
absorbent strength members and
Test Standards
ripcords are applied over cable core.
Steel corrugated armor is applied between Flame Listing ETL1) or UL2) Type OFCR* &
two low smoke zero halogen jackets. c(ETL or UL) OFC-FT4 75C
Jacket Material Flame retardant, low smoke zero Compression Strength 220N/cm per TIA/EIA FOTP-41
halogen PE Impact 2 Impacts at 5.88N-m per TIA/EIA FOTP-25
Out Diameter 17.0mm Flex 25 Cycles per EIA –TIA FOTP-104
ETL1) : Engineering Testing Laboratories
UL2) : Underwriters Laboratories
Technical Data OFCR* : Conductive Optical Fiber Riser Cable
Temperature Operating (-45 ~75 ), DJSA**: Double jacket Single Armour

Storage (-50 ~75 ),


Installation ( -20 ~60 )
Min. Bending Radius Installation 25.5cm & long term 17cm
Max. Loading Installation 2670N & long term 800N

Product List
Coating Outer Buffer Loose
Mode Diaameter Diameter Jacket Tube Weight
(mm) (mm) (mm) (No.) (kg/km)
S/M 245±10 16 3.0 2 281

Other dimensions available on enquiry. / Fiber : 72C

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 23


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LO 144C


Loose Tube 144 Core

Application
Airport lower part system, private branch line
Data communication, security & image
Airfield ground lighting system, office branch line

Construction
Fiber SM, Zero water peak
Coating Diameter 245 ± 10 [ ], Coating Diameter [ ]
Loose Tube
Buffer Jacket Thermoplastic
Buffer Jacket Diameter 3.0mm
Gel Filling Water-Blocking filler to prevent water
ingress
Cables
Configuration 12 loose tubes are SZ stranded around a
central strength member. Water
absorbent strength members and
ripcords are applied over cable core.
Steel corrugated armor is applied between Test Standards
two low smoke zero halogen jackets. Flame Listing ETL1) or UL2) Type OFCR* &
Jacket Material Flame retardant, low smoke zero c(ETL or UL) OFC-FT4 75C
Halogen PE Compression Strength 220N/cm per TIA/EIA FOTP-41
Out Diameter 22.9mm Impact 2 Impacts at 5.88N-m per TIA/EIA FOTP-25
Flex 25 Cycles per EIA –TIA FOTP-104
ETL1) : Engineering Testing Laboratories
UL2) : Underwriters Laboratories
Technical Data OFCR* : Conductive Optical Fiber Riser Cable
DJSA**: Double jacket Single Armour
Temperature Operating (-45 ~75 )
Storage (-50 ~75 )
Installation ( -20 ~60 )
Min. Bending Radius Installation 34.3cm, & long term 22.9cm
Max. Loading Installation 2670N, & long term 800N

Product List
Coating Outer Buffer Loose Weight
Mode Diameter Diameter Jacket Tube
(mm) (mm) (mm) (No.) (kg/km)
S/M 245±10 22.9 3.0 12 513

Other dimensions available on enquiry. / Fiber : 144C

24 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-LOA
Optical Fiber Equipments

Accessory
Fiber Distribution Frame Connector & Jumper Cord Rack

Optical Termination Box Fiber Optic Splice Closure Fiber Optic Outlet

E-PON Solution
OLT ONU / ONT Router Switch

G-PON Solution
OLT ONU / ONT
OLT Optical Line Terminal

ONU Optical Network Unit

ONT Optical Network Terminal

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 25


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM Airport Terminal Communication, RF Coaxial


In Building Under Ground (Parking Lot)

Antenna

Coaxial Cable(FCX)

B1

B2

Radiating Cable
B3

Splitter

Antenna

Repeater

26 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM Airport Terminal Communication, RF Coaxial


RF Coaxial
Diameter of Diameter of Material of Diameter of Material of Diameter of Propagation
Material of Material of
Type Dielectric Inner Conductor Inner Outer Conductor Outer Jacket Velocity Page
Dielectric Jacket
(mm) (mm) Conductor (mm) Conductor (mm) (%)

12.5 5.0 CCA 14.2 16.4

23.0 9.4 SCT 25.2 28.2


LHF CCT 89 28
33.6 13.7 SCT 36.4 39.4

43.5 18.1 HCCT 46.5 50.0

12.0 / 12.5 4.8 / 5.0 CCA / CCA 13.8 / 14.2 16.0 / 16.4
CCT / CAT
22.1 / 23.0 9.0 / 9.4 SCT / SCT 24.9 / 25.2 27.9 / 28.2
Feeder
HFC FPE PE 88~89 30
Cable
32.5 13.1 SCT 36.0 39.0
CCT
42.5 17.2 HCCT 46.5 50.0

4.7 1.9 CCA 6.4 7.5


CCT
7.2 2.8 CCA 9.5 10.5

HFSC 88 -
8.9 3.6 CCA 12.2 13.6

CCT
23.0 9.4 HCCT 25.2 27.9

Diameter of Material Diameter of Inner Material of Diameter of Outer Material of Diameter of Propagation
Material of
Type Dielectric of Conductor Inner Conductor Outer Jacket Velocity Page
Jacket
(mm) Dielectric (mm) Conductor (mm) Conductor (mm) (%)

13.8 /
12.0 / 12.0 4.8 / 4.8 CCA / CCA 16.0 / 16.0
13.8
CCT / CAT
with Slot
25.2 / 28.2 /
23.0 / 23.0 9.4 / 9.4 SCT / SCT
25.2 28.2
RFCX 32
32.5 13.1 SCT 36.0 39.0
CCT
with slot
Radiating PE
42.5 FPE 17.2 HCCT 46.5 50.0 87~89
Cable (PVC)
CF with
23.3 9.0 SCT 23.7 Punched 29.7
Slot

RFCL 34.9 13.7 SCT 35.3 40.3 34


CF with
Punched
Slot
43.5 17.1 HCCT 45.5 50.6

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 27


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCL
LHF

1/2 7/8 1-1/4 1 - 5/8


LHF 12D / LHF-FR 12D LHF 22D / LHF-FR 22D LHF 33D / LHF-FR 33D LHF 42D / LHF-FR 42D

Construction
LHF 12D (1/2 ) LHF 22D (7/8 ) LHF 33D (1-1/4 ) LHF 42D (1-5/8 )
Inner Conductor Material / Construction Copper-Clad Smooth Smooth Helically Corrugated
Aluminum Wire Copper Tube Copper Tube Copper Tube
Diameter (mm) 5.0 9.4 13.7 18.1
Dielectric Material / Construction Foamed Foamed Foamed Foamed
Polyethylene Polyethylene Polyethylene Polyethylene
Diameter (mm) 12.5 23.0 33.6 43.5
Outer Conductor Material / Construction Annularly corrugated Annularly corrugated Annularly corrugated Annularly corrugated
Copper Tube Copper Tube Copper Tube Copper Tube
Diameter (mm) 14.2 25.2 36.4 46.5
Jacket Diameter Standard Jacket (mm) 16.4 28.2 39.4 50.0
Halogen-Free / 16.4 28.2 39.4 50.0
Flame-Retardant Jacket (mm)

Other dimensions available on enquiry.

Mechanical Characteristics
LHF 12D (1/2”) LHF 22D (7/8”) LHF 33D (1-1/4”) LHF 42D (1-5/8”)

Min. Bending Radius (mm) 125 250 380 500


Recommended Standard Jacket ( ) - 40 ~ +80 - 40 ~ +80 - 40 ~ +80 - 40 ~ +80
Operating Halogen-Free /
Temerature - 30 ~ +80 - 30 ~ +80 - 30 ~ +80 - 30 ~ +80
Halogen-Free / Flame-Retardant Jacket ( )
Nominal Weight Standard Jacket (kg/m) 0.23 0.47 0.84 1.07
Halogen-Free /
0.25 0.51 0.91 1.16
Flame-Retardant Jacket (kg/m)
Flat Plate Crush Resistance (kg/mm) 2.0 1.4 2.4 1.6
Max. Pulling Force (kg) 113 147 260 181

28 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCL
LHF
Electrical Characteristics
LHF 12D (1/2”) LHF 22D (7/8”) LHF 33D (1-1/4”) LHF 42D (1-5/8”)
DC Resistance Inner Conductor 1.6 (0.5) 1.5 (0.5) 1.1 (0.3) 1.4 (0.4)
/1,000m ( /1,000 ) Outer Conductor 2.3 (0.7) 1.9 (0.6) 1.0 (0.3) 0.6 (0.2)
Insulation Resistance (M km) 10,000 10,000 10,000 10,000
Dielectric Strength (for 1Min.) DC 4,000V DC 6,000V DC 9,000V DC 11,000V
Velocity of Propagation ( ) 89 89 89 89
Peak Power Rating (kW) 40 91 200 302
Max. Operating Frequency (GHz) 8.8 4.9 3.3 2.5
Characteristic Impedance ( ) 50 50 50 50
Return Loss (dB) 28 28 28 28

Attenuation (at 20 ) & Average Power Rating (at Ambient 40 , Inner Conductor 100 )
Frequency (MHz) LHF 12D (1/2”) LHF 22D (7/8”) LHF 33D (1-1/4”) LHF 42D (1-5/8”)
Attenuation 30 1.14 (0.35) 0.59 (0.18) 0.42 (0.13) 0.33 (0.10)
dB/100m 100 2.12 (0.65) 1.13 (0.34) 0.79 (0.24) 0.64 (0.20)
(dB/100ft) 150 2.60 (0.79) 1.40 (0.43) 0.98 (0.30) 0.80 (0.24)
450 4.58 (1.40) 2.52 (0.77) 1.77 (0.54) 1.48 (0.45)
824 6.31 (1.92) 3.51 (1.07) 2.49 (0.76) 2.11 (0.64)
894 6.55 (2.00) 3.67 (1.12) 2.61 (0.80) 2.20 (0.67)
960 6.84 (2.08) 3.82 (1.16) 2.72 (0.83) 2.31 (0.70)
1,000 7.00 (2.13) 3.92 (1.19) 2.79 (0.85) 2.38 (0.73)
1,700 9.32 (2.84) 5.29 (1.61) 3.84 (1.17) 3.28 (1.00)
1,800 9.61 (2.93) 5.47 (1.67) 3.97 (1.21) 3.40 (1.04)
2,000 10.19 (3.11) 5.81 (1.77) 4.25 (1.30) 3.63 (1.11)
2,400 11.10 (3.38) 6.46 (1.97) 4.73 (1.44) 4.05 (1.23)
3,000 12.96 (3.95) 7.37 (2.25) 5.43 (1.66) -
3,500 13.92 (4.24) 8.08 (2.46) - -
4,000 15.27 (4.65) 8.75 (2.67) - -
5,000 17.15 (5.23) 9.99 (3.04) - -
Average Power 30 6.10 13.58 21.30 35.22
Rating(kW) 100 3.32 7.36 11.50 18.16
150 2.71 5.98 9.32 14.53
450 1.55 3.38 5.23 7.85
824 1.13 2.46 3.78 5.51
894 1.09 2.36 3.61 5.28
960 1.05 2.27 3.48 5.03
1,000 1.03 2.22 3.40 4.88
1,700 0.78 1.67 2.53 3.54
1,800 0.76 1.62 3.61 3.42
2,000 0.71 1.53 2.31 3.20
2,400 0.65 1.38 2.09 2.85
3,000 0.58 1.22 1.84 -
3,500 0.53 1.12 - -
4,000 0.50 1.04 - -
5,000 0.44 0.92 - -
* Standard Conditions : V.S.W.R 1.0 : Ambient temperature 20
* Specifications subject to change without notice

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 29


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCH
HFC

1/2” 7/8” 1-1/4” 1-5/8”


HFC 12D / HFC-FR 12D HFC 22D / HFC-FR 22D HFC 33D / HFC-FR 33D HFC 42D / HFC-FR 42D

Construction
HFC 12D (1/2”) HFC 22D (7/8”) HFC 33D (1-1/4”) HFC 42D (1-5/8”)
Inner Conductor Material / Construction Copper-Clad Aluminum Wire Smooth Copper Tube Smooth Copper Tube Corrugated Copper Tube
Diameter (mm) 4.8 9.0 13.1 17.2
Dielectric Material / Construction Foamed Polyethylene Foamed Polyethylene Foamed Polyethylene Foamed Polyethylene
Diameter (mm) 12.0 22.1 32.5 42.5
Outer Conductor Material / Construction Annularly Corrugated Annularly Corrugated Annularly Corrugated Annularly Corrugated
Copper Tube Copper Tube Copper Tube Copper Tube
Diameter (mm) 13.8 24.9 36.0 46.5
Jacket Diameter Standard Jacket (mm) 16.0 27.9 39.0 50.0
Halogen-Free /
Flame-Retardant Jacket (mm) 16.0 27.9 39.0 50.0

Other dimensions available on enquiry.


Mechanical Characteristics
HFC 12D (1/2”) HFC 22D (7/8”) HFC 33D (1-1/4”) HFC 42D (1-5/8”)

Min. Bending Radius (mm) 125 250 380 500

Recommended Standard Jacket ( ) - 40 ~ +80 - 40 ~ +80 - 40 ~ +80 - 40 ~ +80


Operating Halogen-Free /
Temerature - 30 ~ +80 - 30 ~ +80 - 30 ~ +80 - 30 ~ +80
Halogen-Free / Flame-Retardant Jacket ( )
Standard Jacket (kg/m) 0.22 0.50 0.94 1.25
Nominal Weight
Halogen-Free /
0.26 0.56 1.00 1.34
Flame-Retardant Jacket (kg/m)
Flat Plate Crush Resistance (kg/mm) 2.0 1.4 2.4 2.7
Max. Pulling Force (kg) 113 147 260 250

30 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCH
HFC
Electrical Characteristics
HFC 12D (1/2”) HFC 22D (7/8”) HFC 33D (1-1/4”) HFC 42D (1-5/8”)
DC Resistance Inner Conductor 1.6 (0.5) 1.3 (0.4) 0.7 (0.2) 0.9 (0.3)
/1,000 ( /1,000 ) Outer Conductor 2.3 (0.7) 1.4 (0.4) 0.5 (0.2) 0.6 (0.2)
Insulation Resistance (M km) 10,000 10,000 10,000 10,000
Dielectric Strength (for 1Min.) DC 4,000V DC 6,000V DC 9,000V DC 11,000V
Velocity of Propagation ( ) 88 88 88 88
Peak Power Rating (kW) 40 91 205 315
Max. Operating Frequency (GHz) 8.8 5.0 3.3 2.5
Characteristic Impedance ( ) 50 50 50 50
Return Loss (dB) 28 28 28 28

Attenuation & Average Power Rating


Frequency (MHz) HFC 12D (1/2”) HFC 22D (7/8”) HFC 33D (1-1/4”) HFC 42D (1-5/8”)
Attenuation 30 1.17 (0.36) 0.64 (0.20) 0.44 (0.13) 0.36 (0.11)
dB/100m 100 2.17 (0.66) 1.19 (0.36) 0.83 (0.25) 0.67 (0.20)
(dB/100ft) 150 2.67 (0.81) 1.47 (0.45) 1.03 (0.31) 0.84 (0.26)
450 4.75 (1.45) 2.65 (0.81) 1.86 (0.57) 1.53 (0.47)
824 6.49 (1.98) 3.68 (1.12) 2.62 (0.80) 2.17 (0.66)
890 6.76 (2.06) 3.85 (1.17) 2.75 (0.84) 2.27 (0.69)
960 7.04 (2.15) 4.01 (1.22) 2.86 (0.87) 2.38 (0.73)
1,000 7.20 (2.19) 4.10 (1.25) 2.94 (0.90) 2.43 (0.74)
1,700 9.61 (2.93) 5.54 (1.69) 4.01 (1.22) 3.35 (1.02)
1,800 9.91 (3.02) 5.73 (1.75) 4.15 (1.26) 3.47 (1.06)
2,000 10.70 (3.26) 6.09 (1.86) 4.43 (1.35) 3.71 (1.13)
2,300 11.54 (3.52) 6.63 (2.02) 4.60 (1.40) 4.07 (1.24)
3,000 13.44 (4.10) 7.81 (2.38) 5.43 (1.66) -
3,400 14.44 (4.40) 8.52 (2.60) - -
4,000 15.81 (4.82) 9.42 (2.87) - -
5,000 17.77 (5.42) 10.84 (3.30) - -
Average Power 30 6.19 13.90 21.33 29.55
Rating(kW) 100 3.36 7.51 11.36 15.60
150 2.74 6.09 9.15 12.52
450 1.56 3.43 5.02 6.76
824 1.14 2.48 3.56 4.74
890 1.10 2.38 3.40 4.52
960 1.05 2.28 3.26 4.32
1,000 1.03 2.23 3.18 4.22
1,700 0.78 1.67 2.32 3.04
1,800 0.76 1.62 2.24 2.93
2,000 0.72 1.52 2.10 2.74
2,300 0.66 1.41 1.93 2.51
3,000 0.58 1.21 1.64 -
3,400 0.54 1.13 - -
4,000 0.49 1.03 - -
5,000 0.44 0.90 - -

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 31


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCX
RFCX

1/2” 7/8” 1-1/4” 1-5/8”


RFCX 12D / RFCX-FR 12D RFCX 22D/ RFCX-FR 22D RFCX 33D / RFCX-FR 33D RFCX 42D / RFCX-FR 42D

Construction
RFCX 12D (1/2”) RFCX 22D (7/8”) RFCX 33D (1-1/4”) RFCX 42D (1-5/8”)

Inner Conductor Material / Construction Copper-Clad Smooth Copper Smooth Copper Helically Corrugated
Aluminum Tube Tube Copper Tube

Diameter (mm) 4.8 9.4 13.1 17.2

Dielectric Material / Construction Foamed Polyethylene Foamed Polyethylene Foamed Polyethylene Foamed Polyethylene

Diameter (mm) 12.0 23.0 32.5 42.5

Outer Conductor Material / Annularly Corrugated Annularly Corrugated Annularly Corrugated Annularly Corrugated
Construction Copper Tube Copper Tube Copper Tube Copper Tube
with Milled Slots with Milled Slots with Milled Slots with Milled Slots

Diameter (mm) 13.8 25.2 36.0 46.5


Jacket Diameter Standard Jacket (mm) 16.0 28.2 39.0 50.0

Halogen-Free /
16.0 28.2 39.0 50.0
Flame-Retardant Jacket (mm)

Other dimensions available on enquiry.


Mechanical Characteristics
RFCX 12D (1/2”) RFCX 22D (7/8”) RFCX 33D (1-1/4”) RFCX 42D (1-5/8”)

Min. Bending Radius (mm) 125 250 380 500

Recommended Standard Jacket ( ) - 40 ~ +80 - 40 ~ +80 - 40 ~ +80 - 40 ~ +80

Operating Temerature Halogen-Free / - 30 ~ +80 - 30 ~ +80 - 30 ~ +80 - 30 ~ +80


Flame-Retardant Jacket ( )

Nominal Weight Standard Jacket (kg / m) 0.21 0.45 0.93 1.24

Halogen-Free /
0.24 0.50 1.00 1.34
Flame-Retardant Jacket (kg / m)

32 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCX
RFCX
Electrical Characteristics
RFCX 12D (1/2”) RFCX 22D (7/8”) RFCX 33D (1-1/4”) RFCX 42D (1-5/8”)

DC Resistance Inner Conductor 1.7 (0.5) 1.5 (0.5) 0.8 (0.2) 0.9 (0.3)

/1,000m ( /1,000ft) Outer Conductor 2.7 (0.8) 1.9 (0.6) 0.7 (0.4) 0.5 (0.2)

Insulation Resistance (M km) 10,000 10,000 10,000 10,000

Dielectric Strength (for 1Min.) DC 4,000V DC 6,000V DC 9,000V DC 11,000V

Velocity of Propagation (%) 88 89 88 87

Characteristic Impedance ( ) 50 50 50 50

Attenuation & Coupling Loss at 20


Frequency (MHz) RFCX 12D (1/2”) RFCX 22D (7/8”) RFCX 33D (1-1/4”) RFCX 42D (1-5/8”)
Attenuation 75 2.2 1.2 1.0 0.75
(dB/ m)
90 - 1.6 - -

150 3.1 1.6 1.3 0.95

320 - 2.6 - -

450 5.5 2.9 2.4 1.9

800 7.5 4.8 3.4 2.6

900 7.9 4.9 3.6 2.8

1,800 11.8 7.5 5.9 4.3

2,200 13.1 8.8 7.1 5.5

2,400 14.0 9.0 8.1 5.8

Coupling Loss (dB) 75 50/62 56/66 61/71 63/74

90 - 64/74 - -

150 59/71 65/74 70/77 72/81


320 - 69/79 - -

450 67/76 72/81 77/90 76/86

800 67/76 72/81 77/89 76/87

900 66/75 72/81 77/86 76/88

1,800 68/77 68/77 74/85 73/81

2,200 70/79 69/78 74/85 80/91

2,400 70/79 69/77 76/87 79/90

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 33


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCL
RFCL

7/8” 1-1/4” 1-5/8”


RFCL 22D / RFCL 33D / RFCL 42D /
RFCL-FR 22D RFCL-FR 33D RFCL-FR 42D

Construction
RFCL 22D (7/8”) RFCL 33D (1-1/4”) RFCL 42D (1-5/8”)

Inner Conductor Material / Construction Smooth copper tube Smooth copper tube Helically corrugated copper tube

Diameter (mm) 9.0 13.7 17.1

Dielectric Material / Construction Foamed polyethylene Foamed polyethylene Foamed polyethylene

Diameter (mm) 23.3 34.9 43.5

Outer Conductor Material / Construction Overlapped copper foil Overlapped copper foil Overlapped copper foil
with punched leaky slots with punched leaky slots with punched leaky slots

Diameter (mm) 23.7 35.3 45.5

Jacket Diameter Standard Jacket (mm) 29.7 40.3 50.6

Halogen-Free /
29.7 40.3 50.6
Flame-Retardant Jacket (mm)

Mechanical Characteristics
RFCL 22D (7/8”) RFCL 33D (1-1/4”) RFCL 42D (1-5/8”)

Min. Bending Radius (mm) 350 500 700


Recommended Standard Jacket ( ) - 40 ~ +80 - 40 ~ +80 - 40 ~ +80
Operating
Temperature Halogen-Free / - 30 ~ +80 - 30 ~ +80 - 30 ~ +80
Flame-Retardant Jacket ( )

Nominal Weight Standard Jacket (kg / m) 0.67 0.79 0.97

Halogen-Free /
0.72 0.95 1.16
Flame-Retardant Jacket (kg / m)

34 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-RCL
RFCL
Electrical Characteristics
RFCL 22D (7/8”) RFCL 33D (1-1/4”) RFCL 42D (1-5/8”)
DC Resistance Inner Conductor 1.5 (0.5) 1.5 (0.5) 1.5 (0.5)
/1,000m ( /1,000ft) Outer Conductor 2.0 (0.6) 2.5 (0.8) 2.0 (0.6)

Insulation Resistance (M km) 10,000 10,000 10,000

Dielectric Strength (for 1Min.) DC 6,000V DC 9,000V DC 11,000V

Velocity of Propagation ( ) 88 88 88

Characteristic Impedance ( ) 50 50 50

Attenuation & Coupling Loss at 20


RFCL 22D (7/8”) RFCL 33D (1~1/4”) RFCL 42D (1-5/8”)
Frequency 50%/95% 50%/95% 50%/95%
(MHz) Attenuation Attenuation Attenuation
Coupling Loss Coupling Loss Coupling Loss
(dB/100m) (dB) (dB/100m) (dB) (dB/100m) (dB)
RFCL 75 1.1 79/86 0.8 71/81 0.7 70/80
M-Type
150 1.5 77/83 1.1 76/85 0.9 70/80

450 3.0 60/65 2.1 64/70 1.6 62/67

800 4.0 63/73 3.3 64/72 2.6 65/70

900 4.3 65/75 3.6 64/70 2.8 65/70

RFCL 1,700 5.9 63/68 5.5 56/59 5.1 58/63


W-Type
1,900 6.2 64/69 5.9 62/67 5.2 56/61

2,100 6.5 64/69 6.3 64/69 5.7 58/63

2,300 7.0 65/70 6.7 60/65 6.4 60/65

2,400 7.3 65/70 7.3 60/65 7.0 60/65

RFCL 75 1.2 72/80 0.7 72/83 0.7 70/79

150 1.6 70/79 1.2 71/78 1.1 70/79

320 2.3 73/83 1.7 70/80 1.6 72/82

450 2.9 73/83 2.0 70/79 2.0 70/80


800 4.3 72/83 2.7 69/80 3.4 70/80

900 4.4 72/83 2.9 69/75 3.5 71/79


1,700 8.0 70/81 4.7 67/75 5.0 69/79

1,900 8.3 70/80 5.2 68/75 6.6 69/80

2,100 8.7 70/80 6.8 68/78 8.0 71/79

Other dimensions available on enquiry.

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 35


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-ECX
ECX

Application
Used in high-frequency circuits of TV set or electronic equipment

Design Standard
KS C 3610, LS cable standard

Construction
Inner-Conductor Solid or stranded plain annealed copper conductor
Outer-Conductor Copper braid shield
Insulation PE (Polyethylene)
Outer sheath PVC

Inner Conductor Outer Conductor


Insulation Sheath Approx. D.C Conductor Capacitance Attenuation
Product
Model Construction Diameter Thickness Shield Composition Carriers Thickness Overall Diameter Resistance(20 ) (1kHz) (10MHz)
(No / mm) (mm) (No / mm) (mm) (mm) ( / km) (F/ km) (dB/ km)

1.5D-2V 7/0.18 0.54 0.53 5/0.10 16 0.4 2.9 0.4 110 104 5 85
2.5D-2V 1/0.80 0.80 0.95 7/0.12 16 0.5 4.3 0.5 35.9 100 5 45
3D-2V 7/0.32 0.96 1.02 8/0.14 16 0.8 5.3 0.5 33.3 100 4 47
5D-2V 1/1.40 1.40 1.70 10/0.14 16 0.9 7.3 0.5 11.7 100 4 27
8D-2V 7/0.80 2.40 2.70 10/0.18 16 1.2 11.1 0.5 5.13 100 4 20
10D-2V 1/2.90 2.90 3.40 10/0.20 16 1.2 13.1 0.6 2.67 102 4 14
2.5C-2V 1/0.40 0.40 1.00 6/0.12 16 0.5 4.0 0.5 145 69 4 52
3C-2V 1/0.50 0.50 1.30 8/1.04 16 0.8 5.4 0.5 91.4 67 3 42
3C-2VS 7/0.18 0.54 1.28 8/0.14 16 0.8 5.4 0.5 100 67 3 48
5C-2V 1/0.80 0.80 2.05 10/0.14 16 0.9 7.4 0.5 35.9 67 3 27
7C-2V 7/0.40 1.20 3.05 10/0.18 16 1.1 10.4 0.5 20.7 67 3 22
10C-2V 7/0.50 1.50 3.95 10/0.20 16 1.3 13.0 0.6 13.1 67 3 18

Other dimensions available on enquiry.

36 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-C-A
Antenna

Application
Mobile communication

Design Standard
IEC60092-350, -351, -359, 60228, 60332-3-22, 60754-1, 60754-2, 61034

Construction
Omni On the celling
Single Band 1,710~2,500M (2dBi)
Dual Band 824~960M (2dBi) & 1,710~2,200M (3dBi) /
890~960M (2dBi) & 1,710~2,700M (2dBi)

Patch On the wall /pole


Dual Band 1,710~2,400 & 2,400~2,500M (7dBi) /
824~960M (8dBi) & 1,710~2,500M (6dBi) /
890~960M (6dBi) & 1,710~2,170M (9dBi)
806~960M (8dBi) & 1,710~2,500M (6dBi)

Yagi On the pole


GSM 890~960M (8dBi) & 1,710~2,390M (12dBi)

Speaker Omni On the pole


Dual Band 890~960M & 1,710~2,500M (2dBi)
Other dimensions available on enquiry.

2.1 AT-C : Communication AirSolTM 2.Airport Terminal 37


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM Airport Terminal, Emergency

Fire Alarm System

Power Supply

Audio & Emergency Power Cable

Ciren Horn

Fire Control Panel Smoke Detector

Pulse Station
PUSH
FULL

CCTV System

CCTV Power Cable

Patch
Panel
Video Camera
CUD
Power Supply

Bundle Patch Panel

Monitor

Pemete Keybord

Multiplexor

Recorder

38 AirSolTM 2.Airport Terminal 2.1 AT-C : Communication


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM 2.2 Airport Terminal, Emergency

Cross Out Current Max


Material of Weight
Voltage section Diameter Insulation Conductor Screen Rating Temperature Page
Conductor (kg/km)
(mm2) (mm) (A) ( )

2x1~4 7.4~11.8 15~36 87~247

Halogen
Emergency Copper
300/500V 3x1~4 7.8~13.2 free XL -20~70 o 13.5~32 70 102~295 40
Cable Class1, 2
compound

4x1~4 8.4~14.1 13.5~32 125~362

2.2 AT-E : Emergency AirSolTM 2.Airport Terminal 39


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-Em-P
Emergency Cable

Application
Fire detection & fire alarm systems for buildings, public address system,
emergency lighting.

Design Standard
BS 7629 Part 1
BS 5839-1 : 2002
Cat. Standard

Construction Technical Data


Conductor Bare copper : solid class 1 (1, 1.5, 2.5mm2) Rated Voltage 300/500 V
Stranded class 2 (4mm2) according to BS Frequency 50~60Hz
6360/IEC 60228 Temperature -20~70
Insulation Halogen free XL compound EMI
Earth Conductor Uninsulated protective conductor Bending Radius Max. 6xD
According to BS 6360 Same class & cross-sectional area as
insulated conductor
Screen Aluminium /polyester tape with optional
polyester tape
Outer Sheath Halogen free polyolefin

Product List
Cross section of Cables Outer Diameter Current Rating Voltage Drop (V/A x km) Weight Approx.
(mm2) (mm) (A) AC/DC 2 Cores Coaded AC 3 Cores Loaded (kg/km)
2x1 7.4~8.2 15.0 44 - 87
2x1.5 7.8~8.6 19.5 29 - 103
2x2.5 9.6~10.5 27.0 18 - 164
2x4 11.4~11.8 36.0 11 - 247
3x1 7.8~9.0 13.5 - 38 102
3x1.5 8.3~9.5 17.5 - 25 123
3x2.5 10.0~11.9 24.0 - 15 198
3x4 11.8~13.2 32.0 - 9.5 295
4x1 8.4~10.0 13.5 - 38 125
4x1.5 8.9~10.5 17.5 - 25 151
4x2.5 11.0~13.0 24.0 - 15 242
4x4 13.1~14.1 32.0 - 9.5 362

Other dimensions available on enquiry.

40 AirSolTM 2.Airport Terminal 2.2 AT-E : Emergency


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-Em-A (AT-COFF-AMS) & AT-Em-CP


Audio Signal & CCTV Power Cable

Application
Audio, control signal cable

Construction
Conductor Pair 1 AWG 22
Material Tinned copper
Technical Data
Insulation FEP
Outer Shield Outer shield material : tape aluminum Operating Voltage 300 Vrms
Foil-polyester tape, 100% Impedance 42
Outer Shield Temperature -70 ~200
22AWG, Tinned Copper
Drain Wire Capacitance 35pF /ft
Outer Jacket FEP (Fluorinated Ethylene Propylene) DC Resistance 15 /1000ft

CCTV Power Cable (F-CV, HFCO)

Application
CCTV powering & image transformer cable

Design Standard
KS C IEC 60502-1

Construction Technical Data


Conductor Class 2 Rated Voltage 0.6/1 kV
Insulation XLPE, Flame Resistance PVC Temperature -70 ~200
Sheath Flame Resistance PVC
Wires 1~4

CCTV Control Cable (F-CVV-S)

Design Standard
KS C IEC 60502-1

Construction Technical Data


Conductor Class 2 Voltage 0.6/1 kV
Insulation PVC Temperature -70 ~200
Shield Copper Braid
Sheath Flame Resistance PVC
Wires 2~30

2.2 AT-E : Emergency AirSolTM 2.Airport Terminal 41


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-Em-A (AT-COFF-AMS) & AT-Em-CP

Max. Cross Out Current


Material of Weight
Voltage Temperature section Diameter Insulation Conductor Screen Rating Page
Conductor (kg/km)
( ) (mm2) (mm) (A)
Bare
19.5~
6~25 XLPE Copper x 75~160 Copper 420~910 43
24.5
Class 2
Bare
3.6/6(7.2) 20.5~
90 6~25 XLPE Copper o - Copper 550~1050 44
Public kV 25.5
Class 2
Lighting
Conductor Bare
Cable
10~35 15.4~ XLPE Copper o 99~195 Copper 780~1600 45
19.2 Class 2
Bare
6/6(7.2) 33~
70 10~50 PVC Copper o 72~185 Copper 1450~3550 46
kV 46.5
Class 5

42 AirSolTM 2.Airport Terminal 2.3 AT-P : Public Lighting


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-P-P 3.6 / 6kV


Lighting Power Cable

Application
Low voltage public Lighting Cable, buried with a mechanical
protection (Laying to conduits)

Construction
Conductor Flexibility Brae copper class2, IEC60228
Semi Conductor Optional
Insulation XLPE
Semi conductor Optional
Concentric Conductor Bare copper wire spinning with waterproof tape
Insulation Sheath XLPE
Outer Sheath PVC

Technical Data
Rated Voltage 3.6/6 (7.2)kV
Frequency 50Hz
Temperature -15 ~60 (Max. 90 )
Mechanical Resistance Good
to Impacts
Bending Radius 20 x Outer diameter
10 x Outer diameter during laying installation

Product List
Cross Section of Core Max. Out Diameter D.C Permissible Current Rating Approx. Weight
(mm2) (mm) (A) (kg/km)

6 19.5 75 420
10 20.5 97 510
16 22.5 125 670
25 24.5 160 910

Other dimensions available on enquiry.

2.3 AT-P : Public Lighting AirSolTM 2.Airport Terminal 43


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-P-P 3.6kV-A


Lighting Power Cable

Application
Low voltage public Lighting Cable, buried with a mechanical
protection (Laying to conduits)

Construction
Conductor Flexibility Class 2
Central Conductor Bare Copper
Insulation XLPE
Screen Copper wires
Armour Type Steel tape
Outer Sheath PVC
Number of Cores 1 Cores

Technical Data
Rated Voltage 3.6/6 (7.2)kV
Frequency 50Hz
Temperature -15~60
Mechanical Resistance Very good
to Impacts
Bending Radius 20 x Outer diameter in during
Laying Installation 10 x Outer diameter

Product List
Cross Section of Core Max. Out Diameter D.C permissible Current Rating Approx. Weight
(mm2) (mm) (A) (kg/km)

6 20.5 75 550
10 21.5 97 650
16 23.0 125 820
25 25.5 160 1050

Other dimensions available on enquiry.

44 AirSolTM 2.Airport Terminal 2.3 AT-P : Public Lighting


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-P-P3.6kV-3C
Lighting Power Cable

Application
Low voltage public Lighting (road, motorway,
sports complex, ports, industrial).
Excellent longitudinal & radial resistance to water penetration
These cables could be buried directly without
complementary protection.

Construction Technical Data


Conductor Flexibility Brae copper class2, IEC60228 Rated Voltage 3.6/6 (7.2)kV
Semi Conductor - Frequency 50Hz
Insulation XLPE Temperature -15 ~60
Screen Semi conductor extruded Water Proof Excellent
Bare copper wire spinning Mechanical Resistance Good
to Impacts
Water Proof Tape -
Frequency 50Hz
Sheath XLPE
Bending Radius R= 6 x outer diameter
Assemble 3 Twisted single core
R=12 x outer diameter in during laying
installation

Product List
Cross Section of Core Diameter of the Bunchedcable Conductor Diameter D.C Current Rating Approx. Weight
(mm2) (mm) (mm) (A) (kg/km)

10 33.2 15.4 99 780


16 36.4 16.9 125 1000
25 40.0 18.2 165 1300
35 42.0 19.2 195 1600

Other dimensions available on enquiry.

2.3 AT-P : Public Lighting AirSolTM 2.Airport Terminal 45


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-P-P3.6kV-A3C
Lighting Power Cable

Application
Armoured cables are designed to be used to public lighting in road
infrastructure.
These cables can be buried directly without an additional mechanical protection.

Design Standard
National NF C 33-220

Construction Technical Data


Conductor Flexibility Brae copper class2, IEC60228 Rated Voltage 3.6/6 (7.2)kV
Insulation PVC Frequency 50Hz
Inner Sheath PVC forming filler (Polychloride vinyl) Temperature -15 ~60
Screen Semi conductive Tape & Copper tape Mechanical Resistance Good
Separate Sheath PVC to Impacts
Armour Steel tape Weather resistance Good
Outer Sheath PVC Chemical Resistance Good
Bending Radius R=16 x outer diameter in during laying
R= 8 x outer diameter in during laying
installation

Product List
Cross Section of Core Max. Outer Diameter of the D.C Permissible Current Rating Approx. Weight
(mm2) Bunched Cable (mm) (A) (kg/km)

10 33.0 72 1450
16 35.0 94 1750
25 39.5 120 2250
35 43.0 145 2700
50 46.5 185 3550

Other dimensions available on enquiry.

46 AirSolTM 2.Airport Terminal 2.3 AT-P : Public Lighting


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-V-P 0.6/1kV-E


VFD Cable(EPR Insulation)

Application
Ventilation system of airport terminal

Design Standard
IEC 60092-351, -353, -359, 60331, 60332-3 Cat.A, 60754-1, 61034, 61034-2, IEC 60502-1

Construction
Conductor Circular tinned stranded copper class 2
circular tinned flexible stranded copper class 5
Fire Proof Layer Mica / glass tape
Insulation
Halogen free EPR Technical Data
Cabling with Filler
Armour Copper wire braid + copper / polyester tape (100% Shield screen) Voltage 0.6 / 1 (1.2)kV
Outer Sheath Halogen free, SHF2 Temperature -25 ~ 90 (Operation)

Earth Wire Size


25, 35, 50, 70, 95, 120, 150, 185, 240, 300SQ

Product List
Cross Insulation Inner Sheath Sheath Aver. Thickness Diameter Cable Weight
Section Thickness Thickness Rigid Flex Rigid Flex Rigid Flex
(mm2) (mm) (mm) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
25 1.2 1.0 1.8 1.9 29.9 32.0 1820 1920
35 1.2 1.2 2.0 2.1 34.2 36.8 2435 2645
50 1.4 1.2 2.0 2.2 34.7 38.5 2910 3285
70 1.4 1.2 2.2 2.3 39.6 43.5 4025 4370
95 1.6 1.4 2.4 2.6 45.2 49.7 5470 5785
120 1.6 1.4 2.5 2.7 48.8 53.1 6415 6770
150 1.8 1.4 2.7 2.9 53.5 59.1 7865 8445
185 2.0 1.6 2.9 3.1 59.1 64.6 9415 9900
240 2.2 1.6 3.2 3.4 66.4 72.8 12130 12865
300 2.4 1.8 3.4 3.7 73.0 80.7 14530 15405

Other dimensions available on enquiry.

2.4 AT-V : VFD AirSolTM 2.Airport Terminal 47


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-V-P 0.6/1kV-E

Without Fire Proof Layer


Cross Insulation Inner Sheath Sheath Aver. Thickness Diameter Cable Weight
Section Thickness Thickness
Rigid Flex Rigid Flex Rigid Flex
(mm2) (mm) (mm) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
25 1.2 1.0 1.8 1.9 29.9 32.0 1775 1840
35 1.2 1.2 2.0 2.1 34.2 36.8 2375 2460
50 1.4 1.2 2.0 2.2 34.7 38.5 2860 3180
70 1.4 1.2 2.2 2.3 39.6 43.5 3950 4270
95 1.6 1.4 2.4 2.6 45.2 49.7 5390 5650
120 1.6 1.4 2.5 2.7 48.8 53.1 6330 6650
150 1.8 1.4 2.7 2.9 53.5 59.1 7780 8315
185 2.0 1.6 2.9 3.1 59.1 64.6 9315 9760
240 2.2 1.6 3.2 3.4 66.4 72.8 12005 12700
300 2.4 1.8 3.4 3.7 73.0 80.7 14395 15230

Other dimensions available on enquiry.

48 AirSolTM 2.Airport Terminal 2.4 AT-V : VFD


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-V-P 0.6/1kV-X


VFD Cable (XLPE Insulation)

Application
Ventilation system of airport terminal

Design Standard
IEC 60092-350, -351, -353, -359, 60228, 60332-3-22, 60754-1, 60754-2, 61034

Construction
Conductor Stranded bare copper class 2 (Round or sector shaped)
Insulation XLPE
Inner Cover Lapped or extruded
Shield / Armor Copper wire braid + copper-polyester tape Voltage 0.6 / 1kV
Outer Sheath SHF1 or SHF2 Operation Temp -30 ~ 80

Product List
Cross Section Max. Diameter Cable Weight Ampacity
No. of Core Conductor Shape
(mm2) (mm) (kg/km) (A)
3 Round 16 20.5 790 67
3 Round 25 25.0 1180 89
3 Round 35 27.5 1530 110
3 Round 50 30.5 2050 137
3 Round 70 32.0 2650 169
3 Sector Shaped 70 36.0 3070 169
3 Round 95 37.0 3440 205
3 Sector Shaped 95 40.5 4070 205
3 Round 120 42.0 4410 237
3 Sector Shaped 120 44.0 5090 237
3 Round 150 47.0 5420 273
3 Sector Shaped 150 52.0 6320 273

Other dimensions available on enquiry.

2.4 AT-V : VFD AirSolTM 2.Airport Terminal 49


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM 2.5 Airport Terminal, Busduct


Power Distribution

Cable

Distridutlon
Panel Board
Power Cable
Roof Top

Busduct

Distridutlon
Panel Board
Busduct
Roof Top

50 AirSolTM 2.Airport Terminal 2.5 AT-B : Busduct


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-BE 1000V


Ex, Ez, Ef-way

Application
Mass power line

Technical Data
Rated Current 630~7500A
Permissible Rated 24~200kA
Short-Time Current
Rated Voltage 1000 V
Line Components Length of components : up to 3m

Type of Busduct

3W+GE 4W+GE 4W(200%N)+GE

3W+50%E, 100%E 4W+50%E, 100%E 4W(200%N) + 50%E

Fittings

Horizontal Elbow Horizontal Offset Vertical Elbow Vertical Offset

2.5 AT-B : Busduct AirSolTM 2.Airport Terminal 51


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-BE 1000V

Fig. 1 Fig. 2

Fig. 3

Product List
Current Rating Dimension, t Dimension, A Dimension, W Weight , 3W Weight , 4W Weight ,4W+HE Weight ,4W+FE
Conductor Figure
(A) (mm) (mm) (mm) (kg/m) (kg/m) (kg/m) (kg/m)
630 41 107 7.58 8.43 8.79 9.15
800 62 128 8.83 10.09 10.63 11.17
1,000 86 152 10.92 12.14 12.89 13.64
Fig. 1
1,250 108 174 13.40 15.42 16.36 17.30
1,600 164 230 19.57 20.61 22.08 23.55
2,000 210 276 23.08 26.23 28.14 30.09
AL 6.35
2,500 (2)126 352 28.94 33.18 35.38 37.58
3,200 (2)164 428 34.86 42.44 45.29 48.14
Fig. 2
3,600 (2)184 468 38.31 45.40 48.59 51.78
4,000 (2)210 520 41.81 50.10 53.75 57.40
5,000 (3)184 686 57.74 68.43 73.22 78.01
Fig. 3
6,000 (3)210 764 64.03 73.61 81.51 89.41
Ex, Ez,
630 41 107 11.91 14.44 15.65 16.86
Ef-way
800 41 107 11.91 14.44 15.65 16.86
1,000 57 123 14.65 18.25 20.58 22.91
1,250 73 139 17.65 22.04 24.60 27.16 Fig. 1
1,600 108 174 26.74 31.00 36.47 41.94
2,000 145 211 31.69 37.39 44.76 52.13
CU 2,500 6.35 195 261 42.69 54.59 60.25 65.91
3,200 (2)108 316 50.16 63.60 69.87 76.14
3,600 (2)126 352 57.55 73.16 80.41 87.66
Fig. 2
4,000 (2)145 390 64.82 87.72 91.17 99.62
5,000 (2)195 490 85.26 109.14 121.08 133.02
6,000 (3)145 569 97.88 124.83 137.59 150.35
Fig. 3
7,500 (3)195 719 126.89 162.81 179.83 196.85

Other dimensions available on enquiry. / HE : Half Earth, FE : Full Earth

52 AirSolTM 2.Airport Terminal 2.5 AT-B : Busduct


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-BM1000V
Mini-Way

Application
Small power line

Technical Data
Rated Current 160~800A
Permissible Rated 10~40kA
Short-Time Current
Rated Voltage 1000 V
Line Components Length of components-up to 3m

Product List
Current Rating Dimension,T Dimension, W Dimension, A Dimension, H Weight, 4W Weight, Weight,
Conductor
(A) (mm) (mm) (mm) (mm) (kg/3m) 4W+HE (kg/3m) 4W+FE (kg/3m)
160 20 87 12 12.6 13.2
250 30 87 12.6 14 15.2
AL 400 50 107 21 22 23
630 50 127 28 29.7 31.4
800 70 152 33 35.3 37.6
6.35 165
160 20 87 13.5 15.5 17.5
250 30 87 17.6 19.6 21.6
CU 400 50 107 27 30.5 34
630 50 107 47 52 57
800 70 127 60 66 72

Other dimensions available on enquiry.

2.5 AT-B : Busduct AirSolTM 2.Airport Terminal 53


Terminal Communication Emergency Public Lighting VFD Busduct

AirSolTM AT-BL 440V


Lighting Busduct

Application
Wide range parking under ground

Technical Data
Rated Current 30~40A
Permissible Eated 4.4~9.6kA
Short-Time Current
Rated Voltage 440V
Line Components Length of components-up to 3m

Product List
Rated Service Current Rated short-time current Rated Voltage Length of Components
(A) (kA) (V) (m)
30 4.4 440
Up to 3m
40 9.6 440
Other dimensions available on enquiry.

54 AirSolTM 2.Airport Terminal 2.5 AT-B : Busduct


Handling System
3.Baggage

Baggage Handling System


3
PDU
Touch Panel Main PC

LV 400V
LV 24V
ASI BUS
Touch Panel
PROFlnet (Ethernet)
PROFIBUS

AC/DC AC/DC AC/DC

Conveyor Belt

Baggage Handling System


3.1 BH-C : Control
PROFIBUS
BH-C-P1(BH-C-PRFEU-AMSB) 4
BH-C-PW 5
Hybrid PROFIBUS
BH-C-HP 6
Proflnet
BH-C-PrPV75 7
BH-C-PrPU76 8
BH-C-PrPV64 9

3.2 BH-Co : Communication


LAN, Copper
BH-CLC 10

3.3 BH-P : Power


Low Voltage
BH-PL 11
Baggage Handling Control Communication Power
System

AirSolTM 3.1 Baggage Handling System, Control


Bus Cable Table

Diameter of Diameter of Diameter of


Wires Temperature Insulation Wires Jacket Conductor Shield Tensile Jacket Page
( ) (mm) (mm) (mm)

1x2x
0.64/0.67 PUR/PVC 100N 8~9 4
AWG22/19
PROFIBUS Bare Braid
-40~90 2.55
Cable Copper 70%/55%
1x2x
0.65 PE - 10.8 5
AWG22/1

Cross Section of Diameter of


Core Temperature Outer Insulation Jacket Conductor Diameter of Jacket Page
2
(mm ) ( ) (mm) (mm2) (mm)

Hybrid bus 1x2AWG24 Polyolefin


+ -40~80 9 PUR 1.5(Power) 9 6
Cable 4x1.5 POF

Diameter of Diameter of Diameter of


Wires Temperature Insulation Wires Jacket Conductor Shield Jacket Page
( ) (mm) (mm) (mm)

2x2x
-20~60 0.75 PVC 7
AWG22/7
85%
Profinet 19x Stranded
-40~80 1.5 0.76 PUR Tinned 6.5 8
Cable AWG22
Copper

2x2x
-20~60 0.64 PVC 90% 9
AWG22

3.1 BH-C : Control AirSolTM 3.Baggage Handling System 3


Baggage Handling Control Communication Power
System

AirSolTM BH-C-P1(BH-C-PRFEU-AMSB)
PROFIBUS

Application
Baggage handling system motor control cable

Construction Technical Data


Wire Bare Copper Wire 19 x 0.14 ( 0.67mm) Loop resistance 133 /km
Insulation Foamed of PE ( 2.56mm) Screen Resistance 15 /km
Core Wires, RD and GN twisted to a pair Insulation Resistance 16000 M /km
Overlapped Plastic tape Characteristic Impedance
Jacket PVC 5.4mm 3 - 20 MHz (150 + 15)
Overlapped Plastic tape 31.25 - 38.4 kHz (185 + 18.5)
Overlapped Aluminum-polyester foil 9.6 kHz (270 + 27)
Diameter of Shield Attenuation
Braiding of Tinned Nom.0.15mm 16 MHz 49 dB/km
Copper Wires 4 MHz 25 dB/km
Coverage Nom 80%, 6.3mm 38.4 kHz 4 dB/km
Jacket Polyurethane (PUR),wall thickness 9.6 kHz 3 dB/km
Approx. 0.8mm, (8.0 0.4)mm

Product List
Diameter of Core Diameter of Insulation Diameter of Jacket Weight Approx.
Wire
(mm) (mm) (mm) (kg/km)

1 x 2 x AWG22/19 0.67 2.56 8.0 ± 0.4 74

Other dimensions available on enquiry.

4 AirSolTM 3.Baggage Handling System 3.1 BH-C : Control


Baggage Handling Control Communication Power
System

AirSolTM BH-C-PW
PROFIBUS

Application
Motor control cable

Construction
Wire Bare copper wire ( 0.65mm)
Insulation Foamed of PE ( 2.55mm)
Core Wires, RD and GN twisted to a pair
Overlapped Plastic tape
Inner Jacket PVC 5.4mm
Overlapped Aluminum-polyester foil
Diameter of Shield
Braiding of Tinned Nom. 0.12mm
Copper Wires
Inner Jacket PVC violet (VT)
Wall Thickness Approx. 0.9mm, (8.0 0.4)mm
Jacket Polyethylene (PE) black (BK)
Wall Thickness Approx. 1.4mm, (10.8 0.5)mm

Product List
Diameter of Core Diameter of Insulation Diameter of Jacket Weight Approx.
Wire
(mm) (mm) (mm) (kg/km)

1x2xAWG22/1 0.65 2.55 10.8 ± 0.4 115

Other dimensions available on enquiry.

3.1 BH-C : Control AirSolTM 3.Baggage Handling System 5


Baggage Handling Control Communication Power
System

AirSolTM BH-C-HP
Hybrid PROFIBUS

Application
Used within machine tool or production equipment.
Polymer optic fibers provide maximum EMI resistance copper
cores transport power to controlled hydraulic and other actuators and sensors.

Design Standard
ISO 19258

Construction
POF + 4x1.5mm2 (PUR)
Conductor Bare copper stranded
Insulation Polyolefin Technical Data
Twisted Yes Cable Flexibility Flexible
Outer Sheath PUR Mechanical Resistance
Good
Number of Pairs 1 Pairs to Impacts
Number of Cores 6 Cores Temperature -40 ~80 (During Laying)
Conductor Cross Chemical Resistance Good
5mm2 (Power) Oil Resistance Yes
Section

Product List
Cross Section of Core Max. Out Diameter
Insulation Outer Sheath
(mm2) (mm)

1x2AWG24 + 4x1.5(mm2) 9 Polyolefin PUR

Other dimensions available on enquiry.

6 AirSolTM 3.Baggage Handling System 3.1 BH-C : Control


Baggage Handling Control Communication Power
System

AirSolTM BH-C-PrPV75
Profinet

Application
Baggage handling system communication between main controller & personal computer

Construction Technical Data


Wire Stranded tinned copper wire 7 X 0.25 0.75mm Limited Oil Resistance
Insulation Polyethylene (PE) 1.5mm Sunlight Resistant acc. to UL 1581 Sec. 1200
Core Filler as central element Permissible -40 ~ +70
Color White-Yellow-Blue-Orange (WH-YE-BU-OG) Temperature Range -20 ~ +60 (During Laying)
Plastic tape Overlapped -50 ~ +70 (Transport Temperature)
Inner Jacket PVC Min.Bending
Repeated 7x , single 3x
Shield Aluminated foil overlapped, Radius Allowed
tinned copper wires 0.13mm diameter 4.7 mm PVC Weight with
30.6 Kg/km
Shield Braiding Coverage approx. 85% Phthalate
Jacket PVC PVC Weight without
0.0 Kg/km
Phthalate
Wall Thickness 0.9 mm (6.5 0.2) mm
Weight Approx. 67Kg/km(45lb / 1000ft)

Near-end crosstalk attenuation

Frequency (MHz) 1 4 10 16 20 31.25 62.5 100

type. Value (dB-100m) 80 76 70 65 63 60 55 50

Attenuation
Frequency
1 4 10 16 20 31.25 62.5 100
(MHz)

type. Value (dB/100m) 2.1 4 6.3 8 9 11.4 16.5 21.3


(dB-100ft) (0.6) (1.2) (1.9) (2.4) (2.7) (3.5) (5.0) (6.5)

Product List
Diameter of wire Diameter of insulation Diameter of Jacket Loop Resistance Weight Approx
Wire
(mm) (mm) (mm) [ /km] (kg/km)

2x2xAWG22/7 0.75 1.5 6.5 ± 0.2 120 67

Other dimensions available on enquiry.

3.1 BH-C : Control AirSolTM 3.Baggage Handling System 7


Baggage Handling Control Communication Power
System

AirSolTM BH-C-PrPU76
Profinet

Application
Baggage handling system communication between
Main controller & personal computer

Construction
Wire Stranded tinned copper wire
Insulation Foamed polyethylene (PE) with skin 1.5 mm
Core Filler as central element
Color White-Yellow-Blue-Orange (WH-YE-BU-OG)
Screen Plastic tape, overlapped
Technical Data
Aluminum laminated foil, overlapped Electrical data at 20
Shield Tinned copper wires Loop Resistance 120 /km
Coverage approx. 85% Signal Run Time 4.7 ns/m
Screen Plastic tape, overlapped Insulation Resistance 500 M /km
Jacket Polyurethane (PUR) green (GN) Characteristic
100( 15)
impedance 1-100MHz
Wall Thickness Approx. 0.95mm (6.5 ±0.2) mm
Operating Voltage
Mechanical and Conductor/Screen material acc. to DIN EN 100 V
(Peak)
Thermal 13602 Cu-ETP-A.... -B Insulating material
Characteristics Test Voltage
acc. to DIN EN 50290-2-23 (VDE 0819), (wire/wire/screen = 700V
table 2/A (HD 624.3) rms 50Hz 1min.)

Frequency
1 4 10 16 20 31.25 62.5 100
(MHz)

ELFEXT (dB) 63.8 51.8 43.8 39.7 37.8 33.9 24 20

Attenuation max. (dB / 100m) 2.9 4.3 7.6 10 11.5 15.5 26.5 41
(dB / 100ft) (0.9) (1.3) (2.0) (2.7) (3.0) (4.1) (6.8) (10.4)

Product List
Diameter of Wire Diameter of Insulation Diameter of Jacket Resistance Weight Approx.
Wire
(mm) (mm) (mm) ( /km) (kg/km)

2x2x19xAWG22 0.76 1.5 6.5 ± 0.24 120 55

Other dimensions available on enquiry.

8 AirSolTM 3.Baggage Handling System 3.1 BH-C : Control


Baggage Handling Control Communication Power
System

AirSolTM BH-C-PrPV64
Profinet

Application
Baggage handling system communication
between main controller & personal computer

Construction
Wire Bare copper wire 0.64mm
Technical Data
Insulation Foamed polyethylene (PE) 1.5mm
Core Filler as central element Electrical data at 20
layer 4wires twisted Loop Resistance 115 /km
Color White-Yellow-Blue-Orange(WH-YE-BU-OG) Signal Run Time 5.3 ns/m
Screen Plastic tape, overlapped Insulation Resistance 500 M km
Inner Jacket PVC 3.9mm Characteristic
100( 15)
Impedance 1- 100MHz
Screen Aluminated foil overlapped
Surface Transfer
Shield braiding Tinned copper wires 0.13mm daimeter, 10V
Impedence 10 MHz
coverage approx. 90% 4.5mm
Test Voltage
Jacket PVC yellow-green RAL 6018 (GN) (Wire/Wire/Screen 2000V
Wall thickness approx. 0.9mm (6.5 ±0.2)mm Rms 50Hz 1min.)

Near-end Crosstalk Attenuation

Frequency
1 4 10 16 20 31.25 62.5 100
(MHz)

Type. Value (dB-100m) 80 75 70 65 63 60 55 50

Attenuation

Frequency
1 4 10 16 20 31.25 62.5 100
(MHz)

Type. Value (dB/100m) 1.6 3.2 5.2 6.9 7.8 10.5 15 19.5
(dB-100ft) (0.5) (1.0) (1.6) (2.1) (2.4) (3.2) (4.6) (5.9)

Product List
Diameter of Wire Diameter of Insulation Diameter of Jacket Loop Resistance Weight Approx.
Wire
(mm) (mm) (mm) ( /km) (kg/km)

2x2xAWG22 0.64 1.5 6.5 115 66

Other dimensions available on enquiry.

3.1 BH-C : Control AirSolTM 3.Baggage Handling System 9


Baggage Handling Control Communication Power
System

AirSolTM 3.2 Baggage Handling System, Communication


LAN, Copper Cable Table

Conductor DC Operating Propagation


Number of
Category Resistance Impedance Insulation Conductor Jacket Delay Skew Temperature Frequency Velocity
Pairs
( /100m) ( ) (mm) (mm) (ns) ( ) (MHz) (%)

Cat5e HDPE PVC,LSZH


24 AWG 1~100
SF/UTP 1.07mm 7.3mm
Cat 5e~6 4 9.38 100 15% 45 -20~60 67
Cat6 HDPE PVC,LSZH
23 AWG 1~250
SF/UTP 1.12mm 8.0mm

10 AirSolTM 3.Baggage Handling System 3.2 BH-Co : Communication


Baggage Handling Control Communication Power
System

AirSolTM 3.3 Baggage Handling System, Power


Power Cable Table

Cross section Insulation Outer Insulation


Conductor Material of
Voltage Insulation Temperature of Conductor Thickness Diameter Resistance Weight
Class Conductor
(V) ( ) (mm2) (mm) (mm) (M , km) (kg/km)

0.01
1.5~16 1, 2 0.7 ~ 1.0 2.6 ~ 7.8 20~170
~ 0.005

0.005
90 25~70 1.2 ~ 1.4 8.1 ~ 14.6 260~670
~ 0.0035
2
PVC 0.0035
95~400 1.6 ~ 2.6 14.1 ~ 33.2 920~3730
Low (Moisture, ~ 0.0028
Voltage 450/750 Heat / Cu
Cable Abrasion 0.010
1.5~6 0.7 , 0.8 2.8 ~ 5.3 30~80
Resistance) ~ 0.006

0.0056
70 10~50 5 1.0 ~ 1.4 5.7 ~ 11.7 130~500
~ 0.0037

0.0032
70~240 1.4 ~ 2.2 13.2 ~ 28.4 700~2240
~ 0.0028

3.3 BH-P : Power AirSolTM 3.Baggage Handling System 11


4.Power Infra

4
Power Infra
Power Infra
4.1 PI-P : Power
High Voltage
PI-P-HX 154kV 4
PI-P-H 132kV 5
Medium Voltage
PI-P-M22.9kV 6
PI-P-M36/66kV 7

4.2 PI-J : Joints


PI-P-JE 8
PI-P-JM 9
PI-P-JL 10
AirSolTM 4.1 Power Infra
Power Cable Table

Conductor Diameter of Diameter of


Voltage Material of
Insulation Size Conductor Sheath Metal Sheath Shield Cable Page
Conductor
(kV) (mm2) (mm) (mm)

Calendered Lead
DC 250 800 - - 110 Solid Copper -
Paper Tape Cu-Te
PE, PVC
Corrugated
154~400 Kraft Paper 1,200~2,000 47.2~58.8 - 119~145 -
High Al, Lead
Stranded
Voltage
Wire, Copper
Cable Extruded
66~500 630~2,000 30.2~54.3 - - Corrugated AL, 5
XLPE
Lead

36/66 - 240~2,000 - PE - Lead 62~104 Copper 7

Out
Voltage Number of Cross Section Material of Weight
Insulation Sheath Shield Diameter Page
Cores Conductor
(kV) (mm2) (mm) (kg/km)
25.8 / 51.6 800 / 2690
1/3 25 ~185 ~ ~ -
38.9 / 79.2 Tin/ 2,650 / 8,880
Enhanced Copper
8.7/15 XLPE Annealed
PVC Tape
Copper
1 240, 300 41.5, 44.6 3,340, 4,040 -

Medium 41/78
Voltage 1/3 50~400 ~ Annealed - -
PVC, PE Wire 59/121
Cable XLPE Copper,
12/20 Halogen Corrugated
TR-XLPE AL Strand
Free AL
1 500~1,000 63~75 wires - -

Anneled Annealed 1,050


22.9 1 38~600 PVC 34~61 ~ 6
Copper Wire Copper 10,050

4.1 PI-P : Power Cable AirSolTM 4.Power Infra 3


AirSolTM PI-P-HX 154kV
HV Power Cable 154kV

Construction
Conductor Copper
Insulation XLPE
Shield Copper Wire
Sheath PE (PVC)

Continuous Current Ratings for Single Circuit (A)


Cross Section In Air
Direct Buried Pipe Duct
(mm2) Trefoil Flat (S=2D)
300 591 553 684 765
400 673 629 789 887
500 766 713 907 1027
630 871 829 1043 1193
800 977 928 1181 1367
1000 1143 1081 1415 1639
1200 1232 1208 1535 1790
1600 1404 1382 1765 2100
2000 1554 1523 1973 2384
2500 1636 1603 2077 2510

Constructional Data (Nominal Values)


Thickness of Thickness of Diameter and Thickness of Outer Max. DC
Cross Construction Diameter Conductor Insulation Insulation Number of Outer Diameter Weight of Conductor Capacitance
Section Shape Screen Approx. Thickness Screen Approx. Copper Wires Sheath of Cable Cable Resistance at 20
(mm2) (mm) (mm) (mm) (mm) (mm No) (mm) (mm) (mm) ( / km) ( / km)

300 20.4 1.5 17 1.3 1.5 x 80 4.5 72 6.3 0.0601 0.21

400 23.2 1.5 17 1.3 1.5 x 80 4.5 75 7.2 0.0470 0.23


Compact
500 Round 26.3 1.5 17 1.3 1.5 x 80 4.5 79 8.6 0.0366 0.25
Stranded
630 30.2 1.5 17 1.3 1.5 x 80 4.5 83 10.1 0.0283 0.28

800 34.0 1.5 17 1.3 1.5 x 80 4.5 87 12.0 0.0221 0.30

1000 38.7 1.5 17 1.3 1.5 x 80 4.5 92 14.4 0.0176 0.33

1200 41.8 1.5 17 1.3 1.5 x 80 4.5 98 16.7 0.0151 0.36


Segment
1600 Tranded 48.1 1.5 17 1.3 1.5 x 80 4.5 105 20.9 0.0113 0.40
(Miliken)
2000 54.3 1.5 17 1.3 1.5 x 80 4.5 112 25.4 0.0090 0.44

2500 63.0 1.5 17 1.3 1.5 x 80 4.5 118 31.1 0.0072 0.34

Other dimensions available on enquiry.

4 AirSolTM 4.Power Infra 4.1 PI-P : Power Cable


AirSolTM PI-P-H 132kV
HV Power Cable 132kV

Application
Connect a power plant to a substation
Connect a substation to a substation

Construction
Conductor Concentric, compacted circular (less than
800mm2) and segmental compacted circular
(Over 1000mm2)
Insulation Extruded cross-linked polyethylene

Metallic Shield Screen Copper wire shield


Sheath Lead sheath and corrugated
aluminum sheath are available. Technical Data
Outer Sheath PE or PVC Voltage 132kV

132kV Aluminum Sheath Type


Cross Section Conductor Diameter Capacitance Current Rating
(mm2) (mm) ( /km) (A)

630 30.2 0.21 856


800 34.0 0.23 956
1000 38.7 0.25 1103
1200 41.8 0.27 1185
1600 48.3 0.30 1333
2000 54.3 0.32 1452
Directly Buried Type
Other dimensions available on enquiry.
Refer to LS EHV Cable System Catalogue

4.1 PI-P : Power Cable AirSolTM 4.Power Infra 5


AirSolTM PI-P-M 22.9kV
MV Power Cable 22.9kV

Application
Power cable used for industrial and commercial multiple grounding power and distribution circuits

Design Standard
ESB or LS

Construction
Conductor Circular compacted stranded filled with water blocking material plain annealed copper
Insulation 90 , Extruded cross-linked polyethylene with semi-conductive inner and outer screen
Neutral Conductor Annealed copper wires with water-blocking tapes
Sheath Black PVC / Black halogen free flame retardant polyolefin

Certification
KEPCO 60mm2, 200mm2, 325mm2, 600mm2

Constructional Data (Nominal Values)


Conductor Insulation Sheath Apporx. Conductor Test Approx.
Nominal Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
38 7.3 34 0.481 52 1050
60 9.3 36 0.305 52 1760
100 12.0 40 0.183 52 2430
150 14.7 43 0.122 52 3150
Compacted
200 17.0 3.0 45 0.0915 52 3980
Circular 6.6
250 19.0 48 0.0739 52 4700
(Waterproof)
325 21.7 51 0.0568 52 5750
400 24.1 54 0.0462 52 6850
500 26.9 57 0.0369 52 8240
600 29.5 4.0 61 0.0308 52 10050

Electric Constant (Reference)


Cross Section AC Conductor Resistance(R) Reactance(X) Impedance(Z)
(mm2) ( / km) ( / km) ( / km)
38 0.614 0.188 0.642
60 0.390 0.174 0.472
100 0.234 0.162 0.285
150 0.157 0.152 0.219
200 0.119 0.147 0.189
250 0.0963 0.141 0.171
325 0.0753 0.136 0.155
400 0.0624 0.132 0.146
500 0.0515 0.128 0.138
600 0.0444 0.127 0.135

Other dimensions available on enquiry.

6 AirSolTM 4.Power Infra 4.1 PI-P : Power Cable


AirSolTM PI-P-M 36/66kV
HV Power Cable 36/66kV with Lead Sheath

Construction
Conductor Copper
Insulation XLPE
Sheath Lead
Sheath PE (PVC)

Continuous Current Ratings for Single Circuit (A)


Cross Section In Air
Direct Buried Pipe Duct
(mm2) Trefoil Flat (S=2D)

240 535 525 621 706


300 606 567 710 810
400 691 646 822 942
500 787 733 951 1098
630 898 833 1096 1274
800 1008 958 1243 1462
1000 1184 1121 1505 1759
1200 1282 1208 1648 1938
1600 1469 1434 1906 2282
2000 1626 1585 2130 2597

Constructional Data (Nominal Values)


Conductor Thickness of Insulation Thickness of Thickness of Thickness of Outer Weight Max. DC
Conductor Screen Thickness Insulation Screen Lead Outer Diameter of Conductor Capacitance
Cross Section Diameter Sheath Sheath of Cable Cable Resistance at 20
Shape Approx. Approx.
(mm ) 2
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (kg / m) ( / km) ( / km)
240 18.1 1.0 11.0 1.0 2.1 3.5 62 8.1 0.0754 0.20
300 20.4 1.0 11.0 1.0 2.2 3.5 64 9.1 0.0601 0.21
Compact
400 23.2 1.0 11.0 1.0 2.3 3.5 67 10.5 0.0470 0.23
Round
500 26.3 1.0 11.0 1.0 2.4 4.0 72 12.5 0.0366 0.25
Stranded
630 30.2 1.0 11.0 1.0 2.4 4.0 76 14.2 0.0283 0.28
800 34.0 1.0 11.0 1.0 2.6 4.0 80 16.9 0.0221 0.30
1000 38.7 1.0 11.0 1.0 2.7 4.0 85 19.9 0.0176 0.33
Segment
1200 41.8 1.0 11.0 1.0 2.8 4.5 91 23.0 0.0151 0.36
Stranded
1600 48.1 1.0 11.0 1.0 3.0 4.5 97 28.0 0.0113 0.40
(Miliken)
2000 54.3 1.0 11.0 1.0 3.2 4.5 104 33.4 0.0090 0.44

Other dimensions available on enquiry.

4.1 PI-P : Power Cable AirSolTM 4.Power Infra 7


AirSolTM PI-P-JE
EHV Cable Joints & Terminations

Pr-Molded Joints
72.5kV up to 420kV
Conductor ~2500SQmm2
Pre-molded one piece type design
Silicone-based rubber sleeve
Casing / Coffin-box

Transition Joints
72.5kV up to 420kV
Conductor ~2500SQmm2
XLPE-OF Cable transition
Prefabricated type design

Outdoor(Dry type) Terminations


72.5kV up 123kV
Conductor ~2000SQmm2
Dry type design
Silicone-based one piece stress relief cone and bushing

Oil Immersed Transformer Terminations


72.5kV up to 420kV
Conductor ~2500SQmm2
Dry type design
EPR-based stress relief cone
Epoxy housing

Outdoor(Slip-on type) Terminations


72.5kV up to 420kV
Conductor ~2500SQmm2
Pre-molded slip-on type design
Silicone - based stress relief cone
Porcelain or polymer bushing

SF6 Immersed Sealing Ends


72.5kV up to 420kV
Conductor ~2500SQmm2
Dry type design
EPR-based stress relief cone
Epoxy housing

All of the accessories for EHV cable could be supplied with optical fiber joint and PD sensor depending on optional requirements.

8 AirSolTM 4.Power Infra 4.2 PI-J :Joint


AirSolTM PI-P-JM
MV Cable Joints & Terminations

Product
Medium voltage joints and terminations for polymeric insulated cables up to 36kV
Cross section : 25mm2 ~ 600mm2
Indoor and outdoor
Heat shrinkable and cold shrinkable type
Mechanical and compression connector

Structure
Bushing (Type C)
Mechanical Connector
Conductive EPDM Insert
EPDM Insulation Layer
Conductive EPDM Jacket
Conductive Rubber Cap
Basic Insulating Plug
Conductor Connector
Cable Reducer
Earthing Lead

Mechanical joint closures


Joint 3.3kV (2 35, AL), Joint 12/20kV

MV Cold shrink joint closures


Joint 6.6/11kV, Joint 12/20kV, Joint 19/33kV

MV Heat-shrink Terminations
No sheds for indoor applications up to 42kV
Unique zinc oxide stress control system
Simple to installation

MV Cold-shrink terminations
11kV (Single or three core)
11kV Copper wire, copper tape screen cable
11kV Outdoor/Indoor
33kV Polymeric insulated copper wire screen cables.
33kV Copper wire tape screen
33kV Indoor/outdoor single/three core 35 ~ 630mm2
Up to 25/46kV

4.2 PI-J :Joint AirSolTM 4.Power Infra 9


AirSolTM PI-P-JL
LV Cable Joints

Joints for plastic insulated multi-core control cables


Heat shrinkable joints for control cables
Cross Section : 4 ~ 75 X 1.5mm2 ~ 2.5mm2

Heat-shrink type
Voltage : 0.6/1kV
Type : Plastic and paper insulated
Core : 3 core, 4 core, 5 core cable
Material : XLPE
Hot-melt adhesive

Tape type
Voltage : 0.6/1kV
Type : Plastic-insulated cables
Core : 3 core, 4 core, 5 core cable
Material : insulating vulcanized tape and electrical tape
Cross Section : 70 ~ 150mm2
With- or without screen

Resin Joint type


Voltage : 0.6/1kV
Type : branch or straight type
Compression or mechanical
Cross Section : 4 ~ 400mm2
Armour bond
HF and No toxic emission

10 AirSolTM 4.Power Infra 4.2 PI-J :Joint


Carpet

5.Bridge

Power & Control

Bridge
5
Bridge
5.1 BR-PC : Power & Control
Br-PC 3

5.2 BR-C : Carpet


Br-C 4
AirSolTM 5.1 Bridge, Power & Control
Power & Control Cable Table

Conductor Diameter
Rated Number of Corss Section Conductor
Insulation Sheath Construction of Jacket
Voltage Cores Material
(mm2) (No./mm) (mm)

5 0.75 30/0.18 12.2~12.5

3 2.2 12.7~13.3

4 2 13.9~14.6
65/0.203
12 2 21.4~22.5

24 2 29~30.5

LV Cable ~600V EP 4 5.5 CR 7/ 41/ 0.16 Cu 18.3~19.2

5 22 19/ 85/ 0.16 33.5~35.2

1 60 19/ 85/ 0.254 20.2~22.0

1 90 37/ 76 /0.2 23.5~24.6

1 120 37/ 65/ 0.254 26~27.3

1 150 37/ 41/ 0.361 28.7~30.1

Conductor Diameter of
Rated Number of Number of Shield Conductor
Insulation Sheath Construction Jacket
Voltage Cores Wire (%) Material
(No./mm) (mm)

Braid
2x20AWG 2 Pair PVC 26/0.16 Cu 8.6~9.0
80
Control
300V XLPE
Cable
Braid
2x16AWG 2 Core PVC 65/0.16 Cu 7.4~7.9
80

5.1 Br-Pc : Power & Control AirSolTM 5.Bridge 3


AirSolTM Br-C
PURGOTEX Flocked Carpet

PURGOTEX
The value of Airport starts with the floorings in boarding bridge. PURGOTEX adds a uniquely
stylish ambience to boarding bridge floors. Carpet also makes for easy maintenance,
overcoming a key shortcoming of other carpet products.
Originality that surpasses all others. Check out our Flocked carpet.

Application
Boarding bridge

Design Standard
DIN 51097 Slip assessment ‘ 0.7’
ISO 105 B02:2000 ‘7 grade’
BS EN 1963:1997 Method A ‘Class 33’

Description Maintenance

❶ ❷ ❸
Photo Cleaning (Using Water)
1.Remove dirt with cleaning
tool
2. Rubbing with cleanser
bubble
3. Remove soap subs
4~5. Clean the carpet with a
dry floor cloth
❹ ❺

Color
Bamboo Cross Maple Spawn Touch

4 AirSolTM 5.Bridge 5.2 Br-C : Carpet


6.Air Rail

6
Air Rail
Air Rail
6.1 AR-P : Power
High Voltage
AR-P-H36/66kV 4
Medium Voltage
AR-P-M 5
AR-P-M8.7/15kV 7
Low Voltage
AR-P-M6/10kV 8
AR-P-LA600V 9
AR-P-L450/700V KVI 10

6.2 AR-R : Rail


Conductor Rail
AR-R-C 11
AirSolTM 6.1 Air Rail, Power
Power Cable Table

Rated Cross Section Screening / Temperature Material of


Insulation No. of Core Sheath Page
Voltage (mm2) Armour ( ) Conductor

HV -25~
33/66kV XLPE 1 240~2000 PE/PVC Aluminum Copper 4
Cable +90

12/20, XLPE -25~


1/3 1000/400 PE/PVC Metal Copper 5
18/30kV TR-XLPE +90

MV -25~
8.7/15kV EPR 1/3 - PE/PVC - Copper 7
Cable +90

Semi &
16~630/
6/10kV XLPE 1/3 FR-PVC Copper ~+90 Copper 8
16~300
Tape

XLPE/ -25~
600/1000V 2, 4 16~95 PVC - Aluminum 9
PVC +70/90
LV
Cable
450/750V PVC 1 1.5~240 - - ~+90 Copper 10

6.1 AR-P : Power AirSolTM 6.Air Rail 3


AirSolTM AR-P-H 36/66kV
MV Power Cable 36/66kV

Construction
Conductor Copper
Insulation XLPE
Sheath Aluminum
Sheath PE (PVC)

Continuous Current Ratings for Single Circuit(A)


Cross Section In Air
Direct Buried Pipe Duct
(mm2) Trefoil Flat (S=2D)

240 524 491 598 671


300 592 556 682 770
400 671 631 781 888
500 762 714 894 1025
630 878 808 1023 1187
800 965 928 1150 1355
1000 1119 1075 1361 1615
1200 1198 1146 1460 1745
1600 1352 1357 1654 2030
2000 1468 1475 1800 2273

Constructional Data (Nominal Values)


Conductor Thickness of Insulation Thickness of Thickness of Thickness of Outer Weight Max. DC
Conductor Screen Thickness Insulation Screen Aluminum Outer Diameter of Conductor Capacitance
Cross Section Approx. Approx. Sheath Sheath of Cable Cable Resistance at 20
Shape Diameter
(mm2) (mm) (mm) (mm) (mm) (mm) (mm) (kg / m) ( / km) ( nF/ km)
240 18.1 1.0 11.0 1.0 1.6 3.5 69 5.5 0.0754 0.20
300 20.4 1.0 11.0 1.0 1.6 3.5 72 6.3 0.0601 0.21
Compact
400 23.2 1.0 11.0 1.0 1.7 3.5 75 7.2 0.0470 0.23
Round
500 26.3 1.0 11.0 1.0 1.8 4.0 79 8.6 0.0366 0.25
Stranded
630 30.2 1.0 11.0 1.0 1.8 4.0 83 10.1 0.0283 0.28
800 34.0 1.0 11.0 1.0 1.9 4.0 87 12.0 0.0221 0.30
1000 38.7 1.0 11.0 1.0 2.0 4.0 92 14.4 0.0176 0.33
Segment
1200 41.8 1.0 11.0 1.0 2.1 4.5 98 16.7 0.0151 0.36
Stranded
1600 48.1 1.0 11.0 1.0 2.2 4.5 105 20.9 0.0113 0.40
(Miliken)
2000 54.3 1.0 11.0 1.0 2.4 4.5 112 25.4 0.0090 0.44

Other dimensions available on enquiry.

4 AirSolTM 6.Air Rail 6.1 AR-P : Power


AirSolTM AR-P-M
MV Power Cable 12/120kV, 18/30kV

Application
Connect a railway substation to a station

Design Standard
IEC 60502, 61034, 60754

Construction
Conductor Annealed copper, Hard aluminum stranded
wires, Compacted circular and segmental
compacted circular
Conductor 1core (12/20kV : 35mm2 ~ 1000mm2)
Cross (18/30kV : 50mm2 ~ 1000mm2)
Sectional Area 3core ( ~ 400mm2)
Insulation XLPE, TR-XLPE
Sheath PVC(ST2), PE(ST7), Halogen-free(ST8)
Metallic screen Copper tape or wire shield Technical Data
Color 3 core (Red, Yellow, Blue) Voltage 12/20kV, 18/30kV

12/20kV MV Power Cable


Conductor Insulation Sheath Apporx. D.C Conductpr Test Approx.
Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
Nominal Cross Section Construction Diameter
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
35 4.7 5.5 1.8 27 0.524 42 860
50 8.1 5.5 1.8 28 0.387 42 1010
70 9.8 5.5 1.8 30 0.268 42 1250
95 11.4 5.5 1.9 31 0.193 42 1530
120 12.9 5.5 1.9 33 0.153 42 1790
150 Compacted 14.4 5.5 2.0 34 0.124 42 2090
185 Circular 15.9 5.5 2.0 36 0.0991 42 2470
240 18.3 5.5 2.1 39 0.0754 42 3060
300 20.5 5.5 2.2 41 0.0601 42 3680
400 23.2 5.5 2.3 44 0.0470 42 4540
500 26.4 5.5 2.4 47 0.0366 42 5620
630 30.2 5.5 2.5 52 0.0283 42 7040

Other dimensions available on enquiry.

6.1 AR-P : Power AirSolTM 6.Air Rail 5


AirSolTM AR-P-M

18/30kV MV Power Cable


Conductor Insulation Sheath Apporx. D.C Conductpr Test Approx.
Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
Nominal Cross Section Construction Diameter
(mm2) (No / mm) (mm) (mm) (mm) (mm) ( / km) (kV) (kg / km)
70 9.8 8.0 2.0 36 0.268 63 1720
95 11.4 8.0 2.1 38 0.193 63 2040
120 12.9 8.0 2.1 40 0.153 63 2360
150 14.4 8.0 2.1 41 0.124 63 2670
185 Compacted 15.9 8.0 2.2 43 0.0991 63 3110
240 Circular 18.3 8.0 2.3 46 0.0754 63 3820
300 20.5 8.0 2.4 48 0.0601 63 4510
400 23.2 8.0 2.5 51 0.0470 63 5440
500 26.4 8.0 2.5 55 0.0366 63 6600
630 30.2 8.0 2.7 60 0.0283 63 8300

Other dimensions available on enquiry.

6 AirSolTM 6.Air Rail 6.1 AR-P : Power


AirSolTM AR-P-M 8.7/15kV
MV Power Cable 8.7/15kV

Application
Connect a substation to a station

Design Standard
IEC 60092-350, -354, -359, IEC 60332-1, -3, IEC 60502-2

Construction
Conductor Tinned annealed copper
Conductor Screen Semi-conductive tape plus compound
Insulation Material XLPE
Insulation Screen Semi-conductive compound plus tape
Metallic Screen Copper tape
Inner Covering High modulus PVC
Sheath Material Enhanced PVC to IEC 60092-359
Conductor Cross
25 ~ 185mm2
Sectional Area Technical Data
Core 3 core (Red, white, blue) Voltage 8.7 / 15 kV

Cross Section Outer Diameter Approx. Weight


No. of Cores
(mm2) (mm) (kg / km)

1/3 25 25.8 / 51.6 800 / 2690

1/3 35 27.1 / 54.8 930 / 3200

1/3 50 28.7 / 58.4 1130 / 3850

1/3 70 30.6 / 62.3 1370 / 4660

1/3 95 33.4 / 67.6 1720 / 5740

1/3 120 35.1 / 71.7 1930 / 6510

1/3 150 37.0 / 75.6 2350 / 7880

1/3 185 38.9 / 79.7 2650 / 8880

1 240 41.5 3340

1 300 44.6 4040

Other dimensions available on enquiry.

6.1 AR-P : Power AirSolTM 6.Air Rail 7


AirSolTM AR-P-M 6/10kV
MV Power Cable 6/10kV F-CV

Application
Power cable used for residential and commercial buildings and industrial distribution circuits

Design Standard
IEC 60502-2

Construction
Conductor Compacted or circular stranded annealed copper class 2
Insulation 90 Crosslinked polyethylene(XLPE)
with semi-conducting inner & outer screen
Shield The semi-conducting tape and copper tape shield is applied
helically over the each core
Assembly Multi-cores of cable shall be assembled to form a circular cable
Sheath Black flame retardant PVC (FR-PVC)

Core Identification
1 core XLPE natural color
3 cores black, white, red

6/10kV F-CV (Single Core)


Conductor Insulation Sheath Apporx. Conductor Test Approx.
Nominal Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No/mm) (mm) (mm) (mm) (mm) ( /km) (kV) (kg/km)

16 4.7 1.5 20 1.15 460


1.5
25 5.9 21 0.727 570
35 6.9 22 0.524 700
1.6
50 8.1 23 0.387 840
70 9.8 25 0.268 1100
1.7
95 11.4 27 0.193 1380
120 Compacted 12.9 3.4 28 0.153 21 1660
3.4 1.8 21
150 ¿ł˙ —ˆ¿‹…–
Circular 14.4 30 0.124 1950
185 15.9 1.9 32 0.0991 2360
240 18.3 35 0.0754 3010
2.0
300 20.5 37 0.0601 3650
400 23.2 40 0.0470 4520
2.1
500 26.4 43 0.0366 5650
630 30.2 2.3 48 0.0283 7230

6/10kV F-CV (3 Core)


Conductor Insulation Sheath Apporx. Conductor Test Approx.
Nominal Cross Section Construction Outer Diameter Thickness Thickness Overall Diameter Resistance(20 ) Voltage Weight
(mm2) (No/mm) (mm) (mm) (mm) (mm) ( /km) (kV) (kg/km)

16 4.7 2.1 39 1.15 1360


25 5.9 2.2 41 0.727 1760
35 6.9 2.3 43 0.524 2140
50 8.1 2.4 46 0.387 2620
70 Compacted 9.8 2.5 50 0.268 3400
95 ¿ł˙ —ˆ¿‹…– 11.4 3.4 2.6 53 0.193 21 4350
Circular
120 12.9 2.7 57 0.153 5200
150 14.4 2.8 60 0.124 6180
185 15.9 2.9 64 0.0991 7450
240 18.3 3.1 69 0.0754 9430
300 20.5 3.3 74 0.0601 11530
Other dimensions available on enquiry.

8 AirSolTM 6.Air Rail 6.1 AR-P : Power


AirSolTM AR-P-LA 600V
LV Power Cable 600V Aluminum

Application
Power supply to signal equipment

Design Standard
BR880, BS 5467, BS 6346 (British rail standard)

Construction
Conductor Sector shaped solid aluminum
Insulation XLPE or PVC Technical Data
Separator PETP Voltage 600/1000 V
Sheath PVC (BK) Operation Temp. -25 ~ +70 (BS6346) or, + 90 (BS5467)

Positive Track Cables (600/1000V PVC Insulation & PVC sheath cable)
Insulation Sheath Nominal Nominal
Construction
Thickness Thickness Overall Diameter Weight
(No / mm) (mm) (mm) (mm) (kg/km)

2 / 16 1.0 1.8 14.3 420

2 / 25 1.2 1.8 16.6 455

2 / 35 1.2 1.8 18.0 525

2 / 50 1.4 1.8 20.4 620

2 / 70 1.4 1.9 22.8 840

2 / 95 1.6 2.0 26.2 1020


4 / 70 1.4 2.0 30.6 1750

4 / 95 1.6 2.2 35.5 2100

Other dimensions available on enquiry.

6.1 AR-P : Power AirSolTM 6.Air Rail 9


AirSolTM AR-P-L 450/700V KVI
LV Power Cable 450/700V KVI

Application
Type KIV is suitable for wiring on panel boards, switchboards and control apparatus at
max conductor temperature at 70

Design Standard
IEC 60227-3

Construction
Conductor Flexible stranded annealed copper
Insulation Abrasion-and moisture-resistant PVC

450 / 750V KIV


Conductor Insulation Approx. Overall Diameter Conductor Resistance(20 ) Insulation Approx.
Nominal Outer Thickness Resistance Weight
Minimum Maximum Non Plated Plated
Cross Section Diameter (70 )
(mm2) (mm) (mm) (mm) (mm) ( /km) ( /km) (M .km) (kg/km)
1.5 1.6 0.7 2.8 3.4 13.3 13.7 0.010 30
2.5 2.1 0.8 3.4 4.1 7.98 8.21 0.009 40
4 2.6 0.8 3.9 4.8 4.95 5.09 0.007 50
6 3.6 0.8 4.4 5.3 3.30 3.39 0.006 80
10 4.8 1.0 5.7 6.8 1.91 1.95 0.0056 130
16 6.0 1.0 6.7 8.1 1.21 1.24 0.0046 180
25 7.4 1.2 8.4 10.2 0.780 0.795 0.0044 280
35 8.7 1.2 9.7 11.7 0.554 0.565 0.0038 370
50 10.4 1.4 11.5 13.9 0.386 0.393 0.0037 500
70 12.5 1.4 13.2 16.0 0.272 0.277 0.0032 700
95 14.5 1.6 15.1 18.2 0.206 0.210 0.0032 970
120 16.2 1.6 16.7 20.2 0.161 0.164 0.0029 1,200
150 18.2 1.8 18.6 22.5 0.129 0.132 0.0029 1,490
185 20.2 2.0 20.6 24.9 0.106 0.108 0.0029 1,850
240 23.3 2.2 23.5 28.4 0.0801 0.0817 0.0028 2,440

Other dimensions available on enquiry.

10 AirSolTM 6.Air Rail 6.1 AR-P : Power


AirSolTM AR-R-C
Conductor Rail

Application
3rd rail power feeding for LRT, MGLEV

Design Standard
Customer design

Description
Alloy Others
Si Fe Cu Mn Mg Cr Zn Ti Al
Number Each Total
A6063 0.20 ~ 0.60 0.35 0.10 0.10 0.45 ~ 0.90 0.10 0.10 0.10 0.50 0.15 Leftover

Item Material Dimension Remark


Al T-Bar A6063-T5 1471mm2 12,000
Hex Bolt Set STS 304 M8 30
Contact Surface A6063-T5 -

Mechanical Properties
Tensile Strength Yield Strength Elongation
Al-Alloy
(N / mm2) (N / mm2) (%)
A6063-T5 157 108 8

Electrical Properties
Temperature
Modulus of Modulus of Thermal
Electrical Thermal Coefficient
Specific Mass Longitudinal Lateral Expansion
Conductivity Conductivity of Electrical
(20 , g/cm2) Elasticity Elasticity Coefficient
(20 , IACS ) (25 , kW/m ) Resistance
(kN / mm2) (kN / mm2) ( 10-6 / )
( 10-3 / )
51 2.7 70.6 26.2 23.4 0.21 4.2

6.2 AR-R : Rail AirSolTM 6.Air Rail 11


AirSolTM AR-R-C
Conductor Rail

Num. Item Dimension Material Quantity


1 Al-Conductor 12 m A6063-T5 1
2 Hex Bolt Set M8 30 STS 304 47
3 Washer M8 A6063-T5 94
4 Spring Washer M8 STS 304 47
5 Hex Nut M8 STS 304 47

Stainless Steel

Aluminum Conductor

Other dimensions available on enquiry.

12 AirSolTM 6.Air Rail 6.2 AR-R : Rail


7
7.The Others

Others
The Others
Others
The Others
7.1 TO-F : Flooring
TO-F 3

7.2 TO-HS : Heat Shrinkable Tube


TO-HS 4

7.3 TO-HC : Heating Cable


TO-HC 5

7.4 TO-CT : Cables Tube


TO-CT 6

7.5 TO-LED : LED Lighting


TO-LED 7
AirSolTM TO-F
Rubber Flooring(Softrong)

Application
Rubber flooring in a station, Airport terminal floor

Design Standard
ASTM F1344 or EN1817

Description
Round / Round Chip Stair Treads

Hammered / Neo-Hammered Neo-Stone / Slate

Chacteristics : non-slip, abrasion resistance, reduce noise etc.

Dimension Color

Product Type Dimension(mm) Application

Round 4.0(T) 500 500


Station,
Stair 1.2 5.0(T) 480 1200
building
Stair 1.5 5.0(T) 480 1500
Soild Type exhbitions /
Stair 1.8 5.0(T) 480 1800
converntion
Slate 3.5(T) 500 500
center stc.
Hammered 3.0(T) 500 500
Softrong
Round Chip 4.0(T) 500 500 Station,
Stair 1.2 5.0(T) 480 1200 building,
exhbitions /
Stair 1.5 5.0(T) 480 1500 converntion
Chip Type
Stair 1.8 5.0(T) 480 1800 center,
school,
Neostone 3.0(T) 500 500
gymnasium
Neohammered 3.0(T) 500 500 stc.

Other dimensions available on enquiry

7.1 TO-F : Flooring AirSolTM 7.The Others 3


AirSolTM TO-HS
Heat Shrinkable Tube

Shrink Ratio Temperature Grade Special Feature GSHS-1625LT


1 indicates 50% (2:1) 05 indicates 105 T for Thin-wall Shrink Ratio Special Feature
2 indicates 30% (3:2) 25 indicates 125 W for Waterproof with an adhesive Voltage Grade Temperature Grade
3 indicates 65% (3:1) 35 indicates 135 N for Non flame retardant
4 indicates 75% (4:1) 50 indicates 150 S for Semi-rigid
75 indicates 175 F for Flexible
Voltage Grade 90 indicates 90 LT for Shrinkable at low temperature
3 indicates 300V G for Non toxic
6 indicates 600V HF for Halogen-free
Except for 6 in 1625T,
which indicates 150V

4 AirSolTM 7.The Others 7.2 TO-HS : Heat Shrinkable Tube


AirSolTM TO-HC
Heating Cable MAT

Application
Asphalt, roof, out door

Construction
Twin conductor heating cable
Mat Width Small area _ 40cm
Large area _ 80cm
Conductor Solid resistance wire
Insulation XLPE
Screen Conductive polymer
Jacket PVC
Overall Diameter 7.5mm

Technical Data
Power 1100~3300 W
Asphalt temp Max 160
Bending Radius 5 x cable diameter
Rated voltage 230V

Product List
Output Mat Width Mat Length Mat Area Resistance
(W) (m) (m) (m2) ( )
1100 0.4 9.0 3.6 48.1
1500 0.4 12.0 4.8 35.3
1800 0.4 14.5 5.8 29.4
2150 0.4 17.2 6.9 24.6
2600 0.8 11.0 8.8 20.3
3300 0.8 13.9 11.1 16.0

Other dimensions available on enquiry.

7.3 TO-HC : Heating Cable AirSolTM 7.The Others 5


AirSolTM TO-CT
Plastic Cable Tube

Application
Optical fiber direct buried tube

Design Standard
KSC-8454

Construction
Material PE
Hard External Pressure
Semi-Permanent
Light Weight

Technical Data
Dielectric Strength AC2KV/15min
Dielectric Resistance Over 100
Length Margin of Error 2%

Product List
Output Mat Width Mat length Mat area
(W) (m) (m) (m2)
19 14 2.5 100
21 16 2.5 100
27.5 22 2.75 90
34 28 3.0 90
42 36 3.0 60
48 42 3.0 60
60 48.8 4.8 40
76 64.5 4.8 40
89 74.2 6.3 40
114 90 6.0 4 or 6

Other dimensions available on enquiry.

6 AirSolTM 7.The Others 7.4 TO-CT : Cables Tube


AirSolTM TO-LED
LED Products

Application
Indoor / Outdoor Lighting
Decorative Lighting
Display & Signage

Product Line-Up (RGB Products)

Product Model No. Specification

C-STRIP C-STRIP RGB LM6-5252BS02 30cm, Indoor, 3in1 SMD LED(20), 4.8W

CF-STRIP CF-STRIP RGB LM6-5252BF02 30cm, Indoor, 3in1 SMD LED(20), Flexible PCB, 4.8W

DRIVE BOARD
Drive board ML-DB0770L 30cm, Indoor, 3in1 SMD LED(20), Flexible PCB, 4.8W
(for C-STRIP&CF-STRIP RGB)
TUBE-STRIP
TUBE-STRIP RGB LM6-5252BT03 30cm, Indoor, 3in1 SMD LED(20), Flexible PCB, 4.8W
RGB

C-PANEL RGB 15x15cm, Indoor, 3in1 SMD LED(16), DIP switch, 5.76W
C-panel ML-PI0406NTDA
C-PANEL RGB 25x25cm, Indoor, 3in1 SMD LED(16), Auto addressing

MODULE FOR RGB MODULE


- 55x12x8.5, 0.72W, 12Vdc
SIGN PANEL (LED 2pcs inside, DC 12V)
336mm, SMD LED(14), 5W
336mm, SMD LED(14), water proof, 5W
LINEAR BAR LINEAR BAR RGB -
1,236mm, SMD LED(64), 18W
1,236mm, SMD LED(64), water proof, 18W
MP-9 Outdoor, 3in1 SMD LED(4), square case, 2W for 1 module
ML-PD0430NTAA
MP-9 Indoor, 3in1 SMD LED(4), square case, 2W for 1 module
MP-2 Outdoor, 3in1 SMD LED(2), round case, 2W for 1 module
ML-PD0242NTAC
PDS SYSTEM MP-2 Indoor, 3in1 SMD LED(2), round case, 2W for 1 module
(VIDEO TYPE) SCU - Indoor, DVI(Video) type
INTERFACE - Indoor, DMX type
MCU - MAIN CONTROLLER(VIDEO CONTROLLER), including cable to PC & Monitor
PC + MONITOR - PC + MONITOR
MP FLEX(4) Outdoor, 3in1 SMD LED(4), DMX type, round case, 25W for 10 modules
MP-FLEX ML-IC0432UTAC
MP FLEX(4) Indoor, 3in1 SMD LED(4), DMX type, round case, 25W for 10 modules
GLOW RGB ML-BI0112NFDA 30cm, Indoor, oval lamp LED(R15/G15/B15), DIP switch, 5.4W
GLOW GLOW RGB ML-BI0312NFDA 30cm, Indoor, oval lamp LED(R24/G24/B24), DIP switch, 7.2W
GLOW RGB ML-BI0112NTDA 30cm, Indoor, 3in1 SMD LED(15), DIP switch, 6.8W
GLOW SUPER RGB ML-BO0118LFAA 45cm, Outdoor, high-power LED(18) - Drive board is not including, 25W
GLOW SUPER RGB ML-BO0118LFAA 60cm, Outdoor, high-power LED(24) - Drive board is not including
GLOW SUPER GLOW SUPER RGB ML-BO0118LFAA 90cm, Outdoor, high-power LED(36) - Drive board is not including
DMX512 Standard (RS485), 84Ch(Default) / 512Ch(Option),
DRIVE BOARD -
DC24V(5W)
GLOW SLIM RGB - 30cm 30cm, Indoor, 3in1 SMD LED(18), Auto addressing, 5W
GLOW SLIM GLOW SLIM RGB - 50cm ML-BI1812UTAA 50cm, Outdoor, 3in1 SMD LED(24), Auto addressing
GLOW SLIM RGB - 50cm 50cm, Indoor, 3in1 SMD LED(24), Auto addressing

7.5 TO-LED : LED Lighting AirSolTM 7.The Others 7


AirSolTM TO-LED

Product Line-Up (RGB Products)

Product Model No. Specification

FLAT SHOT RGB (25W) ML-FS1806LFAA Outdoor, high-power LED(18), 25W


FLAT SHOT
FLAT SHOT RGB (50W) ML-FS3612LFAA Outdoor, high-power LED(36), 50W

FLAT STAGE RGB ML-FS0924MFRA Indoor, Oval lamp LED(648), 55W


FLAT STAGE
PROJECT LIGHT - 275x294x118, Outdoor, 85W, 3000K/5200K

AQUA MAGIC RGB (NEW CASE) ML-AS1254LFAB Outdoor, high-power LED(12), SUS case, 25W
AQUA SHOT
AQUA SHOT RGB ML-AS5490NFAA Outdoor, Oval lamp LED(54), SUS case, 4.8W
DMX POWER 150W ML-PW150LT Indoor, 150W, 24V
DMX POWER DMX POWER 320W ML-PW320LT Indoor, 320W, 24V
DMX POWER 600W ML-PW600LT Indoor, 600W, 24V
SMPS 150W - Indoor, 150W, 24V
SMPS SMPS 320W - Indoor, 320W, 24V
SMPS 600W - Indoor, 600W, 24V
IMP 1 (MINI CONTROLLER) ML-CT0084MA Indoor, 84ch DMX controller
CONTROLLER E:cue DMX2 - Indoor, 1024ch DMX controller
DAS LIGHT ML-CT0512VA Indoor, 512ch DMX controller

ADDRESS WRITER ADDRESS WRITER ML-WR512LT 3.6W, 20~24Vdc, DMX512, Auto Addressiong, RGB(3Ch)

8 AirSolTM 7.The Others 7.5 TO-LED : LED Lighting


AirSolTM TO-LED

Product Line-Up (White Products)

Product Model No. Specification

C-STRIP C-STRIP WHITE LM6-5252BS01 30cm, Indoor, SMD LED(20) , 4.8W

CF-STRIP C-STRIP WHITE LM6-5252BF01 30cm, Indoor, SMD LED(20), Flexible PCB, 4.8W

TUBE-STRIP WHITE LM6-5252BT01 6m, WATER PROOF, SMD LED (240), 12W/m
TUBE STRIP
TUBE-STRIP BLUE LM6-5252BT02 6m, WATER PROOF, SMD LED (240), 12W/m
C-PANEL WHITE LM7-5630RS01 LM7-5630RS01
C-PANEL WHITE LM7-5630RS02 LM7-5630RS02
C-PANEL WHITE 4CH ML-PI1606UWAD ML-PI1606UWAD
C-PANEL WHITE 9CH ML-PI3606UWAE ML-PI3606UWAE
C-PANEL
C-PANEL WHITE 2CH ML-PI3606UWAC ML-PI3606UWAC
C-PANEL WHITE ML-PI7206UWAC ML-PI7206UWAC
C-PANEL WHITE ML-PI1609UWNA ML-PI1609UWNA
C-PANEL WHITE LM12-5630EM03 LM12-5630EM03
ML-CL0212UWNB (Warm)
SMD LED(2) - STANDARD (3000/4000/6500K), 0.6W
White module ML-CL0212UCNB (Cool)
(LED 2pcs inside, DC 12V)
- 55x12x8.5, 0.72W, 12Vdc

ML-CL0412UWNB (Warm)
SMD LED(4) - STANDARD (3000/4000/6500K), 1.2W
MODULE FOR ML-CL0412UCNB (Cool)
SIGN PANEL White module
- 52x40x8.7, 1.44W, 12Vdc
(LED 2pcs inside, DC 12V)

- 36x30x3.1, 2.2W, 12Vdc

AC - 55x45x10.5, 1.8W, 100Vac

MR16 GX5.3 (12V) 5W MR16-GX5.3-5W


MR16 E27 5W MR16-E27-5W 12V AC/DC (3300K/5500K) 15°/40°/60°
MR16 GU10 5W MR16-GU10-5W
MR16 GX5.3 (12V) 6.5W MR16-GX5.3-6.5W
MR16 E27 6.5W MR16-E27-6.5W 12V AC/DC (3300K/5500K) 15°/40°/60°
MR16 GU10 6.5W MR16-GU10-6.5W
MR16 GX5.3 (12V) 4W MR16-GX5.3-4W
MR16 E27 4W MR16-E27-4W 3*1W 12V AC/DC (3300K/5500) 60°
SPOT LIGHT MR16 GU10 4W MR16-GU10-4W

PAR30 7.5W PAR30-7.5W 7*1W PAR30 AC90~240V (3000K/5200k) 15°/30°/45°

AR30 8.5W PAR30-8.5W 7*1W PAR30 AC90~240V (3000K/5200k) 30°

PAR30 Track System PAR30 7*1W PAR30 AC90~240V (3000K/5200k) 30°

PAR30 10W PAR30-10W AC100~240V (5000K) 130°

BULB BULB 9.5W - AC85~265V (5,000K) 120°, 9.5W

6*1W LED, 24V (3000K/5200k), 30CM


INTER CONNECTOR
LINEAR BAR ABINET LINEAR LIGHT - EXTENSION CABLE 20CM
POWER ADAPTER 30W
POWER ADAPTER 50W

7.5 TO-LED : LED Lighting AirSolTM 7.The Others 9


AirSolTM TO-LED

Product Line-Up (White Products)

Product Model No. Specification

L01 306mm, SMD LED(6), 7W


336mm, SMD LED(16)
L02-300
LINEAR BAR LINEAR BAR 336mm, SMD LED(16), water proof
1,236mm, SMD LED(64)
L02-1200
1,236mm, SMD LED(64), water proof
MA-T812 120*0.2W LED, (6500K/4500K), 580mm + 40V SMPS
MA-T824 120*0.2W LED, (6500K/4500K), 1198mm + 40V SMPS
T8 TUBE LIGHT MA-T825 120*0.2W LED, 6500K, 1200mm
T8 LED LAMP
(HIGH-BRIGHTNESS) T8-SMPS SMPS FOR T8 TUBE
- 1212mm, 21W, 6000K, 120LEDs
- 593mm, 11W, 6000K, 60 LEDs

T10 TUBE LIGHT T10 TUBE LIGHT MA-T10 28W (6000K) 120cm, AC type product

595 x 595 x 51.7mm, 288LED (Installation : T-BAR Frame), 52W


-
610 x 610 x 51.7mm, 288LED (Installation : M-BAR Frame), 52W
DIRECT HIGH-BRIGHTNESS
295 x 1195 x 51.7mm, 288LED (Installation : T-BAR Frame), 52W
-
310 x 1210 x 51.7mm, 288LED (Installation : M-BAR Frame), 52W
- 600 x 600, 288 LED, 58W, 3000/4000/6500K
PANEL - 150 x 600mm, 144LED (Installation : T-BAR Frame)
LIGHT - 300 x 300mm, 144LED (Installation : T-BAR Frame)
EDGE -
- 150 x 150mm, 48LED (Installation : T-BAR Frame) W/O SMPS
- POWER ADAPTER 10W for 150x150 size
- SMPS (POWER SUPPLY) 60W

LINEAR STANDARD - 633.4x 120x 63.5mm, 300LED, 22.5W, SMPS included (inside),

GLOW GLOW WHITE (3CH) ML-BI1512NWAA 30cm, Indoor, SMD LED(15), DIP switch, 3ch

GLOW SUPER WHITE 45cm, Outdoor, high-power LED(18)


ML-BO0118LWAA
GLOW SUPER WHITE 60cm, Outdoor, high-power LED(24)
GLOW SUPER
GLOW SUPER WHITE 90cm, Outdoor, high-power LED(36)
ML-B01618LWAA
GLOW SUPER WHITE (120cm) 120cm, Outdoor, high-power LED(48)

10 AirSolTM 7.The Others 7.5 TO-LED : LED Lighting


AirSolTM TO-LED

Product Line-Up (White Products)

Product Model No. Specification

GLOW SLIM WHITE - 30cm 30cm, Indoor, SMD LED(18),only ON/OFF


GLOW SLIM GLOW SLIM WHITE - 50cm - 50cm, Outdoor, SMD LED(24), only ON/OFF
GLOW SLIM WHITE - 50cm 50cm, Indoor, SMD LED(24), only ON/OFF

FLAT SHOT FLAT SHOT WHITE (50W) ML-FS3612LWAA Outdoor, high-power LED(32), 50W

LMFL-101 (120W) - HIGH BRIGHTNESS LMFL-101 AC200~240V, 5000~7000K, 96LED,156°Δ


LMFL-102 (90W) - HIGH BRIGHTNESS LMFL-102 AC200~240V, 5000~7000K, 72LED,156°Δ
FACTORY LIGHT
120W - AC80~265V, 5000K, 96 LED, f266 x 177mm

115W, AC200~240V, 5000~7000K, 96LED, 117°Δ


LMSL-902 -
LMSL-902 155W, AC200~240V, 5000~7000K, 128LED, 117°Δ
HIGH BRIGHTNESS
STREET LIGHT 195W, AC200~240V, 5000~7000K, 160LED, 117°Δ
LMSL-916 -
LMSL-916 100W, AC200~240V, 5000~7000K, 80LED, 130°
HIGH BRIGHTNESS
LMSWL-801(Sidewalk light) -
SECURITY LIGHT LMSWL-801 90W, AC200~240V, 5000~7000K, 72LED, 238°
HIGH BRIGHTNESS
LMPL-601(Project light) -
LMPL-601 82W, AC200~240V, 5000~7000K, 72LED, 152°
INDUSTRIAL HIGH BRIGHTNESS
LIGHT LMTL-707(Tunnel light ) -
LMTL-707 100W, AC200~240V, 72LED, 83°
HIGH BRIGHTNESS

7.5 TO-LED : LED Lighting AirSolTM 7.The Others 11