ECS-MRU for CNG station

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Engineering Commodity &

Services
MRU Station equipment
Mobile Refueling Unit ® HAMITECH COMPRESSORS
CONTENTS

Who We Are 4
What We Do 5
Executive Summary 6
Certification 8
What is Mobile Refueling Unit? 9
Compressor 13
Dispenser 14
Tube Cylinder 15
Compressor data sheet 16
Drawing 1. 17
Drawing 2. 18
4

We developed MRU (mobile Refueling Unit) according to the company's


philosophy that a company should . In addition to the company's profits,
the company must consider environment and future of the world in
addition to the profit of the company. Compared with already existing CNG
stations, HAMITECH's MRU are economical and efficient, including charging
times and maintenance costs, which is a clear drawback to CNG technology.

HAMITECH compressor are powering CNG stations around the globe. On all
continents, HAMITECH has built a reputation for safe, rugged and long
lasting equipment. The combination of advanced South Korean technologies
and vast industry experience makes the HAMITECH compressor one of the
most robust, continuous duty rated compressors in the CNG world scene.
5
Super robust HAMITECH
Mobile Refueling Unit ® technology

HAMITECH compressors are built to perform beyond expected and


specified requirements. We lead the world in the development of modern
MRU(Mobile Refueling Unit) ® compression technology with air-cooled,
high capacity rated design and market-driven innovation.

Utilizing the latest technologies, while drawing on years of experience, we


focus on design and innovation to produce rugged compressors fit for field
conditions around the world.

Our design approach matches specifically configures CNG compressors to


maximize operational efficiency. Our design philosophy results in low
material stresses and reduced bearing loads.

25~2.5 1,029 1 1/2 75


Visit agent at each local- let’s talk marketing,
budgeting and technical design
8

Certification
<Certificate of patent> <Certificate of CU product>

<International Industrial Certificate>


9

What is Mobile Refueling Unit?


10

1-3. Operating conditions of Mobile CNG station

Content DATA Unit


1 Tube Inlet pressure 250~10 Bar G.
2 Inlet Temperature 40 ℃
3 Final Outlet pressure 250 Bar G.

4 Charging time per one Car(20m3) 2~3 Min

5 Number of cylinder 2 EA
Maximum power not exceeding 50kW,
6 Power consumption
small use

7 Power-driven method Motor/ Engine

8 External use temperature -25/+45 ℃


9 Gas composition ratio normal

1-4. Comparison of specification with other company

No Content Unit Italy HAMI


1 Capacity(@80bar) Nm3/hr 600 1029
2 Charging Time( 15m3) min 7~11 3~4
3 Number of cylinder EA 4 2
4 Speed RPM 1500 1450
5 Cooling - Water Air
6 Power Driven - Engine Motor
2nd 12
7 Power consumption KW 68
1st 45
8 Compression method - Hydraulics Piston
9 Compression range Bar 250~25 same
10 Compressor operating temperature ℃ -10~+45 -25~+50

11 Explosion-proof safety certification - Normal CNG


11

1-5. Comparison MRU with other company

1-5-1. Maintenance

OTHER HAMI TECH

VS

- Complex in structure - Easy to disassemble and assemble


- Impossible to handle without engineer - Simple structure
- Slow Maintenance - Fast Maintenance

1-5-2. Charging time

OTHER HAMI TECH

12 VS 4
- 12~15 minute per one car - 3~4 minute per one car
- Capacity : 600Nm3/HR(based @80bar) - Capacity : 1029Nm3/HR(based @80bar)
- 140 Number of car charged per day - 360 Number of car charged per day
12

1-5-3. Price

OTHER HAMI TECH

VS

1-5-4. Explosion-proof safety certification

OTHER HAMI TECH

VS
CNG CNG

Explosion-proof : Normal Exd ⅡB T4


“Best safety”
13

Compressor

- Model : HNK100-C75
- Inlet pressure(bar) : 250~25
- Outlet pressure(bar) : 250
- Capacity(Sm3/hr) : 1029Nm3/hr
- Air cooled type, 2stage
- electric motor : 100HP(75kW x 380V x 3P x 50Hz)
- Control power : 220V x 1P x 50Hz
- Inter & After Cooler
- Suction filter & inter stage snubber
- 1st & 2nd safety valve
- Anchor bolt & nut
- Instrument for one common bed
- inter wiring for compressor
- Ambient temp : -25℃ ~ + 50℃
- Explosion-proof : TEFC x IP 54(Exd ⅡB T4)
- Blow down system
- Alarm & shutdown for suction press
- alarm & shutdown for discharge temp & press
- Aux. oil pump & oil heater
- PLC Control panel
- Operating mode of CNG station : 24 hours

Location <Uzbekistan, Khorezm Region>


14

Dispenser

- Type : dual hose(bus, automobile)


- Design pressure : 352 bar
- Working pressure : 275 bar
- Digital display(sale, amount, pressure)
- Flow meter : KG80
- Control : C4000
- Main power : AC220V x 1P x 50Hz
- Standard : ASME code

<Container>
15

Tube Cylinder

- Model : TT12-1045 CNG


- Code & Standard : ISO-11120
- Application size : 1045
- Max. Filling pressure(bar) : 250(3625psi)
- Hyd. Test pressure(bar) : 375(psi)
- Outer diameter(OD) : 558.8mm
- Total weight : 23,185kg
- Capacity : 12,540 liter(1245Lx 12ea)
- Skid : according to ISO 668
16

Compressor DATASHEET
17

Drawing 1.
18

Drawing 2.

You might also like