Download as pdf
Download as pdf
You are on page 1of 21
YUSHI Multilayer Measurement High-Temperature Measurement PM5 Gen2 Coating Measurement OThin Steel Plate Measurement Ultrasonic Thickness Gauge OLarge Thick Part Measurement “Utility model patent for protective rubber boot of testing instruments: ZL 2020 2 1834019.3 “Appearance design patent for protective rubber boot of testing instruments: ZL 2020 3 0600327.9 Professional Solution to Various Thickness Measurement Difficulties What’s Different About This Ultrasonic Thickness Gauge? The PMS Gen2 ultrasonic thickness gauge is an advanced ultrasonic thickness gauge developed by YUSHI with multiple standard measurement functions and software options. This portable thickness gauge can meet most measurement requirements by using different frequencies and types of single element probes. Moreover, the mea- surement range is wide, ranging from 0.15mm thin steel plates to tens of meters long steel bars, and even tens of micrometers of thin paint layers, all of which can be measured. The fully functional PMS Gen2 is an innovative measuring instrument that integrates multiple solutions and can be effectively applied to most thickness measure- ‘ment applications. = = ~~ = ‘The PMS Gen2 ultrasonic thickness gauge can be used with delay line probes, contact probes, protective film probes, en probes, immersion probes and high temperature probes. The probe frequency range is 0.5-20MHz. and custom- ized probes and measurement fixtures can be used according to requirements to meet various measurement needs. The standard configuration of the PM5 Gen2 includes many powerful and easy-to-use measurement functions, as well as many options for special applications. These functional options can be used to solve measurement problems that cannot be achieved by standard instruments. The thickness of the oxide layer on the inner wall of the boiler tube can be measured extremely accurately, and multi-layer materials can also be measured in layers. The sealed housing is designed to meet the IP67, which can withstand harsh environments with humidity or dust, ‘The color TFT LCD display has large fonts, clear, bright and good visibility. The panel buttons of the thickness gauge are simple, and the operator can quickly enter the menu to access all functions. The instrument comes standard with a rubber protective boot with a bracket, which provides the best viewing angle of the screen during measurement and allows the instrument to be placed stably and operated with one hand. Thickness values measured using ultrasonic technol- ogy are accurate, reliable and repeatable. The main advantage of ultrasonic thickness measurement is that it can measure the thickness of closed containers and 4 sw other complex-shaped samples where itis difficult or impossible to reach both sides of the material, mea- . surement can be done from only one side of the sample material, the thickness reading can be obtained im- mediately without damaging the workpiece by cutting it. The PMS Genz ultrasonic thickness gauge is an in- dispensable testing tool in the non-destructive testing industry. Color Screen, Easy to Operate Durable and Reliable Performance The PMS Gen2 ultrasonic thickness gauge is designed to meet the requirements of harsh environments and differ- ent operating groups. The color TFT LCD screen with large font display is clear and bright in bright or dark light The sealed housing design meets IP67 dustproof and waterproof rating, allowing it to work normally in harsh condi tions that are wet or dusty. If you need an instrument that can verify the thickness reading through the waveform, the real-time color A-scan waveform adjustment function of the PMS Gen2 ultrasonic thickness gauge is very useful Simple key area provides direct access to all functions for easy operation. When on-site use, the standard rubber protective boot with bracket can keep the instrument stable. Clear and Bright Color Screen 2.4-inch (320*240 dots) color display LCD. Real-time color A-scan enables the user to see the color ultrasonic signal waveform directly on the screen, and any echo can be chosen through waveform adjustment. This is very useful for measurements that require verifying whether the thickness reading is correct. IP67 Dustproof and Waterproof + Passed IP67 test under GB/T 4208 standard Can be used in water less than 1 meter deep for a short period of time + Can be used in harsh environments such as water and sweat. Can prevent dust from entering (overall preventing contact and preventing dust penetration) Easy Operation 4 Simple key area ¢ Ergonomic design ¢ One hand operation ¢ Easy access to all functions of the instrument ¢ Standard rubber protective boot with bracket Can stably place the instrument to prevent dust from entering ¢ Prevent the instrument from being damaged due to accidental falling Normal Functions The basic measurement functions of the PMS Gen2 ultrasonic thickness gauge can meet most ultrasonic thickness measurement applications. The PMS Gen2 instrument is an easy-to-use thickness gauge when using its basic configuration, allowing the operator to complete the most common thickness applications with the most basic training, ‘¢ Most material measurements can be performed using single element transducers. Measuring Range: 0.01mm~38m, depends on materials, probe types and optional features. ‘¢ TDG Function: The initial pulse or interface echo can be effectively reduced by reducing the intial gain, and the bottom echo of the measured sample can be increased by increasing the maximum gain, making measurement easier. Measuring Mode: IE, KE-E, ME, AUTO, P-E, E-E, E-EV. Resolution: Standard display resolution is 0.001mm. Multiple Measurement Units: mm, inch, um, mil High-Temperature Measurement: Temperature up to 500°C ose ee Default System Configuration: For user convenience, the default conditions of the probes used by the instrument have been set, AUTO-Freeze Function: Calibration can be performed on frozen waveforms, as well as adjusting gain, range, delay, blank, ete. ¢ FullScreen Waveform Display Function: Increases the echo display area by 20%, giving the operator a large viewing window experience. ‘+ Echo Strength Indication: The stronger the echo, the more indicator bars are displayed, which is used in the digital display measurement interface where the waveform is not visible. + Time-Based B-scan Mode: Used to observe the bottom profile of the workpiece being measured. ¢ Differential/Reduction Rate Mode: Displays the difference between the measured thickness and the nominal thickness, and the percentage of the difference to the nominal thickness. ¢ Adjustable Gate Height: Only when the echo is higher than the gate, the instrument will capture the echo and obtain measurement values. ¢ Measuring Type: Standard, First Peak, Peak, Summit + Visual Measurement Point Identification: Phase 0°, 30°, 90°, 180° + Digital Amplification: The echo height will change correspondingly with the size of the multiplier, ranging from 1.010 7.0 times, + Calibration process with waveform displays, the waveform can be correctly adjusted to avoid calibration errors. 4 Various Zero Calibration Types: AUTO, AIR, DISK, BLOCK, DUAL-ECHO, set zero point. one-point calibration, two-point calibration. Normal Functions Material Velocity List: It is useful if the material sound velocity is unknown and the sample thickness cannot be obtained from the material Sound Velocity Range: 310m/s~18699mIs; 0.0122~0.7362 invus. + Probe Type: Delay line probe, Contact probe, Protective film probes, Pen probe, Immersion probe. Automatically matches the transmitted pulse according to the probe frequency. The sensitivity is 648 higher than the previous model, instruments have better narrow pulse waveform. + Rectification: RF, RF-, FULL, HALF+, HALF- + P67 dustproof and waterproof rating + Positive and Negative Dual Detection Polarity: The polarity of the echo signal is related to the relative acoustic impedance of the two media. The acoustic impedance of the two materials is reversed, their echo polarity will also be reversed. In such cases, itis necessary to change the relevant echo polarity settings to maintain measurement accuracy. Powerful Features in Practical Measurement Applications Time Dependent Gain (TDG) ‘The parameters of the Time Dependent Gain feature of PMS Genz include initial gain, TDG slope, maximum gain and starting point, Using TDG function, the initial pulse or interface echo can be effectively reduced by reducing the intial gain, and the bottom echo of the tested sample can also be increased by increasing the maximum gain for ‘easy measurement. ion Thickness Measurement TDG on Dual Detection Polarity Polarity refers to a state of the echo signal, which we usually express as positive or negative, ‘The polarity of the echo signal is related to the relative acoustic impedance of the two medium (density x sound velocity). In general, the bottom medium of the workpiece being measured is air, and the acoustic impedance of air is lower than that of metal, ceramic or plastic, so the echo polarity is negative. However, if the plastic layer on the metal surface is measured, the acoustic impedance of the two materials is reversed, their echo polarity will also be reversed. In such cases, it is necessary to change the relevant echo polarity settings to maintain measurement accuracy. Measuring Type ‘There are four types of ultrasonic echo: standard, first peak, peak and Summit In general, the instrument detects the highest positive peak or the highest negative peak on the waveform, which is. suitable for most measurement applications. When the backwall echo is irregular and contains several peaks with similar amplitudes, this conventional peak measurement method becomes unstable. The instrument measurement point will jump from one peak to another, and the thickness reading will change. In this case, in order to keep the instrument measurement point and thickness measurement stable, the echo type should be selected as First Peak Or Standard to detect the first peak among several waveforms with similar amplitudes, Correctly select the echo type according to the measurement conditions. Standard: First peak of the bottom echo through the gate First Peak: The first peak of a set of waves passing through the g Peak: The highest peak in a set of waves ‘Summit: The highest peak in all groups of waves Software Options The basic measurement functions of the PMS Gen2 ultrasonic thickness gauge can meet most ultrasonic thickness. measurement applications. When a special testing project cannot be measured, the user needs to purchase and use functional options other than the standard ones to improve the performance of the instrument. The PMS Gen2 instrument adds options for specific applications to solve the measurement problems that are not possible with standard instruments. + Storage Option The storage option can store 100,000 thickness values and 400 parameter configuration files, and equip with host computer software and USB disk. '# Window Mode Option The starting point and range of data collection are variable and consistent with the delay and range of the display window. The maximum delay is up to 38 meters. Make the measurement more flexible and efficient, increase the measurement range, improve the measurement speed, enhance digital noise reduction effect + Digital Noise Reduction Option Itis mainly used to reduce the interference of noise signals and effectively improve the signal-to-noise ratio. The effect is more significant when used with window mode. ‘# AUTO-Freeze Option Four trigger conditions can be set, the highest wave, the number of consecutive waves, the number of echoes, and the target thiokness range. When all rigger conditions are met at the same time, the waveform is automatically frozen + Directional Capture Option Five modes can be selected for directional capture, minimum value, maximum value, highest wave, most contin- uous waves, and most echoes. You can choose to automatically or manually display the captured waveform and thickness values. Temperature Compensation Option ‘The sound velocity of material changes with temperature, which affect the measurement accuracy. The temper- ature compensation function of PMS Gen2 will automatically perform temperature compensation calculations based on the input calibration test block temperature and actual workpiece temperature, and display the corrected thickness value High-Speed Measurement & Simultaneous Directional Display Options ‘Adjusted in 16Hz per, with window mode measurement rate up to 2KHz. Measurement speed is related to alarm, capture, auto-freeze, B-scan, and real-time transmission. The screen displays waveforms and thickness values synchronously at the set update rate, and 8 directional display schemes can be set. High Resolution Options The display resolution (IME mode) up to 0.0001mm, 0.1um, 0.00001in, 0.01mils. Large Range Options A composite measurement mode of the pulse-echo method, display range up to 38 meters, The focus is that maintaining high accuracy while maintaining a large range. * COAT Mode Option Include P-E measurement mode and coat measurement mode for the delay line probes. Measures thin coatings on wood, concrete, composite materials, metal, etc. Software Options * Double Layer Measurement Option Measure and display the thiokness of two layers of materials atthe same time, Includes multi-scan and time-difference function. Typical applications include double layer composites and coated metallic materials. + Oxide Layer Measurement Option Used to measure the thickness of the oxide layer on the inner wall of boiler pipe fitings. The thickness of the metal substrate and the oxide layer can be displayed simultaneously. Measuring range of the oxide layer is 0.25mm~1.25mm, by standard D15A probe, + Multi-Layer Measurement Option Measure and display the thickness of five independent layers at the same time, and can display the total thickness of all layers. It also includes dual-layer mode, multi-scan, and time-difference method functions, + Real-Time Communication Option The instrument can be controlled by the upper computer, and the thickness value, waveform and parameters can be transmitted in real time, including upper computer measurement software. Suitable for online measurement and secondary development. ‘# Remote Diagnosis and Technical Support Real time communication and wireless WIFI functions need to be installed. Multi-Point Measurement System * Four Channel Option Through four-channel software and an external four-channel switcher, the PM5 Gen2 can measure and display four-point thickness values at the same time. Includes four-channel real-time measurement software and secondary development library function, * Sixteen Channel Options External 16-channel switcher and host computer multi-point measurement software. Software options such as high-speed measurement, window mode, and storage are also included. Thickness Measurement of Internally Corroded Metal Materials (One of the main applications of the PMS Gen2 thickness gauge is to measure pipes, fitings, boxes, and pressure vessels that are corroded. In some special applications, the anti-corrosion layer of these materials is generally re- quired to be thicker than 4mm and some even up to 20mm. The anti-corrosion layer is not removed, the remaining thickness of the metal pipe is measured by thru-coating thickness gauge. Through Coating Technology of PM5 Gen2 Ultrasonic Thickness Gauge The through coating function of ultrasonic thickness gauge is used to measure the net substrate thickness of pipes, boxes, or other metal materials with paint or coatings on the surface. Quickly and accurately measure metal thickness without removing the coatings! This function is achieved by measuring the two continuous bottom echoes of the substrate, The thickness of penetrating coating depends on the selected probe and the material of the coating. The PMS Gen2 ultrasonic thickness gauge uses a specialized probe for penetrating thick coatings, which can accurately ‘measure metal thickness through coatings of 20mm or even thicker. It can make the detection work faster and more efficient, Boiler Tube and Inner Wall Oxide Layer Measurement (Option) PMS Gen2 measures the thickness of the oxide layer! sediment on the inner wall of boiler tubes. The thickness gauge displays both the base metal thickness and the oxide layer thickness of boiler tubes. Knowing the thickness of the oxide layer/sediment can predict the life of the tubes, When ultrasonic waves propagate from one medium to another, reflection ocours at the interface between the two media. The interval time between the reflected pulses is proportional to the material thickness. This time is converted into a thickness value, which is the thickness of the material being measured. Our PMS Gen2 thickness gauge can measure the thickness of the inner wall oxide layer of the tube with a thickness as low as about 0.25 mm when using a 15MHz delay line probe. It can display the wall thickness of the steel tube and the thickness of the inner wall oxide layer at the same time, Thickness Measurement for High Temperature or Curved Materials 410 high temperature environment measurement, temperature differences of material will affect the accuracy of ma- terial velocity and thickness measurement, For automated measurements, especially for water immersion or high temperature measurements that require measurement speed, the high temperature couplant flies instantly, and the measured value cannot be seen at all ‘¢Small-diameter metal and plastic tubes, glass lamps or glassware, and the R angle of automotive stamping is diffi cult to keep the probe perpendicular to the surface of the material being measured due to the small tube diameter, large curvature, and small contact surface, which will result in a small echo signal Temperature compensation, high-speed measurement, automatic freeze, and directional capture are all useful in these cases, Temperature Compensation Option High temperature can have an adverse effect on the inspection of pressure vessels and pipes, which affects the accuracy of material velocity and thickness measurements. In general, the sound velocity in solid decreases with the increase of medium temperature. The PMS Gen2 can compensate for changes in sound velocity caused by temperature changes. Users can manually input the temperature value of the calibration block and the actual temperature value during measurement, and the instrument automatically displays the temperature-corrected thickness value Use High Temperature Delay Line Probes The PMS Gen? uses a high temperature delay line probe. The high temperature delay line acts as a protective buffer between the surface of the sample and the probe element. The interface - echo method is used during mea- surement to avoid errors caused by temperature changes and zero drift of the delay block. The shape of the delay block (grinding arc) provides a better coupling for curved surface detection. Directional Capture Option PMS Genz has five capture modes, namely MIN, MAX, HIGHEST ECHO, MOST EQUAL and MOST ECHO. The captured waveform and thickness value can be displayed automatically or manually The waveform and value we need will be automatically captured when the set conditions are met. A white OK mark appears in the lower left corner of the screen and the waveform turns white. High Speed Measurement and Synchronous Directional Display High-speed measurement and synchronous directional display of the PMS Gen2 adjust in 16Hz steps , with a window mode of measurement rate of up to 2KHz. The measurement speed is related to alarm, capture, auto-freeze,B-Scan, real-time transmission. The screen synchronously displays the waveform and thickness values at the set update rate speed, and 8 directional display schemes can be set. Automatic Freeze Option PMS Genz can froze the waveforms and values automatically during the special measurement process. Four trigger conditions can be set, the highest wave, the number of consecutive waves, the number of echoes, and the target thickness range. When all trigger conditions are met at the same time, the waveform is automatically frozen. The automatic freeze function can be used for post-processing operations, especially for high-temperature or curved surface measurements. It is convenient to adjust parameters such as gain to obtain stable measurement Thickness Measurement of Plastics, Metal, Coated Material, Glass, Rubber and Ceramic The PMS Gen2 ultrasonic thickness gauge can measure the thickness of metals, coated materials, plastics, composites, glass, rubber, fiberglass, ceramics and other materials. We offer a variety of probes with different frequencies, diameters and interface types. When users need to measure thin metal materials with muitiple echoes, the ultra-high resolution option can provide accurate thickness measurements with a resolution of 0.0001 mm. 4 All probes have a maximum resolution of 0.001 mm, 4 High-resolution option measures display resolution up to 0.0001 millimeters Multiple measurement units: mm, inch, micron, mil ¢ Single crystal probe with frequency range from 0.5MHz to 20MHz 4 The large range option is used to measure thick metal materials or highly attenuating materials such as fiberglass and rubber. 4 The multi-layer option allows thickness measurement of each layer of a multi-layer material to be measured simultaneously. 4 The storage option can store thickness values, waveforms, parameters, etc. The required measurement data can be directly loaded during measurement, simplifying the thickness measurement operation. 4 The sound velocity can be calculated by the known sample thickness, or directly load from the sound velocity list The multi-channel option is equivalent to configure multiple ultrasonic probes on one device for thickness measurement. Thickness Measurement of Strong Acoustic Attenuation Materials Use low frequency (0.5MHz) probe to measure thicker or stronger acoustic attenuation materials such as rubber, fiberglass, castings, and composites, Large Range Option The large range option for PMS Gen2 is a composite measurement mode of pulse-echo method, the display range is up to 38 meters, and keep high precision at a large range. When measuring thick materials, the measuring range exceeds the material thickness (sound velocity 5900m/s in steel, range is 300mm), the large range option need to be selected. 0.0001mm Resolution PMS5 Gen2 instrument's high resolution option display thickness readings with resolution (I-ME mode) up to 0.0001mm, 0.1um, 0,00001in, 0.01mils. The appropriate resolution can be selected according to the material, geometry, surface conditions and temperature of the workpiece being measured Double Layer Measurement Function The double layer measurement option of the PMS Gen2 can measure and display the thickness of two layers of materials at the same time, which is like two instruments measuring at the same time, this option also include mult-scan and time-difference function. Typical applications include double layer composites and coated metallic materials. + Can measure and display the thickness of double-layer composite materials simultaneously ‘S a new structural material, metal composite materials have been widely used in various industrial fields. Regular non-destructive testing of bimet posite pipes is crucial. The most common bimetallic composites are outer layer of 20# steel and inner layer of stainless steel, Due to the similar acoustic impedance of the two materials, although the interface reflection waves can be observed, the reflection waves are weak and the interface reflection char of the measurement point are not obvious. PMS Gen2 thickness gauge can achieve accurate measurement. 20H Steel + 304 Stainless Stee! Bimetallic Material Measurement ¢ Measure the coated metal material 1en measuring the coated metal material, the PMS Gen2 instrument can measure the thickness of the coating or paint layer and the net substrate separately and display them simultaneously. When the coating thick than 0.100mm, the time difference method is useful for the measurement of such thin coating due to the inability to recognize the coating echo, Coated Metal Measurement ¢ Measure the coating thickness on non-metal materials The coating mode option of PMS Gen2 instrument includes P-E mode and coating mode for delay line probe. It can measure thin coating on wood, concrete, composite ce accurately measu ferials and other surfaces AT mode ne to be used when the user is particularly concerned about the c oating thickness, The PMS Gen2 instrument e through the zero calibration coating function ing thickness and needs tc he ables accurate measurement of the atin Coated Non-metal Measurement Mul Multi-layer measurement option calculates and displays th multaneously or displays the thickness values of 4 lay applications includ i-Layer Measurement Option thickness measurements of up to 5 different layer and the total thickness. Common multi-layer measurem nthe surface, multi-layer aircraft windshields, multi-layer I mat erials and paint layers 0 co-extruded materials, multi-layer plastic fuel tanks, etc Aircraft Windshield (Laminated Glass) Thickness Measurement Absorbing Coating Measurement Absorbing materials are also known as materials could absorb energy of electromagnetic wave that are projected on the surface, and convert the energy of electromagnetic into thermal energy or other forms of energy through dielec- tric loss of the material. They are generally composed of matrix material (adhesive) and absorbing medium (ab: bent) With the i prevention of creasing demand for invisibility of weapons and equipment, electromagneti tromagnetic wave pollution, and electronic testing, the role and statu: becoming more and more prominent. compatibility of equipment, of absorbing materials are ‘Absorbing Coating Thickness Measurement Cast Iron Spheroidization Rate Measurement The s to the fields of view, the comprehensive index of all graphite spheroidization degree, The nodularity in nodular cast iron is the key to the quality of nodular cast iron material,and itis also the focus of me- tallographic inspection. High nodularity rate means high tensile strength, high plasticity and high wear resistance. While the microscopic examination and tensile strength inspection could inspect the nodularity of cast iron effectively, ferred method is still ultrasonic testing, which could achieve rapid and non-destructive evaluation of cast iron the velocity of nodular cast iron and grey cast iron are different led nodularity, refer Experimental Data Measure Nodularity of Cast Iron by Velocity of Sound Method Multi-Channel Measurement Option, Includes Multi-Channel Measurement Software for Upper Computer Multi-channel means that a instrument is equipped with multiple ultrasonic probes and uses a multi-channel adapter to achieve measurement. Simultaneous measurement with multiple probes, and the measured echo data (thickness value, waveform, parameters, etc.) are displayed on the same screen interface. Multi-channel measurement saves costs, fast and efficient, mainly used in automatic thickness measurement. Communication interface with USB type standard, and RS232 type or RS485 type can be customized according to customer needs. srw trawew —\ ow Z Probe Lxdapier eegten Acar, L1Bee z inerace {rifle tee T 199 mal [2 Attention: Communication interface with USB standard, RS232 or R486 can be customized according to needs. Each channel has independent parameters including probe type and probe frequency setting. This case is four channels, eight channels and sixteen channels can be customized according to customer needs. Data Logger and PC Interface Storage Option The PMS Gen? thickness gauge is equipped with a builtin data recorder for convenient storage and transfer of thickness readings and waveform data, Using grid format can store 100000 thickness values and 400 waveform files with thickness values and parameter configurations. Waveform and thickness value can be mixed in the same fle, The data stored in the instrument can be imported into the computer through USB and stored in the format of EXCEL or TXT file. The instrument comes with Data View upper computer software, which can perform statistics, analysis, archiving, printing reports and other operations. cape PMS Genz grid format fle storage table uses row and column coordinates to specify locations in the grid. Rows can be marked from letters A-Z, columns can be marked from 1-21, (12 rows x 21 columns), and sequential files are numbered 0-399 (400). Loading Data in Storage Options Simplify Operation When measuring a workpiece, the operator stores the adjusted parameter configuration and measurement results inthe instrument, and the measurement data can be viewed or called at any time. When measuring again, the stored file data (including thickness value, waveform, parameters, etc.) can be directly loaded for measurement. There is no need to readjust the measurement parameters, simplifying the thickness measurement operation Real Time Communication Option ‘Can be controlled by the upper computer, the thickness value, waveform and parameters can be transmitted in real time, including upper computer measurement software. Suitable for online measurement and secondary development. Wireless Communication Configuring the Wireless Module Remote Diagnosis and Technical Support Real time communication and wireless WIF! need to be installed. Single Element Probes for Ultrasonic Thickness Measurement Contact Probe Mode! | Element Frequency cimis_| 05 | 13 1 cazsmis | 0s | 13 2.25 come | 025 | 6 5 comi3_| 05 | 13 5 ciome | 025 | 6 10 Delay Line Probe Delay line probes provide excellent measurement performance in applications where thin materials, high temperatures, or high resolution are required. Order Code P-712-0008 701-0030 -712-0008 P-712-0009 P-712-0007 Order Code (O-717-0046 (0-717-0047 > (O-717-0048 wot ERTS] rrueey Sscoilaazsiseetal aa sais tse} oe visas 028 is beens [ass | — 28 Pen Type Probe and Accessories Pen type probes feature a replaceable delay line that tapers to a very narrow contact point. These probes provide reliable thickness readings in applications such as measuring turbine blade thickness and the thickness of the fillet corner inside plastic containers. Element Size Mode! inch | mm | Frequency | Order Code . vae0-sM [0.125 | 3 15 PTt7-0011 Single Element Probes for Ultrasonic Thickness Measurement Immersion Probe Immersion probes are designed to transmit and receive ultrasonic waves in water. Thickness readings obtained by immersion techniques are generally more reliable when the geometry of the test sample is complex or when in-line inspection is performed. Typical offiine applications include wall thickness measurements on small diameter plastic ‘or metal pipes, scanning o rotational measurements, and thickness measurements on samples with large bends. ‘Some applications may require the probe to access extremely small areas. voc TEaTeTS= Truercy | _ Over cose Waa — os | as} res oman bo er un eur wate ent od was os fas) siren | tows os 6 a) errr wise ——[-o25-[ 6 | 1s | avira Note: Above immersion probe focal length can be customized according to needs Delay Line Probe Accessories Mode! Summarize Order Code Delay Probe Holder DAS | ©23°H42.6, sultabe for 6mm probe, used to measure pipe 112.0005 Delay Probe Holder D003 | 19°H140.6, sutabe for 3mm probe, used to measure pipe p112.0012 Delay 07.6912.5mm, grinding are available for 6mm size probe 112.0002 Delay ©13.9°12.5mm, grinding arc available for 13mm size probe P-112-0018 Delay {©4,7°5.5mm, suitable for Smm probe p-112.0019 High Temperature Delay PHT-13-0.5 | Suitable for 13mm probe with PMS Gen? high temperature thickness | p-112-0012 han Temperature Delay purrs | measurement software Toaszoou Cooling for one min. afte brief contact up to 480 “C High Temperature Delay PHT-13-1.5 | The probe itself cannot be heated to a temperature exceeding 60°C (122°F)| P-112-0018 ‘Suitable for 6mm probe with PMS Gen? high temperature thickness ‘measurement software High Temperature Delay PHT-6-9.5 | Cooting for one min. after brief contact up o 480 °C Pevteo019 ‘The probe itself cannot be heated to a temperature exceeding 50°C (122°F) High Temperature Delay PHT-13-1 112-0002 Single Element Probes for Ultrasonic Thickness Measurement Pen Type Probe Accessories Element Size Move! Frequency Order Code inch mm Replaceable Delay 0.080 20 oLPs Jxot64 Replaceable Delay 0.060 18 DLP-302 Jx0165 Pen Probe Holder Used with V260-SM probe P-112-0008, Immersion Probe Accessories Model Summarize Order Code Used in conjunction with Olympus V316B and V3128 probes for improved area resolution and easy access to thin-walled materials for inspection. Pee sinker _| USedin conluncton with immersion tank fr measuring workpieces that cannot Ret eens be fully immersed in water, ensuring a steady water flow and controllable flow. eee Water Spray inmersion Tank| Set eludes: transparent container, underwater pump, probe fate forse | ay with immersion probe, for incomplete immersion = The Main Technical Parameters of PMS Gen2 Measurement Principles and Parameters Measurement Mode P-E(Pulse-Echo Method): Measure the time interval between initial pulse and the first, back-wall echo, |-£(Interface Wave-Echo Method): Measure the time interval between the delay block echo and the first back-walll echo. |-E-E(Echo-Eicho Method): Measure the time interval between two consecutive back- wall echoes, I-ME(Multiple Echo Method): Measure the time interval between multiple backwall echoes. E-EV(Double Echo Verification): In E-EV mode, three echoes are required. COAT Mode(Optional): This is coating specific measurement mode. OXIDE Mode(Optional): Specially designed to measure the thickness of the oxide layer on the inner wall of boiler tube. PELR Mode(Optional): When the material thickness exceeds the measuring range, this mode needs to be selected. Probe Types ‘Supply for delay line probes, contact probes, protective film probes, pen type probes, water immersion probes and high temperature probes. Calibration Methods Zero calibration type, calibrate sound velocity, one-point calibration, two-point calibration, sel sound velocity, material sound velocity table Indication Error 40.01 Hs3mm 40.05 3

You might also like