COOLING WATER TREATMENT PROGRAMS MAXIGARD® DIESEL ENGINE WATER TREATMENT AND

LIQUIDEWTTM COOLING WATER TREATMENT ONBOARD GRAPHING LOG


VESSEL NAME: ___________________________ COMPANY NAME: ___________________________________________ VOYAGE #: ________________

MONTH: ________________ FLAG: __________________________ CHIEF ENGINEER:______________________________________________________

ENGINE TYPE: MAIN: ________________ AUX:_______________ WATER SOURCE: DISTILLED: _______________ OTHER: ______________________

YEAR: ________________ TESTED BY: _____________________________________________________________________________________________

SYSTEMS/
WATER CAPACITY

ppm Month/Date
Product CWT Titret1
48,000 4.0
42,000 3.5
36,000 3.0
MAXIGARD 30,000 2.5
treatment
Satisfactory 24,000 2.0
22,000 1.8
19,000 1.6
18,000 1.5
17,000 1.4
16,000 1.3

22,000 2.5
17,000 2.0
15,000 1.8
14,000 1.6
LIQUIDEWT 13,000 1.5
treatment
Satisfactory 12,000 1.4
11,000 1.3
10,000 1.2
9,000 1.1
8,000 1.0

Chemical
Dosage
Makeup Water
Hardness
(makeup water) ppm
Chloride
(system water) ppm

Comments:

©2009, Drew Marine. ®Registered trademark, Drew Marine.


1 CW_MAXIGARD_DIESEL_LIQUIDEWT_LS
Registered trademark, CHEMetrics, Inc.
Drew Marine

TEST RESULTS AND DOSAGE REQUIREMENTS (Control Limits in Shaded Area)


CONVERSION CHART CONVERSION CHART
MAXIGARD® LIQUIDEWTTM
Diesel Engine Water Treatment Cooling Water Treatment

SCALE MAXIGARD DOSAGE SCALE LIQUIDEWT DOSAGE


UNITS as ppm prod in liters/ton UNITS as ppm prod in liters/ton
Initial Dosage: 16.0 liters/ton Initial Dosage: 8.0 liters/ton
1.0 12,000* 6.0 1.0 8,000* 1.5
1.1 13,000 6.0 1.1 9,000 1.5
1.2 14,000 6.0 1.2 10,000 Satisfactory - no dosage
1.3 16,000 6.0 1.3 11,000 Satisfactory - no dosage
1.4 17,000 4.0 1.4 12,000 Satisfactory - no dosage
1.5 18,000 4.0 1.5 13,000 Satisfactory - no dosage
1.6 19,000 Satisfactory - no dosage 1.6 14,000 Satisfactory - no dosage
1.8 22,000 Satisfactory - no dosage 1.8 15,000 Satisfactory - no dosage
2.0 24,000 Satisfactory - no dosage 2.0 17,000 High
2.5 30,000 Satisfactory - no dosage 2.5 22,000 High
3.0 36,000 Satisfactory - no dosage 3.0 26,000 High Partially drain
3.5 42,000 Satisfactory - no dosage 3.5 30,000 High and freshen
4.0 48,000 High Partially drain 4.0 34,000 High system
5.0 60,000 High and freshen 5.0 43,000 High
7.0 84,000 High system 7.0 60,000 High
10.0 120,000 High 10.0 86,000 High
High quality distilled makeup water is recommended. High quality distilled makeup water is recommended.

*If readings are below 12,000 (scale unit 1.0), use 10.0 ltr/ton and retest. If *If readings are below 8,000 (scale unit 1.0), use 5.0 ltr/ton and retest. If system
system has been partially drained and refilled, use initial dosage. has been partially drained and refilled, use initial dosage.

The use of high quality distilled makeup water is recommended as the best means of
controlling scale formation.

REFERENCE TESTS FOR MAKEUP WATER CONTAMINANTS


Use any one of the following parameters as an indicator of makeup water contamination.

Parameter Limit

*Conductivity 500 µS/cm maximum


*Chloride-Use Sample Pretreatment Procedure at the right 100 ppm maximum
*Hardness 170 ppm maximum

*If any parameter is higher than the maximum, use better quality water.

CHLORIDE SAMPLE PRETREATMENT


Apparatus and Reagents
Chloride LMP Test Kit PCN 0373-01-9
Sample Pretreatment, 5 gm PCN 0374-01-7
(includes 0.5 gm scoop)
Filter Paper, Box of 100 PCN 0225-01-2
Funnel, Plastic PCN 0221-01-0
Stirring Rod, Plastic, 150mm PCN 0417-01-5

Procedure
1. Add one scoop (0.5 gm) Sample Pretreatment to approximately 70 ml cooling water and
stir well.
2. Let stand for two (2) minutes to allow precipitate to settle.
3. Filter the sample and proceed with the chloride determination using the Chloride LMP
Test Kit.