TEST REPORT
Work Order : TK2400691 Page : 1 of 2
Client : KHALID AL ADHAM MUTAEB AL ENAZI CO FOR TRADING AND Laboratory : ALS Arabia - Tabuk
GENERAL CONTRACTING
Contact : Mr. Abdul Mujeeb Contact : Sercan Soytas
Address : Buraidah Address : Building Number 4898, Ibrahim Al-Khalil Street, Al-Safa
Central Region district, Tabuk Tabuk Saudi Arabia 47918
E-mail : MUJEEB@KAMETC.COM E-mail : sercan.soytas@alsglobal.com
Telephone : ---- Telephone : 92007303
Facsimile : ---- Facsimile : +966 13 834 7676
Project : Water Analysis QC Level : ALS ARABIA Standard Quality Schedule (QCS3)
Order number : SA/0615/24 Date Samples Received : 29-Apr-2024 16:00
C-O-C number : ---- Date Analysis Commenced : 01-May-2024
Sampler : ---- Issue Date : 01-May-2024 15:59
Site : ---- No. of samples received : 1
Quote number : SA/0615/24 No. of samples analysed :1

This report supersedes any previous report(s) with this reference. Results apply to the sample(s) as submitted. All pages of this report have been checked and approved for
release.

Signatories
This document has been electronically signed by the authorized signatories below. Electronic signing is carried out in
compliance with procedures specified in 21 CFR Part 11.
Signatories Position Accreditation Category

Muaid Jamal Chemist Inorganic Chemistry, Tabuk

Building Number 4898, Ibrahim Al-Khalil Street, Al-Safa district, Tabuk Tabuk Saudi Arabia 47918
ALS_Arabia_COA_Version1 Tel. 92007303 Fax. +966 13 834 7676 www.alsarabia.com
Page : 2 of 2
Work Order : TK2400691
Client : KHALID AL ADHAM MUTAEB AL ENAZI CO FOR TRADING AND GENERAL CONTRACTING
Project : Water Analysis

General Comments
The analytical procedures used by the Life Sciences Division have been developed from established internationally recognized procedures such as those published by the USEPA, APHA AS, NEPM, FDA /BAM,
AOAC, ISO etc. In house developed procedures are employed in the absence of documented standards or by client request.
When sampling time information is not provided by the client, sampling dates are shown without a time component. In these instances, the time component has been assumed by the laboratory for processing purposes.

Key : LOR = Limit of reporting


l The sampling has been conducted by ALS Arabia personnel according to the sampling plan drawn up by the client.

Analytical Results
Matrix: WATER Client sample ID Ready Mix Concrete ---- ---- ---- ----
Waste Water
Sub-Matrix: WATER Client sampling date / time 28-Apr-2024 16:00 ---- ---- ---- ----

Compound CAS# LOR Unit TK2400691-001 -------- -------- -------- --------

METALS
Calcium 7440-70-2 1.0 mg/L 183 ---- ---- ---- ----
Magnesium 7439-95-4 1.0 mg/L 16.4 ---- ---- ---- ----
PHYSICAL PARAMETERS
pH Value ---- 0.01 pH Unit 12.1 ---- ---- ---- ----
Total Dissolved Solids ---- 5.0 mg/L 3740 ---- ---- ---- ----
Total Suspended Solids ---- 5.0 mg/L 511 ---- ---- ---- ----

Brief Method Summaries


The analytical procedures used by the Life Sciences Division have been developed from established internationally recognized procedures such as those published by the USEPA, APHA AS, NEPM, FDA /BAM,
AOAC, ISO etc. In house developed procedures are employed in the absence of documented standards or by client request.
Analytical Methods Site Method Matrix Method Descriptions
pH & Temperature TK NE001 WATER ISO 10523:2008: Water quality - Determination of pH
Total Dissolved Solids (TDS) TK NE002 WATER Hach Method 8163: Determination of Total Dissolved Solids by USEPA Gravimetric Method
Total Suspended Solids - Waste TK NE003 WATER APHA 2540D: Suspended Solids, Standard Methods for the Examination of Water and Wastewater
water
Metals, Calcium TK NE054 WATER Hach Method 8222: Determination of Hardness, Calcium by Titration Method with EDTA
Metals, Magnesium TK NE061 WATER Hach Method 8226: Determination of Total Hardness by Titration Method with EDTA
A `*` symbol preceding any method indicates laboratory or subcontractor non -accredited test. In the case when a procedure belonging to an accredited method was used for non -accredited matrix, would apply that