MOTOR VESSEL STANDARD BOILER WATER TREATMENT PROGRAM WITH DREWPLEX® OX CORROSION INHIBITOR ONBOARD GRAPHING LOG

Vessel Name: _____________________________ Co. Name: _______________________________Voyage #: _________________ Boiler: ___________ Flag: __________________
Month: ___________Year: __________ Chief Engineer: _________________________________________________ Tested_____________________Boiler Pressure: ____________
DATE: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Hotwell Temp C/F
Over
0.9
0.8
Daily Control 0.6
Test 0.4
DEHA 0.2
in ppm
0
DREWPLEX OX Dosage
Over
160
Daily Control 150
Test 140
Phenolphthalein130
Alkalinity 120
in ppm 110
100
Under
GCTM Dosage
Over
250
240
230
220
210
Daily Control
200
Test
Total 190
Alkalinity 180
in ppm 170
160
150
Under
Over
60
Daily Control 50
Test 40
Phosphate 30
in ppm 20
10
Under
ADJUNCT® B Dosage
Over
450
400
350
Daily Control 300
Test 250
Chloride 200
in ppm 150
100
50
0
Over
700
600
Daily Control 500
Test 400
Neutralized 300
Conductivity 200
in µS/cm 100
0
Cont. Blowdown (mins)
Bottom Blowdown (secs)
Cond. pH drops of acid
SLCC-ATM Dosage
Comments: DREWPLEX OX Continuous Feed: Yes No

©2009, Drew Marine. ®Registered trademark, TMTrademark, Drew Marine. MV_STANDARD_DREWPLEX_OX_LS


Drew Marine

Motor Vessel Standard Boiler Water Treatment Program


with DREWPLEX® OX Corrosion Inhibitor

TEST RESULTS DOSAGE PER TON CORRECTION


Sample Point: Boiler Water
PHOSPHATE (ppm): Less than 10 30 gm
10-20 15 gm ADJUNCT® B phosphate boiler
20-40 Satisfactory water treatment
More than 40 Blowdown

Sample Point: Boiler Water


P-ALKALINITY (ppm): Less than 20 0.15 liter
20-90 0.10 liter GCTM concentrated alkaline
90-100 0.05 liter liquid
100-150 Satisfactory
More than 150 Blowdown

Sample Point: Feedwater


OXYGEN SCAVENGER (ppm): Less than 0.4 Increase dosage by 25%
DREWPLEX OX 0.4 - 0.8 Satisfactory DREWPLEX OX corrosion inhibitor
corrosion inhibitor More than 0.8 Decrease dosage by 25%

Sample Point: Condenser Outlet


CONDENSATE pH: Less than 2 drops acid Increase dosage by 25% SLCC-ATM condensate
2 - 3 drops Satisfactory corrosion inhibitor
More than 3 drops acid Decrease dosage by 25%

Sample Point: Boiler Water


CHLORIDE, ppm: 0-300 Maintain normal blowdown schedule
Over 300 Increase blowdown

Sample Point: Boiler Water


NEUTRALIZED 0-700 Maintain normal blowdown schedule
CONDUCTIVITY, µS/cm Over 700 Increase blowdown

©2009, Drew Marine.


®
Registered trademark, TMTrademark, Drew Marine. MV_STANDARD_DREWPLEX_OX_LS