SHEET INDEX

SHEET TITLE
S-000 COVER SHEET
S-001 GENERAL NOTES

S-100 FOOTING & SLAB PLAN


S-101 SUB-FLOOR FRAMING PLAN
S-200 FOOTING & SLAB DETAILS - SHEET 1
S-201 FOOTING & SLAB DETAILS - SHEET 2
S-202 FOOTING & SLAB DETAILS - SHEET 3
S-203 FOOTING & SLAB DETAILS - SHEET 4
S-204 FOOTING & SLAB DETAILS - SHEET 5
S-205 FOOTING & SLAB DETAILS - SHEET 6

S-300 ROOF FRAMING PLAN


S-400 FRAMING DETAILS - SHEET 1
S-401 FRAMING DETAILS - SHEET 2
S-402 FRAMING DETAILS - SHEET 3
S-403 FRAMING DETAILS - SHEET 4

WA QLD NSW VIC


www.structerre.com.au

FOR CONSTRUCTION
SUBJECT TO APPROVAL BY THE
RELEVANT BUILDING SURVEYOR
OR STATUTORY AUTHORITY.

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES COVER SHEET LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 B.N. 23/02/22 S-000
GENERAL NOTES: FLEXIBLE CONNECTIONS (AS NECESSARY). CONCRETE WORK NOTES: THREADS MAY BE INCLUDED IN THE SHEAR PLANES U.N.O.
DURABILITY CLASSIFICATION
SH.4. FORMWORK & SCAFFOLDING
D.9. ADDITIONAL PLUMBING REQUIREMENTS ARE NEEDED FOR MODERATELY, HIGHLY C.1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 3600 & ALL BOLTS, NUTS AND WASHERS SHALL BE HOT DIP GALVANISED. CLIMBING ON SCAFFOLDING OR FORMWORK AND WORKING AT HEIGHTS WITHOUT
G.1. IT IS THE RESPONSIBILITY OF THE CLIENT IN CONSULTATION WITH THEIR BUILDER
& EXTREMELY REACTIVE SITES IN ACCORDANCE WITH CLAUSE 6.6 FROM AS 2870. AS 2870. U.N.O BOLTS DENOTED 4.6/S ARE COMMERCIAL BOLTS OF STRENGTH GRADE 4.6 TO AS CATEGORY WALL TIES GRADE OF BRICKS *MORTAR SUITABLY APPROVED RAILINGS, BARRIERS AND RESTRAINTS FIXED TO
TO CHECK AND VERIFY THE BUILDABILITY OF THE DESIGN AS PRESENTED AND
1111 SNUG TIGHT. (DURABILITY) AS 3700 AS/NZ 4456.10 AS 3700 UNCERTIFIED ANCHOR POINTS IS STRICTLY PROHIBITED. ALL FORMWORK AND
REFER ANY CONCERNS BACK TO THE ENGINEER PRIOR TO CONSTRUCTION. THESE D.10. PLUMBING & DRAINAGE UNDER THE SLAB SHOULD BE AVOIDED WHERE C.2. CONCRETE QUALITY FOR CEMENT TYPE A & EXPOSURE CLASSIFICATION A1 SHALL BOLTS DENOTED 8.8/S, 8.8/TB AND 8.8/TF ARE HIGH STRENGTH STRUCTURAL SCAFFOLDING SYSTEMS ARE TO BE DESIGNED AND CERTIFIED BY A LICENSED
DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE PROJECT ARCHITECTURAL PRACTICAL. REFER AS 2870 CLAUSE 5.6.4 (d). BE AS TABULATED AND SHALL BE VERIFIED BY TESTS (REFER TABLE BELOW). SEVERE R4 (STAINLESS
BOLTS OF STRENGTH GRADE 8.8 TO AS/NZS 1252 & AS/NZS 4291.1. EXPOSURE M4 (1:4) CONTRACTOR TO COMPLY WITH RELEVANT AUSTRALIAN STANDARDS AND KEPT
AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS IT IS ASSUMED THAT U.N.O, SEE SLAB PLAN FOR A2, B & C CATEGORIES. MARINE OR POLYMER)
D.11. ALL PIPEWORK INCLUDING STORMWATER FITTINGS & ADAPTERS SHOULD BE 8.8/S DENOTES BOLTS SNUG TIGHT. MAINTAINED IN GOOD WORKING ORDER.
THE USER OF THESE DETAILS HAS A LEVEL OF FAMILIARITY AND COMPETENCY TO
PROTECTED FROM MECHANICAL DAMAGE. CONCRETE 8.8/TB DENOTES BOLTS FULLY TENSIONED IN BEARING, TO AS 4100. MARINE R3 GENERAL PURPOSE M3 (1:1:6)
UNDERSTAND AND EXECUTE THE WORKS. PLEASE CONTACT THIS OFFICE FOR ELEMENT SLUMP AGG COVER U.N.O (mm) SH.5. EXCAVATION
GRADE 8.8/TF DENOTES BOLTS FULLY TENSIONED IN FRICTION, TO AS 4100 - MATING EXTERIOR R2 GENERAL PURPOSE M2 (1:2:8)
FURTHER ADVICE IF REQUIRED. D.12. PROVISIONS SHOULD BE MADE FOR THE CONNECTION OF OVERFLOW OR WATER
20 TOP SURFACES MUST NOT BE PAINTED. * NOMINAL MORTAR THICKNESS TO BE 10mm. THE BUILDER SHALL PROVIDE SUITABLE FENCING AROUND ALL EXCAVATIONS
G.2. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL & DISCHARGE FROM FIXTURES SUCH AS HOT WATER SYSTEMS & AIR CONDITIONERS
TO THE LEGAL POINT OF DISCHARGE (LPoD) SLABS ON
100mm 20mm 20N 30 BTM. & SIDES S.9. BOLTED STEEL TO STEEL CONNECTIONS MAY BE SUBSTITUTED WITH 6mm CFW AND AT NO STAGE SHOULD AN EXCAVATION BE APPROACHED OR ENTERED INTO
OTHER CONSULTANTS DRAWINGS & SPECIFICATIONS & WITH SUCH OTHER GROUND UNLESS AN APPROVED AND CERTIFIED SHORING SYSTEM HAS BEEN INSTALLED
40 TOP (EXT.) WELDED CONNECTIONS (ALL AROUND). F.S.B.W WHERE SPECIFIED SHALL BE TIMBER NOTES:
WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF THE D.13. STORMWATER SYSTEMS THAT COLLECT ROOF WATER & SURFACE WATER ARE OR THE BANKS HAVE BEEN BATTERED AND/OR BENCHED IN ACCORDANCE WITH
MAINTAINED.
CONTRACT. ALL DISCREPANCIES SHALL BE REFERRED TO THE REQUIRED TO BE DESIGNED & CONSTRUCTED IN ACCORDANCE WITH AS/NZS 3500 FOOTINGS 100mm 20mm 20N 50 TYPICAL T.1. ALL EXTERNAL TIMBER MEMBERS ARE TO BE WEATHER TREATED. THE PROJECTS GEOTECHNICAL ENGINEERING SPECIFICATION AND/OR WRITTEN
ARCHITECT/ENGINEER FOR DECISION BEFORE PROCEEDING WITH THE WORK. PART 5. 30 TOP S.10. ALL DETAILS, GAUGE LINES ETC. (WHERE NOT SPECIFICALLY SHOWN) ARE TO BE IN MANUFACTURED TIMBER ELEMENTS (e.g. LVL) EXPOSED TO WEATHERING SHALL INSTRUCTIONS BY THE INSPECTING GEOTECHNICAL ENGINEER. THE BUILDER
SUSPENDED SLAB 80mm 20mm 32N ACCORDANCE WITH AISC PUBLICATIONS "DESIGN CAPACITY TABLES FOR BE L.O.S.P. TREATED TO H3 LEVEL. WHERE EXPOSED TO DIRECT SUN, FURTHER SHALL SUPPORT OR PROP ANY EXISTING STRUCTURES WITHIN THE ZONE OF
G.3. THESE DRAWINGS ARE COPYRIGHT TO STRUCTERRE CONSULTING AND MAY NOT PROPERTY MAINTENANCE NOTES: 20 BTM. & SIDES
STRUCTURAL STEEL" AND "STANDARDISED STRUCTURAL CONNECTIONS". PLATES
BE USED IN WHOLE OR IN PART WITHOUT WRITTEN OR FORMAL PERMISSION PROTECTION WITH A GOOD QUALITY PAINT SYSTEM IS REQUIRED. INFLUENCE OF ALL EXCAVATIONS AND IS RESPONSIBLE FOR MAINTAINING THIS
P.1. APPENDIX A OF AS 2870 DEFINES THE OWNER AS THE PERSON OR ORGANISATION BEAMS 80mm 20mm 32N 45 TYPICAL ARE TO BE 10mm THICK, CUT FROM STANDARD FLAT BARS U.N.O. ENDS OF
FROM STRUCTERRE CONSULTING T.2. ALL WORK IN STRUCTURAL TIMBER TO BE IN ACCORDANCE WITH THE CURRENT SUPPORT THE THROUGH THE CONSTRUCTION PROCESS.
RESPONSIBLE FOR THE MAINTENANCE OF THE BUILDING & THE SITE. 45 TOP HOLLOW SECTIONS SHALL BE SEALED WITH NOMINAL THICKNESS PLATES AND
G.4. DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE STRUCTURAL DRAWINGS. STAIRS 80mm 20mm 32N
CONTINUOUSLY WELDED TO SEAL ENDS, UNO. EDITION OF AS 1684, SAA TIMBER FRAMING CODE AS 1720, SAA TIMBER SH.6. SITE HAZARDS & RISKS
P.2. THE OWNER'S ATTENTION IS DRAWN TO APPENDIX B 'PERFORMANCE CRITERIA & 35 BTM.
ALL DIMENSIONS SHOWN ARE MILLIMETRES U.N.O. ENGINEERING CODE AS 1320 - GLUED LAMINATED STRUCTURAL TIMBER.
FOUNDATION MAINTENANCE' & APPENDIX C 'CLASSIFICATION OF DAMAGE DUE TO 30 SIDES (INT.) S.11. CORROSION PROTECTION. IT IS THE CLIENT'S AND THE BUILDER'S RESPONSIBILITY TO MAKE THE DESIGNER
G.5. SETTING OUT DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY FOUNDATION MOVEMENTS' OF AS 2870-2011. WALLS 80mm 20mm 32N T.3. TIMBER MEMBERS PARALLEL TO MASONRY WALLS SHALL BE SEPARATED FROM AWARE OF ANY INFORMATION RELATING TO HAZARDS AND RISKS WHERE
40 SIDES (EXT.) S.11.1. INTERNAL STEELWORK (ENCLOSED)
THE BUILDER. THE MASONRY WITH A GAP OR WATERPROOF MEMBRANE CONSTRUCTION WORK IS CARRIED OUT, INCLUDING BUT NOT LIMITED TO THE
P.3. AS PER CLAUSE 1.3.1 BUILDINGS DESIGNED & CONSTRUCTED TO AS 2870 ON A COLUMN 80mm 20mm 32N 40 TYPICAL S.11.2. THE STEELWORK SHALL BE CLEANED TO AS 1627 CLASS 1 AND GIVEN ONE LOCATION OF UNDER GROUND AND ABOVE GROUND SERVICES, IDENTIFICATION
G.6. DURING CONSTRUCTION THE STRUCTURE SHALL BE MAINTAINED IN A STABLE NORMAL SITE DOES NOT GUARANTEE A DISTRESS FREE DWELLING. BUILDINGS T.4. TIMBER MEMBER SUPPORTED BY TIMBER POST OR BRICKWORK SHALL HAVE 5mm
COAT OF ALKYD PRIMER TO GIVE A DRY FILM THICKNESS OF 50 MICRONS MIN. CLEARANCE FROM SURROUNDING BRICKWORK AT TOP & SIDES. DO NOT FILL OF CONTAMINATED SOILS AND OTHER MATERIALS OR THE PRESENCE OF
CONDITION & NO PART SHALL BE OVERSTRESSED. ARE EXPECTED TO EXPERIENCE EITHER NO DAMAGE, A LOW INCIDENCE OF C.3. SAMPLE AND TEST IN ACCORDANCE WITH AS 3600. BEFORE DISPATCH TO SITE, UNLESS THE STEEL IS TO BE ENCASED IN GAP WITH MORTAR. FLASH SECURELY TO PREVENT INGRESS OF WATER. DANGEROUS MATERIAL INCLUDING ASBESTOS. DURING THE CONSTRUCTION, THE
G.7. ALL WORKMANSHIP & MATERIALS SHALL BE IN ACCORDANCE WITH THE DAMAGE CATEGORY 1 & OCCASIONAL INCIDENCE OF DAMAGE CATEGORY 2 AS C.4. CONSOLIDATE BY VIBRATION. CONCRETE OR IS DETAILED OTHERWISE. APPLY ONE FINISH COAT OF ALL BUILDER SHALL PROTECT NEIGHBOURING PROPERTIES FROM NOISE IN
REQUIREMENTS OF THE CURRENT EDITIONS OF THE AS CODES & THE BY-LAWS & SHOWN IN TABLE BELOW. WEATHER GLOSS ACRYLIC PAINT. T.5. ALL MULTIPLE SAWN MEMBERS TO BE NAIL LAMINATED IN ACCORDANCE WITH ACCORDANCE WITH THE LOCAL AUTHORITY REQUIREMENTS, RADIATION, GROUND
C.5. THOROUGHLY SCABBLE CONCRETE ON WHICH NEW CONCRETE IS TO BE POURED. REQUIREMENTS OF AS 1684. FOR MULTIPLE LVL MEMBERS REFER TO
ORDINANCES OF THE RELEVANT BUILDING STATE AUTHORITY. VIBRATIONS AND OTHER CONSTRUCTION HAZARDS. CONDITION REPORTS ON
SUMMARY OF AS2870-2011 - APPENDIX C TABLES C1 & C2 C.6. ALL CONCRETE SHALL BE PLACED AND CURED IN ACCORDANCE WITH AS3600. S.11.3. EXTERNAL STEELWORK (UNENCLOSED) MANUFACTURER'S SPECIFICATIONS.
G.8. THIS REPORT IS BASED ON INFORMATION SUPPLIED BY THE CLIENT. IF ANY THE NEIGHBOURING PROPERTIES AND STRUCTURES ARE RECOMMENDED PRIOR
DAMAGE LEVEL CHANGES WHERE CURING COMPOUNDS ARE USED IT MUST BE APPLIED AS FOLLOWS: S.11.4. ALL STRUCTURAL STEELWORK WHICH IS EXPOSED OR IN CONTACT WITH T.6. BOLTS: ALL NUTS & BOLTS TO BE PROVIDED WITH WASHERS. ALL BOLTS TO BE TO CONSTRUCTION.
ASPECT OF THE SITE PREPARATION OR PROPOSED CONSTRUCTION CHANGES WALL CRACKS SLAB CRACKS
CATERORIES OVER 3m C.6.2. ONTO SLAB WITHIN 2HRS OF FINISHING OPERATION. EXPOSED BRICKWORK, AND ALL LINTELS, SHALL BE HOT DIP GALVANISED TIGHTENED FINALLY BEFORE HANDOVER. BOLT HOLES TO BE 2mm OVERSIZE IN
FROM THAT ORIGINALLY ADVISED, THE ENGINEER MUST BE NOTIFIED SO THAT SH.7. BOUNDARY & SERVICES
0 - Negligible < 0.1mm < 0.3mm < 8mm AFTER FABRICATION. STEELWORK GALVANISED AFTER FABRICATION SHALL UNSEASONED TIMBER.
ANY NECESSARY AMENDMENTS CAN BE MADE. C.6.3. ONTO WALLS AND COLUMNS IMMEDIATELY AFTER REMOVAL OF FORMWORK.
1- Very Slight < 1mm < 1mm < 10mm COMPLY WITH AS/NZS 4680. THE BUILDER IS REQUIRED TO VERIFY AND IF NECESSARY CONDUCT FURTHER
G.9. BUILDING PERMIT - FOR WORK REQUIRING BUILDING APPROVAL, A COPY OF THE T.7. UNLESS DETAILED OTHERWISE TIMBER MEMBERS TO BE FIXED WITH NOMINAL SEARCHES TO ACCURATELY LOCATE EASEMENTS, UNDER GROUND AND ABOVE
C.7. SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED S.11.5. AS AN ALTERNATIVE TO GALVANISING, ALL STRUCTURAL STEELWORK WHICH
BUILDING PERMIT (ISSUED BY COUNCIL OR PRIVATE BUILDING SURVEYOR) MUST 2 - Slight < 5mm < 2mm < 15mm NAILING AS SPECIFIED IN AS 1684. ALL TIE DOWN OF ROOF MEMBERS (INCLUDING GROUND SERVICES, PROPERTY BOUNDARIES, TREES, EXISTING STRUCTURES AND
FINISHES. IS EXPOSED SHALL BE CLEANED TO AS 1627 CLASS 2 1/2 PREPARATION AND
BE FORWARDED TO STRUCTERRE PRIOR TO ARRANGING ANY INSPECTIONS WITH 3 - Moderate 5mm to 15mm 2mm to 4mm 15mm to 25mm LINTELS) IN ACCORDANCE WITH AS 1684. OTHER OBSTRUCTIONS PRIOR TO CONSTRUCTION. THE DESIGNER IS TO BE
THIS OFFICE. C.8. CONSTRUCTION JOINTS WHERE NOT SHOWN SHALL BE TO THE APPROVAL OF THE GIVEN A COAT OF INORGANIC ZINC SILICATE TO GIVE A DRY FILM THICKNESS OF
4 - Severe 15mm to 25mm 4mm to 10mm > 25mm
75 MICRONS BEFORE DISPATCH TO THE SITE, UNLESS THE STEEL IS TO BE T.8. SIZES AND DETAILS NOT SHOWN SHALL COMPLY WITH AS 1684. IMMEDIATELY NOTIFIED OF ANY ELEMENTS NOT SHOWN ON THE
ENGINEER.
G.10. THE ENGINEER'S APPROVAL SHALL BE SOUGHT PRIOR TO MAKING ANY ENCASED IN CONCRETE OR IS DETAILED OTHERWISE. ALL OPENINGS TO BE FULLY FLASHED. APPROVED DRAWINGS AS THE DESIGN AND SAFETY IN DESIGN REPORT MAY
SUBSTITUTIONS. P.4. THIS DESIGN IS BASED UPON THE NORMAL FOOTING PERFORMANCE CRITERIA C.9. BEAM DEPTHS ARE WRITTEN FIRST AND INCLUDE SLAB THICKNESS, IF ANY. REQUIRE AMENDING.
PROVIDED IN TABLE 2.2 OF AS2870-2011 WITH DAMAGE CATEGORIES DETAILED IN S.11.6. REPAIR OF GALVANISED COATING AFTER WELDING PREPARATION - REMOVE T.9. ALL BOLTS TO HAVE MILD STEEL GALVANISED WASHERS :
C.10. CONCRETE SHALL BE KEPT FREE OF SUPPORTING BRICKWORK WITH 2 LAYERS OF BOLTS UP TO 12mm DIA - 50x50x3 WASHERS (or 55 DIA. x 3) SH.8. TRAINED AND QUALIFIED WORKERS
SITE CLASSIFICATION NOTES: APPENDIX C. IF THESE PERFORMANCE CRITERIA ARE UNSUITABLE FOR THIS MALTHOID. HORIZONTAL FORMWORK SHALL BE STRIPPED WHEN APPROVED BY
ALL WELDING SCALE, SLAG & SHARP EDGES. POWER TOOL CLEAN TO AS 1627.2,
DWELLING PLEASE CONSULT THIS OFFICE FOR ADDITIONAL ENGINEERING ADVICE CLASS 3, USING ABRASIVE WHEEL ON A POLISHER AT 3500RPM. DEGREASE & BOLTS UP TO 16mm DIA - 57x57x4 WASHERS (or 65 DIA. x 4) THE BUILDER IS REQUIRED TO ENSURE THAT THE SITE WORKERS ARE SUITABLY
C.1. THIS DESIGN HAS BEEN BASED UPON INFORMATION PROVIDED TO OUR OFFICE THE ENGINEER. BOLTS UP TO 20mm DIA - 65x65x5 WASHERS (or 75 DIA. x 5)
&/OR GATHERED BY OUR STAFF. & DESIGN SERVICES. REMOVE ALL SURFACE CONTAMINANTS TO AS 1627.1. QUALIFIED, TRAINED AND INSURED FOR THE TASKS BEING PERFORMED ON SITE.
C.11. SLABS ON GROUND SHALL BE PROVIDED WITH A VAPOUR BARRIER IN T.10. WHERE TERMITE PROTECTION IS REQUIRED, INSTALL IN ACCORDANCE WITH
C.2. THIS DESIGN HAS BEEN PREPARED IN ACCORDANCE WITH AS 2870 & RELEVANT P.5. THE LONG TERM PERFORMANCE OF THE FOOTINGS AS DESIGNED IS DEPENDANT S.11.7. 'SEVERE' CORROSION ENVIRONMENT - APPLY 2 COATS OF 2-PACK EPOXY ZINC SH.9. SITE MAINTENANCE
ACCORDANCE WITH AS 2870 U.N.O. AS3660. BUILDER SHALL CONFIRM WITH OWNER THE PREFERRED METHOD OF
STATE LEGISLATION. ON THE ONGOING SITE MAINTENANCE BY OWNER INCLUDING FACTORS SUCH AS TO AS 3750.9, TO TOTAL 150um DFT, FOLLOWED BY 2 PACK EPOXY ENAMEL TO IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT THE SITE IS MAINTAINED
SITE DRAINAGE, VEGETATION & WATERING OF AREAS ADJACENT TO THE C.12. U.N.O NO ALLOWANCE HAS BEEN MADE FOR STACKED MATERIALS OR MACHINERY TOTAL 150um DFT. TERMITE MANAGEMENT. OWNER IS RESPONSIBLE FOR ONGOING INSPECTION OF
C.3. SHOULD SOIL CONDITIONS ENCOUNTERED ON SITE DIFFER SIGNIFICANTLY FROM STRUCTURAL ELEMENTS & ENSURING THAT TERMITE MANAGEMENT SYSTEMS ARE IN A SAFE WORKING MANNER AND THAT ALL SITE PRACTICES ARE IN ACCORDANCE
DWELLING. ON THE CONCRETE STRUCTURE.
THOSE INDICATED IN THE SOIL TEST NOTED IN THIS DESIGN, THE ENGINEER MUST S.11.8. 'MODERATE' CORROSION ENVIRONMENT - APPLY A TOTAL OF 125um DFT OF NOT BREACHED. WITH THE CURRENT WORK PLACE HEALTH AND SAFETY LAWS AND REGULATIONS.
P.6. WATERING OF LAWNS & GARDENS SHOULD BE CONSISTENT. OVER WATERING CAN C.13. NO HOLES OR CHASES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DULUX METALSHIELD COLD GALV. PRIMER OR EQUIV IN 2 COATS, USING
BE NOTIFIED BEFORE PROCEEDING AS THE SITE CLASSIFICATION MAY NEED
DRAWINGS SHALL BE MADE IN CONCRETE ELEMENTS WITHOUT THE PRIOR BRUSH OR SPRAY CAN. T.11. ALL BEAMS, LINTELS, ROOF MEMBERS NOTED ON THIS PLAN (INCLUDING GIRDER PROCEDURE OR TASK DEVIATIONS:
REVISING & MODIFICATIONS TO THE DESIGN MAY BE REQUIRED. DAMAGE FOOTINGS. EQUALLY FOOTINGS MAY BE DAMAGED BY PROLONGED
PERIODS OF NEGLECT AFTER YEARS OF CAREFUL WATERING. LEAKING TAPS & APPROVAL OF THE ENGINEER. TRUSSES TO HAVE 2/90x45 MGP10 STUD SUPPORT (TYPICAL) UNLESS NOTED PT.1. ONSITE VARIATIONS
C.4. THE SITE INVESTIGATION MAY BE RENDERED IRRELEVANT IF THE LOCATION OF S.12. UNLESS NOTED OTHERWISE, PROTECTIVE COATINGS FOR STEELWORK SHALL BE OTHERWISE. IT IS THE BUILDER'S RESPONSIBILITY TO STRICTLY BUILD IN ACCORDANCE WITH
PIPES & BLOCKED DRAINS & GUTTERS SHOULD BE REPAIRED PROMPTLY. C.14. REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY, IT IS NOT NECESSARILY AS TABULATED BELOW AND IN ACCORDANCE WITH VOL. 2 PART 3.4.4 OF THE NCC.
PROPOSED STRUCTURES VARY FROM THAT SPECIFIED AT THE TIME OF THIS PROLONGED NEGLECT CAN LEAD TO DAMAGED FOOTINGS. T12. SMARTFRAME LVL15, HYSPAN+ (F17 GRADED LVL) or E-BEAM+ [F17] MAY BE THE DOCUMENTATION AND NOT TO MAKE ANY VARIATIONS TO THE
SHOWN IN TRUE PROJECTION. CONSTRUCTION WITHOUT THE SPECIFIC WRITTEN APPROVAL FROM THE
DESIGN. THIS DESIGN RELATES TO THE CONDITIONS EXISTING ON THE LAND AT ARTICULATED MASONRY NOTES: USED AS AN ALTERNATIVE TO F17 KDHW.
THE TIME OF THE SITE INVESTIGATION. THIS DESIGN IS BASED UPON THE P.7. TREES/ SHRUBS PROVIDED AS PART OF ANY PROPOSED LANDSCAPING SHALL BE C.15. SPLICES IN REINFORCEMENT MADE IN POSITIONS OTHER THAN SHOWN SHALL BE ENGINEER.
PROPOSED CUT / FILL INFORMATION PROVIDED BY THE CLIENT. ANY UNADVISED PLANTED A MIN. DISTANCE AWAY FROM THE FOOTINGS EQUAL TO THE MATURE TO THE APPROVAL OF THE ENGINEER. WHERE THE LAP LENGTH IS NOT SHOWN IT A.1. THIS DESIGN ASSUMES THAT MASONRY ARTICULATION JOINTS WILL BE T.13. E-BEAM+ [F17] MAY BE USED AS AN ALTERNATIVE TO HYSPAN+ (F17 GRADED
HEIGHT OF THE TREE/SHRUB. THE PROVISION OF NON-NATIVE SPECIES PLANTED INSTALLED TO AS 4773 UNLESS NOTED OTHERWISE. ANY MASONRY LVL) PT.2. COMPLIANCE INSPECTIONS
EXTENSIVE CUTTING OR FILLING MAY RENDER THIS DESIGN IRRELEVANT. SHALL BE SUFFICIENT TO DEVELOP THE FULL STRENGTH OF THE REINFORCEMENT. THIS DESIGN HAS BEEN DOCUMENTED IN ACCORDANCE WITH RELEVANT
AS SINGLE TREES/SHRUBS RATHER THAN IN GROUPINGS IS HIGHLY ARTICULATION JOINTS SHALL BE POSITIONED IN ACCORDANCE WITH AS 4773 & AS
C.5. WHILE A REASONABLE EFFORT IS MADE TO ASSESS THE SITE'S SUITABILITY FOR C.16. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED UNLESS SHOWN ON THE 3700 SECTION 12.16.4 AND AS FOLLOWS; T.14. EQUIVALENT SMARTFRAME LVL 15 or E-BEAM MAY BE USED AS AN ALTERNATIVE AUSTRALIAN STANDARDS, LOCAL AUTHORITY REGULATIONS AND STANDARD
RECOMMENDED. TO HYSPAN.
THE PROPOSED CONSTRUCTION, THIS DESIGN DOES NOT TAKE INTO ACCOUNT STRUCTURAL DRAWINGS. BUILDING CODES OF PRACTICE UNLESS NOTED OTHERWISE. EACH LEVEL OF
P.8. IT IS HIGHLY RECOMMENDED THAT CONCRETE PAVING BE INSTALLED AROUND A.1.1. MAXIMUM JOINT SPACING = 5.0m U.N.O CONSTRUCTION IS TO BE STRUCTURALLY COMPLETED AND INSPECTED TO ENSURE
SLOPE STABILITY. IF REQUIRED BY THE COUNCIL, A SUITABLY QUALIFIED PERSON C.17. PIPES OR CONDUITS SHALL NOT BE PLACED WITHIN THE CONCRETE COVER TO : SETON SSURT FOOR
SHOULD BE ENGAGED TO UNDERTAKE A SLOPE STABILITY ASSESSMENT. THE ENTIRE PERIMETER OF THE DWELLING. ALL CONCRETE PATHS & THE GROUND A.1.2. WITHIN 2.0m - 4.5m OF EXTERNAL CORNERS DESIGN COMPLIANCE BY CERTIFYING AUTHORITY PRIOR TO ADVANCING TO NEXT
ON WHICH THEY ARE LAID SHALL SLOPE AWAY FROM THE BUILDING & BE REINFORCEMENT WITHOUT THE APPROVAL OF THE ENGINEER. RT.1. THE BASIS OF DESIGN SHALL BE SAA LOADING CODE
A.1.3. CHANGES OF WALL HEIGHT & MASONRY WALL THICKNESS STAGE OF WORK. THE BUILDER SHOULD ENSURE THAT THE WORKS ARE
MISCELLANEOUS NOTES: DRAINED. DRAINAGE IN THE FORM OF SPOON DRAINS &/OR PITS, CONNECTED TO C.18. ALL REINFORCING BARS SHALL COMPLY WITH AS 4671. ALL FABRIC SHALL AS 1170.1; AS 1170.2 & SAA TIMBER STRUCTURE CODE AS 1720.1. PROGRAMMED IN A SAFE MANNER AND TO HIGHLIGHT TO THE DESIGNER ANY
M.1. AREA BETWEEN SWIMMING POOL AND DWELLING TO BE PAVED WITH CONCRETE THE LEGAL POINT OF ARATED FROM STRUCTURES WITH A 10mm LAYER OF COMPLY WITH AS 4671 AND SHALL BE SUPPLIED IN FLAT SHEETS. A.1.4. JUNCTION OF DIFFERENT MASONRY MATERIALS RT.2. DESIGN THE ROOF TRUSSES AS PER THE WIND CLASSIFICATION AS SPECIFIED. ASPECTS OF THE WORK THAT MAY REQUIRE FURTHER CLARIFICATION OR ADVICE
AND GRADED TO ENSURE ALL WATER IS DIRECTED VIA SECURE CONNECTIONS TO "ABLEFLEX" OR SIMILAR. C.19. REINFORCEMENT SYMBOLS: A.1.5. WHERE OLD BRICKWORK MEETS NEW BRICKWORK WITH REGARD TO THE HEALTH AND THE SAFETY OF THE PROJECT.
THE LEGAL POINT OF DISCHARGE (LPoD). ALL JOINTS BETWEEN PAVING, POOL RT.3. ALL TRUSS SUPPORTS BY OTHERS U.N.O. INTERNAL LOAD BEARING WALLS TO
P.9. WHERE SEAL COATS HAVE BEEN APPLIED TO EXTERNAL SLABS WITHIN 1km OF N - DENOTES GRADE D500 HIGH STRENGTH DEFORMED BARS TO AS 4671. A.1.6. ABOVE JOINTS IN FOOTINGS & SLABS & SLIP JOINT LOCATIONS HAVE STUDS LOCATED DIRECTLY BELOW EACH TRUSS. PT.3. TEMPORARY SUPPORT & BRACING
AND DWELLING TO BE MADE WATER TIGHT. ALL BRICKWORK WITHIN SPLASH SALT WATER, THE CONDITION OF THE SEALANT IS TO BE MONITORED & R - DENOTES GRADE R250 HOT ROLLED PLAIN BARS TO AS 4671.
ZONE OF POOL TO BE SEALED TO STOP INGRESS OF WATER. REFER TO BUILDING MAINTAINED THROUGH THE LIFE OF THE SLAB. SL - DENOTES HARD-DRAWN WIRE SQUARE REINFORCING FABRIC TO AS 4671. A.1.7. ABOVE JUNCTION OF STRIP FOOTINGS TO SLABS RT.4. IN ADDITION TO THE NOMINATED PERMANENT BRACING, PROVIDE ANY ALL ASPECTS DETAILED IN THE STRUCTURAL DOCUMENTS ARE THOSE REQUIRED
CONTRACTOR FOR PRODUCT. RL - DENOTES HARD-DRAWN WIRE RECTANGULAR REINFORCING MESH TO AS ADDITIONAL PERMANENT BRACING REQUIRED FOR STRUCTURAL SUFFICIENCY OF FOR THE COMPLETED STRUCTURE ONLY. THE BUILDER IS RESPONSIBLE FOR
P.10. WE ALSO DIRECT THE OWNER TO THE CSIRO PUBLICATION BTF 18 'FOUNDATION A.1.8. FOR MASONRY WALLS OVER 3.0m HIGH, REFER ENGINEER.
4671. THE TRUSS SYSTEM. PROVIDING ANY NECESSARY TEMPORARY CONNECTIONS AS WELL AS SUPPORTS
M.2. SUITABLE QUARRY PRODUCT (20-80mm MAX IN DEPTH) MAY BE USED AS A MAINTENANCE & FOOTING PERFORMANCE: A HOMEOWNER'S GUIDE'. COPIES OF A.2. WHERE MASONRY ARTICULATION IS SHOWN BESIDE OPENINGS, THE JOINT IS TO AND BRACING TO MAINTAIN THE STABILITY AND SAFETY OF THE STRUCTURE
L - DENOTES HARD-DRAWN WIRE TRENCH MESH TO AS 4671.
LEVELLING/BEDDING LAYER TO LEVEL THE BUILDING PLATFORM PRIOR TO SLAB THIS PUBLICATION ARE AVAILABLE FROM CSIRO PUBLISHING ON PH:
THE NUMBER IMMEDIATELY FOLLOWING THESE SYMBOLS IS THE BAR DIAMETER CONTINUE BETWEEN THE WINDOW/DOOR FRAME & THE BRICKWORK TO THE FULL RT.5. PROVIDE ANY TEMPORARY BRACING REQUIRED TO MAINTAIN THE STABILITY OF THROUGHOUT THE CONSTRUCTION PERIOD. THIS INCLUDES ELEMENTS SUCH AS
CONSTRUCTION. THE BEDDING LAYER SHALL BE COMPACTED TO THE 1300-788-000 OR AT http://www.publish.csiro.au/pid/7076.htm. THIS REPORT MAY HEIGHT OF THE WALL. AT THESE LOCATIONS, THE FRAMES ARE TO BE FIXED WITH THE TRUSSES AT ALL STAGES OF ERECTION. PREFABRICATED TIMBER AND STEEL ELEMENTS, UNRESTRAINED WALLS,
SATISFACTION OF THE BUILDING INSPECTOR. IN MILLIMETRES.
BE RENDERED INVALID IF THE PROPERTY IS NOT MAINTAINED AS RECOMMENDED FASTENERS THAT WILL ALLOW MOVEMENT OF THE JOINT. RT.6. MAKE ALLOWANCES FOR SIZE AND LOCATION OF MECHANICAL CONCRETE COLUMNS, BEAMS & SLABS, PRECAST PANELS, ETC., WHICH REQUIRE
M.3. UNDER NO CIRCUMSTANCE IS ANYTHING (INCLUDING BASKETBALL HOOPS) TO BE IN THIS PUBLICATION. C.20. FABRIC/MESH REINFORCEMENT TO BE LAPPED ONE MESH PLUS 30mm. LAPS IN SERVICES/AIRCONDITIONING DUCTWORK IF APPLICABLE. TEMPORARY SUPPORT OR PROPPING TO PREVENT OVER STRESS, EXCESSIVE
POSITIONS OF MAXIMUM MOMENT ARE NOT PERMITTED. A.3. WHERE MASONRY ARTICULATION IS SHOWN BESIDE OPENINGS WITH BRICKWORK
FIXED TO THE WALL ABOVE LINTELS. OWNERS TO BE NOTIFIED IN WRITING. FOUNDATIONS & FOOTINGS NOTES: ABOVE THE OPENING, CARE SHOULD BE TAKEN TO PROVIDE A SLIP JOINT RT.7. SPAN TRUSSES ONLY BETWEEN THE NOMINATED SUPPORTS AND HOLDING DOWN DEFORMATION OR INSTABILITY UNTIL THE FINAL STRUCTURAL SYSTEM IS
M.4. WHERE LARGE AREAS OF BRITTLE FLOOR COVERINGS ARE SPECIFIED IN THE C.21. ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED ON INSULATED STEEL, AROUND THE END OF THE LINTEL. POSITIONS INDICATED. COMPLETED. THE DESIGNER IS TO BE CONTACTED FOR FURTHER ADVICE IF
F.1. FOOTINGS SHALL BE PLACED CENTRALLY UNDER WALLS & COLUMNS UNLESS REQUIRED.
RESIDENCE. IN ACCORDANCE WITH AS 2870-2011 CLAUSE 5.3.7 AN APPROPRIATE PLASTIC OR CONCRETE CHAIRS GENERALLY AT NOT GREATER THAN 800 CENTRES
OTHERWISE NOTED. A.4. TO ENSURE FULL COMPLIANCE WITH AS 4773 & LOCAL REQUIREMENTS (I.E. QBCC RT.8. LOCATION & LOAD OF GIRDER TRUSSES ARE ASSUMED - TRUSS LAYOUT HAS NOT
FLEXIBLE BEDDING MORTAR SHALL BE USED. ONE OR MORE OF THE OTHER BOTH WAYS. RODS SHALL BE TIED AT ALTERNATE INTERSECTIONS. PT.4. CO-ORDINATION
F.2. ALL WORKMANSHIP & MATERIALS SHALL BE IN ACCORDANCE WITH AS 2870 & SUBSIDENCE POLICY) STRUCTERRE RECOMMENDS A MASONRY ARTICULATION BEEN SIGHTED U.N.O. THESE PLANS SHALL BE PROVIDED TO TRUSS
MEASURES PROVIDED IN CLAUSE 5.3.7 MAY ALSO BE ADOPTED TO ACCOUNT FOR C.22. ALL TENSILE REINFORCEMENT TO BE LAPPED AS SHOWN IN TABLE BELOW: LAYOUT IS PREPARED PER DESIGN. THE TABLE BELOW IS TO BE CONSIDERED MANUFACTURER FOR CONFIRMATION. THIS OFFICE SHALL BE ADVISED OF ANY IF THESE DESIGN DRAWINGS ONLY DOCUMENT PART OF THE STRUCTURE, IT IS
CONCRETE CRACKING. NATIONAL CONSTRUCTION CODE (N.C.C.)
ONLY IF NO PLAN IS PROVIDED BY AN ENGINEER. DISCREPANCIES AS REVISED DESIGN MAY BE REQUIRED AT ADDITIONAL COST. THE BUILDER'S RESPONSIBILITY TO ENSURE ALL DESIGN DRAWINGS ARE
F.3. THE FOOTING DETAILS SHOWN ARE FOR THE SITE CLASSIFICATION STIPULATED. REINFORCEMENT BAR N12 N16 N20 N24
M.5. WHERE TREES HAVE BEEN REMOVED FROM THE BUILDING PLATFORM, ALL ROOTS GENERAL SAFETY NOTES: CO-ORDINATED BETWEEN ALL CONSULTANTS. FOR EXAMPLE, CO-ORDINATION TO
ARE TO BE THOROUGHLY GRUBBED OUT. ALL RESULTING HOLES SHALL BE WHILST EVERY CARE HAS BEEN TAKEN TO VERIFY THAT THE INFORMATION LAP LENGTH 400 600 700 800 MAX SPACING OF ARTICULATION JOINTS TO AS 4773 ENSURE APPROPRIATE SLAB THICKENINGS AND DETAILS FOR LOADBEARING AND
SHOWN IS CORRECT, STRUCTERRE CONSULTING ENGINEERS TAKE NO (UNREINFORCED MASONRY) U.N.O IT IS THE CLIENT'S RESPONSIBILITY TO PROVIDE THIS 'SAFETY IN DESIGN REPORT' TO
BACKFILLED WITH CLEAN SITE-BORNE MATERIAL TO MATCH THE SOIL LAYERS BRACING WALL ELEMENTS, CAST IN FIXINGS ETC.
INDICATED IN THE SOIL BORELOGS AND COMPACTED IN 150 MAX. LAYERS BY RESPONSIBILITY FOR VARIATIONS WHICH MAY OCCUR DUE TO VARIATIONS IN STRUCTURAL STEELWORK NOTES: 10mm JOINT SPACING (m) THE BUILDER (OR PROJECT MANAGER OR PRINCIPAL CONTRACTOR)
SITE CONDITIONS. SITE CLASS CONSTRUCTION & SURFACE FINISH PT.5. CONSTRUCTION LOADS
REPEATED ROLLING WITH AN EXCAVATOR IN ORTHOGONAL DIRECTIONS. S.1. ALL STEELWORK USED ON THIS PROJECT IS TO BE THIRD-PARTY CERTIFIED. < 4m HIGH 4m TO 8.Hm IN ACCORDANCE WITH THE WORK HEALTH AND SAFETY ACT AND REGULATIONS 2011,
F.4. FILL USED IN THE CONSTRUCTION OF A SLAB EXCEPT WHERE THE SLAB IS A&S EXPANSION JOINTS ONLY 7.0 6.0 BELOW IS THE LIST OF POTENTIAL CONSTRUCTION HAZARDS ASSOCIATED WITH IT IS BUILDER'S RESPONSIBILITY TO NOTIFY THE DESIGNER OF ANY SPECIFIC
M.6. ALL WATERPROOFING TO ARCHITECTURAL DETAILS (U.N.O) S.2. CONSTRUCTION CATEGORY CC2 REQUIRED FOR ALL WORK IN ACCORDANCE WITH
SUSPENDED SHALL CONSIST OF CONTROLLED FILL OR ROLLED FILL IN IMPLEMENTING THE DESIGN IS DOCUMENTED. LOADS THAT THE STRUCTURE MAY BE SUBJECT TO DURING CONSTRUCTION. NO
AS/NZS 5131 UNLESS NOTED OTHERWISE. EXTERNAL FACE FINISH 5.0 4.2
DRAINAGE NOTES: ACCORDANCE WITH AS 2870: M & M-D ALLOWANCE HAS BEEN MADE FOR CONSTRUCTION LOADS INCLUDING STACKING
S.3. DESIGN CONFORMS TO THE FOLLOWING STANDARDS: EXTERNAL RENDERED/PAINTED 5.0 3.9 HEALTH HAZARDS: OF MATERIAL ON DECKS, FLOORS OR ROOF PLATFORMS, LOADS IMPOSED DUE TO
D.1. ALL WORKMANSHIP & MATERIAL SHALL BE IN ACCORDANCE WITH AS2870. F.4.1 ROLLED FILL CONSISTS OF MATERIAL COMPACTED IN LAYERS BY REPEATED AS 4100 - STEEL STRUCTURES. H1, H2, EXTERNAL FACE FINISH 5.0 3.5 H.1. MANUAL MATERIAL HANDLING: MACHINERY, LIFTING DEVICES, IMPACT/VIBRATION/CYCLIC LOADS ETC. UNLESS
D.2. THE PRESENCE OF GROUND WATER WITH SURFACE SOIL MAY LEAD TO ROLLING WITH AN EXCAVATOR. ROLLED FILL SHALL NOT EXCEED 600mm AS/NZS 4600 - COLD-FORMED STEEL STRUCTURES. H1-D, H2-D NOTED ON THE DRAWINGS NO STRUCTURAL ALLOWANCE HAS BEEN MADE FOR
EXTERNAL RENDERED/PAINTED 4.5 3.2 THE BUILDER IS TO ENSURE THE COMPONENTS WITHIN THIS DESIGN WITH A MASS
CONSTRUCTION DIFFICULTIES DURING WET WEATHER. DRAINAGE SHALL BE COMPACTED IN LAYERS NOT MORE THAN 300mm FOR SAND MATERIAL OR FABRICATION AND ERECTION IN ACCORDANCE WITH THE PROVISIONS OF AS/NZS SPECIFIC LOADS ASSOCIATED WITH THE MAINTENANCE OF THE STRUCTURE. THE
400mm COMPACTED IN LAYERS NOT MORE THAN 150mm FOR OTHER P, E, E-D REFER NOTE 2 / LOCATIONS 4.0 U.N.O 3.0 U.N.O IN EXCESS OF 25 KG ARE LIFTED BY TWO OR MORE WORKERS OR USE MECHANICAL
CONSTRUCTED TO AVOID WATER PONDING AGAINST OR NEAR THE FOOTING. THE 5131. LIFTING DEVICE. WHERE THIS IS NOT PRACTICAL, SUPPLIERS OR FABRICATORS DESIGNER IS TO BE INFORMED OF ANY REQUIREMENTS NECESSARY TO
GROUND IN THE IMMEDIATE VICINITY OF THE PERIMETER FOOTING, INCLUDING MATERIAL. 1. THE SITE CLASS REFERS TO THE SOIL CLASSIFICATION AS DEFINED IN AS 2870 EXTERNALLY SUPPORT THE PLATFORMS, SCAFFOLDS ETC., AS REQUIRED.
S.4. ALL STEELWORK SHALL BE TEMPORARILY BUT SECURELY BRACED UNTIL ALL 2. JOINTS ON CLASS E, E-D & P SITES, REFER TO ENGINEER FOR ADVICE SHOULD BE REQUIRED TO LIMIT THE COMPONENT MASS.
THE GROUND UPHILL FROM THE SLAB ON CUT & FILL SITES, SHALL BE GRADED TO F.4.2 CONTROLLED FILL CONSISTS OF WELL GRADED SAND FILL UP TO 800mm FINAL BRACING, CLADDING AND STABILISING BRICK OR BLOCKWORK HAVE BEEN 3. IF 15mm JOINTS ARE TO BE USED, SPACINGS MAY BE RELAXED AS PER AS 4773 H.2. HAZARDOUS SUBSTANCES:THE BUILDER IS TO ENSURE DANGEROUS SITE PT.6. INSPECTION CERTIFICATE FOR NON-STRUCTURAL ELEMENTS
FALL 50mm MINIMUM AWAY FROM THE FOOTING OVER A DISTANCE OF 1.0m. DEEP, WELL COMPACTED IN NOT MORE THAN 300mm LAYERS BY VIBRATING COMPLETED, TO MAINTAIN THE STRUCTURE IN A SAFE AND STABLE CONDITION
WATER RUN-OFF SHALL BE COLLECTED AND CHANNELED AWAY FROM THE HOUSE PLATE OR VIBRATING ROLLER. NON SAND FILL UP TO 400mm DEEP, WELL MATERIALS INCLUDING CONTAMINATED SOILS AND ASBESTOS ARE ADEQUATELY ALL SUNDRY ELEMENTS OF THE STRUCTURE INCLUDING BUT NOT LIMITED TO
DURING CONSTRUCTION. ALL BRICK LINTELS TO BE PROPPED AT MID SPAN UNTIL
DURING CONSTRUCTION VIA SURFACE OR SUBSURFACE DRAINS CONNECTED TO COMPACTED IN NOT MORE THAN 150mm LAYERS BY A MECHANICAL ROLLER, BRICKWORK OVER IS A MINIMUM 3 DAYS OLD.
CLAY MASONRY NOTES: TREATED AND DISPOSED IN ACCORDANCE WITH AUTHORITY REGULATIONS, CLADDING DESIGN AND FIXINGS, WINDOWS, BALUSTRADES, STAIRS, SUSPENDED
THE LEGAL POINT OF DISCHARGE (LPoD). ANY PAVING SHALL ALSO BE SUITABLY INDUSTRY STANDARDS & PRACTICES. CEILINGS, INTERNAL FIT-OUT ITEMS AND ALL OTHER ELEMENTS NOT DETAILED IN
CLAY FILL SHOULD BE MOIST DURING COMPACTION. THE DEPTHS OF FILL CM.1. DESIGN CONFORMS TO AS 3700 - MASONRY STRUCTURES. CONSTRUCT IN
SLOPED AND DRAINED. ATTENTION TO SITE GRADING/SITE DRAINAGE IS S.5. BASE PLATES SHALL BE GROUTED BEFORE THE MEMBER IS SUBSTANTIALLY THE DESIGN DOCUMENTS MUST DESIGNED AND INSPECTED BY SUPPLIERS OR
GIVEN ABOVE ARE DEPTHS MEASURED AFTER COMPACTION. FOR LOADED. GROUT SHALL HAVE A MINIMUM STRENGTH f'c OF 25 MPa AND SHALL
ACCORDANCE WITH THE PROVISIONS OF AS 3700. SAFETY HAZARDS:
REQUIRED FROM THE START OF CONSTRUCTION. STRENGTH, f'uc = 12 MPa MANUFACTURERS.
COMPACTED DEPTHS GREATER THAN THAT GIVEN ABOVE THE FILL SHALL BE BE DRY PACK MORTAR RAMMED IN, OR AN APPROVED NON-SHRINK GROUT. SH.1. SLIPS, TRIPS AND FALLS:
D.3. WHERE FILLING IS PLACED ADJACENT TO THE BUILDING, THE FILLING SHALL BE SUBJECT TO CONTROL & TESTING. IF TEST FAILS THEN PIERS ARE REQUIRED. SALT RESISTANCE GRADE = EXPOSURE THE BUILDER IS TO ENSURE THE WALKING AND WORKING SURFACES ARE CLEAR PT.7. CHANGES TO CONTRACTUAL ARRANGEMENTS
COMPACTED & GRADED TO ENSURE DRAINAGE OF WATER AWAY FROM THE CONTACT THIS OFFICE PRIOR TO FURTHER CONSTRUCTION. S.6. U.N.O. ALL MATERIAL SHALL BE:
CM.2. CORE-FILLING GROUT TO BRICK PIERS = 20 MPa. U.N.O. AND FREE OF DEBRIS, PROVIDE SAFE ACCESS IN AND AROUND THE BUILDING SITE IT IS THE CLIENT'S AND THE BUILDER'S RESPONSIBILITY TO INFORM THE
FOOTINGS. GRADE 250 HOT-ROLLED PLATES COMPLYING WITH AS/NZS 3678.
F.5. TOP SOIL CONTAINING GRASS ROOTS OR OTHER ORGANIC MATERIAL SHALL BE INCLUDING ADEQUATE STAIRS, SCAFFOLDING, SECURE LADDER ACCESS, SAFE DESIGNER OF ANY CHANGE TO CONTRACTUAL ARRANGEMENTS BETWEEN THE
GRADE 300 UB, UC, PFC, EA, UA, FLATS & ROUNDS COMPLYING WITH AS/NZS CM.3. JOINTS TO BE TOOLED. REFER ARTICULATION MASONRY NOTES FOR
D.4. DISCHARGE FROM THE DOWNPIPES MUST BE DIRECTED AWAY FROM THE REMOVED FROM THE AREA ON WHICH THE SLAB IS TO REST. ARTICULATION JOINT REQUIREMENTS. WORKING PLATFORMS, ACCESS PATHS FREE FROM FALLING OBJECTS, ADEQUATE CLIENT AND THE BUILDER WHICH MAY IMPACT ON THE DESIGN AND SAFETY OF
3679.1.
BUILDING DURING CONSTRUCTION TO ENSURE WATER DOES NOT DISCHARGE OR RAILINGS, FALL ARREST SYSTEMS, ETC. THE DESIGN. THE CONSTRUCTION IS TO BE FULLY CARRIED OUT IN ACCORDANCE
F.6. IF ANY FOOTING IS LOCATED SUCH THAT A LINE DRAWN AT 45 DEGREES (FOR CLAY GRADE 300 WB, WC COMPLYING WITH AS/NZS 3679.2. CM.4. WEEPHOLES SHALL BE PROVIDED WHEREVER IT IS NECESSARY TO DRAIN
POND ADJACENT TO THE FOOTINGS. SH.2. MATERIAL HANDLING WITH ALL DESIGN DRAWINGS & NOTES AS DOCUMENTED. IF THE CONSTRUCTION
& 30 DEGREES FOR SAND) FROM ITS BASE INTERSECTS A PRIVATE SERVICE GRADE C350 CHS COMPLYING WITH AS 1163. MOISTURE FROM OR THROUGH MASONRY CONSTRUCTION. WHERE FLASHINGS CEASES AT ANY STAGE, THE DESIGNER IS TO BE NOTIFIED TO PROVIDE ADVICE ON
D.5. PLUMBING TRENCHES SHALL BE SLOPED AWAY FROM THE HOUSE & SHALL BE TRENCH, THEN PIERS ARE REQUIRED. REFER TO THE PRIVATE TRENCH SERVICE GRADE C450 RHS, SHS COMPLYING WITH AS 1163. ARE INCORPORATED IN THE MASONRY, WEEPHOLES SHALL BE PROVIDED IN THE IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT SITE MATERIALS ARE THE SAFETY OF COMPLETED CONSTRUCTION WORK AT THAT TIME.
BACKFILLED WITH CLAY IN THE TOP 300mm WITHIN 1.5m OF THE HOUSE. THE CLAY DETAIL FOR EXAMPLE. S.7. WELDING SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF AS/NZS 1554.1. MASONRY COURSE IMMEDIATELY ABOVE THE FLASHING, AT CENTRES NOT DELIVERED, TRANSPORTED, STORED AND POSITIONED IN A SAFE MANNER AND
USED FOR BACKFILLING SHALL BE COMPACTED. WHERE PIPES PASS UNDER THE EXCEEDING 1200mm. IN ACCORDANCE WITH THE PRODUCT SPECIFICATION, THE SITE SPECIFIC SAFETY PT.8. MATERIAL SPECIFICATION
F.7. EDGE BEAMS SHALL NOT BE FOUNDED ON ROLLED OR UNCONTROLLED FILL. WELDING CONSUMABLES SHALL BE GRADE E48XX OR W50X U.N.O.
FOOTING SYSTEM, THE TRENCH SHALL BE BACKFILLED WITH MOIST CLAY OR REFER EDGE BEAM FOUNDING DEPTH NOTE. ALL WELDS SHALL BE 6mm CFW SP CATEGORY U.N.O. PLAN & GENERAL SAFETY INDUCTION REGULATIONS. AT NO STAGE SHALL SITE ALL CONTRACTORS ARE REQUIRED TO COMPLY WITH MATERIAL PRODUCT
BENTONITE AT THE HIGH END OF THE FLOW TO RESTRICT THE INGRESS OF WATER ALL BUTT WELDS SHALL BE SP CATEGORY U.N.O. PERSONNEL PASS UNDER MATERIALS BEING LIFTED AND MOVED AROUND ON SPECIFICATION AS PER THE DESIGN DOCUMENTATION, AND IF REQUIRED TO
BENEATH THE FOOTING SYSTEM. F.8. WHERE PIERS ARE USED TO SUPPORT A SLAB ON UNCONTROLLED FILL, WIND/WALL TIE CLASSIDICATION
INSPECTION IS REQUIRED IN ACCORDANCE WITH AS/NZS 1554.1. SITE. REPLACE A PRODUCT SHOULD GET A WRITTEN ALTERNATIVE RECOMMENDATION
PLUMBING & DRAINAGE PIPES FOUNDED WITHIN SUCH FILL SHALL BE HUNG
D.6. EXCAVATIONS NEAR THE EDGE OF THE FOOTING SYSTEM SHALL BE BACKFILLED IN ALL GP / SP WELDS SHALL BE 100% VISUALLY SCANNED. WIND HORIZONTAL VERTICAL SH.3. EQUIPMENT FROM THE DESIGNER.
FROM THE SLAB MESH WITH CORROSIVE RESISTANT STRAPS. WALL TIE
SUCH A WAY AS TO PREVENT ACCESS OF WATER TO THE FOUNDATION. FOR SP FILLET WELDS SHALL HAVE 10% VISUAL EXAMINATION U.N.O CLASS (Vp) SPACING SPACING
EXAMPLE, EXCAVATIONS SHOULD BE BACKFILLED ABOVE OR ADJACENT THE F.9. FOR SATISFACTORY RESULTS, CONCRETE MUST BE CURED FOR AT LEAST 7 DAYS. SP BUTT WELDS SHALL HAVE 50% VISUAL EXAMINATION U.N.O. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE ALL CONSTRUCTION
N1 W28N1 LIGHT DUTY 600 600
FOOTING WITH MOIST CLAY, COMPACTED BY HAND-RODDING/TAMPING. POROUS CURING MAY BE ACHIEVED BY KEEPING THE CONCRETE MOIST, BY APPLYING A ALL GP WELDS SHALL HAVE 10% VISUAL EXAMINATION. EQUIPMENT IS USED IN ACCORDANCE WITH THE BEST INDUSTRY SAFETY
CURING MEMBRANE, OR BY COVERING THE CONCRETE WITH A MOISTURE N2 W33N2 MEDIUM DUTY 600 600 PRACTICES AND REGULATIONS. ALL SITE PERSONNEL ARE TO BE PROVIDED
MATERIAL SUCH AS SAND, GRAVEL OR BUILDING RUBBLE SHOULD NOT BE USED. S.8. BOLTS SHALL BE M16 DIAMETER U.N.O.
BARRIER. MANY BUILDERS FIND THAT THE MOST SATISFACTORY WAY TO CURE A N3 W41N3 MEDIUM DUTY 600 430 WITH ADEQUATE SPACE, VENTILATION AND APPROPRIATE PERSONAL
D.7. PENETRATIONS OF THE EDGE BEAMS & FOOTING BEAMS ARE TO BE AVOIDED, BUT SLAB IS TO COVER IT WITH SHEETS OF POLYETHYLENE AS SOON AS POSSIBLE BOLT CATEGORY TO BE 8.8/S COMPLYING WITH AS 4100, AS/NZS 1252 & AS/NZS PROTECTIVE EQUIPMENT TO UNDERTAKE THE WORKS AS REQUIRED. ALL SITE
WALL TIE SPACINGS AROUND OPENINGS 300 CTS. EACH WAY.
WHERE NECESSARY SHALL BE SLEEVED USING CLOSED-CELL POLYETHYLENE AFTER FINISHING. IF A SLAB IS MOIST WHEN COVERED & THE POLYETHYLENE IS 4291.1. U.N.O. MACHINERY AND ELECTRICAL EQUIPMENT ARE TO BE KEPT IN GOOD WORKING
(Vp = PERMISSIBLE STRESS METHOD)
LAGGING OR SIMILAR TO ALLOW FOR MOVEMENT. HELD SECURELY ONTO THE CONCRETE, THIS SYSTEM PROVIDES SATISFACTORY PROVIDE DESIGN ENGINEER WITH EVIDENCE OF COMPLIANCE WITH THESE CODES. ORDER WITH SAFETY TAGGING AND SERVICING WHERE APPLICABLE.
WALL TIE FIXINGS TO HAVE 50 MIN. EMBEDMENT INTO MORTAR.
D.8. CONNECTION OF STORMWATER DRAINS & WASTE DRAINS SHALL INCLUDE CURING OF THE CONCRETE. HOLDING DOWN BOLTS SHALL BE CATEGORY. 4.6/S
DEX I FU.N.O.
WERC S EB O T S E I T RE ENEV DEX I F E C AF

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES GENERAL NOTES LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 B.N. 23/02/22 S-001
SLAB DESIGN SUMMARY (U.N.O) BEAM & RIB REINFORCEMENT NOTE:
BOX SIZE 1090 x 1090 ALL BEAMS or INTERNAL RIBS WIDER THAN SPECIFIED IN
BOX HEIGHT 'bh' 300mm WAFFLE SLAB SCHEDULE SHALL BE REINFORCED WITH AN
SLAB THICKNESS 'st' 85mm ADDITIONAL BAR TOP & BTM. FOR EVERY 100 INCREASE
IN WIDTH. REFER INTERNAL RIB REINF'T FOR BAR SIZE.
OVERALL DEPTH 'od' 385mm ENSURE ALL EDGE BEAM REINF'T CONTINUES TO FIRST
EDGE BEAM WIDTH 'bw' 300mm INTERNAL RIB OR AS SHOWN ON PLAN (TYPICAL).
INTERNAL RIB WIDTH 'rw' 110mm
'ib' 1-N12 BAR TOP x 2000 LONG
INTERNAL BEAM WIDTH 300mm
EACH WAY, TIED TO UNDERSIDE
SLAB REINF'T SL82 MESH TOP OF SLAB MESH WHERE SHOWN
INTERNAL RIB REINF'T 1-N12 BAR BTM. (TYPICAL)
EDGE BEAM REINF'T 3-L12TM or 3-N12 BARS BTM
INTERNAL BEAM REINF'T 3-L12TM or 3-N12 BARS BTM
1st
GEOTECHNICAL INFORMATION POD
SITE CLASSIFICATION P
DATE 08/02/22 1-N12 BAR TOP, TIED TO
REFERENCE NO 152805 UNDERSIDE OF SLAB MESH
WHERE SHOWN (TYPICAL)

PC
LEVEL 1 COMPACTION N/A
MIN. BEARING CAPACITY 50 kPa
2-N12 BARS TOP, TIED TO MODULE 5 MODULE 4

PC
UNDERSIDE OF SLAB MESH
WHERE SHOWN (TYPICAL)

PC
PROVIDE 50 WIDE x 200 DEEP
x MAX. 2000 LONG REBATES
TO ALLOW FOR JACKING OF B1.
ALLOW FOR MIN. 600 LONG

PC
CONCRETE AT EACH END TO
SUPPORT FRAME OVER.

PC

PC

PC

PC
REFER TO SECTION 1.2

MODULE 3
P2

SITE PREPARATION NOTES


.ov
er

1) REMOVE SURFACE SOIL CONTAINING GRASS, ROOTS AND ORGANIC MATTER


FROM THE BUILDING AREA INCLUDING TOP 100mm OF EXISTING FILL.
2) ROLL THE WORKING SURFACE. IF SOFT SPOTS ARE ENCOUNTERED, THIS OFFICE
SHALL BE CONTACTED IMMEDIATELY FOR ADDITIONAL REQUIREMENTS.
3) CUT AND/OR FILL (OR SITE SCRAPE) SITE TO FORM A LEVEL BENCH .
4) ANY FILLING PLACED AS PART OF CUT/FILL OPERATIONS SHALL BE COMPACTED MODULE 2
AT OPTIMUM MOISTURE CONTENT IN 150mm MAXIMUM LAYERS BY REPEATED
ROLLING IN ORTHOGONAL DIRECTIONS, IN ACCORDANCE WITH AS2870-2011
Clause 6.4.2.
IF BUILDING PLATFORM IS SOFT OR SUSPECT THEN CONTACT THIS OFFICE FOR
P2
ADDITIONAL REQUIREMENTS. .ov
e r
5) UNPROTECTED BATTER SLOPES (HEIGHT H : LENGTH L) SHALL BE CONSTRUCTED

P1
.ov
AT H:L OF 1:2 FOR SAND, 1:4 FOR SILT, 1:2 FOR COMPACTED CLAY FILL AND 1:1

er
FOR NATURAL CLAY CUT BATTERS. WHERE MULTIPLE SOIL TYPES EXIST USE
SHALLOWEST SLOPE. APPROPRIATE SITE DRAINAGE SHOULD BE PROVIDED AS
NECESSARY TO PREVENT SOIL EROSION.
MODULE 1

LEGEND
STEEL PILES MUST BE FOUNDED INTO NATURAL STIFF
SOIL AND SHALL NOT BE FOUNDED/TERMINATED IN
FILL. THE MINIMUM FOUNDING DEPTH SHALL BE 2400 MODULE SPLITS
(UNO) BELOW GROUND LEVEL WHICH MAY NEED TO BE
INCREASED/DEEPER TO ACHIEVE A SAFE WORKING
LOAD OF 65 kN (TYPICAL) IN NATURAL SOIL.
ALTERNATIVELY PILES MAY BE TERMINATED BY
REFUSAL ONTO/INTO NATURAL SOLID ROCK. REFER
DETAILS. IT IS RECOMMENDED THAT THE PILING
CONTRACTOR UNDERTAKE TESTING TO CONFIRM PILE
DEPTHS REQUIRED TO ACHIEVE DESIGN REQUIREMENTS.
DENOTES WAFFLE POD EXTENSION.
300 MAX. EXTENSION FOR SINGLE STOREY.
200 MAX. EXTENSION FOR DOUBLE STOREY.

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FOOTING & SLAB PLAN LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE 1:100 @ A3 B.N. 23/02/22 S-100
MEMBER SCHEDULE
LABEL MEMBER SIZE COMMENTS
FJ1 100x50x2.0 DURAGAL RHS FLOOR JOISTS @ 450 CTS.
FJ2 100x50x2.0 DURAGAL RHS FLOOR JOISTS @ 450 CTS.
B1 100x50x4.0 DURAGAL RHS or RING BEAM. 2400mm MAX. SPAN
89x89x3.5 SHS
B2 100x50x4.0 DURAGAL RHS or FLOOR BEAM

MODULE SPLIT
MODULE SPLIT
89x89x3.5 SHS
BB1 100x50x4.0 RHS DURAGAL or UNDER BEARER
SCREW PILE. 1.2 MODULE 5 MODULE 4
REFER TO S-204
89x89x3.5 SHS 2400mm MAX. SPAN
FOOTING PLAN
P1 REFER TO ROOF FRAMING B1
P2 REFER TO ROOF FRAMING
PC 150 WIDE x 6mm THICK PLATE PLATE CONNECTION AT LOCATIONS
INDICATED (REFER TO DETAILS)

NOTE: ALL MEMBERS TO BE HOT DIPPED GALVANISED B.


PROVIDE 50 WIDE x 200 DEEP S LA
LE N B1

PC
x MAX. 2000 LONG REBATES
FF PLA

B1
TO ALLOW FOR JACKING OF B1. A
W TO
FJ1 FJ1

BB1
GE ER

B1
ALLOW FOR MIN. 600 LONG MODULE 5 MODULE 4
A

PC
CONCRETE AT EACH END TO R EF
SUPPORT FRAME OVER. GA R

B1
CONNECT THE B1 MEMBERS OF MODULE 4 TO MODULE 5 AS SHOWN

PC
REFER TO SECTION 1.2
VIA M12 8.8/S BOLT IN 18x25 HORIZONTAL SHORT SLOTTED HOLES.

B1
PROVIDE BOLTS @ 1200 CTS (MAX) & AT 200 (MIN) FROM ENDS.

B1
PROVIDE FJ1 BLOCK UNDER ALL WALLS FOR
P ALTERNATIVELY USE M12 8.8/TF BOLT IN 24 DIA. MAX. OVERSIZED
WALL BRACING FIXING REQUIREMENTS S-204 HOLES. EITHER BOLT OPTION TO HAVE 75x75x5 WASHER TO BOLT
(TYP.) B1 X
B1 HEAD & NUT.

PC
MODULE SPLIT B1

PC

PC

PC

PC
B1

FJ1

FJ1

FJ1

FJ1
FJ1
MODULE 3 MODULE 3
B1

FJ1
BB1
B1
P2

MODULE SPLIT
.ov

FJ1

FJ1
er

B1
FJ2

MODULE 2 MODULE 2

FJ1

B1
FJ1

FJ1

FJ1

FJ1

B2
FJ1

FJ1
B1

B2

BB1
B1
P2
.ov
e r B1 B1

P1
MODULE SPLIT
B1

.ov
er
BB1
B1

B1
MODULE 1
FJ1

MODULE 1

B1
MODULE SPLITS

INFILL PANEL LIPPED CEE


LEGEND PROFILE 89S41-100-550
@ 900 CTS.
DENOTES WET AREA RECESS.
50mm ANGLE REQUIRED AT JOISTS.

STEP
DENOTES STEP. REFER ARCHITECTURAL
DRAWINGS FOR DETAILS.

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES SUB-FLOOR FRAMING PLAN LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE 1:100 @ A3 B.N. 23/02/22 S-101
SLAB BEYOND

PROVIDE 1:20 MIN. FALL REFER WAFFLE SLAB NATURAL SURFACE PROVIDE 1:20 MIN. FALL
AWAY FROM HOUSE DETAILS & SCHEDULE. LEVEL. AWAY FROM HOUSE
(TYPICAL) (TYPICAL) 1000 MIN.

500 MIN.

150
TRENCH MESH.
REFER PLAN.
MEMBRANE MAY ALL EDGE BEAMS SHALL BE SUPPORTED AS PER DAMP-PROOF CUT TOE FOR DRAINAGE STEP HEIGHTS TO SUIT
TERMINATE HERE WITH EDGE BEAM FOUNDING DEPTH NOTE. MEMBRANE. DURING CONSTRUCTION. STEP LOCATIONS TO BE CONFIRMED ON SITE
LOCAL ACCEPTANCE.
TYPICAL SECTION THROUGH WAFFLE SLAB EDGE BEAM STEPPING DETAIL

TOP REINF'T INTERNAL RIB REINF'T. TOP REINF'T. INTERNAL RIB REINF'T.
IF REQUIRED. REFER SCHEDULE. REFER PLAN. REFER SCHEDULE.
REFER PLAN. 150
TOP REINF'T TOP REINF'T SLAB REINF'T. MIN
IF REQUIRED. IF REQUIRED. 20 TOP COVER.

'st'
REFER PLAN. REFER PLAN. (TYPICAL)
BEAM REINF'T.

'od'
REFER DESIGN

'bh'
750 DEEP MAX.
SUMMARY. BEAM REINF'T.

'st'

600 MIN.
REFER DESIGN
SUMMARY.
'od'

'bh'
MIN
150

DAMP-PROOF
MEMBRANE.
MIN BEAM REINF'T. INTERNAL BEAM REINF'T.
MEMBRANE MAY 150 150 MEMBRANE MAY REFER SCHEDULE. REFER SCHEDULE.
TERMINATE HERE WITH DAMP-PROOF TERMINATE HERE WITH DAMP-PROOF
LOCAL ACCEPTANCE. 'bw' MEMBRANE. LOCAL ACCEPTANCE. 'bw' MEMBRANE. 'bw' 'ib'
750mm MAX. DEPTH WHERE REQUIRED
BRICK VENEER EDGE BEAM CLADDING EDGE BEAM DEEPENED EDGE BEAM DEEPENED INTERNAL BEAM

INTERNAL RIB REINF'T. 800 MIN. LAP WITH


REFER SCHEDULE. SLAB MESH.
1-N12 TOP BAR 200 STANDARD COG. 150
DAMP PROOF COATING PROVIDE 1-N12 TOP BAR. TOP REINF'T SLAB REINF'T. MIN MIN
TO ARCHITECTURAL WHERE STEM WIDTH EXCEEDS IF REQUIRED. 40 TOP COVER.

'st'
SPECIFICATIONS. 220mm, PROVIDE 2-N12 BARS TOP. REFER PLAN. EXTERNAL ONLY.

'od'

751-1500 MAX.
151-750 MAX.

'bh'
BEAM REINF'T.
'st'

REFER SCHEDULE.
'od'

N12 BARS
'bh'

DAMP-PROOF
MIN
150

MEMBRANE. @ 300 CTS.


EACH WAY.
MIN

MIN
150

150
MIN.
MEMBRANE MAY 150 MEMBRANE MAY EDGE BEAM TO BE FOUNDED EDGE BEAM TO BE FOUNDED
TERMINATE HERE WITH INTERNAL RIB REINF'T. TERMINATE HERE WITH DAMP-PROOF 100 MIN. INTO NATURAL SOIL 100 MIN. INTO NATURAL SOIL
LOCAL ACCEPTANCE. 'bw' REFER DESIGN SUMMARY. LOCAL ACCEPTANCE. 'bw' MEMBRANE. 350 MIN. or CONTROLLED FILL UNLESS 'bw' or CONTROLLED FILL UNLESS
SUPPORTED ON PIERS. SUPPORTED ON PIERS.
750mm MAX. HEIGHT 1500mm MAX. HEIGHT
CLADDING VENEER EDGE BEAM PORTICO/ALFRESCO EDGE BEAM DEEPENED REBATE DEEPENED REBATE

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FOOTING & SLAB DETAILS - SHEET 1 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-200
90 WIDE x 70 HIGH HOB. SLAB REINF'T.
1 BAR TOP. LAP 600 WITH 20 TOP COVER.
SLAB MESH BEYOND RECESS (TYPICAL)
450 MIN. LAP CORRECT CORRECT

MAX
70
SLAB MESH.

'st'
REFER PLAN.
INCORRECT INCORRECT

'od'

MIN
MIN
150

150
REDUCED DEPTH
TYPICAL LOCATION SPLICE LOCATION
BEAM REINF'T. DAMP-PROOF INTERNAL RIB REINF'T.
WAFFLE PODS. REFER SCHEDULE. MEMBRANE. CONTINUE TO SERVICE SLAB.
'rw' 'bw' STAGGER SPLICES. DO NOT ALLOW MORE
THAN 3 BUNDLED BARS IN ANY LOCATION.
70mm MAXIMUM STEPDOWN.
REFER SLAB PLAN FOR LOCATION IF REQUIRED. REFER SLAB PLAN FOR LOCATION IF REQUIRED 2 LAYERS OF REINFORCEMENT
SHOWER RECESS SERVICE SLAB PLACEMENT REQUIREMENT

STRIP/TIE FOOTING TO BE POURED


AS INTEGRAL PART OF SLAB.
STRIP FOOTING 1000 MIN. LAP. SLAB REINF'T. INTERNAL BEAM REINF'T. SLAB REINF'T. INTERNAL RIB REINF'T.
TIE FOOTING 600 MIN. LAP 20 TOP COVER. REFER SCHEDULE. 20 TOP COVER. REFER SCHEDULE.
(TYPICAL) (TYPICAL)

'st'

'od'
'bh'
STRIP FOOTING
TIE FOOTING
DAMP-PROOF
'ib' 'rw' MEMBRANE.
WHERE REQUIRED
STRIP/TIE FOOTING LAPPING INTERNAL BEAM TYPICAL INTERNAL RIB
600 LAP INTERNAL RIB REINF'T.
REFER SCHEDULE.
SLAB REINF'T. INTERNAL RIB REINF'T. STANDARD COG.

'st'
20 TOP COVER. REFER SCHEDULE.
(TYPICAL) STANDARD COG.

'bh'
1-N12 TOP BAR SLAB REINF'T. 450 MIN. SLAB REINF'T.
20 TOP COVER. 20 TOP COVER.

'st'
(TYPICAL) (TYPICAL)
20mm FALL TO
'bh'
SLAB EDGE TO 600 LAP N12 HORIZ. BARS
'od'

GARAGE OPENING. @ 300 CTS.


'st'

N12 VERT. BARS


'od'

'od'
@ 300 CTS.
'bh'
MIN
150

INTERNAL BEAM INTERNAL BEAM


DAMP-PROOF REINF'T. REINF'T.
MIN. MEMBRANE. REFER SCHEDULE. REFER SCHEDULE.
BOTTOM REINF'T. 150
REFER SCHEDULE. 300 MAX. 150
150 MIN. INTERNAL RIB REINF'T. INTERNAL RIB REINF'T. DAMP-PROOF
'rw' REFER SCHEDULE. 300 MIN. REFER SCHEDULE. 'ib' MEMBRANE.

REFER SLAB PLAN FOR LOCATION IF REQUIRED. 200mm MAXIMUM STEPDOWN 344mm MAXIMUM STEPDOWN 345-1200mm MAXIMUM STEPDOWN
WIDENED GARAGE EDGE BEAM SLAB STEPDOWN STEPPED BEAM STEPPING BEAM

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FOOTING & SLAB DETAILS - SHEET 2 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-201
NON-SHRINK
STRUCTURAL GROUT.
APPLIED IN ACCORDANCE
WITH MANUFACTURERS
SPECIFICATIONS.

15-30mm BRICK/CLADDING OVERHANG CUT BOTTOM


REINFORCEMENT.
SLAB RECTIFICATION

NOTE:
ADD 1-N12 x 1200 LONG BAR FOR
EACH CUT WIRE IN EACH DIRECTION
FOR SLAB TOP REINFORCEMENT.

IN THE EVENT THAT THE SLAB MESH


NON-SHRINK
NEEDS TO BE CUT DUE TO PIPE
STRUCTURAL GROUT.
PENETRATION, PROVIDE A 600x600

110
APPLIED IN ACCORDANCE
OFF CUT OF MESH, LAP & TIE TO
WITH MANUFACTURERS
UNDERSIDE OF SLAB MESH.
SPECIFICATIONS.

ADDITIONAL WIDEN RIB 110mm PAST PIPE


BAR BOTTOM. FOR FULL PANEL WIDTH.
1 ADDITIONAL BOTTOM BAR
CROSS-BEAM TO CROSS-BEAM.
15-20mm FRAME OVERHANG
SLAB RECTIFICATION SLAB PIPE PENETRATION DETAIL
BLOCKOUT IN FOOTING LAGGING THICKNESS AS PER TABLE,
ZONE OF INFLUENCE APPROX. 2x PIPE ∅ SQ. PENETRATION OF THE EDGE BEAM BY 1-N12 BAR TOP AT EDGE OF SLAB. EXTEND
45° FOR CLAY PLUMBING SHALL BE SLEEVED 600 PAST EDGE OF REBATE EACH SIDE.
REINF'T BAR N12 N16 N20 N24 EDGE BEAM
30° FOR SAND
LAP LENGTH 400 600 700 800 PIER/BEAM FOUNDED

'D'
BELOW INFLUENCE OF ZONE A REFER DETAIL 1
REINF'T BAR LAPPING SERVICE TRENCH. ZONE A

= = =
ZONE B NO THICKENING REQ'D

'OD'
ZONE B

Max.
200
ZONE C ZONE C REFER DETAIL 2
TRENCH MESH
a) OVERLAP OF SIDE OF SHEETS '3D'
50mm BTM. COVER
SERVICE TRENCH

SERVICE TRENCH
EDGE BEAM THICKENING DETAIL 1 PIPE PLACEMENT DETAIL
°

45
45

30°
b) OVERLAP OF ENDS OF SHEETS 30°
TRENCH MESH LAGGING THICKNESS, (MIN. 40mm)
50 BTM. COVER PENETRATION OF THE EDGE BEAM BY MINIMUM REQUIREMENTS FOR LAGGING
PLUMBING SHALL BE SLEEVED THICKNESS
EDGE BEAM
PRIVATE SERVICE TRENCH NOTES 75
SITE MINIMUM LAGGING THICKNESS
c) OVERLAP SIDE AND END OF SHEETS CLASS (mm)
'D'

ST.1. PLUMBING AND DRAINAGE TRENCHES SHALL BE LOCATED OUTSIDE THE


INFLUENCE OF THE FOOTINGS. THE HORIZONTAL DISTANCE TO ANY TRENCH "M" 20
EXCAVATION MUST BE GREATER THAN THE TRENCH DEPTH IN ACCORDANCE "H1" 20
WITH CLAUSE 6.3 FROM AS 2870-2011. THIS HORIZONTAL CLEARANCE TO BE ALT. TO 2 LAYERS OF MESH, "H2" 40
INCREASED MORE THAN TWICE THE TRENCH DEPTH FOR SAND SITES. FOOTING BEND THE SINGLE LAYER
d) NOT ACCEPTABLE PIERS WILL BE NECESSARY UNDER ALL EDGE BEAMS IF THESE CONDITIONS 1000 Min.
"E" 40
AND MAINTAIN 75mm
ARE NOT MET. "P" 40
SEPARATION DISTANCES
ST.2. TRENCH BACKFILL SHALL BE COMPACTED IN ACCORDANCE WITH CLAUSE 5.5 OF
AS/NZS 3500.2-2003 OR CLAUSE 7.2.13 OF AS/NZS 3500.3-2003. SAND EDGE BEAM THICKENING DETAIL 2
BEDDING AND SURROUND SHALL BE BLOCKED WITH A CLAY PLUG WHEREVER
MESH TO BE LAPPED AS SHOWN ABOVE TRENCHES PASS UNDER THE EDGE OF ANY SLAB.
MESH LAPPING PRIVATE SERVICE TRENCH DETAIL PLUMBING PIPE PENETRATION DETAILS
APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.
GERVASE PURICH CREATION HOMES FOOTING & SLAB DETAILS - SHEET 3 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-202
PROVIDE TOP REINF'T OVER REFER WAFFLE SLAB
PIERS/PILES. (TYP) DETAILS & SCHEDULE.
REFER FOOTING PLAN.

BENCH LEVEL BENCH LEVEL

UNCONTROLLED FILL

REFER PLAN
L BORED PIER SIZE SUMMARY (U.N.O)

OVERALL DEPTH
NDING MATERIA CONCRETE BORED PIER
EN DED FOU REFER TO FOOTING PLAN OVERALL DEPTH MINIMUM DIAMETER & REINF'T
RECOMM FOR LOCATION & SIZE. typ.
UP TO 3.5m 450∅
450∅ WITH 4-N12 BARS WITH R6 SPIRAL
3.6m TO 6.0m
LIGS @ 300
PIERS TO BE POURED
INDEPENDENT FROM SLAB WHEN 'dia' 6.0m AND OVER REFER TO ENGINEER
OVERALL DEPTH EXCEEDS 1000.

TYPICAL SECTION THROUGH WAFFLE SLAB

BLADE PILE UNDER.


SCREW PILE CAP SCHEDULE
INTERNAL RIB REINF'T.

.
SQ
REFER SCHEDULE. SCREW PILE NOTES LOAD PILE SIZE

0
60
SCREW PILE LOCATION, LOADS AND MINIMUM DEPTH INDICATED ONLY. SCREW PILES 200 kN 158 DIA.
HAVE NOT BEEN DESIGNED UNDER THE SCOPE OF THIS PROJECT. THE PILE DESIGN IS
THE RESPONSIBILITY OF THE PILING CONTRACTOR U.N.O. STRUCTERRE IS ABLE TO 150 kN 114 DIA.
PROVIDE THIS DESIGN SERVICE IF REQUIRED. 100 kN 89 DIA.
1. PILES ARE TO BE DESIGNED IN ACCORDANCE WITH AS 2159-2009. THE PILE 75 kN 75 DIA.
CERTIFICATE AND DESIGN DOCUMENTATION SHALL BE SUBMITTED TO THE CLIENT
STEEL BLADE PILES PRIOR TO INSTALLATION. WE WOULD RECOMMEND A COPY IS ALSO PROVIDED TO SCREW PILES
PROVIDE BLADE PILES TO THE MINIMUM DEPTH STRUCTERRE FOR REFERENCE PRIOR TO INSTALLATION. THE PILE DESIGN PROVIDE SCREW PILES TO THE MINIMUM DEPTH
AND TO THE WORKING LOADS INDICATED ON THE DOCUMENTATION AND CERTIFICATE SHALL REFERENCE FACTORS SUCH AS: AND TO THE WORKING LOADS INDICATED ON THE
FOOTING PLAN. · ULTIMATE GEOTECHNICAL STRENGTH (RD,UG) FOOTING PLAN. PROVIDE HELIX AS REQUIRED.
· GEOTECHNICAL STRENGTH REDUCTION FACTOR (ΦG)
NOTE · ARR NOTE
BLADE PILES TO BE LOCATED CENTRAL TO RIBS. · SHAFT SIZE & THICKNESS ADDITIONAL REINFORCEMENT IS TO BE PROVIDED
ADDITIONAL REINFORCEMENT IS TO BE PROVIDED · HELIX SIZE & THICKNESS IN THE TOP OF THE SLAB OVER SCREW PILES.
PLAN VIEW AT INTERNAL RIB IN THE TOP OF THE SLAB OVER BLADE PILES. · DEPTH PLAN VIEW AT INTERNAL RIB REFER TO FOOTING PLAN.
INTERSECTION REFER TO FOOTING PLAN. · CORROSION INTERSECTION
· SOIL PROPERTIES
INTERNAL BEAM REINF'T. INTERNAL RIB REINF'T. · GROUND WATER (IF APPROPRIATE) CUT REINFORCEMENT AS REQUIRED WIDENED RIB REINF'T.
REFER SCHEDULE. REFER SCHEDULE. · PILE TESTING TO PROVIDE 40mm MIN. COVER REFER SCHEDULE.
2. PILES ARE TO BE INSTALLED ACCORDING TO AS2159-2009 BY A CONTRACTOR, WITH
SUFFICIENT EXPERIENCE AND APPROPRIATE INDUSTRY QUALIFICATIONS AND
ACCREDITATIONS.

75
3. PILE INSTALLATION PARAMETERS SHALL BE USED TO DETERMINE CONSISTENCY
BETWEEN PILES AND TO CONFIRM IF THE PILE IS INSTALLED IN THE DESIGN
FOUNDING MATERIAL. IF PILE INSTALLATION PARAMETERS ARE INCONSISTENT,
THEN PILES ARE TO GO DEEPER UNTIL READINGS ARE CONSISTENT. Y Y
4. IF THE INSTALLATION PARAMETERS REDUCE OR THE PILE DEPTH BECOMES
EXCESSIVE, CONTACT THE ENGINEER.
BLADE PILE 5. PILES INSTALLED TO ROCK ARE TO BE CONFIRMED BY AN EXPERIENCED SCREW PILE
CONTRACTOR, WITH SUFFICIENT EXPERIENCE AND APPROPRIATE INDUSTRY
QUALIFICATIONS AND ACCREDITATIONS.
PLAN VIEW BLADE PILE BLADE PILE UNDER 6. ALL PILES ARE TO BE 350 GRADE U.N.O. SCREW PILE UNDER
UNDER INTERNAL BEAM INTERNAL RIB 7. NO RECYCLED STEEL TUBE SHALL BE USED INTERNAL BEAM SECTION Y-Y

TYPICAL BLADE PILE DETAILS TYPICAL SCREW PILE DETAILS

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FOOTING & SLAB DETAILS - SHEET 4 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-203
W
-
Y Z
- -
2-N12 BARS TOP FOR DETAILS NOT SHOWN
B1 B1 STEP OR NOTED. REFER TO
TYPICAL EDGE BEAM DETAIL
FLOORING FLOORING 1-N12 BAR TOP
150 MIN. CLEARANCE
FJ1 FJ1 FJ1

150 MIN.
BB1

150 MIN.
NSL NSL

'od'

'od'
150
NSL
SCREW PILE. SCREW PILE. 'bw' 'bw'
REFER TO PLAN REFER TO PLAN BEAM REINF'T
REBATE BEYOND TO ALLOW REFER DESIGN
FOR JACKING OF B1. SUMMARY
TYPICAL B1 TO SCREW PILE DETAIL TYPICAL BB1 TO SCREW PILE DETAIL
SCALE: 1:20 SCALE: 1:20 SCREW PILE. REFER TO PLAN
SECTION 1.2 AND TYPICAL DETAILS

SCALE: 1:20 S-101

NOTE:
BUILDER TO ENSURE THAT APPROPRIATE
COATING IS APPLIED TO ALL SUBFLOOR
MEMBERS INCLUDING FASTENER’S TO ENSURE
DURABILITY OF THESE MEMBERS ACHIEVE THE
MINIMUM DESIGN LIFE OF THE STRUCTURE

CONNECT FJ1 TO B1 VIA CONNECT FJ1 TO BB1 CONNECT B1 TO PLATE


1-JOIST HANGER (1.0 BMT, G300) VIA 2-MULTIGRIPS (1.0 VIA 4-14g SERIES 500

MODULE SPLIT
W/3-12g SCREWS PER TAB (typ.) BMT, G300) W/3-12g TEK SCREWS
HEBEL CLADDING
SCREWS PER TAB (typ.) CONNECT FJ1 TO B1 VIA B1
1-JOIST HANGER (1.0 BMT, G300) MODULE 5 MODULE 4
W/3-12g SCREWS PER TAB (typ.)
B1 FLOORING B1
FLOORING FLOORING FLOORING
150 MIN. CLEARANCE

STEP

150 MIN. CLEARANCE


FJ1 FJ1 FJ1 B1 FJ1 FJ1
CONNECT B1 TO L-SHAPE
BRACKET VIA 4-14g CONNECT B1 TO L-SHAPE L-SHAPE BRACKET

MIN.
140
SERIES 500 TEK SCREWS BRACKET VIA 4-14g BB1

200
TRENCH
NSL SERIES 500 TEK SCREWS NSL
NSL
150 MIN.

150 WIDE x 6mm THICK PLATE


2-M12 CHEMSET ANCHORS or ANKASCREWS
70mm EMBEDMENT INTO FOOTING
SCREW PILE. 140mm MIN. EDGE DISTANCE. (typ.) SCREW PILE.
REFER TO PLAN REFER TO PLAN
REBATE BEYOND TO ALLOW
FOR JACKING OF B1.
50 REBATE

SCREW PILE.
REFER TO PLAN DETAIL W
SCALE: N.T.S. -

DETAIL Y DETAIL X
SCALE: N.T.S. - SCALE: N.T.S. S-101

DETAIL Z
SCALE: N.T.S. -

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FOOTING & SLAB DETAILS - SHEET 5 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-204
C1

6 CFW ALL AROUND

B1 - RING BEAM

TYPICAL C1 TO (RHS) RING BEAM DETAIL


SCALE: N.T.S.

X
25mm THICK PACKING PLATE 25mm THICK PACKING PLATE
FSBW B1 TO B1 (ALL AROUND)
6 CFW ALL AROUND
B1 - RING BEAM
B1 - RING BEAM B1 - RING BEAM B1 - RING BEAM
B1 - RING BEAM 5mm THICK PACKING PLATE

2-L2g SCREWS X
RING BEAMS (RHS) DETAIL 65x35x3.0 RHS 65x35x3.0 RHS

MIDDLE SPLIT
SCALE: N.T.S.
B1 SPLICE DETAIL SECTION X-X
SCALE: N.T.S. SCALE: N.T.S.

INFILL PANEL DSF


90x1.0mm PANEL.
BUILT ON SITE
CONNECT FJ1 TO BB1
VIA 2-MULTIGRIPS (1.0
TIMBER POST TIMBER POST BMT, G300) W/2-12g
SLOTTED PLATE INTO
TIMBER POST SCREWS PER TAB (typ.)
4mm GALVANISED STIRRUP. 4mm GALVANISED STIRRUP. B1 B1
CONNECT TIMBER POST TO CONNECT TIMBER POST TO
STIRRUP WITH 2-M10 BOLTS. STIRRUP WITH 2-M10 BOLTS.
CONNECT STIRRUP TO STEEL CONNECT STIRRUP TO STEEL 400mm
BEAM VIA 2-M12 BOLTS. BEAM VIA 2-M12 BOLTS.
B1/FJ1 B1 B1/FJ1 B1

TIMBER POST TO BEAM DETAIL (OPTION 1) TIMBER POST TO BEAM DETAIL (OPTION 2) TYPICAL MODULE SPLIT DETAIL
SCALE: 1:20

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FOOTING & SLAB DETAILS - SHEET 6 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-205
MEMBER SCHEDULE LOAD BEARING WALLS
LABEL MEMBER SIZE COMMENTS ALL EXTERNAL WALLS ARE LOAD BEARING
RL1 TRUSS LINTEL BY OTHERS INTERNAL LOAD BEARING WALLS ARE
RL2 TRUSS LINTEL BY OTHERS DENOTED AS ON PLAN.
VB1 100x50x4.0 DURAGAL RHS OR ALL STEEL FRAMING IS TO BE IN
89x89x3.5 SHS ACCORDANCE WITH AS4600.
VB2 100x50x4.0 DURAGAL RHS OR
89x89x3.5 SHS
P1 200x150 HARDWOOD TIMBER POST
P2 150x150 HARDWOOD TIMBER POST ROOF MODULE
GL1 230x75 PFC LOCATE JUST UNDER CEILINGS
LEVEL
RT1 ROOF TRUSS BY OTHERS RL1
TC BRACED WALL (2.4m MIN. LONG) TEMPORARY CARRY WALLS FOR
LIFTING PURPOSE ONLY

RL1
4S

RL1

GL1
MODULE 5 MODULE 4

RL1
4S

TC
RT1
RL1

RL2
MODULE 3

RL1
P2

RL1
TC

TC

TC

TC

VB1
RL1
VB2

MODULE 2

RL2
RL1

TC

TC

TC
P2 P1
VB1
TC

TC

TC

VB2
RL2

MODULE 1
RL2

RL2 RL2
MODULE SPLITS SCHEMATIC PLAN

FRAMING DESIGN BASED ON


SHEET ROOF LOADS

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES ROOF FRAMING PLAN LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE 1:100 @ A3 B.N. 23/02/22 S-300
2/12g SCREWS 2/12g SCREWS 4/12g SCREWS BOXED STUD 6/12g SCREWS
@ 300 CTS. @ 300 CTS. @ 300 CTS. OPTION A. @ 300 CTS.

2S DETAIL 2S DETAIL 3S DETAIL 4S DETAIL


(BOXED STUD)

STUD SUPPORT DETAILS


(UNLESS NOTED OTHERWISE)

QR CODE BRICKWORK LINTEL TABLE


INSTRUCTIONS/INFORMATION HEIGHT OF SPAN OF OPENING (mm)
BRICKWORK
SUPPORTED 1200 1500 1800 2100 2400 2700 3000 3300 3600 >3600
500 A A A A A B C D D E
1000 A A A A B D D D D E
1500 A A A B D D D D E E
VIEW PRIOR TO OPENING/VIEWING 2000 A A B D D D D E E E
ANY 3D DETAILS. 2500 A A B D D D E E E E
3000 A A C D D E E E E E
3500 B C D E E E E E E E
MINIMUM END
LINTEL TYPE SIZE COMMENTS
BEARING (mm)
A 100x6 EA. 150 (U.N.O)
B 100x8 EA. 150 (U.N.O)
C 100x10 EA. 150 (U.N.O)
D 150x100x10 UA. 150 LEG VERTICAL. 150 (U.N.O)
E ENGINEER TO DESIGN
NOTES:
1. THIS BRICKWORK LINTEL TABLE APPLIES ONLY TO LINTELS SUPPORTING
BRICKWORK ONLY.
2. ALL STEEL ANGLES TO BE HOT DIPPED GALVANISED.
3. WHERE LINTEL SPAN ≤ 1.0m, PROVIDE 100 MIN. END BEARING TO EACH END.

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FRAMING DETAILS - SHEET 1 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-400
8 THICK END PLATE.
C PURLIN RHS 6 CFW TO RHS.
2-M12 BOLT TO POST.

7D
TIMBER POST
1mm THICK G300 ANGLE.

5D
4/No. 10G SCRES EACH FACE.

C PURLIN RHS TO TIMBER POST 1-M10 BOLT TO EACH END


AND @ 900 CTS. OR SC960-PA
(UNLESS NOTED OTHERWISE) RAMSET PINS @ 200 CTS. CUT BEAM TO SUIT. 10 THICK STIFFENER
PLATE THICKNESS TO (EACH SIDE FOR UB/UC)
MATCH FLANGE THICKNESS 6 CFW TO STEEL.
OF STEEL MEMBER.
1-M10 BOLT TO EACH END
1mm THICK G300 ANGLE. AND @ 900 CTS. OR SC960-PA
4/No. 10G SCRES EACH FACE. RAMSET PINS @ 200 CTS.
RHS/C PURLIN STEEL

MIN.
120
PURLIN TO PURLIN DETAIL
(UNLESS NOTED OTHERWISE)
STEEL STEEL COLUMN
or STUD SUPPORT.
REFER RELEVANT DETAIL
REFER STEEL COLUMN 1-M10 BOLT TO EACH END COPE FLANGES AS FOR CONNECTION.
TO TOP PLATE DETAIL. AND @ 900 CTS. OR SC960-PA REQUIRED.
RAMSET PINS @ 200 CTS. DO NOT OVER CUT

STEEL TO SIDE OF STUD WALL PLATE TO STEEL STEEL CHAMFER DETAIL


(UNLESS NOTED OTHERWISE)
STEEL LINTEL STEEL
COLUMN

8 THICK CLEAT PLATE.


6 CFW TO STEEL.
8 THICK CLEAT. REFER BOLT SCHEDULE.
100
6 CFW TO COLUMN. 8 THICK STIFFENER
REFER BOLT SCHEDULE. 8 THICK STIFFENER. 8 THICK STIFFENER.
6 CFW TO BEAM. (EACH SIDE FOR UB/UC) (EACH SIDE FOR UB/UC)
REFER BOLT SCHEDULE. 6 CFW TO STEEL. 6 CFW TO STEEL.

8 THICK CAP. STEEL STEEL


6 CFW TO COLUMN.

STEEL BEAM STEEL STEEL BEAM STEEL


COLUMN

REFER STEEL TO
TOP PLATE DETAIL.

COLUMN

COLUMN
8 THICK CLEAT. 8 THICK STIFFENER
REFER TO FRAMING PLAN 10 THICK CAP PLATE. 10 THICK CAP PLATE.
6 CFW TO COLUMN. 6 CFW TO BEAM. FOR SUPPORTING STUD.
REFER BOLT SCHEDULE. 6 CFW TO COLUMN. 6 CFW TO COLUMN.
REFER BOLT SCHEDULE.
2-M16 8.8/S BOLTS (PFC) 2-M16 8.8/S BOLTS (PFC)
4-M16 8.8/S BOLTS (UB/UC) 4-M16 8.8/S BOLTS (UB/UC)
BOLT SCHEDULE BOLT SCHEDULE BOLT SCHEDULE
BEAM DEPTH BOLTS BEAM DEPTH BOLTS
BEAM DEPTH BOLTS
150 to 230 2-M16 8.8/S 150 to 230 2-M16 8.8/S
150 to 230 2-M16 8.8/S
250 to 360 3-M16 8.8/S 250 to 360 3-M16 8.8/S
250 to 360 3-M16 8.8/S
380 to 410 4-M16 8.8/S 380 to 410 4-M16 8.8/S

STEEL TO SIDE OF COLUMN STEEL TO STEEL BEAM DETAIL STEEL TO STEEL OVER STUD STEEL TO TOP OF COLUMN STEEL OVER COLUMN
(UNLESS NOTED OTHERWISE) (UNLESS NOTED OTHERWISE) (UNLESS NOTED OTHERWISE) (UNLESS NOTED OTHERWISE) (UNLESS NOTED OTHERWISE)

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FRAMING DETAILS - SHEET 2 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-401
100x100x6 EA. 10 THICK CAP PLATE.

COLUMN
8 THICK STIFFENER. 6 CFW TO PFC. 8 THICK STIFFENER. 2-M16 8.8/S BOLTS (PFC BELOW) 6 CFW TO COLUMN. 45
6 CFW TO PFC. 2-M16 8.8/S BOLTS (PFC BELOW) EACH SIDE OF BEAM 4-M16 8.8/S BOLTS (UB/UC BELOW) 2-M16 8.8/S BOLTS (PFC BELOW)
4-M16 8.8/S BOLTS (UB/UC BELOW) 6 CFW TO UB/UC. 4-M16 8.8/S BOLTS (UB/UC BELOW) PROVIDE ADDITIONAL 10 THICK CAP PLATE.
TOP PLATE IF REQUIRED. 6 CFW TO COLUMN.
2-M12 8.8/S BOLTS.

STEEL STEEL STEEL

8 THICK STIFFENER. 8 THICK STIFFENER. 8 THICK STIFFENER

45
COLUMN
(EACH SIDE FOR UB/UC) (EACH SIDE FOR UB/UC) (EACH SIDE FOR UB/UC)
6 CFW TO UB/UC. 6 CFW TO UB/UC. 6 CFW TO STEEL.

PFC TO TOP OF STEEL UB/UC TO TOP OF STEEL COLUMN TO TOP OF STEEL


(UNLESS NOTED OTHERWISE)

45
STEEL COLUMN TO TOP PLATE DETAIL
2/14g TEK SCREWS 1-M10 8.8/S BOLT TOP, (UNLESS NOTED OTHERWISE)
TOP, BTM. & MID-HEIGHT. BOTTOM & MID-HEIGHT.

8 STIFFENER PLATE.
(EACH SIDE FOR UB/UC)
6 CFW TO BEAM. 2-M12 CHEMSETTM REO 502TM

45

65
ANCHOR BOLTS INSTALLED
TO MANUFACTURER'S
SPECIFICATIONS (TYPICAL)

STEEL
WHERE BASE PLATE IS
FOUNDED BELOW GROUND
PAINT BASE OF COLUMN

COLUMN

45
WITH A BITUMINOUS PAINT

65
6 CFW ALL AROUND TO MANUFACTURER
TO BEAM. RECOMMENDATIONS UP TO
100mm ABOVE GROUND.
STUB COLUMN

10 BASE PLATE.

45
10 BASE PLATE.

65
6 CFW TO STUB COL. 6 CFW TO COLUMN.
2-M16 8.8/S BOLTS.

120

120
20mm NON-SHRINK
GROUT UNDER PLATE
8 STIFFENER PLATE. (OPTIONAL) SURFACE MOUNTED BASE PLATE INTERNAL BASE PLATE ON SLAB EDGE
6 CFW TO BEAM.

OPTION A OPTION B PROVIDE MINIMUM EDGE DISTANCES TO BOLTS


(REFER MANUFACTURER'S DETAILS)
STEEL FRAME TO STEEL COLUMN STUB COLUMN DETAIL SHS COLUMN BASE PLATE DETAIL
(UNLESS NOTED OTHERWISE) (UNLESS NOTED OTHERWISE)

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FRAMING DETAILS - SHEET 3 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-402
30x1.0mm (G550) METAL STRAP.
LOOPED OVER PLATE AND FIXED TO
VERTICAL MEMBER & POST WITH
4-10g SCREWS TO EACH END.

COLUMN

COLUMN

COLUMN
10 THICK CAP PLATE. 10 THICK CAP PLATE. CONNECT VERTICAL WEBS VIA
6 CFW TO COLUMN. 6 CFW TO COLUMN. 4Nº12 SERIES 500 SCREWS.
2-M16 8.8/S BOLTS. 2-M16 8.8/S BOLTS. (MIN 16kN SHEAR CAPACITY)

TRUSS TO TOP OF SHS COLUMN TRUSS OVER SHS COLUMN TRUSS TO SIDE OF SHS COLUMN
(UNLESS NOTED OTHERWISE) (UNLESS NOTED OTHERWISE) (UNLESS NOTED OTHERWISE)

APPROVED CLIENT SHEET PROJECT ADDRESS DESIGN BY REVISION PROJECT NO.


GERVASE PURICH CREATION HOMES FRAMING DETAILS - SHEET 4 LOT 38 SANTA CRUZ WAY, BERWICK B.N. A 152805
ENDORSED BUILDING ENGINEER: CIVIL TYPE E1 - HEATHCOTE (GABLE) CHECKED DATE SHEET NO.
ENDORSED ENGINEER REGISTRATION NO: PE0003141 SCALE N.T.S @ A3 B.N. 23/02/22 S-403