114210450boulevardtime_square2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 298

Prequalification Document

For
BOULEVARD-TIME SQUARE-2
SILAH-LLC

AIR OUTLETS
& DUCT ACCESSORIES

Consultant Name:
Khatib and Alami
Contractor Name:
‫مؤسسة أزل للتجارة‬
Ref. No.: 114210450
INDEX
1. COMPANY PROFILE
A. PROFILE
B. ORGANIZATION CHART
C. LOCATION MAP & CONTACT
2. APPROVALS
A. APPROVAL LIST
B. SAMPLE OF APPROVALS COPIES
3. GOVERNMENT CERTIFICATES
A. ESTABLISHMENT REGISTRATION
CERTIFICATE
B. CHAMBER OF COMMERCE MEMBERSHIP
C. INDUSTRIAL INVESTMENT LICENSE - SAGIA
D. ZAKAT CERTIFICATE
E. VAT REGISTRATION
F. SOCIAL INSURANCE CERTIFICATE - GOSI
G. SAUDIZATION CERTIFICATE
4. QUALITY CERTIFICATES
A. ISO 9001
B. UL CERTIFICATE - FIRE DAMPER
C. UL CERTIFICATE - FUSIBLE LINK
D. HENKEL - CERTIFICATE OF APPROVAL
E. INTERTEK - TEST REPORTS
5. DATA SHEETS
1. Company Profile
A. Profile
B. Organization Chart
C. Location map & Contact
Company Profile

Rabie Al-Takyeef Factory is a privately owned company with


head quarter in Riyadh.

Rabie Al-Takyeef Factory (RTF) has become now one of the


leading factories in the field of manufacturing air-conditioning
outlets and air conditioned duct accessories and parts. Our
products have been installed in many distinguished
governmental and private projects in the Kingdom of Saudi
Arabia and several Gulf States as well as other Arab countries.
Our products have won many approvals from various sectors,
such as health, education, airports and others.

The research and development projects ongoing at our factory


have made us more flexible, versatile and capable to fulfill the
needs of the market.

Our branches in every major city in the Kingdom (Riyadh,


Jeddah and Dammam) made us closer to our customers and
better able to meet their demands and work with them side by
side to overcome all the technical and logistical problems that
may occur. Also that we are in close contact with the different
engineering offices enriched our technical capabilities and
customer confidence in our services.
Organization Chart
AL
-R

Location
IY
AD
H
EA
N
ST
ER
E N
(2 XIT RI
nd 1 NG
I.C 6 RO
SEVENTH ) AD
RABIA POWER PLANT EX
HOSPITAL T.
(N
EW
OL
D AL
H AL -K
-K HA
H AR RJ
J
RIYADH FURNITURE RD
RD RT
F INDUSTRIES )

82
o.1
tN
ee
Str
RABIE AL
TAKYEEF

SHAWAYA
HOUSE AL
SABIC -K
TECHNOLOGY
HA
RJ

(2
n E EA
Ci d In XIT ST
ty) du 1
str 6 ER
ial N
RI
NG
AL
RO -K
HA
SEVENTH
AD RJ
7

EX
P.

POWER PLANT
T.
P.

(N
EW
AL
-K
HA
RJ
St R D)
re
e t6
1

St
re
RIYADH FURNITURE
et
No INDUSTRIES
RT .75
F
2
18
et
re
St

RABIE AL TAKYEEF
St FACTORY
re
et
20
1
6
18
et
re
St

OL
D
AL
-K
HA SHAWAYA
RJ HOUSE
RD

GPS Coordinates

24.558833, 46.886611

Contact
Riyadh (Head Office) : Tel:+966 (11) 4982414 Fax.+966 (11) 2082786
P.O.Box- 390982 Riyadh,11365, Kingdom of Saudi Arabia.
Physical Add-4114 Second Industrial Area,Riyadh,14332-6676,Kingdom of Saudi Arabia.
Jeddah Branch : Tel:+966 (12) 6394300 Fax.+966 (12) 6394300
Dammam Branch : Tel:+966 (13) 8470488 Fax.+966 (13) 8470499
www.rabie-ac.com
2. Approvals
A. Approval list
B. Sample of Approvals
Copies
RABIE Approvals List
Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic field
160 27/04/2015 Delta Consulting Engineers Al-Jouf University Faculty members Housing Ministry Of Higher Education Air Outlets
153 01/05/2015 Imar Urban Consultants King Faisal University Engineering College Ministry Of Higher Education EB
Female Medicine College -
152 29/12/2014 Emaar construction consulting University of Dammam Ministry Of Higher Education Air Outlets
University of Dammam
Al-Fadhli Consulting and
155 28/12/2014 Dammam University College of Education - Girls Ministry Of Higher Education EB
Engineering
Al-Imam Muhammad Ibn Saud
8 30/11/2014 TYPSA - - VCD
Islamic University
Al-Fadhli Consulting and
148 19/10/2014 Dammam University Girls Education College Ministry Of Higher Education VCD, FD
Engineering
141 09/11/2014 Zuhair Fayez Partnership King Khalid University Academic Male Campus Ministry Of Higher Education RAV
140 09/11/2014 Zuhair Fayez Partnership King Khalid University Academic Male Campus Ministry Of Higher Education RSA
‫القاعات الدراسية العاجلة منطقة‬
134 17/03/2014 ‫ردهات لالستشارات الهندسية والمعمارية‬ ‫جامعة الملك خالد‬ Ministry Of Higher Education CD
‫عسير‬
23 03/07/2014 Saudi Consulting Services King Khalid University - Ministry Of Higher Education General
12 03/06/2014 - - - Ministry Of Higher Education General
6 03/02/2014 - ‫إسكان أعضاء هيئة التدريس‬ ‫المرحله األولى‬ Ministry Of Higher Education RSA
138 07/10/2013 Saudi Consulting Services ‫جامعة الملك خالد‬ - Ministry Of Higher Education FD
Construction Of
King Fahd University Of Petroleum
11 20/06/2013 - Preparatory Year Class Ministry Of Higher Education Air Outlets
& Minerals
Room Building
125 25/05/2013 Saud Consult King Khalid University - Ministry Of Higher Education HF

RABIE Approvals List 1/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
131 field
28/05/2012 Khatib & Alami ‫جامعة تبوك‬ ‫إسكان الطالب‬ Ministry Of Higher Education Air Outlets
2 16/03/2012 BURO HAPPOLD Al-Faisal University Conference Center - CD, PB
4 03/03/2012 BURO HAPPOLD Al-Faisal University Phase 2 - LBG
3 03/03/2012 BURO HAPPOLD Al-Faisal University Conference Center - LSD
‫مشاريع إسكان أعضاء هيئة التدريس بمحافظة‬
9 03/01/2012 Saudi Consulting Services Stage-B Ministry Of Higher Education RAV
‫الخرج‬
24 28/01/2012 ‫ردهات لالستشارات الهندسية والمعمارية‬ ‫جامعة نجران‬ - Ministry Of Higher Education General
‫مشاريع إسكان أعضاء هيئة التدريس بمحافظة‬
10 24/01/2012 Saudi Consulting Services Stage-A&B Ministry Of Higher Education LSD, LBG, FAL
‫الخرج‬
16 10/04/2011 Zuhair Fayez Partnership King Khalid University - Ministry Of Higher Education FD
Faculty Of Education - Male
5 09/11/2011 Saud Consult Taibah University Ministry Of Higher Education LBG, RAV
Campus - B13
18 26/06/2011 Zuhair Fayez Partnership King Khalid University - Ministry Of Higher Education VCD
1 15/06/2011 Zuhair Fayez Partnership ‫جامعة الدمام‬ ‫مبنى كلية العمارة والتخطيط‬ Ministry Of Higher Education JD
22 06/06/2011 Zuhair Fayez Partnership King Khalid University - Ministry Of Higher Education VCD
14 17/05/2011 amcde Al-Faisal University ‫سكن أعضاء هيئة التدريس‬ - General
‫الفصول الدراسية العاجلة للكليات‬
34 15/05/2011 - ‫جامعة أم القرى‬ Ministry Of Higher Education FD
‫الطبية‬
‫الفصول الدراسية العاجلة للكليات‬
33 15/05/2011 - ‫جامعة أم القرى‬ Ministry Of Higher Education RSA
‫الطبية‬
‫الفصول الدراسية العاجلة للكليات‬
32 15/05/2011 - ‫جامعة أم القرى‬ Ministry Of Higher Education Air Outlets
‫الطبية‬
‫الفصول الدراسية العاجلة للكليات‬
35 05/10/2011 - ‫جامعة أم القرى‬ Ministry Of Higher Education RAV
‫الطبية‬

RABIE Approvals List 2/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
20 field
24/04/2011 Zuhair Fayez Partnership King Khalid University - Ministry Of Higher Education FD
21 23/04/2011 Zuhair Fayez Partnership King Khalid University - Ministry Of Higher Education FD
19 23/04/2011 Zuhair Fayez Partnership King Khalid University - Ministry Of Higher Education FD

40 04/10/2011 Dar Al-Handasah KSUHS In Jeddah College Of Nursing Building National Guard LSD, CD

17 29/03/2011 - King Faisal University Al-Hassa Campus - VCD


‫كلية العمارة والتخطيط بالمدينة‬
38 31/01/2011 Zuhair Fayez Partnership University Of Dammam Ministry Of Higher Education General
‫الجامعية‬
Princess Noura Bint Abdulrahman
27 23/01/2011 Dar Al-Handasah - Ministry Of Higher Education GSH-W
University
Princess Noura Bint Abdulrahman
28 20/01/2011 Dar Al-Handasah - Ministry Of Higher Education GSH-W
University
30 01/11/2011 Emaar construction consulting Research Center B 16 - General
‫مبنى كلية العمارة و التخطيط‬
36 14/12/2010 - ‫جامعة الدمام‬ ‫ومشروع مبنى المكتبة بالمقر الدائم‬ Ministry Of Higher Education PB
‫لجامعة الدمام‬
29 27/10/2010 Emaar construction consulting Research Center B 16 - FSD, PB, RSA
13 10/10/2010 - Al-Faisal University - - Air Outlets
37 09/01/2010 Emaar construction consulting ‫جامعة اإلحساء‬ ‫مشاريع بالمدينة الجامعية باإلحساء‬ Ministry Of Higher Education LSD
Al-Imam Muhammad Ibn Saud
7 30/08/2010 TYPSA South Car Parking Area Ministry Of Higher Education AG
Islamic University
Princess Noura Bint Abdulrahman
26 07/08/2010 Dar Al-Handasah - Ministry Of Higher Education AG, CD
University
Princess Noura Bint Abdulrahman
25 25/05/2010 Dar Al-Handasah - Ministry Of Higher Education AG, CD
University

RABIE Approvals List 3/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
41 field
27/04/2010 Dar Al-Handasah
King Saud Bin Abdelaziz University
- National Guard Air Outlets
For Health Sciences
King Saud Bin Abdelaziz University
39 27/04/2010 Dar Al-Handasah - National Guard Air Outlets
For Health Sciences
Construction Of Faculty Of Social Ministry Of Higher Education In
31 25/02/2010 Saudi Consulting Services - FD
Studies Building In Al-Khari Riyadh
King Saud Bin Abdul-Aziz
42 27/12/2009 Dar Al-Hadassah - National Guard Air Outlets
University For Health Sciences
43 15/10/2009 Zohar Fayez Partnership King Faisal University ‫كلية العماره والتخطيط‬ Ministry Of Higher Education General
Male Administration
15 29/07/2008 - Al-Faisal University Building Interior - LSD
Modification
National Center For Assessment In
44 27/03/2008 - - Ministry Of Higher Education Air Outlets
Higher Education
SAK Consultant (Suliman Abdullah College of Basic Medical Science
173 12/04/2015 - University of Dammam AD, FD
alKhuraijy) Building
Faculty of Medicine - Dammam
174 29/06/2015 Imar Urban Consultants - University of Dammam STL
University
College of Sciences and
179 30/03/2014 Al Shabanat Consulting Office Shaqraa University - Air Outlets
Literature
189 30/01/2016 Saudi Consult Sport City - King Khaled University RAV
195 01/08/2017 AD Engineering Co. NAJRAN HOSPITAL UNIVERCITY - Ministry Of Higher Education RAV
Applied science college in Shaqra
198 16/10/2017 Not Mentioned - Ministry Of Higher Education RAV
university
201 20/12/2017 Saudi Consult Management business college - Tabuk University FD

RABIE Approvals List 4/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
206 field
01/03/2018 Saudi Consult Social Observation House - Ministry of Social Affairs General
Al-Imam Mohamed bin Saud
207 01/06/2018 Takweenat Consultant Educational building - General
University
218 20/01/2018 Saudi Consult ‫كليه اداره االعمال‬ - Ministry Of Higher Education FD
224 21/01/2018 Saudi Consult ‫مستشفى جامعة الحدود الشمالية‬ - Ministry Of Higher Education General
225 21/01/2018 Beeah Consulting ‫جامعة الحدود الشمالية‬ - Ministry Of Higher Education General
228 21/01/2018 AD Engineering Co. NAJRAN HOSPITAL UNIVERCITY - Ministry Of Higher Education RAV
232 25/01/2018 Al-Rokn consulting office ‫المباني المساندة بجامعة المجمعة‬ - Ministry Of Higher Education General
251 17/02/2018 Project management ‫الجامعة االسالمية بالمدينة المنوره‬ - Ministry Of Higher Education VCD, FD
AL RABIAH CONSULTING
282 04/05/2018 Girls AUDITORIUM COLLEGE - Ministry Of Higher Education FSD
ENGINEER
283 04/05/2018 Saudi Consult Management business college - Tabuk University FSD
Technical And Vocational
284 04/05/2018 Not Mentioned Technical collage balqarn - General
Training Corporation
Medical College - Prince Sattam Bin
298 14/10/2018 Al Shabanat Consulting Office - Ministry Of Higher Education RAV
Abdulaziz University

Medical field
Development of Intensive
162 27/04/2015 Aral Eng. Consultant office King Fahd Specialist Hospital Ministry Of Health Riyadh RAV
Care

165 04/08/2015 Khatib & Alami 500 Bed Prototype Hospital - Jizzan - Ministry Of Health Riyadh PB

Obstetrics Gynecology and Pedric


164 04/08/2015 Khatib & Alami - Ministry Of Health Riyadh PB
Hospital - Jeddah
167 21/03/2015 Otaishan consulting engineers Procare Riaya Hospital Expansion - Procare Riaya Hospital RAV

RABIE Approvals List 5/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
156 field
03/09/2015 Otaishan consulting engineers Procare Riaya Hospital Expansion - Procare Riaya Hospital VCD, FD, BDD
166 03/04/2015 Otaishan consulting engineers Procare Riaya Hospital Expansion - Procare Riaya Hospital Air Outlets
Finishing works of IT
157 16/02/2015 - King fahd military medical complex Ministry of Defence LSD, CD, RCD, DV, RAV
Building
‫مركز األمير نايف الطبي ألمراض الكلى وديلزة‬
51 25/01/2015 Khatib & Alami - Ministry Of Interior FAL
‫الدم‬
‫مركز األمير نايف الطبي ألمراض الكلى وديلزة‬
50 25/01/2015 Khatib & Alami - Ministry Of Interior Air Outlets
‫الدم‬
Development of intensive
163 01/06/2015 Arkal eng.Consultant office King Fahd Specialist Hospital Ministry Of Health Riyadh VCD, PB
care
48 03/07/2014 Project management ‫توسعة مبنى مديرية الصحه بالشرقيه‬ Ministry Of Health Air Outlets
The World Centre for engineering
52 19/10/2011 ‫ سرير‬200 ‫مستشفى الصحه النفسيه بحائل سعة‬ - Ministry Of Health Air Outlets
consultancy
54 22/03/2011 Bin Jubir Engineers Consultant ‫إنشاء مستشفى عرفات العام بمكة المكرمة‬ - Ministry Of Health Air Outlets
45 23/01/2011 Khatib & Alami New Riyadh National Hospital B1-2 And B3 Building - General

59 17/10/2010 East Consulting Engineering Center Madinah Hospital - Ministry Of Health Air Outlets

46 05/02/2010 Khatib & Alami New Riyadh National Hospital - - General


Medical Stores Electromechanical
49 04/12/2010 - - Ministry Of Health Air Outlets
Works At King Fahad Medical City
200 ‫مستشفى النساء والوالدة بالخرج سعة‬
53 01/10/2010 The Saudis architects - - Air Outlets
‫سرير‬
55 10/01/2009 Project management - ‫مديرية الشؤون الصحية‬ General
56 15/08/2009 - ‫إنشاء مستشفى البرج الطبي بجازان‬ - - CD, FD

RABIE Approvals List 6/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
47 field
17/05/2009 Al-Shabanat Eng. Consultant Office ‫إنشاء وتطوير مستشفى جنوب الرياض‬ - - AG

58 11/12/2007 Al-Shabanat Eng. Consultant Office ‫مركز التأهيل الشامل بالخرج‬ - - AG

57 11/06/2007 Project management ‫مستشفى السليل‬ ‫ سرير‬14 ‫مركز غسيل كلوي‬ - General
193 10/09/2017 Khatib & Alami Al Jummom Hospital - Ministry Of Health Air Outlets
196 28/10/2014 Al Mukhtass Consulting Office King Faisal Hospital - Ministry Of Health General
209 15/01/2018 THE SPECIALIST GROUP KFH - BURAIDA - Ministry Of Health Air Outlets
220 20/01/2018 Khatib & Alami al jummom hospital - Ministry Of Health General
223 20/01/2018 THE SPECIALIST GROUP KFH - BURAIDA - Ministry Of Health VCD, FD
239 27/01/2018 - KFSH - Ministry Of Health VCD
241 27/01/2018 - KFSH AND R C - Ministry Of Health General
AL FOUZ FOR ENGINEERING
254 17/02/2018 ‫انشلء مركز طب االسنان التخصصي بالقطيف‬ - Ministry Of Health General
CONSULTANT
256 20/02/2018 Khatib & Alami AL MEQAT HOSPITAL - Ministry Of Health VCD, FD
262 03/03/2018 Khatib & Alami Al jummom hospital - Ministry Of Health FD
Rehabilitation of OB Gyne Building -
265 03/07/2018 Not Mentioned - Ministry Of Health Air Outlets
PSMMC
Rehabilitation of OB Gyne Building -
266 03/07/2018 Not Mentioned - Ministry Of Health General
PSMMC
Arch Center Consulting Architects
287 15/05/2018 SPECIALTY HOSPITAL - - VCD, FD, DAD
and Engineers
Rehabilitation Design of Jazan
288 15/05/2018 Saudi Consult - Ministry Of Health General
General Hospital

RABIE Approvals List 7/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
294 field
18/09/2018 Khatib & Alami AL MEQAT HOSPITAL - Ministry Of Health STL
Arch Center Consulting Architects
300 23/10/2018 SPECIALTY HOSPITAL - - RSA
and Engineers

Military field
Const.of nurses accommodation
142 06/09/2014 - - Ministry of Defence RCD, STL
kaab-afh
‫كلية األمير سلطان العسكرية للعلوم الصحية‬
136 20/05/2014 - - National Guard Air Outlets
‫بالظهران‬
161 15/02/2014 - Prince Sultan Air Base Observation Facilities Saudi Royal Air forces CD
‫إنشاء ثالث كتائب قاعدة اإلمداد والتموين‬
60 15/06/2011 Project management - - RSA
‫وحدة إشارة منطقة الرياض‬
61 01/01/2011 Otaishan consulting engineers ‫قيادة لواء وكتيبتين مشاه‬ - - LSD
122 14/02/2010 - ‫كلية الملك فيصل الجويه‬ ‫صالة التخرج‬ - LSD
‫المرحلة الثانية صالة الملعب وصالة‬
89 03/03/2014 Project management ‫مدينة تدريب األمن العام بمنطقة مكة المكرمة‬ ‫المسبح والصالة الرياضية ومبنى‬ Ministry Of Interior Air Outlets
‫الرماية وصالة الطعام والمسجد‬
90 15/08/2011 Dar Al-Handasah Correctional Facilities - Ministry Of Interior Air Outlets
87 04/04/2011 Khatib & Alami ‫مباني قوة وحدة األمن والحماية‬ - Ministry Of Interior Air Outlets
86 04/03/2011 Khatib & Alami ‫مباني قوة وحدة األمن والحماية‬ - Ministry Of Interior FD
‫إنشاء معسكر قوات الطوارئ الخاصة بمحافظة‬
124 23/06/2010 Project management - - LSD
‫الطائف‬
LSD, LBG, AG, DG, EC,
85 25/01/2010 Saudi Consulting Services Governmental Building On Mjardh - Ministry Of Interior
CD
The engineering Union Saudi Governmental Building On
62 25/01/2010 - Ministry Of Interior CD
Arabia company Qurayyat

RABIE Approvals List 8/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
83 field
11/09/2009 Saudi Consulting Services Abu Al-Saud Police Station - Ministry Of Interior Air Outlets
Regional Principality Complex In
123 11/08/2009 Saudi Consulting Services - Ministry Of Interior AG, DG, VCD, FD
Jazan
LSD, LBG, AG, AGF,
84 26/07/2008 Saudi Consulting Services Bisha Governmental Building - Ministry Of Interior
DG, CD, RCD, DV
88 02/04/2008 Khatib & Alami ‫ الرياض‬- ‫وحدة دفاع مدني ضرما‬ - Ministry Of Interior Air Outlets
Royal Commission for jubail
145 29/06/2014 Naba International Police Station - Air Outlets
and yanbu
Royal Commission for jubail
146 22/06/2014 Naba International Police Station - FD
and yanbu
Royal Commission for jubail
147 18/06/2014 Naba International Police Station - STL
and yanbu
172 13/04/2015 Archen Engineering National Information Center - Ministry Of Interior FD
175 12/12/2013 Khatib & Alami Training Section - Wadi Aldwaser - Ministry of Defence Air Outlets
Const.of Nurses
185 09/06/2014 - - Ministry of Defence RCD, STL
Accommodation,Kaab-AFH
Expansion of Hospital and
Construction of Rehablitation and
186 18/10/2015 Al Naeem Consulting office - National Guard Health Affairs RSA
Hemodialysis Centers at iabfh
dammam-Ksa
Expansion of Hospital and
Construction of Rehablitation and
188 21/07/2015 Al Naeem Consulting office - National Guard Health Affairs CD, RSA
Hemodialysis Centers at iabfh
dammam-Ksa
197 15/10/2017 Khatib & Alami ‫المباني المسانده الدوادمي‬ - Ministry of Defence RSA
200 26/11/2017 Khatib & Alami ‫المباني المسانده الدوادمي‬ - Ministry of Defence VCD, FD

RABIE Approvals List 9/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
226 field
21/01/2018 Khatib & Alami ‫المباني المسانده الدوادمي‬ - Ministry of Defence General
227 21/01/2018 Khatib & Alami ‫المباني المسانده الدوادمي‬ - Ministry of Defence General
234 27/01/2018 Khatib & Alami ‫المباني المساندة الدوادمي‬ - Ministry of Defence General
Proger Engineering and
240 27/01/2018 KAP4 - Ministry Of Interior STL
Management
242 27/01/2018 Khatib & Alami ‫قاعدة عسكرية بالدوادمي‬ - Ministry of Defence General
257 28/02/2018 Gesbau 2ace KAP 5 - Ministry Of Interior General
258 03/01/2018 - MAKKAH MEDICAL CENTER - Ministry of Defence Air Outlets
259 03/01/2018 - MAKKAH MEDICAL CENTER - Ministry of Defence Air Outlets
260 03/01/2018 - MAKKAH MEDICAL CENTER - Ministry of Defence RSA, RAV
Rehabilitation of OB Gyne Building -
263 03/07/2018 Project management - Ministry of Defence General
PSMMC
Rehabilitation of OB Gyne Building -
264 03/07/2018 Project management - Ministry of Defence General
PSMMC
273 19/03/2018 Khatib & Alami KAP 1 - Ministry Of Interior General
Proger Engineering and
276 04/03/2018 KAP4 - Ministry Of Interior STL
Management
277 04/03/2018 Gesbau 2ace KAP-5 - Ministry Of Interior Air Outlets
289 07/02/2018 - ALHADA HOSPITAL - Ministry of Defence General
293 09/12/2018 NKY Architects and Engineers KAP 2D - Riyadh - Ministry Of Interior Air Outlets
296 10/03/2018 Archen Engineering DIPLOMATIC QUARTER RIYADH - Ministry Of Interior Air Outlets
299 22/10/2018 NKY Architects and Engineers KAP 2 - Ministry Of Interior Air Outlets

RABIE Approvals List 10/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic field CLSD, CLBG, PAG, SEC-


AR, LSD, LBG, AG, DG,
295 29/09/2018 Gesbau 2ace KAP-5 - Ministry Of Interior
EC, CD, RCD, JD, DV,
STL, VCD, FD, PB, RSA

Technical training field


Technical And Vocational
159 09/01/2014 Al-Jaweini Consulting Engineers Trainers High Institute-Jeddah - FD, PB
Training Corporation
Technical And Vocational
158 09/01/2014 Al-Jaweini Consulting Engineers Trainers High Institute-Jeddah - Air Outlets
Training Corporation
Ibrahim Al-Zamandar Consulting Technical And Vocational
144 13/08/2014 ‫كلية التقنية للبنات بالرياض‬ - RAV, REH
Office Training Corporation
‫مكتب أسس لإلستشارات الهندسية مهندسون‬ ‫إسكان للمدربين والمتدربين لبرنامج جنرال‬ Technical And Vocational
135 19/05/2014 - Air Outlets
‫ومعماريون‬ ‫موتور بالرياض‬ Training Corporation
Technical And Vocational
79 03/01/2014 Office space consultants ‫معهد التدريب المهني حقل‬ - Air Outlets
Training Corporation
Technical And Vocational
78 03/01/2014 Khozam Consulting Engineers ‫معهد التدريب المهني بوادي الدواسر‬ - Air Outlets
Training Corporation
Technical And Vocational
76 03/01/2014 Consultants corner desk ‫معهد التدريب المهني بالنماص‬ - General
Training Corporation
Technical And Vocational
73 03/01/2014 Al-Jaweini Consulting Engineers ‫معهد التدريب المهني بالشنان‬ - Air Outlets
Training Corporation
Technical And Vocational
72 03/01/2014 Al-Jaweini Consulting Engineers ‫معهد التدريب المهني بالرس‬ - Air Outlets
Training Corporation
Technical And Vocational
71 03/01/2014 ‫مكتب عبد الرحمن المبارك لإلستشارات الهندسية‬ ‫معهد التدريب المهني بالخفجي‬ - LSD
Training Corporation

RABIE Approvals List 11/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
68 field
03/01/2014 Anwar Foundation Duc co. ‫إنشاء مركز التدريب المهني بسجن نجران‬ -
Technical And Vocational
Air Outlets
Training Corporation
Technical And Vocational
65 03/01/2014 Al-Rai Engineering Consultants ‫إنشاء الكلية التقنية بنين بالقويعية‬ - Air Outlets
Training Corporation
Technical And Vocational
64 03/01/2014 Office code engineering consultants ‫استكمال معهد التدريب المهني شفراء‬ - VCD
Training Corporation
‫صالة متعددة اإلستخدامات لألنشطة‬ Technical And Vocational
132 26/02/2014 House engineering consultants ‫الكلية التقنية بالجوف‬ LSD
‫الطالبية‬ Training Corporation
Technical And Vocational
75 27/11/2011 Project management ‫معهد التدريب المهني بالنعيرية‬ - Air Outlets
Training Corporation
Technical And Vocational
66 23/08/2010 East Consulting Engineering Center ‫إنشاء الكلية التقنية بنين بمحايل عسير‬ - Air Outlets
Training Corporation
Technical And Vocational
67 08/11/2010 Al-Jaweini Consulting Engineers ‫إنشاء كلية السياحة والفندقة بالرياض‬ - General
Training Corporation
VCD, FD, FSD, PB,
Technical And Vocational
69 04/06/2010 Consultants corner desk ‫معهد التدريب المهني بالجوف‬ - RSA, RAV, REH, PRD,
Training Corporation
DAD, OBD, BFD
Technical And Vocational
63 02/12/2010 Khozam Consulting Engineers ‫استبدال معهد التدريب المهني بوادي الدواسر‬ - Air Outlets
Training Corporation
Technical And Vocational
77 24/01/2010 Khozam Consulting Engineers ‫معهد التدريب المهني برنية‬ - Air Outlets
Training Corporation
70 16/01/2010 Khozam Consulting Engineers ‫معهد التدريب المهني بالحقو‬ - - General
Technical And Vocational
74 06/07/2009 Arab engineers architects ‫معهد التدريب المهني بالمهد‬ - Air Outlets
Training Corporation
Higher Education Fund
184 11/11/2015 Saudi Consulting Services Jazan Hotel and diving center - FAL
Kingdom of Saudi Arabia

RABIE Approvals List 12/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
190 field
03/11/2015 - ‫الكلية التقنية للبنين بالدمام‬ ‫مشروع انشاء مباني اضافية‬
Technical And Vocational
RAV
Training Corporation
LSD, LBG, AG, AGF,
Technical College for Girls - Khamis Technical And Vocational
191 28/12/2015 Al Rai Engineering Consultants - DG, EC, AD, CD, RCD,
Mashit Training Corporation
JD, DV
technical industral instittute in Technical And Vocational
194 16/10/2017 Al-Tawfeeq consulting office - General
gazala city Training Corporation
technical industral instittute in Technical And Vocational
199 16/10/2017 Al-Tawfeeq consulting office - General
gazala city Training Corporation
Ibrahim Al Zamandar Consulting Technical And Vocational
219 20/01/2018 TECHNICAL COLLEGE - Air Outlets
Office Training Corporation
Tower Top for engineering Technical And Vocational
235 27/01/2018 ‫استكمال الكلية التقنية بالنماص‬ - General
consulting Training Corporation
Cooperative Office for Civil MINISTRY OF LABOUR SHQRAA Human Resources
267 15/03/2018 - RAV
Engineering Consulting BULDING Development Fund
Cooperative Office for Civil MINISTRY OF LABOUR SHQRAA Human Resources
268 15/03/2018 - RAV
Engineering Consulting BULDING Development Fund
Cooperative Office for Civil MINISTRY OF LABOUR SHQRAA Human Resources
269 15/03/2018 - RAV
Engineering Consulting BULDING Development Fund
Cooperative Office for Civil MINISTRY OF LABOUR SHQRAA Human Resources
270 15/03/2018 - RAV
Engineering Consulting BULDING Development Fund
Cooperative Office for Civil MINISTRY OF LABOUR SHQRAA Human Resources
271 15/03/2018 - RAV
Engineering Consulting BULDING Development Fund
Cooperative Office for Civil MINISTRY OF LABOUR SHQRAA Human Resources
272 15/03/2018 - RAV
Engineering Consulting BULDING Development Fund

RABIE Approvals List 13/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic field
Other
LSD, LBG, AG, AGF,
DG, EC, AD, CD, RCD,
Tawuniya Regional Office BLDG. Al-
102 19/05/2011 Advanced Construction Center - - JD, DV, FAL, GSH-W,
Khobar
STL, VCD, FD, FAU,
LSDC, LBGC
Simal Design Associates Al-Nahda Office Commercial
92 18/01/2011 - - FD
Associated Consulting Eng Building
99 21/03/2010 - View Tower - - AG
98 21/03/2010 - Insan Tower - - CD
Al-Tameer Co. Residential Palace
94 20/03/2010 RBT Energistics International - - FAL
Riyadh
LSD, LBG, AG, AGF,
DG, EC, AD, CD, RCD,
Upstream Professional
100 15/03/2010 - - Saudi Aramco JD, DV, FAL, GSH-W,
Development Center
STL, VCD, FAU, LSDC,
LBGC
93 28/02/2010 Takweenat Consultant Al-Tamaiouz Office Tower - - LSD, LBG, RCD, PB
103 27/07/2009 Project management ‫مختبر المكافحة الحيوية المركزي بالرياض‬ - Ministry of Agriculture General
108 19/07/2009 ‫مكتب محمد النعيم لإلستشارات الهندسية‬ ‫إنشاء مجمع الدوائر الشرعية بجازان‬ - Ministry of Justice Air Outlets
Al-Wassil Commercial Tower On
96 14/06/2009 - - - FAL
King Fahed Road
106 19/03/2009 Beeah Consulting ‫المقر الجديد لوزارة التربية والتعليم‬ - - Air Outlets
95 14/03/2009 Takweenat Consultant Al-Tamayoz Office Tower - - Air Outlets
109 28/02/2009 - Darat King Abdul-Azizi extension - - Air Outlets

RABIE Approvals List 14/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
107 field
25/11/2008 Engineering consulting Office ‫إنشاء مبنى الزكاة والدخل بالدمام‬ - Ministry of Finance Air Outlets
105 31/05/2008 - ‫إنشاء مستودعات لصيانة التموين الرئيسي بتبوك‬ - Ministry of Defence STL
HRH Prince Abdul-Aziz Bin Saud
97 04/09/2008 Mohamed Harasani Architect - - LSD
Bin Naif Riyadh
Al-Jeraisy Complex - Huda Johara
91 14/11/2007 Omrania Consulting - - LSD, LBG, DV
Villas
‫تشغيل وصيانة ونظافة المرحلة الثانية لمنطقة‬ High Commission for
104 10/10/2007 - - General
‫قصر الحكم‬ Development of Riyadh
101 23/06/2007 The Saudi Architects Sheik Offices Riyadh - - Air Outlets
General Authority of Civil
113 03/05/2014 Khatib & Alami ‫تطوير مطار نجران‬ - Air Outlets
Aviation
112 16/09/2010 - King Khalid International Airport - - LSD

80 03/06/2013 Ealam Al-Issa Consulting Engineers Rocco Forte Hotel And Residence - - FD

81 30/11/2010 Dar Al-Omran Consultants Intercontinental Hotel - Riyadh Main Lobby Renovation - RSA
Dr. Mohammed Almalik Office
82 21/04/2008 Khuzama - - LSDC
Engineering Consultant
Renovation of office space 1st 2nd
168 27/04/2015 - - Saudi Aramco CD, FD, RAV
3rd floor west ratanura
171 02/10/2015 Knos Architects and Interiors Zahid Tractor Facility - Dammam - - Air Outlets
Arc Center Consulting Architects Residential units at diplomatic
170 22/12/2014 - Al-Akaria Air Outlets
and Engineers quaters Riyadh
Arc Center Consulting Architects Residential Units at diplomatic
151 22/12/2014 - Al-Akaria Air Outlets
and Engineers quarters Riyadh

RABIE Approvals List 15/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
169 field
17/12/2014 Cosmos E and Design Directions Dareen -MUDP Jubail KSA -
Royal Commission for jubail
RAV
and yanbu
154 15/12/2014 Samsung Al-Rajhi Bank - - Air Outlets
Group 6 of Educational Building in
149 11/06/2014 Otaishan consulting engineers - Tatweer Al-Mabani General
Riyadh
Vendor list-Eastern Province Ministry of Municipal and Rural
143 15/09/2014 - - General
Municipality Affairs
Development engineering General Presidency of youth
139 07/10/2014 Al Rawda Club Al Ahsaa - Air Outlets
consultants welfare
137 16/06/2014 - Jupail Electrical Work - General Organization of ports AG, CD, VCD
133 04/08/2014 Suhaimi Design Al-Ansari Compound 2 - - Air Outlets
130 22/02/2014 Khatib & Alami Jabal Omar Development - - RSA
Al-Etquan Consulting Engineering Governmental Complex at Makkah-
150 17/02/2014 - Ministry of Finance General
office M.O.F
Development engineering
128 01/12/2014 ‫إنشاء مبنى دار المالحظة اإلجتماعية بنجران‬ - - Air Outlets
consultants
‫إنشاء مبنى المختبر المركزي للمديرية العامة‬
127 01/04/2014 Khatib & Alami - - Air Outlets
‫للمياه بمنطقة عسير‬
126 10/09/2013 - ‫إنشاء خمسة مدارس‬ - Ministry of Education Air Outlets
117 19/09/2013 - National Society For Human Rights - - AG, VCD
120 14/02/2011 Otaishan consulting engineers Saudi Industrial - - LSD
121 12/04/2010 Saud Consult King Abdullah Financial District - King Abdullah Economic City AG
Ministry Of Foreign Affairs
119 12/01/2010 Delta Consulting Engineers - Ministry Of Foreign Affairs Air Outlets
Building - At Al-Dammam

RABIE Approvals List 16/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
118 field
28/08/2010 East Consulting Engineering Center King Abdullah Park In Riyadh -
Ministry of Municipal and Rural
AG
Affairs

115 26/05/2010 - National Commercial Bank King Khalid Road Buraidah - RAV

116 17/07/2008 - National Commercial Bank - - Air Outlets


114 24/07/2007 Mohamed Harasani Architects Al-Rajhi Bank Airport Branch Al Rajhi Bank Air Outlets
110 13/05/2012 - Mitsubishi Substations - National Grid SA AG
111 16/08/2006 - Sharourah PS Extension - Saudi Electricity Company LSD
Worley Parsons Resources and
176 11/04/2015 Construction Of Marafiq Corporate - Marafiq General
Energy
177 07/08/2015 HCO KMC-Jubail - Baitak Company General
Princess Sarah Bint Ahmed Al-
High Commission for
178 11/01/2015 Dar Al Omran Consultants Sudairy Center for Feminine - Air Outlets
Development of Riyadh
Research
Arabian Consulting Engineering General Presidency of youth
180 29/12/2014 Dhamak Sport Club - CD
Services welfare
Arabian Consulting Engineering General Presidency of youth
181 14/05/2012 Dhamak Sport Club - AG
Services welfare
Arabian Consulting Engineering General Presidency of youth
182 24/12/2014 Al-Derh club - Dawadmy - CD
Services welfare
Sulaiman A.Al Rajhi Investment
183 17/12/2015 Imar Urban Consultants Shaza Riyadh G14 - Air Outlets
Co.
Madinat Al-Jubail Al-Sinaiyah Royal Commission for jubail
187 17/11/2015 - - BDD
Construction Department and yanbu
192 22/02/2016 - Yasmeen Mall - Fare Construction FD

RABIE Approvals List 17/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
129 field
02/09/2014 Al Wasat Engineering Office Elegance Tower - - AG, VCD, FD, FSD
202 31/12/2017 Saudi Consult Social Observation House - Ministry of Social Affairs CLSD, AG, CD
203 31/12/2017 Saudi Consult Social Observation House - Ministry of Social Affairs CLSD, AG, CD
204 31/12/2017 Saudi Consult Social Observation House - Ministry of Social Affairs CLSD, AG, CD
205 31/12/2017 Saudi Consult Social Observation House - Ministry of Social Affairs CLSD, AG, CD
Saudi Industrial Property LSD, LBG, CD, RCD,
208 01/06/2018 Dar Al Riyadh ‫محطة حريق‬ -
Authority VCD, FSD
210 17/01/2018 Saudi Diyar Consultant QURTOBA COMPOUND - Solidere CLSD, FD
211 17/01/2018 Saudi Diyar Consultant QURTOBA COMPOUND - Solidere CLSD, STL
212 17/01/2018 - ASAAD PROJECTS - - AD
213 18/01/2018 Al Jaweini Consulting Engineers ‫مكاتب عمل ومكاتب شئون اجتماعيه‬ - Ministry of Labour General
214 18/01/2018 Advanced Construction Center ‫محاكم وكتابات العدل‬ - Ministry of Justice General
‫انشاء محاكم وكاتبات العدل بمنطقه المدينه‬
216 18/01/2018 Saudi Diyar Consultant - Ministry of Justice General
‫المنوره‬
217 18/01/2018 EHAF Consulting Engineers ‫منفذ الحديثة‬ - Ministry of Finance General
221 20/01/2018 ‫الهيكل العمراني‬ RADISON BLUE HOTEL - Chamber of Commerce Air Outlets
222 20/01/2018 ‫الهيكل العمراني‬ RADISON BLUE HOTEL - Chamber of Commerce RAV
229 21/01/2018 Hyder Consulting EC HARRIS - - General
230 01/10/2018 - Al-Munajem Building - Al Munajem Air Outlets
231 23/01/2018 Al Jaweini Consulting Engineers ‫مكاتب عمل ومكاتب شئون اجتماعيه‬ - Ministry of Labour General
236 27/01/2018 Abdullah al-saeed ‫التأهيل الشامل بريده‬ - Ministry of Social Affairs General
237 27/01/2018 Consultant of Consultants ‫برج مجدول‬ - Awtad Company VCD
238 27/01/2018 - SPIMACO Addwaeih - SPIMACO Addwaeih General

RABIE Approvals List 18/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
243 field
27/01/2018 Emaar construction consulting Shaza Hotel -
Sulaiman A.Al Rajhi Investment
General
Co.

LSD, LBG, AG, DG, CD,


244 02/01/2018 Khatib & Alami ANTARA COMPOUND - Antar Company
RCD, DV, FD, FSD

245 02/08/2018 ‫الهيكل العمراني‬ RADISON BLUE HOTEL - Chamber of Commerce VCD, FD, FSD
246 02/10/2018 Al Jaweini Consulting Engineers ‫مكاتب عمل ومكاتب شئون اجتماعيه‬ - Ministry of Labour General
General Authority of Civil
247 02/10/2018 Dar Al Riyadh abha airbort - Air Outlets
Aviation (GACA)
HAK Architectural and Engineering
248 17/02/2018 JEDDAH GATE - - VCD, FD, FSD
Consultants
HAK Architectural and Engineering
249 17/02/2018 JEDDAH GATE - - FD, FSD
Consultants
Almurjan Engineering Consulting
250 17/02/2018 POWER PLANT - - Air Outlets
Office
Cooperative Office for Civil ENRICHMENT EDUCATIONAL
252 17/02/2018 - - General
Engineering Consulting COMPLEX
253 17/02/2018 Khatib & Alami RIVIERA 1 COMPOND - - General
BINA ENGINEERING
255 17/02/2018 EWAN ALQYRWAN - - General
CONSULTANTING
Military Industries Bldg in Al -
261 03/01/2018 Project management - Military Industries Corporation General
Kharj
275 31/03/2018 - AL-Forsan School - Ajyalna Educational Company General
Dar Al Andalus Consulting
278 04/03/2018 National Guard IN ALHASSA - National Guard General
Engineers

RABIE Approvals List 19/20


Approval Approval
NO. Date
Consultant Project Sub-Project Owner Product

Academic
279 field
04/03/2018 EHAF Consulting Engineers tabuk park mall - - Air Outlets
280 04/03/2018 Khatib & Alami RIVIERA 1 COMPOND - - Air Outlets
281 04/03/2018 Hyder Consulting EC HARRIS - - STL
Royal Commission for jubail
285 22/04/2018 - ROYAL COMMISSION IN JUBAIL - General
and yanbu
FADHA ENGNEERING
286 14/05/2018 TATRA Trucks - Military Industries Corporation General
CONSALTANT
290 07/07/2018 Khatib & Alami Multi Bank Cash Center ( MBCC ) - Ministry of Finance Air Outlets
291 07/07/2018 J.K.Enterprise Ltd. RWAQ MALL QUOROBA - Roya Real Estate FD
STC NETWORK OPERATION
292 08/04/2018 Delta Consulting Engineers - STC General
CONTROL BUILDING PROJECT
Prince Khaled Al-Faisal Palace in
297 10/09/2018 Saudi Consult - - CLSD, CLBG, CD, STL
Zahban
Private Terminals in King Khaled General Authority of Civil
301 23/10/2018 Dar Engineering - RAV
Airport Aviation (GACA)
302 25/10/2018 Khatib & Alami Social Protection Unit in Madinah - Ministry of Social Affairs General
* Last update 13/11/2018
* "-" mark indicates data not mentioned on the approval copy.
* Any approval copy can be requested by "Approval NO."
* Following is a sample of approvals copies

RABIE Approvals List 20/20


RABIE AL TAKYEEF FACTORY vendor ID #10064078

6000001845 - GRILLE, HVAC, AIR CONDITIONING AND VENTI (Supply Air Grill/Return Air
Grill/Access Door)
6000013335 - (Insp) AIR VOLUME BOX, VAR OR CONST
6000013338 - (Insp) ATTENUATOR, SOUND, HVAC USE
6000001863 - (Insp) DAMPER, FIRE
6000001833 - MANUAL VOLUME DAMPER FOR HVAC, AHU
6000001850 - LOUVER
6000013334 - (Insp) DAMPER, VOLUME, MOTORIZED, PNEUMATIC
6000001835 - DIFFUSER, DUCTWORK
6000001864 - DAMPER: VOLUME, MANUAL, HVAC AIR DUCTING (pressure Relief
Damper/Back Draft Damper)
Saudi Aramco E-Reference No. 0000373

Registration Approval Letter


March 27, 2019

Attention : RABIE AL TAKYEEF FACTORY

CR Number : 1010211726
Country : Saudi Arabia
We are pleased to inform you that RABIE AL TAKYEEF FACTORY is now registered in the Saudi Aramco
Supplier Management System under Vendor Code No. 10064078, provided your company continues to meet
all relevant Saudi Arabian and Saudi Aramco standards.

This registration, however, should not be construed as a commitment by Saudi Aramco to procure from you.
Being registered as a supplier only grants your company the opportunity, along with other registered
sources, to respond to requests for submitting proposals in accordance with Saudi Aramco's established
policies and procedures. All procurement instruments including but not limited to service contracts, purchase
agreements, or purchase orders will be issued based on the name and address included in your commercial
registration (CR), as stated in your Supplier Registration.

Saudi Aramco wishes to remind you that being recognized as a supplier carries with it serious obligations
and responsibilities to act in a legal and ethical manner. We wish to remind you of the Saudi Aramco
Supplier Code of Conduct (SCOC) which you acknowledged. Failure to abide by the principles set forth in
the SCOC can result in adverse actions being taken by Saudi Aramco against you including suspension of
you as a supplier. Saudi Aramco also expects each of its suppliers to satisfy each of the requirements of any
procurement instrument which might be placed and to act responsibly and reliably as a supply chain supplier.

Material Suppliers should apply for Saudi Aramco Supplier Portal access by forwarding a request to
portal-registration@aramco.com. The Supplier Portal is the main electronic business tool used between
Saudi Aramco and its suppliers and serves to improve the flow and accuracy of key supply chain information.

For further information or assistance please contact the Saudi Aramco Supplier Help Desk by forwarding a
request to SupplierHelpDesk@aramco.com or via the unified call center +966 (13) 874-2222.

Dawoud Suliman Al Nuwais, Supervisor


Supplier Registration&Qualification Unit
Supplier Relationship Management Div

It is the responsibility of the supplier to update Saudi Aramco Supplier Registration Profile thorugh Ariba for
the following:
1. Change of Name / Commercial Registration Number / Address / Owner(s)
2. Any change of the supplier location
3. Discontinue supply of approved commodities (9COMs and 9CATS)

This is an electronically generated letter by Saudi Aramco. To verify Supplier approval status, please contact
Supplier Help Desk at supplierhelpdesk@aramco.com
3. Governmental
Certificates
A. Establishment
Registration Certificate
B. Chamber of Commerce
Membership
C. Industrial Investment
License - SAGIA
D. Zakat Certificate
E. VAT Registration
F. Social Insurance
Certificate - GOSI
G. Saudization Certificate
‫‪١٤٤٢/١٠/٠٦‬‬ ‫ﺍﻟﺘﺎﺭﻳﺦ‬
‫‪٢٠٢١/٠٥/١٨‬‬ ‫ﺍﻟﻤﻮﺍﻓﻖ‬
‫ﺭﻣﺰ ﺍﻟﺸﻬﺎﺩﺓ ‪٣٨٧١٢٩٣٨‬‬

‫ﺷﻬﺎﺩﺓ‬

‫ﺇﺳﻢ ﺍﻟﻤﻨﺸﺄﺓ ‪ :‬ﻣﺼﻨﻊ ﺭﺑﻴﻊ ﺍﻟﺘﻜﻴﻴﻒ‬


‫ﻓﻴﺼﻞ ﻋﻠﻲ ﻣﺤﻤﻮﺩ ﻣﺼﻄﻔﻰ‬ ‫ﺇﺳﻢ ﺻﺎﺣﺐ ﺍﻟﻌﻤﻞ ‪:‬‬
‫ﺹ‪.‬ﺏ ‪ ٣٩٠٩٨٢ :‬ﺍﻟﺮﻳﺎﺽ ‪١١٣٦٥‬‬
‫ﺍﻟﺴﻌﻮﺩﻳﺔ‬
‫‪٥٠١٠٧٨٠٥٠‬‬ ‫ﺭﻗﻢ ﺍﻹﺷﺘﺮﺍﻙ ‪:‬‬
‫ﻣﺼﺪﺭﻩ ‪ :‬ﺍﻟﺮﻳﺎﺽ‬ ‫ﺭﻗﻢ ﺍﻟﺴﺠﻞ ﺍﻟﺘﺠﺎﺭﻱ‪١٠١٠٢١١٧٢٦ :‬‬

‫ﻛﺘﺎﺑﺔ‬ ‫ﺭﻗﻤﺎ‬
‫ﺳﺒﻌﺔ ﻭ ﺍﺭﺑﻌﻮﻥ ﻣﺸﺘﺮﻛﺎ‬ ‫‪٤٧‬‬ ‫ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ‬
‫ﻣـﺎﺋﺔ ﻭ ﺳﺒﻌﺔ ﻭ ﺛﻼﺛﻮﻥ ﻣﺸﺘﺮﻛﺎ‬ ‫‪١٣٧‬‬ ‫ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﻏﻴﺮ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ‬
‫ﻣـﺎﺋﺔ ﻭ ﺃﺭﺑﻌﻪ ﻭ ﺛﻤﺎﻧﻮﻥ ﻣﺸﺘﺮﻛﺎ‬ ‫‪١٨٤‬‬ ‫ﺍﻟﻤﺠﻤﻮﻉ‬

‫ﺗﺸﻬﺪ ﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﺑﺄﻥ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﻤﺬﻛﻮﺭﺓ ﺃﻋﻼﻩ ﻗﺪ ﺃﻭﻓﺖ ﺑﺈﻟﺘﺰﺍﻣﺎﺗﻬﺎ ﺗﺠﺎﻩ ﺍﻟﻤﺆﺳﺴﺔ‬
‫ﻭﻓﻖ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻤﻘﺪﻣﺔ ﻣﻨﻬﺎ ﺣﺘﻰ ﺗﺎﺭﻳﺦ ﺇﺻﺪﺍﺭ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ‪ ،‬ﻭﺍﻟﺘﻲ ﺗﻢ ﻣﻨﺤﻬﺎ ﻟﺘﻘﺪﻳﻤﻬﺎ ﻷﻳﺔ ﺟﻬﺔ ﺗﻄﻠﺒﻬﺎ ‪ ،‬ﻭﻫﻲ‬
‫ﺻﺎﻟﺤﺔ ﻟﺠﻤﻴﻊ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ ﻧﺺ ﻋﻠﻴﻬﺎ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﻓﻲ ﺍﻟﻤﺎﺩﺓ )‪ (٦/١٩‬ﻣﻨﻪ‪.‬‬
‫ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﺳﺎﺭﻳﺔ ﺍﻟﻤﻔﻌﻮﻝ ﺣﺘﻰ ‪ ١٤٤٢/١١/٠٦‬ﻫـ‪.‬‬
‫ﻋﻦ ﻃﺮﻳﻖ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫ﺃﻭ‬ ‫ﻳﻠﺰﻡ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺻﺤﺔ ﻭﺻﻼﺣﻴﺔ ﺍﻟﺸﻬﺎﺩﺓ ﻋﺒﺮ ﺯﻳﺎﺭﺓ ﺍﻟﺮﺍﺑﻂ‬
‫ﺍﻟﺮﻣﺰ ﺍﻟﻤﻌﺮﻑ ﺍﻟﺘﺎﻟﻲ ‪:‬‬ ‫ﺃﺩﻧﺎﻩ ﻓﻲ ﺍﻟﻤﻮﻗﻊ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ ﻟﻠﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ‬

‫‪www.gosi.gov.sa/vc‬‬

‫) ﺍﻟﺸﻬﺎﺩﺓ ﻣﻌﺘﻤﺪﺓ ﻣﻦ ﺻﺎﺣﺐ ﺍﻟﺼﻼﺣﻴﺔ ﻭﻻ ﺗﺤﺘﺎﺝ ﺇﻟﻰ ﺗﻮﻗﻴﻊ ﺃﻭ ﺧﺘﻢ (‬

‫ﺗﻌﺪ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﻣﻦ ﺍﻟﻮﺛﺎﺋﻖ ﺍﻻﻟﻜﺘﺮﻭﻧﻴﺔ ﺍﻟﺤﻜﻮﻣﻴﺔ ﺍﻟﺮﺳﻤﻴﺔ ‪ ،‬ﻭﻳﺤﻈﺮ ﻗﻄﻌﻴﺎ ﺗﻘﻠﻴﺪﻫﺎ ﺃﻭ ﺇﺩﺧﺎﻝ ﺃﻱ ﺗﻌﺪﻳﻼﺕ ﻋﻠﻴﻬﺎ ﺳﻮﺍﺀ ﺑﺎﻹﺿﺎﻓﺔ ﺃﻭ ﺍﻟﺤﺬﻑ‬
‫ﺃﻭ ﺍﻟﺘﻐﻴﻴﺮ ﻓﻲ ﺑﻴﺎﻧﺎﺗﻬﺎ ﺃﻭ ﻏﻴﺮ ﺫﻟﻚ ﻣﻦ ﺍﻧﻮﺍﻉ ﺍﻟﺘﻌﺪﻳﻞ ‪ ،‬ﻭﺗﻌﺪ ﺍﻟﺸﻬﺎﺩﺓ ﻻﻏﻴﺔ ﺇﺫﺍ ﺷﺎﺑﻬﺎ ﺷﻲﺀ ﻣﻦ ﺫﻟﻚ ‪ ،‬ﻛﻤﺎ ﺗﻌﺮﺽ ﺻﺎﺣﺒﻬﺎ ﻟﻠﻤﻼﺣﻘﺔ ﺍﻟﻨﻈﺎﻣﻴﺔ‬
‫ﺃﻣﺎﻡ ﺍﻟﺠﻬﺎﺕ ﺍﻟﻤﺨﺘﺼﺔ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻣﺎﻳﻔﺮﺿﻪ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻣﻦ ﻋﻘﻮﺑﺎﺕ ‪ ،‬ﻭﻻﻳﺠﻮﺯ ﺗﺪﺍﻭﻝ ﺍﻟﺸﻬﺎﺩﺓ ﺇﻻ ﻓﻲ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ‬
‫ﺃﺻﺪﺭﺕ ﻷﺟﻠﻬﺎ ﻭﻓﻘﺎ ﻷﺣﻜﺎﻡ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ‪ ،‬ﻭﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻏﻴﺮ ﻣﺴﺆﻭﻟﻪ ﻋﻦ ﺃﻱ ﺁﺛﺎﺭ ﺃﺧﺮﻯ ﻣﺘﺮﺗﺒﺔ‬
‫ﻗﺒﻞ ﺍﻟﻐﻴﺮ ﻋﻦ ﺍﻟﺸﻬﺎﺩﺓ ﻭﻏﻴﺮ ﻣﺴﺆﻭﻟﺔ ﻋﻦ ﺃﻱ ﻋﻤﻠﻴﺔ ﺗﺰﻭﻳﺮ ﺃﻭ ﺗﻌﺪﻳﻞ ﺗﺘﻢ ﻋﻠﻰ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻴﻬﺎ ‪.‬‬
‫ﺗﺎﺭﻳﺦ ﺍﻹﺻﺪﺍﺭ ‪١٤٤٢/١٠/٠٦ :‬‬

‫ﺗﺎﺭﻳﺦ ﺻﻼﺣﻴﺔ ﺍﻟﺸﻬﺎﺩﺓ ‪١٤٤٣/٠١/١٠ :‬‬

‫ﺭﻗﻢ ﺍﻟﺸﻬﺎﺩﺓ ‪٢٠٠٠٢١٠٥٠٠١٧٣١ :‬‬

‫ﺍﺳﻢ ﺍﻟﻤﻨﺸﺄﺓ‪ :‬ﻣﺼﻨﻊ ﺭﺑﻴﻊ ﺍﻟﺘﻜﻴﻴﻒ‬

‫ﺭﻗﻢ ﺍﻟﻤﻠﻒ‪١٦٢٢٣٣-١ :‬‬

‫ﺳﺠﻞ ﺗﺠﺎﺭﻱ‪١٠١٠٢١١٧٢٦ :‬‬

‫ﺍﻟﺼﺎﺩﺭ ﻣﻦ‪ :‬ﺍﻟﺮﻳﺎﺽ‬

‫ﺗﺸﻬﺪ ﻭﺯﺍﺭﺓ ﺍﻟﻌﻤﻞ ﻭﺍﻟﺘﻨﻤﯿﺔ ﺍﻻﺟﺘﻤﺎﻋﯿﺔ ﺑﺄﻥ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﻤﺬﮐﻮﺭﺓ ﺃﻋﻼﻩ ﺣﻘﻘﺖ ﻧﺴﺐ ﺍﻟﺘﻮﻃﯿﻦ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻣﻨﻬﺎ‪..‬‬
‫ﻭﺗﻢ ﻣﻨﺤﻬﺎ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﺣﺴﺐ ﻃﻠﺒﻬﺎ‬

‫)ﺍﻟﺸﻬﺎﺩﺓ ﻣﻌﺘﻤﺪﺓ ﻣﻦ ﺻﺎﺣﺐ ﺍﻟﺼﻼﺣﻴﺔ ﻭﻻ ﺗﺤﺘﺎﺝ ﺇﻟﻰ ﺗﻮﻗﻴﻊ ﺃﻭ ﺧﺘﻢ(‬

‫ﺗﻨﺒﻴﻬﺎﺕ‪:‬‬

‫‪ - ١‬ﻳﻤﻜﻦ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺻﺤﺔ ﻭﺻﻼﺣﻴﺔ ﺍﻟﺸﻬﺎﺩﺓ ﻋﺒﺮ ﺯﻳﺎﺭﺓ ﺍﻟﺮﺍﺑﻂ‪:‬‬

‫‪ - ٢‬ﻓﻲ ﺣﺎﻝ ﺍﻛﺘﺸﺎﻑ ﺃﻱ ﻋﻤﻠﻴﺔ ﺗﺰﻭﻳﺮ ﻓﻲ ﺍﻟﺸﻬﺎﺩﺓ ﺍﻟﻤﻘﺪﻣﺔ ﻧﺮﺟﻮ ﺍﻟﺘﺒﻠﻴﻎ ﻋﻦ ﺫﻟﻚ ﺑﺨﻄﺎﺏ ﺭﺳﻤﻲ ﻷﻗﺮﺏ ﻣﻜﺘﺐ ﻋﻤﻞ‪.‬‬
4. Quality Certificates
A. ISO 9001
B. UL Certificate - Fire
Damper
C. UL Certificate - Fusible
Link
D. Henkel - Certificate of
Approval
E. Intertek - Test reports -
Air Outlets
CERTIFICATE
OF REGISTRATION

This is to certify that the management system of: Certificate Number:

Rabie Al-Takyeef Factory


QMS 21110908004 -06
Initial Certification Date:
13 November 2012
Date of Certification Decision:
Main Site: 4114, 75 Street, Second Industrial Area, Riyadh 14332-6676,
09 August 2018
Kingdom of Saudi Arabia
Issuing Date:

ISO 9001:2015
has been registered by Intertek as conforming to the requirements of:
09 August 2018
Valid Until:
22 September 2021

The management system is applicable to:


Manufacture of HVAC Outlets and Ducting

Calin Moldovean
President, Business Assurance
Intertek Certification Limited, 10A Victory
Park, Victory Road, Derby DE24 8ZF, United
Kingdom

Intertek Certification Limited is a


UKAS accredited body under
schedule of accreditation no. 014.

In the issuance of this certificate, Intertek assumes no liability to any party other than to the Client, and then only in accordance with the agreed upon Certification
Agreement. This certificate s validity is subject to the organization maintaining their system in accordance with Interteks requirements for systems certification. Validity may
be confirmed via email at certificate.validation@intertek.com or by scanning the code to the right with a smartphone. The certificate remains the property of Intertek, to
whom it must be returned upon request.
Performance Test Certificate
Issued To

RABIE AL-TAKYEEF FACTORY


KINGDOM OF SAUDI ARABIA

Intertek has tested a representative sample of


Rabie Al-Takyeef Factory Diffuser

A Three Slot Linear Slot Diffuser


was tested in accordance with the standards listed below and was found
to perform in a manner appropriate to the dictates of the standards.

STANDARDS

ASHRAE 70-1991 “Method of Testing for Rating


the Performance of Air Outlets and Inlets”

ADC 1062: GRD-84 “Test Code for Grilles, Registers and Diffusers”

SCOPE OF TESTING

The diffuser was tested for the following performance characteristics:


"Reference Intertek Report Number 3135170CRT-002 dated October 17, 2007”

A) Sound Power Level ((NC)


B) Air Velocity versus Static Pressure
C) Area Factor
D) Throw Pattern

Date: January 2, 2018

James R. Kline
Intertek
Engineer / Quality Supervisor

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or
distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested.
This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Performance Test Certificate
Issued To

RABIE AL-TAKYEEF FACTORY


KINGDOM OF SAUDI ARABIA

Intertek has tested representative samples of


Rabie Al-Takyeef Factory Air Grilles

1 meter by 2”, 1 meter by 5” and 1 meter by 10” Linear Bar Grilles


were tested in accordance with the standards listed below and were found
to perform in a manner appropriate to the dictates of the standards.

STANDARDS

ASHRAE 70-2006 “Method of Testing for Rating


the Performance of Air Outlets and Inlets”

ADC 1062: GRD-84 “Test Code for Grilles, Registers and Diffusers”

SCOPE OF TESTING

The grilles were tested for the following performance characteristics:


"Reference Intertek Report Numbers 103547626CRT-003a, 003b and 003c dated July 27, 2018”

A) Sound Power Level ((NC)


B) Air Velocity versus Static Pressure
C) Area Factor
D) Throw Pattern

Date: July 30, 2018

James R. Kline
Intertek
Engineer / Quality Supervisor

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or
distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested.
This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Performance Test Certificate
Issued To

RABIE AL-TAKYEEF FACTORY


KINGDOM OF SAUDI ARABIA

Intertek has tested representative samples of


Rabie Al-Takyeef Factory Air Grilles

10” by 6”, 16” by 10” and 30” by 12” Inlet Double Deflection Air Grilles
were tested in accordance with the standards listed below and were found
to perform in a manner appropriate to the dictates of the standards.

STANDARDS

ASHRAE 70-2006 “Method of Testing for Rating


the Performance of Air Outlets and Inlets”

ADC 1062: GRD-84 “Test Code for Grilles, Registers and Diffusers”

SCOPE OF TESTING

The grilles were tested for the following performance characteristics:


"Reference Intertek Report Numbers 103547626CRT-002a, 002b and 002c dated July 27, 2018”

A) Sound Power Level ((NC)


B) Air Velocity versus Static Pressure
C) Area Factor
D) Throw Pattern

Date: July 30, 2018

James R. Kline
Intertek
Engineer / Quality Supervisor

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or
distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested.
This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Performance Test Certificate
Issued To

RABIE AL-TAKYEEF FACTORY


KINGDOM OF SAUDI ARABIA

Intertek has tested a representative sample of


Rabie Al-Takyeef Factory Diffuser

A Square Four Way Ceiling Diffuser


was tested in accordance with the standards listed below and was found
to perform in a manner appropriate to the dictates of the standards.

STANDARDS

ASHRAE 70-1991 “Method of Testing for Rating


the Performance of Air Outlets and Inlets”

ADC 1062: GRD-84 “Test Code for Grilles, Registers and Diffusers”

SCOPE OF TESTING

The diffuser was tested for the following performance characteristics:


"Reference Intertek Report Number 3135170CRT-001 dated October 17, 2007”

A) Sound Power Level ((NC)


B) Air Velocity versus Static Pressure
C) Area Factor
D) Throw Pattern

Date: January 2, 2018

James R. Kline
Intertek
Engineer / Quality Supervisor

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or
distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested.
This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Performance Test Certificate
Issued To

RABIE AL-TAKYEEF FACTORY


KINGDOM OF SAUDI ARABIA

Intertek has tested representative samples of


Rabie Al-Takyeef Factory Diffusers

6”, 10” and 16” Diameter Inlet Round Ceiling Diffusers


were tested in accordance with the standards listed below and were found
to perform in a manner appropriate to the dictates of the standards.

STANDARDS

ASHRAE 70-2006 “Method of Testing for Rating


the Performance of Air Outlets and Inlets”

ADC 1062: GRD-84 “Test Code for Grilles, Registers and Diffusers”

SCOPE OF TESTING

The diffusers were tested for the following performance characteristics:


"Reference Intertek Report Numbers 103547626CRT-001a, 001b and 001c dated July 26, 2018”

A) Sound Power Level ((NC)


B) Air Velocity versus Static Pressure
C) Area Factor
D) Throw Pattern

Date: July 30, 2018

James R. Kline
Intertek
Engineer / Quality Supervisor

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or
distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested.
This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Performance Test Certificate
Issued To

RABIE AL-TAKYEEF FACTORY


KINGDOM OF SAUDI ARABIA

Intertek has tested representative samples of


Rabie Al-Takyeef Factory Duct Silencers

Three units (Models RSAR20-100 600Wx600Hx1000L, RSAR15-150 600Wx600Hx1000L


and RSAR15-150 600Wx600Hx2000L) were tested
in accordance with the standard listed below and were found
to perform in a manner appropriate to the dictates of the standard.

STANDARD

ASTM Standard E477-13, entitled “Standard Test Method for


Laboratory Measurements of Acoustical and Airflow Performance of
Duct Liner Materials and Prefabricated Silencers”.

SCOPE OF TESTING

The silencers were tested for the following performance characteristics:


"Reference Intertek Reports Number 102203005CRT-001a, 001b & 001c dated February 9, 2016”

A) Generated Sound Power Levels


B) Air Velocity versus Static Pressure
C) Insertion Loss in dB

Date: December 13, 2017

James R. Kline
Intertek
Engineer / Quality Supervisor

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or
distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested.
This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Performance Test Certificate
Issued To

RABIE AL-TAKYEEF FACTORY


KINGDOM OF SAUDI ARABIA

Intertek has tested representative samples of


Rabie Al-Takyeef Factory Single Duct Shut-Off VAV Samples.

VAV Models RAV-BS-200 and RAV-BS-250


were tested in accordance with the standards listed below and wee found
to perform in a manner appropriate to the dictates of the standards.

STANDARDS

AHRI 880-2011, “Performance Rating of Air Terminals” and


ASHRAE 130-2008, “Methods of Testing Air Terminal Units”.

SCOPE OF TESTING

The air terminals were tested for the following performance characteristics:
"Reference Intertek Report Numbers 102203005CRT-002a and 002b dated February 10, 2016”

A) Primary Airflow Rate, cfm


B) Radiated Sound Power Level, dB
C) Discharge Sound Power Level, dB

Date: December 13, 2017

James R. Kline
Intertek
Engineer / Quality Supervisor

This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in
accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or
distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested.
This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
EMME.R27026
Dampers for Fire Barrier and Smoke Applications

Page Bottom

Dampers for Fire Barrier and Smoke Applications

See General Information for Dampers for Fire Barrier and Smoke Applications

RABIE AL TAKYEEF FACTORY R27026


AL-MISHAL DISTRICT
PO BOX 390982
RIYADH, 11365 SAUDI ARABIA

Fire Dampers for Use in Static Systems

Damper
Hr Mounting Single Section Multiple Section
Model Class Position Damper Size, in. Damper Size, in.

W H W H

FDI 3 V 36 36 — —

FDI 3 H (Blade ramp attached 36 36 — —


at top and lead blade
pointing downwards)

Fire Dampers for Use in Dynamic Systems

Damper
Hr Mounting Single Section Multiple Section
Model Class Position Damper Size, in. Damper Size, in.

W H W H

FDI 3 V 36 36 — —

Last Updated on 2013-12-12

Questions? Print this page Terms of Use Page Top

© 2018 UL LLC

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory
with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in
the following format: "© 2018 UL LLC".
JGIX.R4059
Fusible Links

Page Bottom

Fusible Links

Se e Ge ne ral Inform ation for Fusible Link s

ELSIE MFG CO INC R 4059


600 W MAPLE ST
PO BO X 97
W ATER LO O , IN 46793 USA

Issue A, in the 135, 165, 212, 225, 350, 360, 370, 386°F te m pe rature ratings. For loads from 1 to 30 lbs incl. Be aring le ngth 2 in.

Issue AM, in the 165°F te m pe rature rating. For loads from 1 to 30 lbs. incl. Be aring le ngth 2 in.

Issue B, in the 135, 165, 212, 286, 350, 375°F te m pe rature ratings. For loads from 1 to 10 lbs incl. Be aring le ngth 1-3/16 in.

Issue C , in the 165, 212, 370°F te m pe rature ratings. For loads from 2 to 50 lbs incl. Be aring le ngth 3-3/8 in.

Issue D, in the 165, 212, 285, 286°F te m pe rature ratings. For loads from 1 to 40 lbs incl. Be aring le ngth 2 in.

Issue E, in the 165, 212, 286, 350, 360°F te m pe rature ratings. For loads from 2 to 50 lbs incl. Be aring le ngth 1-1/4 in.

Issue GFC housing fram e , in the 165, 212°F te m pe rature ratings. For loads from 4 to 40 lbs incl.

Issue Y, in the 165, 212°F te m pe rature ratings. For loads from 1.25 to 40 lbs incl.

Last Update d on 2008-11-20

Q ue stions? Print this page Notice of Disclaim e r Page Top

C opyright © 2011 Unde rwrite rs Laboratorie s Inc.®

The appe arance of a com pany's nam e or product in this database doe s not in itse lf assure that products so ide ntifie d have be e n
m anufacture d unde r UL's Follow-Up Se rvice . O nly those products be aring the UL Mark should be conside re d to be Liste d and
cove re d unde r UL's Follow-Up Se rvice . Always look for the Mark on the product.

UL pe rm its the re production of the m ate rial containe d in the O nline C e rtification Dire ctory subje ct to the following conditions: 1.
The Guide Inform ation, De signs and/or Listings (file s) m ust be pre se nte d in the ir e ntire ty and in a non-m isle ading m anne r,
without any m anipulation of the data (or drawings). 2. The state m e nt "R e printe d from the O nline C e rtifications Dire ctory with
pe rm ission from Unde rwrite rs Laboratorie s Inc." m ust appe ar adjace nt to the e x tracte d m ate rial. In addition, the re printe d
m ate rial m ust include a copyright notice in the following form at: "C opyright © 2011 Unde rwrite rs Laboratorie s Inc.®"
CERTIFICATE OF COMPLIANCE
Certificate Number R27026
Report Reference R27026-20120628
Date 2021-March-17

Issued to: RABIE AL TAKYEEF FACTORY


4114, 75 St
Second Industrial Area
Riyadh11365 SA

This is to certify that DAMPERS FOR FIRE BARRIER AND SMOKE


representative samples of APPLICATIONS
See Addendum Page for Product Designation(s).

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 555-UL Standard for Safety for Fire Dampers

Additional Information: See the UL Online Certifications Directory at


https://iq.ulprospector.com for additional information

This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.

Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
CERTIFICATE OF COMPLIANCE
Certificate Number R27026
Report Reference R27026-20120628
Date 2021-March-17

This is to certify that representative samples of the product as specified on this certificate were tested according
to the current UL requirements

Models

USC- Fire Damper for Use in Static and Dynamic Systems, per the following nomenclature

Models FDI, FDO, FDR, FDSR and FDSO

Where,

FDI- Blades inside airstream

FDO- Blades outside airstream

FDR- Rectangular Connection

FDSR- Round Duct Connection

FDSO- Oval Duct Connection

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
5. Data Sheets

TO GET ONLINE DATASHEET PLEASE SCAN:

http://rabie-ac.com/Catalogues.html
LINEAR SLOT DIFFUSER (LSD)

RABIE extruded aluminum linear slot diffusers Model LSD are designed for use in
ceiling applications (wall application is also possible) to provide architectural
excellence and outstanding performance flexibility.
LSD comes in three models; supply (LSDS), return (LSDR) or dummy decorative diffuser
(LSDD). These diffusers are used in cooling, heating and other ventilation systems.
LSD is available in (1 to 8) slot configurations and in two slot opening widths (3/4” (20mm) and
1” (25mm)). Also LSD can be provided with unique curved design as required.
RABIE LSD has standard finish of high quality, hard baked electrostatic powder coating for
long life and easy cleaning. Standard color is white color RAL 9016, other colors are available
on request.

Linear Slot Diffuser Supply (LSDS)


LSDS is supplied with a pair of pattern deflectors in each slot to provide full flexibility in air
pattern adjustment. Also it is provided with two holed strips (hit and miss damper) of steel
(black color); one fixed and one movable to allow volume control dampening.
Linear Slot Diffuser Return (LSDR)
LSDR is supplied with one fixed holed strip of steel (black color).
Linear Slot Diffuser Dummy (LSDD)
LSDD is supplied with one fixed strip (no holes) of steel (black color).

RABIE Customer support department technicians are available to take actual measurements
at site upon request.

1
LINEAR SLOT DIFFUSER (LSD)

2
LINEAR SLOT DIFFUSER (LSD)

FLANGED END CAP (STANDARD) MITERED END CAP


Option F Option M

WITHOUT END CAP FLAT END CAP


Option W Option C

Overall Length = L Overall Length = L

3
LINEAR SLOT DIFFUSER (LSD)

LSDS LSDR

LSDD

S = 3/4" or 20 mm S = 1" or 25 mm
NO. OF SLOTS N F N F
inches mm inches mm inches mm inches mm
1 1-13/16 46 3-1/8 79 2 50 3-1/4 83
2 3-1/4 83 4-5/8 117 3-9/16 91 4-15/16 125
3 4-3/4 120 6-1/16 154 5-3/16 132 6-9/16 166
4 6-1/4 158 7-1/2 191 6-7/8 174 8-1/8 207
5 7-11/16 195 9 228 8-7/16 215 9-3/4 248
6 9-1/8 232 10-7/16 265 10-1/16 256 11-3/8 289
7 10-9/16 269 11-7/8 302 11-11/16 297 13 330
8 12-1/16 306 13-3/8 339 13-5/16 338 14-5/8 371

4
LINEAR SLOT DIFFUSER (LSD)

DIFFUSER SEGMENTS

θ = Angle in degrees.
R = Radius.
H = Segment height.
= R × (1-COS(θ /2))
s Ls = Segment Length.
= 2 × R × (SIN (θ /2))
L = Arc length
= θ × (p / 180) × R

LSD-V
CURVED LINEAR SLOT DIFFUSER FOR CEILING

Radius up to diffuser inner neck

− Minimum radius for any curve or circle 1 meter. Otherwise, consult Rabie representative
− Curved slot diffuser is supplied with single holed strip and with no deflectors whether it is
supply or return.
− Minimum two dimensions are required for curves e.g. L & R. Otherwise, please bring
forma (a cut to actual carton)

5
LINEAR SLOT DIFFUSER (LSD)

CURVED LINEAR SLOT DIFFUSER FOR WALL

LSD-VI (INSIDE WALL)


NECK SIDE

FACE SIDE

LSD-VO (OUTSIDE WALL)

NECK SIDE

FACE SIDE

− Minimum radius for any curve or circle 1 meter. Otherwise, consult Rabie representative
− Curved slot diffuser is supplied with single holed strip and with no deflectors whether it is
supply or return.
− Minimum two dimensions are required for curves e.g. L & R. Otherwise, please bring
forma (a cut to actual carton)

6
LINEAR SLOT DIFFUSER (LSD)

LSD**-NI
SIDE WALL - INSIDE

LSD**-NO
SIDE WALL - OUTSIDE

X
X

Y
X1

Y
ANGLE
Y1

X1

Y1

LSD*-N
CEILING CORNER (FACE VIEW)

* S for supply and R for return

CORNER PIECES
- Minimum X1 or Y1 = 6”
- Available standard angles 90° and 135°.

7
LINEAR SLOT DIFFUSER (LSD)

NO. OF SLOTS CFM/FOOT


1 10 - 100
2 20 - 125
3 30 - 150
4 40 - 200
5 50 - 250
6 60 - 300
7 70 - 350
8 80 - 400

Area Factor
The following table shows the Area Factor (Ak) that represents horizontal throw (supply with
air deflected horizontally), vertical throw (supply with air deflected vertically) and for Return
(without deflectors).
Slot Number of
Horizontal Vertical Return
Width Slots
1 0.073 0.121 0.123
2 0.135 0.180 0.184
3 0.201 0.237 0.242
4 0.265 0.295 0.301
3/4"
5 0.330 0.355 0.362
6 0.395 0.413 0.421
7 0.455 0.470 0.479
8 0.520 0.530 0.539
1 0.088 0.184 0.188
2 0.162 0.274 0.281
3 0.241 0.360 0.367
4 0.318 0.448 0.457
1"
5 0.396 0.540 0.551
6 0.474 0.628 0.641
7 0.546 0.714 0.732
8 0.631 0.806 0.822

Knowing the volumetric flow rate required and active length of the diffuser (plenum box length
for example), you can then calculate the required flow / length.
At the table, you can pivot the required flow/length to the required throw, and then you can
find on the left the applicable slot width and number.
Example:
If total flow required into the room is 500CFM, and the effective diffuser length is 5 feet, then
the target flow/length is 100 CFM/Ft. If the required throw horizontally is 38 feet, then from
performance tables you can select 6 slot 3/4”. Then the resultant NC shall be less than 20.

8
LINEAR SLOT DIFFUSER (LSD)

No. of
CFM/FT. 10 20 30 40 50 60 70 80 90 100 125 150 200 250 300 350 400
Slots
HOR. SP .022 .089 .200 .356 .557 .802 1.092 1.426 1.804 2.228
THROW 7-10 13-15 15-19 18-21 20-24 22-26 23-28 25-30 27-32 28-33
NC <20 <20 30 39 41 47 >50 >50 >50 >50
1
VERT. SP .010 .039 .088 .157 .245 .353 .480 .627 .794 .980
THROW 2-5 9-15 16-23 22-27 25-30 27-32 29-35 31-37 33-39 35-42
NC <20 <20 <20 20 27 33 38 42 146 49
HOR. SP .022 .050 .089 .139 .200 .273 .356 .451 .557 .870
THROW 9-13 14-19 18-21 20-24 22-26 23-28 25-30 27-32 28-33 31-37
NC <20 <20 <20 28 33 38 42 46 >50 >50
2
VERT. SP .010 .022 .039 .061 .088 .120 .157 .199 .245 .383
THROW 3-6 7-13 12-21 19-26 23-31 27-35 30-37 33-39 35-42 39-46
NC <20 <20 <20 <20 <20 <20 23 27 30 37
HOR. SP .022 .040 .062 .089 .121 .158 .200 .248 .387 .557
THROW 11-16 15-21 19-24 23-26 23-28 25-30 27-32 28-33 31-37 34-41
NC <20 <20 <20 22 27 31 35 38 46 50
3
VERT. SP .010 .017 .027 .039 .053 .070 .088 .109 .170 .245
THROW 4-8 7-13 10-20 15-26 20-30 25-34 28-38 31-42 39-46 43-51
NC <20 <20 <20 <20 <20 <20 <20 <20 26 32
HOR. SP .022 .035 .050 .068 .089 .113 .139 .218 .313 .557
THROW 13-18 16-23 20-27 23-28 26-30 27-32 28-33 31-37 34-41 40-47
NC <20 <20 <20 <20 24 27 31 38 43 >50
4
VERT. SP .010 .015 .022 .030 .039 .050 .061 .096 .138 .245
THROW 4-9 7-13 10-18 13-25 17-30 22-33 27-36 34-46 40-51 50-58
NC <20 <20 <20 <20 <20 <20 <20 <20 24 33
HOR. SP .022 .032 .044 .057 .072 .089 .139 .200 .356 .557
THROW 15-20 18-24 20-28 23-30 26-32 29-33 31-37 34-41 40-46 44-52
NC <20 <20 <20 <20 21 24 32 37 46 >50
5
VERT. SP .010 .014 .019 .025 .032 .039 .061 .088 .157 .245
THROW 5-10 7-13 9-18 12-23 16-29 19-33 30-41 36-49 48-58 56-65
NC <20 <20 <20 <20 <20 <20 <20 <20 27 34
HOR. SP .022 .030 .040 .050 .062 .097 .139 .248 .387 .557
THROW 16-22 19-26 21-29 24-33 27-35 31-37 34-41 40-47 44-52 48-57
NC <20 <20 <20 <20 <20 27 32 41 49 >50
6
VERT. SP .010 .013 .017 .022 .027 .043 .061 .109 .170 .245
THROW 5-10 7-14 9-18 12-22 15-27 23-38 33-45 44-58 55-65 61-71
NC <20 <20 <20 <20 <20 <20 <20 22 29 35
HOR. SP .022 .029 .037 .045 .071 .102 .182 .284 .409 .557
THROW 17-24 20-27 22-31 35-34 31-37 34-41 40-47 44-52 48-56 52-61
NC <20 <20 <20 <20 22 28 37 44 50 >50
7
VERT. SP .010 .013 .016 .020 .031 .045 .080 .125 .180 .245
THROW 6-11 7-14 9-18 12-22 18-33 26-42 41-55 51-65 61-70 66-77
NC <20 <20 <20 <20 <20 <20 <20 25 31 37
HOR. SP .022 .028 .035 .054 .078 .139 .218 .313 .426 .557
THROW 18-26 21-29 23-32 29-37 35-41 40-47 44-52 48-56 52-61 56-66
NC <20 <20 <20 <20 24 34 41 46 50 >50
8
VERT. SP .010 .012 .015 .024 .034 .061 .096 .138 .188 .245
THROW 6-12 8-15 10-18 15-28 22-39 38-52 48-64 57-70 66-77 70-82
NC <20 <20 <20 <20 <20 <20 21 27 32 36

• NC Data based on 10dB room attenuation


• Throw (in feet) Data based on isothermal air at 100 and 50 fpm terminal velocity respectively.
• Horizontal Throw is 1 way pattern.
• Static Pressure (SP) in inches w.g.

9
LINEAR SLOT DIFFUSER (LSD)

No. of
CFM/FT. 10 20 30 40 50 60 70 80 90 100 125 150 200 250 300 350 400
Slots
HOR. SP .010 .040 .090 .160 .250 .360 .490 .640 .810 1.000
THROW 4-8 10-15 15-19 18-21 20-24 22-26 23-28 25-30 27-32 28-33
NC <20 <20 25 34 41 47 >50 >50 >50 >50
1
VERT. SP .007 .029 .066 .117 .183 .263 .358 .468 .592 .731
THROW 2-4 8-15 16-22 21-27 25-29 27-32 29-35 31-37 33-39 35-42
NC <20 <20 <20 <20 21 27 32 36 40 43
HOR. SP .010 .023 .040 .063 .090 .122 .160 .203 .250 .391
THROW 6-11 11-15 14-20 18-24 22-26 23-28 25-30 27-32 28-33 31-37
NC <20 <20 <20 22 28 33 37 41 44 50
2
VERT. SP .007 .016 .029 .046 .066 .089 .117 .148 .183 .285
THROW 3-6 6-12 11-21 17-25 22-30 26-35 29-37 33-39 35-42 39-46
NC <20 <20 <20 <20 <20 <20 <20 21 24 31
HOR. SP .010 .018 .028 .040 .054 .071 .090 .111 .174 .250
THROW 7-13 12-17 15-21 18-24 21-28 23-30 26-32 28-33 31-37 34-41
NC <20 <20 <20 <20 22 26 30 33 40 46
3
VERT. SP .007 .013 .020 .029 .040 .052 .066 .081 .127 .183
THROW 3-7 6-12 9-18 13-24 18-29 24-33 27-37 30-41 37-46 43-51
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 26
HOR. SP .010 .016 .023 .031 .040 .051 .063 .098 .141 .250
THROW 8-15 13-18 15-21 18-25 20-28 23-32 25-33 32-37 34-41 40-47
NC <20 <20 <20 <20 <20 22 25 32 38 47
4
VERT. SP .007 .011 .016 .022 .029 .037 .046 .071 .103 .183
THROW 4-8 6-12 9-17 12-22 16-29 20-32 24-36 32-44 39-51 50-58
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 27
HOR. SP .010 .014 .020 .026 .032 .040 .063 .090 .160 .250
THROW 9-16 13-19 16-22 18-25 20-28 23-31 28-37 34-41 40-47 44-51
NC <20 <20 <20 <20 <20 <20 26 32 41 48
5
VERT. SP .007 .011 .014 .019 .024 .029 .046 .066 .117 .183
THROW 4-9 6-12 9-16 11-21 14-26 17-32 27-40 35-47 46-58 56-65
NC <20 <20 <20 <20 <20 <20 <20 <20 21 28
HOR. SP .010 .014 .018 .023 .028 .043 .063 .111 .174 .250
THROW 10-18 14-20 17-23 19-26 21-29 29-36 31-41 40-47 44-52 48-57
NC <20 <20 <20 <20 <20 21 27 36 43 49
6
VERT. SP .007 .010 .013 .016 .020 .032 .046 .081 .127 .183
THROW 5-9 6-13 8-16 11-20 13-25 21-36 20-43 42-58 53-65 61-71
NC <20 <20 <20 <20 <20 <20 <20 <20 23 29
HOR. SP .010 .013 .017 .020 .032 .046 .082 .128 .184 .250
THROW 11-19 14-22 17-24 19-27 24-33 29-39 38-47 44-52 48-57 52-61
NC <20 <20 <20 <20 <20 23 32 39 45 50
7
VERT. SP .007 .010 .012 .015 .023 .034 .060 .093 .134 .183
THROW 5-10 7-13 9-16 11-20 16-30 24-40 39-53 49-65 59-71 66-77
NC <20 <20 <20 <20 <20 <20 <20 <20 25 30
HOR. SP .010 .013 .016 .024 .035 .063 .098 .141 .191 .250
THROW 12-20 15-23 18-25 22-31 27-37 36-47 45-52 48-57 52-61 56-66
NC <20 <20 <20 <20 <20 28 35 41 46 50
8
VERT. SP .007 .009 .011 .018 .026 .046 .071 .103 .140 .183
THROW 6-11 7-13 9-16 13-25 19-35 34-50 46-62 55-71 64-77 70-82
NC <20 <20 <20 <20 <20 <20 <20 21 26 30

• NC Data based on 10dB room attenuation


• Throw (in feet) Data based on isothermal air at 100 and 50 fpm terminal velocity respectively.
• Horizontal Throw is 1 way pattern.
• Static Pressure (SP) in inches w.g.

10
LINEAR SLOT DIFFUSER (LSD)

No. of
Negative SP .015 .062 .134 .241 .372 .549 .756 .991
Slots
CFM/Foot 10 20 30 40 50 60 70 80
1
NC <20 <20 <20 22 27 32 37 42
CFM/Foot 20 40 60 80 100 120 140 160
2
NC <20 <20 24 32 38 43 48 >50
CFM/Foot 30 60 90 120 150 180 210 240
3
NC <20 <20 30 38 42 49 >50 >50
CFM/Foot 40 80 120 160 200 240 280 320
4
NC <20 23 34 43 48 >50 >50 >50
CFM/Foot 50 100 150 200 250 300 350 400
5
NC <20 26 38 46 >50 >50 >50 >50
CFM/Foot 60 120 180 240 300 360 420 480
6
NC <20 29 40 48 >50 >50 >50 >50
CFM/Foot 70 140 210 280 350 420 490 560
7
NC <20 31 43 >50 >50 >50 >50 >50
CFM/Foot 80 160 240 320 400 480 560 640
8
NC <20 33 45 >50 >50 >50 >50 >50

No. of
Negative SP .026 .095 .154 .240 .344 .451 .574 .991
Slots
CFM/Foot 20 30 40 50 60 70 80 100
1
NC <20 <20 <20 21 26 30 32 38
CFM/Foot 40 60 80 100 120 140 160 200
2
NC <20 <20 23 29 31 37 41 44
CFM/Foot 60 90 120 150 180 210 240 300
3
NC <20 <20 25 32 36 40 45 50
CFM/Foot 80 120 160 200 240 280 320 400
4
NC <20 22 26 34 39 43 48 >50
CFM/Foot 100 150 200 250 300 350 400 500
5
NC <20 24 29 36 42 45 50 >50
CFM/Foot 120 180 240 300 360 420 480 600
6
NC <20 26 32 39 45 49 >50 >50
CFM/Foot 140 210 280 350 420 490 560 700
7
NC <20 29 36 43 48 >50 >50 >50
CFM/Foot 160 240 320 400 480 560 640 800
8
NC <20 31 40 46 >50 >50 >50 >50

• NC Data based on 10dB room attenuation


• Static Pressure (SP) in inches w.g.

11
LINEAR SLOT DIFFUSER (LSD)

D = N+10

Strap Plenum box Strap

Ceiling Ceiling

N N
F F

Ceiling

Screw

N
F Strip

12
LINEAR BAR GRILL (LBG)

RABIE extruded aluminum linear bar grille Model LBG is designed for use in wall, floor and
ceiling applications to provide architectural excellence and outstanding performance
flexibility.
LBG comes in many models; supply (LBGS), return (LBGR), bar and blade (LBGB), bar and
register (LBGG), core only (LBGC), frame without flange (LBGL) and floor grille (LBGF).
These bar grilles are used in cooling, heating and other ventilation systems.
LBG is available in different core construction. Also LBG can be provided with unique curved
designs as required.
RABIE LBG has standard finish of high quality, hard baked electrostatic powder coating for
long life and easy cleaning. Standard color is white color RAL 9016, other colors available on
request.

RABIE Customer support department technicians are available to take actual measurements
at site upon request.

1
LINEAR BAR GRILL (LBG)

Opposed Blade Damper

Lever Bush

Fixed Blade Pipe Frame

LINEAR BAR GRILLES RETURN LINEAR BAR GRILLES SUPPLY

LBGR LBGS

Is a linear bar grille composed of a set of fixed hori- Is a linear bar grille composed of a set of fixed hori-
zontal bars in the front face, used as a return grille. zontal bars in the front face, with opposed blade
damper (OBD) supplied to achieve air flow control,
lever operated through the face of the unit., used as
a supply grille.

Opposed
Blade Damper

Blade Blade
Bush
Bush

Frame
Fixed Blade Frame
Fixed Blade

LINEAR BAR & BLADE GRILLES LINEAR BAR & BLADE REGISTER

LBGB LBGG

Is a linear bar grille composed of a set of fixed hori- Is a linear bar grille composed of a set of fixed hori-
zontal bars in the front face and individually adjusta- zontal bars in the front face and individually adjusta-
ble vertical blades in the rear to control air flow pat- ble vertical blades in the rear to control air flow pat-
tern, used as a return grille. tern, used as a supply grille, opposed blade damper
(OBD) supplied to achieve air flow control, lever oper-
ated through the face of the unit.

2
LINEAR BAR GRILL (LBG)

Pipe

Blade

FRAMELESS BAR GRILLE FLANGELESS BAR GRILLE

LBGC LBGL

Is a linear bar grille core used as a supply or Is a linear bar grille with flangeless frame
return grille for recessed floor or ceiling air used as a supply or return grille for recessed
outlets. In recessed floor, it is not suitable for floor or ceiling air outlets. In recessed floor, it
walk paths. is not suitable for walk paths.

LINEAR FLOOR BAR GRILLE


LBGF
Is a linear bar grille used as a supply or return grille for re-
cessed floor air outlets. LBGF can stand up to 1000kg/m² load.

3
LINEAR BAR GRILL (LBG)

MITERED END CAP (STANDARD)


Option M
Overall Length = L+60

Overall Width
W+60
W

WITHOUT END CAP FLAT END CAP


Option W Option C

Overall Length = L Overall Length = L

4
LINEAR BAR GRILL (LBG)

W = Ceiling or wall opening (width)


W-7

2-7/16”
W - 10

(62)
63/64”
(25)
W - 18 1-5/16” W - 18 1-5/16”
(33) (33)
Linear Bar Grill Return Linear Bar Grill Supply
LBGR LBGS

W - 15

W - 10

3-2/8”
(82)
1-6/8”
(45)

W - 18 1-5/16” W - 18 1-5/16”
(33) (33)
Linear Bar & Blade Grille Linear Bar & Blade Register
LBGB LBGG

W - 10 Ceiling

W - 10
Ceiling

Flangeless Bar Grille Frameless Bar Grille


LBGL LBGC

Listed Widths W (inches)


2 2½ 3 3½ 4 5 6 8 10

5
LINEAR BAR GRILL (LBG)

Listed Length - 5 Listed Width - 5


1/2”
(13)

(19)
3/4”
(15)
5/8”
1/2’’
(13)

Floor Linear Bar Grille


LBGF

Blade Types

SPACING 1/2” (13mm) SPACING 1/2” (13mm)

ROUND PIPE ø8mm ROUND PIPE ø8mm

1/2” 1/8” 1/2” 7/32”


5/8”

5/8”
O° DEFLECTION FLAT O° DEFLECTION “T”

SPACING 1/2” (13mm) SPACING 1/2” (13mm)

ROUND PIPE ø8mm ROUND PIPE ø8mm

1/2” 7/32” 1/2” 7/32”


5/8”

5/8”

15° DEFLECTION 30° DEFLECTION

6
LINEAR BAR GRILL (LBG)

GRILL SEGMENTS

θ = Angle.
R = Radius.
H = Segment height.
s = R × (1-COS(θ /2))
Ls = Segment Length.
= 2 × R × (SIN (θ /2))
L = Arc length

= θ × (p / 180) × R

LBG-V
CURVED LINEAR BAR GRILL FOR CEILING

Radius up to grill inner neck

− Minimum radius for any curve or circular 1 meter. Otherwise, consult Rabie representative.
− Curved sections are supplied without OBD
− Minimum two dimensions are required for curves e.g. L & R. Otherwise, please bring a
forma (a cut to actual carton)

7
LINEAR BAR GRILL (LBG)

CURVED LINEAR BAR GRILL FOR WALL

LBG-VI
INSIDE WALL

NECK SIDE

FACE SIDE

LBG-VO
OUT SIDE WALL

NECK SIDE

FACE SIDE
− Minimum radius for any curve or circular 1 meter. Otherwise, consult Rabie representative.
− Curved sections are supplied without OBD
− Minimum two dimensions are required for curves e.g. L & R. Otherwise, please bring a
forma (a cut to actual carton)

8
LINEAR BAR GRILL (LBG)

LBG-NI
SIDE WALL - INSIDE CORNER

LBG-NO
SIDE WALL - OUTSIDE CORNER

X X
Y

X1 le
Y

Ang
X1
Y1

Y1

LBG-N
CEILING CORNERS (Face View)
CORNER PIECES
- Minimum X1 or Y1 = 6”
- Available standard angles 90° and 135°.

9
LINEAR BAR GRILL (LBG)

QUICK SELECTION TABLE

NOMINAL WIDTH CFM/FOOT


2” 00 - 20
3” 30 - 175
4” 50 - 225
5” 70 - 300
6” 90 - 350
8” 110 - 400
10” 130 - 450

Determine air volume flow rate per outlet.


Calculate flow rate per foot.
For supply air grille application, establish required throw.
Establish required maximum noise and pressure values.
From the following performance tables select the most suitable width that meets the
required throw (or more) at the calculated flow rate per foot, and meet required (or better)
NC, and pressure values.

Required:
Linear bar grille on side wall to throw 0.75m³/s into the room (0° deflection, “T” shape
blades). The opening length shall be 2 meters. The required throw shall be 4 meters and
NC shall not exceed 35. What shall be the width?
Solution:
First we should calculate the flow per foot:
0.75 m³/s = 1,589.2 CFM AND 2 m = 6.6 ft Then:
Flow per foot = 1,589.2/6.6 = 240.8 CFM/ft
Throw = 4m = 13.1 ft
Then from performance table on page 12 we can see that 5” wide LBG can be suitable
and will have noise rating of NC34 and throw much larger than required. Whereas 10”
wide LBG can be a better choice for more laminar flow as the throw shall be just slightly
bigger than required throw.
After consulting with the architect, you select any width between 5” and 10”.

10
LINEAR BAR GRILL (LBG)

1/2” 1/8”

5/8”
AREA
NOMINAL Sq. Ft. VELOCITY (FPM) 400 600 800 1000 1200 1400 1600 1800 2000
WIDTH (Effective
(Inches) free area/ TOTAL PRESSURE (in. W.G.) 0.009 0.020 0.036 0.057 0.080 0.109 0.143 0.182 0.225
Linear foot)
Flow, CFM / Foot 22 33 44 55 66 77 88 99 110
Throw, Feet Sill or floor 1-1 4-4 7-7 9-10 11-12 14-16 16-18 17-20 19-21
2 .055
Sidewall 5-7 8-12 11-16 14-20 17-23 19-26 21-28 23-30 25-33
NC <20 <20 <20 <20 23 27 31 34 37
Flow, CFM / Foot 30 44 59 74 89 104 118 133 148
Throw, Feet Sill or floor 1-1 5-5 9-9 11-12 14-15 16-17 19-20 21-23 24-25
2½ .074
Sidewall 6-8 9-13 13-17 16-21 18-24 21-28 24-31 27-35 31-39
NC <20 <20 <20 <20 22 26 30 33 36
Flow, CFM / Foot 38 58 77 96 115 134 154 173 192
Throw, Feet Sill or floor 2-2 7-7 10-11 13-14 16-17 19-20 21-23 24-25 25-26
3 .096
Sidewall 7-10 10-14 14-19 17-23 20-26 24-30 27-34 30-38 33-41
NC <20 <20 <20 <20 22 26 30 33 36
Flow, CFM / Foot 46 69 93 116 139 162 186 209 232
Throw, Feet Sill or floor 3-3 8-8 12-12 15-16 19-20 21-23 24-25 26-27 29-29
3½ .116
Sidewall 7-10 12-16 16-20 20-25 23-28 26-32 29-36 32-40 36-44
NC <20 <20 <20 <20 22 26 30 33 36
Flow, CFM / Foot 56 83 111 139 167 195 222 250 278
Throw, Feet Sill or floor 3-3 9-9 13-13 16-17 20-21 23-24 25-26 27-27 30-30
4 .139
Sidewall 8-11 13-17 17-21 20-25 25-30 28-34 30-37 35-42 38-45
NC <20 <20 <20 <20 23 27 31 34 37
Flow, CFM / Foot 72 107 143 179 215 250 286 322 358
Throw, Feet Sill or floor 4-4 10-10 14-14 18-18 22-23 24-24 27-28 30-31 32-32
5 .179
Sidewall 10-13 14-18 19-23 22-27 27-32 30-36 33-40 37-44 41-48
NC <20 <20 <20 <20 23 27 31 34 37
Flow, CFM / Foot 88 133 177 221 265 310 354 398 442
Throw, Feet Sill or floor 5-5 10-10 15-15 18-18 23-23 25-25 28-28 31-31 32-32
6 .221
Sidewall 12-15 16-20 20-24 24-29 29-34 33-39 35-41 40-46 44-50
NC <20 <20 <20 <20 24 28 32 35 38
Flow, CFM / Foot 109 163 218 272 326 381 435 490 544
Throw, Feet Sill or floor 6-6 11-11 16-16 19-19 24-24 26-26 29-29 32-32 33-33
8 .272
Sidewall 14-17 17-21 21-25 26-31 31-36 35-41 37-42 42-48 47-52
NC <20 <20 <20 20 25 29 33 36 39
Flow, CFM / Foot 134 202 268 336 403 470 536 605 672
Throw, Feet Sill or floor 7-7 11-11 17-17 19-19 25-25 27-27 30-31 33-33 34-34
10 .336
Sidewall 16-19 18-22 22-26 28-33 33-38 37-445 39-43 44-50 51-54
NC <20 <20 <20 20 26 30 34 37 40

11
LINEAR BAR GRILL (LBG)

1/2” 7/32”

5/8”
AREA
NOMINAL Sq. Ft. VELOCITY (FPM) 400 600 800 1000 1200 1400 1600 1800 2000
WIDTH (Effective
(Inches) free area/ TOTAL PRESSURE (in. W.G.) 0.010 0.022 0.040 0.063 0.089 0.121 0.159 0.202 0.250
Linear foot)
Flow, CFM / Foot 18 27 36 45 54 63 72 81 90
Throw, Feet Sill or floor 1-1 4-4 7-7 9-10 11-13 14-16 16-18 17-20 19-21
2 .045
Sidewall 5-7 9-12 11-16 14-20 16-23 19-26 21-28 22-30 25-33
NC <20 <20 <20 <20 23 28 32 35 38
Flow, CFM / Foot 26 40 53 66 79 92 106 119 132
Throw, Feet Sill or floor 2-2 6-6 8-9 12-13 14-16 17-19 20-22 22-23 23-24
2½ .066
Sidewall 6-9 9-12 12-17 16-22 19-25 21-28 25-32 28-36 30-39
NC <20 <20 <20 20 25 30 34 37 40
Flow, CFM / Foot 35 53 70 88 106 123 141 158 176
Throw, Feet Sill or floor 2-2 7-7 10-11 13-15 16-18 19-21 22-24 24-25 26-27
3 .088
Sidewall 7-10 11-15 14-19 17-23 21-27 24-31 27-34 31-39 34-42
NC <20 <20 <20 21 26 31 35 38 41
Flow, CFM / Foot 44 66 88 110 132 154 176 198 220
Throw, Feet Sill or floor 3-3 8-8 12-12 15-16 19-20 21-22 24-25 26-27 29-29
3½ .110
Sidewall 7-10 12-16 16-20 20-25 23-28 26-32 29-36 32-40 36-44
NC <20 <20 <20 22 27 32 36 39 42
Flow, CFM / Foot 53 80 106 133 160 186 213 239 266
Throw, Feet Sill or floor 3-3 9-9 13-13 16-17 20-21 23-24 25-26 28-28 31-31
4 .133
Sidewall 8-11 13-17 17-21 21-26 25-30 28-34 30-37 35-42 38-46
NC <20 <20 <20 23 28 33 37 40 43
Flow, CFM / Foot 71 106 142 177 212 248 283 318 354
Throw, Feet Sill or floor 4-4 10-10 15-15 18-18 22-23 25-25 27-28 30-30 34-34
5 .177
Sidewall 10-13 14-18 19-23 22-27 27-32 31-37 33-40 37-44 41-48
NC <20 <20 <20 24 29 34 38 41 44
Flow, CFM / Foot 89 133 178 222 266 310 355 440 444
Throw, Feet Sill or floor 5-5 10-10 15-15 19-19 23-23 25-25 29-29 31-31 36-36
6 .222
Sidewall 11-14 16-20 20-24 24-29 29-34 33-39 35-41 40-46 44-50
NC <20 <20 <20 25 30 35 39 42 45
Flow, CFM / Foot 110 164 219 274 329 384 438 493 548
Throw, Feet Sill or floor 6-6 11-11 16-16 20-20 24-24 26-26 30-30 32-32 37-37
8 .274
Sidewall 12-15 17-21 21-25 25-30 30-35 34-40 36-42 41-47 45-51
NC <20 <20 20 26 31 36 40 43 46
Flow, CFM / Foot 135 203 270 338 406 473 541 608 676
Throw, Feet Sill or floor 6-6 11-11 16-16 21-21 25-25 26-26 32-32 33-33 38-38
10 .338
Sidewall 13-16 19-23 22-26 27-32 32-37 36-42 38-43 43-49 48-53
NC <20 <20 21 27 32 37 41 44 47

12
LINEAR BAR GRILL (LBG)

1/2” 7/32”

5/8”
AREA
NOMINAL Sq. Ft. VELOCITY (FPM) 400 600 800 1000 1200 1400 1600 1800 2000
WIDTH (Effective
(Inches) free area/ TOTAL PRESSURE (in. W.G.) 0.009 0.020 0.036 0.057 0.080 0.109 0.143 0.182 0.225
Linear foot)
Flow, CFM / Foot 22 34 45 56 67 78 90 101 112
Throw, Feet Sill or floor 1-1 4-4 7-7 9-10 12-13 14-16 16-18 17-20 19-21
2 .056
Sidewall 5-7 8-12 11-16 14-20 17-23 18-25 20-27 22-30 26-34
NC <20 <20 <20 25 30 35 39 43 46
Flow, CFM / Foot 30 45 60 75 90 105 120 135 150
Throw, Feet Sill or floor 1-1 5-5 8-9 11-12 14-15 16-18 19-21 21-22 22-23
2½ .075
Sidewall 6-8 9-13 12-17 16-21 19-25 21-27 24-31 27-35 30-38
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 37 56 74 93 112 130 149 167 186
Throw, Feet Sill or floor 2-2 6-6 10-10 12-13 16-17 19-20 21-23 23-24 25-25
3 .093
Sidewall 6-9 10-14 13-18 17-22 20-26 24-30 26-33 30-37 32-40
NC <20 <20 <20 23 28 33 37 41 44
Flow, CFM / Foot 45 68 90 113 136 158 181 203 226
Throw, Feet Sill or floor 2-2 7-7 12-12 14-15 18-19 21-22 23-24 25-26 27-27
3½ .113
Sidewall 7-10 11-15 16-20 18-23 22-27 25-32 28-35 32-39 34-42
NC <20 <20 <20 23 28 33 37 41 44
Flow, CFM / Foot 53 80 106 133 160 186 212 239 266
Throw, Feet Sill or floor 3-3 8-9 13-13 15-16 19-20 22-23 24-25 26-27 30-30
4 .133
Sidewall 8-11 12-16 17-21 19-24 24-29 27-33 30-36 33-40 37-44
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 69 104 138 173 208 242 277 312 346
Throw, Feet Sill or floor 4-4 9-9 14-14 17-17 21-22 24-24 26-27 29-29 32-32
5 .173
Sidewall 10-13 14-18 19-23 21-26 25-31 29-35 33-38 35-42 39-46
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 85 127 170 212 254 296 339 382 424
Throw, Feet Sill or floor 5-5 10-10 15-15 18-18 23-23 25-25 28-28 30-30 34-34
6 .212
Sidewall 11-14 16-20 20-24 24-28 27-32 30-36 33-39 37-43 41-47
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 105 157 210 262 314 367 419 472 524
Throw, Feet Sill or floor 6-6 11-10 16-16 19-19 25-25 26-26 30-30 31-32 34-34
8 .262
Sidewall 12-15 18-22 21-25 27-30 29-33 31-37 34-40 39-44 44-48
NC <20 <20 <20 25 30 35 39 43 46
Flow, CFM / Foot 129 194 258 323 388 452 517 581 646
Throw, Feet Sill or floor 7-7 12-11 17-17 20-20 27-27 28-28 32-32 33-33 35-35
10 .323
Sidewall 13-15 20-24 21-25 30-32 31-34 32-38 34-40 40-45 45-50
NC <20 <20 20 26 30 36 40 44 47

13
LINEAR BAR GRILL (LBG)

1/2” 7/32”

5/8”
AREA
NOMINAL Sq. Ft. VELOCITY (FPM) 400 600 800 1000 1200 1400 1600 1800 2000
WIDTH (Effective
(Inches) free area/ TOTAL PRESSURE (in. W.G.) 0.009 0.020 0.036 0.057 0.080 0.109 0.143 0.182 0.225
Linear foot)
Flow, CFM / Foot 22 34 45 56 67 78 90 101 112
Throw, Feet Sill or floor 1-1 4-4 7-7 9-10 12-13 14-16 16-18 17-20 19-21
2 .056
Sidewall 5-7 8-12 11-16 14-20 17-23 18-25 20-27 22-30 26-34
NC <20 <20 <20 25 30 35 39 43 46
Flow, CFM / Foot 29 44 58 73 88 102 117 131 146
Throw, Feet Sill or floor 1-1 5-5 8-9 11-12 14-15 16-18 19-21 21-22 22-23
2½ .073
Sidewall 6-8 9-13 12-17 16-21 19-25 21-27 24-31 27-35 30-38
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 36 54 72 90 108 126 144 162 180
Throw, Feet Sill or floor 2-2 6-6 10-10 12-13 16-17 19-20 21-23 23-24 25-25
3 .090
Sidewall 6-9 10-14 13-18 17-22 20-26 24-30 26-33 30-37 32-40
NC <20 <20 <20 23 28 33 37 41 44
Flow, CFM / Foot 44 66 88 110 132 154 176 198 220
Throw, Feet Sill or floor 2-2 7-7 12-12 14-15 18-19 21-22 23-24 25-26 27-27
3½ .110
Sidewall 7-10 11-15 16-20 18-23 22-27 25-31 28-35 32-39 34-42
NC <20 <20 <20 23 28 33 37 41 444
Flow, CFM / Foot 51 77 102 128 154 179 205 230 256
Throw, Feet Sill or floor 3-3 8-9 13-13 15-16 19-20 22-23 24-25 26-27 30-30
4 .128
Sidewall 8-11 12-16 17-21 19-24 24-29 27-33 30-36 33-40 37-44
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 67 101 134 168 202 235 269 302 336
Throw, Feet Sill or floor 4-4 9-9 14-14 17-17 21-22 24-24 26-27 29-29 32-32
5 .168
Sidewall 10-13 14-18 19-23 21-26 25-31 29-35 33-38 35-42 39-46
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 79 118 158 197 236 276 315 355 394
Throw, Feet Sill or floor 5-5 10-10 15-15 18-18 23-23 25-25 28-28 30-30 34-34
6 .197
Sidewall 11-14 16-20 20-24 24-28 27-32 30-36 33-39 37-43 41-47
NC <20 <20 <20 24 29 34 38 42 45
Flow, CFM / Foot 96 144 192 240 288 336 384 432 480
Throw, Feet Sill or floor 6-6 11-10 16-16 19-19 25-25 26-26 30-30 31-32 34-34
8 .240
Sidewall 12-15 18-22 21-25 27-30 29-33 31-37 34-40 39-44 44-48
NC <20 <20 <20 25 30 35 39 43 46
Flow, CFM / Foot 118 178 237 296 355 414 474 533 592
Throw, Feet Sill or floor 7-7 12-11 17-17 20-20 27-27 28-28 32-32 33-33 35-35
10 .296
Sidewall 13-16 20-24 21-25 30-32 31-34 32-38 34-40 40-45 45-50
NC <20 <20 20 26 30 36 40 44 47

14
LINEAR BAR GRILL (LBG)

Option P: By Clamp and Strap (Plenum)

Option C: By Clamp and Strap (Ceiling)

Option R: By Spring Clip (Wall) Option S: By Screw (Wall or Ceiling)

Screw
Wall Wall or Ceiling

Spring Clip

Option X: On recessed ceiling or floor


(LBGC, LBGL or LBGF)
W - 18
W - 18

Ceiling

ALIGNMENT STRIPS

Strips

15
LINEAR BAR GRILL (LBG)

16
AIR GRILL AND REGISTER (AG)

SUPPLY AIR GRILL: A grill with two sets of adjustable blades, face blades can be requested
either horizontal or vertical shape , used as a side wall supply grill, individually adjustable blades
are spaced 3/4” on center, frame & blades are extruded aluminum alloy and polyester powder
coated.
SUPPLY AIR REGISTER: Is a supply air grill with opposed blade damper.
RETURN AIR GRILLE: A grill with a set of horizontal blades or vertical blades individually
adjustable blades and spaced 3/4” on center, used as a side wall return grille, frame & blades are
extruded aluminum alloy and polyester powder coated.
RETURN AIR REGISTER: Is a return air grill with opposed blade damper.

RABIE Customer support department technicians are available to take actual measurements
at site upon request.

1
AIR GRILL AND REGISTER (AG)

Opposed Blade Damper

Bush
Bush

Vertical Blade Vertical Blade

Horizontal Blade Frame Horizontal Blade Frame

Fig. A (AGDDH) Fig. B (AGDRH)


Opposed Blade Damper

Bush Bush

Horizontal Blade Horizontal Blade


Vertical Blade Frame Vertical Blade Frame

Fig. C (AGDDV) Fig. D (AGDRV)

Opposed Blade Damper

Bush

Horizontal Blade Frame Horizontal Blade Frame

Fig. E (AGSDH) Fig. F (AGSRH)


Opposed Blade Damper

Bush
Bush

Vertical Blade Frame Vertical Blade Frame

Fig. G (AGSDV) Fig. H (AGSRV)

2
AIR GRILL AND REGISTER (AG)

W - 15

W = Ceiling or wall opening (width)


W -10

3-2/8”
(82)
1-6/8”
3/4” (45) 3/4”
(20) W - 18 1-5/16” (20) W - 18 1-5/16”
(33) (33)
Fig. A (AGDDH) Fig. B (AGDRH)

W-7

W - 10

3-2/8”
(82)
1-6/8”
(45)

3/4” 3/4”
(20) W - 18 1-5/16” (20) W - 18 1-5/16”
(33) (33)
Fig. C (AGDDV) Fig. D (AGDRV)

Size (inches) CFM (range) Size (inches) CFM (range) Size (inches) CFM (range) Size (inches) CFM (range)
8x4 50-150 30 x 6 300-800 14 x 10 150-400 24 x 12 500-1000
10 x 4 50-200 32 x 6 300-800 16 x 10 200-500 28 x 12 500-1200
14 x 4 100-200 36 x 6 400-800 18 x 10 300-800 30 x 12 500-1300
18 X 4 100-250 10 x 8 100-250 20 x 10 300-800 32 x 12 500-1300
20 x 4 100-250 12 x 8 100-250 24 x 10 500-800 36 x 12 800-1400
24 x 4 100-250 16 x 8 150-300 28 x 10 500-1000 14 x 14 300-800
8x6 50-200 18 x 8 150-400 30 x 10 500-1000 16 x 14 400-800
10 x 6 100-200 20 x 8 200-500 32 x 10 500-1200 18 x 14 500-800
12 x 6 100-250 24 x 8 300-800 36 x 10 500-1300 24 x 14 500-1200
16 x 6 100-250 28 x 8 400-800 12 x 12 150-400 30 x 14 800-1400
18 x 6 100-250 30 x 8 500-800 14 x 12 200-500 16 x 16 500-800
20 x 6 100-300 32 x 8 500-800 16 x 12 300-800 20 x 16 500-1200
24 x 6 150-400 36 x 8 500-1000 18 x 12 400-800 24 x 16 500-1300
28 x 6 200-500 12 x 10 100-300 20 x 12 500-800 30 x 16 800-1400

- Maximum distance to make air grill as one section 50 cm for blade length.
- Other sizes are available upon request.

3
AIR GRILL AND REGISTER (AG)

W-7

W = Ceiling or wall opening (width)

W - 10

2-7/16”
(62)
63/64”
(25)
3/4” 3/4”
(20) W - 18 1-5/16” (20) W - 18 1-5/16”
(33) (33)
Fig. A (AGSDH) Fig. B (AGSRH)

W - 15

W - 10

2-7/16”
(62)
63/64”
(25)

W - 18 1-5/16” W - 18 1-5/16”
(33) (33)
Fig. C (AGSDV) Fig. D (AGSRV)

Size (inches) CFM (range) Size (inches) CFM (range) Size (inches) CFM (range) Size (inches) CFM (range)
8x4 50-150 30 x 6 300-800 14 x 10 150-400 24 x 12 500-1000
10 x 4 50-200 32 x 6 300-800 16 x 10 200-500 28 x 12 500-1200
14 x 4 100-200 36 x 6 400-800 18 x 10 300-800 30 x 12 500-1300
18 x 4 100-250 10 x 8 100-250 20 x 10 300-800 32 x 12 500-1300
20 x 4 100-250 12 x 8 100-250 24 x 10 500-800 36 x 12 800-1400
24 x 4 100-250 16 x 8 150-300 28 x 10 500-1000 14 x 14 300-800
8x6 50-200 18 x 8 150-400 30 x 10 500-1000 16 x 14 400-800
10 x 6 100-200 20 x 8 200-500 32 x 10 500-1200 18 x 14 500-800
12 x 6 100-250 24 x 8 300-800 36 x 10 500-1300 24 x 14 500-1200
16 x 6 100-250 28 x 8 400-800 12 x 12 150-400 30 x 14 800-1400
18 x 6 100-300 30 x 8 500-800 14 x 12 200-500 16 x 16 500-800
20 x 6 100-300 32 x 8 500-800 16 x 12 300-800 20 x 16 500-1200
24 x 6 150-400 36 x 8 500-1000 18 x 12 400-800 24 x 16 500-1300
28 x 6 200-500 12 x 10 100-300 20 x 12 500-800 30 x 16 800-1400

- Maximum distance to make air grill as one section 50 cm for blade length.
- Other sizes are available upon request.

4
AIR GRILL AND REGISTER (AG)

Overall Length = L+60

SIZES CFM
10" x 6" 100 - 200
12" x 6" 100 - 250
18" x 6" 100 - 250
20" x 6" 100 - 300
24" x 6" 150 - 400
12" x 8" 100 - 250
16" x 8" 150 - 300
20" x 8" 200 - 500
24" x 8" 300 - 800
30" x 8" 500 - 800
20" x 10" 300 - 800
24" x 10" 500 - 800
30" x 10" 500 - 1000
32" x 10" 500 - 1200
24" x 12" 500 - 1000
30" x 12" 500 - 1300
36" x 12" 800 - 1400

5
AIR GRILL AND REGISTER (AG)

Special Model to fit on round duct side opening

θ = Angle.
S
R = Duct Radius.
H = Segment height.
= R × (1-COS(θ /2))
Ls = Segment Length.
= 2 × R × (SIN (θ /2))
L = Arc length
= θ × (/ 180) × R

Radius up to inside
face of grill

Fig. A (AGSDH-VO)

6
AIR GRILL AND REGISTER (AG)

5x6 8x5 14 x 4 14 x 5 14 x 6 24 x 4
8x4 10 x 4 10 x 6 18 x 4 20 x 4 16 x 6
SIZES (in.)
CFM 6 x x6 8x6 12 x 5 12 x 6 16 x 5 12 x 8
(Width x Height) 12 x 4 16 x 4 10 x 8 20 x 5
10 x 5 10 x 10
Deflection 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45
Ak .16 .14 .13 .20 .18 .19 .27 .25 .23 .32 .30 .28 .36 .34 .31 .41 .40 .37
Velocity 315 355 385 250 280 295
Total Pressure .008 .012 .013 .005 .006 .007
50 Throw 7-10 4-6 3-6 7-10 3-6 3-5
NC <20 <20 <20 <20 <20 <20
Velocity 470 535 575 375 415 440
Total Pressure .018 .027 .029 .011 .014 .015
75 Throw 9-12 5-8 5-7 9-12 4-8 4-7
NC <20 <20 <20 <20 <20 <20
Velocity 625 715 770 500 555 590 370 400 435 315 330 355 280 295 325 245 250 270
Total Pressure .033 .048 .052 .020 .025 .027 .009 .013 .014 .006 .008 .008 .005 .006 .007 .004 .004 .004
100 Throw 10-14 6-9 6-8 10-14 6-9 6-8 10-14 5-9 5-8 10-14 5-9 4-8 10-14 5-9 4-8 9-15 5-8 4-7
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 780 892 625 625 695 735 463 500 545 390 415 445 345 370 405 305 315 340
Total Pressure .051 .075 .087 .031 .039 .042 .014 .020 .022 .009 .012 .013 .008 .009 .011 .006 .006 .006
125 Throw 11-16 7-11 7-9 11-16 7-10 7-9 11-16 6-9 6-8 11-16 6-9 5-8 11-16 6-9 5-8 11-16 6-10 5-8
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 940 1070 1155 750 835 882 555 600 650 480 500 535 415 440 485 365 375 405
Total Pressure .074 .109 .118 .045 .057 .061 .021 .028 .031 .014 .018 .019 .011 .013 .015 .008 .009 .010
150 Throw 12-17 8-11 7-10 12-17 8-11 7-10 12-17 8-11 7-10 12-18 7-11 7-10 12-18 7-11 7-10 12-17 6-11 6-10
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 875 972 1029 650 700 760 545 585 625 490 515 565 425 435 470
Total Pressure .066 .077 .083 .028 .038 .047 .020 .025 .026 .015 .018 .020 .011 .012 .014
175 Throw 13-18 9-12 8-11 13-18 9-12 8-11 13-19 8-12 8-11 13-19 8-12 8-12 13-19 7-12 7-11
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 1000 1100 1175 740 800 870 635 660 715 555 590 645 490 500 540
Total Pressure .081 .100 .109 .037 .052 .055 .025 .032 .034 .019 .023 .027 .014 .016 .017
200 Throw 14-20 9-13 8-11 14-20 9-13 8-11 14-20 9-12 8-11 14-20 9-12 8-12 14-20 8-12 7-12
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 705 750 805 625 660 725 550 565 610
Total Pressure .031 .041 .043 .024 .029 .034 .018 .020 .021
225 Throw 15-22 10-14 19-12 15-22 10-13 9-12 15-22 9-13 8-12
NC <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 780 835 895 695 735 805 615 625 675
Total Pressure .039 .050 .053 .030 .036 .042 .022 .025 .027
250 Throw 16-23 11-14 10-12 16-23 11-14 10-12 16-23 10-14 9-12
NC <20 <20 <20 <20 <20 <20 <20 <20 <20

CORE VELOCITY VELOCITY PRESSURE


(FPM) (inches w.g.)
250 0.004
300 0.006
350 0.008
400 0.010
450 0.013
500 0.016
550 0.019
600 0.022
650 0.026
700 0.031
750 0.035
800 0.040

Table 1 - Velocity Pressure


Conversion Chart

7
AIR GRILL AND REGISTER (AG)

18 x 6 20 x 6 16 x 8 24 x 6 36 x 4 20 x 8 22 x 8 24 x 8
26 x 4 12 x 10 18 x 8 30 x 5 16 x 10 36 x 5 16 x 12
SIZES (in.) 22 x 5 30 x 4 14 x 10 28 x 6 30 x 6
CFM 28 x 4 24 x 5 12 x 12 14 x 12 18 x 10
(Width x Height)
14 x 8 28 x 5 48 x 4
22 x 6 32 x 6
Deflection 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45
Ak .48 .44 .40 .52 .49 .44 .56 .52 .48 .66 .59 .52 .69 .65 .59 .85 .72 .63
Velocity 220 225 250 190 205 225
Total Pressure .002 .003 .004 .002 .002 .003
100 Throw 9-15 4-8 4-7 8-14 3-8 3-7
NC <20 <20 <20 <20 <20 <20
Velocity 260 265 315 240 255 285
Total Pressure .004 .005 .006 .003 .003 .005
125 Throw 11-16 5-10 6-9 10-16 4-9 4-9
NC <20 <20 <20 <20 <20 <20
Velocity 315 340 375 209 305 340 270 290 315 240 260 285
Total Pressure .005 .007 .008 .004 .006 .006 .004 .005 .005 .003 .004 .004
150 Throw 12-17 6-11 6-10 12-17 6-11 5-10 12-17 6-11 5-9 12-17 5-11 5-9
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 365 400 440 335 360 400 315 335 365 265 295 335
Total Pressure .007 .010 .011 .005 .008 .008 .005 .007 .007 .004 .006 .005
175 Throw 13-19 7-12 7-11 13-19 7-12 6-11 13-19 7-12 6-10 13-19 6-12 6-10
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 415 455 540 385 410 455 355 385 415 315 345 375 290 310 340
Total Pressure .010 .013 .014 .008 .010 .011 .007 .008 .009 .006 .006 .007 .004 .005 .006
200 Throw 14-20 8-12 7-11 14-20 8-13 7-11 14-20 8-12 7-11 4-20 7-12 6-11 13-20 7-13 6-11
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 470 510 560 432 460 510 400 430 470 340 380 430 325 345 380
Total Pressure .013 .016 .018 .010 .013 .014 .009 .010 .011 .007 .007 .009 .005 .006 .008
225 Throw 15-22 9-13 8-12 15-22 9-13 8-12 16-22 9-13 8-12 15-21 8-13 7-12 14-22 8-14 7-12
NC <20 <20 <20 <20 <20 <20 <20 <20 320 <20 <20 <20 <20 <20 <20
Velocity 520 570 625 480 550 570 445 480 520 395 430 470 360 385 430
Total Pressure .015 .020 .022 .012 .015 .018 .010 .013 .014 .009 .010 .012 .006 .007 .009
250 Throw 16-23 10-14 9-12 16-23 10-14 9-12 16-23 10-14 9-12 16-22 9-14 8-12 16-23 8-14 8-13
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 530 560 625 490 530 575 415 465 530 400 425 465
Total Pressure .017 .017 .022 .012 .015 .017 .010 .012 -016 .007 .008 .011
275 Throw 17-25 10-14 9-13 17-25 11-15 10-13 17-23 10-15 9-13 17-25 9-15 8-14
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 575 610 680 535 575 625 475 530 575 435 460 500 350 415 475
Total Pressure .017 .022 .025 .015 .019 .020 .012 .014 .017 .009 -011 .013 .007 .009 .010
300 Throw 17-25 11-15 10-13 17-25 11-15 10-13 17-25 11-16 10-14 17-26 10-15 9-14 17-24 9-16 9-14
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 -<20 <20 <20 <20 -<20 <20
Velocity 490 550 625 470 500 550 380 450 515
Total Pressure .013 .019 .020 .011 .013 .014 .008 .011 .012
325 Throw 18-26 11-17 10-15 18-27 11-16 10-14 18-26 10-17 10-15
NC <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 555 615 675 505 540 605 410 485 555
Total Pressure .017 .020 .023 .012 .015 .018 .010 .012 .013
350 Throw 19-27 12-17 10-15 19-27 11-17 10-15 19-27 11-17 10-15
NC <20 <20 <20 <20 <20 <20 <20 320 <20
Velocity 570 635 720 545 575 635 440 520 595
Total Pressure .019 .022 .026 .014 .017 .020 .011 .014 .015
375 Throw 19-28 12-17 11-16 20-29 12-18 10-16 20-29 12-18 11-16
NC <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 635 700 770 580 615 685 470 555 635
Total Pressure .022 .026 .030 .016 .019 .023 .013 .016 -019
400 Throw 20-29 13-18 11-16 20-29 13-18 11-16 20-29 13-18 11-16
NC <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 815 655 720 500 590 675
Total Pressure .018 .021 .026 .015 .018 .021
425 Throw 21-30 14-19 12-17 21-30 14-19 12-17
NC <20 <20 <20 <20 <20 <20
Velocity 650 690 770 530 625 715
Total Pressure .020 .025 .030 .016 .020 .023
450 Throw 21-31 15-20 12-18 21-30 14-19 12-17
NC <20 <20 <20 <20 <20 <20
Velocity 690 730 805 560 660 755
Total Pressure .022 .028 .033 .018 .022 .026
475 Throw 22-33 16-21 12-19 22-32 14-20 12-18
NC <20 <20 c20 <20 <20 <20
Velocity 725 770 845 590 695 795
Total Pressure .025 .030 .037 .020 .025 .027
500 Throw 22-23 16-21 13-19 23-32 14-20 12-18
NC <20 <20 320 <20 <20 <20
Velocity 650 765 875
Total Pressure .024 -030 .035
550 Throw 24-34 15-21 13-18
NC <20 <20 <20

8
AIR GRILL AND REGISTER (AG)

14 x 14 36 x 6 30 x 8 16x16 28 x 10 32 x 10 36 x 10
20 x 10 18 x 12 24 x 10 20 x 14 20 x 16 30 x 12
SIZES (in.) 34 x 6 22 x 10 18 x 14 48 x 6 40 x 8 20 x 18
CFM 28 x 8 48 x 5 36 x 8 18 x 18 48 x 8
(Width x Height)
16 x 14 20 x 12 24 x 12 28 x 12 32 x 12
32 x 8 24 x 14 24 x 14 32 x 16
Deflection 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45
Ak .82 .76 .69 .94 .88 .79 1.06 .98 .90 1.22 1.14 1.03 1.38 1.29 1.16 1.51 1.42 1.28
Velocity 365 395 435
Total Pressure .005 .007 .008
300 Throw 17-24 9-16 9-14
NC <20 <20 <20
Velocity 395 430 470
Total Pressure .006 .008 .009
325 Throw 18-26 10-17 10-15
NC <20 <20 <20
Velocity 425 460 505
Total Pressure .007 .010 012
350 Throw 19-27 11-17 10-15
NC <20 <20 <20
Velocity 455 495 540
Total Pressure .008 .011 .012
375 Throw 20-28 12-18 11-16
NC <20 <20 <20
Velocity 490 525 580 425 455 505
Total Pressure .009 .013 .015 .008 .009 .011
400 Throw 20-29 12-18 11-16 20-29 12-18 11-16
NC <20 <20 <20 <20 <20 <20
Velocity 520 560 615 452 485 540
Total Pressure .010 .015 .017 .009 010 012
425 Throw 21-30 13-19 12-16 21-30 13-19 12-17
NC <20 <20 <20 <20 <20 <20
Velocity 550 590 650 480 510 570
Total Pressure .011 .016 .019 .010 .012 .014
450 Throw 21-30 13-19 12-16 21-30 13-19 12-17
NC <20 <20 <20 <20 <20 <20
Velocity 580 625 688 505 540 600
Total Pressure .012 .018 .021 .011 .013 .016
475 Throw 22-31 14-20 12-17 22-31 14-20 12-17
NC <20 <20 <20 <20 <20 <20
Velocity 610 680 725 530 570 635 470 510 555 400 430 490 360 390 430 330 350 380
Total Pressure .013 .019 .023 .012 .014 .017 .010 .011 .014 .006 .007 .009 .005 .006 .007 .004 .005 .006
500 Throw 23-32 14-20 12-17 23-32 14-20 12-18 23-32 14-20 12-18 22-32 12-20 12-18 22-32 12-20 11-18 22-31 12-20 11-18
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 670 725 795 585 625 695 520 560 810 430 460 515 400 425 475 365 385 430
Total Pressure .016 .024 .029 .015 .017 .021 .012 .014 .017 .007 .008 .010 .006 .007 .008 .005 .006 .007
550 Throw 24-34 15-21 13-18 24-34 15-21 13-18 23-34 15-21 13-18 23-33 13-20 13-18 23-33 13-20 12-18 23-33 13-20 12-18
NC <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20 <20

9
AIR GRILL AND REGISTER (AG)

22 x 8 24 x 8 14 x 14 36 x 6 30 x 8 16 x 16 28 x 10 32 x 10
36 x 5 16 x 12 20 x 10 18 x 12 24 x 10 20 x 14 20 x 16
SIZES (in.) 30 x 6 34 x 6 22 x 10 18 x 14 48 x 6 40 x 8
CFM 18 x 10 28 x 8 48 x 5 36 x 8 18 x 18
(Width x Height)
48 x 4 16 x 14 20 x 12 24 x 12 28 x 12
32 x 6 32 x 8 30 x 10 24 x 14
Deflection 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45
Ak .83 .72 .63 .85 .76 .69 .94 .88 .79 1.06 .98 .90 1.22 1.14 1.03 1.38 1.29 1.16
Velocity 720 835 950 705 790 870 640 680 760 565 610 665 460 515 590 435 465 515
Total Pressure .028 .036 .042 .019 .028 .034 .018 .021 .025 .014 .016 .021 .009 .010 .012 .007 .008 .010
600 Throw 25-35 15-22 14-19 25-35 16-22 14-19 25-35 15-22 14-19 24-35 15-22 14-19 24-34 15-22 14-19 24.34 15-22 14-19
NC 22 23 23 21 22 22 20 20 20 <20 <20 <20 <20 <20 <20 <20 <20 <20
Velocity 785 900 1030 765 855 940 690 740 825 615 665 720 510 585 650 470 505 560
Total Pressure .031 .042 .051 .022 .033 .039 .021 .025 .029 .016 .019 .025 .010 .011 .015 .008 .009 .012
650 Throw 25-36 16-23 15-21 26-37 17-24 15-20 26-37 16-23 15-20 26-37 16-23 15-20 25-35 16-23 14-20 25-35 16-23 14-20
NC 24 26 27 24 25 25 23 23 23 22 23 23 <20 20 21 <20 <20 <20
Velocity 845 970 1110 825 920 1015 745 795 885 660 715 780 595 635 690 505 545 605
Total Pressure .039 .049 .53 .028 .037 .045 .024 .028 .034 .019 .021 .028 .012 .013 .017 .009 .011 .014
700 Throw 26-38 17-24 15-21 27-38 17-24 15-21 27-38 17-24 15-21 26-38 17-23 15-20 27-39 17-24 15-21 27-39 17-24 15-21
NC 26 27 29 26 27 27 25 25 26 24 24 24 23 23 23 20 20 20
Velocity 905 1040 1190 880 985 1090 800 855 950 710 765 830 615 660 730 545 580 645
Total Pressure .045 .060 .061 .029 .042 .052 .027 .032 .039 .022 .024 .032 .013 .014 .019 .010 .012 .016
750 Throw 28-40 18-25 16-22 28-40 18-26 16-22 28-40 18-26 16-22 28-40 18-24 16-21 28-40 18-25 16-22 29-40 18-25 16-22
NC 29 30 32 29 29 31 28 28 29 27 27 28 25 25 26 23 22 22
Velocity 965 1110 1230 940 1055 1160 850 910 1015 755 815 890 690 720 780 580 620 690
Total Pressure .051 .064 .069 .034 .048 .058 .032 .036 .044 .025 .028 .037 .016 .017 .022 .012 .014 .018
800 Throw 29-43 18-25 16-22 29-43 18-25 16-22 28-42 18-25 16-22 28-40 18-24 16-21 29-41 18-26 16-22 29-41 18-26 16-22
NC 31 32 33 31 31 32 29 30 30 28 28 28 27 27 27 24 25 25
Velocity 740 795 865 650 700 775
Total Pressure .020 .022 .028 .015 .017 .022
900 Throw 30-43 19-27 17-23 30-43 19-28 17-23
NC 30 30 30 26 29 29
Velocity 830 880 965 725 775 860
Total Pressure .025 .027 .034 .018 .021 .028
1000 Throw 32-46 20-28 17-25 32-47 21-30 18-25
NC 34 34 34 32 32 32
Velocity 795 855 950
Total Pressure .022 .026 .033
1100 Throw 33-47 21-30 18-26
NC 35 35 36
Velocity 870 930 1035
Total Pressure .026 .030 .040
1200 Throw 35-49 22-31 19-27
NC 38 38 38

10
AIR GRILL AND REGISTER (AG)

36 x 10 28 x 14 30 x 14 30 x 16 50 x 10 24 x 24
30 x 12 22 x 18 24 x 18 40 x 12 42 x 12 26 x 16
SIZES (in.) 20 x 18 20 x 20 36 x12 48 x 10 36 x 14 48 x 12
CFM 48 x 8 40 x 10 60 x 8 28 x 18 72 x 8
(Width x Height)
32 x 12 34 x 12 32 x 16 58 x 10
24 x 16 60 x 10
Deflection 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45
Ak 1.51 1.42 1.28 1.75 1.64 1.47 1.81 1.70 1.52 2.00 1.88 1.69 2.12 2.00 1.79 2.34 2.10 1.79
Velocity 395 425 470
Total Pressure .006 -007 .008
600 Throw 25-34 13-22 13-19
NC <20 <20 <20
Velocity 430 460 510
Total Pressure .007 -008 .009
650 Throw 26-38 15-22 14-20
NC <20 <20 <20
Velocity 465 495 545 400 425 475
Total Pressure .008 .009 .011 .006 .007 .008
700 Throw 26-40 16-24 15-21 26-38 17-24 14-21
NC <20 <20 <20 <20 <20 <20
Velocity 495 530 585 430 455 510
Total Pressure .009 .010 .013 .007 .008 .009
750 Throw 28-41 17-25 18-21 26-39 17-25 14-21
NC 21 21 22 20 20 21
Velocity 530 565 625 460 485 545 440 470 525 400 425 475
Total Pressure .010 .012 .014 .008 .009 .010 .006 .007 .009 .005 .006 .007
800 Throw 29-41 18-25 16-22 28-40 18-26 15-22 29-41 17-25 15-22 28-40 16-25 15-22
NC 23 24 24 22 23 23 21 22 22 20 20 20
Velocity 595 635 705 515 550 610 495 530 590 450 480 535 425 450 500
Total Pressure .012 .015 .018 .010 .011 .013 .008 .009 .012 .006 .007 .009 .005 .006 .008
900 Throw 30-43 19-27 17-23 30-43 19-27 16-24 30-43 18-27 17-23 30-42 18-27 17-23 30-42 18-27 16-23
NC 27 28 28 28 27 27 25 26 25 24 24 24 23 23 23
Velocity 660 705 780 570 610 680 550 590 670 500 530 590 470 500 560
Total Pressure .015 .018 .022 .012 .013 .016 .010 .011 .014 .008 .009 .011 .006 .007 .010
1000 Throw 32-45 20-28 18-25 32-45 20-29 18-25 32-45 20-28 18-25 32-45 19-28 18-26 32-45 20-29 18-25
NC 31 31 31 30 30 30 28 29 29 27 27 27 25 25 25
Velocity 730 775 860 630 670 750 610 645 725 550 585 650 520 550 615 445 470 525
Total Pressure .019 .022 .027 .015 .016 .019 .012 .014 .014 .010 .011 .013 .007 .008 .012 .005 .006 .009
1100 Throw 33-48 21-29 19-26 33-47 21-30 18-26 34-48 21-29 19-26 33-47 20-29 19-27 33-47 21-30 18-26 33-47 21-30 18-26
NC 34 34 34 33 33 33 32 32 32 30 31 31 28 29 29 24 25 25

11
AIR GRILL AND REGISTER (AG)

36 x 10 28 x 14 30 x 14 30 x 16 50 x 10 24 x 24
30 x 12 22 x 18 24 x 18 40 x 12 42 x 12 36 x 16
SIZES (in.) 20 x 18 20 x 20 36 x 12 48 x 10 36x 14 48 x 12
CFM 48 x 8 40 x 10 60 x 8 28 x 18 72 x 8
(Width x Height)
32 x 12 34 x 12 32 x 16 56 x 10
24 x 16 60 x 10
Deflection 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45 0 22½ 45
Ak 1.51 1.42 1.28 1.75 1.64 1.47 1.81 1.70 1.52 2.00 1.88 1.69 2.12 2.00 1.79 2.48 2.34 2.10
Velocity 795 845 940 685 730 815 665 705 790 600 640 710 565 600 670 485 510 570
Total Pressure .022 .026 .032 .018 .019 .022 .014 .016 .020 .011 .013 .016 .008 .009 .014 .006 .007 .011
1200 Throw 36-50 22-31 19-27 35-49 22-31 19-27 35-50 22-31 19-27 35-49 22-31 19-28 35-49 22-31 19-27 35-49 22-31 19-27
NC 37 37 37 36 36 36 35 35 35 34 34 34 31 32 32 26 27 27
Velocity 860 915 1015 740 790 885 720 765 855 650 690 770 615 650 725 525 555 620
Total Pressure .026 .031 .038 .021 .022 .026 .017 .019 .024 .013 .015 .019 .009 .011 .016 .007 .008 .013
1300 Throw 37-51 23-32 20-28 36-51 23-32 20-28 36-51 23-32 20-28 36-51 23-32 20-29 36-51 23-33 20-28 36-51 23-33 20-28
NC 39 39 10 38 38 38 37 37 37 36 36 36 34 34 34 28 29 29
Velocity 775 825 920 700 745 830 660 700 780 565 600 665
Total Pressure .019 .022 .027 .016 .018 .022 .010 .013 .018 .008 .009 .0015
1400 Throw 38-53 24-33 21-29 37-53 24-33 21-30 38-53 24-33 20-30 37-53 24-33 20-29
NC 40 40 40 39 38 38 36 37 37 30 31 31
Velocity 705 750 835 605 640 715
Total Pressure .011 .015 .021 .009 .010 .017
1500 Throw 39-55 25-35 21-30 39-55 25-35 21-30
NC 38 40 40 32 33 33
Velocity 755 800 895 645 685 760
Total Pressure .013 .017 .024 .010 .011 .019
1600 Throw 40-57 26-36 22-31 40-57 26-36 22-31
NC 41 43 43 34 35 35
Velocity 800 850 950 685 725 810
Total Pressure .015 .019 .027 .011 .012 .021
1700 Throw 41-58 27-38 23-32 41-58 26-37 22-32
NC 44 46 46 36 37 37
Velocity 850 900 1005 725 770 855
Total Pressure .017 .021 .030 .012 .013 .023
1800 Throw 42-60 27-38 23-33 42-60 27-38 23-33
NC 47 49 49 38 39 39
Velocity 768 810 905
Total Pressure .013 .014 .026
1900 Throw 44-62 28-40 24-34
NC 40 41 41
Velocity 805 855 950
Total Pressure .014 .015 .029
2000 Throw 45-63 29-40 25-35
NC 42 43 43
Velocity 965 1025 1140
Total Pressure .020 .022 .042
2400 Throw 49-69 31-44 27-38
NC 50 >50 >50
Velocity 1130 1195 1335
Total Pressure .027 .030 .057
2800 Throw 53-75 34-48 29-41
NC >50 >50 >50
Velocity 1290 1365 1525
Total Pressure .035 .039 .074
3200 Throw 67-80 36-51 31-44
NC >50 >50 >50
Throw Data based upon isothermal
air at 100 and 50 FPM Terminal Velocity

TOTAL PRESSURE ARE IN ICHES OF WATER


N.C. VALUE ARE BASED ON A ROOM ABSORPTION
OF 10dB, RE 10-12 WATTS

12
AIR GRILL AND REGISTER (AG)

Option S: By Screw Option R: By Spring Option S: By Screw (Ceiling)


(Wall or Ceiling) Clip (Wall)

Wall or Wall
Ceiling

Screw
Ceiling
W - 18

W - 18

W - 18

Spring clip
Screw Option P: By Clamp and Strap (Plenum)

Option D: By Screw Option S: By Screw


and collar (Duct) (Wall or Ceiling)
Duct Collar
Wall or Ceiling
W - 18

W - 18

Option D: By Screw and collar (Duct)

Screw Screw Duct Collar

Option C: By Clamp (Ceiling)

Screw

W - 18

13
AIR GRILL AND REGISTER (AG)

14
AIR GRILL AND REGISTER (AG)

15
AIR GRILL AND REGISTER (AG)

16
AIR GRILL FIXED BLADE (AGF)

FIXED BLADES AIR GRILL is a grill of a single set of fixed horizontal (fig. A) or vertical (fig.
B) blades on 45° shape, frame blades are extruded aluminum alloy and polyester powder
coated, used as a side wall return grille.

FIXED BLADES AIR REGISTER is a return air grill with opposed blade damper.

RABIE Customer support department technicians are available to take actual measurements
at site upon request.

1
AIR GRILL FIXED BLADE (AGF)

Opposed Blade Damper

Bush

Frame Horizontal fixed Blade Frame


Horizontal fixed Blade

Fig. A (AGFBH) Fig. B (AGFRH)

Opposed Blade Damper

Vertical fixed Blade Frame Vertical fixed Blade Frame

Fig. C (AGFBV) Fig. D (AGFRV)

2
AIR GRILL FIXED BLADE (AGF)

W = Ceiling or wall opening (width)


W-7

2-7/16”
W - 10

(62)
63/64”
(25)

3/4” 1-5/16” 3/4” 1-5/16”


(20) (33) (20) (33)
W - 18 W - 18

Fig. A (AGFBH) Fig. B (AGFRH)

W-7

2-7/16”
W - 10

(62)
63/64”
(25)

W - 18 1-5/16” W - 18 1-5/16”
(33) (33)

Fig. C (AGFBV) Fig. D (AGFRV)

Size (inches) Velocity (fpm) Size (inches) Velocity (fpm) Size (inches) Velocity (fpm) Size (inches) Velocity (fpm)
12 x 6 300 - 900 18 x 8 300 - 900 30 x 10 300 - 900 18 x 18 300 - 900
16 x 6 300 - 900 20 x 8 300 - 900 32 x 10 300 - 900 24 x 18 300 - 900
18 x 6 300 - 900 24 x 8 300 - 900 36 x 10 300 - 900 30 x 18 300 - 900
20 x 6 300 - 900 30 x 8 300 - 900 12x 12 300 - 900 36 x 18 300 - 900
24 x 6 300 - 900 36 x 8 300 - 900 18 x 12 300 - 900 20 x 20 300 - 900
30 x 6 300 - 900 12 x 10 300 - 900 24 x 12 300 - 900 24 x 20 300 - 900
36 x 6 300 - 900 18 x 10 300 - 900 28 x 12 300 - 900 30 x 20 300 - 900
12 x 8 300 - 900 20 x 10 300 - 900 30 x 12 300 - 900 24 x 24 300 - 900
16 x 8 300 - 900 24 x 10 300 - 900 36 x 12 300 - 900 36 x 24 300 - 900

- Other sizes are available upon request.

3
AIR GRILL FIXED BLADE (AGF)

Face
Velocity 300 400 450 500 550 600 650 700 750 800 900
Listed (fpm)
Sizes
(inches) Static
Pressure Drop 0.008 0.015 0.019 0.023 0.028 0.032 0.038 0.044 0.050 0.056 0.071
(in. w.g.)
CFM 45 60 68 75 82 90 97 105 112 120 135
12 x 6
NC <20 <20 <20 <20 <20 <20 <20 20 21 24 27
CFM 60 80 90 100 110 120 130 140 150 160 180
16 x 6
NC <20 <20 <20 <20 <20 <20 21 22 24 25 28
CFM 75 100 113 125 137 150 163 175 188 200 225
18 x 6
NC <20 <20 <20 <20 <20 <20 22 23 24 26 29
CFM 90 120 135 150 165 180 195 210 225 240 270
20 x 6
NC <20 <20 <20 <20 <20 <20 22 24 25 27 30
CFM 111 148 167 185 203 222 240 259 277 296 333
24 x 6
NC <20 <20 <20 <20 <20 21 23 25 27 29 32
CFM 135 180 203 225 247 270 292 315 338 360 405
30 x 6
NC <20 <20 <20 <20 <20 21 23 25 27 29 32
CFM 162 216 243 270 297 324 351 378 405 432 486
36 x 6
NC <20 <20 <20 <20 21 23 25 27 29 31 34
CFM 60 80 90 100 110 120 130 140 150 160 180
12 x 8
NC <20 <20 <20 <20 <20 <20 20 22 24 25 28
CFM 96 128 144 160 176 192 208 224 240 256 288
16 x 8
NC <20 <20 <20 <20 <20 20 22 24 26 28 31
CFM 111 148 167 185 203 222 240 259 277 296 333
18 x 8
NC <20 <20 <20 <20 <20 21 23 25 27 29 32
CFM 123 164 185 205 225 246 266 287 308 328 369
20 x 8
NC <20 <20 <20 <20 <20 21 23 25 27 29 32
CFM 150 200 225 250 275 300 325 350 375 400 450
24 x 8
NC <20 <20 <20 <20 20 22 24 26 28 30 33
CFM 180 240 270 300 330 360 390 420 450 480 540
30 x 8
NC <20 <20 <20 <20 21 23 25 27 29 31 34
CFM 222 296 333 370 407 444 481 518 555 592 666
36 x 8
NC <20 <20 <20 <20 22 24 26 28 30 32 36
CFM 90 120 135 150 165 180 195 210 225 240 270
12 x 10
NC <20 <20 <20 <20 <20 <20 22 24 25 27 30
CFM 132 176 198 220 242 264 286 308 330 352 396
18 x 10
NC <20 <20 <20 <20 <20 21 24 26 27 29 32
CFM 147 196 220 245 270 294 318 343 367 392 441
20 x 10
NC <20 <20 <20 <20 20 22 24 26 28 30 33
CFM 180 240 270 300 330 360 390 420 450 480 540
24 x 10
NC <20 <20 <20 <20 21 23 25 27 29 31 34
CFM 222 296 333 370 407 444 481 518 555 592 666
30 x 10
NC <20 <20 <20 <20 22 24 26 28 30 32 36
CFM 246 328 369 410 451 492 533 574 615 656 738
32 x 10
NC <20 <20 <20 20 23 25 27 29 31 33 37
CFM 276 368 414 460 506 552 598 644 690 736 828
36 x 10
NC <20 <20 20 23 25 28 30 32 34 36 40
CFM 111 148 167 185 203 222 240 259 277 296 333
12 x 12
NC <20 <20 <20 <20 <20 21 23 25 27 29 32
CFM 162 216 243 270 297 324 351 378 405 432 486
18 x 12
NC <20 <20 <20 <20 21 23 25 27 29 31 34
CFM 222 296 333 370 407 444 481 518 555 592 666
24 x 12
NC <20 <20 <20 <20 22 24 26 28 30 32 36
CFM 261 348 391 435 478 522 565 609 653 696 783
28 x 12
NC <20 <20 <20 20 23 25 27 29 31 33 37
CFM 276 368 414 460 506 552 598 644 690 736 828
30 x 112
NC <20 <20 20 23 25 28 30 32 34 36 40
CFM 336 448 504 560 616 672 728 784 840 896 1008
36 x 12
NC <20 <20 <20 21 24 26 29 31 32 34 38

4
AIR GRILL FIXED BLADE (AGF)

Face
Velocity 300 400 450 500 550 600 650 700 750 800 900
Listed (fpm)
Sizes
(inches) Static
Pressure Drop 0.008 0.015 0.019 0.023 0.028 0.032 0.038 0.044 0.050 0.056 0.071
(in. w.g.)
CFM 195 260 293 325 358 390 423 455 488 520 585
16 x 16
NC <20 <20 <20 <20 22 24 26 28 30 32 36
CFM 249 332 374 415 456 498 539 581 622 664 747
18 x 18
NC <20 <20 <20 20 23 25 27 29 31 33 37
CFM 339 452 509 565 622 678 735 791 847 904 1017
24 x 18
NC <20 <20 <20 21 23 26 28 31 32 34 38
CFM 420 560 630 700 770 840 910 980 1050 1120 1260
30 x 18
NC <20 <20 20 23 25 28 30 32 34 36 40
CFM 513 684 770 855 940 1026 1111 1197 1282 1368 1539
36 x 18
NC <20 <20 21 24 27 29 31 33 35 37 41
CFM 312 416 468 520 572 624 676 728 780 832 936
20 x 20
NC <20 <20 20 21 24 26 28 30 32 34 38
CFM 381 508 572 635 699 762 825 889 952 1016 1143
24 x 20
NC <20 <20 20 22 25 27 29 31 33 35 39
CFM 471 628 707 785 863 942 1020 1099 1177 1256 1413
30 x 20
NC <20 <20 20 23 26 28 30 32 34 36 40
CFM 456 608 684 760 836 912 988 1064 1140 1216 1368
24 x 24
NC <20 <20 21 23 26 28 30 32 34 36 40
CFM 687 916 1030 1145 1260 1374 1488 1603 1717 1832 2061
36 x 24
NC <20 <20 23 25 28 30 32 34 36 38 42

5
AIR GRILL FIXED BLADE (AGF)

Option R: By Spring Option S: By Screw


Clip (Wall) Option P: By Clamp and Strap (Plenum)

Wall Wall or
Ceiling
W - 18

W - 18

Option S: By Screw (Wall or Ceiling)


Spring clip

Screw

Ceiling Screw

Option C: By Clamp (Ceiling)


W - 18

Option D: By Screw and collar (Duct)

Duct Collar

Screw

W - 18

6
AIR GRILL FIXED BLADE (AGF)

7
AIR GRILL FIXED BLADE (AGF)

8
DOOR GRILL (DG)

3/4” 1-3/16”
(20) (30)
Max.2-3/16”
Min.1”

Length X Width

DOOR GRILL is a grill with V shape inverted blades assembled horizontally with 3/4”
opening on center, frame and blades are extruded aluminum alloy and polyester powder
coated, suitable for doors, walls or partitions.

Sizes
(Use any combination of length & width)
Length Width
(Inches) (Inches)
(A) (B)
20 4
24 8
32 12
16

- Non standard sizes are available upon request.

1
DOOR GRILL (DG)

Core Velocity
300 400 450 500 550 600 650 700 750 800
(fpm)
Listed Static Pressure
sizes 0.021 0.035 0.044 0.053 0.065 0.076 0.089 0.103 0.115 0.113
(in. w.g.)
(inches)
Area Factor
AIR CAPACITY (cfm)
(Sq. ft.)
10 x 6 0.15 45 60 68 75 82 90 98 105 112 120
12 x 6 0.18 54 72 81 90 99 108 117 126 135 144
16 x 6 0.25 75 100 112 125 137 150 162 175 187 200
18 x 6 0.28 84 112 126 140 154 168 182 196 210 224
20 x 6 0.32 96 128 144 160 176 192 208 224 240 256
24 x 6 0.39 117 156 175 195 214 234 253 273 292 312
10 x 8 0.21 63 84 94 105 115 126 136 147 157 168
12 x 8 0.26 78 104 117 130 143 156 169 182 195 208
16 x 8 0.35 105 140 157 175 192 210 227 245 262 280
18 x 8 0.40 120 160 180 200 220 240 260 280 300 320
24 x 8 0.55 165 220 247 275 302 330 357 385 412 440
30 x 8 0.68 204 272 306 340 374 408 442 476 510 544
10 x 10 0.20 81 108 121 135 148 162 175 189 202 216
12 x 10 0.36 108 144 162 180 198 216 234 252 270 288
16 x 10 0.46 138 184 207 230 253 276 299 322 345 368
18 x 10 0.52 156 208 234 260 286 312 338 364 390 416
20 x 10 0.58 174 232 261 290 319 348 377 406 435 464
24 x 10 0.70 210 280 315 350 385 420 455 490 525 560
12 x 12 0.41 123 164 184 205 225 246 266 287 307 328
16 x 12 0.56 168 224 252 280 308 336 364 392 420 448
18 x 12 0.64 192 256 288 320 352 384 416 448 480 512
20 x 12 0.71 213 284 319 355 390 426 461 497 532 568
24 x 12 0.86 258 344 387 430 473 516 559 602 645 688
30 x 12 1.08 324 432 486 540 594 648 702 756 810 864
24 x 16 1.18 354 472 531 590 649 708 767 826 885 944
18 x 18 0.96 288 384 432 480 528 576 624 672 720 768
24 x 18 1.30 390 520 585 650 715 780 845 910 975 1040
30 x 18 1.69 507 676 760 845 929 1014 1098 1183 1267 1352
24 x 24 1.78 534 712 801 890 979 1068 1157 1246 1335 1424
30 x 24 2.28 684 912 1026 1140 1254 1368 1482 1596 1710 1824
30 x 30 2.88 864 1152 1296 1440 1584 1728 1872 2016 2160 2304

2
DOOR GRILL (DG)

Door or partition

Frame

Core

Screw (Optional)

3
DOOR GRILL (DG)

4
EGG CRATE GRILL (ECG)

Grill core is made of aluminum strips assembled to from equally distributed and sized
square cells with 90% effective area permits better performance (low pressure drop and
low noise level), frame is made from extruded aluminum alloy and polyester powder
coated.
The egg crate are either ceiling or wall mounted air terminal devices used as exhaust air
grill for domestic and industrial application.

1
EGG CRATE GRILL (ECG)

W = Ceiling or wall opening (width)

W - 10

63/64”
(25)
1/2”
(13)
W - 18 1-3/16”
(30)

W - 15

2-7/16”
63/64”
(25)

1/2”
(13)
W - 18 1-3/16”
(30)
H

DETAIL - “A”
“A”
Listed grid size : L xW xH
ECG Example : ½” x ½” x ½”

2
EGG CRATE GRILL (ECG)

Neck Core Core Velocity (fpm) 300 400 500 600 700 800 1000 1200 1400
Size Area Velocity Pressure (in. w.g.) .006 .010 .016 .022 .031 .040 .062 .090 .122
(inches) (Sq. Ft.) Negative SP (in w.g.) .016 .026 .042 .059 .082 .106 .165 .238 .323
CFM 52 69 86 103 120 138 172 206 241
6x6 0.172
NC 25 28 30 32 33 34 36 38 40
CFM 74 99 124 149 174 198 248 298 347
8x6 0.248
NC 24 27 29 31 32 34 36 38 39
CFM 93 125 156 187 218 250 312 374 437
10 x 6 0.312
NC 23 26 28 30 32 33 35 37 38
CFM 116 155 194 232 271 310 387 464 542
12 x 6 0.387
NC 23 26 28 30 31 33 35 37 38
CFM 135 181 226 271 316 361 452 542 633
14 x 6 0.452
NC 23 26 28 30 31 32 35 36 38
CFM 155 207 259 310 362 414 517 620 724
16 x 6 0.517
NC 23 25 28 29 31 32 34 36 38
CFM 178 237 296 355 414 474 592 710 829
18 x 6 0.592
NC 22 25 27 29 31 32 34 36 37
CFM 197 263 329 394 460 526 657 788 920
20 x 6 0.657
NC 22 25 27 29 30 32 34 36 37
CFM 239 319 398 478 558 638 797 956 1116
24 x 6 0.797
NC 22 24 27 28 30 31 33 35 37
CFM 281 374 468 562 655 749 936 1123 1310
28 x 6 0.936
NC 21 24 26 28 30 31 33 35 36
CFM 320 426 533 640 746 853 1066 1279 1492
32 x 6 1.066
NC 21 24 26 28 29 31 33 35 36
CFM 361 482 603 723 844 964 1205 1446 1687
36 x 6 1.205
NC 21 24 26 28 29 30 33 34 36
CFM 404 538 673 807 942 1076 1345 1614 1883
40 x 6 1.345
NC 21 23 26 27 29 30 32 34 36
CFM 487 650 813 975 1137 1300 1625 1950 2275
48 x 6 1.625
NC 20 23 25 27 29 30 32 34 35
CFM 103 138 172 206 241 275 344 413 482
8x8 0.344
NC 23 26 28 30 31 33 35 37 38
CFM 132 176 220 267 309 353 441 529 617
10 x 8 0.441
NC 23 26 28 30 31 32 35 36 38
CFM 158 211 264 316 369 422 527 632 738
12 x 8 0.527
NC 22 25 27 29 31 32 34 36 37
CFM 187 250 312 374 437 499 624 749 874
14 x 8 0.624
NC 22 25 27 29 30 32 34 36 37
CFM 216 288 360 433 505 577 721 865 1009
16 x 8 0.721
NC 22 24 27 28 30 31 33 35 37
CFM 245 327 409 491 573 654 818 982 1145
18 x 8 0.818
NC 21 24 26 28 30 31 33 35 36
CFM 274 366 457 549 640 732 915 1098 1281
20 x 8 0.915
NC 21 24 26 28 29 31 33 35 36
CFM 333 444 555 665 776 887 1109 1331 1557
24 x 8 1.109
NC 21 24 26 28 29 30 33 34 36
CFM 391 521 651 781 911 1042 1302 1562 1823
28 x 8 1.302
NC 21 23 26 27 29 30 32 34 36
CFM 445 594 743 891 1039 1188 1485 1782 2079
32 x 8 1.485
NC 20 23 25 27 29 30 32 34 35
CFM 504 672 840 1007 1175 1343 1679 2015 2351
36 x 8 1.679
NC 20 23 25 27 28 30 32 34 35
CFM 562 749 936 1123 1311 1498 1873 2248 2622
40 x 8 1.873
NC 20 23 25 27 28 29 32 33 35

3
EGG CRATE GRILL (ECG)

Neck Core Core Velocity (fpm) 300 400 500 600 700 800 1000 1200 1400
Size Area Velocity Pressure (in. w.g.) .006 .010 .016 .022 .031 .040 .062 .090 .122
(inches) (Sq. Ft.) Negative SP (in w.g.) .016 .026 .042 .059 .082 .106 .165 .238 .323
CFM 675 900 1125 1350 1575 1800 2250 2700 3150
48 x 8 2.250
NC 19 22 24 26 28 29 31 33 34
CFM 168 224 280 336 392 448 560 672 784
10 x 10 0.560
NC 22 25 27 29 31 32 34 36 37
CFM 200 267 333 400 467 534 667 800 934
12 x 10 0.667
NC 22 25 27 29 30 32 34 36 37
CFM 242 323 403 484 565 646 807 968 1130
14 x 10 0.807
NC 22 24 27 28 30 31 33 35 37
CFM 278 370 463 556 648 741 926 1111 1296
16 x 10 0.926
NC 21 24 26 28 30 31 33 35 36
CFM 316 422 527 632 738 843 1054 1265 1476
18 x 10 1.054
NC 21 24 26 28 29 31 33 35 36
CFM 355 474 592 710 829 947 1184 1421 1658
20 x 10 1.184
NC 21 24 26 28 29 30 33 34 36
CFM 426 568 710 853 995 1137 1421 1705 1989
24 x 10 1.421
NC 20 23 25 27 29 30 32 34 35
CFM 497 663 829 995 1161 1326 1658 1990 2321
28 x 10 1.658
NC 20 23 25 27 28 30 32 34 35
CFM 571 762 952 1143 1333 1524 1905 2286 2667
32 x 10 1.905
NC 20 23 25 27 28 30 32 34 35
CFM 646 861 1076 1292 1507 1722 2153 2584 3014
36 x 10 2.153
NC 20 23 25 27 28 29 32 33 35
CFM 720 960 1200 1440 1680 1920 2400 2880 3360
40 x 10 2.400
NC <20 22 24 26 28 29 31 33 34
CFM 865 1154 1442 1731 2019 2308 2885 3462 4039
48 x 10 2.885
NC <20 22 24 26 27 29 31 32 34
CFM 249 332 414 497 580 663 829 995 1161
12 x 12 0.829
NC 21 24 26 28 30 31 33 35 36
CFM 294 392 489 587 685 783 979 1175 1371
14 x 12 0.979
NC 21 24 26 28 29 31 33 35 36
CFM 339 452 565 678 791 904 1130 1356 1582
16 x 12 1.130
NC 21 24 26 28 29 30 33 34 36
CFM 384 512 640 767 897 1025 1281 1537 1793
18 x 12 1.281
NC 21 23 26 27 29 30 32 34 36
CFM 430 573 716 859 1002 1146 1432 1718 2005
20 x 12 1.432
NC 20 23 25 27 29 30 32 34 35
CFM 520 693 866 1039 1213 1386 1733 2080 2426
24 x 12 1.733
NC 20 23 25 27 28 30 32 34 35
CFM 610 814 1017 1220 1424 1627 2034 2441 2848
28 x 12 2.034
NC 20 23 25 27 28 29 32 33 35
CFM 697 930 1162 1395 1627 1860 2325 2790 3255
32 x 12 2.325
NC <20 22 24 26 28 29 31 33 34
CFM 788 1050 1313 1575 1838 2100 2626 3151 3676
36 x 12 2.626
NC <20 22 24 26 27 29 31 33 34
CFM 878 1171 1464 1757 2050 2342 2928 3514 4099
40 x 12 2.928
NC <20 22 24 26 27 29 31 32 34
CFM 1056 1408 1760 2112 2464 2816 3520 4224 4928
48 x 12 3.520
NC <20 21 24 25 27 28 30 32 34
CFM 349 465 581 697 813 930 1162 1394 1627
14 x 14 1.162
NC 21 24 26 28 29 30 33 34 36
CFM 400 534 667 801 934 1068 1335 1602 1869
16 x 14 1.335
NC 21 23 26 27 29 30 32 34 36

4
EGG CRATE GRILL (ECG)

Neck Core Core Velocity (fpm) 300 400 500 600 700 800 1000 1200 1400
Size Area Velocity Pressure (in. w.g.) .006 .010 .016 .022 .031 .040 .062 .090 .122
(inches) (Sq. Ft.) Negative SP (in w.g.) .016 .026 .042 .059 .082 .106 .165 .238 .323
CFM 452 603 753 904 1055 1206 1507 1808 2110
18 x 14 1.507
NC 20 23 25 27 29 30 32 34 35
CFM 504 672 839 1007 1175 1343 1679 2015 2351
20 x 14 1.679
NC 20 23 25 27 28 30 32 34 35
CFM 610 814 1017 1220 1424 1627 2034 2441 2848
24 x 14 2.034
NC 20 23 25 27 28 29 32 33 35
CFM 717 956 1195 1434 1673 1912 2390 2868 3346
28 x 14 2.390
NC <20 22 24 26 28 29 31 33 34
CFM 823 1098 1372 1647 1921 2196 2745 3294 3843
32 x 14 2.745
NC <20 22 24 26 27 29 31 33 34
CFM 930 1240 1550 1860 2170 2480 3100 3720 4340
36 x 14 3.100
NC <20 22 24 26 27 29 31 32 34
CFM 1036 1382 1727 2073 2418 2764 3455 4146 4837
40 x 14 3.455
NC <20 21 24 25 27 28 30 32 34
CFM 1246 1662 2077 2493 2908 3324 4155 4986 5817
48 x 14 4.155
NC <20 21 23 25 27 28 30 32 33
CFM 462 616 769 923 1077 1231 1539 1847 2155
16 x 16 1.539
NC 20 23 25 27 29 30 32 34 35
CFM 520 693 866 1040 1213 1386 1733 2080 2426
18 x 16 1.733
NC 20 23 25 27 28 30 32 34 35
CFM 584 779 974 1169 1364 1558 1948 2338 2727
20 x 16 1.948
NC 20 23 25 27 28 29 32 33 35
CFM 704 938 1173 1408 1642 1877 2346 2815 3284
24 x 16 2.346
NC <20 22 24 26 28 29 31 33 34
CFM 826 1102 1377 1653 1928 2204 2755 3306 3857
28 x 16 2.755
NC <20 22 24 26 27 29 31 33 34
CFM 945 1266 1582 1899 2215 2532 3165 3798 4431
32 x 16 3.165
NC <20 22 24 26 27 29 31 32 34
CFM 1072 1430 1787 2144 2502 2859 3574 4289 5004
36 x 16 3.574
NC <20 21 24 25 27 28 30 32 34
CFM 1192 1589 1986 2383 2780 3178 3972 4766 5561
40 x 16 3.972
NC <20 21 23 25 27 28 30 32 33
CFM 1437 1916 2395 2874 3353 3832 4790 5748 6706
48 x 16 4.790
NC <20 21 23 25 26 28 30 32 33
CFM 591 788 985 1182 1379 1576 1970 2364 2758
18 x 18 1.970
NC 20 23 25 27 28 29 32 33 35
CFM 659 878 1098 1318 1537 1757 2196 2635 3074
20 x 18 2.196
NC <20 22 24 26 28 29 31 33 34
CFM 798 1064 1330 1595 1861 2127 2659 3190 3723
24 x 18 2.659
NC <20 22 24 26 27 29 31 33 34
CFM 936 1248 1560 1873 2185 2497 3121 3745 4369
28 x 18 3.121
NC <20 22 24 26 27 29 31 32 34
CFM 1075 1434 1792 2150 2509 2867 3584 4301 5018
32 x 18 3.584
NC <20 21 24 25 27 28 30 32 34
CFM 1214 1619 2023 2428 2833 3238 4047 4856 5666
36 x 18 4.047
NC <20 21 23 25 27 28 30 32 33
CFM 1350 1800 2250 2700 3150 3600 4500 5400 6300
40 x 18 4.499
NC <20 21 23 25 26 28 30 32 33
CFM 1627 2170 2712 3255 3797 4340 5425 6510 7595
48 x 18 5.425
NC <20 21 23 24 26 27 29 31 33
CFM 736 982 1227 1472 1718 1963 2454 2945 3436
20 x 20 2.454
NC <20 22 24 26 28 29 31 33 34

5
EGG CRATE GRILL (ECG)

Neck Core Core Velocity (fpm) 300 400 500 600 700 800 1000 1200 1400
Size Area Velocity Pressure (in. w.g.) .006 .010 .016 .022 .031 .040 .062 .090 .122
(inches) (Sq. Ft.) Negative SP (in w.g.) .016 .026 .042 .059 .082 .106 .165 .238 .323
CFM 891 1188 1485 1783 2078 2377 2971 3565 4159
24 x 20 2.971
NC <20 22 24 26 27 29 31 32 34
CFM 1046 1395 1743 2092 2441 2790 3487 4184 4882
28 x 20 3.487
NC <20 21 23 25 27 28 30 32 33
CFM 1201 1602 2002 2402 2803 3203 4004 4805 5605
32 x 20 4.004
NC <20 21 23 25 27 28 30 32 33
CFM 1353 1804 2255 2706 3157 3608 4510 5412 6314
36 x 20 4.510
NC <20 21 23 25 26 28 30 32 33
CFM 1508 2011 2513 3016 3519 4022 5027 6032 7038
40 x 20 5.027
NC <20 21 23 24 26 27 29 31 33
CFM 1818 2424 3030 3636 4242 4848 6060 7272 8484
48 x 20 6.060
NC <20 20 22 24 26 27 29 31 33
CFM 1078 1438 1797 2157 2516 2876 3595 4314 5033
24 x 24 3.595
NC <20 21 24 25 27 28 30 32 34
CFM 1266 1688 2109 2531 2953 3375 4219 5063 5907
28 x 24 4.219
NC <20 21 23 25 27 28 30 32 33
CFM 1450 1933 2416 2899 3383 3866 4833 5800 6766
32 x 24 4.833
NC <20 21 23 25 26 28 30 32 33
CFM 1637 2183 2728 3274 3820 4365 5457 6548 7640
36 x 24 5.457
NC <20 21 23 24 26 27 29 31 33
CFM 1824 2432 3040 3649 4257 4865 6081 7297 8513
40 x 24 6.081
NC <20 20 22 24 26 27 29 31 33
CFM 2199 2932 3665 4398 5131 5864 7330 8796 10,262
48 x 24 7.330
NC <20 20 22 24 26 27 29 31 33
CFM 1482 1976 2470 2965 3459 3953 4941 5929 6917
28 x 28 4.941
NC <20 21 23 25 26 28 30 32 33
CFM 1702 2269 2836 3403 3970 4538 5672 6806 7941
32 x 28 5.672
NC <20 21 23 24 26 27 29 31 33
CFM 1921 2562 3202 3842 4483 5123 6404 7685 8966
36 x 28 6.404
NC <20 20 22 24 26 27 29 31 33
CFM 2141 2854 3568 4282 4995 5709 7136 8563 9990
40 x 28 7.136
NC <20 20 22 24 26 27 29 31 32
CFM 2577 3436 4294 5153 6012 6871 8589 10,307 12,025
48 x 28 8.589
NC <20 <20 21 23 25 27 29 31 32
CFM 1954 2605 3256 3907 4558 5210 6512 7814 9117
32 x 32 6.512
NC <20 20 22 24 26 27 29 31 32
CFM 2206 2941 3676 4411 5146 5882 7352 8822 10,293
36 x 32 7.352
NC <20 20 22 24 26 27 29 31 32
CFM 2457 3276 4095 4914 5734 6553 8191 9829 11,467
40 x 32 8.191
NC <20 <20 22 24 26 27 29 30 31
CFM 2958 3943 4929 5915 6901 7887 9859 11,831 13,803
48 x 32 9.859
NC <20 <20 22 24 26 27 29 30 31
CFM 2490 3320 4150 4980 5810 6640 8300 9960 11,620
36 x 36 8.299
NC <20 <20 21 23 25 27 29 31 32
CFM 2770 3694 4618 5541 6464 7388 9235 11,802 12,929
40 x 36 9.235
NC <20 <20 22 24 26 27 29 30 31
CFM 3339 4452 5565 6678 7791 8904 11,130 13,356 15,582
48 x 36 11.130
NC <20 <20 22 24 26 27 28 30 31
CFM 3087 4116 5145 6174 7203 8232 10,290 12,348 14,406
40 x 40 10.290
NC <20 <20 22 24 26 27 29 30 31
CFM 3720 4960 6200 7440 8680 9920 12,400 14,880 17,350
48 x 40 12.400
NC <20 <20 22 24 26 27 28 30 32
CFM 4479 5972 7464 8957 10,450 11,943 14,929 17,915 20,900
48 x 48 14.929
NC <20 <20 21 23 25 27 28 30 32
- NC values are based on room absorption of 10dB, re 10-12 Watts.

6
EGG CRATE GRILL (ECG)

Option S: By Screw (Wall or Ceiling)

W - 10 Screw

W - 18

Option C: By Clamp (Ceiling)

Option P: By Clamp and Strap (Plenum)

7
EGG CRATE GRILL (ECG)

8
ACCES DOOR GRILL (AD)

Frame + 50mm

45/64”
(18)
Frame

Safety wire

AG face

Door blades are seated in a fixed position at 45°, frame has typical wall thickness of 1/16”,
both are made from extruded aluminum alloy and are polyester powder coated, air filter
available on request.

Listed size
Size CFM Size CFM
(inches) Range (inches) Range

10 x 6 60 - 100 24 x 24 455 - 1065

10 x 8 80 - 140 30 x 12 470 - 845

12 x 6 70 - 120 30 x 18 280 - 700

12 x 8 100 - 200 30 x 24 580 - 1160

12 x 12 185 - 295 36 x 18 855 - 1370

18 x 6 105 - 210 36 x 24 915 - 1830

18 x 12 110 - 215 36 x 30 1440 - 2305

18 x 18 250 - 500 48 x 24 1530 - 2755

24 x 12 370 - 665 48 x 30 1540 - 3080

24 x 18 340 - 565 48 x 36 1850 - 3240

1
ACCES DOOR GRILL (AD)

45° Blade Angle


Face Velocity (fpm)
Listed 200 300 400 500 600 700 800 900
Area Factor
Sizes
(Sq. ft.) Static Pressure Drop (in. w.g.)
(inches)
0.004 0.008 0.015 0.023 0.032 0.044 0.056 0.071
Air Capacity (cfm)
10 x 6 0.143 57 72 86 100
10 x 8 0.200 80 100 120 140
12 x 6 0.170 68 85 102 119
12 x 8 0.250 100 125 150 175 200
12 x 12 0.370 185 222 259 296
18 x 6 0.260 104 130 156 182 208
18 x 12 0.540 108 162 216
18 x 18 0.830 249 332 415 498
24 x 12 0.740 370 444 518 592 666
24 x 18 1.130 339 452 565
24 x 24 1.520 456 608 760 912 1064
30 x 12 0.940 470 564 658 752 846
30 x 18 1.400 280 420 560 700
30 x 24 1.930 579 772 965 1158
36 x 18 1.710 855 1026 1197 1368
36 x 24 2.290 916 1145 1374 1603 1832
36 x 30 2.880 1440 1728 2016 2304
48 x 24 3.060 1530 1836 2142 2448 2754
48 x 30 3.850 1540 1925 2310 2695 3080
48 x 36 4.630 1852 2315 2778 3241

2
ACCES DOOR GRILL (AD)

Frame + 50mm

45/64”
(18)
Frame

Safety wire

ECG face

Door grid cores are all aluminum, mechanically locked in margins, frame has a typical wall
thickness of 1/16”, made from extruded aluminum alloy and polyester powder coated, air
filter is available on request.

Listed size
Size CFM Size CFM
(inches) Range (inches) Range

10 x 6 90 - 250 24 x 24 720 - 2875

10 x 8 130 - 350 30 x 12 885 - 2215

12 x 6 115 - 310 30 x 18 685 - 2055

12 x 8 160 - 475 30 x 24 925 - 3240

12 x 12 330 - 745 36 x 18 1620 - 3640

18 x 6 180 - 530 36 x 24 1635 - 4910

18 x 12 255 - 640 36 x 30 2820 - 6344

18 x 18 395 - 1380 48 x 24 2932 - 7330

24 x 12 690 - 1730 48 x 30 2810 - 8430


24 x 18 530 - 1595 48 x 36 3340 - 8905

3
ACCES DOOR GRILL (AD)

Core Velocity (fpm)


Listed 200 300 400 500 600 700 800 900 1000
Area Factor
Sizes
(Sq. ft.) Static Pressure Drop (in. w.g.)
(inches)
0.010 0.016 0.026 0.042 0.059 0.082 0.106 0.130 0.165
10 x 6 0.312 93 125 156 187 218 250
10 x 8 0.441 132 176 220 264 309 353
12 x 6 0.387 116 155 194 232 271 310
12 x 8 0.527 158 211 264 316 369 422 474
12 x 12 0.829 332 414 497 580 663 746
18 x 6 0.592 178 237 296 355 414 474 533
18 x 12 1.281 256 384 512 640
18 x 18 1.970 394 591 788 985 1182 1379
24 x 12 1.733 693 866 1039 1213 1386 1560 1733
24 x 18 2.659 532 798 1064 1330 1595
24 x 24 3.595 719 1078 1438 1797 2157 2516 2876
30 x 12 2.215 886 1108 1329 1550 1772 1994 2215
30 x 18 3.424 685 1027 1370 1712 2054
30 x 24 4.632 926 1390 1853 2316 2779 3242
36 x 18 4.047 1619 2023 2428 2833 3238 3642
36 x 24 5.457 1637 2183 2728 3274 3820 4365 4911
36 x 30 7.049 2820 3525 4229 4934 5639 6344
48 x 24 7.330 2932 3665 4398 5131 5864 6597 7330
48 x 30 9.365 2810 3746 4683 5619 6555 7492 8428
48 x 36 11.130 3339 4452 5565 6678 7791 8904

4
ACCES DOOR GRILL (AD)

Frame + 50mm

45/64”
(18)
Frame

Safety wire

Perforated face

Door perforated face is made of white powder coated aluminum sheet 5/32” diameter holes
a pitch of 15/64” and 45% free area, frame has a typically wall thickness of 1/16” made from
extruded aluminum alloy and polyester powder coated, air filter available on request.

Listed size
Size CFM Size CFM
(inches) Range (inches) Range

10 x 6 100 - 200 24 x 24 750 - 2250

10 x 8 140 - 275 30 x 12 915 - 1830

12 x 6 125 - 250 30 x 18 700 - 1400

12 x 8 180 - 360 30 x 24 945 - 2830

12 x 12 350 - 615 36 x 18 1690 - 2955

18 x 6 190 - 440 36 x 24 2275 - 3980

18 x 12 270 - 535 36 x 30 2865 - 5010

18 x 18 415 - 1040 48 x 24 3050 - 6100

24 x 12 730 - 1455 48 x 30 3840 - 7680

24 x 18 555 - 1110 48 x 36 4625 - 9250

5
ACCES DOOR GRILL (AD)

Core Velocity (fpm)


Listed 200 300 400 500 600 700 800
Area Factor
Sizes Static Pressure Drop (in. w.g.)
(Sq. ft.)
(inches) 0.012 0.032 0.055 0.087 0.123 0.170 0.221
Air Capacity (cfm)
10 x 6 0.34 102 136 170 204
10 x 8 0.46 138 184 230 276
12 x 6 0.41 123 164 205 246
12 x 8 0.60 180 240 300 360
12 x 12 0.88 352 440 528 616
18 x 6 0.63 189 252 315 378 441
18 x 12 1.34 268 402 536
18 x 18 2.08 416 624 832 1040
24x12 1.82 728 910 1092 1274 1456
24 x 18 2.78 556 834 1112
24 x 24 3.75 750 1125 1500 1875 2250
30 x 12 2.29 916 1145 1374 1603 1832
30 x 18 3.50 700 1050 1400
30 x 24 4.72 944 1416 1888 2360 2832
36 x 18 4.22 1688 2110 2532 2954
36 x 24 5.69 2276 2845 3414 3983
36 x 30 7.16 2864 3580 4296 5012
48 x 24 7.63 3052 3815 4578 5341 6104
48 x 30 9.60 3839 4799 5759 6719 7678
48 x 36 11.57 4624 5783 6940 8096 9253

6
ACCES DOOR GRILL (AD)

Frame + 50mm

45/64”
(18)
Frame

Safety wire

Ceiling Access Door ADC is a customized ceiling access door frame that can adopt any
diffuser/grill type or false ceiling tile.
The frame is supplied with mini latches that allow for easy open/close operation, and
optionally with safety wire to prevent accidental falling of the cover.

7
ACCES DOOR GRILL (AD)

Safety wire

Frame - 9mm Ceiling

Frame (Opening –5mm)

Frame + 50mm

Ceiling
Safety wire

Hook

8
CEILING DIFFUSER (CD)

RABIE provides a wide range of ceiling diffusers to suit customer requirements of ceiling
air distribution, which can be supply or return, square or rectangular shape, with one,
two, three or four way patterns.
Diffusers core is fully removable, opposed blades damper can be installed to the frame
with N-clips and is lever operated from the face.
Core and frame are made of extruded aluminum alloy and polyester powder coated to
RAL9016 (standard) and others upon request.

1
CEILING DIFFUSER (CD)

1 way discharge

Square (CDSX-1) Rectangular by width Rectangular by length


(CDRX-1W) (CDRX-1L)

2 way discharge

Corner (CDSX-2C) Square (CDSX-2) Rectangular by width Rectangular by length


(CDRX-2W) (CDRX-2L)

3 way discharge 4 way discharge

Square (CDSX-3) Rectangular by width Square (CDSX-4) Rectangular (CDRX-4)


(CDRX-3W)

X:
S Supply (with OBD)
R Return (without OBD)

2
CEILING DIFFUSER (CD)

Square (CDS-4) Return Rectangular (CDR-4) Return

NECK

NECK
FACE

FACE

1-3/4”
1-3/4”

Square (CDS-4) Supply Rectangular (CDR-4) Supply

NECK
NECK

FACE
FACE

3-1/4” 3-1/4”

3
CEILING DIFFUSER (CD)

When the required face is larger than the neck size by more than 5 1/2” (140mm), then T-
Bar Option is used.
Please specify Face and Neck dimensions.

4
CEILING DIFFUSER (CD)

Listed Sizes (Square Ceiling Diffusers)

DIMENSIONS
NECK FACE CFM
Size
in. (mm) in. (mm) Range
6x6 6-5/16” (152) 11-13/16” (292) 50 - 225
9x9 8-7/8” (229) 14-3/8” (369) 100 - 500
12 x 12 12-13/64” (305) 17-23/32” (445) 200 - 900
15 x 15 14-31/32” (381) 20-1/2” (521) 300 - 1400
18 x 18 18-1/32” (457) 23-1/2” (597) 450 - 2000
21 x 21 20-7/8” (533) 26-3/8” (673) 600 - 2750
24 x 24 23-13/16” (610) 29-3/8” (750) 800 - 3600

Listed Sizes (Rectangular Ceiling Diffusers)

DIMENSIONS
Horizontal Vertical CFM Horizontal Vertical CFM
Size Size
in. (mm) in. (mm) Range in. (mm) in. (mm) Range

9x6 9 (228.6) 6 (152.4) 75 -335 18 x 9 18 (457.2) 9 (228.6) 225 - 1010

12 x 6 12 (304.8) 6 (152.4) 100 - 450 18 x 12 18 (457.2) 12 (304.8) 300 - 1350


12 x 9 12 (304.8) 9 (228.6) 150 - 675 21 x 6 21 (533.4) 6 (152.4) 175 - 785

15 x 6 15 (381.0) 6 (152.4) 152 - 560 21 x 9 21 (533.4) 9 (228.6) 260 - 1180

15 x 9 15 (381.0) 9 (228.6) 190 - 845 24 x 6 24 (609.6) 6 (152.4) 200 - 900

15 x 12 15 (381.0) 12 (304.8) 250 - 1125 24 x 9 24 (609.6) 9 (228.6) 300 - 1350

18 x 6 18 (457.2) 6 (152.4) 150 - 675 24 x 12 24 (609.6) 12 (304.8) 400 - 1800

Velocity Pressure Conversion Table

CORE VELOCITY VELOCITY PRESSURE


(FPM) (INCHES W.G.)
250 0.004
300 0.006
350 0.008
400 0.010
450 0.013
500 0.016
550 0.019
600 0.022
650 0.026
700 0.031
750 0.035
800 0.040

5
CEILING DIFFUSER (CD)

CDSS-1 (ONE WAY)


Area Factor Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900

Size (AK) Velocity Pressure


.003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(in. w.g.)
(inch) Neck Area
Total Pressure
(sq.ft.) (in. w.g.)
.015 .024 0.34 .046 .060 .094 .136 .184 .240 .305

Ak = .085 CFM 50 63 75 88 100 125 150 175 200 225


6x6 THROW 7-10 8-12 10-15 12-17 14-19 17-21 19-23 20-24 22-26 23-27
0.250 NC <20 <20 <20 <20 <20 <20 23 27 31 35
Ak = .177 CFM 110 140 170 195 225 280 335 395 450 505
9x9 THROW 9-13 11-16 14-18 16-19 17-21 19-23 21-25 22-27 24-29 26-30
0.562 NC <20 <20 <20 <20 <20 21 27 31 35 39
Ak = .306 CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 THROW 11-16 14-18 16-19 17-21 18-22 20-25 22-27 24-29 26-31 27-33
1.000 NC <20 <20 <20 <20 <20 23 30 34 38 42
Ak = .472 CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 THROW 13-17 15-19 17-20 18-22 19-23 22-26 24-28 25-30 27-32 29-34
1.56 NC <20 <20 <20 <20 21 26 32 36 40 44
Ak = .674 CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 THROW 14-18 16-19 17-21 19-23 20-24 23-27 25-30 27-32 29-34 30-36
2.25 NC <20 <20 <20 21 23 28 34 38 42 45
Ak = 914 CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 THROW 15-18 17-20 18-22 20-24 21-25 24-28 26-31 28-33 30-35 32-37
3.06 NC <20 <20 <20 22 23 30 36 40 44 49
Ak = 1.22 CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 THROW 15-19 17-21 19-23 20-25 22-26 24-29 27-32 29-34 31-37 33-39
4.00 NC <20 <20 20 23 24 31 37 41 45 50

CDSS-2(TWO WAY)
Area Factor Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900

Size (AK) Velocity Pressure .003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(in. w.g.)
(inch) Neck Area
Total Pressure
(sq.ft.) .014 .022 .032 .043 .057 .088 .128 .174 .228 .286
(in. w.g.)
Ak = .085 CFM 50 63 75 88 100 125 150 175 200 225
6x6 THROW 5-8 6-9 8-11 9-13 10-14 12-17 15-21 18-23 20-25 22-27
0.250 NC <20 <20 <20 <20 <20 <20 23 27 31 35
Ak = .177 CFM 110 140 170 195 225 280 335 395 450 505
9x9 THROW 7-10 8-12 10-15 12-16 14-19 17-22 20-24 21-26 23-27 24-29
0.562 NC <20 <20 <20 <20 <20 21 27 31 35 39
Ak = .306 CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 THROW 9-12 11-15 13-18 15-20 17-21 20-24 22-26 23-28 25-30 26-32
1.000 NC <20 <20 <20 <20 <20 23 30 34 38 42
Ak = .472 CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 THROW 10-14 12-18 15-20 17-21 19-22 21-25 23-27 25-29 26-31 28-33
1.56 NC <20 <20 <20 <20 21 26 32 36 40 44
Ak = .674 CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 THROW 12-16 14-19 17-21 18-22 20-24 22-26 24-29 26-31 28-33 29-35
2.25 NC <20 <20 <20 21 23 28 34 38 42 45
Ak = 914 CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 THROW 13-18 16-20 18-21 19-23 20-25 23-27 25-30 27-32 29-34 31-36
3.06 NC <20 <20 <20 22 23 30 36 40 44 49
Ak = 1.22 CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 THROW 14-18 17-20 18-22 20-24 21-25 24-28 26-31 28-33 30-36 32-38
4.00 NC <20 <20 20 23 24 31 37 41 45 50

6
CEILING DIFFUSER (CD)

CDSS-3 (THREE WAY)

Area Factor Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900
Velocity Pressure
Size (AK) .003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(in. w.g.)
(inch) Neck Area
Total Pressure
(sq.ft.) (in. w.g.)
.012 .019 .027 .036 .048 .074 .107 .146 .190 .240

Ak = .085 CFM 50 63 75 88 100 125 150 175 200 225


6x6 THROW 3-5 4-6 4-7 5-8 6-9 8-11 9-13 10-15 12-17 14-19
0.250 NC <20 <20 <20 <20 <20 <20 23 27 31 35
Ak = .177 CFM 110 140 170 195 225 280 335 395 450 505
9x9 THROW 4-7 5-8 6-9 7-11 8-12 10-15 13-18 15-21 17-22 19-23
0.562 NC <20 <20 <20 <20 <20 21 27 31 35 39
Ak = .306 CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 THROW 5-8 6-10 8-11 9-13 10-15 13-19 16-21 18-22 20-24 21-25
1.000 NC <20 <20 <20 <20 <20 23 30 34 38 42
Ak = .472 CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 THROW 6-9 8-11 9-13 11-15 12-17 16-20 18-22 20-24 21-26 22-27
1.56 NC <20 <20 <20 <20 21 26 32 36 40 44
Ak = .674 CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 THROW 7-11 9-13 11-15 13-18 14-19 18-22 20-24 21-25 23-27 24-29
2.25 NC <20 <20 <20 21 23 28 34 38 42 45
Ak = 914 CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 THROW 8-12 10-14 12-17 14-19 16-20 19-23 21-25 22-27 24-28 25-30
3.06 NC <20 <20 <20 22 23 30 36 40 44 49
Ak = 1.22 CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 THROW 9-13 11-16 13-18 15-20 17-21 19-23 21-25 23-27 25-29 26-31
4.00 NC <20 <20 20 23 24 31 37 41 45 50

CDSS-4 (FOUR WAY)


Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900
Area Factor
Size (AK) Velocity Pressure
.003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(in. w.g.)
(inch) Neck Area
(sq.ft.)
Total Pressure
.011 .017 .024 .032 .042 .066 .096 .130 .170 .245
(in. w.g.)
Ak = .085 CFM 50 63 75 88 100 125 150 175 200 225
6x6 THROW 2-4 3-6 4-7 5-8 6-9 7-11 8-12 10-14 11-16 13-18
0.250 NC <20 <20 <20 <20 <20 <20 23 27 31 35
Ak = .177 CFM 110 140 170 195 225 280 335 395 450 505
9x9 THROW 4-6 5-7 6-9 7-10 8-11 10-13 11-16 13-19 15-20 17-21
0.562 NC <20 <20 <20 <20 <20 21 27 31 35 39
Ak = .306 CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 THROW 5-7 6-9 7-11 8-12 10-14 12-17 14-20 17-21 18-23 20-24
1.000 NC <20 <20 <20 <20 <20 23 30 34 38 42
Ak = .472 CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 THROW 6-9 7-11 9-13 10-15 12-17 14-19 17-21 18-22 20-24 21-25
1.56 NC <20 <20 <20 <20 21 26 32 36 40 44
Ak = .674 CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 THROW 7-10 8-12 10-14 12-16 13-18 16-20 18-22 20-24 21-26 22-27
2.25 NC <20 <20 <20 21 23 28 34 38 42 45
Ak = 914 CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 THROW 7-11 9-13 11-16 13-18 15-19 18-22 20-24 21-25 23-27 24-29
3.06 NC <20 <20 <20 22 23 30 36 40 44 49
Ak = 1.22 CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 THROW 8-12 10-15 12-18 14-19 16-20 19-23 20-25 22-26 23-28 25-30
4.00 NC <20 <20 20 23 24 31 37 41 45 50

7
CEILING DIFFUSER (CD)

CDSR-1 (ONE WAY)


Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900

Size Neck Area Velocity Pressure .003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(in. w.g.)
(inch) (Sq. ft.)
Negative Static
.037 .058 .083 .112 .148 .230 .332 .450 .590 .752
Pressure (in. w.g.)
CFM 50 63 75 88 100 125 150 175 200 225
6x6 0.250
NC <20 <20 <20 <20 <20 <20 22 26 30 34
CFM 110 140 170 195 225 280 335 395 450 505
9x9 0.562
NC <20 <20 <20 <20 <20 20 26 30 34 38
CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 1.00
NC <20 <20 <20 <20 <20 22 29 33 37 41
CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 1.56
NC <20 <20 <20 <20 20 25 31 35 39 43
CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 2.25
NC <20 <20 <20 20 22 27 33 37 41 44
CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 3.06
NC <20 <20 <20 21 22 29 35 39 43 48
CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 4.00
NC <20 <20 <20 22 23 30 36 40 44 49

CDSR-2 (TWO WAY)


Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900
Velocity Pressure
Size Neck Area (in. w.g.) .003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(inch) (Sq. ft.)
Negative Static
.042 .066 .096 .130 .170 .265 .381 .518 .680 .852
Pressure (in. w.g.)
CFM 50 63 75 88 100 125 150 175 200 225
6x6 0.250
NC <20 <20 <20 <20 <20 <20 22 26 30 34
CFM 110 140 170 195 225 280 335 395 450 505
9x9 0.562
NC <20 <20 <20 <20 <20 20 26 30 34 38
CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 1.00
NC <20 <20 <20 <20 <20 22 29 33 37 41
CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 1.56
NC <20 <20 <20 <20 20 25 31 35 39 43
CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 2.25
NC <20 <20 <20 20 22 27 33 37 41 44
CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 3.06
NC <20 <20 <20 21 22 29 35 39 43 48
CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 4.00
NC <20 <20 <20 22 23 30 36 40 44 49

8
CEILING DIFFUSER (CD)

CDSR-3 (THREE WAY)


Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900
Velocity Pressure
Size Neck Area .003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(in. w.g.)
(inch) (Sq. ft.)
Negative Static
.038 .059 .085 .107 .154 .235 .336 .460 .600 .757
Pressure (in. w.g.)
CFM 50 63 75 88 100 125 150 175 200 225
6x6 0.250
NC <20 <20 <20 <20 <20 <20 22 26 30 34
CFM 110 140 170 195 225 280 335 395 450 505
9x9 0.562
NC <20 <20 <20 <20 <20 20 26 30 34 38
CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 1.00
NC <20 <20 <20 <20 <20 22 29 33 37 41
CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 1.56
NC <20 <20 <20 <20 20 25 31 35 39 43
CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 2.25
NC <20 <20 <20 20 22 27 33 37 41 44
CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 3.06
NC <20 <20 <20 21 22 29 35 39 43 48
CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 4.00
NC <20 <20 <20 22 23 30 36 40 44 49

CDSR-4 (FOUR WAY)


Neck Velocity (fpm) 200 250 390 350 400 500 600 700 800 900
Velocity Pressure
Size Neck Area (in. w.g.) .003 .004 .006 .008 .010 .016 .023 .031 .040 .051
(inch) (Sq. ft.)
Negative Static
.043 .067 .097 .132 .172 .269 .388 .525 .690 .864
Pressure (in. w.g.)
CFM 50 63 75 88 100 125 150 175 200 225
6x6 0.250
NC <20 <20 <20 <20 <20 <20 22 26 30 34
CFM 110 140 170 195 225 280 335 395 450 505
9x9 0.562
NC <20 <20 <20 <20 <20 20 26 30 34 38
CFM 200 250 300 350 400 500 600 700 800 900
12 x 12 1.00
NC <20 <20 <20 <20 <20 22 29 33 37 41
CFM 310 390 470 545 625 780 940 1090 1250 1405
15 x 15 1.56
NC <20 <20 <20 <20 20 25 31 35 39 43
CFM 450 560 675 785 900 1125 1350 1575 1800 2025
18 x 18 2.25
NC <20 <20 <20 20 22 27 33 37 41 44
CFM 610 765 920 1070 1225 1530 1835 2140 2450 2755
21 x 21 3.06
NC <20 <20 <20 21 22 29 35 39 43 48
CFM 800 1000 1200 1400 1600 2000 2400 2800 3200 3600
24 x 24 4.00
NC <20 <20 <20 22 23 30 36 40 44 49

9
CEILING DIFFUSER (CD)

CDRS-1V (ONE WAY)


Area Factor Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Size (AK) Velocity Pressure (in. w.g.) .003 .006 .010 .016 .023 .031 .040 .051
(inches) Neck Area Total Pressure (in. w.g.) .021 .046 .081 .130 .180 .250 .320 .390
(Sq.ft) Slide A B A B A B A B A B A B A B A B
Ak = .122 CFM TOTAL 75 110 150 190 225 265 300 337
CFM / SIDE 75 - 110 - 150 - 190 - 225 - 265 - 300 - 337 -
9x6 THROW / SIDE 10-14 - 12-17 - 14-20 - 16-23 - 17-25 - 18-26 - 20-28 - 21-30 -
0.375 NC <20 <20 <20 <20 25 29 33 37
Ak = .158 CFM TOTAL 100 150 200 250 300 350 400 450
CFM / SIDE 100 - 150 - 200 - 250 - 300 - 350 - 400 - 450 -
12 x 6 THROW / SIDE 10-15 - 12-17 - 14-20 - 16-23 - 17-25 - 18-26 - 20-28 - 21-30 -
0.500 NC <20 <20 <20 20 27 30 34 38
Ak = .232 CFM TOTAL 150 225 300 3275 450 525 600 675
CFM / SIDE 150 - 225 - 300 - 375 - 450 - 525 - 600 - 675 -
12 x 9 THROW / SIDE 13-19 - 15-21 - 17-24 -
19-
- 21-30 - 22-32 - 24-34 - 26-36 -
271
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = .195 CFM TOTAL 125 188 250 313 375 438 500 565
CFM / SIDE 125 - 188 - 250 - 313 - 375 - 438 - 500 - 565 -
15 x 6 THROW / SIDE 12-17 - 14-19 - 16-23 - 18-25 - 20-27 - 21-29 - 23-31 - 24-33 -
0.625 NC <20 <20 <20 21 27 31 35 39
Ak = .287 CFM TOTAL 188 281 375 469 563 656 750 845
CFM / SIDE 188 - 281 - 375 - 469 - 563 - 656 - 750 - 845 -
15 x 9 THROW / SIDE 14-19 - 16-23 - 18-26 - 21-30 - 22-32 - 24-34 - 25-37 - 27-39 -
0.938 NC <20 <20 <20 21 27 31 35 39
Ak = .380 CFM TOTAL 250 375 500 625 750 875 1000 1125
CFM / SIDE 250 - 375 - 500 - 625 - 750 - 875 - 1000 - 1125 -
15 x 12 THROW / SIDE 15-21 - 17-24 - 20-28 - 23-32 - 25-34 - 26-37 - 28-40 - 30-42 -
1.25 NC <20 <20 <20 25 31 35 39 43
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 150 - 225 - 300 - 375 - 450 - 525 - 600 - 675 -
18 x 6 THROW / SIDE 13-19 - 15-21 - 17-24 - 19-27 - 21-30 - 22-32 - 24-34 - 26-36 -
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = 343 CFM TOTAL 225 338 450 563 675 788 900 1012
CFM / SIDE 225 - 338 - 450 - 563 - 675 - 788 - 900 - 1012 -
18 x 9 THROW / SIDE 14-19 - 16-23 - 18-26 - 21-30 - 22-32 - 24-34 - 25-37 - 27-39 -
1.125 NC <20 <20 <20 24 30 34 38 42
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 300 - 450 - 600 - 750 - 900 - 1050 - 1200 - 1350 -
18 x 12 THROW / SIDE 14-20 - 17-24 - 20-28 - 23-32 - 25-34 - 26-37 - 28-40 - 30-42 -
0.875 NC <20 <20 <20 26 32 36 40 44
Ak .269 CFM TOTAL 175 263 350 438 525 613 700 787
CFM / SIDE 175 - 263 - 350 - 438 - 525 - 613 - 700 - 787 -
21 x 6 THROW / SIDE 13-19 - 15-21 - 17-24 - 19-27 - 21-30 - 22-32 - 24-34 - 26-36 -
0.875 NC <20 <20 <20 22 28 32 36 40
Ak = .398 CFM TOTAL 263 394 525 656 788 919 1050 1181
CFM / SIDE 263 - 394 - 525 - 656 - 788 - 919 - 1050 - 1181 -
21 x 9 THROW / SIDE 15-21 - 17-24 - 20-28 - 23-32 - 25-34 - 26-37 - 28-40 - 30-42 -
1.313 NC <20 <20 <20 24 30 34 38 42
Ak = .523 CFM TOTAL 350 525 700 875 1050 1125 1400 1575
CFM / SIDE 350 - 525 - 700 - 875 - 1050 - 1225 - 1400 - 1575 -
21 x 12 THROW / SIDE 15-22 - 18-26 - 21-30 - 24-34 - 26-37 - 28-40 - 30-42 - 32-45 -
1.75 NC <20 <20 <20 26 32 36 40 44
Ak = .306 CFM TOTAL 200 300 400 500 600 700 800 900
CFM / SIDE 200 - 300 - 400 - 500 - 600 - 700 - 800 - 900 -
24 x 6 THROW / SIDE 14-20 - 16-23 - 18-26 - 21-30 - 22-32 - 24-34 - 25-37 - 27-39 -
1.00 NC <20 <20 <20 23 29 33 37 41
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 300 - 450 - 600 - 750 - 900 - 1050 - 1200 - 1350 -
24 x 9 THROW / SIDE 14-20 - 17-24 - 20-28 - 23-32 - 25-34 - 26-37 - 28-40 - 30-42 -
1.50 NC <20 <20 <20 25 31 35 39 43
Ak = .601 CFM TOTAL 400 600 800 1000 1200 1400 1600 1800
CFM / SIDE 400 - 600 - 800 - 1000 - 1200 - 1400 - 1600 - 1800 -
24 x 12 THROW / SIDE 17-24 - 20-28 - 23-32 - 26-37 - 28-39 - 30-42 - 33-45 - 35-48 -
2.00 NC <20 <20 20 27 33 37 41 45

10
CEILING DIFFUSER (CD)

CDRS-2V (TWO WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Area Factor Velocity Pressure
.003 .006 .010 .016 .023 .031 .040 .051
Size (AK) (in. w.g.)
(inches) Neck Area Total Pressure
(Sq.ft) .016 .036 .064 .100 .140 .200 .260 .320
(in. w.g.)
Slide A B A B A B A B A B A B A B A B
Ak = .122 CFM TOTAL 75 113 150 188 225 263 300 338
CFM / SIDE 37 - 56 - 75 - 94 - 112 - 131 - 150 - 169 -
9x6
THROW / SIDE 8-11 - 10-13 - 11-15 - 13-17 - 14-18 - 15-20 - 16-21 - 17-23 -
0.375 NC <20 <20 <20 <20 25 29 33 37
Ak = .158 CFM TOTAL 100 150 200 250 300 350 400 450
CFM / SIDE 50 - 75 - 100 - 125 - 150 - 175 - 200 - 225 -
12 x 6
THROW / SIDE 9-12 - 10-14 - 11-16 - 13-18 - 14-20 - 15-21 - 16-23 - 17-24 -
0.500 NC <20 <20 <20 20 27 30 34 38
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 75 - 112 - 150 - 187 - 225 - 262 - 300 - 337 -
12 x 9
THROW / SIDE 10-14 - 12-17 - 14-20 - 16-23 - 17-25 - 18-26 - 20-28 - 21-30 -
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = .195 CFM TOTAL 125 188 250 313 375 438 500 563
CFM / SIDE 62 - 94 - 125 - 156 - 187 - 219 - 250 - 281 -
15 x 6
THROW / SIDE 9-14 - 11-16 - 13-18 - 15-21 - 16-22 - 17-24 - 18-25 - 20-27 -
0.625 NC <20 <20 <20 21 27 31 35 39
Ak = .287 CFM TOTAL 188 281 375 469 563 656 750 844
CFM / SIDE 94 - 140 - 187 - 235 - 281 - 328 - 375 - 422 -
15 x 9
THROW / SIDE 10 14 - 12-17 - 14-20 - 16-23 - 17-25 - 18-26 - 20-28 - 21-30 -
0.938 NC <20 <20 <20 23 29 33 37 41
Ak = .380 CFM TOTAL 250 375 500 625 750 875 1000 1125
CFM / SIDE 125 - 187 - 250 - 312 - 375 - 437 - 500 - 562 -
15 x 12
THROW / SIDE 12-16 - 14-19 - 16 22 - 18-25 - 20 27 - 21-29 - 23-31 - 24-33 -
1.25 NC <20 <20 <20 25 31 35 39 43
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 75 - 112 - 150 - 187 - 225 - 262 - 300 - 337 -
18 x 6
THROW / SIDE 9-14 - 12-17 - 14-20 - 16-23 - 17-25 - 18-26 - 20-28 - 21-30 -
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = 343 CFM TOTAL 225 338 450 563 675 788 900 1012
CFM / SIDE 112 - 169 - 225 - 281 - 337 - 394 - 450 - 506 -
18 x 9
THROW / SIDE 12-16 - 14-19 - 16-22 - 18 25 - 20-27 - 21-29 - 23 31 - 24-33 -
1.125 NC <20 <20 <20 24 30 34 38 42
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 150 - 225 - 300 - 375 - 450 - 525 - 600 - 6751 -
18 x 12
THROW / SIDE 12-18 - 15-21 - 17-24 - 19-27 - 21-30 - 22-32 - 24-34 - 26-36 -
0.875 NC <20 <20 <20 26 32 36 40 44
Ak .269 CFM TOTAL 175 263 350 438 525 613 700 787
CFM / SIDE 87 - 131 - 175 - 219 - 262 - 306 - 350 - 393 -
21 x 6
THROW / SIDE 10-14 - 12-17 - 14-20 - 16-23 - 17-25 - 18-26 - 20-28 - 21-30 -
0.875 NC <20 <20 <20 22 28 32 36 40
Ak = .398 CFM TOTAL 263 394 525 656 788 919 1050 1181
CFM / SIDE 131 - 197 - 262 - 328 - 394 - 459 - 525 - 590 -
21 x 9
THROW / SIDE 12-16 - 14-19 - 16-22 - 18-25 - 20-27 - 21-29 - 23-31 - 24-33 -
1.313 NC <20 <20 <20 24 30 34 38 42
Ak = .523 CFM TOTAL 350 525 700 875 1050 1225 1400 1575
CFM / SIDE 175 - 262 - 350 - 437 - 525 - 612 - 700 - 787 -
21 x 12
THROW / SIDE 13-18 - 15-21 - 17-24 - 19-27 - 21-30 - 22-32 - 24-34 - 26-36 -
1.75 NC <20 <20 <20 26 32 36 40 44
Ak = .306 CFM TOTAL 200 300 400 500 600 700 800 900
CFM / SIDE 100 - 150 - 200 - 250 - 300 - 350 - 400 - 450 -
24 x 6
THROW / SIDE 10-14 - 12-17 - 14-20 16-23 - 17-25 - 18-26 - 20-28 - 21-30 -
1.00 NC <20 <20 <20 23 29 33 37 41
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 150 225 3001 - 375 450 525 600 675 -
24 x 9
THROW / SIDE 13-18 15-21 17-24 19-27 21-30 22-32 24-34 26-36
1.50 NC <20 <20 <20 25 31 35 39 43
Ak = .601 CFM TOTAL 400 600 800 1000 1200 1400 1600 1800
CFM / SIDE 200 - 300 - 400 - 500 - 600 - 700 - 800 - 900 -
24 x 12
THROW / SIDE 14-20 - 16-23 - 18-26 - 21-30 - 22-32 - 24-34 - 25-37 - 27-39 -
2.00 NC <20 <20 20 27 33 37 41 45

11
CEILING DIFFUSER (CD)

CDRS-2C (TWO WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Area Factor Velocity Pressure
.003 .006 .010 .016 .023 .031 .040 .051
Size (AK) (in. w.g.)
(inches) Neck Area Total Pressure
.016 .036 .064 .100 .140 .200 .260 .319
(Sq.ft) (in. w.g.)
Slide A B A B A B A B A B A B A B A B
Ak = .122 CFM TOTAL 75 113 150 188 225 263 300 337
CFM / SIDE 50 25 75 38 100 50 125 63 150 75 175 88 200 100 225 112
9x6
THROW / SIDE 8-12 7-9 10-14 8-10 11-16 9-12 13-18 10-14 14-20 11-15 15-21 12-16 16-23 13-17 17-24 14-18
0.375 NC <20 <20 <20 20 25 29 33 37
Ak = .158 CFM TOTAL 100 150 200 250 300 350 400 450
CFM / SIDE 75 25 112 38 150 50 188, 62 225 75 263 87 300 100 338 112
12 x 6
THROW / SIDE 10-14 7-9 12-17 8-10 14-20 9-12 16-23 10-14 17-25 11-15 18-26 12-16 20-28 13-17 21-30 14-18
0.500 NC <20 <20 <20 20 27 30 34 38
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 94 56 141 84 188 112 235 140 282 168 329 196 375 225 423 252
12 x 9
THROW / SIDE 10-14 8-11 12-17 10-13 14-20 11-15 16-23 13-17 17-25 14-18 18-26 15-20 20-28 16-21 21-30 17-23
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = .195 CFM TOTAL 125 188 250 313 375 438 500 563
CFM / SIDE 100 25 150 37 200 50 250 62 300 75 350 87 400 100 450 112
15 x 6
THROW / SIDE 10-14 7-9 12-17 8-10 14-20 9-12 16-23 10-14 17-25 11-15 18-26 12-16 20-28 13-17 21-30 14-18
0.625 NC <20 <20 <20 21 27 31 35 39
Ak = .287 CFM TOTAL 188 281 375 469 563 565 750 845
CFM / SIDE 131 56 197 84 263 112 329 141 394 169 459 197 525 225 592 253
15 x 9
THROW / SIDE 12-16 8-11 14-19 10-13 16-22 11-15 18-25 13-17 20-27 14-18 21-28 15-20 23-31 16-21 24-33 17-23
0.938 NC <20 <20 <20 23 29 33 37 41
Ak = .380 CFM TOTAL 250 375 500 625 750 875 1000 1125
CFM / SIDE 150 100 225 150 300 200 375 250 450 300 525 350 600 400 675 450
15 x 12
THROW / SIDE 13,18 9-14 15-21 11-16 17-24 13-18 19-27 15-21 21-30 16-22 22-32 17-24 24-34 18-25 26-36 20-27
1.25 NC <20 <20 <20 25 31 35 39 43
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 124 26 186 39 248 52 310 65 372 78 434 91 496 104 558 117
18 x 6
THROW / SIDE 12-16 7-9 14-19 8-10 16-22 9-12 18-25 10-14 20-27 11-15 21-29 12-16 23-31 13-17 24-33 14-18
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = 343 CFM TOTAL 225 338 450 563 675 788 900 1012
CFM / SIDE 169 56 254 84 338 112 422 141 506 169 591 197 675 225 759 253
18 x 9
THROW / SIDE 13-18 9-11 15-21 10-13 17-24 11-15 19-27 13-17 21-30 14-18 22-32 15-20 24-34 16-21 26-36 17-23
1.125 NC <20 <20 <20 24 30 34 38 42
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 200 100 300 150 400 200 500 250 600 300 700 350 800 400 900 450
18 x 12
THROW / SIDE 14-20 9-14 16-23 11-16 18-26 13-18 21-30 15-21 22-32 16-22 24-34 17-24 25-37 18-25 27-39 20-27
0.875 NC <20 <20 <20 26 32 36 40 44
Ak .269 CFM TOTAL 175 263 350 438 525 613 700 787
CFM / SIDE 150 25 225 38 300 50 375 63 450 752 525 87 600 100 675 112
21 x 6
THROW / SIDE 14-18 7-9 15-21 8-10 17-24 9-12 19-27 10-14 21-30 11-15 22-32 12-16 24-34 13-17 26-36 14-18
0.875 NC <20 <20 <20 22 28 32 36 40
Ak = .398 CFM TOTAL 263 394 525 656 788 919 1050 1181
CFM / SIDE 206 57 308 85 412 113 514 142 618 170 720 199 825 225 927 253
21 x 9
THROW / SIDE 14-20 9-11 16-23 10-13 18-26 11-15 21-0 13-17 22-32 14-18 24-34 15-20 25-37 16-21 27-39 17-23
1.313 NC <20 <20 <20 24 30 34 38 42
Ak = .523 CFM TOTAL 350 525 700 875 1050 1225 1400 1575
CFM / SIDE 250 100 375 150 500 200 625 250 750 300 875 350 1000 400 1125 450
21 x 12
THROW / SIDE 14-20 9-14 17-24 11-16 20-28 13-18 23-32 15-21 25-34 16-22 26-37 17-24 28-40 18-25 30-42 20-27
1.75 NC <20 <20 <20 26 32 36 40 44
Ak = .306 CFM TOTAL 200 300 400 500 600 700 800 900
CFM / SIDE 175 25 263 37 350 50 438 62 525 75 613 87 700 100 788 112
24 x 6
THROW / SIDE 13-19 7-9 15-21 8-10 17-24 9-12 19-27 10-14 21-30 11-15 22-32 12-16 24-34 13-17 26-36 14-18
1.00 NC <20 <20 <20 23 29 33 37 41
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 244 56 366 84 488 112 609 141 731 169 853 197 975 225 1097 253
24 x 9
THROW / SIDE 14-20 9-11 17-24 10-13 20-28 11-15 23-32 13-17 25-34 14-18 26-37 15-20 28-40 16-21 30-42 17-23
1.50 NC <20 <20 <20 25 31 35 39 43
Ak = .601 CFM TOTAL 400 600 800 1000 1200 1400 1600 1800
CFM / SIDE 300 100 450 150 600 200 750 250 900 300 1050 350 1200 400 1350 450
24 x 12
THROW / SIDE 14-20 9-14 17-24 11-16 20-28 13-18 23-32 15-21 25-34 16-22 26-37 17-24 28-40 18-25 30-42 20-27
2.00 NC <20 <20 20 27 33 37 41 45

12
CEILING DIFFUSER (CD)

CDRS-3 (THREE WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Area Factor Velocity Pressure .003 .006 .010 .016 .023 .031 .040 .051
Size (AK) (in. w.g.)
(inches) Neck Area Total Pressure
(Sq.ft) .013 .029 .052 .080 .120 .160 .210 .255
(in. w.g.)
Slide A B A B A B A B A B A B A B A B
Ak = .122 CFM TOTAL 75 113 150 188 225 263 300 337
CFM / SIDE 31 13 47 19 62 26 78 32 93 39 109 45 124 52 140 59
9x6
THROW / SIDE 7-9 4-6 8-11 5-7 9-13 6-8 10-15 7-9 11-16 7-10 12-17 8-11 13-18 8-11 14-20 9-12
0.375 NC <20 <20 <20 <20 25 29 33 37
Ak = .158 CFM TOTAL 100 150 200 250 300 350 400 450
CFM / SIDE 43 14 65 20 86 28 108 34 129 42 151 48 172 56 194 52
12 x 6
THROW / SIDE 9-12 4-6 10-14 5-7 11-16 6-8 13-18 7-9 14-20 7-10 15-21 8-11 16-23 8-11 17-24 9-12
0.500 NC <20 <20 <20 20 27 30 34 38
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 61 28 921 41 122 56 153 69 183 84 213 98 244 112 275 125
12 x 9
THROW / SIDE 9-14 5-8 11-16 6-9 13-18 7-10 15-21 8-11 16-22 9-12 17-24 9-13 18-26 10-14 20-27 11-15
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = .195 CFM TOTAL 125 188 250 313 375 438 500 563
CFM / SIDE 56 13 84 20 112 26 140 33 169 37 197 44 225 50 253 58
15 x 6
THROW / SIDE 8-13 4-6 10-15 5-7 12-17 6-8 14-19 7-9 15-21 7-10 16-22 8-11 17-24 8-11 18-26 9-12
0.625 NC <20 <20 <20 21 27 31 35 39
Ak = .287 CFM TOTAL 188 281 375 469 563 656 750 845
CFM / SIDE 80 28 120 42 159 56 200 70 240 84 279 98 319 112 359 126
15 x 9
THROW / SIDE 10-14 5-8 12-17 6-9 14-20 7-10 16-23 8-11 17-25 9-12 18-26. 9-13 20-28 10-14 21-30 11-16
0.938 NC <20 <20 <20 23 29 33 37 41
Ak = .380 CFM TOTAL 250 375 500 625 750 875 1000 1125
CFM / SIDE 100 50 150 75 200 100 250 125 300 150 350 175 400 200 450 225
15 x 12
THROW / SIDE 10-14 7-9 12-17 8-10 14-20 9-12 16-23 10-14 17-25 11-15 18-26 12-16 20-28 13-17 21-30 14-18
1.25 NC <20 <20 <20 25 31 35 39 43
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 69 12 103 18 138 24 172 31 2071 36 241 43 275 50 310 55
18 x 6
THROW / SIDE 9-14 4-6 11-16 5-7 13-18 6-8 15-21 7-9 16-22 7-10 17-24 8-11 18-25 8-11 20-27 9-12
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = 343 CFM TOTAL 225 338 450 563 675 788 900 1012
CFM / SIDE 98 29 147 43 196 58 246 70 294 87 345 98 394 112 441 130
18 x 9
THROW / SIDE 10-14 5-7 12-17 6-9 14-20 7-10 16-23 8-11 17-25 9-12 18-26 9-13 20-28 10-14 21-30 11-15
1.125 NC <20 <20 <20 24 30 34 38 42
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 125 50 187 75 250 100 312 125 375 150 437 175 500 200 562 225
18 x 12
THROW / SIDE 12-16 7-9 14-19 8-10 16-22 9-12 18-25 10-14 20-27 11-15 21-29 12-16 23-31 13-17 24-33 14-16
0.875 NC <20 <20 <20 26 32 36 40 44
Ak .269 CFM TOTAL 175 263 350 438 525 613 700 787
CFM / SIDE 81 13 122 19 162 26 203 32 244 37 284 45 324 52 364 58
21 x 6
THROW / SIDE 10-14 4-6 12-17 5-7 14-20 6-8 16-23 7-9 17-25 7-10 18-26 8-11 20-28 8-11 21-30 9-12
0.875 NC <20 <20 <20 22 28 32 36 40
Ak = .398 CFM TOTAL 263 394 525 656 788 919 1050 1181
CFM / SIDE 117 29 175 43 234 57 292 72 351 86 409 101 467 115 527 126
21 x 9
THROW / SIDE 12-16 5-8 14-19 6-9 16-22 7-10 18-25 8-11 20-27 9-12 21-29 9-13 23-31 10-14 24-33 11-15
1.313 NC <20 <20 <20 24 30 34 38 42
Ak = .523 CFM TOTAL 350 525 700 875 1050 1225 1400 1575
CFM / SIDE 150 50 225 75 300 100 375 125 450 150 525 75 600 200 670 225
21 x 12
THROW / SIDE 13-18 7-9 15-21 8-10 17-24 9-12 19-27 10-14 21-30 11-15 22-32 12-16 24-34 13-17 26-36 14-18
1.75 NC <20 <20 <20 26 32 36 40 44
Ak = .306 CFM TOTAL 200 300 400 500 600 700 800 900
CFM / SIDE 93 14 141 18 187 25 234 31 279 42 325 50 372 56 422 56
24 x 6
THROW / SIDE 10-14 4-6 12-17 5-7 14-20 6-8 16-23 7-9 17-25 7-10 18-26 8-11 20-28 8-11 21-30 9-12
1.00 NC <20 <20 <20 23 29 33 37 41
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 136 28 204 42 272 56 340 70 408 84 476 98 544 112 612 126
24 x 9
THROW / SIDE 12-16 5-7 14-19 6-9 16-22 7-10 18-25 8-11 20-27 9-12 21-29 9-13 23-31 10-14 24-33 11-15
1.50 NC <20 <20 <20 25 31 35 39 43
Ak = .601 CFM TOTAL 400 600 800 1000 1200 1400 1600 1800
CFM / SIDE 175 50 262 75 350 100 437 125 525 150 612 175 700 200 787 225
24 x 12
THROW / SIDE 13-18 7-9 15-21 8-10 17-24 9-12 19-24 10-14 21-30 11-15 22-32 12-16 24-34 13-17 26-36 14-18
2.00 NC <20 <20 20 27 33 37 41 45

13
CEILING DIFFUSER (CD)

CDRS-4 (FOUR WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Area Factor
Size (AK) Velocity Pressure (in. w.g.) .003 .006 .010 .016 .023 .031 .040 .051
(inches) Neck Area Total Pressure (in. w.g.) .015 .033 .058 .091 .130 .180 .230 .310
(Sq.ft)
Slide A B A B A B A B A B A B A B A B
Ak = .122 CFM TOTAL 75 113 150 188 225 263 300 337
CFM / SIDE 25 12 38 18 50 25 63 31 75 37 87 44 100 50 112 56
9x6
THROW / SIDE 7-9 4-6 8-10 5-7 9-12 6-8 10-14 7-9 11-15 7-10 12-16 8-11 13-17 8-11 14-18 9-12
0.375 NC <20 <20 <20 <20 25 29 33 37
Ak = .158 CFM TOTAL 100 150 200 250 300 350 400 450
CFM / SIDE 38 12 57 18 76 24 94 31 113 37 133 42 152 48 171 54
12 x 6
THROW / SIDE 9-11 4-6 10-13 5-7 11-15 7-8 13-17 7-9 14-18 7-10 15-20 8-11 16-21 8-11 17-23 8-12
0.500 NC <20 <20 <20 20 27 30 34 38
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 47 28 70 42 94 56 117 70 141 84 164 98 138 112 211 126
12 x 9
THROW / SIDE 8-10 5-8 9-12 6-9 10-14 7-10 11-16 8-11 12-17 9-12 13-18 9-13 14-20 10-14 15-21 11-15
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = .195 CFM TOTAL 125 188 250 313 375 438 500 563
CFM / SIDE 50 12 75 18 100 25 125 31 150 37 175 44 200 50 225 56
15 x 6
THROW / SIDE 9-12 4-6 10-14 5-7 11-16 6-8 13-18 7-9 14-20 7-10 15-21 8-11 16-23 9-11 17-24 9-12
0.625 NC <20 <20 <20 21 27 31 35 39
Ak = .287 CFM TOTAL 188 281 375 469 563 656 750 845
CFM / SIDE 66 28 99 42 132 56 165 70 198 84 230 98 263 112 296 126
15 x 9
THROW / SIDE 9-14 5-8 11-16 6-9 13-18 7-10 15-21 8-11 16-22 9-12 17-24 9-13 18-25 10-14 20-27 11-15
0.938 NC <20 <20 <20 23 29 33 37 41
Ak = .380 CFM TOTAL 250 375 500 625 750 875 1000 1125
CFM / SIDE 75 50 112 75 150 100 187 125 225 150 262 175 300 200 337 225
15 x 12
THROW / SIDE 9-12 7-8 10-14 8-10 11-16 9-12 13-18 10-14 14-20 11-15 15-21 12-16 16-23 13-17 17-24 14-18
1.25 NC <20 <20 <20 25 31 35 39 43
Ak = .232 CFM TOTAL 150 225 300 375 450 525 600 675
CFM / SIDE 63 12 94 18 125 25 158 31 188 37 220 42 250 50 283 54
18 x 6
THROW / SIDE 9-14 4-6 11-16 5-7 13-18 6-8 15-21 7-9 18-22 7-10 17-24 8-11 18-25 8-11 20-27 9-12
0.750 NC <20 <20 <20 22 28 32 36 40
Ak = 343 CFM TOTAL 225 338 450 563 675 788 900 1012
CFM / SIDE 85 28 126 42 169 56 2111 70 254 84 296 98 338 112 380 126
18 x 9
THROW / SIDE 10-14 5-8 12-17 6-9 14-20 7-10 16-231 8-11 17-25 9-12 18-26 9-13 20-28 10-14 21-30 11-15
1.125 NC <20 <20 <20 24 30 34 38 42
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 100 50 150 75 200 100 250 125 300 150 350 175 400 200 450 225
18 x 12
THROW / SIDE 10-14 7-8 12-17 8-10 14-20 9-12 16-23 10-14 17-25 11-15 18-26 12-16 20-28 13-17 21-30 14-18
0.875 NC <20 <20 <20 26 32 36 40 44
Ak .269 CFM TOTAL 175 263 350 438 525 613 700 787
CFM / SIDE 75 12 113 18 150 25 188 31 225 37 262 44 300 50 337 56
21 x 6
THROW / SIDE 10-14 4-6 12-17 5-7 14-20 6-8 16-23 7-9 17-25 7-10 18-26 8-11 20-28 8-11 21-30 9-12
0.875 NC <20 <20 <20 22 28 32 36 42
Ak = .398 CFM TOTAL 263 394 525 656 788 919 1050 1181
CFM / SIDE 103 28 154 42 206 56 258 70 309 84 360 98 413 112 484 126
21 x 9
THROW / SIDE 12-16 5-8 14-19 6-9 16-22 7-10 18-25 8-11 20-27 8-12 21-29 9-13 23-31 10-14 24-33 11-15
1.313 NC <20 <20 <20 24 30 34 38 42
Ak = .523 CFM TOTAL 350 525 700 875 1050 1225 1400 1575
CFM / SIDE 125 50 187 75 250 100 312 125 375 150 437 175 500 200 562 225
21 x 12
THROW / SIDE 12-16 7-8 14-19 8-10 16-22 9-12 18-25 10-14 20-27 11-15 21-29 12-16 22-31 13-17 24-33 14-18
1.75 NC <20 <20 <20 26 32 36 40 44
Ak = .306 CFM TOTAL 200 300 400 500 600 700 800 900
CFM / SIDE 87 12 131 18 175 25 219 31 262 37 306 44 350 50 394 56
24 x 6
THROW / SIDE 10-14 4-6 12-17 5-7 14-20 6-8 16-23 7-9 17-25 7-10 18-26 8-11 20-28 8-11 21-30 9-12
1.00 NC <20 <20 <20 23 29 33 37 41
Ak = .453 CFM TOTAL 300 450 600 750 900 1050 1200 1350
CFM / SIDE 122 28 183 42 244 56 305 70 366 84 427 98 488 112 549 126
24 x 9
THROW / SIDE 12-16 5-8 14-19 6-9 16-22 7-10 18-25 8-11 20-27 9-12 21-29 9-13 23-31 10-14 24-33 11-15
1.50 NC <20 <20 <20 25 31 35 39 43
Ak = .601 CFM TOTAL 400 600 800 1000 1200 1400 1600 1800
CFM / SIDE 150 50 225 75 300 100 375 125 450 150 525 175 600 200 875 225
24 x 12
THROW / SIDE 13-18 7-9 15-21 8-10 17-24 9-12 18-27 10-14 21-31 11-15 22-32 12-16 24-34 13-17 23-36 14-18
2.00 NC <20 <20 <20 27 33 37 41 45

14
CEILING DIFFUSER (CD)

CDRR-1V (ONE WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Neck Ar- Velocity Pressure (in.
Size .003 .004 .006 .016 .023 .031 .040 .051
ea w.g.)
(inch)
(Sq. ft.) Negative Static Pressure
.051 .113 .119 320 .444 .617 .789 .962
(in. w.g.)
CFM 75 113 150 188 225 263 300 337
9x6 0.375
NC <20 <20 <20 <20 23 27 31 36
CFM 100 150 200 250 300 350 400 450
12 x 6 0.500
NC <20 <20 <20 <20 25 28 32 37
CFM 150 225 300 375 450 525 600 675
12 x 9 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 125 188 250 313 375 438 500 563
15 x 6 0.625
NC <20 <20 <20 <20 25 29 33 38
CFM 188 281 375 469 563 656 750 845
15 x 9 0.938
NC <20 <20 <20 21 27 31 35 40
CFM 250 375 500 625 750 875 1000 1125
15 x 12 1.25
NC <20 <20 <20 23 29 33 37 42
CFM 150 225 300 375 450 525 600 675
18 x 6 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 225 338 450 563 675 788 900 1012
18 x 9 1.125
NC <20 <20 <20 22 28 32 36 41
CFM 300 450 600 750 900 1050 1200 1350
18 x 12 1.50
NC <20 <20 <20 24 30 34 38 43
CFM 175 263 350 438 525 613 700 787
21 x 6 0.875
NC <20 <20 <20 20 26 30 34 39
CFM 263 394 525 656 788 919 1050 1181
21 x 9 1.31
NC <20 <20 <20 22 28 32 36 41
CFM 350 525 700 875 1050 1225 1400 1575
21 x 12 1.75
NC <20 <20 <20 24 30 34 38 43
CFM 200 300 400 500 600 700 800 900
24 x 6 1.00
NC <20 <20 <20 21 27 31 35 40
CFM 300 450 600 750 900 1050 1200 1350
24 x 9 1.50
NC <20 <20 <20 23 29 33 37 42
CFM 400 600 800 1000 1200 1400 1600 1800
24 x 12 2.00
NC <20 <20 <20 25 31 35 39 44

15
CEILING DIFFUSER (CD)

CDRR-2V (TWO WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Neck Ar- Velocity Pressure (in.
Size .003 .004 .006 .016 .023 .031 .040 .051
ea w.g.)
(inch)
(Sq. ft.) Negative Static Pressure
.048 .108 .192 .300 .420 .600 .780 .960
(in. w.g.)
CFM 75 113 150 188 225 263 300 337
9x6 0.375
NC <20 <20 <20 <20 23 27 31 36
CFM 100 150 200 250 300 350 400 450
12 x 6 0.500
NC <20 <20 <20 <20 25 28 32 37
CFM 150 225 300 375 450 525 600 675
12 x 9 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 125 188 250 313 375 438 500 563
15 x 6 0.625
NC <20 <20 <20 <20 25 29 33 38
CFM 188 281 375 469 563 656 750 845
15 x 9 0.938
NC <20 <20 <20 21 27 31 35 40
CFM 250 375 500 625 750 875 1000 1125
15 x 12 1.25
NC <20 <20 <20 23 29 33 37 42
CFM 150 225 300 375 450 525 600 675
18 x 6 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 225 338 450 563 675 788 900 1012
18 x 9 1.125
NC <20 <20 <20 22 28 32 36 41
CFM 300 450 600 750 900 1050 1200 1350
18 x 12 1.50
NC <20 <20 <20 24 30 34 38 43
CFM 175 263 350 438 525 613 700 787
21 x 6 0.875
NC <20 <20 <20 20 26 30 34 39
CFM 263 394 525 656 788 919 1050 1181
21 x 9 1.31
NC <20 <20 <20 22 28 32 36 41
CFM 350 525 700 875 1050 1225 1400 1575
21 x 12 1.75
NC <20 <20 <20 24 30 34 38 43
CFM 200 300 400 500 600 700 800 900
24 x 6 1.00
NC <20 <20 <20 21 27 31 35 40
CFM 300 450 600 750 900 1050 1200 1350
24 x 9 1.50
NC <20 <20 <20 23 29 33 37 42
CFM 400 600 800 1000 1200 1400 1600 1800
24 x 12 2.00
NC <20 <20 <20 25 31 35 39 44

16
CEILING DIFFUSER (CD)

CDRR-3 (THREE WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Neck Ar- Velocity Pressure (in.
Size .003 .004 .006 .016 .023 .031 .040 .051
ea w.g.)
(inch)
(Sq. ft.) Negative Static Pressure
.041 .092 .165 .253 .380 .507 .665 .808
(in. w.g.)
CFM 75 113 150 188 225 263 300 337
9x6 0.375
NC <20 <20 <20 <20 23 27 31 36
CFM 100 150 200 250 300 350 400 450
12 x 6 0.500
NC <20 <20 <20 <20 25 28 32 37
CFM 150 225 300 375 450 525 600 675
12 x 9 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 125 188 250 313 375 438 500 563
15 x 6 0.625
NC <20 <20 <20 <20 25 29 33 38
CFM 188 281 375 469 563 656 750 845
15 x 9 0.938
NC <20 <20 <20 21 27 31 35 40
CFM 250 375 500 625 750 875 1000 1125
15 x 12 1.25
NC <20 <20 <20 23 29 33 37 42
CFM 150 225 300 375 450 525 600 675
18 x 6 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 225 338 450 563 675 788 900 1012
18 x 9 1.125
NC <20 <20 <20 22 28 32 36 41
CFM 300 450 600 750 900 1050 1200 1350
18 x 12 1.50
NC <20 <20 <20 24 30 34 38 43
CFM 175 263 350 438 525 613 700 787
21 x 6 0.875
NC <20 <20 <20 20 26 30 34 39
CFM 263 394 525 656 788 919 1050 1181
21 x 9 1.31
NC <20 <20 <20 22 28 32 36 41
CFM 350 525 700 875 1050 1225 1400 1575
21 x 12 1.75
NC <20 <20 <20 24 30 34 38 43
CFM 200 300 400 500 600 700 800 900
24 x 6 1.00
NC <20 <20 <20 21 27 31 35 40
CFM 300 450 600 750 900 1050 1200 1350
24 x 9 1.50
NC <20 <20 <20 23 29 33 37 42
CFM 400 600 800 1000 1200 1400 1600 1800
24 x 12 2.00
NC <20 <20 <20 25 31 35 39 44

17
CEILING DIFFUSER (CD)

CDRR-4 (FOUR WAY)


Neck Velocity (fpm) 200 300 400 500 600 700 800 900
Neck Ar- Velocity Pressure (in.
Size .003 .004 .006 .016 .023 .031 .040 .051
ea w.g.)
(inch)
(Sq. ft.) Negative Static Pressure
.048 .105 .186 .292 .417 .578 .738 .995
(in. w.g.)
CFM 75 113 150 188 225 263 300 337
9x6 0.375
NC <20 <20 <20 <20 23 27 31 36
CFM 100 150 200 250 300 350 400 450
12 x 6 0.500
NC <20 <20 <20 <20 25 28 32 37
CFM 150 225 300 375 450 525 600 675
12 x 9 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 125 188 250 313 375 438 500 563
15 x 6 0.625
NC <20 <20 <20 <20 25 29 33 38
CFM 188 281 375 469 563 656 750 845
15 x 9 0.938
NC <20 <20 <20 21 27 31 35 40
CFM 250 375 500 625 750 875 1000 1125
15 x 12 1.25
NC <20 <20 <20 23 29 33 37 42
CFM 150 225 300 375 450 525 600 675
18 x 6 0.750
NC <20 <20 <20 20 26 30 34 39
CFM 225 338 450 563 675 788 900 1012
18 x 9 1.125
NC <20 <20 <20 22 28 32 36 41
CFM 300 450 600 750 900 1050 1200 1350
18 x 12 1.50
NC <20 <20 <20 24 30 34 38 43
CFM 175 263 350 438 525 613 700 787
21 x 6 0.875
NC <20 <20 <20 20 26 30 34 39
CFM 263 394 525 656 788 919 1050 1180
21 x 9 1.31
NC <20 <20 <20 22 28 32 36 41
CFM 350 525 700 875 1050 1225 1400 1575
21 x 12 1.75
NC <20 <20 <20 24 30 34 38 43
CFM 200 300 400 500 600 700 800 900
24 x 6 1.00
NC <20 <20 <20 21 27 31 35 40
CFM 300 450 600 750 900 1050 1200 1350
24 x 9 1.50
NC <20 <20 <20 23 29 33 37 42
CFM 400 600 800 1000 1200 1400 1600 1800
24 x 12 2.00
NC <20 <20 <20 25 31 35 39 44

18
CEILING DIFFUSER (CD)

RABIE perforated ceiling diffusers are with fully adjustable air pattern and with Opposed
Blade Damper detachable front perforated panel enables for easy access to core and
damper.
The throw pattern can be deflected in ( 1,2,3 and 4 ) directions.
Frame and blades are made of extruded aluminum alloy ( 6063-T6 ), polyester powder
coated ( RAL 9016 or 9010 ), other colors are available on request.
Diffuser face made of perforated sheet with 13/64” diameter performable to produce 50%
free area.
Galvanized steel neck adapter square to round can be provided upon request.

19
CEILING DIFFUSER (CD)

Difference between Neck and Face


FACE = NECK + 140mm

RABIE return perforated ceiling diffuser consists of perforated sheet face and extruded
aluminum frame.
The detachable front perforated face plate is made of perforated sheet with 13/64” diameter
performable to produce 50% free area, and hinged at one side.
Frame is made of extruded aluminum alloy ( 6063-T6 ), polyester powder coated (RAL 9016
or 9010), other colors are available on request.

20
CEILING DIFFUSER (CD)

Neck Size Neck Area Neck Velocity, FPM 300 400 500 600 700 800 1000 1200 1400
(Inches) (Sq.ft.) Velocity Pressure, in. W.G. .006 .010 .016 .023 .031 .040 .063 .090 .123
Total Pressure, in. W.G. .013 .023 .037 .053 .072 .094 .147 .211 .287
Flow Rate, CFM 74 98 123 148 173 200 250 300 350
NC <20 <20 <20 24 27 28 36 42 47
6X6 0.25 Throw, 4 - way 1-1 1-2 1-3 1-4 1-5 2-6 3-8 4-9 5-11
Feet 3 - way 1-3 1-5 2-6 3-8 4-9 5-10 6-13 8-16 9-17
2 - way 1-4 2-7 3-9 4-10 6-12 7-14 9-18 10-19 12-21
1 - way 1-6 2-8 4-11 6-13 7-15 8-17 11-20 13-22 15-24
Total Pressure, in. W.G. .018 .031 .049 .071 .096 .126 .196 .283 .385
Flow Rate, CFM 132 176 221 265 309 355 445 532 621
NC <20 <20 24 26 32 35 43 49 >50
8X8 0.44 Throw, 4 - way 1-2 1-4 1-6 2-7 3-8 4-9 6-12 7-14 8-17
Feet 3 - way 1-5 2-8 4-10 5-12 7-14 8-16 10-20 12-24 14-26
2 - way 2-8 4-10 6-13 8-16 9-19 10-21 13-26 16-29 19-31
1 - way 3-9 5-13 8-16 9-19 11-23 13-26 16-30 19-33 23-35
Total Pressure, in. W.G. .022 .039 .061 .088 .119 .156 .243 .350 .477
Flow Rate, CFM 209 276 346 415 484 556 693 831 972
NC <20 23 26 30 34 41 47 >50 >50
10 X 10 0.69 Throw, 4 - way 1-4 2-6 3-8 4-10 5-11 6-13 8-16 10-20 11-23
Feet 3 - way 2-8 4-11 6-13 8-16 9-19 11-22 13-27 16-32 19-35
2 - way 3-11 6-14 9-18 11-22 13-26 14-29 18-36 22-39 26-43
1 - way 5-13 9-18 11-22 13-27 16-32 18-36 22-41 27-45 32-49
Total Pressure, in. W.G. .026 .047 .073 .105 .144 .188 .293 .422 .574
Flow Rate, CFM 301 401 501 601 701 801 1001 1202 1403
NC <20 26 31 35 40 42 >50 >50 >50
12 X 12 1.00 Throw, 4 - way 1-6 3-8 4-11 6-13 7-15 8-17 11-22 13-26 15-30
Feet 3 - way 3-10 6-14 9-18 10-21 12-25 14-28 18-36 21-42 25-45
2 - way 5-14 9-19 12-24 14-29 17-34 19-39 24-46 29-51 34-55
1 - way 8-17 11-23 14-29 17-35 20-41 23-47 29-53 35-58 41-63
Total Pressure, in. W.G. .030 .055 .085 .122 .169 .220 .343 .494 .671
Flow Rate, CFM 409 543 681 815 951 1089 1361 1633 1905
NC <20 28 33 35 42 47 >50 >50 >50
14 X 14 1.36 Throw, 4 - way 1-8 4-10 5-13 8-16 9-19 10-22 14-28 16-32 19-37
Feet 3 - way 4-12 8-17 12-23 13-26 15-31 17-34 23-45 26-52 31-55
2 - way 7-17 12-24 15-30 17-36 22-42 24-49 30-56 36-62 42-67
1 - way 11-21 14-28 17-36 21-43 24-50 28-58 36-65 44-67 50-77
Total Pressure, in. W.G. .034 .063 .097 .139 .194 .252 .393 .566 .768
Flow Rate, CFM 534 712 890 1068 1246 1424 1780 2136 2492
NC 22 29 34 39 44 >50 >50 >50 >50
16 X 16 1.78 Throw, 4 - way 1-10 5-12 6-15 10-19 11-23 12-27 17-34 19-38 23-43
Feet 3 - way 5-14 10-20 14-28 16-31 18-37 20-40 28-54 31-62 37-65
2 - way 9-20 15-29 18-36 20-43 27-50 29-59 36-66 43-73 50-79
1 - way 14-25 17-33 20-43 25-51 28-59 33-69 43-77 53-84 56-94
Total Pressure, in. W.G. .036 .071 .109 .156 .209 .284 .443 .638 .865
Flow Rate, CFM 675 900 1125 1350 1575 1800 2250 2700 3150
18 X 18 NC 23 31 36 42 >50 >50 >50 >50 >50
2.25 Throw, 4 - way 1-12 6-14 7-17 12-22 13-27 14-32 20-40 22-44 27-50
w/o adaptor Feet 3 - way 6-16 12-23 16-32 18-36 21-43 23-46 33-63 36-72 43-75
2 - way 11-23 18-34 21-42 23-50 32-58 34-69 42-77 50-84 58-91
1 - way 17-29 20-38 23-50 29-59 32-68 38-80 50-89 62-97 68-108
Negative SP, in. W.G. .024 .043 .068 .098 .133 .174 .271 .391 .532
Return
2.25 Flow Rate, CFM 1008 1344 1680 2016 2352 2688 3360 4032 4704
18×18
NC <20 <20 <20 <20 22 26 34 40 46

• Throw values are given for Terminal Velocities of 100 and 50 fpm.
• NC values are based on a room absorption of 10 dB, re 10¯¹² watts.

21
CEILING DIFFUSER (CD)

Neck Size Neck Area Neck Velocity, FPM 300 400 500 600 700 800 1000 1200 1400
(Inches) (Sq.ft.) Velocity Pressure, in. W.G. .006 .010 .016 .023 .031 .040 .063 .090 .123
Total Pressure, in. W.G. .012 .021 .033 .047 .064 .084 .131 .189 .257
Flow Rate, CFM 56 77 99 116 136 155 197 235 274
NC <20 <20 <20 22 23 26 33 40 45
6ø 0.196 Throw, 4 - way 1-1 1-1 1-3 1-4 1-4 1-5 3-6 4-8 4-9
Feet 3 - way 1-2 1-4 1-5 2-6 3-7 4-8 5-11 6-13 7-14
2 - way 1-3 1-6 2-7 3-9 4-10 6-12 7-15 9-16 10-18
1 - way 1-4 2-7 3-9 4-11 6-13 7-14 9-17 11-19 13-20
Total Pressure, in. W.G. .015 .027 .043 .062 .084 .110 .171 .247 .336
Flow Rate, CFM 103 140 173 208 245 279 350 417 489
NC <20 <20 23 25 29 33 40 46 50
8ø 0.348 Throw, 4 - way 1-2 1-3 1-5 2-6 2-7 3-8 5-10 6-12 7-14
Feet 3 - way 1-4 2-6 3-8 4-10 5-11 6-13 8-17 10-20 11-22
2 - way 1-6 3-9 4-11 6-13 8-16 9-18 11-22 13-24 16-26
1 - way 2-8 4-11 6-14 8-16 9-19 11-22 14-25 16-28 19-30
Total Pressure, in. W.G. .019 .034 .054 .077 .105 .138 .215 .310 .422
Flow Rate, CFM 164 217 271 326 381 435 544 653 762
NC <20 20 25 28 33 37 45 >50 >50
10 ø 0.545 Throw, 4 - way 1-3 1-5 2-7 3-8 4-10 5-11 7-14 8-17 10-20
Feet 3 - way 1-7 3-9 5-11 7-14 8-16 9-18 11-23 14-27 16-29
2 - way 2-9 5-12 7-15 9-19 11-22 12-25 15-31 19-33 22-36
1 - way 3-11 7-15 9-19 11-23 13-27 15-30 19-35 23-38 27-41
Total Pressure, in. W.G. .023 .014 .065 .093 .127 .166 .259 .373 .507
Flow Rate, CFM 236 315 393 472 548 627 784 943 1098
NC <20 24 29 32 36 41 48 >50 >50
12 ø 0.785 Throw, 4 - way 1-5 2-7 3-9 5-11 6-13 7-14 9-18 11-22 13-26
Feet 3 - way 2-9 5-12 7-15 9-18 10-21 12-24 15-30 18-35 21-38
2 - way 4-12 7-16 10-20 12-24 14-28 16-32 20-40 24-43 28-47
1 - way 6-14 9-19 12-24 14-29 17-34 19-39 24-45 29-49 32-49
Total Pressure, in. W.G. .027 .048 .075 .108 .147 .192 .299 .431 .587
Flow Rate, CFM 318 424 530 636 742 848 1060 1272 1484
NC <20 25 30 34 39 44 >50 >50 >50
14 ø 1.06 Throw, 4 - way 1-6 3-9 5-11 6-13 8-16 9-18 11-23 13-27 16-32
Feet 3 - way 4-11 7-14 9-18 11-22 13-26 14-29 18-37 22-43 26-47
2 - way 6-15 10-20 12-25 15-30 17-35 20-40 25-49 30-53 35-58
1 - way 8-18 12-24 15-30 18-37 21-43 24-49 30-56 37-61 43-66
Total Pressure, in. W.G. .032 .056 .088 .127 .172 .225 .351 .506 .689
Flow Rate, CFM 417 556 695 834 973 1112 1390 1668 1946
NC 20 27 32 37 42 48 >50 >50 >50
16 ø 1.39 Throw, 4 - way 1-7 4-11 7-13 8-15 10-19 11-21 13-27 15-32 19-38
Feet 3 - way 6-13 9-16 11-21 13-26 16-31 17-34 21-44 24-51 31-56
2 - way 8-18 13-24 14-30 18-35 20-41 24-47 30-58 36-63 41-69
1 - way 10-21 15-28 18-35 22-44 25-52 29-59 36-60 43-72 51-79
Total Pressure, in. W.G. .038 .066 .104 .150 .204 .266 .414 .597 .813
Flow Rate, CFM 528 704 880 1056 1232 1408 1760 2112 2464
NC 21 29 34 40 45 >50 >50 >50 >50
18 ø 1.76 Throw, 4 - way 1-8 5-13 9-15 10-17 12-22 13-24 15-31 17-37 22-44
Feet 3 - way 8-15 11-18 13-23 15-30 19-36 20-39 24-51 28-59 36-65
2 - way 10-21 15-28 16-35 21-40 23-46 28-54 35-67 42-73 47-80
1 - way 12-24 18-32 21-40 26-50 29-61 34-69 42-65 49-83 60-92

• Throw values are given for Terminal Velocities of 100 and 50 fpm.
• NC values are based on a room absorption of 10 dB, re 10¯¹² watts.

22
CEILING DIFFUSER (CD)

Face - 2 1/2" (allow 1/2" for opening)

Neck

Face

Face - 2 1/2"
Neck

Face

23
CEILING DIFFUSER (CD)

24
ROUND CEILING DIFFUSER (RCD)

Opening = Face - 2"

Neck

H
Face

Round Ceiling Diffuser Return


(RCDR)

Opening = Face - 2"

Neck

Max. 4"
H

Face

Round Ceiling Diffuser Supply


(RCDS)

Aluminum alloy constructed round ceiling diffuser can be used as a supply or exhaust in
cooling, heating or ventilation application, with fully adjustable cores to provide horizontal or
vertical air pattern, removable inner core permit easy installation and access to duct.
Butterfly damper used for supply and its D shaped blade can adjust the air volume by
regulating the inner screw with screw driver.

Neck Face Height H CFM


SIZE
Inch mm Inch mm Inch mm Range
ø6" 5 5/8 144 12 3/4 325 2 3/8 60 60-315
ø8" 7 1/2 190 16 7/8 430 2 3/4 70 105-560
ø10" 9 1/2 240 20 7/8 530 3 1/2 90 165-870
ø12" 11 5/8 294 25 1/4 640 4 1/2 115 235-1255
ø14" 13 1/2 344 28 3/8 720 4 1/2 115 320-1710
ø16" 15 5/8 396 31 1/8 790 5 1/2 140 420-2240
ø18" 17 1/2 444 34 3/8 873 6 153 530-2830

1
ROUND CEILING DIFFUSER (RCD)

NECK VELOCITY
NECK NECK 300 400 500 600 700 800 900 1000 1100 1200 1400 1600
(FPM)
SIZE AREA
(inches) (Sq. Ft.) Velocity Pressure 0.006 0.010 0.016 0.023 0.031 0.040 0.051 0.063 0.075 0.090 0.122 0.160

Air Flow. CFM 60 80 100 120 135 155 175 195 215 235 275 315
Total H 0.024 0.041 0.065 0.093 0.126 0.162 0.207 0.255 0.304 0.365 0.494 0.648
6 Pressure
0.196 V 0.035 0.058 0.093 0.133 0.180 0.232 0.296 0.365 0.435 0.522 0.708 0.928
Dia.
Radius of Diff., Feet 2-3 2-4 3-5 3-5 4-6 4-6 5-7 5-7 5-7 6-8 6-8 7-9
NC <20 <20 <20 <20 <20 23 26 30 33 35 40 44
Air Flow. CFM 105 140 175 210 245 280 315 350 385 420 490 560
Total H 0.017 0.029 0.046 0.066 0.088 0.114 0.145 0.180 0.214 0.257 0.348 0.456
8 Pressure
0.349 V 0.026 0.044 0.070 0.101 0.136 0.176 0.224 0.277 0.330 0.396 0.537 0.704
Dia.
Radius of Diff., Feet 2-4 3-5 4-6 4-7 5-7 6-8 6-8 7-9 7-10 7-10 8-11 9-12
NC <20 <20 <20 21 26 31 34 37 40 44 48 >50
Air Flow. CFM 165 220 275 325 380 435 490 545 600 655 765 870
Total H 0.017 0.028 0.044 0.063 0.085 0.110 0.140 0.173 0.206 0.248 0.335 0.44
10 Pressure
0.545 V 0.025 0.041 0.066 0.095 0.128 0.165 0.210 0.260 0.309 0.371 0.503 0.659
Dia.
Radius of Diff., Feet 3-6 5-7 5-8 6-9 7-9 8-10 8-11 9-12 9-12 10-13 11-14 12-15
NC <20 <20 <20 <20 21 26 30 33 36 39 44 48
Air Flow. CFM 235 315 395 470 550 630 705 785 865 940 1100 1255
Total H 0.015 0.025 0.040 0.057 0.077 0.099 0.126 0.156 0.185 0.222 0.301 0.395
12 Pressure
0.785 V 0.022 0.036 0.058 0.083 0.112 0.144 0.184 0.227 0.270 0.324 0.439 0.576
Dia.
Radius of Diff., Feet 4-6 5-7 6-9 7-10 8-11 9-12 10-13 10-14 11-14 11-15 13-16 14-18
NC <20 <20 <20 <20 22 26 30 33 36 39 45 49
Air Flow. CFM 320 430 535 640 750 855 965 1070 1175 1285 1500 1710
Total H 0.014 0.024 0.038 0.055 0.074 0.096 0.122 0.151 0.180 0.216 0.293 0.384
14 Pressure
1.07 V 0.022 0.036 0.058 0.083 0.112 0.144 0.184 0.227 0.270 0.324 0.439 0.576
Dia.
Radius of Diff., Feet 4-7 6-8 7-10 8-11 9-12 10-13 11-15 12-16 13-16 13-17 15-19 16-23
NC <20 <20 <20 23 28 32 36 40 43 46 >50 >50
Air Flow. CFM 420 560 700 840 980 1120 1260 1400 1540 1680 1960 2240
Total H 0.014 0.023 0.037 0.053 0.071 0.092 0.117 0.145 0.173 0.207 0.281 0.368
16 Pressure
1.40 V 0.021 0.035 0.056 0.080 0.108 0.139 0.177 0.219 0.260 0.312 0.423 0.555
Dia.
Radius of Diff., Feet 5-7 7-10 8-12 10-13 11-15 12-16 13-17 14-18 15-19 15-20 17-21 19-23
NC <20 <20 <20 22 27 31 35 39 42 44 49 >50
Air Flow. CFM 530 710 885 1060 1240 1415 1595 1770 1945 2125 2480 2830
Total H 0.014 0.022 0.036 0.051 0.069 0.089 0.114 0.140 0.167 0.201 0.272 0.357
18 Pressure
1.77 V 0.022 0.037 0.059 0.084 0.114 0.147 0.187 0.231 0.275 0.330 0.448 0.587
Dia.
Radius of Diff., Feet 6-8 7-11 9-12 10-14 12-16 13-17 14-19 16-20 16-21 18-22 19-24 21-25
NC <20 <20 <20 21 26 30 34 37 40 43 48 >50
Air Flow. CFM 655 870 1090 1310 1525 1745 1960 2180 2400 2615 3050 3490
Total H 0.012 0.021 0.033 0.047 0.064 0.082 0.105 0.129 0.154 0.185 0.250 0.328
20 Pressure
2.18 V 0.023 0.039 0.062 0.090 0.121 0.156 0.199 0.246 0.293 0.351 0.476 0.624
Dia.
Radius of Diff., Feet 6-9 8-12 10-14 12-16 14-17 15-19 16-21 17-22 18-23 19-24 21-26 23-28
NC <20 <20 <20 21 26 30 34 38 40 43 48 >50

- NC Data based upon 10 dB room attenuation


- All pressure are in inches of water

2
ROUND CEILING DIFFUSER (RCD)

NECK VELOCITY
NECK NECK 300 400 500 600 700 800 900 1000 1100 1200 1400 1600
(FPM)
SIZE AREA
Velocity Pressure (in.
(inches) (Sq. Ft.) 0.006 0.010 0.016 0.023 0.031 0.040 0.051 0.063 0.075 0.090 0.122 0.160
w.g.)
CFM 60 80 100 120 135 155 175 195 215 235 275 315
6
0.196 Negative SP (in. w.g.) 0.022 0.037 0.059 0.084 0.114 0.146 0.187 0.230 0.275 0.330 0.446 0.586
Dia.
NC <20 <20 <20 <20 21 25 28 32 34 37 42 46
CFM 105 140 175 210 245 280 315 350 385 420 490 560
8
0.349 Negative SP (in. w.g.) 0.013 0.023 0.037 0.052 0.068 0.089 0.113 0.140 0.167 0.200 0.271 0.355
Dia.
NC <20 <20 <20 23 28 32 34 37 41 46 >50 >50
CFM 165 220 275 325 380 435 490 545 600 655 765 870
10
0.545 Negative SP (in. w.g.) 0.013 0.022 0.034 0.048 0.065 0.084 0.107 0.132 0.157 0.190 0.256 0.336
Dia.
NC <20 <20 <20 <20 23 28 32 35 38 41 46 50
CFM 235 315 395 470 550 630 705 785 865 940 1100 1255
12
0.785 Negative SP (in. w.g.) 0.011 0.018 0.029 0.041 0.055 0.071 0.090 0.112 0.132 0.158 0.215 0.282
Dia.
NC <20 <20 <20 <20 24 28 32 35 38 41 47 >50
CFM 320 430 535 640 750 855 965 1070 1175 1285 1500 1710
14
1.07 Negative SP (in. w.g.) 0.010 0.017 0.026 0.038 0.052 0.067 0.085 0.106 0.126 0.151 0.205 0.269
Dia.
NC <20 <20 20 25 30 34 38 42 45 48 >50 >50
CFM 420 560 700 840 980 1120 1260 1400 1540 1680 1960 2240
16
1.40 Negative SP (in. w.g.) 0.010 0.016 0.025 0.036 0.048 0.062 0.079 0.098 0.118 0.140 0.191 0.25
Dia.
NC <20 <20 <20 24 29 33 37 41 44 46 >50 >50
CFM 530 710 885 1060 1240 1415 1595 1770 1945 2125 2480 2830
18
1.77 Negative SP (in. w.g.) 0.010 0.014 0.024 0.034 0.046 0.059 0.076 0.092 0.110 0.133 0.180 0.236
Dia.
NC <20 <20 <20 23 28 32 36 39 43 45 50 >50
CFM 655 870 1090 1310 1525 1745 1960 2180 2400 2615 3050 3490
20
2.18 Negative SP (in. w.g.) 0.007 0.013 0.020 0.029 0.040 0.050 0.065 0.079 0.095 0.114 0.154 0.202
Dia.
NC <20 <20 <20 23 28 32 36 40 43 45 50 >50
- NC Data based upon 10 dB room attenuation
- All pressure are in inches of water

3
ROUND CEILING DIFFUSER (RCD)

Round ceiling diffuser return connected with duct by screw

Round ceiling diffuser supply connected with duct by screw

4
JET DIFFUSER (JD)

RABIE Round Jet Diffuser (RJD) is designed for areas where a long throw is needed. Inner
rings can be controlled in both horizontal and vertical directions. The diffuser is made of alu-
minum and polyester powder coated. One, two, three or four jet diffuser elements per panel
can be selected.
C

D
Dimensions (mm)
SIZE A B C D NO. OF RINGS
150 Ø 249 151 50 140 2
200 Ø 300 202 50 140 2
250 Ø 350 255 50 140 3
300 Ø 405 304 50 140 4
350 Ø 455 354 50 140 4
400 Ø 502 394 50 140 5
450 Ø 557 458 50 140 5

1
JET DIFFUSER (JD)

F
G
E

Dimensions (inches)
SIZE & QTY. E F G
8x2 29 15 14
8x3 43 15 14
8x4 57 15 14
10 x 2 33 17 16
10 x 3 49 17 16
10 x 4 65 17 16
12 x 2 37 19 18
12 x 3 55 19 18
12 x 4 73 19 18
14 x 2 41 21 20
14 x 3 61 21 20
14 x 4 81 21 20
16 x 2 45 23 22
16 x 3 67 23 22
16 x 4 89 23 22
18 x 2 49 25 24
18 x 3 73 25 24
18 x 4 97 25 24

2
Neck Velocity (fpm) 300 400 500 600 700 800 1000 1200 1400
SIZE Velocity Pressure (in. w.g.) 0.006 0.010 0.016 0.022 0.031 0.040 0.062 0.090 0.122
Deflection 0 22.5 0 22.5 0 22.5 0 22.5 0 22.5 0 22.5 0 22.5 0 22.5 0 22.5
CFM 110 140 180 210 250 280 350 420 490
Neck Area SP (in. w.g.) - - 0.010 0.020 0.020 .0.030 0.024 0.040 0.040 0.060 0.055 0.100 0.090 0.120 0.150 0.210 0.220 0.300
8"
sq. ft. 0.349 NC - - - 18 - 18 15 18 20 21 22 26 25 32 27 33 35 40
Throw (ft.) 14 12 18 17 20 18 22 20 24 21 26 23 28 25 30 27 32 28
CFM 170 220 280 330 390 440 550 660 770
Neck Area SP (in. w.g.) - - - 0.020 0.010 0.030 0.018 0.040 0.030 0.050 0.040 0.062 0.054 0.091 0.076 0.130 0.100 0.240
10"
sq. ft. 0.545 NC - - - - - 15 - 20 20 22 15 16 24 18 25 32 34 38
Throw (ft.) 21 18 24 20 26 21 28 24 30 27 32 28 34 31 38 33 40 35
CFM 240 320 400 480 550 630 790 950 1100
Neck Area SP (in. w.g.) - - - 0.010 - 0.025 0.035 0.040 0.040 0.050 0.050 0.100 0.050 0.090 0.060 0.100 0.100 0.200
12"
JET DIFFUSER (JD)

sq. ft. 0.785 NC - - - - - - - - - 20 18 22 22 32 31 38 35 42


Throw (ft.) 25 21 27 23 28 26 31 28 34 31 35 32 41 38 42 40 43 41
CFM 330 430 540 650 750 860 1070 1290 1500
Neck Area SP (in. w.g.) - - - - - 0.026 0.030 0.041 0.028 0.040 0.030 0.050 0.040 0.060 0.050 0.100 0.150 0.250
14"
sq. ft. 1.069 NC - - - - - - - 15 15 21 16 29 24 30 29 34 36 40
Throw (ft.) 27 23 30 26 33 31 37 33 40 36 41 39 43 41 52 46 59 50
CFM 420 560 700 840 980 1120 1400 1680 1960
Neck Area SP (in. w.g.) - - - - - 0.030 0.022 0.038 0.033 0.022 0.040 0.030 0.050 0.041 0.060 0.070 0.070 0.085
16"
sq. ft. 1.396 NC - - - - - - - - - 15 - 17 23 26 30 33 35 38
Throw (ft.) 30 27 34 32 38 36 41 39 43 41 46 43 54 48 62 54 70 60
CFM 540 720 900 1075 1255 1435 1795 2150 2500
Neck Area SP (in. w.g.) - - - - - 0.03 0.02 0.03 0.03 0.04 0.04 0.05 0.06 0.07 0.10 0.11 0.12 0.14
18"
sq. ft. 1.767 NC - - - - - - - 15 - 15 17 25 26 32 30 35 36 40
Throw (ft.) 35 32 40 37 42 40 47 44 50 47 55 50 63 56 71 67 80 72

DASHED LINE IN SP BOX INDICATES STATIC PRESSURE IS LESS THAN0.01 IN W.G.


DASHED LINE IN NC BOX INDICATES NOISE LEVEL IS LESS THAN 20.
NC LEVEL IS BASED ON 10dB ROOM ATTENUATION (pw re : 10-12 watts) WITH ONE DIFFUSER OPERATING.

3
JET DIFFUSER (JD)

RJD With Flexible duct connection ( Option F ) RJD With Round duct connection ( Option R )

RJD Fixed by Spring ( Option Sp ) RJD Multi elements Fixed by Screw RJD Multi elements Fixed by Clamp
( Option S ) ( Option C )

4
JET DIFFUSER (JD)

RABIE Nozzle Jet Diffusers (NJD) are used for preference where the supply air from the dif-
fuser has to travel a large distance to the occupied zone such as in concert halls, theatres,
airports, museums, malls, sport halls etc.
The aerodynamically efficient shape of the jet nozzles results in low noise characteristics.
The discharge nozzle and face cover ring are in aluminum. The duct connection element and
saddle connection are in galvanized sheet steel.
The Jet Nozzle surface is powder coated in white (RAL 9016) or can be supplied in other
RAL colors.
ØD

ØA

ØE
ØB
ØF

ØD ØA ØB C ØE ØF
160 85 250 120 225 200
200 110 295 150 270 245
250 140 345 190 320 295
315 175 415 265 390 360

5
JET DIFFUSER (JD)

Throw Terminal
Size
10 m 20 m 30 m Velocity
(mm)
LPS NC LPS NC LPS NC (m/s)
Ø 160 40 <20 80 <20 120 32
Ø 200 50 <20 100 <20 140 25
0.25
Ø 250 60 <20 130 <20 180 22
Ø 315 80 <20 170 <20 250 23
Ø 160 80 <20 160 39 230 50
Ø 200 100 <20 210 35 310 46
0.5
Ø 250 130 <20 260 31 390 42
Ø 315 170 <20 330 27 500 40
Ø 160 160 39 - - - -
Ø 200 210 35 410 48 - -
1
Ø 250 260 33 520 50 - -
Ø 315 330 28 660 48 990 52

Correction for swivel angle = ± 30°


Size 160 200 250 315
LWA/LWNC +3 +3 +2 +2

Pressure Drop

Total Pressure Drop (Pa)

315 250 200 160

6
JET DIFFUSER (JD)

7
JET DIFFUSER (JD)

Rabie Drum Jet Diffuser (DJD) is a high capacity unit specifically designed for the relatively large
spaces such as warehouses, sport halls or factory units etc. Where a long throw and high change
per hour rate is required. The unit is constructed with aluminum and consists of the drum which can
direct the air by adjusting up or down at any degree up to 30° deflection. The drum holds group-
operated vertical blades in order to enable deflection in horizontal manner.
Rabie (DJD) has a standard finish of high quality, hard baked electrostatic powder coating for long
life and easy cleaning, Standard color is white RAL 9016, other colors are available upon request.

8
JET DIFFUSER (JD)

MODEL A B W H C D
DJD A 300 225 255 180 23 55
DJD B 350 225 305 180 23 55
DJD C 500 225 455 180 23 55
DJD D 655 225 610 180 23 55
DJD E 555 300 510 255 23 55
DJD F 705 300 660 255 23 55
DJD G 860 300 815 255 23 55
DJD H 960 300 915 255 23 55

A & B are exact Face Size

W & H are Nominal Neck Size

All sizes are in mm

9
JET DIFFUSER (JD)

Ps-Pressure drop - Pa

10
JET DIFFUSER (JD)

Option A: By Screw Option B: By Screw


and collar (Duct) (Wall mounted)

11
JET DIFFUSER (JD)

NOTES

12
DISC VALVE (DV)

RABIE Disc Valve is manufactured from high quality steel and polyester powder coated.
Center core is adjustable by screw and nut for air control.
The outer frame is fitted with a foam rubber gasket.
The DV is widely used for exhaust in wash rooms.

1
DISC VALVE (DV)


E F

Wall Opening Size




Disc

Mounting Frame
Foam Gasket

INCHES
Nominal GØ
AØ BØ CØ DØ E F
Size (Opening Size)
4" 5 3/8 3 3 7/8 5 1/8 1 5/8 1 1/8 4 1/8
6" 8 4 3/4 5 7/8 7 2 1 1/8 6 1/8
8" 9 7/8 6 1/4 7 3/4 9 1/8 2 1/2 1 1/8 8 1/8

2
DISC VALVE (DV)

+ -
Setting

Size 4”
Air Flow
Setting 15 20 25 30 35 40 45 50 60 70 80 90 100
(CFM)
SP 0.3 0.6 1
-3/8"
NC <20 20 25
SP - 0.2 0.4 0.6 0.8 1.1
-1/4"
NC - <20 <20 23 25 26
SP - - 0.2 0.3 0.5 0.6 0.8 1
-1/8"
NC - - <20 <20 22 24 26 28
SP - - - 0.2 0.3 0.5 0.6 0.8 1 1.2
0
NC - - - <20 20 22 24 26 32 34
SP - - - - 0.2 0.3 0.4 0.5 0.6 0.8 1.2
1/8"
NC - - - - <20 <20 22 24 26 32 38
SP - - - - - 0.2 0.3 0.3 0.5 0.6 0.8 1.1
1/4"
NC - - - - - <20 <20 22 25 28 33 42
SP - - - - - - 0.2 0.3 0.3 0.5 0.6 0.8 1.1
3/8"
NC - - - - - - <20 <20 23 25 29 38 45
SP - - - - - - - 0.2 0.3 0.3 0.4 0.6 0.8
1/2"
NC - - - - - <20 20 25 26 32 38

Size 6”
Air Flow
Setting 30 35 40 50 60 70 80 90 100 120 140 160 180
(CFM)
SP 0.3 0.5 0.6 1.4
-1/4"
NC <20 21 24 32
SP - 0.2 0.3 0.4 0.6 0.8 1.1
-1/8"
NC - <20 <20 21 25 31 34
SP - - - 0.2 0.3 0.4 0.6 0.8 1
0
NC - - - <20 20 23 26 34 40
SP - - - - - - 0.2 0.3 0.4 0.6 0.8 1.1
1/4"
NC - - - - - - <20 <20 22 31 35 42
SP - - - - - - - 0.2 0.3 0.4 0.6 0.8 1
1/2"
NC - - - - - - - <20 <20 24 28 35 45

Size 8”

Air Flow
Setting 40 50 60 70 80 100 120 140 160 180 200 220 240
(CFM)
SP 0.4 0.6 0.9
- 3/4
NC 22 31 35
SP - 0.2 0.3 0.4 0.6
- 5/8
NC - <20 20 23 26
SP - - 0.2 0.2 0.3 0.5 0.7
- 3/8
NC - - <20 <20 22 28 33
SP - - - - - 0.3 0.4 0.5 0.7 0.9
- 1/4
NC - - - - - 22 26 30 34 38
SP - - - - 0.2 0.3 0.3 0.5 0.6 0.7
0
NC - - - - - <20 23 26 31 36 38
SP - - - - 0.2 0.2 0.3 0.4 0.5 0.6 0.7
1/4
NC - - - - - - <20 23 26 30 32 36 38
SP - - - - - - - - 0.3 0.3 0.4 0.5 0.6
3/8
NC - - - - - - - - 23 26 28 32 35
SP - - - - - - - - 0.2 0.3 0.3 0.3 0.4
5/8
NC - - - - - - - - <20 23 25 27 33
SP - - - - - - - - - 0.2 0.2 0.3 0.3
3/4
NC - - - - - - - - - 23 24 25 28
SP - - - - - - - - - 0.2 0.2 0.3
1
NC - - - - - - - - <20 24 25

* SP is the static pressure in Inch wg

3
DISC VALVE (DV)

4
FRESH AIR LOUVER (FAL)

RABIE fresh air louver used for exhaust & fresh air is composed of a set of horizontal
mounted fixed blades and inclined down 30° and spaced 1 3/8” (35mm) for small blade
type & 2 inch (50mm) for big blade type, which allows air to pass through it while keeping
out unwanted elements such as water, dirt etc.
Frame and blades are manufactured from extruded aluminum alloy (6063-T6) and are
polyester powder coated RAL (9016 or 9010, other colors available on request).
The FAL is designed for both intake and exhaust opening.

1
FRESH AIR LOUVER (FAL)

Options
• Bird or insect screen (Galvanized steel)
• Opposed blade damper.
• Removable and washable air filters, 1 or 2 inches thick.

2
FACE = NECK + 70 FACE = NECK + 60

2” 1-3/8” 1-5/16”
1-3/8”
(50) (35) (35) (30)
FRESH AIR LOUVER (FAL)

(45)
1-3/4”

(78)
3-5/64”
NECK
NECK

3
FRESH AIR LOUVER (FAL)

FAL-35. Free Area for Listed Sizes (ft²)

Height Width (inch)


(inch) 12 16 20 24 28 32 36 40 44 48 52 56 60
12 0.24 0.34 0.44 0.54 0.64 0.64 0.74 0.84 0.94 1.04 1.15 1.25 1.35
16 0.36 0.50 0.65 0.80 0.95 0.95 1.10 1.25 1.39 1.54 1.69 1.84 1.98
20 0.47 0.67 0.86 1.05 1.25 1.26 1.46 1.65 1.84 2.04 2.23 2.43 2.62
24 0.59 0.83 1.07 1.31 1.55 1.57 1.81 2.06 2.30 2.54 2.78 3.02 3.26
28 0.71 0.99 1.28 1.57 1.85 1.89 2.17 2.46 2.75 3.03 3.32 3.61 3.89
32 0.82 1.16 1.49 1.82 2.15 2.20 2.53 2.86 3.20 3.53 3.86 4.20 4.53
36 0.94 1.32 1.70 2.08 2.46 2.51 2.89 3.27 3.65 4.03 4.41 4.79 5.16
40 1.06 1.48 1.91 2.33 2.76 2.82 3.25 3.67 4.10 4.52 4.95 5.38 5.80
44 1.13 1.58 2.04 2.50 2.95 3.01 3.47 3.92 4.38 4.84 5.29 5.75 6.21
48 1.24 1.75 2.25 2.75 3.25 3.32 3.83 4.33 4.83 5.33 5.84 6.34 6.84
52 1.36 1.91 2.46 3.01 3.56 3.64 4.19 4.73 5.28 5.83 6.38 6.93 7.48
56 1.48 2.07 2.67 3.26 3.86 3.95 4.54 5.14 5.73 6.33 6.92 7.52 8.11
60 1.60 2.24 2.88 3.52 4.16 4.26 4.90 5.54 6.18 6.83 7.47 8.11 8.75

For sizes not included in the table, the following formula can be used:
Free Area (ft2) = 4.3 x W x H - 0.11 x W - 0.07 x H
While W & H are in feet.

FAL-50. Free Area for Listed Sizes (ft²)

Height Width (inch)


(inch) 12 16 20 24 28 32 36 40 44 48 52 56 60
12 0.39 0.55 0.70 0.85 1.01 1.05 1.20 1.36 1.51 1.66 1.82 1.97 2.12
16 0.55 0.76 0.97 1.18 1.39 1.46 1.67 1.88 2.09 2.31 2.52 2.73 2.94
20 0.70 0.97 1.24 1.51 1.78 1.87 2.14 2.41 2.68 2.95 3.22 3.49 3.76
24 0.85 1.18 1.51 1.84 2.17 2.28 2.61 2.93 3.26 3.59 3.92 4.25 4.57
28 1.01 1.39 1.78 2.17 2.55 2.69 3.07 3.46 3.85 4.23 4.62 5.00 5.39
32 1.16 1.60 2.05 2.49 2.94 3.09 3.54 3.98 4.43 4.87 5.32 5.76 6.21
36 1.31 1.82 2.32 2.82 3.32 3.50 4.01 4.51 5.01 5.52 6.02 6.52 7.03
40 1.47 2.03 2.59 3.15 3.71 3.91 4.47 5.03 5.60 6.16 6.72 7.28 7.84
44 1.62 2.24 2.86 3.48 4.10 4.32 4.94 5.56 6.18 6.80 7.42 8.04 8.66
48 1.77 2.45 3.13 3.81 4.48 4.73 5.41 6.09 6.76 7.44 8.12 8.80 9.48
52 1.92 2.66 3.40 4.13 4.87 5.14 5.87 6.61 7.35 8.08 8.82 9.56 10.29
56 2.08 2.87 3.67 4.46 5.26 5.55 6.34 7.14 7.93 8.73 9.52 10.32 11.11
60 2.23 3.08 3.94 4.79 5.64 5.96 6.81 7.66 8.51 9.37 10.22 11.07 11.93

For sizes not included in the table, the following formula can be used:
Free Area (ft2) = 5.75 x W x H - 0.15 x W - 0.07 x H
While W & H are in feet.

4
FRESH AIR LOUVER (FAL)

Knowing the volumetric flow rate required and maximum allowable pressure drop, you can use the
performance chart and Free area table to estimate an appropriate size.

Example:
If a fan requires to suck 6000 cfm through a louver with maximum pressure drop 60 Pa. Estimate the
required size.

Solution— At the chart, pivot the pressure drop 60 Pa then intersect with “Intake” line to get the free
air velocity as 1200 fpm approximately.
- Free area = flow rate / free air velocity = 6000 / 1200 = 5 ft2
- From the table, select any sizes give at least 5 ft2 free area
e.g. (56 x 40)in. or (48 x 48)in.

5
FRESH AIR LOUVER (FAL)

2 4 5
6

1 3

1. Fresh Air Louver. 4. Volume Control Damper (or any type of dampers)
2. Bird or Insect Screen (Galvanized Steel). 5. GI Sleeve (20 gauge minimum).
3. Aluminum Filter (Washable) 1 or 2 Inches. 6. Duct Mate Flange (MS Steel Angle) 35 x 30mm.

Note: All arrangements can be customized to suit the required application in terms of components, filter thick-
ness and operation, damper details and operation, and sleeve details.

6
FRESH AIR LOUVER (FAL)

Ordering Code

7
FRESH AIR LOUVER (FAL)

Penthouse (RPH)

RABIE Penthouse Louvers (RPH) are hood units designed for air intake, pressure-relief and exhaust ap-
plications, mounted on roofs.
RPH shall be constructed of heavy gauge extruded aluminum. The blades are of 1.2mm thick extruded
aluminum and are polyester powder coated with your choice of color (mill finish is standard).
The assembly is provided with bird screen to prevent the entry of birds to the louver as an option. Also
25mm thick aluminum washable filters available on request, which could be removed for cleaning.

Principle of Operation
The atmospheric pressure (Pa) surrounding a penthouse is virtually uniform.
As the system works (fans start suctioning), the static pressure inside a penthouse shall be lower than
the atmospheric pressure outside. And because of this pressure difference the air is drawn into the
penthouse.
Since the suction shall be greater near the throat than the top of the penthouse, the air velocity at the
blades near the throat (bottom of penthouse) shall be more than the velocity at the top blades.
Due to this fact, a short penthouse shall have better performance than a tall penthouse provided that
suitable free area is selected (free area shall almost be equal to pressure area).

RPH Selection
Pressure requirements are minimized when the area of the opening in the penthouse base (duct area) is
approximately equal to the effective pressure area. Therefore the recommended penthouse heights in
the table following are selected for this minimum pressure condition. Increasing the height will not further
reduce the pressure requirements.
The areas in the Recommended Penthouse Heights table following refer to the duct opening in the base
of the penthouse. Each area corresponds to a given width W, length L and height H.
Example: Select a penthouse for exhausting 2800 LPS from a 750mm x 1200mm duct opening. Deter-
mine the pressure requirement.
From the Recommended Penthouse Heights table , the height is 650mm.
The cross sectional area of a 750 x 1200 mm duct is 0.93 m² (also shown in the table).
Velocity then equals to flow divided by area (2.800/0.93 = 3.0 m/s).
From the table of pressure requirement, we can get the required pressure to be 17 Pa.

8
FRESH AIR LOUVER (FAL)

Recommended Penthouse Heights mm


W, mm L, mm 300 400 500 600 750 900 1200 1500 1800 2100 2400 2700 3000
H, mm 350 375 375 400 400 425 425 450 450 450 475 475 475
300
A, m² 0.09 0.12 0.16 0.19 0.23 0.28 0.37 0.46 0.56 0.65 0.74 0.84 0.93
H, mm 400 400 425 450 475 500 500 525 525 550 550 550
400
A, m² 0.17 0.21 0.25 0.31 0.37 0.5 0.62 0.74 0.87 0.99 1.11 1.24
H, mm 450 475 500 525 550 575 575 600 625 625 625
500
A, m² 0.26 0.31 0.39 0.46 0.62 0.77 0.93 1.09 1.24 1.35 1.55
H, mm 500 525 550 600 625 650 650 675 675 700
600
A, m² 0.37 0.46 0.56 0.74 0.93 1.11 1.3 1.49 1.67 1.86
H, mm 550 600 650 700 725 750 775 775 800
750
A, m² 0.58 0.7 0.93 1.16 1.39 1.63 1.86 2.09 2.32
H, mm 675 700 750 775 825 850 875 875
900
A, m² 0.84 1.11 1.39 1.67 1.95 2.23 2.51 2.79
H, mm 775 850 900 950 1000 1025 1050
1200
A, m² 1.49 1.86 2.23 2.6 2.97 3.34 3.72
H, mm 950 1000 1050 1100 1150 1200
1500
A, m² 2.32 2.79 3.25 3.72 4.18 4.65
H, mm 1075 1125 1225 1275 1325
1800
A, m² 3.34 3.9 4.46 5.02 5.57
H, mm 1250 1325 1375 1425
2100
A, m² 4.55 5.2 5.85 6.5
H, mm 1375 1450 1525
2400
A, m² 4.55 6.69 7.43
H, mm 1525 1600
2700
A, m² 7.52 8.36
H, mm 1675
3000
A, m² 9.29

Pressure requirements for extruded Aluminum Penthouse.


Velocity, m/s*** 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5
Intake* -2 -4 -7 -11 -15 -22 -28 -36 -43 -53 -63 -74 -86 -98
Exhaust* 2 4 8 12 17 24 31 39 48 58 69 82 95 108
* Total pressure, Pa Flow = Velocity × W × L /1000 (L/s)
** Velocity corresponding to the Duct Area or effective pressure area, whichever is less.

9
SAND TRAP LOUVER (STL)

RABIE Sand Trap louvers are very effective in trapping sand while having attractive and
aesthetic look that meets most architectural needs. Sand Trap louvers are constructed
from two sets of inverted C-Channels mounted vertically. The Louver has self emptying
holes at the bottom through which the trapped sand is expelled out smoothly. Frame and
blades are made from extruded aluminum alloy (6030-T6) polyester powder coated (RAL
9016 or 9010). Other colors are available on request.
Sand Trap louver allows air flow entry while separating and trapping sand from the air.

• Removable and washable air filters 1 or 2 inches (Aluminum).


• Bird or Insect screen (Galvanized steel).

1
SAND TRAP LOUVER (STL)

Sand Drain Holes

3-7/8” 2”
Blades

H + 2”

H
W + 2”
3” 1”

Sand Chute For louver heights more than 1.5 meter, intermediate
2”

reinforcement with transom and sand chute are used.

3”
2-8/8” 1”

2
SAND TRAP LOUVER (STL)

Example:
If a fan requires to suck 6000 cfm through a louver with maximum pressure drop 60 Pa. Esti-
mate the required size.

Solution—At the chart, pivot the pressure drop 60 Pa then intersect with the pressure drop
curve to get the face velocity as 300 fpm approximately.

-Minimum required Area = flow rate / face velocity = 6000 / 300 = 20 ft 2

-Select any sizes give at least 20 ft2


e.g. (4.5 x 4.5) ft. or (6.7 x 3) ft.

Test results conducted on similar equipment Indicate a


typical efficiency of 80% on AC coarse (20 - 200 microns)
and 50% on AC fine test duct (1 to 70 microns) at a face veloci-
CFM = H” x W” x Air Face Velocity (fpm)
ty of 1 m/s.
144

PRESSURE DROP
EFFICIENCY

FACE VELOCITY BASED ON TOTAL AREA

3
SAND TRAP LOUVER (STL)

1. Sand Trap Louver 4. Volume Control Damper (or any type of dampers)
2. Bird or Insect Screen (Galvanized Steel) 5. GI Sleeve (20 gauge minimum)
3. Aluminum Filter (Washable) 1 or 2 Inches 6. Duct Mate Flange (MS Steel Angle) 35 x 30mm.

Note : All arrangements can be customized to suit the required application in terms of components, filter thick-
ness and operation, damper details and operation, and sleeve details.

4
SAND TRAP LOUVER (STL)

Ordering Code

5
SAND TRAP LOUVER (STL)

6
SAND TRAP LOUVER (STL)

7
SAND TRAP LOUVER (STL)

8
BACK DRAFT DAMPERS

RABIE Back Draft Dampers are non-return dampers designed for automatic isolation of
individual sections of an air conditioning system, allowing airflow in one direction only.
RABIE has developed three types of Back Draft Dampers as following:
GSH Light Back Draft Damper (Gravity Shutter) is constructed of extruded Aluminum
blades and are rated for velocities up to 1500 fpm (7.5 m/s) and pressure up to 2” WG
(500 Pa). GSH is used mainly for constant airflow systems.
BDD Back Draft Damper is constructed of galvanized blades, and rated for velocities up
to 2500 fpm (12.5 m/s) and pressure up to 3” WG (750 Pa). BDD has an elevated open
pressure than GSH. BBD is mainly used for variable airflow systems.
Both GSH and BDD are used in intake and discharge openings in air conditioning
systems. The blades open by the airflow, and close by gravity. When installed after a
fan, the damper will prevent the wind from causing the fan to run backwards, and will
prevent the ingress of rain, dirt or birds into the system when the fan switches off. In a
multi fan installation, the damper prevents back draught through the non-operating fans.
PRD Pressure Relief Damper is a back draft damper having an adjustable start to open
pressure. PRD uses counter weights to fine-tune the settings of start to open pressure
and this is adjustable from 0.25” to 4.0” WG (60 to 1000 Pa). PRD is rated for velocities
up to 3000 fpm (15.24 m/s) and pressure up to 13.5” WG (3.5 kPa).
PRD is to protect HVAC systems and industrial processes by relieving air pressure. It
would relieve either an unexpected overpressure (e.g. due to closing doors in a
staircase) or a negative pressure (e.g. downstream of a rapidly closing fire damper in a
duct).

1
BACK DRAFT DAMPERS

• Frame of extruded aluminum for GSH-W (wall mounted) and of galvanized steel hat
channel 100mm×15mm×1mm (4 in.×5/8 in.×20 ga.) for GSH-D (Duct mounted).
• Blades of Extruded Aluminum
• Blade Seals of rubber (optionally sponge).
• Linkage: None
• Finish of polyester powder coated (RAL 9016). Other colors on request.
• Maximum Single Section Size: 1200mm W × 2400mm H (48 in. × 96 in.)
• Minimum Size: 150mm W × 150mm H (6 in. × 6 in.)

• Frame of galvanized steel hat channel 125mm×23mm×1.5mm (5 in.×7/8


in.×16ga.). Optionally with One side flange for wall mounting.
• Blades of galvanized steel
• Blade Seals of rubber (optionally sponge).
• Linkage: face linkage (optionally side linkage)
• Finish of MF or polyester powder coated (RAL 9016). Other colors on request.
• Maximum Single Section Size: 1200mm W × 2400mm H (48 in. × 96 in.)
• Minimum Size: 150mm W × 150mm H (6 in. × 6 in.)

• Frame of galvanized steel channel 150mm×25mm×1.5mm (6 in.×1 in.×16 ga.)


• Blades of Airfoil shape, 1-U shape or 2-V shape 1mm (20 ga.) galvanized steel
• Blade Seals of rubber.
• Axles of plated steel rod.
• Linkage: Side linkage (optionally face linkage)
• Pressure Set of Adjustable arms and weights.
• Finish of Mill galvanized.
• Pressure Relief range 60 Pa (0.25 in. wg) to 1000 Pa (4.0 in. wg)
• Back Pressure range 1500-3500 Pa (6.0 - 13.5 in. wg)
• Velocity 15.24 m/s (3000 fpm)
• Temperature range –40°C (-40°F) to 120°C (250°F)
• Size Limitations:
• Maximum Single Section Size: 1200mm W × 2400mm H (48 in. × 96 in.)
• Maximum Double Section Size: 2400mm W×2400mm H (96 in. × 96 in.)
• Minimum Size: Single blade 150mm W × 150mm H (6 in. × 6 in.)

2
BACK DRAFT DAMPERS

GSH-W (Wall Mounted) GSH-D (Duct Mounted)

BDD PRD

Max. 7" [175] 6" [150]

W×H

Note:
W and H are furnished 5mm less than nominal size
except for PRD which is exact to nominal size.

3
BACK DRAFT DAMPERS

Wall Mounted 1-3/4”


GSH-W

FACE = NECK + 60

NECK

SCREW

Duct Mounted
GSH-D
RIVET

DUCT
SYSTEM 1

AIR FLOW

DUCT
SYSTEM 2

Unit 1 in Operation
Unit 2 in Stand-by

4
VOLUME CONTROL DAMPER (VCD)

VCDF-H (WITH HAND QUADRANT) VCDF-M (WITH ACTUATOR)

• Volume control damper is made of single or multi blades.


• Blades edge seal can be fitted for low leakage requirements.
• Hand locking quadrant is provided for manual operation.
• Extended shaft and motor base is provided for motorized operation.
• The blades are mounted on nylon bearing and operated by external linkage.
• Opposed blade action on request.

1
VOLUME CONTROL DAMPER (VCD)

Frame: Flanged Steel Chanel 6” × 1” × 16 gauge galvanized.


Other sizes are available on request.
Blade: 3-V 16 gauge galvanized steel (Reinforced with 3 longitudinal
“structurally designed vees”)
Bushing: Nylon bearings
Control shaft : 1/2” × 1/2” square steel spindle.
Operation: Hand Quadrant For manual operation.
Actuator for motorized.
Finish: Mill galvanized.
Minimum size: 4”x 4”
Maximum size: 48”x72” as a single section.
Multiple section assembly of unlimited size, where each section
operates independently. For details of multiple sections consult
Rabie Al Takyeef Factory

1. Landing Angle 4. Bushing 7. Quadrant


2. Side Linkage 5. Blade
3. Casing 6. Spindle

Parallel Blades Opposed Blades


3
3

4 2

4 5
6 7

1
2

2
VOLUME CONTROL DAMPER (VCD)

5 1 6”

1”
6

H+2”

H
H
2

W
W+2”

Standard sizes
W in inches H in inches Number of Blades
4 4 1
6 6 1
8 8 1
10 10 2
12 12 2
14 14 2
16 16 2
18 18 2
20 20 3
22 24 3
24 28 3
26 32 4
28 36 4
30 40 5
32 44 5
34 48 5
36 52 6
38 56 6
40 60 7
42 64 7
44 68 8
48 72 8

3
VOLUME CONTROL DAMPER (VCD)

VCDC-H (WITH HAND QUADRANT) VCDC-M (WITH ACTUATOR)

• Volume control damper is made of single or multi blades.


• Frame is of galvanized steel construction.
• Blades are of single skin inter locking galvanized steel.
• Hand locking quadrant is provided for manual operation.
• Extended shaft and motor base is provided for motorized operation.
• The blades are mounted on Nylon bearing and operated by external and internal linkage.
• Opposed blade action on request.

4
VOLUME CONTROL DAMPER (VCD)

Frame: Cee cleat and S slip Shape 6” × 16 gauge galvanized.


Other sizes are available on request.
Blade: 3-V 16 gauge galvanized steel (Reinforced with 3 longitudinal
“structurally designed vees”)
Bushing: Nylon bearings
Control shaft : 1/2” × 1/2” square steel spindle.
Operation: Hand Quadrant For manual operation.
Actuator for motorized.
Finish: Mill galvanized.
Minimum size: 4”x 4”
Maximum size: 48”x72” as a single section.
Multiple section assembly with unlimited size, where each section
operates independently. For details of multiple sections consult
Rabie Al Takyeef Factory

1. Landing Angle 3. Casing 5. Blade


2. Side Linkage 4. Bushing 6. Spindle

2
5

5
VOLUME CONTROL DAMPER (VCD)

6”
1

2
H

H
6

Standard sizes
W in inches H in inches Number of Blades
4 4 1
6 6 1
8 8 1
10 10 2
12 12 2
14 14 2
16 16 2
18 18 2
20 20 3
22 24 3
24 28 3
26 32 4
28 36 4
30 40 5
32 44 5
34 48 5
36 52 6
38 56 6
40 60 7
42 64 7
44 68 8
48 72 8

6
VOLUME CONTROL DAMPER (VCD)

VCDS-H (WITH HAND QUADRANT) VCDS-M (WITH ACTUATOR)

• Volume control damper is made of single or multi blades.


• Frame is of galvanized steel, constructed with two circular spigot duct connections.
• Blades are of single skin inter locking galvanized steel.
• Hand locking quadrant is provided for manual operation.
• Extended shaft and motor base is provided for motorized operation.
• The blades are mounted on bearing and operated by external and internal linkage.
• Opposed blade action on request.

Frame: Steel Chanel 6” / 12” × 16 gauge galvanized.


Other sizes are available on request.
Blade: 3-V 16 gauge galvanized steel (Reinforced with 3 longitudinal
“structurally designed vees”)
Collar: 20 gauge galvanized steel
Bushing: Nylon bearings
Control shaft : 1/2” × 1/2” square steel spindle.
Operation: Hand Quadrant For manual operation.
Actuator for motorized.
Finish: mill galvanized.
Minimum size: 4” diameter
Maximum size: 36” diameter
For larger diameters consult Rabie Al Takyeef Factory

7
VOLUME CONTROL DAMPER (VCD)

1. Landing Angle 3. Casing 5. Blade


2. Side Linkage 4. Bushing 6. Spindle

Standard sizes
Ø in inches Number of Blades
4 1
6 2
8 2
10 2
12 3
14 3
16 3
18 4
20 4
22 4
24 5
26 5
28 5
30 6
32 6
34 6
36 7

8
VOLUME CONTROL DAMPER (VCD)

VCDO-H (WITH HAND QUADRANT) VCDO-M (WITH ACTUATOR)

• Volume control damper is made of single or multi blades.


• Frame is of galvanized steel casing, constructed with two oval spigot duct connections.
• Blades are of single skin inter locking galvanized steel.
• Hand locking quadrant is provided for manual operation.
• Extended shaft and motor base is provided for motorized operation.
• The blades are mounted on bearing and operated by external and internal linkage.
• Opposed blade action on request.

Frame: Steel Chanel 6” / 12” × 16 gauge galvanized.


Other sizes are available on request.
Blade: 3-V 16 gauge galvanized steel (Reinforced with 3 longitudinal
“structurally designed vees”)
Collar: 20 gauge galvanized steel
Bushing: Nylon bearings
Control shaft : 1/2” × 1/2” square steel spindle.
Operation: Hand Quadrant For manual operation.
Actuator for motorized.
Finish: mill galvanized.
Minimum size: 6”x 4”
Maximum size: 36”x20”
For larger sizes consult Rabie Al Takyeef Factory

9
VOLUME CONTROL DAMPER (VCD)

1. Landing Angle 3. Casing 5. Blade


2. Side Linkage 4. Bushing 6. Spindle

Standard sizes
B in inches A in inches Number of Blades
6 4 1
8 6 2
10 8 2
12 10 2
14 12 3
16 14 3
20 16 3
24 18 4
36 20 4

10
VOLUME CONTROL DAMPER (VCD)

VCDR- H (WITH HAND QUADRANT) VCDR-M (WITH ACTUATOR)

Dampers can be manual with locking quadrant or motorized with different sizes of actuator.

Casing and Blade: Gauge 20 galvanized Steel for up to 10’’ size, gauge 18 for
up to 14’’ size and gauge16 for higher sizes.
Bushing: Brass bearings
Control shaft: 1/2” round bar steel.
Hand Quadrant: For manual operation.
Finish: Mill galvanized.
Minimum size: ø6” in single blade construction.
Maximum size: ø24” in single blade construction.

11
VOLUME CONTROL DAMPER (VCD)

1. Blade 2. Casing 3. Drive shaft / spindle

1”
2 1

3
Ø”

L=Ø

12
VOLUME CONTROL DAMPER (VCD)

FASTENING SCREW DAMPER


OR RIVET

ROUND DUCT

ROUND DAMPER LYO COUPLING


FASTENING SCREW
OR RIVET

ROUND DUCT

ROUND DAMPER
FASTENING SCREW
OR RIVET

ROUND DUCT ROUND FITTING

13
VOLUME CONTROL DAMPER (VCD)

14
VOLUME CONTROL DAMPER (VCD)

15
VOLUME CONTROL DAMPER (VCD)

16
FIRE DAMPERS (FD)

Model FDI meets


the requirements
for fire dampers
established by
Underwriters
Laboratories
standard 555
(Listing # R27026)

Model FDI is approved for use in wall, floor and partitions with fire resistance ratings of 3
hours or more. This model carries a 3 Hour UL fire damper label.. The UL 555 classifies
dynamic rated fire dampers for use in HVAC systems that are automatically shut down in
the event of fire.

• Folding blades fire dampers designed impede to stop the spread of fire throughout
ventilation “duct” systems.
• Curtain blades fire dampers are suitable for installation in walls, floors, ceilings, doors
and partitions.
• Wide choice of sizes suitable for low, medium or high velocity application.
• Fire dampers are fitted with 72°C (165°F) fusible links [UL listed].

1
FIRE DAMPERS (FD)

1. Stainless steel closure spring. 3. Fusible link (72°C) UL listed 5. Galvanized steel casing
2. Locking ramp 4. Top blades are riveted to frame 6. Galvanized steel blades

5 5

1 6

2 2

FDI – OPEN FDI – CLOSED

4 4

6
3

1
5

5 FDI – OPEN
HORIZONTAL MOUNTING

2 2

FDI – OPEN FDI – CLOSED


VERTICAL MOUNTING VERTICAL MOUNTING

2
FIRE DAMPERS (FD)

4 7/16”

H
H

Isometric View Sectional Side View


Dimensions H and W shall be furnished approximately 5mm undersize the nominal height and width of
duct.

Frame Built of 20 gauge galvanized


Blade 20 gauge galvanized steel.
Finish Mill galvanized.
Fusible link 72°c ( 165° F ) UL listed.
Spring Stainless steel closure springs.
Fire rating 3 hours.
Minimum size 4”x 6”
Maximum size 36”x36” as a single section.
Multiple section assembly with unlimited size, where each
section operates independently. For detail of multiple sections
consult Rabie Al Takyeef Factory

3
FIRE DAMPERS (FD)

4
FIRE DAMPERS (FD)

1. Stainless steel closure spring. 3. Fusible link (72°C) UL listed 5. Galvanized steel casing
2. Locking ramp 4. Top blades are riveted to frame 6. Galvanized steel blades

Y (inch)
H (inch)
FDO FDR | FDSR | FDSO
4 5 6
5 6 7 1/4
6 7 1/8 8 1/4
7 8 1/8 9 3/8
8 9 1/4 10 3/8
9 10 1/4 11 3/8
10 11 1/2 12 5/8
11 12 1/2 13 5/8
12 13 3/8 14 3/4
13 14 5/8 15 3/4
14 15 1/2 17
15 16 3/4 18
16 17 3/4 19 1/8
17 18 7/8 20 1/8
18 19 7/8 21 3/8
19 21 1/8 22 3/8
20 22 23 1/2
21 23 1/4 24 1/2
22 24 1/8 25 3/4
23 25 3/8 26 3/4
24 26 3/8 27 7/8
25 27 1/2 28 7/8
26 28 1/2 30 1/8
27 29 1/2 31 1/8
28 30 5/8 32 1/4
29 31 5/8 33 1/4
30 32 3/4 34 1/4
31 33 3/4 35 1/2
32 35 36 1/2
33 36 37 5/8
34 37 1/8 38 5/8
35 38 1/8 39 7/8
36 39 1/4 40 7/8

5
FIRE DAMPERS (FD)

6 3/8"
6

W
3

Y
H

5 6
3

4
2 1

FDO Connection

6 3/8"
X = W + 2” 6
X

5
1 6

2 4
3
FDR Connection

Dimensions H and W shall be furnished approximately


5mm undersize the nominal height and width of duct

6
FIRE DAMPERS (FD)

X = Ø + 2”

FDSR Connection

Dimensions Ø shall be furnished approximately


3mm undersize the nominal diameter of duct.

FDSO Connection

Dimensions H and W shall be furnished approxi-


mately 3mm undersize the nominal height and width
of duct

7
FIRE DAMPERS (FD)

• Blade type fire damper is made of single or multi-blades.


• Frame of damper flanged type or hat-shape of galvanized steel construction
• Blades are single skin, 3-V and inter locking galvanized steel
• Optionally includes rectangular, square, circular or flat oval connections.
• The blades are mounted on self oiling bronze bushings.
• Fire dampers are fitted with 72°c ( 165° F ) fusible links [UL listed].
• Fire Damper are tested to stand 3-hours.

8
FIRE DAMPERS (FD)

Frame : Flanged built of 6”×1”×16 gauge galvanized steel.


Or Hat-Shape built of 5”×7/8”×16 gauge galvanized steel.
Blade : 3-V, built of 16 gauge galvanized steel.
Finish : mill galvanized.
Fusible link : 72°c ( 165° F ) UL listed
or thermoelectric resettable tripping device 72°c ( 165° F ).
Other temperatures available on request.
Operation : Stainless steel closure springs
Or Spring-Return Electric Actuators.
Fire rating : 3 hours.
Minimum size : 4”x 4”
Maximum size : 36”x36” as a single section. Multiple section assembly with unlim-
ited size, where each section operates independently. For detail of
multiple sections consult Rabie Al -Takyeef Factory

1. Stainless steel closure 5. Catch device 9. Linkage (Side or Face


spring. 6. Landing angle linkage)
2. Fusible link (72°C) 7. Electric actuator
3. Galvanized steel frame 8. thermoelectric tripping
4. Galvanized steel blades device

2
3

9
6

4 1

9
FIRE DAMPERS (FD)

8
7

9 4

10
FIRE DAMPERS (FD)

H + 50

W
W = Duct Width
H = Duct Height W + 50
B

A = Duct Width (W) -


5mm
B = Duct Height (H) -
5mm

11
FIRE DAMPERS (FD)

Y
H

MODEL - FDI MODEL - FDO

H
Ø
Y

MODEL - FDSR MODEL - FDSO

12
FIRE DAMPERS (FD)

 These instructions apply to 3 hour rated fire dampers (blades must be horizontal)
models FDI, mounted in concrete masonry, walls (Vertical) and concrete floors
(Horizontal).
 Fire dampers are manufactured and labeled for either vertical or horizontal installa-
tion. The dampers must be installed in accordance with the labeling. For horizontal
installation the locking ramp shall be always on top and lead blade pointing down.

FIRE DAMPER SLEEVE:


 All Fire Dampers should be installed in a Steel Sleeve with inside dimensions similar
to Fire Damper outside Dimensions. The recommended minimum Sleeve thickness
shall not be less than the duct thickness and shall as per Table 1 below.
 Fire Damper sleeve shall be fixed to the fire damper by a row of spot welds, rivets or
#10 sheet metal self drilling screws at maximum distance of 50mm (2 inch) from the
edges and at spaced middle distances of maximum 150mm (6 inch) center to center,
as per Figure 1 below.
 The fire damper sleeve shall extend by maximum 150mm (6 inch) from the wall of
floor opening in both sides. In case there is an access door incorporated with the
sleeve, it is allowed to extend by maximum 400mm (16 inch) from the access door
side. See Figures 2 and 3.

Sleeve Thickness Duct Dimension Type of Duct to


Sleeve Connection
mm inch Gauge mm inch
Permitted
2.00 - 3.50 0.075 – 0.138 14 - 10 All Dimensions Rigid or Breakaway
91 max. height 36 max. height
1.50 0.060 16 610 max. width 24 max. width Rigid or Breakaway
610 max. diameter 24 max. diameter
1.50 0.060 16 All duct sizes

1.20 0.048 18 2159 and over 85 and over

0.90 0.036 20 1397 - 2134 55 – 84


Breakaway only
0.76 0.030 22 787 - 1372 31 – 54

0.60 0.024 24 330 - 762 13 – 30

0.46 0.018 26 305 and under 12 and under

Table 1 (Minimum Sleeve Thickness)

16-14 13
FIRE DAMPERS (FD)

Wall

Clearance
Min. 6mm
Max. 50mm

Max. 150mm

Retaining angle
Attaching
FDI FDI Sleeve

FIGURE 1: Attaching Sleeve to Fire FIGURE 3: Horizontal Installation


Damper

Wall
Retaining angle
Clearance between
Sleeve and wall
Min overlap 25mm

Min clearance 6mm

FDI Sleeve

MAX. 150mm MAX. 150mm

FIGURE 2: Vertical Installation

14
FIRE DAMPERS (FD)

CLEARANCES REQUIRED BETWEEN FIRE DAMPER SLEEVES AND WALL/FLOOR


OPENINGS:

 Clearance between Fire Damper Sleeve and wall shall be minimum10mm per 1 me-
ter (1/8 inch per 1 foot) damper height and 10mm per 1 meter (1/8 inch per 1 foot)
damper width but not less than 6mm (1/4 inch) and not more than 50mm (2 inch) in
either directions. See Figures 2 and 3.

 These clearances are required to allow the expansion of fire damper and sleeve to
fire elevated high temperature.

ATTACHING FIRE DAMPER SLEEVE TO


WALL/FLOOR OPENINGS:

 Securing fire damper and sleeve to wall or


Retaining angle
floor opening shall be via retaining angles
on each side of the wall and floor. Retain-
ing angles shall be minimum 32mm ×
32mm (1.25 inch × 1.25 inch) with mini-
mum overlap with the wall or floor of
25mm (1 inch). The thickness of retaining
angles shall be of minimum 1.5mm (0.060
inch or Gauge 16). Please refer to Figure
Max. 150mm

4.

 The retaining angle should be fixed to the


fire damper sleeve by a row of spot welds,
rivets or #10 sheet metal self drilling
Sleeve
screws at maximum distance of 50mm (2
FDI
inch) from the edges and at spaced mid-
dle distances of maximum 150mm (6 inch)
center to center. The retaining angle
should not be fastened to the wall or floor FIGURE 4: Installing Sleeve to Wall/ Floor
to allow for damper expansion.

15
FIRE DAMPERS (FD)

CONNECTING DUCTS TO FIRE DAMPER SLEEVE:

 Any duct connection other than shown on Figure 5 (Breakaway Connections) are
considered as rigid connections.

 Breakaway connections shall be fixed to the sleeve by 2 pieces of #10 sheet metal
self drilling screw on each side and on the bottom located in the center of the slip
pocket and penetrating both sides of the slip pocket.

DUCT JOINTS

PLAIN "S" SLIP HEMMED "S" SLIP

DOUBLE "S" SLIP INSIDE SLIP JOINT

STANDING S STANDUNG S
(ANGLE REINFORCED)

STANDING (ALT) STANDUNG S


(BAR REINFORCED)

STANDUNG S DRIVE SLIP JOINT


(ANGLE REINFORCED)

FIGURE 5: Breakaway Duct Connecting Joints

16
COMBINATION FIRE AND
SMOKE DAMPER (FSD)

Combination fire & smoke damper are used in HVAC systems, where a fire damper and
smoke damper are required together as a single section and used to prevent spread of
fire and smoke in the building ventilation system. It is available for rectangular, square,
circular or flat oval duct fixing.

The FSD has been qualified for Fire Resistance Rating 3 Hours and Leakage Rating III
up to 10.2 m/s (2000 fpm) and 1.5 kPa (6 in. wg). FSD may be installed vertically (with
blades running horizontal) or horizontally and is rated for airflow and leakage in either di-
rection.

1
COMBINATION FIRE AND
SMOKE DAMPER (FSD)

Frame Material : Galvanized steel, Thickness 16 ga. (1.5mm)


Frame Type : 125mm x 23mm hat channel, or 150×25 Flanged
Blade Material : Galvanized steel, Thickness 16 ga. (1.5mm)
Blade Type : 3V
Linkage : Plated steel out of airstream, concealed in jamb
Axle Bearings : Bronze
Axle Material : Plated steel
Blade Seals : Silicone (optional)
Jamb Seals : Stainless Steel
Closure Device : Thermoelectric resettable tripping device
Closure Temp. : 72°C (165°F). Others on request
Minimum size : 4”x 4”
Maximum size : 36”x36” as a single section. Multiple section assembly
with unlimited size, where each section operates inde
pendently.

1. Stainless steel closure 5. Catch device 9. Linkage (Side of Face


spring. linkage)
6. Landing angle
2. Fusible link (72°C) 7. Electric actuator
3. Galvanized steel frame 8. Thermoelectric tripping
4. Galvanized steel blades device

3
6
2
7

Shaft
9

4 1
Sleeve 5
3

2
COMBINATION FIRE AND
SMOKE DAMPER (FSD)

Sleeve
3

9
7

9 8

Mounting
Plate

3
COMBINATION FIRE AND
SMOKE DAMPER (FSD)

H + 50

W
W = Duct Width
W + 50
H = Duct Height
B

A
A = Duct Width (W) - 5mm
B = Duct Height (H) - 5mm

4
SOUND ATTENUATORS (RSA)

Building design and construction must include engineering control for HVAC equipment to

limit objectionable noise levels. Meeting the acoustical expectations of building owners

and occupants has become increasingly difficult with today’s light weight construction

methods and with HVAC systems that are located in close proximity to occupied spaces

and listener critical environments.

Noise is produced in an HVAC system by various sources including fans, motors and air

moving through ductwork and fittings. The sound propagates from the ductwork into the

occupied building spaces through two means : radiated and duct born sound. Radiated

sound propagates out in all directions from the sheet metal housing of duct, fans and

fittings, this sometimes called “Breakout” sound. Duct born sound travels through duct

work and eventually enters occupied spaces through room air outlets.

RABIE Engineering Department has the practical experience using proven and tested

materials to quite mechanical systems in new design and remedial construction projects.

1
SOUND ATTENUATORS (RSA)

 Sound attenuation : The ratio of sound energy absorbed by a given surface, to the

sound energy incident upon that surface.

 Decibel (dB) : Is a logarithmic unit indicates the ratio of a physical quantity (usually

power or intensity) relative to a specified or implied reference level. The ratio may

be power, sound pressure, voltage or intensity or several other things.

 Duct born noise : Noise which is transmitted along ductwork, both upstream and

downstream of fan.

 Frequency : The number of pressure variations per second, which is measured in

cycles per second, called Hertz (Hz).

 Insertion loss : A measure of the noise reduction capability of an attenuator.

 Octave bands : Sound that contain energy over a wide range of frequencies are

divided into sections called bands. A common standard division is in 8 octave bands

identified by their center frequencies 62.5, 125, 250, 500, 1000, 2000, 4000, and

8000 Hz.

 Sound power level (SWL) : Is a logarithmic measure of the sound power in

comparison to a specified reference level.

 Sound pressure level (SPL) : In decibels, of a sound is 20 times the logarithm to the

base 10 of the sound pressure to the reference pressure. The reference pressure

shall be explicitly stated and is defined by standards.

 Reverberant : Noise which is transmitted by reflection of room surfaces.

 Reverberant time : Sound after it is ended at the source will continue to reflect of

surfaces until the sound wave loses energy by absorption to eventually die out.

2
SOUND ATTENUATORS (RSA)

Recommended NC Levels For Various Activities :-


The noise in different types of rooms should not exceed the Noise Criterion limits listed below.

Recommended NC Level Equivalent Sound Level


Type of Room - Space Type
NC Curve dBA
Residences
Apartment Houses 25-35 35-45
Assembly Halls 25-30 35-40
Churches 30-35 40-45
Courtrooms 30-40 40-50
Factories 40-65 50-75
Private Homes, rural and suburban 20-30 30-38
Private Homes, urban 25-30 34-42
Hotels/Motels
- Individual rooms or suites 25-35 35-45
- Meeting or banquet rooms 25-35 35-45
- Service and Support Areas 40-45 45-50
- Halls, corridors, lobbies 35-40 50-55
Offices
- Conference rooms 25-30 35-40
- Private 30-35 40-45
- Open-plan areas 35-40 45-50
- Business machines/computers 40-45 50-55
Hospitals and Clinics
- Private rooms 25-30 35-40
- Operating rooms 25-30 35-40
- Wards 30-35 40-45
- Laboratories 35-40 45-50
- Corridors 30-35 40-45
- Public areas 35-40 45-50
Schools
- Lecture and classrooms 25-30 35-40
- Open-plan classrooms 35-40 45-50
Movie motion picture theaters 30-35 40-45
Libraries 35-40 40-50
Legitimate theaters 20-25 30-65
Private Residences 25-35 35-45
Restaurants 40-45 50-55
TV Broadcast studies 15-25 25-35
Recording Studios 15-20 25-30
Concert and recital halls 15-20 25-30
Sport Coliseums 45-55 55-65
Sound broadcasting 15-20 25-30

3
SOUND ATTENUATORS (RSA)

Sound attenuators is used to reduce fan and machine noise to meet the required noise
levels, can be straight RSAR (Rectangular), or bend shapes RSABV (Vertical), and
RSABH (Horizontal).

 Splitters are fitted with an acoustic absorbing material has a glass tissue facing, non-
flammable, non-hygroscopic, not sustain vermin or fungus, rot proof and odorless.
 Diffusion angle to improve pressure drop.
 Bullnose Baffles to help minimize turbulence and to minimize air pressure loss and
regenerated noise.
 Minimum 20 gauge galvanized steel for casing.
 22 gauge perforated galvanized for splitters.
 End connection of Duct Mate Flange or M.S steel angle secured to casing end.
 Components are also available in stainless steel or aluminum construction.
 Rabie attenuators are normally supplied in sections when any dimensions are ex-
ceeded.
W+70
W+40 ø12m

H+40

H+70
 50mm ≤ S ≤ 200mm
H

 100mm ≤ D ≤ 200mm

D/2 S D
W

4
SOUND ATTENUATORS (RSA)

H+70 W+70
H+40 W+40

H+40
H+70
H
W+40
W+70

W
S

D/2 S D
W
D/2

H
L2
H
m

m
W

L
L1
L1

L
H

m
m

L2
W

 50mm ≤ S ≤ 200mm
 100mm ≤ D ≤ 200mm
 m = 150mm minimum

5
SOUND ATTENUATORS (RSA)

Splitters are fitted with an acoustic absorbing material and


tested to the following tests

1. Acoustic performance ASTM C 1071 - ASTM C432-77

2. Fire resistant NFPA 90A

3. Surface burning characteristics UL 723-ASTM E84

4. Moisture absorption ASTM D-07 B-ASTM C550

5. Mold growth ASTM D2020-UL 181

Both splitters’ sides are from perforated sheet to protect


and prevent fiber erosion up to 40 m/s airway velocity.

L
B

ABSORBER

6
SOUND ATTENUATORS (RSA)

Standard Cylindrical attenuators, Types RSACD and RSACP are available in a wide
range of sizes in two standard lengths for Both “on-fan and in-duct” applications. Alterna-
tive metric and imperial sizes and acoustic lengths are available.

Type RSACD is a “straight through” design offering good acoustic performance and negli-
gible pressure loss. For higher performance, type RSACP incorporates an aerodynami-
cally efficient concentric acoustic pod.

TYPE RSACD TYPE RSACP

*Mø L *Mø L
Duct ø Duct ø

Holes Holes

Pcd Pcd

* Mø = Duct ø +200

7
SOUND ATTENUATORS (RSA)

RSA Cross Talk type attenuators have been designed to avoid noise interference be-
tween interconnected rooms. Air flow is permitted whilst noise transfer is limited.
Type RSACL, RSACU, RSACZ are used as air transfer attenuators between adjoining
area where the acoustic integrity of a common partition or ceiling needs to be maintained.

100mm
S

L1
H

ATTENUATOR TYPE RSACS


W *L2

100mm
S
H

L1
G

ATTENUATOR TYPE RSACL

W *L2

100mm
S
H

L1
G
H

ATTENUATOR TYPE RSACU

 Min. L2 = H + 150 mm
 100mm ≤ S ≤ 200mm

8
SOUND ATTENUATORS (RSA)

RABIE offers the design and engineering assistance to integrate our line of sound attenu-
ators into a system solution.

Several pieces of information are required for RABIE Noise control department to perform
an analysis on an equipment installation. These information are Project related as well as
Equipment related such as:

 Project Name

 Building Name

 Unit Code (or Tag Number)

 Complete HVAC Duct drawing with grills & diffusers sizes and air flows.

 Height between ceiling and finish floor level of the room.

 Noise Criteria required (NC Level).

 Sound Power Level (SWL) of the units in octave band center frequency (sound
spectrum). Sound Pressure Level (SPL) is not acceptable.

 Maximum allowed pressure drop across sound attenuator.

RABIE ENGINEERING DEPARTMENT WILL ASSIST ALL CUSTOMERS IN


CALCULATION AND SELECTION TO PROVIDE ATTENUATORS AT ACTUAL
JOB CONDITIONS.

9
SOUND ATTENUATORS (RSA)

Procedure of Selecting Sound Attenuator

In order to select the appropriate sound attenuator, one should first analyze the sounds
reaching the listener from the Noise source (in this case it is the AHU).

There are two types of sound reach the listener; Direct Path(s) sound and Reverberant
Path(s) sounds.

In Rabie Al-Takyeef Factory (RTF) analysis sheet, we first analyze the noise coming to
the closest and most critical room from the AHU as following:
 We fill in the AHU’s flow, which is passing the Sound Attenuator.
 We also fill in the AHU Sound Power Level (SWL) at each octave band frequency.
 We calculate how much attenuation the duct and elbows will affect on the SWL.
 And we calculate how much attenuation will develop due to End Reflection.
 By subtracting all the attenuations calculated from the system components from the
noise of the AHU we get the Sound Power leaving the system from that critical air
outlet.
 Then we calculate the Sound Pressure Level (SPL) reaching the listener from the
direct path by considering the following:
 The portion of airflow coming out from that outlet
 The distance between the air outlet and the ear of the listener
 And then we add the correction of outlet directivity
 Then we calculate the reverberant SPL reaching the listener by considering:
 The total air flow reaching the room from all outlets
 The room volume correction
 And the reverberant time correction (which is due to room acoustic construction
and contents such as furniture, curtains, wall material and surface and so on)
 By adding the direct and reverberant SPL (logarithmic addition), we get the result-
ant SPL at the listener WITHOUT sound attenuator.
 Then we consider the required or recommended NC level and add a safety factor,
then we calculate how much attenuation is required at each octave band frequency.

After the analysis is finished, we select different sizes and lengths of the sound attenua-
tor to compensate for the attenuation required, taking into account a suitable pressure
drop.

10
SOUND ATTENUATORS (RSA)

11
SOUND ATTENUATORS (RSA)

 Single Unit:
• Single Units come usually of dimension up to 2m wide and 1.2m height.
• Typical connections to ducts for single units is Slide on flange (Duct Mate flange) using screws
and sealing tape.
• Connection for great sizes but as a single unit incorporates welded angular frame of 50×50mm.
 Multiple Units:
• A sound attenuator of bigger dimensions than 2m×1.2m may come as a multiple unit that can be
joined together at site.
• Typical connection to ducts for Multiple Units is welded angular frame 50×50mm using screws
and sealing tape or gasket.
• Typical interconnections of units in a multiple unit sound attenuator is also an angular frame
50×5mm as appropriate.
• Draw bands and track welds maybe necessary to hold the overall bank stable and in position.
• Take special care to seal between the edges of each unit to prevent air from passing between the
units.
• Nose clips or sheet metal screws with a caulk or sealant is common solution in this area.
 Attenuators have no moving parts. Only general cleaning is required periodically, normally done
when the duct itself is inspected and cleaned.
 Wiping the interior wall of the units with a damp cloth will generally remove any dust and dirt build-up.
Minimal amount of water can be used to remove heavy soil, but saturating the insulation is not rec-
ommended.
 To avoid an over proportional pressure drop and unstable air-regenerated noise, horizontal installa-
tion is recommended.
 Recommended inlet distance from duct branch is 1.5 times the height, and from duct bend is 2.5
times the width.

12
VARIABLE AIR VOLUME (RAV)

RABIE VAV terminal boxes type RAV were developed for the control of air flow,
especially in variable volume systems.
They come in different models:
• RAVBS Single Duct Terminal Box - (VAV or CAV)
• RAVBP By-Pass Terminal Box

Factory fitted control package, ensures the most accurate setup of required flow rates.
The flow rate control is a closed circuit system with external power supply. RAV boxes
can be supplied with control components from any reputable manufacturer to suit the
project specification.

RAV contains a differential pressure sensor for air flow measurement (not for Bypass
type), a control damper and an integral sound attenuator for reducing the air regenerated
noise.

The control damper blade with seal insures best air tightness when closed.

RAV has a circular spigot connection up to 200 mm (8”) size, oval connection for larger
sizes on the fan side (high pressure end) and a rectangular flange connection on the
room side (low pressure end).

RTF Reserves The Right of Alternation

1
VARIABLE AIR VOLUME (RAV)

RTF Reserves The Right of Alternation

2
VARIABLE AIR VOLUME (RAV)

Room temperature controller Supply/extract air tracking control


In VAV systems, the room temperature In individual rooms and closed-off office
control takes the form of a cascade control. areas, where the balance between supply
The primary controlled variable is the room and extract air flow rate has to be
temperature. The output signal of the room maintained. Otherwise, annoying whistling
temperature controller is fed directly to the noises can occur at door gaps, and the
control damper’s actuator. doors can be difficult to open. For this
The flow rate control also generates reason, the extract air should also have
minimum and maximum limits for the air variable control in a VAV system.
flow which has benefits in keeping the room The actual value of the supply air is fed as
temperature constant and for the an input signal to the extract air controller
functioning of the overall room air (slave controller). In this way, the extract air
conditioning system. flow rate automatically follows the supply air
flow rate, even in the case where this has
Flow rate measurement
not reached its set point value.
A sensor is necessary for the positive
measurement of air flows, this is achieved Bypass VAV - Pressure Dependent
by pressure measurement at several points Bypass VAV is usually installed in a
distributed over the cross-section and pressure dependent system (application),
provision of the resulting average value. where there is no variable speed control of
The differential pressure sensor is an the supply fan, and back pressure should
optimum solution in terms of economy and be avoided. For this reason a bypass VAV
product technology. requires a pressure relief damper (or
This sensor delivers exact results for most bypass damper) to avoid exceeding the
room air conditioning applications based on maximum pressure of the system. Flow
measurement is not possible for bypass
normal upstream flow conditions.
type and so the bypass VAV comes without
Volume flow control flow sensor. The control of Bypass VAV
The control of the flow rate takes place in a shall be directly from the setpoint of the
closed control circuit, i.e. measurement – room temperature controller or BMS.
comparison – control. Pressure Independent CAV Operation
A pressure transducer converts the CAV operation is principally the same as
pressure differential into an electrical signal, VAV Terminal Boxes but the concept of
which is interpreted as the actual value by function is different. The CAV is intended to
the controller. In most applications, the set keep preset constant air volume entering
point value comes from a room temperature the duct branch downstream of the box. To
controller. do so, the compact controller will receive a
signal of the preset volume flow required
The controller compares the actual value and the actuator will act to keep the flow
with the set point value and from the constant depending on differential pressure
difference between these two alters the measurement taken (corresponding to air
control signal to the damper actuator. speed).

RTF Reserves The Right of Alternation

3
VARIABLE AIR VOLUME (RAV)

• Casing of galvanized steel sheet (gauge 22)


• Lining in the sound attenuator section of 25mm thickness
• Control damper blade of galvanized sheet steel of Gauge 16 with suitable seal
• Sensor tubes of aluminum with plastic pipes to the actuator
• Nylon Bushing
• Controller fitted to the control damper made by Belimo or Siemens. Optionally we
can use any other controller if requested
• Flow rate range is 1:10 (according to selected controller accuracy)
• Flow range is setup and programmed in the factory as required by end-user, based
on data extracted from the calibration test rig
• An optional Air Heater can be supplied with RAV on request

1) Control Blade 5) Inlet Spigot


2) Controller 6) Acoustic Liner
3) Differential Pressure Sensor 7) DP Sensor plastic hoses
4) VAV Main Casing Box

RTF Reserves The Right of Alternation

4
VARIABLE AIR VOLUME (RAV)

20

Dy
G
Dx
F

Side View Front View

Top View Rear View

Nominal Size Inlet Dx Dy A F G L Outlet Size (mm)


D Shape (mm) (mm) (mm) (mm) (mm) (mm) W H
125 mm 5 inch Round 127 127 150 300 250 600 250 200
150 mm 6 inch Round 152 152 150 300 250 600 250 200
175 mm 7 inch Round 178 178 150 300 300 700 250 250
200 mm 8 inch Round 203 203 150 300 300 700 250 250
225 mm 9 inch Flat Oval 240 203 150 350 300 700 300 250
250 mm 10 inch Flat Oval 280 203 150 400 300 700 350 250
300 mm 12 inch Flat Oval 360 203 150 500 300 700 450 250
350 mm 14 inch Flat Oval 410 258 150 550 350 800 500 300
400 mm 16 inch Flat Oval 490 258 150 650 350 800 600 300
450 mm 18 inch Flat Oval 540 305 200 700 400 900 650 350
500 mm 20 inch Flat Oval 620 305 200 850 400 900 800 350
550 mm 22 inch Flat Oval 670 356 200 850 450 1000 800 400
600 mm 24 inch Flat Oval 750 356 200 1000 450 1000 950 400

RTF Reserves The Right of Alternation

5
VARIABLE AIR VOLUME (RAV)

• Casing in galvanized steel sheet (gauge 22)


• Lining in the sound attenuator section of 25mm thickness
• Control damper blade in galvanized sheet steel of gauge 16 with suitable seal
• Nylon Bushing
• Actuator fitted to the control damper made by Belimo or Siemens. Optionally we
can use any other controller if requested
• An optional Air Heater can be supplied with RAV on request

1) Control Blade 3.1) Bypass Casing Box (only for bypass


model RAVBP)
1.1) Bypass Blade (only for bypass model
RAVBP) 4) Inlet Spigot
2) Controller 5) Acoustic Liner
3) VAV Main Casing Box

RTF Reserves The Right of Alternation

6
VARIABLE AIR VOLUME (RAV)

20

100
Dy

G
Dx
F

Side View Front View

Rear View

Top View

Nominal Size Inlet Dx Dy A F G L Outlet Size (mm)


D Shape (mm) (mm) (mm) (mm) (mm) (mm) W H
125 mm 5 inch Round 127 127 150 300 250 600 250 200
150 mm 6 inch Round 152 152 150 300 250 600 250 200
175 mm 7 inch Round 178 178 150 300 300 700 250 250
200 mm 8 inch Round 203 203 150 300 300 700 250 250
225 mm 9 inch Flat Oval 240 203 150 350 300 700 300 250
250 mm 10 inch Flat Oval 280 203 150 400 300 700 350 250
300 mm 12 inch Flat Oval 360 203 150 500 300 700 450 250
350 mm 14 inch Flat Oval 410 258 150 550 350 800 500 300
400 mm 16 inch Flat Oval 490 258 150 650 350 800 600 300
450 mm 18 inch Flat Oval 540 305 200 700 400 900 650 350
500 mm 20 inch Flat Oval 620 305 200 850 400 900 800 350
550 mm 22 inch Flat Oval 670 356 200 850 450 1000 800 400
600 mm 24 inch Flat Oval 750 356 200 1000 450 1000 950 400

RTF Reserves The Right of Alternation

7
VARIABLE AIR VOLUME (RAV)

Volumetric Flow Range and minimum differential pressure for each size
For Types RAVBS and RAVBP (fully Open)
Volumetric Flow Rate Minimum Differential Pressure (Pa)
Nominal Size
D l/s m³/hr CFM Static Dynamic Total
30 110 65 20 3 23
60 220 125 20 6 26
125 mm 5 inch
120 430 255 35 24 59
250 900 530 55 106 161
45 160 95 20 3 23
100 360 210 20 17 37
150 mm 6 inch
190 680 405 30 61 91
350 1260 740 50 207 257
60 220 125 20 3 23
130 470 275 20 15 35
175 mm 7 inch
260 940 550 35 60 95
450 1620 955 50 180 230
80 290 170 20 3 23
170 610 360 20 13 33
200 mm 8 inch
330 1190 700 20 50 70
650 2340 1375 40 193 233
105 380 220 20 3 23
220 790 465 20 12 32
225 mm 9 inch
425 1530 900 30 44 74
900 3240 1905 45 198 243
130 470 275 20 3 23
260 940 550 20 10 30
250 mm 10 inch
520 1870 1100 30 40 70
1150 4140 2435 35 197 232
185 670 390 20 2 22
390 1400 825 20 11 31
300 mm 12 inch
775 2790 1640 25 42 67
1600 5760 3390 35 181 216
255 920 540 20 2 22
500 1800 1060 20 9 29
350 mm 14 inch
990 3560 2100 20 34 54
2200 7920 4660 30 167 197

Doted Range is not recommended due to high pressure drop and noise

RTF Reserves The Right of Alternation

8
VARIABLE AIR VOLUME (RAV)

Volumetric Flow Range and minimum differential pressure for each size
For Types RAVBS and RAVBP (fully Open)

Volumetric Flow Rate Minimum Differential Pressure (Pa)


Nominal Size
D l/s m³/hr CFM Static Dynamic Total
320 1150 680 20 2 22
670 2410 1420 20 9 29
400 mm 16 inch
1330 4790 2820 20 36 56
2750 9900 5825 30 155 185
415 1490 880 20 2 22
830 2990 1760 20 8 28
450 mm 18 inch
1650 5940 3495 20 32 52
3600 12960 7630 20 152 172
530 1910 1125 20 2 22
1050 3780 2225 20 7 27
500 mm 20 inch
2100 7560 4450 20 29 49
4600 16560 9745 20 139 159
610 2200 1295 20 2 22
1250 4500 2650 20 8 28
550 mm 22 inch
2500 9000 5295 20 31 51
5250 18900 11125 20 135 155
745 2680 1580 20 2 22
1500 5400 3180 20 7 27
600 mm 24 inch
3000 10800 6355 20 28 48
6450 23220 13665 20 127 147

Doted Range is not recommended due to high pressure drop and noise

RTF Reserves The Right of Alternation

9
VARIABLE AIR VOLUME (RAV)

Discharge Sound Power Level


For Types RAVBS and RAVBP (fully Open)

Volumetric Discharge Sound Power Level Discharge Sound Power Level Discharge Sound Power Level
Nominal Flow Rate (dB) at ΔPst=100Pa (dB) at ΔPst=200Pa (dB) at ΔPst=500Pa
Size
D
1000
2000
4000

1000
2000
4000

1000
2000
4000
dBA

dBA

dBA
125
250
500

125
250
500

125
250
500
NC

NC

NC
l/s CFM

30 65 45 31 27 16 19 15 6 <20 39 38 35 24 27 25 2 <20 48 47 45 34 37 34 11 <20

125 5 60 125 50 36 32 21 24 20 11 <20 44 43 40 29 32 30 7 <20 53 52 50 39 42 39 16 <20


mm inch 120 255 55 46 45 26 26 22 17 <20 56 53 48 34 34 32 19 <20 65 62 58 44 44 41 28 21
250 530 62 56 50 35 34 24 24 <20 66 63 58 43 42 34 29 22 75 72 68 53 52 43 38 33
45 95 47 33 35 19 21 17 8 <20 41 40 37 27 29 27 4 <20 50 49 47 37 39 36 13 <20

150 6 100 210 50 37 40 22 24 20 11 <20 46 44 40 30 32 30 9 <20 55 53 50 40 42 39 18 <20


mm inch 190 405 55 53 47 33 31 24 18 <20 63 60 55 41 39 34 26 <20 72 69 65 51 49 43 35 30
350 740 61 61 56 41 40 29 25 <20 71 68 64 49 48 39 34 29 73 70 66 53 50 44 36 31
60 125 43 34 30 21 23 18 5 <20 42 41 38 29 31 28 6 <20 51 50 48 39 41 37 15 <20

175 7 130 275 48 38 47 33 31 24 10 <20 46 45 58 45 41 37 13 <20 55 54 73 60 54 48 27 <20


mm inch 260 550 51 40 48 34 32 31 13 <20 48 47 59 46 42 47 15 <20 57 56 74 61 55 60 28 <20
450 955 55 55 51 35 34 32 19 <20 51 64 62 47 44 48 26 <20 60 76 77 62 57 61 38 27
80 170 51 34 31 21 23 18 12 <20 42 41 39 29 31 28 6 <20 51 50 49 39 41 37 15 <20

200 8 170 360 53 45 51 38 36 35 15 <20 43 54 64 52 48 53 20 <20 52 65 80 69 63 69 34 <20


mm inch 330 700 60 54 56 40 38 36 22 <20 48 64 70 54 50 54 27 <20 58 77 87 71 65 70 42 29
650 1375 65 62 61 48 45 42 28 21 52 73 76 64 59 63 35 23 62 79 87 84 76 81 44 31
105 220 51 34 35 25 26 21 12 <20 44 43 41 33 34 31 8 <20 53 52 51 43 44 40 17 <20

225 9 220 465 52 45 52 40 38 35 14 <20 44 57 61 52 49 51 20 <20 53 68 75 67 63 65 32 <20


mm inch 425 900 59 51 57 45 42 39 21 <20 49 64 66 58 54 56 26 <20 59 70 81 74 69 71 36 22
900 1905 62 60 61 52 50 45 25 <20 51 75 70 67 64 64 36 25 70 70 82 75 70 72 38 28
130 275 51 36 32 25 26 21 12 <20 44 43 40 33 34 31 8 <20 53 52 50 43 44 40 17 <20

250 10 260 550 53 45 54 45 44 42 15 <20 45 53 67 59 57 62 23 <20 54 64 83 77 73 80 39 20


mm inch 520 1100 58 52 56 50 47 43 20 <20 49 61 69 65 60 63 26 <20 58 73 85 84 76 81 41 26
1150 2435 64 61 63 55 52 50 27 20 54 71 77 71 66 73 35 21 63 84 89 91 83 93 51 37
185 390 53 39 34 27 28 23 14 <20 49 46 42 35 36 33 12 <20 58 55 52 45 46 42 21 <20

300 12 390 825 58 49 50 42 40 38 20 <20 54 57 61 54 51 54 21 <20 63 68 75 69 65 68 33 21


mm inch 775 1640 61 57 52 50 50 49 24 <20 56 66 63 64 63 69 29 <20 65 78 77 81 80 86 43 30
1600 3390 65 63 58 55 51 50 28 21 59 72 70 70 64 70 34 22 68 85 85 88 81 87 48 38
255 540 51 53 35 28 29 24 16 <20 51 48 43 36 37 34 14 <20 60 57 53 46 47 43 23 <20
500 1060 58 59 50 40 40 39 23 <20 58 52 61 51 51 54 21 <20 68 61 75 65 64 68 33 25
350 14
mm inch 990 2100 63 66 54 50 48 45 29 20 63 58 65 63 61 62 27 <20 73 68 79 80 76 78 38 31

2200 4660 68 73 63 60 55 53 35 27 68 64 75 75 69 73 34 25 78 75 91 95 85 91 49 38

RTF Reserves The Right of Alternation

10
VARIABLE AIR VOLUME (RAV)

Discharge Sound Power Level


For Types RAVBS and RAVBP (fully Open)

Volumetric Discharge Sound Power Lev- Discharge Sound Power Lev- Discharge Sound Power Lev-
Flow Rate el (dB) at ΔPst=100Pa el (dB) at ΔPst=200Pa el (dB) at ΔPst=500Pa
Nominal Size
D
1000
2000
4000

1000
2000
4000

1000
2000
4000
dBA

dBA

dBA
125
250
500

125
250
500

125
250
500
NC

NC

NC
l/s CFM

320 680 51 52 35 29 30 25 16 <20 55 50 43 37 38 35 17 <20 64 59 53 47 48 44 26 20

400 16 670 1420 58 57 50 42 41 39 22 <20 62 54 61 53 51 54 24 <20 72 63 75 67 64 67 35 30


mm inch 1330 2820 64 65 60 51 50 46 29 21 68 61 73 64 62 63 32 25 78 71 76 69 65 68 40 37

2750 5825 70 72 66 61 60 55 35 28 74 67 80 76 74 75 38 32 79 75 77 72 70 72 42 38

415 880 53 53 34 36 33 29 17 <20 57 50 42 44 41 39 19 <20 66 59 52 54 51 48 28 22

450 18 830 1760 58 59 53 43 42 41 23 <20 62 56 65 52 52 55 25 <20 71 66 74 65 64 63 34 29


mm inch 1650 3495 67 65 61 53 51 50 30 24 71 61 74 64 63 67 34 28 72 67 74 65 65 62 35 30

3600 7630 75 74 70 62 61 60 39 34 79 69 84 74 75 80 43 38 73 66 72 66 67 62 35 31

530 1125 56 53 35 36 33 29 19 <20 59 51 43 44 41 39 21 <20 68 60 53 54 51 48 30 25

500 20 1050 2225 64 60 51 46 45 44 26 20 67 57 62 56 55 59 29 23 77 67 76 68 68 72 39 36


mm inch 2100 4450 71 68 61 55 53 52 34 29 74 64 74 66 64 69 36 32 79 75 80 80 79 84 44 38

4600 9745 75 75 70 65 64 63 39 34 78 70 84 78 77 83 43 37 83 82 82 81 80 82 47 43

610 1295 63 56 36 38 36 30 25 <20 61 52 44 46 44 40 22 <20 70 61 54 56 54 49 31 27

550 22 1250 2650 66 62 51 46 45 45 28 22 63 57 62 55 54 59 26 <20 72 66 76 66 66 72 36 30


mm inch 2500 5295 76 69 62 56 54 53 38 34 72 63 75 66 64 69 35 30 82 72 91 79 78 84 47 42

5250 11125 79 75 70 64 62 61 42 38 74 68 84 75 73 79 41 33 84 77 95 82 80 80 50 45
745 1580 64 59 37 38 36 30 26 20 62 53 45 46 44 40 23 <20 71 62 55 56 54 49 32 28

600 24 1500 3180 68 64 59 45 43 42 31 25 65 57 71 54 52 55 29 21 74 66 86 65 63 67 41 33


mm inch 3000 6355 75 71 68 56 53 52 38 33 71 63 81 67 64 68 37 29 80 72 98 80 77 82 52 41

6450 13665 78 73 73 65 63 61 40 37 73 64 86 77 76 79 41 32 82 73 98 85 80 80 52 43

Notes:
ΔPst Static Differential Pressure
Performance Ratings of Air Terminals are in accordance with standards AHRI 880-2008 and ASHRAE 130-2008
Sound Level measurements are in accordance with standard ISO 3741 comparison method
Noise Criteria and dB (A) calculations are based on Standard AHRI 885-2008 (See page 14)

RTF Reserves The Right of Alternation

11
VARIABLE AIR VOLUME (RAV)

Case-Radiated Sound Power Level


For Types RAVBS and RAVBP (fully Open)

Volumetric Radiated Sound Power Level Radiated Sound Power Level Radiated Sound Power Level
Nominal Flow Rate (dB) at ΔPst=100Pa (dB) at ΔPst=200Pa (dB) at ΔPst=500Pa
Size
D 1000
2000
4000

1000
2000
4000

1000
2000
4000
dBA

dBA

dBA
125
250
500

125
250
500

125
250
500
NC

NC

NC
l/s CFM

30 65 28 26 26 26 17 15 3 <20 31 27 26 27 20 15 4 <20 35 28 27 28 25 24 6 <20

125 5 60 125 40 33 26 21 17 15 5 <20 42 35 30 27 23 16 8 <20 46 40 37 34 31 27 14 <20


mm inch 120 255 45 39 31 25 22 16 10 <20 46 40 33 29 26 21 12 <20 50 43 40 36 33 29 17 <20
250 530 46 43 37 29 27 18 13 <20 49 45 40 34 31 25 16 <20 54 46 43 38 34 32 20 <20
45 95 28 23 25 21 15 15 0 <20 28 25 26 24 18 15 2 <20 33 28 28 29 28 24 7 <20

150 6 100 210 40 35 27 21 19 15 6 <20 42 37 31 27 25 19 9 <20 46 41 38 35 32 28 15 <20


mm inch 190 405 42 40 31 23 23 16 9 <20 45 42 35 29 28 23 12 <20 50 46 42 37 35 32 19 <20
350 740 46 46 38 31 27 22 15 <20 49 48 42 35 32 28 18 <20 54 51 47 40 36 35 23 <20
60 125 30 26 27 21 17 15 1 <20 30 28 28 25 20 17 3 <20 34 31 32 31 29 25 9 <20

175 7 130 275 41 36 27 22 20 20 6 <20 43 39 32 28 26 23 10 <20 47 44 40 36 33 30 16 <20


mm inch 260 550 43 42 31 24 24 21 10 <20 46 44 36 30 29 26 14 <20 51 48 43 38 36 34 20 <20
450 955 48 49 41 32 30 26 17 <20 51 51 44 37 34 32 20 <20 55 53 49 42 38 38 24 <20
80 170 32 29 28 20 18 15 3 <20 32 30 29 25 21 18 5 <20 34 34 36 33 30 26 12 <20

200 8 170 360 41 37 27 22 21 25 7 <20 44 41 33 29 27 27 12 <20 48 46 42 37 34 32 18 <20


mm inch 330 700 44 43 30 25 25 26 11 <20 47 46 36 31 30 28 15 <20 52 50 44 39 37 35 21 <20
650 1375 50 51 43 33 32 30 20 <20 53 53 46 38 36 35 23 <20 56 54 51 43 40 40 26 <20
105 220 32 29 27 22 17 15 2 <20 33 31 30 26 21 17 5 <20 35 35 35 33 31 26 11 <20

225 9 220 465 42 36 27 21 20 20 6 <20 45 41 33 29 27 24 11 <20 50 47 42 37 35 32 18 <20


mm inch 425 900 46 40 30 23 24 23 10 <20 49 45 37 31 30 28 15 <20 54 51 44 39 38 36 22 <20
900 1905 50 49 42 31 32 28 18 <20 54 52 46 37 36 34 22 <20 58 55 51 43 40 40 26 <20
130 275 31 29 26 23 15 15 2 <20 33 32 30 27 21 15 6 <20 36 35 34 33 31 26 11 <20

250 10 260 550 42 35 26 20 19 15 6 <20 46 40 33 29 26 21 12 <20 51 47 42 37 35 32 19 <20


mm inch 520 1100 47 37 29 21 23 19 10 <20 51 44 37 31 30 27 16 <20 56 51 44 39 38 36 22 <20
1150 2435 50 47 41 28 32 26 17 <20 54 51 45 35 36 32 21 <20 59 55 50 42 40 40 26 <20
185 390 36 27 25 22 15 15 2 <20 36 31 29 26 20 15 5 <20 38 38 37 34 32 28 13 <20

300 12 390 825 42 36 27 21 20 15 7 <20 46 42 34 29 27 24 12 <20 53 50 45 40 38 36 22 <20


mm inch 775 1640 47 42 37 26 28 21 13 <20 51 47 42 33 33 29 18 <20 58 55 48 42 41 40 26 <20
1600 3390 51 49 39 30 35 29 18 <20 55 53 44 36 39 35 22 <20 62 57 51 43 42 43 28 <20
255 540 37 30 27 24 18 15 4 <20 38 34 31 28 23 17 7 <20 40 40 38 36 34 30 15 <20

350 14 500 1060 42 37 27 23 23 17 7 <20 47 43 35 31 30 26 13 <20 55 53 46 41 39 38 23 <20


mm inch 990 2100 46 41 33 26 30 22 12 <20 52 47 41 34 35 31 18 <20 59 55 48 42 42 42 26 <20
2200 4660 56 51 42 31 37 31 21 <20 59 54 46 37 40 36 24 <20 63 58 51 43 43 45 29 <20

RTF Reserves The Right of Alternation

12
VARIABLE AIR VOLUME (RAV)

Case-Radiated Sound Power Level


For Types RAVBS and RAVBP (fully Open)

Volumetric Radiated Sound Power Level Radiated Sound Power Level Radiated Sound Power Level
Nominal Flow Rate (dB) at ΔPst=100Pa (dB) at ΔPst=200Pa (dB) at ΔPst=500Pa
Size 1000
2000
4000

1000
2000
4000

1000
2000
4000
dBA

dBA

dBA
D
125
250
500

125
250
500

125
250
500
NC

NC

NC
l/s CFM

320 680 38 32 28 25 20 15 5 <20 40 36 33 30 26 19 9 <20 42 42 39 37 36 32 16 <20

670 1420 42 37 26 24 25 18 8 <20 47 43 35 32 32 27 14 <20 56 55 47 41 40 40 25 <20


400 16
mm inch 1330 2820 45 39 29 26 31 23 11 <20 52 47 39 34 37 32 18 <20 59 55 48 42 42 43 26 <20

2750 5825 60 52 44 32 38 32 24 <20 62 55 48 37 41 37 27 <20 63 58 51 42 44 46 29 <20

415 880 39 35 30 27 23 15 7 <20 42 39 35 32 29 21 12 <20 44 44 40 39 38 34 18 <20

830 1760 42 38 26 26 28 20 8 <20 48 44 36 34 35 29 15 <20 58 58 48 42 41 42 26 <20


450 18
mm inch 1650 3495 44 38 25 26 33 24 10 <20 53 47 38 35 39 34 19 <20 60 55 48 42 43 45 26 <20

3600 7630 65 54 47 33 40 34 27 20 66 56 50 38 42 38 29 22 64 59 51 42 45 48 30 20

530 1125 40 37 31 28 25 15 8 <20 44 41 37 34 32 23 14 <20 46 46 41 40 40 36 20 <20

1050 2225 42 38 25 27 30 21 9 <20 48 44 36 35 37 30 16 <20 59 60 49 42 42 44 28 <20


500 20
mm inch
2100 4450 43 36 21 26 34 25 11 <20 53 47 36 35 41 35 20 <20 60 55 48 42 43 46 27 <20

4600 9745 69 55 49 34 41 35 31 26 69 57 52 38 43 39 32 26 64 59 51 41 46 49 30 20

610 1295 41 40 33 30 28 15 10 <20 46 44 39 36 35 25 16 <20 48 48 42 42 42 38 21 <20

1250 2650 42 39 25 29 33 23 10 <20 49 45 37 37 40 32 18 <20 61 63 50 43 43 46 30 <20


550 22
mm inch
2500 5295 42 35 17 26 36 26 11 <20 54 47 35 36 43 37 21 <20 61 55 48 42 44 48 27 <20

5250 11125 74 57 52 35 43 37 35 31 73 58 54 39 44 40 35 30 65 60 51 41 47 51 31 21

745 1580 42 42 34 31 30 15 12 <20 48 46 41 38 38 27 18 <20 50 50 43 43 44 40 23 <20

1500 3180 42 39 24 30 35 24 12 <20 49 45 37 38 42 33 19 <20 62 65 51 43 44 48 32 21


600 24
mm inch
3000 6355 41 33 13 26 37 27 12 <20 54 47 33 36 45 38 22 <20 61 55 48 42 44 49 28 <20

6450 13665 75 58 54 36 44 38 37 33 75 59 56 39 45 41 37 33 65 60 51 40 48 52 31 22

RTF Reserves The Right of Alternation

13
VARIABLE AIR VOLUME (RAV)

NC levels of the different VAV boxes model RAV are calculated based on AHRI 885-2008
standard and under the following application assumptions:
• Octave bands 2, 3, 4, 5, 6 & 7 only are considered in the acoustical module.
• The VAV installation layout is as per Figure 1.
• The VAV distribute air into two branches.
• Critical paths of sound taken into consideration are Radiated Sound and Discharged
Sound.

Figure 1: VAV installation layout

RTF Reserves The Right of Alternation

14
VARIABLE AIR VOLUME (RAV)

Discharge Sound Attenuation Factors table:

Octave Band Frequency, Hz


Sound Attenuation (Insertion Loss)
calculated as per AHRI 885-2008 125 250 500 1000 2000 4000
Environmental Effect 2 1 0 0 0 0
Lined (1" liner) Straight Duct size 300×600, 1.5m 2 3 9 18 16 12
Lined Duct Tee (1" liner) size 300mm 1 6 6 11 10 10
Lined (1" liner) Straight Duct size 300×300, 0.9m 1 2 6 12 12 8
Branch power division (2 branches) 3 3 3 3 3 3
Lined Flexible Duct 300mm, 0.9m 2 6 12 9 11 4
End reflection factor (300mm) 7 3 1 0 0 0
Space Effect (listener at 1.5m in a 60m³ room) 5 6 7 7 8 9
Total Discharge attenuation 23 30 44 60 60 46

Radiated Sound Attenuation Factors table:

Octave Band Frequency, Hz


Sound Attenuation (Insertion Loss)
calculated as per AHRI 885-2008 125 250 500 1000 2000 4000
Environmental Effect 2 1 0 0 0 0
Solid Gypsum board Ceiling Tiles attenuation 21 25 25 27 27 28
Total Radiated attenuation 23 26 25 27 27 28

RTF Reserves The Right of Alternation

15
VARIABLE AIR VOLUME (RAV)

16
ELECTRIC AIR HEATER (REH)

RABIE Electric Air Heaters type REH have been developed to reheat air in ventilation
systems. The air heaters are suitable for installation in circular (REH-C) or rectangular &
square (REH-R) ducts.
The heater units are custom sized to fit any duct or to be built-in a terminal unit.
Casing and control box are made from heavy galvanized steel sheet as standard and
optionally can be made from aluminum or stainless steel. Heating elements are made
either from stainless tubes or high grade resistance wire.

Control Panel: On/Off Control


Enclosure Type the control panel of an ON/OFF electric
IP10 (NEMA 1) enclosures constructed for heater, whether single or multiple stages,
indoor use to provide a degree of includes the following components:
protection to personnel against incidental • Overload / short circuit protection
contact with the enclosed equipment and device
to provide a degree of protection against • Transformer and control fuse
falling dirt
• Automatic reset thermal cut-out
Control Principle: • Manual reset thermal cut-out
The heater can be operated as stand- • Airflow switch
alone control or to be compatible with
BMS. Controller should operate it as ON/ • Contactor (s)
OFF or modulating control. • Room thermostat (optional)
• Pilot light (optional)
• Disconnect switch (optional)
Design & Performance Data are subject to change without prior notice.

1
ELECTRIC AIR HEATER (REH)

(Continued from page 1)

Proportional Control (Modulating)


The control panel of a proportional electric heater includes the following components:
• Overload / short circuit protection device
• Transformer and control fuse
• Automatic reset thermal cut-out
• Manual reset thermal cut-out
• Airflow switch
• Contactor (s)
• Room thermostat
• PWM control
• Disconnect switch (optional)
Mechanical Construction:
Slip In Type
The slip-in type electric heaters are designed so
that the entire frame can be inserted into the duct.
Advantages of slip-in electric heaters:
A system using a slip-in heater permits the
installation of the entire ventilation duct system
before the heaters become available.
Retrofits are much simpler, smaller dimension slip
-in heaters require no extra supports.
Installation:
Allow for a proper sized opening on one side of the duct, as well as installation
clearances to avoid any obstructions around the duct. Rabie slip-in heater has a
standard 25mm flange on each side of the control box and can be attached directly to
the duct with sheet metal screws.

Flanged Type
Flanged heaters are designed so that the heater is
an integral part of the duct work. The heater frame
is attached to matching duct flanges. Standard
flange 25mm on the heater frame are used to
attach it to the duct. Flanged heater dimensions
match the dimensions of the duct.
Installation:
Rabie Flanged electric heater comes with 25mm
standard flanges installed around the frame and on
each side of the control box. It can be attached
directly onto the duct with sheet metal screws.

Design & Performance Data are subject to change without prior notice.

2
ELECTRIC AIR HEATER (REH)

(Continued from page 2)

Round Collar Type


Round collar electric heaters are available for
installation on round duct systems with a standard
diameter of 150mm to 600mm. They are provided with
one male and one female adapter for ease of
installation.
Installation:
Rabie round collar electric heater comes with a 25mm
extension on each side of the frame. The heater is attached directly onto the duct using
sheet metal screws.

Heating Elements:

Open Coil Elements (Standard)


We use resistance heating wire made of a ferritic
iron-chromium-aluminum alloy (FeCrAl alloy) for
use at temperatures up to 1400°C (2550°F). The
alloy is characterized by high resistivity and
very good oxidation resistance.

Standard Tubular Elements (Optional)

Tubular elements are made of Incoloy 800 (Nickel


alloy) tube with a diameter of 3/8" (9.5mm)
containing a heating coil in magnesium oxide
powder. Connections are made with two terminals.
The U or W shape of the tubular elements is
determined by the heater dimensions.

Finned Tubular Elements (Optional)


Finned tubular elements are made of Incoloy 800
(Nickel alloy) tube with a diameter of 3/8" (9.5mm)
containing a heating coil in magnesium oxide
powder. The tube is equipped with aluminum fins
to allow for more efficient heat dissipation.
Attachments are made with two terminals. The U
or W shape of the tubular elements is determined
by the heater dimensions.

Design & Performance Data are subject to change without prior notice.

3
ELECTRIC AIR HEATER (REH)

8.00

7.00

6.00
Air Velocity (m/s)

5.00

4.00 Finned Tubular


Standard Tubular
3.00
Open Coil
2.00

1.00

0.00
0 20 40 60 80

Pressure Drop (Pa)

1,400

1,200
Air Velocity (f/min)

1,000

800
Finned Tubular
600 Standard Tubular
Open Coil
400

200

0
0.00 0.05 0.10 0.15 0.20 0.25 0.30

Pressure Drop (in WC)

Design & Performance Data are subject to change without prior notice.

4
ELECTRIC AIR HEATER (REH)

Diagram 01:
Three phase supply
ON/OFF electric signal - 2
stages
(Optionally can be equipped
with disconnect switch, stage
fuses and pilot light options)

Diagram 02:
Three phase supply
Modulating (0-10VDC) electric signal - 3 stages
(Optionally can be equipped with disconnect switch, pilot light and stage fuses options).

Design & Performance Data are subject to change without prior notice.

5
ELECTRIC AIR HEATER (REH)

Calculations for Required Capacity:

SI-Units:

Where P in kW, Q in m³/s and T in °C

Imperial Units:

Q  (T2 − T1 )  1.08
P=
3413
Where P in kW, Q in CFM and T in °F

Design & Performance Data are subject to change without prior notice.

6
ELECTRIC AIR HEATER (REH)

10,000.00

1,000.00

100.00
Heating Capacity (kW)

10.00 5°C Temp. Rise


10°C Temp. Rise
20°C Temp. Rise
1.00

0.10

0.01
0.0 0.1 1.0 10.0 100.0

Air Flow (m³/s)

1,000.00

100.00
Heating Capacity (kW)

10.00 5°F Temp. Rise


10°F Temp. Rise
20°F Temp. Rise

1.00

0.10
100 1,000 10,000 100,000

Air Flow (cfm)

Design & Performance Data are subject to change without prior notice.

7
ELECTRIC AIR HEATER (REH)

8
PLENUM BOXES (PB)

Plenum box PBLS is designed to ensure equal distribution of air through the linear out-
lets. There is acoustic lining (Fixed with non-flammable adhesive and/or fasteners) in the
supply plenum box to reduce the noise which is generated inside the duct due to airflow
turbulence before reaching to the grill. The built in volume control damper can operate
from spigot connection or from face of the grill.

Casing Built of 24 gauge galvanized

Finish Mill galvanized.

Spigot Inlet with spigot or collar as per customer request.

Insulation 25mm thick and 24 or 48 kg/m³ density.

1
PLENUM BOXES (PB)

H
DAMPER BLADE

* Box width will be wider if ø > 2W +2’’. Consult factory

No. Of Slots (3/4”) 1 2 3 4 5 6 7 8


Width (inch) 1 13/16 3 1/4 4 3/4 6 1/4 7 11/16 9 1/8 10 9/16 12 1/16

2
PLENUM BOXES (PB)

PB Heel Spigot or Collar


At Heel (as shown)
or at Throat
End Cap

Neck

PBCS-H Curved Slot Plenum Box with Collar(s) or Spigot(s) at the Heel side
PBCS-T Curved Slot Plenum Box with Collar(s) or Spigot(s) at Throat side

3
PLENUM BOXES (PB)

Plenum box PBLB is designed to ensure equal distribution of air through the linear out-
lets. There is acoustic lining (Fixed with non-flammable adhesive and/or fasteners) in the
supply plenum box to reduce the noise which is generated inside the duct due to airflow
turbulence before reaching to the grill. The built in volume control damper can operate
from spigot connection or from face of the grill.

Casing Built of 24 gauge galvanized

Finish Mill galvanized.

Spigot Inlet with spigot or collar as per customer request.

Insulation 25mm thick and 24 or 48 kg/m³ density.

4
PLENUM BOXES (PB)

* Up to spigot size 12”, otherwise consult factory.

5
PLENUM BOXES (PB)

End Cap
Spigot or Collar
At Throat (as
PB Heel shown) or at Heel

Neck at Heel
(as shown) or
at Throat

PBCB-H Curved Bar Plenum Box with Collar(s) or Spigot(s) at the Heel side
PBCB-T Curved Bar Plenum Box with Collar(s) or Spigot(s) at Throat side

6
PLENUM BOXES (PB)

Plenum box PBSD is designed to ensure equal distribution of air through the diffusers.
There is acoustic lining (Fixed with non-flammable adhesive and/or fasteners) in the sup-
ply plenum box to reduce the noise which is generated inside the duct due to airflow tur-
bulence before reaching to the grill. The built in volume control damper can operate from
spigot connection or from face of the grill.

Casing Built of 24 gauge galvanized

Finish Mill galvanized.

Spigot Inlet with spigot or collar as per customer request.

Insulation 25mm thick and 24 or 48 kg/m³ density.

7
PLENUM BOXES (PB)

PBSD-T

3”

10”

1-3/4”

W+ 1-1/2”

PBSD-S

8
PLENUM BOXES (PB)

Hepa Filter Units are developed for use in critical applications where a very high filtration effi-
ciency is required, such as operation rooms, isolation rooms, food processing, ...etc. Our tech-
nical team considers all design requirements and provide proposals for approval.
In typical design for operation room, unit is manufactured of galvanized, stainless steel-304 or
SST-316. filters are provided with quick-release fasteners to replace them easily. Perforated dif-
fuser ensures laminar flow downward with piston pattern to avoid drafting. For multi sections, an
evacuated center module can be provided to pass the lighting bar through.
HEPA Filters are manufactured to the most exacting standards for critical applications. Each fil-
ter is individually certified to achieve an efficiency of not less than 99.97% and up to 99.999%

9
PLENUM BOXES (PB)

The model SRA (square to round) and SSA (square to square) neck adaptors are for
grills, registers and diffusers to provide an economical transition from square neck to
round neck in projects where flexible or round duct connections apply, or to a smaller
square neck.
SRA and SSA Adaptors are constructed of black coated steel Ga24.
SRA and SSA Adaptors are available in full range of size.

Ø = Nominal duct connection diameter

NOTE : - Nominal neck diameter should be smaller than A and B dimensions

10
PLENUM BOXES (PB)

H
W
ø

H
H

11
PLENUM BOXES (PB)

Fastener

Threaded rod

Stainless Steel Band & clamp


Flexible Duct

Nut & Bolt


With (Washer)

Plenum Box

Main Duct
Fixing Bracket

Spigot Damper Ceiling


LSD

Fastener
Nut & Bolt
WALL OR Threaded rod
PARTITION
Stainless Steel Band & clamp
Plenum Box
Flexible Duct

LBG

Main Duct

Spigot Damper
Fixing Bracket
OBD

Fastener

Threaded rod

Stainless Steel Band & clamp


Flexible Duct

Nut & Bolt


With (Washer)

Plenum Box
Main Duct
OBD
SCD
Spigot Damper Ceiling

12
DUCT ACCESS DOOR (DAD)

DAD-CH DAD-CC

The insulated access doors are made from galvanized steel sheet and is packed with
24 Kg/m3 fiberglass. It is designed to prove convenient and economical access to duct
components, neoprene gasket between the door and frame to assure a tight seal with-
out obstruction in the air stream. Available in different models, can also be modified
on a customer basis.

Casing Built of 24 gauge galvanized.

Door frame 24 gauge galvanized.

Finish Mill galvanized.

Insulation 25mm thick fiberglass (standard), or 50mm

(Not effected by moisture, oil and grease)

1
DUCT ACCESS DOOR (DAD)

1. Cam lock to duct (Optionally Notched) 6. Seal Gasket


2. Fiberglass Insulation 4. Access Door
3. Knock over extension for fixing 5. Frame

5
5

1
4

H
4
H

2 3

4
H

4 2 1

DUCT 6 3

2
DUCT ACCESS DOOR (DAD)

3
DUCT ACCESS DOOR (DAD)