Features
sensor
(B)
● Upgraded features Fiber
optic
- Anti-saturation setting function prevents malfunction by saturated light sensor
Specifications (J)
Counter
Display type Dual Display type Single Display type
NPN open collector output BF5R-D1-N BF5G-D1-N BF5B-D1-N BF5R-S1-N
Model
B-9
BF5 Series
Over
Main circuit
(Black)output Max.100mA
current
+ 12-24VDC protection + 12-24VDC
Over ±10% (Black)output
current Max.100mA - - ±10%
protection Load Load
(Blue)0V (Blue)0V
Dimensions
(unit: mm)
● BF5 -D1- ● Accessories
● Connector type wire(length: 2m)
● BF5R-S1-
10
● Side connector
48.4
2-Ø2.4
30
6
9.9
9.5
7.2
2 70
72 6.7
78.7
Installations
[Installation] [Removal]
Amplifier unit mounting ①
● Installation: Hang up the backside holder on the DIN
②
rail and press the unit toward the DIN rail.
● Removal: Slide the back part of the unit as the ①
figure and lift up the unit as the ② figure.
Amplifier unit connection
● Remove the side cover at the connecting side as the
figure ① and connect the side connector as the figure
②. ①
● After mounting the unit on the DIN rail, push gently ① ②
both units to fasten each other.
※Make sure that connections between the unit case
and connectors correctly. Improper connection may
cause malfunction of channel setting and mutual
interference prevention functions.
※Do not supply the power while connecting /
disconnecting amplifier units.
③
※35mm DIN rail
B-10
Fiber Optic Amplifier
①⑤
Fiber cable connection (A)
Photo
● Lift up the protective cover ① and push down the lock electric
sensor
lever to the direction of ② to release the lock setting. ②④
●Insert the cable to the direction of ③ with slightly (B)
Fiber
moving up and down 15˚, and gently press into the ③ optic
sensor
unit until the cable is completely inserted (inserted
length: around 13mm). (C)
Door/Area
●Lift up the lock lever to lock the lock setting ④ and sensor
(I)
SSR/
Power
12 1 2 3 4 6 12 1 2 7 8 9 10 controller
B-11
BF5 Series
● BF5R-S1-
RUN mode
Response time Anti-saturation Manual sensitivity Teaching Group teaching Display function Monitoring mode
sensitivity
Timer (Refer to B-22 page) (Refer to B-23 page) Standard display High Peak
(Refer to B-21 to 22 page)
Set
3020
value
2700
Min. 2500
Time
Teaching section: 2 sec.
Flashes twice (0.5 sec.)
※Press the SET key once and teaching starts. and returned to RUN mode
B-12
Fiber Optic Amplifier
2) One-point teach mode (A)
Photo
※One of teaching modes that sets the maximum sensitivity by teaching one sensitivity setting point when setting the SV electric
sensor
with no sensing object (Reflective) or when setting the SV with incident light level 0(Through-beam) / Suitable for the
applications required little effect of dust or background. (B)
Fiber
● Set Teaching mode parameter [ SENS ] to IPNT. Press key optic
sensor
Incident light level
3400
Max. (C)
2760 Door/Area
sensor
2757
2760
(D)
Proximity
sensor
2750
(E)
2500 Pressure
sensor
Time (F)
Rotary
Teaching section: 2 sec. encoder
Flashes twice (0.5 sec.)
※Press the SET key once and teaching starts. and returned to RUN mode
※SV range for sensing distance. (G)
Connector/
Socket
Response Time Teaching when incident light level is 0 Teaching when incident light level is saturated
UFST (H)
FST In case incident light level is 0, set to 10 digit. In case incident light level is saturated, set to 3980 digit. Temp.
controller
STD
(I)
LOG SSR/
In case incident light level is 0, set to 5 digit. In case incident light level is saturated,set to 9980 digit. Power
ULOG controller
※One of teaching modes that sets the sensitivity using average value of two incident light levels obtained from two point
teaching - one point with a sensing object and the other point without a sensing object. (K)
● Set Teaching mode parameter [ SENS ] to 2PNT. Press key Timer
Incident (L)
light level Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
280
(N)
Min. 250 Display
Time unit
※Press the SET key once and teaching starts..
Flashes twice
(0.5 sec.) (O)
Incident Teaching section: 2 sec. Sensor
controller
light level
Max. 3400 (P)
Switching
Press key mode power
3200 supply
Min. value
teaching (Q)
Stepper
motor&
Driver&Controller
Min. value
teaching (R)
Graphic/
Logic
panel
250
Min. Time (S)
※Press the SET key once and teaching starts. Field
network
device
Incident
light level Teaching section: 2 sec.
Max. 3400 (T)
Software
Flashes twice
PMax+PMin (0.5 sec.)
Set_value = (U)
Set 2 Other
Value 1825
250
Min.
Time Flashes twice (0.5 sec.)
※Make sure that two point teaching must be done within 60 sec after one point teaching. and returned to RUN mode
If not, teaching mode is cancelled and it returns to RUN mode.
B-13
BF5 Series
4) Positioning teach mode
※One of teaching modes that sets the sensitivity to 90% of max. incident light level when sensing an object with a hole on
the surface (Through-beam) or sensing a moving object having curve (Reflective).
● Set Teaching mode parameter [ SENS ] to PSTN.
Incident
light level
Max. 3000 Press key
Set 2700
Value
Min. 100
Time
Teaching section: 2 sec.
Group Teaching
RUN mode
TCHI ALL
At Group Teaching mode of
Master unit, select YES and
Slave units automatically
key
TCHI NO TCHI YES operates.
※1
CH8 OK
TCHI ---- TCHI END Channel 8 ※In case of 8-channel
The Master unit starts teaching after ※1 (Up to 32 channels
teaching command transmission to TCHI ---- Teaching for each Slave unit is Automatically available)
Slave unit is completed. executed in sequence. returned to RUN
mode after flashing
Automatically returned to RUN mode TCHI END twice.
after flashing twice.
RUN mode
※1: Display part status while teaching is in the process
B-14
Fiber Optic Amplifier
● Master / Slave unit display during group teach mode (A)
Photo
Master Master Master electric
sensor
unit Slave unit (RUN mode) unit Slave unit unit Slave unit
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
Press SET key
Master
① The Master unit displays channel number on the PV display part and unit Slave unit (F)
Rotary
OK on the SV while group teaching executes. encoder
② Slave units display TCHI on the PV display parts and ---- flashes
(G)
every 0.5 sec on the each SV display parts while group teaching Connector/
executes. When teaching is completed, Slave units flash SV twice Socket
and display TCHI on the each PV display part and END on the SV
(H)
display parts. Then, they automatically return to RUN mode. Temp.
controller
③ The Master unit starts teaching after transmitting teaching command
to Slave units. When teaching is completed, the Master unit flashes (I)
SSR/
SV twice and displays TCHI on the PV display part and END on the Power
controller
SV display part. Then, they automatically return to RUN mode.
(J)
Counter
Automatically moved
(O)
Response Standard Ultra Sensor
Long-distance Ultra fast Fast
time long-distance controller
, key , key , key , key
RSPD STD RSPD LONG RSPD ULOG RSPD UFST RSPD FST (P)
Switching
mode power
supply
(Q)
Display Normal Percentage Stepper
function display key display motor&
Driver&Controller
DSPF 4000 DSFP 999P
(R)
key Graphic/
Logic
panel
(T)
Software
Timer ON OFF
operation
mode Delay Delay One-shot
key key key (U)
TMOD OFF TMOD OND TMOD OFD TMOD SHOT Other
key
Time setting
※Set the , keys to set 1 to 5000 ms.
TIME 2000 ※In case timer operation mode parameter [ TMOD] is set to OFF,
time setting parameter [ TIME] is not be displayed.
B-15
BF5 Series
Sensitive
setting Auto 1 point 2 point Position
mode
key key key
SENS AUTO SENS 1PNT SENS 2PNT SENS PSTN
key
Light ON/
Dark ON Light ON Dark ON
key
LDON L-ON LDON D-ON
Channel
CH 1 ※Connected unit is automatically set channel (1 to 32).
You can only check channel numbers.
ON Delay L/O T T
ON Delay D/O T T
One-shot L/O T T T T T
One-shot D/O T T T T T
※Setting time: T>Ta , T>Tb , T>Tc>Tb
B-16
Fiber Optic Amplifier
Energy saving function [ESAV] (A)
Photo
A function to save unit's power consumption by reducing power supply to display parts in case of no setting input within 60 electric
sensor
sec.
● Selectable from 2 power saving modes (B)
Fiber
- Normal mode [NOR]: Main output indicator(OUT), PV/SV display part ON optic
sensor
- Energy saving mode 1 [1SAV]: Main output indicator(OUT) and PV display part ON
- Energy saving mode 2 [2SAV]: Main output indicator(OUT) ON (C)
Door/Area
Light ON / Dark ON switching function [LDON] sensor
A function to set Light ON - control output is ON when incident light level is higher than setting value Dark ON - control (D)
output is ON when incident light level is lower than setting value. Proximity
sensor
Communication enable / disable setting function [COMM]
A function to set communication write [enable( ENA) / disable(DISA)] for Slave amplifier units while certain instructions (E)
Pressure
(Load/Save/Copy) or Group teaching is in progress by the Master amplifier unit. sensor
: Check available
Parameter initialization : Check / Setting both unavailable
(I)
SSR/
Power
● In case of [LOC2]mode, it is required to disable the lock function first to enter into parameter mode. controller
(J)
Data Bank setting Counter
A function to save settings for group amplifier units in each data Bank by using Master unit's command or by adjusting one
amplifier unit's setting and to load required data Bank when it is necessary without resetting for each unit's parameters and (K)
Timer
setting values.
● LOAD [LOAD]: Loads preset dataBank(BAK0, 1, 2) and applies it to the amplifier unit.
(L)
Detailed Bank parameters can be read and changed. Panel
meter
● SAVE [SAVE]: Saves one amplifier unit settings in one of dataBank(BAK0, 1, 2).
● COPY [COPY]: Copies the currently loaded Bank by Master’s instructions to the other amplifier unit (1:1) or the whole (M)
Tacho/
amplifier units (1: M). Speed/ Pulse
meter
● LOAD ALL [LDAL]: Selects one dataBank by Master’s instructions loads it to entire group units.
● SAVE ALL [SVAL]: Selects one dataBank by Master's instructions and saves it in entire group units. (N)
Display
※For BF5 -D1- , three dataBanks are available ([BAK0], [BAK1] and [BAK2]) so that three different sensing object unit
information can be saved. Each Bank can be read and changed. It allows users to detect three different sensing
objects with one amplifier unit without resetting each parameter. (O)
Sensor
controller
※DataBank function can be executed only if all amplifier units are in RUN mode.
※Copy/Load All/Save All functions are applicable only if multiple amplifier units are connected. (P)
Switching
※If lock function is set( LOC1/ LOC2) on amplifier units or if the Slave unit is set to communication disable[DISA], mode power
supply
Load and Save command for the unit does not execute.
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
B-17
BF5 Series
Data Bank mode flow
RUN mode
Press for 5 sec. ※Press key for 3 sec. to return to
Data Bank setting mode display RUN mode in data Bank mode.
DATA BANK
Automatically moved after flashing twice (0.5 sec.).
Bank
Data
load Bank0 Bank1 Bank2
key key RSPD STD
LOAD BAK0 LOAD BAK1 LOAD BAK2 DSPF 4000
key DIR 1234
TMOD OFF
Press key to stop reading and TIME 2000 ※In case timer operation
changing each bank data. SENS AUTO mode parameter [TMOD]
is set to OFF, time setting
Press key to load certain bank and ESAV NOR
parameter [TIME] is not
to read / change bank data. LDON L-ON displayed.
CH 1
Data COMM ENA
save Bank 0 Bank1 Bank2 LOCK OFF
key key
SAVE BAK0 SAVE BAK1 SAVE BAK2 SET※1 2000 ※1: [SET] parameter is not
kisplayed in program
key
mode.
key
SAVE NO SAVE YES SAVE END
Data
copy 1:1 copy 1:M copy
key
COPY S--S COPY S--M
key
COPY CH02 COPY CH32 COPY ALL
※2
COPY END
※2: Refer to Master / Slave unit display
during data Bank setting (Page B-19).
Load all Bank 0 Bank 1 Bank 2
key key
LDAL BAK0 LDAL BAK1 LDAL BAK2
key
key
LDAL NO LDAL YES LDAL END
※2
key
SVAL NO SVAL YES SVAL END
※2
B-18
Fiber Optic Amplifier
Master / Slave unit display during data Bank setting (A)
Photo
● Copy All Master Slave units Master Master Slave units
electric
sensor
unit (RUN mode) unit Slave units unit (RUN mode)
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
Press key
(F)
① While Copy All is executed, the Master unit displays the channel number on the PV display part and OK on the SV Rotary
encoder
display part.
② While Copy All is executed, the Slave units display RX on the PV display part and OK on the SV display part and they (G)
return to RUN mode. Connector/
Socket
③ When Copy All is completed, the Master unit displays COPY on the PV display part and END on the SV display part.
Press the key to return to Data Copy mode.※In case of 1:1 Copy, it progresses as same. (H)
Temp.
controller
● Load All Master Slave units Master Master Slave units
unit (RUN mode) unit Slave units unit (RUN mode) (I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
③ When Load All is completed, the Master unit displays LDAL on the PV display part and END on the SV display part.
(O)
Press the key to return to Load All mode. Sensor
controller
● Save All Master Slave units Master Master Slave units (P)
unit (RUN mode) unit Slave units unit (RUN mode) Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
B-19
BF5 Series
Max. Min.
incident incident
High peak light level Low peak light level
HPEK 4000 HPEK 3000 LPEK 1000 LPEK 950
Initialize to current Initialize to current
incident light level incident light level
RUN mode
① Press the key for a sec to monitor max/min incident light level.
② Press the key to initialize max/min value to current incident light level during monitoring.
③ Press the key to return to RUN mode.
Initializing function
A function to initialize all parameters in memory to default value in case the possibility of mis-setting or mis-operation.
※Set lock function [LOCK] to OFF to execute Initializing Function.
※High peak value[HPEK] and low peak value[LPEK] shall not be initialized.
Parameter initialize flow
RUN mode ① P ress the key for 7 sec. in RUN mode.
INIT parameter turns ON on PV display part and
Press key for 7 sec.
NO flashes every 0.5sec. on SV display part.
key
INIT NO INIT YES INIT INIT ② Press the key once again to return to RUN
mode without executing initializing Function.
③ Select YES using the , keys and press the
Automatically moving key. INIT flashes twice on both PV and SV
※Automatically returned to RUN
mode after flashing twice display parts.
RUN mode
④ When parameter initialization is completed, it is
automatically returned to RUN mode.
Parameter value for initialization (factory default)
Parameter Factory default Parameter Factory default Parameter Factory default
RSPD STD TMOD OFF LDON L-ON
DSPF 4000 SENS AUTO COMM ENA
DIR 1234 ESAV NOR LOCK OFF
SV: 2000, Bank 0 to 2: Initialized
B-20
Fiber Optic Amplifier
※There are two methods available for sensitivity setting - manual or teach mode. optic
sensor
Previous SV SV
key key (E)
Pressure
sensor
(F)
Rotary
encoder
① Press the or key once in RUN mode, then previous SV flashes twice(every 0.5 sec.).
② Press the and keys to set the value. (G)
③ There is no additional key for completing the setting. If there is no key input for 3 sec after completing setting, newly set Connector/
Socket
value flashes twice (every 0.5 sec) and automatically save it and returned to RUN mode.
(H)
Teaching sensitivity setting(Auto tuning) Temp.
controller
● For BF5R-S1- model, teaching sensitivity setting mode is fixed to auto-tuning. (I)
※This mode is easy the sensitivity when incident light level of sensing object is not stable or moved fast. SSR/
Power
※One of teaching modes that sets the sensitivity using average value of the maximum and minimum incident light level controller
Incident
light level
(K)
Max. 3400
3300
P1+P2+ ··· +Pn-1+Pn Timer
Set_value =
3200 n
(L)
Set Panel
3020 meter
Value
(M)
Tacho/
2700 Speed/ Pulse
meter
Min.
2500
(N)
Display
unit
Time
Teaching section: 2 sec.
(O)
Sensor
※Press the SET key once and teaching starts. controller
(R)
1800 Graphic/
Logic
panel
① In RUN mode, press the key once with the desired sensing target.
(S)
② When pressing the key once, and teaching starts and progresses automatically for 2 sec. Field
network
③ After completing teaching, OK is flashes twice for 0.5 sec. and it returns to RUN mode. device
(T)
Software
(U)
Other
B-21
BF5 Series
Function
Response time setting
Use front slide switch to set response time.
● Fast(FAST) mode: 150㎲
● Standard(STD) mode: 500㎲
● Long distance(LONG) mode: 4ms
<When changing to standard display mode> <When changing to percentage display mode>
Press (D) key Automatically Press (D) key Automatically
for 3 sec returns for 3 sec returns
RUN mode 999P RUN mode RUN mode 4000 RUN mode
Timer function
※For the BF5R-S1- model(single display type), only OFF Delay mode is available. Select the setting time
(OFF/10ms/40ms) using the front slide switch.
● Time chart [ T = 10ms or 40ms]
Sensing condition Ta Ta Ta Ta
4000 2100
Press + key Press + key
B-22
Fiber Optic Amplifier
CH8 OK (K)
Timer
Automatically Teaching※1
executed processed
(L)
Panel
The Master unit starts teaching after Teaching※1 Teaching for each Slave unit is meter
teaching command transmission to processed executed in sequence.
Slave unit is completed. (M)
Automatically Tacho/
executed Automatically Speed/ Pulse
meter
executed
END
(N)
Automatically Display
executed Flashes twice unit
END (every 0.5 sec.)
2000 (O)
Automatically Automatically Sensor
controller
executed executed
(P)
Teaching SV flashes
Flashes twice
TCHI END 2000 twice(every 0.5 sec.)
Switching
mode power
(every 0.5 sec.) supply
(Q)
Automatically returned to RUN mode Automatically returned to Stepper
motor&
when group teaching is completed. RUN mode . Driver&Controller
(R)
Graphic/
Logic
RUN mode panel
(S)
Field
※1: Display part status while teaching is in the process network
device
(T)
Software
0 sec. 0.5 sec. 1 sec. 1.5 sec.
B-23
BF5 Series
RUN mode
Error code
Error code Cause Troubleshooting
In case incident light level is below the min. range when
ERRL Increase the incident light level above min. range.
teaching.
ERR In case overcurrent inflow occurs into output circuit. Remove overcurrent due to overload.
B-24