1 2 3 4 5

10'-11" 4'-9" 2'-721" 4'-9"

1'-3"

C1 2' C2
A
F2 2' F2
WELL
7'-7"

2'-9"
B
C2
F1 6'-6"
6'-9"
8'-9"
3"
C
C1 F1 C3
C1 F2
9'-121"
[2.78]

16'-3"

4'
C1 3' 3"
D
C3
3'
C1
F2
5'-11" F3

E
4'-8" 4'

421" C3 421" C1
F 4'
C1 F2 F4 F4
18'-3"

23'

7 7

NOTE:
1. Design :G+ 1 - S.B.C for soil shall not be less than 30T/sq.m
2. # - Indicates dia of high strength deformed bars of
grade Fe:500 conforming to is:1786 - 1985.
3. Use concrete mix - M35 grade and cement - 53 grade
N
4. Curing period for all structural concrete is 28 days.
5. Clear cover to main reinforcement shall be as follows and

8
concrete cover blocks (or) pvc cover blocks are to be used
A) For footings - 75 mm (3") B) For columns - 40 mm (1.5")
6. General lap length to column reinforcement-
50 times the bar diameter
8. Provide a lap length of 60 d for beams and slab
reinfoecements where d is diameter of main bars
W E
7. Reinforcement in the slabs shall be cranked at 0.21l 9. ±0.0 LVL taken as ground floor F.F.L
from support and extra rods shall be for 0.31 length
unless specified otherwise where l is clear span