c Clamp Open Guard®

Operation & for Standard Masts 2 Locate the white plastic cover
Display

Adjustment (Non-Freelift)
on the main lift pressure switch.
Remove the screw on the cover
and pry off the cover. The
hexscrew allows adjustment in
step 3.
Operation 3 Raise the mast carriage. Main lift
• When the green light is on, the clamp will open and close normally. When the • Turn the hexscrew in the Pressure
amber light is on, the clamp will not open. switch CCW until the amber Switch
light goes on, then turn back
• During fast lowering of the attachment, the lights may flicker between amber CW to just when the green
and green, this is normal. light goes on and then an
additional 1/4 turn.
NOTE: The system does not work like a drop stop valve that prevents load
drop or jump when the clamp is opened. The green light does not indicate • If one of the lights stays on all
that the load has been lowered to its optimal position. the time and does not switch
to the other light, troubleshoot
the wiring connections.

This product is no longer


in production under its
current configuration and
is subject to a product
improvement field campaign. AC0490.ill

Adjustment Main lift


The following adjustments must be done with the attachment that will be used Pressure
Switch
with this specific lift truck.

LI EE
1

FR
FT
Test the installation before putting the truck in service. Initially when the
truck key is ON, one of the lights on the display should be on. Check the
wiring if the display is not lit.

AC0816.ill
(Continued)

cascade
corporation
For Technical Support . . .
Call: 1-800-227-2233
OR
Write: Cascade Corporation, P.O. Box 20187, Portland, OR 97294 Cascade Corporation 2012 5-2012 Part No. 6029037-R1