Ring Main Units

ARMU Series
ARMU 12 | ARMU 24 | ARMU 36
Ring Main Units
ARMU Series

ARMU series Ring Main Units are switching and


control cubicles; manufactured up to 36 kV, 630 A,
20 kA for single busbar distribution. The main tank
is “sealed for life” thus guaranteeing protection
against SF6 gas leakage for more than 30 years
and reduces maintenance.

There are Extensible and Compact options which


consist of the combination of following types.

• Compact 2L + 1T • Extensible L
• Compact 2L + 2T • Extensible T
• Compact 3L • Extensible I
• Compact 3L + 1T • Extensible 2L + 1T
• Compact 4L
• Compact 4L + 1T Standards
• IEC 62271-1 • IEC 62271-103
L unit is equipped with a 3-positions load break
• IEC 62271-100 • IEC 62271-105
switch. It is mainly used for incoming and outgoing
• IEC 62271-102 • IEC 62271-200
feeders in ring networks.
I unit is equipped with a 3-positions load break Color
switch and circuit breaker. It is mainly used at
• RAL 9003 for front cover
incoming, outgoing in ring networks.
• RAL 7015 for side cover
T unit is used when an outgoing transformer
with fuse protection is required. The transformer Application Areas
unit can be equipped with IMS opening coil.
• Renewable Power
For earthing the fuses, the integrated earthing
• Power Distribution
disconnector used on the upstream side, while an
• Transformer Substation
additional earthing disconnector is needed on the
• Buildings and Industry
downstream side of the fuses.
• Transportation and Infrastructure

Single Line Diagram of Typical Units


Advantages
T Unit
L Unit I Unit
Incoming/Outgoing
Switchgear with LBS
Transformer
Switchgear with
LBS & Fuse
Incoming/Outgoing
Switchgear with CB • Full insulation with lifetime sealing
• Factory routine tests on 100% of the units
• Easy front access to install and test
• Medium-voltage cables and fuses
• Compact size and lightweight
• Indicators for voltage presence
• 5 years warranty option

Safety
Service Conditions • Internal arc classification IAC AFL
Application Area Indoor • Classified LSC-2A, PM
Altitude 1000 m
• Safe mechanical and electrical interlock
Ambient Temperature Min. -5°C
Max. 40°C
• Continuity of earthing system
Average period of 24h 35°C • 2 mm sheet steel construction
Humidity Max. (period of 24h) 95% • All live parts are housed in a hermetically
Max. (period of one month) 90% sealed gas tank
Ambient Pollution Light • Prevent unsafe operation
Technical Specifications

Line Load Break Switch


Rated voltage (rms) kV 12/24 36
Withstand rated voltage earthing phase kV 125 170
Withstand rated voltage disconnecting distance phase kV 145 195
Rated short duration power frequency withstand voltage (1 min.) kV 50 70
Rated short duration power frequency withstand voltage (1 min. disconnector distance) kV 60 80
Rated frequency Hz 50/60 50/60
Rated current A 630 630
Short time withstand current kA 20 20
Rated short time withstand (peak) current kA 52 52
Short circuit current withstand time s 1 1
Protection class IP30 IP30
Active load breaking current A 630 630
Open loop breaking current A 630 630
Mechanical operation class M1 M1
Electrical operation class E3 E3
Short-circuit breaking capacity (making) kA 52 52
Internal arc protection (AFLR) current kA 20 20
Internal arc fault duration s 1 1

Line Earthing Switch


Rated short time withstand current kA 20 20
Rated short time withstand (peak) current kA 52 52
Short circuit time s 1 1
Short-circuit breaking capacity (making) kA 52 52
Mechanical operation class M0 M0
Electrical operation class E2 E2

Transformer Protection Earthing Switch


Short circuit current withstand time s 1 1
Current peak value of short duration kA 2.6 2.6
Short time circuit time s 1 1
Short-time closure capacity (making) kA 2.6 2.6
Mechanical operation endurance class M0 M0
Electrical operation endurance class E2 E2

Voltage (kV) Type Wıdth (mm) Depth (mm) Heigth (mm) Weight (kg)
L 381 180
T 521 236
12 - 24 2L+T 1271 762.5 513
3L 1130 460
4L 1406 610
L 381 1408 190
T 601 266
2L+T 1351 540
36 862.5
2L+2T 1948 780
3L+T 1726 481
4L+T 2100 720
Doc. Nr: ARMU-20230504/En Owing to periodical improvements of our products the supplied products may differ in some details from the data stated in the prospectus material. Published
by Aktif Data subject to alteration without notice. Design & Creation: Aktif / Photos: Aktif - Stock.xchng & Shutterstock, Published Date: 14.03.2023

Headquarters Germany Office HV Factory LV Factory


Bayraktar Bul. Şehit Sok. No: 5 Bahnhofstrasse 82-86 Akşemsettin Mah. Çatalca Sk. No: 113 06930 Kargalı Hanbaba Organize Sanayi, 2. Sk.,
34775 Ümraniye, İstanbul, TR 35390 Giessen, Germany Sincan, Ankara, TR No: 5, Hendek, Sakarya, TR
Phone : +90 (216) 314 93 20 Phone : +49 176 60940534 Phone : +90 (312) 269 46 02 Phone : +90 (264) 276 64 50
Fax : +90 (216) 314 93 60 www.aktif.net Fax : +90 (312) 269 45 01 Fax : +90 (264) 276 64 52
www.aktif.net - info@aktif.net info.de@aktif.net www.aktif.net - info@aktif.net www.aktif.net - info@aktif.net

You might also like