Calibration For Temperature Sensor

1. Filling the vessel and BWMS basic information


NO. Content Picture

1 Ship Name:Gener8 Atlas

2 IMO Number: 9322281

Calibration Location:
3
Houston,USA(reference)
Serial NO of Calibration
4
Instrument: JC 00073

5 Calibration Location: Houston,USA(reference)

6 Meter Type: TEMPERATURE


SENSOR
7
Serial No: B17101C1
8 Calibration Date: 2019/10/18(年/月/日)

2. Calibration
2.1 Calibration materials and tools
NO. Name Quantity Picture

1 Beaker 3~4pcs
2 EC300A 1 pcs

Temperature
3 1 pcs
sensor A

Temperature
4 1pcs
Sensor B

2.2 Calibration Procedure


NO Procedure Picture

Shut down the


BWMS ( Control
1
Unit Power off)

Prepare a clean
beaker and place the
water sample. Wash
2 the beaker once
before use to ensure
the accuracy of the
data

Connect the
EC300A, press the
green switch key--
turn on; Press the
Mode key to switch
to the measuring
3 interface. The first
row shows the
salinity value (PPT)
and the second row
shows the
temperature value
(c) . Keep the
electrodes clean.
Put the electrode
probe into the water
to be tested. The
probe should not
enter the water
beyond the black
part.

After 2 minutes,
read the temperature
on the display.

5 Prepare two different temperature water in advance, per beaker 500 ml


a. 1# : water from the fridge, suggest temperature
5℃~15℃(41℉~59℉)
b. 2# : normal temperature water, advised
temperature30℃~40℃(86℉~104℉)

c. Prepare two 500ml beaker for 1# and 2# water sample


Remove the
temperature sensor
from the EUT.
There are two kinds
of temperature
6
sensor A,B. Do the
following operation
for A type
(attention: don’t
remove the cover)

c
d

Start the
BWMS ( Control
Unit Power
on ) , then check
the present
7
temperature on the
PIPE display, and
record it on the
Annex sheet A--Test
Value.

Put the temperature


sensor B
electrode into the
8 sample water and
don’t rotate the
top part of
connecting cable

Directly check the


temperature on the
PIPE display, and
9
record it on the
Annex sheet A--Test
Value.
Put the 1# water
into beaker. Then
put the Temperature
sensor of EUT into
the beaker at the
same time with the
portable sensor.
Power on the
portable sensor and
10
press the Mode,
then read the
temperature and
record it on the
Annex Sheet A --
Reference Value.

Repeat the step 7, 8 to test the 2# sample water and record it


11
Repeat the step 6,7 to test the 2# sample water and record it.
Annex A--Object
Object
Ship Name: JAG AJAY IMO Number: 9723849

Calibration
JEBEL ALI, UAE
Location:

TEMPERATURE
Meter Type: Serial No: B15120A106_TS
SENSOR

Serial NO of
Calibration Date: 27/06/2020 Calibration JC02090
Instrument

1# data records
Meter
Condition Reference Result
online

Reference Test
Time
NO. Medium Value Value
Minute
℃ ℃

1 2 Water 40.3 40.7 -0.4 PASS

2 4 Water 40.6 40.9 -0.3 PASS

3 6 Water 40.8 41.0 -0.2 PASS

2# data records
Meter
Condition Reference Result
online
Reference Test
Time
NO. Medium Value Value
Minute
℃ ℃

1 2 Water 40.15 40.8 -0.65 PASS


PASS
2 4 Water 40.35 40.9 -0.55
PASS
3 6 Water 40.65 41.0 -0.35

Certified by: Roy Johnson


Date: 27-06-2020
ATTENTION:
Crew could simply adjust the result, if not right please retest and
record.:
Simple Calculation Formula:
Differentials =Reference-online=±X,
x<0.7 =====PASS
If test 3 times, none of the results pass, please contact the maker and send it back for
rectification.

Certified by ________
Date______________