-Confidential Level Info-

[Description]
It is found that repeating "charge after a short period of use" may result in shorter time to use the
battery pack.
The software to improve this issue (V1.10) is released. Update the applicable batteries following the
attached Update Manual.

<Note>
When fully charge the battery from the state where it is fully discharged (voltage is 11V or less), this
symptom will not occur, but updating is recommended.

[Compatible Combinations for Installation]

TO
V1.00 V1.10
From
V1.00 OK
V1.10 OK

[Applicable serial number]


BP-GL95B (SY):1000001 - 1002040
BP-GL95B (CN):5000001 - 5000390

[Preparation]
Prepare the JIG kit and required software files for firmware update.
For details, refer to the firmware update procedure for BP-GL95B.
(BP-GL95B_UpdateManual_E.pdf)

<Software File and Update Manual >


File name:BP-GL95B_V1.10.zip
* Obtain it from TiSS site.

This zip file includes:


(1) EV2400_Support_Components_20110524.exe (Driver software for EV2400)
(2) FirmWear_BP-GL95B_0110_updater_English.exe (Firmware updater for BP-GL95B)
(3) BP-GL95B_UpdateManual_J.pdf (Firmware update procedure (Japanese version))
(4) BP-GL95B_UpdateManual_E.pdf (Firmware update procedure (English version))
[Installation Procedure]
Refer to the firmware update procedure for BP-GL95B(BP-GL95B_UpdateManual_E.pdf).

[Confirmation / Adjustment]
Refer to the firmware update procedure for BP-GL95B(BP-GL95B_UpdateManual_E.pdf).

[Cause / Background / Supplement]

Cause is a software issue of the battery pack.


When charging from a state where it is not fully discharged, a small difference will occur in the
actual charged capacity, and the capacity after fully charged will decrease. The difference per charge
cycle is not big, but if repeat such a charge cycle, this difference will gradually accumulate.
When charging from the state where it is fully discharged (voltage is 11V or less), this difference will
not occur.
In addition, the accumulated difference is reset once and the capacity return to the normal state once.
However, if repeat the same charging cycle again afterwards, the difference will start to accumulate
again, so it is necessary to update to the countermeasure software as a permanent countermeasure.

<NOTE>
For security reasons, it is strictly prohibited to lend or provide jig kits and required software files for
F/W updates to anyone other than Sony and ASC/ASD.

[Software History]

V1.00 Initial version of the production unit Not disclosed


V1.10 Software Release [V1.00 => V1.10] 2021/09/23