Models 71 and 72 502.969.

8000 Leverless Limit Switches

Round Switches
Models 71 and 72

GO Switch Models 71 and 72 have the smallest 1.00" (25mm)


A.F. ON HEX
diameters of any round leverless limit switch, and are 3/8"-24 UNF-2A
3/8"-24 UNF-2A
THREADS X 1.50"(38mm) LONG
used extensively in factory automation applications. THREADS X 1.50"
(38mm) LONG

Features: 1.15”
SPDT 4A contacts (29mm)

Intrinsically Safe
1.55" .625"
-400 to 2210F operating temperature .625" (39mm) (16mm)
(16mm)
Options: 3.38"
Suitable for Zone 0, 1, or 2 explosion proof 1.55" 1.25” 1/2"-14 NPT
CONDUIT OUTLET
(86mm)
(39mm) (32mm)
-400 to 4000F high temperature
Quick disconnect connector 3.93"
(100mm)
English or Metric threads

Model 71 Model 72

Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options

Repeatability: .002" (.05 mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT SAA Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires,
2 303 stainless steel
sawtooth surface configuration rated at 221OF (105OC) 600V UL / CSA listed
(rated 2,000 PSI) 2 High temperature to 400OF (204OC)
Response Time: 8 milliseconds Sensing Range: Approx. .040" (1 mm) 2 Side entry (Model 72) A2 36" (914 mm)
Form: SPDT, Form C end sensing (Approval must be 8)
with TeflonTM insulated leads
A3 72" (1829 mm)
Differential: Approx. .020" (.51 mm) 6 316 stainless steel (Wiring must be F)
(Wiring must be F) A4 144" (3658 mm)
Ratings: Resistive Sensing Range with Target Magnet: (rated 2,000 PSI)
3 UL listed explosion proof for Cl I, Div A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
Operating Temperature: -40O to 221OF up to .15” (4 mm)
AC DC
5 Bottom of enclosure 1 & 2; Grps A,B,C,D; Cl II, Div 1 & 2,
(-40O to 105OC). HiTemp option to 400OF Volts Amps Volts Amps
O
(204 C)
Grps E-G; Cl III (Model 71) (Lead seal Cable 18 Gauge (.250" dia.) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA listed
120 4 24 3 6 Standard sensing - approx. .040"
240 2 48 1.25
req'd within 18") B2 36" (914 mm)
(1 mm) end sensing
71 Model 71 480 * 125 0.5 4 CSA certified explosion proof B3 72" (1829 mm)
3
/8" (10 mm) dia. x 3 15/16" (100 mm) 250 0.5 for Cl I, Div 1; Grps A,B,C,D; Cl II, B4 144" (3658 mm)
long, with 3/8"-24 UNF x 11/2" Div 1; Grps E-G; Cl III (Model 71) (Lead B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
(38 mm) threads and 1/2" NPT seal req'd within 18")
conduit hub 1 Single Pole Double Throw Water Resistant 18 Gauge (.250" dia) PVC cable rated at 176OF (80OC) 300V with water-
6 CSA certified Cl I, Div 2; Grps
(Form C) resistant squeeze connector. (Model 72) UL/CSA listed
71M Model 71 A,B,C,D; Cl II, Div 2; Grps E-G; Cl III
C2 36" (914 mm)
M12 x 1 external metric thread (Model 71) (Wiring must be A, B, or F)
C3 72" (1829 mm)
(Lead seal req'd within 18")
C4 144" (3658 mm)
72 Model 72
3
/8" (10 mm) dia. x 3 3/8" (86 mm) 7 CSA certified General Purpose C_ _ _ Lengths greater than 144" (Specify length in feet (e.g. C150 = 150 ft. of cable))
long, with 3/8"-24 UNF x 11/2" 8 UL listed General Purpose
(38 mm) threads. No conduit hub Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case
A SAA: Ex s IIC T6 IP65; Cl I Zone 1 & ground) (Approval must be 7 or 8) Refer to pp. 93-104 for mating cable assemblies and
72M Model 72 2; EX S IIC T6 IP65; Cl I Zone 0; DIP Aura Light Adapters.
M12 x 1 external metric thread Cl II (Intrinsically safe with entity approved Mini-change® Micro-change®
Extended Sensing Range with barrier. Install per NEC Article 501.) (Wiring DCA ®
3 pin Mini-change type DBA 3 pin Micro-change® type
Need Accessories?
External Target Magnets must be A) (Model 71) DCD 4 pin Mini-change® type DBD 4 pin Micro-change® type
(See Accessories for External Target Magnets) See pp. 93-104 for: DCG 5 pin Mini-change® type DBG 5 pin Micro-change® type
B SAA: High Temp EX S IIC T6 IP65;
Form C - SPDT Range Extending Cl I Zone 1 & 2; EX S IIC T6 IP65;
Magnet Sensing Differential Target Magnets HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF (250oC))
Cl I Zone 0; DIP Cl II (Intrinsically safe
AMP3 .12" .07" Mounting Brackets with entity approved barrier. Install per NEC 600V UL / CSA listed (Approval must be 2, 3, 4, 6, 7, 8, or B)
AMS4 .15" .10" Connectors and more! F2 36" (914 mm)
Article 501.) (Wiring must be F) (Model 71)
AMS7 .13" .045" F3 72" (1829 mm)
Ordering Guide F4 144" (3658 mm)
Fill in the boxes to create your F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
‘ordering number.’
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options
- -
40 71 1 6 41
Models 73 and 74 502.969.8000 Leverless Limit Switches

Round Switches
Dimensions
Models 73 and 74

The GO Switch Model 73 is our most popular leverless


limit switch. Its solid stainless steel construction and 73-13523-A2 1.00" (25mm)
A.F. ON HEX
Class I Div 1, 3 ft. leads 5/8"-18 UNF-2A THREADS 5/8"-18 UNF-2A
global certifications make it the ideal choice for a THREADS .625"
73-13524-A2
variety of applications. Model 74 is the same, less the Class I Div 1, 3 ft. leads
(16mm)

conduit hub.
73-13526-A2 1.15"
Class I Div 2, 3 ft. leads (29mm)
Features: 73-13528-A2
SPDT 4A contacts General Purpose 3 ft. leads 1.88"
(48mm) 1.88"
Intrinsically Safe 73-13528-DCA 1/2"-14 NPT
(48mm)
CONDUIT OUTLET
-400 to 2210F operating temperature General Purpose, Mini Connector 2.50"
(64mm)
2.77"
Options: 74-13528-B2 3.62" (70mm)
Suitable for Zone 0, 1, or 2 explosion proof General Purpose, 3 ft. cable (92mm)

-400 to 4000F high temperature 74-13528-DBA


Quick disconnect connector General Purpose, Micro Connector
Underwater capabilities
English or Metric threads
Model 73 Model 74

Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options

Repeatability: .002" (.05mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT 2 303 stainless steel
SAA Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires, rated at
sawtooth surface configuration O O
221OF (105OC) 600V UL / CSA listed
(rated 2,000 PSI) (Sensing 2 High temperature to 400 F (204 C) with
Response Time: 8 milliseconds Sensing Range: Approx. 2 Side entry with Teflon A2 36" (914 mm)
must be 3) TeflonTM insulated leads (Wiring must be A3 72" (1829 mm)
Form: SPDT, Form C .100” (2.5 mm) end sensing (2,000 PSI) insulated leads (Model 74)
.
Differential: Approx. 020" (.51 mm) F) A4 144" (3658 mm)
.072” (1.8 mm) end sensing (5,000 PSI) (Approval must be 8) (Wiring
Ratings: Resistive 3 HiPressure - 303 stainless A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
.060” (1.5 mm) end sensing (10,000 PSI) must be F) 3 UL listed explosion proof for Cl I, Div 1 & 2;
Operating Temperature: -40O to 221OF AC DC steel (rated 5,000 PSI) Grps A,B,C,D; Cl II, Div 1 & 2, Grps E-G;
5 Bottom of enclosure Cable 18 Gauge ( .250" dia.) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA listed
(-40O to 105OC). HiTemp to 400OF (204OC) Volts Amps Volts Amps
Sensing Range with Target Magnet: (Sensing must be 4) (Approval Cl III (Model 73 ) (Lead seal req'd within B2 36" (914 mm)
120 4 24 3
up to .35” (9 mm) must be 2, 7, 8, or 9) 18") B3 72" (1829 mm)
240 2 48 1.25
B4 144" (3658 mm)
73 Model 73 480 * 125 0.5 4 CSA certified explosion proof for Cl I, Div 1;
3 Standard sensing - approx. .100" B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
5
/8" (16 mm) dia. x 35/8" (92 mm) 250 0.5 4 HiPressure - 303 stainless Grps A,B,C,D; Cl II, Div 1; Grps E-G; Cl III
(3 mm) end sensing (Enclosure steel (rated 10,000 PSI)
long with 5/8"-18 UNF x 17/8" (Model 73) (Lead seal req'd within 18") Water Resistant 18 Gauge (3 cond .250" dia; 4 cond .450" dia) PVC cable rated at 176OF (80OC) 300V
(48 mm) threads and 1/2" NPT must be 2 or 6) (Sensing must be 5) (Approval with water-resistant squeeze connector. (Model 74)
4 HiPressure sensing - approx. 6 CSA certified Cl I, Div 2; Grps A,B,C,D;
conduit hub 1 Single Pole Double Throw (Form C) must be 2, 7, 8, or 9) C2 36" (914 mm)
Cl II, Div 2; Grps E-G; Cl III (Model 73)
.072" (2 mm) end sensing C3 72" (1829 mm)
(Wiring must be A, B, or F) (Lead seal C4 144" (3658 mm)
73M Model 73 (Enclosure must be 3 and Approvals 6 316 stainless steel req'd within 18") C_ _ _ Lengths greater than 144" (Specify length in feet (e.g. C150 = 150 ft. of cable))
M18 x 1.5 external metric thread must be 2, 7, 8, or 9) (rated 2,000 PSI)
5 HiPressure sensing - approx. 7 CSA certified General Purpose
Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case ground)
74 Model 74 .060" (2 mm) end sensing 8 UL listed General Purpose (Approvals must be 7 or 8) Refer to pp. 93-104 for mating cable assemblies and Aura Light Adapters.
5/8" (16 mm) dia. x 23/4" (70 mm)
(Enclosure must be 4 and Approvals
long with 5/8"-18 UNF x 17/8" 9 CENELEC: EExdIIC T6 Zone 1. Mini-change® Micro-change®
must be 2, 7, or 8)
(48 mm) threads. No conduit hub (EN 50 014 & EN 50 018, BASEEFA DCA 3 - pin Mini-change® type DBA 3 - pin Micro-change® type
Certificate Ex89C1233X) (Model 73) DCD 4 - pin Mini-change® type DBD 4 - pin Micro-change® type
74M Model 74 (Wiring must be A or B) DCG 5 - pin Mini-change® type DBG 5 - pin Micro-change® type
M18 x 1.5 external metric thread A SAA: Ex s IIC T6 IP65; Cl I Zone 1 & 2; EX
Extended Sensing Range with Need Accessories? SubSea Underwater Connector (Model 73)
S IIC T6 IP65; Cl I Zone 0; DIP Cl II (Intrin- 3DD 3 pin, certified not to leak underwater
External Target Magnets
(See Accessories for External Target Magnets) See pp. 93-104 for: sically safe with entity approved barrier. 4DD 4 pin, certified not to leak underwater
Install per NEC Article 501.) (Wiring must be 3DE 3 pin right-angle, certified not to leak underwater
Form C - SPDT Range Extending 4DE 4 pin right-angle, certified not to leak underwater
A)
Magnet Sensing Differential Target Magnets
Mounting Brackets B SAA: High Temp 350OF (176OC): EX S IIC
AMP3 .20" .25" HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF (250oC) 600V
AMS4 .35" .15" Connectors and more! T6 IP65; Cl I Zone 1 & 2; EX S IIC T6 IP65; UL / CSA listed (Approval must be 2, 3, 4, 6, 7, 8 or B)
AMS7 .20" .05" Cl I Zone 0; DIP Cl II (Intrinsically safe with F2 36" (914 mm)
Ordering Guide entity approved barrier. Install per NEC F3 72" (1829 mm)
Fill in the boxes to create your Article 501.) (Wiring must be F) F4 144" (3658 mm)
‘ordering number.’ F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))

Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options

42 - - 43
1
Models 75, 76 & 77 502.969.8000 Leverless Limit Switches

Round Switches
1.00" (25mm)
Models 75, 76 & 77 5/8"-18 UNF-2A
A.F. ON HEX 5/8"-18 UNF-2A
THREADS
THREADS

GO Switch Models 75 and 76 are the same as


1.15"
models 73 and 74, only slightly longer with more (29mm)

thread surface and therefore more adjustability.


2.81"
Model 77 is the longest and largest option in the 70 2.81"
(71mm) (71mm)

series family. 3.19"


1/2"-14 NPT
3.19"
CONDUIT
(81mm) OUTLET (81mm)

Features: Model 75
4.31"
(110mm)
Model 76
SPDT 4A contacts 1.00" (25mm)
A.F. ON HEX
Intrinsically Safe 3/4"-16 UNF-2A
THREADS
-400 to 2210F operating temperature .625"
(16mm)
Options:
Suitable for Zone 0, 1, or 2 explosion proof 1.15"
(29mm)

-400 to 4000F high temperature


Quick disconnect connector
Underwater capabilities 1.88"
(48mm)
2.81"
(71mm)
1/2"-14 NPT
CONDUIT OUTLET
English or Metric threads
5.81"
Model 77 (148mm)

Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options

Repeatability: .002" (.05mm) typical Contact Material: Palladium silver with Target Material: Ferrous steel Conduit Outlet: 1/2" NPT 2 303 stainless steel SAA Lead Wires 18 Gauge (.110" dia) potted-in PVC insulated AWM / TEW stranded lead wires, rated at
221OF (105OC) 600V UL / CSA listed
sawtooth surface configuration
(rated 2,000 PSI) (Sensing A2 36" (914 mm)
Response Time: 8 milliseconds Sensing Range: 2 Side entry with Teflon 2 High temperature to 400OF (204OC)
must be 3) A3 72" (1829 mm)
Form: SPDT, Form C .100” (2.5 mm) end sensing (2,000 PSI) insulated leads (Model 76) with TeflonTM insulated leads (Wiring A4 144" (3658 mm)
Differential: Approx. .020" (.51 mm) .072” (1.8 mm) end sensing (5,000 PSI) (Approval must be 8) (Wiring must be F) A_ _ _ Lengths greater than 144" (Specify length in feet (e.g. A150 = 150 ft. of leads))
Ratings: Resistive .060” (1.5 mm) end sensing (10,000 PSI) 3 HiPressure - 303 stainless 3 UL listed explosion proof for Cl I, Div
must be F)
Operating Temperature: -40O to 221OF steel (rated 5,000 PSI) 1 & 2; Grps A,B,C,D; Cl II, Div 1 & 2, Cable 18 Gauge (.250" dia.) potted-in PVC cable, rated at 176OF (80OC) 300V, UL / CSA listed
(-40O to 105OC). HiTemp to 400OF (204OC) AC DC
(Sensing must be 4) (Approval B2 36" (914 mm)
Sensing Range with Target Magnet: Grps E-G; Cl III (Model 75 & 77) (Lead seal
Volts Amps Volts Amps 5 Bottom of enclosure B3 72" (1829 mm)
120 4 24 3 up to .35” (9 mm) must be 2, 7, 8, or 9) req'd within 18")
75 Model 75 B4 144" (3658 mm)
5/8" (16 mm) dia. x 45/16" (110 mm)
240 2 48 1.25 4 CSA certified explosion proof B_ _ _ Lengths greater than 144" (Specify length in feet (e.g. B150 = 150 ft. of cable))
480 * 125 0.5 3 Standard sensing - approx. .100" 4 HiPressure - 303 stainless for Cl I, Div 1; Grps A,B,C,D; Cl II,
long with 5/8"-18 UNF x 213/16" 250 0.5
(3 mm) end sensing (must be 2 or 6) steel (rated 10,000 PSI) Div 1; Grps E-G; Cl III (Model 75) (Lead Water Resistant 18 Gauge ( .250" dia.) PVC cable rated at 176OF (80OC) 300V with water-resistant
(71 mm) threads and 1/2" NPT
(Sensing must be 5) (Approval seal req'd within 18") squeeze connector. (Model 76) UL / CSA listed
conduit hub
4 HiPressure sensing - approx. 6 CSA certified Cl I, Div 2; Grps C2 36" (914 mm)
1 Single Pole Double Throw (Form C) must be 2, 7, 8, or 9)
A,B,C,D; Cl II, Div 2; Grps E-G; Cl III C3 72" (1829 mm)
75M Model 75 .072" (2 mm) end sensing
(Model 75 & 77) (Wiring must be A, B, or F) C4 144" (3658 mm)
M18 x 1.5 external metric thread (Enclosure must be 3 and Approvals 6 316 stainless steel C_ _ _ Lengths greater than 144" (Specify length in feet (e.g. C150 = 150 ft. of cable))
(Lead seal req'd within 18")
must be 2, 7, 8, or 9) (rated 2,000 PSI)
76 Model 76 7 CSA certified General Purpose Quick Disconnect Male Quick Disconnect only, potted-in connector. (CSA requires a case ground)
5/8" (16 mm) dia. x 3 3/16" (81 mm)
5 HiPressure sensing - approx. 8 UL listed General Purpose (Approvals must be 7 or 8) Refer to pp. 93-104 for mating cable assemblies and Aura Light Adapters.
long with 5/8"-18 UNF x 213/16" .060" (2 mm) end sensing 9 CENELEC: EExdIIC T6 Zone 1.
(71 mm) threads. No conduit hub Mini-change® Micro-change®
(Enclosure must be 4 and Approvals (EN 50 014 & EN 50 018, BASEEFA DCA 3 - pin Mini-change® type DBA 3 - pin Micro-change® type
must be 2, 7, or 8) Certificate Ex89C1233X) (Model 75 DCD 4 - pin Mini-change® type DBD 4 - pin Micro-change® type
76M Model 76 & 77) (Wiring must be A or B) DCG 5 - pin Mini-change® type DBG 5 - pin Micro-change® type
M18 x 1.5 external metric thread
A SAA: Ex s IIC T6 IP65; Cl I Zone 1 &
2; EX S IIC T6 IP65; Cl I Zone 0; DIP SubSea Underwater Connector (Models 75 & 77)
77 Model 77 Extended Sensing Range with Need Accessories? 3DD 3 pin, certified not to leak underwater
3 4 External Target Magnets Cl II (Intrinsically safe with entity approved
/ " (19 mm) dia. x 5 13/16" (148 mm) 4DD 4 pin, certified not to leak underwater
(See Accessories for External Target Magnets) See pp. 93-104 for: barrier. Install per NEC Article 501.)
long with 3/4"-16 UNF x 213/16" 3DE 3 pin right-angle, certified not to leak underwater
(Wiring must be A) (Model 75) 4DE 4 pin right-angle, certified not to leak underwater
(71mm) threads. Form C - SPDT Range Extending
Magnet Sensing Differential Target Magnets B SAA: High Temp 350OF (176OC): EX S IIC
Mounting Brackets T6 IP65; Cl I Zone 1 & 2; EX S IIC T6 HiTemp Leads 18 gauge (.070" dia. potted-in TeflonTM insulated leads rated at 482oF (250oC) 600V UL /
AMP3 .20" .25" CSA listed (Approval must be 2, 3, 4, 6, 7, 8 or B)
Connectors and more! IP65; Cl I Zone 0; DIP Cl II (Intrinsically
AMS4 .35" .15" F2 36" (914 mm)
safe with entity approved barrier. Install per
Ordering Guide AMS7 .20" .05"
NEC Article 501.) (Wiring must be F) (Model
F3 72" (1829 mm)
F4 144" (3658 mm)
Fill in the boxes to create your 75) F_ _ _ Lengths greater than 144" (Specify length in feet (e.g. F150 = 150 ft. of leads))
‘ordering number.’
Model Contact Form Sensing Range Outlet Position Enclosure Material Approvals Wiring Options