Quick Guide CAN-Sens-D

05-2022

Board / Power Supply / Display

DISPLAY
CAN OPT
ADDRESS 12

CAN

(+)
(-)
24 Vdc
6
5
4
CON 1 CON 2 CON 3
3
2

1
STANDBY

CON 5 CON 7
PULSE 1
PULSE 2
24V out

EARTH

CAN H

CAN H
PINK

CAN L

CAN L
GRAY
GND

GND

GND
24V

24V
GREEN
YELLOW
BROWN

Counter
CONTROL CAN CAN WHITE
Counter 1

Counter 2
Power out

CAN-Local

CAN-Local
CAN-Egg /

CAN-Egg /
Power

Power
Standby

(N)
(L)
Earth

100-240
Vac

CAN-Sens-D EggXact wiring

DISPLAY
CAN OPT
ADDRESS 12

CAN

6
5
4
CON 1 CON 2 CON 3 #1
3
2
1
STANDBY

CON 4 CON 5
PULSE 1
PULSE 2
24V out

EARTH

PINK
CAN H

CAN H
CAN L

CAN L
GND

GND

GND

GRAY
24V

24V

GREEN
CONTROL CAN CAN YELLOW
BROWN
WHITE

HA90064302
CAN-Local connection (max 16 counters)

CAN-IO-(X) CAN-Sens-D #1 CAN-Sens-D #N


CAN OPT CAN OPT
ADDRESS 12 ADDRESS 12

JP (x)
CAN-Local
(H)
(X) (X)

CAN-Local

CAN-Local (L)

24V
(X) (X)

CON 1 CON 2 CON 3 CON 1 CON 2 CON 3


GND
STANDBY

STANDBY
PULSE 1
PULSE 2

PULSE 1
PULSE 2
24V out

24V out
EARTH

EARTH
CAN H

CAN H

CAN H

CAN H
CAN L

CAN L

CAN L

CAN L
GND

GND

GND

GND

GND

GND
24V

24V

24V

24V
CONTROL CONTROL
max.
30mm

Twisted pair CKY-2x2x0.5mm2 +scr Twisted pair CKY-2x2x0.5mm2 +scr

CAN-Egg connection (max 64 counters)

CAN-IO-12-6 CAN-Sens-D #1 CAN-Sens-D #N


CON 5 CAN OPT CAN OPT
ADDRESS 12 ADDRESS 12
1

JP2
2

CAN-Egg
CAN-Egg (H)
3

CAN-Egg (L)
4
5
6

24V
7

CON 1 CON 2 CON 3 CON 1 CON 2 CON 3


GND
8
9 10

STANDBY

STANDBY
PULSE 1
PULSE 2

PULSE 1
PULSE 2
24V out

24V out
EARTH

EARTH
CAN H

CAN H

CAN H

CAN H
CAN L

CAN L

CAN L

CAN L
GND

GND

GND

GND

GND

GND
24V

24V

24V

24V

CONTROL CONTROL
max.
30mm

Twisted pair CKY-2x2x0.5mm2 +scr Twisted pair CKY-2x2x0.5mm2 +scr

CAN-Bus termination

CAN-Sens-D #1 CAN-Sens-D #2 CAN-Sens-D #(X)


CAN-IO-(X)
JP (x)
CAN-Local / Egg “off” “off” “on”
SW2 SW2 SW2

HA90064302
Address dipswitch setting

#1 #2 #3 #4 #5 #6 #7 #8

#9 # 10 # 11 # 12 # 13 # 14 # 15 # 16

# 17 # 18 # 19 # 20 # 21 # 22 # 23 # 24

# 25 # 26 # 27 # 28 # 29 # 30 # 31 # 32

# 33 # 34 # 35 # 36 # 37 # 38 # 39 # 40

# 41 # 42 # 43 # 44 # 45 # 46 # 47 # 48

# 49 # 50 # 51 # 52 # 53 # 54 # 55 # 56

# 57 # 58 # 59 # 60 # 61 # 62 # 63 # 64

Dipswitch 7 and 8 function

Number of counters Pulse out


CAN OPT CAN OPT CAN OPT CAN OPT
ADDRESS 12 ADDRESS 12 ADDRESS 12 ADDRESS 12

1x 2x 1x 5x

Standby connection

CON 1 Standby:
Always connect !!!

Prevents:
STANDBY

Counting of rolling eggs when egg belt has stopped


PULSE 1
PULSE 2

24Vout
24V out

EARTH

“Phantom” counting (bugs / feathers)


GNDout
GND

#1
Frequency converter:
#2 Minimize Ramp Down time (0.01 sec)
Activate DC-Hold function of Frequency converter
Standby

HA90064302
EggXact-XX-D (max. one counter)

= CAN-Sens-D
max. 2m / 6.56ft
= EggXact-12/80 (Only indoor and in pulse mode max 100m / 328ft)

EggXact-XX-D CAN-Local communication

Fortica
CAN-Local CAN-Local

= CAN-Sens-D

= EggXact-12/80

Signal Led

HA90064302