KA-1033

TWIN TMA 700/850

Designed to be deployed in co-located 700 and 850MHz networks the


Kaelus KA-1033 provides gain in the 700MHz uplink and in the 850MHz
uplink, using independent LNAs per band and per channel.
FEATURES
Improved base station sensitivity through gain in 700MHz and
850MHz band
Suitable for WCDMA, LTE and 5G NR signals
Independent gain control for each LNA
Fail safe bypass mode with lightning protection
High linearity and low noise performance
Rejection of DTV and STL Frequencies

TECHNICAL SPECIFICATIONS
BAND 700 850

DOWNLINK
Passband 768 - 803MHz 859 - 890MHz
Insertion loss 0.4dB typical, 0.8dB maximum 0.45dB typical, 0.8dB maximum
Return loss 20dB typical, 18dB minimum
Maximum input power 60W (LTE/NR) 80W (WCDMA/LTE/NR)

Intermodulation products -150dBc maximum with 2 x 20W carriers


Measured at ANT, in RX band, IM3
65 ± 10ns@768MHz 75.5± 10ns@859MHz
60 ± 5ns@770.5MHz 60 ± 5ns@861.5MHz
50 ± 5ns@775.5MHz 45 ± 5ns@866.5MHz
47 ± 5ns@780.5MHz 40 ± 5ns@872MHz
Absolute Group Delay 47 ± 5ns@785.5MHz
37 ± 5ns@877MHz
50 ± 5ns@790.5MHz 36 ± 5ns@882.5MHz
55 ± 5ns@795.5MHz 38 ± 5ns@887.5MHz
70 ± 5ns@800.5MHz 42 ± 10ns@890MHz
90 ± 10ns@803MHz

Rev 5 Jun 30 2022 KA-1033


© Kaelus 2022. All rights reserved Page 1 Contact Us: +1 303 768 8080 | +61 (0) 7 3907 1200 | www.kaelus.com
UPLINK
Passband 713 - 748MHz 814 - 845MHz
Gain 17dB 15.5dB
Gain variation ±1dB maximum
Return loss 18dB minimum
Bypass return loss 12dB minimum
Bypass loss 2.6dB typical, 3.0dB maximum 3.3dB typical, 4.6dB maximum
Noise figure 1.2dB typical, 1.6dB maximum 1.5dB typical, 2.2dB maximum
Output IP3 +32dBm typical
Maximum input power with no +24dBm maximum
damage
P1dB +16dBm minimum
RX in filter rejection @ 50 - 48dB minimum, 60dB typical
694MHz (DTV)
105 ±15ns@713MHz 260 ± 20ns@814MHz
92 ±10ns@715.5MHz 190 ±10ns@816.5MHz
80 ± 5ns@720.5MHz 142 ± 5ns@821.5MHz
77 ± 5ns@725.5MHz 129 ± 5ns@827MHz
Absolute Group Delay - LNA on 77 ± 5ns@730.5MHz 131 ± 5ns@832MHz
80 ± 5ns@735.5MHz
150 ± 5ns@837.5MHz
90 ± 5ns@740.5MHz 215 ± 15ns@842.5MHz
110 ± 10ns@745.5MHz 366 ± 25ns@845MHz
135 ± 20ns@748MHz

ELECTRICAL
Impedance 50Ohms

System attenuation 60dB minimum @50-694MHz (DTV)


25dB minimum @847.5-852 (STL) LNA on

POWER SUPPLY (NON AISG MODE)


With DC applied to one or two BTS ports, all LNAs are switched on in the TMA. See the "AISG mode of operation" for supply current vs voltage.
DC supply voltage +8.5 to +30V DC, case is DC ground

AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0 FRAMES)


AISG signals can be applied to either BTS ports. The TMA unit switches to AISG mode when valid frames are detected on either BTS1 or BTS2. All LNAs
take DC power from the port with the AISG frames or, if DC is present on both ports power will be supplied equally between the ports. Each LNA is
controlled uniquely by its sub-unit number.
DC supply voltage +8.5V to +30V DC
AISG version 2.0
Supply current, AISG mode 430mA @ 8.5V, 135mA @ 30V typical
AISG connector, current rating IEC60130-9, 8-pin female, < 4A peak, 2A continuous, pin 6
Field firmware upgradable Yes
AISG pass through to antenna Yes
port

Rev 5 Jun 30 2022 KA-1033


© Kaelus 2022. All rights reserved Page 2 Contact Us: +1 303 768 8080 | +61 (0) 7 3907 1200 | www.kaelus.com
ANTENNA AISG AND DC
When DC is applied to the TMA, it is initially switched through to ANT1 port. If a nominal DC current is measured (<2A), DC and AISG are passed through
the ANT1 port for antenna AISG control and AISG OUT - 8PIN connector is disabled. If a short circuit is present (>4A) the ANT1 port is disabled and DC and
AISG is passed to the AISG OUT port. If a nominal load is measured on the AISG OUT, DC and AISG are passed out the AISG OUT port for antenna AISG
control through an external AISG cable. If the AISG OUT port is also a short circuit,the AISG OUT port is also disabled. After AISG routing is determined
monitoring of the DC and AISG continues, a short circuit on either enabled port will shut down the affected port, if ANT1 port is shut down DC and AISG will
be routed to the AISG OUT port if available.
Expected load Expected load
Mode of Operation on on Assumption Condition
ANT1 port AISG OUT port

50ohms termination (ie Any load possible DC and AISG will be


AISG capable device supplied to ANT1 port. DC
ANT AISG control via ANT1 port antenna) or open circuit Short preferred
See Note 1 See Note 2 available via RF port and AISG is disabled from
the AISG OUT port

50ohms termination (ie AISG capable device DC and AISG will not be
ANT AISG control via AISG OUT Short circuit antenna RET cable/device) available via external RET supplied to ANT 1 port. DC
port or Open circuit cable and AISG are supplied to
the AISG OUT port
AISG disabled for both
Fault or short circuit ANT1 and AISG OUT port.
ANT AISG disabled Short circuit Short circuit Note TMA continue to
present on AISG circuits
operate while DC is applied
to BTS ports
Note1: Expected current drawn <2A. If the current rises above 2A but remains below 4A, the current will continue to be monitored for a further 15 seconds. If
it remains above 2A after 15 seconds the DC/AISG will be disabled
Note 2: A set of jumper PINs has been added to the AISG OUT port to force the voltage on the AISG connector pins to remain at 0V and disable the AISG
OUT port if not being used. The jumper PINs are fitted by default at the Kaelus factory and must be removed if an external AISG cable is used.
Note 3: To re-enable the DC/AISG feed on ANT1 and/or AISG port, the TMA will need to be re-started.

ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus.
Temperature range -10ºC to +55ºC | +14°F to +131°F
Ingress protection IP67
Altitude 2,600m | 8,530ft
Lightning protection IEC61312-1, RF: ±5kA maximum (8/20us), AISG: ±2kA maximum (8/20us)
MTBF >1,000,000 hours
EMC:EN 301 489-50
Compliance ETSI EN 300 019-1-4 class 4.1
RoHS
NEBS Standard GR-487-CORE

MECHANICAL
Dimensions H x D x W 420 x 295 x160 mm | 16.5 x 11.6 x 6.3 in
Weight 20kg | 44lbs
Finish Painted, light grey (RAL 7035)
Connectors DIN 4.3-10 (F) x 4, AISG (F) x 1
Mounting Poll/wall bracket supplied with two U-bolt clamps 55-155mm diameter poles

ORDERING INFORMATION
PART NUMBER DESCRIPTION
KA-1033-2132 TWIN TMA 700/850, 2 ANT, ANT AISG

Rev 5 Jun 30 2022 KA-1033


© Kaelus 2022. All rights reserved Page 3 Contact Us: +1 303 768 8080 | +61 (0) 7 3907 1200 | www.kaelus.com
ELECTRICAL BLOCK DIAGRAM

Rev 5 Jun 30 2022 KA-1033


© Kaelus 2022. All rights reserved Page 4 Contact Us: +1 303 768 8080 | +61 (0) 7 3907 1200 | www.kaelus.com
MECHANICAL BLOCK DIAGRAM

Rev 5 Jun 30 2022 KA-1033


© Kaelus 2022. All rights reserved Page 5 Contact Us: +1 303 768 8080 | +61 (0) 7 3907 1200 | www.kaelus.com

You might also like