REVISION No. 0
CONFIDENTIALITY
The information contained in this document is confidential to Kuwait Integrated Petroleum Industries Company.
Accordingly, copyright for this document is retained with KIPIC and no copying in any format of this document is
permitted without a written permission from KIPIC - Management.
Signatories
Approved by :
JOB TITLE
• -.......;::)dlll---===~--#--· irf+
Mohammed Mansour AI-Ajmi Ali Mohammed AI-Ajmi
Manager, Maintenance Group, AI-Zour Refinery Manager, Operation Group, AI-Zour Refinery
KIPIC
a.Lo l.!u.o.J I ii.!,-1 gJ-i.!.J I
~ µ . J I Jg.J...l.+JI o....w....w,;µ, wlSJ-W ,p....:,J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
Revision History
Mohammed AlamDar
First issue of the Abdullah M AI-Jazzaf Ahmed AI-Khaldi Mohammed AI-Ajmi
0 Temporary Piping /
29/ 03/2018
Hose Connections
Procedure
1
To be i
Master Copy
2 MANAGERS
Page
Rev. No. Description of Amendment Approved by Effective Date
No.
KIPIC
a.Lo~I a..!,,lg.J-4J I
a...µ...Jg...5..JI Jg_µ....µI Q...W..JJ.Jg._.o ulSJ-.W <.S~!
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
TABLE OF CONTENTS
1.0 PURPOSE 4
2.0 CUSTODIAN 4
3.0 REVISION 4
4.0 DEFINITIONS 4
5.0 REFERENCE 5
6.0 SCOPE 5
13.0 TRAINING 15
KIPIC
a.Lo l!u.o.J I 0./,J gJJ:..µ I
CL,!-:i...i<;µ..J I Jg,-4..J I 6....w....wsµ, u lSJ-W ._s:,._:,J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corpora ti on
1.0 PURPOSE
The purpose of this procedure is to ensure safety of personal / equipment while making
temporary pipe / hose connection in a Refinery. This procedure is mandatory to:
a. Establish the necessary requirements to ensure that the connection can be made safely.
b. Ensure that the connection will not violate any of the Refinery safety and environmental
parameter limits.
c. Provide a record and control of such connections.
2.0 CUSTODIAN
3.0 REVISION
4.0 DEFINITIONS
Temporary Piping:
Metallic piping / tubing / hoses & rubber hoses / prefabricated pipe assemblies including their
combinations that are generally used in the Refinery.
Manifolds, piping assemblies which have been fabricated according to the standard engineering
practice and have Standard I&C valid acceptance for use.
Plant Modification Procedure / MOC:
Procedure followed in a Refinery for providing new facilities/ modifying existing facilities
permanently. Any temporary connection that is required for more than 30 Calendar
days shall be subjected to Plant Modification Procedure / Management of Change
(MOC).
oJ.o~I 0,!-19J4ll wld.lz:>.l.l a,w~I ~_µWI
KIPIC
cU.o l!u...o.J I ~ gJ-L!-11
0...,!-1...iµ.JI JgJ-1-+J I 6-..u.u.u~ wlSJ---W ,s>....:>J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
5.0 REFERENCE
The following procedures should be referred to in conjunctions with this procedure:
6.0 SCOPE
The procedure is applicable to all such temporary connections where operating pressure is
not more than 150 psig (10.54 Kgs/Cm2) and temperature not more than 375°F (190 °C).
In general, the temporary connection shall be provided for a maximum of 30 calendar days.
This time limit shall be waived on a request from Section Head Operations, and with due
risk assessment carried out (If required). The temporary connection may be retained for a
maximum of another 15 days. Beyond this time period, the existing Plant modification
procedure shall be applicable.
The scope of temporary connection shall be divided in to the two following categories
• Medium pressure steam-maximum header pressure of 150 psig (i.e. 10.54 kgs /Cm2).
• Nitrogen Connection from Trailer with a pressure regulator below 150 Psig
to be included.
cil.ofil.o.J I i:4Jgj4.J I u ld..i.=-U ~<;µJI ~_µWI
KIPIC
fil..ol1i..o..JI 0-/,Jg)-i.!.J I
o...,µ....i g...5...J I Jg.J--1...µI 0....U.L...Wg....o uts_µ.t, --s~ !
Kuwalt Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleu m Corporation
These temporary connections are generally used for steam flushing / water flushing / draining
/ gas freeing / cooling / ventilating a confined space / purging while handing over / during
shutdown / commissioning ofprocess equipment.
Check if the connection requires risk assessment or not and if required then the risk assessment
shall be carried out by Section Head, Operations and the report shall be attached with the
request.
These temporary connections are generally used for draining of hydrocarbons / process
items other than the utilities listed in 4 .1 , transferring of material from process equipment to
process equipment / skid mounted equipment and handling of chemicals, the risk assessment for
process line shall be carried out as per KIPIC SWP on Work Permit Risk Assessment Doc.#
HSC-TSSA-06-2029, by the Section Head, Operations and the copy shall be attached with the
request
The following is a list of typical connections that are excluded from the Procedure for
temporary pipe/ hose connections and covered by its own systems / procedures:
• To and from process equipment under operation; Plant modification procedure
is to be followed for providing any temporary connection between equipment
under operation.
• Connections to the fire water system: These are covered by the procedure of SHE
Department.
• Potable water system: No connection shall be allowed between potable water system
and any other system.
• Plant air not to be connected with the BA Sets (Breathing Apparatus).
• Nitrogen connection from trailers with bypassing regulators where pressure exceeds
150 psig (10.54 Kgs/Crn2)
iil.ot!u.o.JI a,µg;4JI ul<=li.o.lJ o,µi~I ~;.w..11
KIPIC
ii.1..olii.o..JI ~g}-1.+JI
C>..,!-l..,i~I Jg.J.-l..+.JI ii...w...u.Jg....o ui'.>J----W ,p....:,J
Kuwait Integrated Petroleum Industries Company
A Subsidiary o f Kuwait Petrol eum Corporation
• Air hose connections for Exhaust fans / Ejectors (Used for equipment ventilation)
I Buffing machines/ Jack Hammers / and for on-stream leak sealing activities.
• Water hosed connections for filling water in the pipe lines / Equipment during hydro
test.
• Pipe I hose connection for de-plugging of any process system.
7.1 Temporary hose connections taken for miscellaneous activities other than process
equipment such as
• For putting off fire by using water / steam hoses
• For providing standby steam water hoses during welding activities and hot works.
• For providing blanketing during flange / gland leaks and smoking, mechanical
seal leaks, insulation smoking to prevent fire. To be regularized within 24 hours by
the temporary pipe I hose connections procedure.
• For general maintenance activities by maintenance crew such as cleaning of filters /
strainers / burners / steam traps / general washing of equipment components & floors etc.
• For carrying out hydro test of piping / equipment, as the pressure may exceed 150
psig (10.54 Kgs/Cm2].
o..Lo liloJ I i4)gJ41 I ul.cU=.U Q,!i.,i~ I o.5J.,WJI
KIPIC
o.J....ol.!u..o.JI 0./,.lgJ-4.l I
~g...5...JI Jg;..J....,.JI 6-w....wg....o ulSJ..-W ,p•..:,J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
The job shall be executed by the Maintenance Supervisor as per the set procedure
and guidelines. A checklist is also provided on the back of the temporary Maintenance
8.6
connection request for Maintenance Supervisors reference. Supervisor
The Area Maintenance Engineer / Safety Engineer / Shift Safety Engineer Area I Shift Safety Engineer &
assigned to operations, shall periodically (decide the audit frequency) audit the Area
8.7
temporary connection request and the execution of connections. Maintenance
Engineer
The temporary connection request copy shall be retained by the issuer and
the executor in a separate box file called "on going temporary connection", Operation / Maintenance
8.8
until the connection removed and then kept in "closed temporary connection" file. Supervisor
Temporary connection to be removed after completion of work or before the due date
whichever is earlier, after obtaining approval from Operation Supervisor using the Operation / Maintenance
8.9
same copies (section 5). Supervisor
Section4.C has provision for allowing an extension of the connection for a maximum Section Head
period of 15 days, provided it is approved by the Section head, Operation by canying /Operations/
8.10
outriskassessment (lfrequired) Maintenance
Supervisor
Afterremovalofthetemporaryconnection, the temporary connection request (issuer
& executor copy) shall be duly closed by issuer and executorlteemtris responsible
Operation / Maintenance
8.11 for restoring the site back to nonnal conditions as prior to making a temporary
Supervisor
connection, such as providing caps/boiler makers etc.
It is the responsibility ofthe Unit Section head / Maintenance Engineer to ensure Unit Section Head /
8.13 that no temporary connections are available beyond the maximum allowed Maintenance
duration. Engineer
cil.olilo.J I ci.J.J 9;4.II u l<:U=JJ o.A!,;µ.)I ~_µWI
KIPIC
a...Lo l!u..oJ I 0./,-1 g)-l.µ I
6...,;..l.ig...5...JI Jg;..J....;.JI o....w....wµ
Kuwait Integrated Petroleum Industries Company
A Subsidiary o f Kuwait Petroleum Corporation
ulSJ-W -5:,..;,J
9.3 The Issuer shall fill the necessary requirements in Section 1,2 and 3, and clearly indicate Operation
the duration oftemporaiy connection in Section 4. B Supervisor
The Unit Section Head shall call for a Risk Assessment(lf Required) to be done prior to
execution of the connection. Based on the criticality of requirement, other
services department Engineers shall be called for Risk Assessment.
9.4 Beyond normal working hours, Shift Controllersha l I conduct the Risk Asses s ment Unit Section Head / Shift
(If Required) with the Shift Safety Engineer and Operations & Maintenance Supervisor. Controller
The same shall be regularized by the Section Head / Maintenance Engineer on the next working
day.
Unit Process Engi neer shal l provide the required process data if any requested by th e Section Unit Process
9.5 Head Engineer
Operations Supervisor/
The temporaiy connection shall be started only after the request is duly signed by both issuer, and Section Head/
9.6
executor. (Section 4) Maintenance
Supervisor
The Maintenance Supervisor shall drop the seco nd copy of th e temporary co nn ection request in Maintenance
9.7 th e Safety box avai lab le at th e Operation shelter / CC R. Supervisor
The job shall be executed by the Maintenance Supervisor as per the set procedures and
guidelines. A checklist is also provided on the back of the temporary connection req uest Maintenance
9.8
for Maintenance Supervisors reference. Supervisor
Area / Shift
The Area Maintenance Engineer / Safety Engi neer / Shift Safety Engineer ass igned to Safety
9.9 operation s, shall periodicall y (decide the audit frequency) audit the temporary connection Engineer & Area
request and th e exec ution of co nn ectio n. Maintenance
Emnneer
Operations/
The temporruy connection request copy shall be retained in a separate box file by the issuer
9.10 Maintenance
and the executors until the connection are removed.
Supervisor
The temporruy connection to be removed after completion of work or before the due date
Operations /
whichever is earlier, after obtaining approval from Operations Supervisor using the same
9.11 Maintenance
copies (section 5).
Supervisor
Section 4.cms puvisioo for allowing an extension of the connection for a period of 15 days,
9.12 Section Head
provided it is approved by Section Head, Operations.
cil.otil.c>J I <4JgJJ.+.II wl.cll=l.l ~~I <>5.)-WJI
KIPIC
a.Loli:i..o.JI 0./,-lg)-i.!JI
6...,f...i...ig...1.JI JgJ..l.+JI 0..J.il..il.liµ, wlSJ..W ..5:i....:,J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
After removal of the temporruy connection, the temporary connection request ( ~ & executor
Operations/
copy) shall be duly closed by issuer adem.i:rSectioo-5fire.m.t:ris responsible for restoring the
9.13 Maintenance
site back to normal conditions as prior to making a temporruy connection. such as providing
Supervisor
caps / boiler makers etc.
Copies of the closed form shall be filed and kept for one month (from the date of removal of Operations /
9.14 connections), by both Operations and Maintenance
Maintenance Supervisors fir future records and reference. Supervisor
Unit Section
It is the responsibility of the Unit Section head / Maintenance Engineer to ensure that no Head
9.15
temporary connection is available beyond the maximum allowed duration. /Maintenance
Engineer
iil.ofilDJ I ",f.19J:i+J I .::, ld..i.o.JJ ",!1,!~ I ~;.w.l I
KIPIC
OJ..o l.ii.o.J I Q./,.1 g}-L!-11
o..+-l-,!g....1...)IJ9)-..1...+..J l o.....w...w~ulSJ...W...s>-...:>J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
Plant and Personnel safety are of utmost importance while carrying out any temporary
connection in the Refinery. Some of the precautions and guidelines to be taken while executing
the temporary connections are listed below: -
• All temporary connection shall be provided only for a maximum of 30 calendar days.
Any Extension beyond the 30 days must be requested by the Section Head, with due
risk Assessment exercise (If Required). The extension can be provided for a maximum of
15 days Any extension beyond this shall be subject to Plant Modification Procedure
• Flexible hoses used for temporary pipe connection should comply with the "Procedure
for Utility stations and hoses care and maintenaoce".
• It should be ensured that valve on either side (Process and utility side) are closed prior to
making the temporary connections.
• All flanged connections to be completely bolted and tightened even though the connection is
temporary.
• Operations and Maintenance personnel shall follow all the safety precautions required,
depending upon the purpose for which the temporary connection is made. i.e. by not
over-pressurizing the line /not over-heating the line / avoiding hammering on steam service /
avoiding corrosiveness of material etc.
• Flexible hose is vulnerable for failure at road crossing and inside battery limit due to vehicle
movement. Therefore, the hoses must be property protected at these locations.
a.l.Dlil<>.II ",!lg;4J I u L<:U=.U o.,µ,i 1¢.JI a.!>J.,IW I
KIPIC
a...Lo ~ I a.i,.lgJ-4.l I
<4-1-.!g...!i...JI Jgµ.µ! o....w...wg...o utS_µi, ,p. ..:,J
Kuwa it Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
• All temporary utility connections to other systems must be equipped with positive isolation
devices and a check valve with bleeders between block valves & check valve (Positive
isolation devices arrangement can be done as per job requirement)
• For Nitrogen services the upstream block valve should be globe valve.
• Prefabricated connection manifolds as above should be kept in all process units and offsite
facilities. The service test has to be done for the prefabricated manifolds to ensure that
there is no passing.
• Electrical Safety aspects (bonding or earthing) to be taken care during risk assessment
• The simplified sketch below shows the minimum requirements for a temporary connection
(For Ex.)
--N-----
cilDl!u.AJI a,µgJ4JI wldl.c.J.J ~~I c:.5,ili.11
KIPIC
a.Lo lil.a.J I a..1,-1 gJ-4.J I
C>....,!--.1.,ig...5..JI Jg_µ...µI CL.W...i.U~ .::.15;....w ,p....:,J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
Responsible
Individual Stan or End
<> Decision Task Control Point
NO
Drop NO C.onduc:t
Section Head /
Temporary Risk
Shift Controller
Connection
YES
Remove YfS
Execute the
Connection i.------'1'-----__,J
Connection
Maintenance
Supervisor NO
YES
NO
o.J.olilo.J I <4)gJ4.11 uu:li=JJ o.A!~I ~_>.WJI
KIPIC
a..Lo l.!u..o.J I a.i,J g}-L+.J I
ii...,;..1..ig...5...JI Jg_j..J....µI a....w....wg...o ulSJ..-W <5>....:>J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
Section
TASKS
Team Safety
Process Head Sup. Supv.
Leaders
Engrs Engr. /Shift (Maint.) (Op.)
Maint.
Controller
IDENTIFICAT ION OF
C C A 1 R
CONNECTION NEEDS
PROVIDING THE C C A R R
REQUIRED
RISK ASSESSMENT I C C R R C
EXTE SION C C A C R
EXECUTING THE
I I I R R
CONNECTION
REMOVAL OF I I I R R
CONNECTION
MAINTA INING I I R R
RECORDS
CONDUCTING R R A I
TRAINING
AUDIT I C R A I I
REVIEW OF R C C C
PROCEDURE
KIPIC
a.Lo liX..o.J I 0./,J g_µ+J I
6....i-J.-.!g...1..)1 Jg_µ...µI 6..J.u...;.uc;µ:, ulSJ----W ._s=>-:>J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
13.0 TRAINING
All personnel involved shall be provided with training regarding the procedure before
implementation of the same. The following topics shall be prime aspects which shall be
covered in the training program:
KIPIC
a...Lo~I o.-1,JgJ-l-!.JI
6...,!...l...ig...1.J I Jg_)..l..µI o...J.JJ..;JJ9-0 ul5.J--.W ..s~J
Kuwait Integrated Petroleum Industries Company
A Subsidia ry of Ku wait Petroleum Corporation
TEMPORARY CONNECTION REQUEST ...·•:• KIPIC KUWAIT INTEGRATED PETROLEUM INDUSTRIES COMPANY
FOR UTILITIES -=, ~g;.u.11 {KIPIC)
1 Exact Location:
D Refinery • LNG D Petrochemical
(Area/ Section/ Unit/ Train/ etc)
2 A. Description pf Work {From - To, Attach sketch if required) :
........................................................................................................................................................................................
....................................................................................................................... Using {Flexible Hose/ Metalic Piping)
B. Purpose of Installation: ..................................................................................................................................
3 Details of Connection:
From (Service) ............. Max operating condition : Pressure in Psig ......... . Temp in °F.........
To (Service) .................. Max operating condition : Pressure in Psig .......... Temp in °F.........
4 A. Issued to (Department/ Division/ Contractor)
.....................................................................................................................................................................................
B. Authorization for initial execution: It is safe to proceed with the connection
Is Risk Assessment required? Yes/ No {If yes, attach Risk Assessment report from Section Head Operations)
From (Date) ....................... To (Date)
Issuer (Supervisor, Operations): Signature ............. Name ................ Emp No .......... Date ............. .
Executor (Supervisor, Maintenance) : Signature ....... Name ....... Emp No .......... Date ..............
C. Authorization for extension
(Attach Risk Assessment report from Section Head Operations)
From (Date) ....................... To (Date)
Issuer (Supervisor, Operations): Signature ............. Name ................ Emp No .......... Date ..............
Approver (Section Head/ ZSC. Operations): Signature ....... Name ....... Emp No ......... . Date ..............
5 Authorization for Closure
The temporary connection is no more required and can be removed.
Issuer (Supervisor, Operations) : Signature ............. Name ................ Emp No ......... . Date ..............
The temporary connection has been removed and conditions are restored to normal
Executor (Supervisor, Maintenance) : Signature ....... Name ....... Emp No .......... Date ............. .
Issuer (Supervisor, Operations): Signature ............ . Name ................ Emp No .......... Date ..............
Origi na I: Executor. First Copy: Issuer, Second Copy: Safety DIAL "_ " IN CASE OF ANY EMERGENCY
o.l.o~I <4)gJ411 wldl=l.J ~~I ~..,i,JI
KIPIC
ii.Lo lii.o...J I a.i,..J gj-1.µ I
6...!----1-19--1-11 Jgµ....µ I 6...J..u....w (µ, wlSJ---.W -5:,__:,J
Kuwait Integrated Petroleum Industries Company
A Subsi d iary of Kuwa it Petroleum Corporation
1 Exact Location:
D Refinery • LNG • Petrochemical
(Area/ Section/ Unit/ Train/ etc)
2 A. Description pf Work (From - To, Attach sketch if required) :
........................................................................................................................................................................................
....................................................................................................................... Using (Flexible Hose/ Metalic Piping)
B. Purpose of Installation: ..................................................................................................................................
If connection to drainage system: • Oily Water Sewer-DX • Process Sewer-DX • Chemical Sewer-DX
3 Details of Connection:
From (Service) ............. Max operating condition : Pressure in Psig .......... Temp in °F.........
To (Service) ........ .......... Max operating condition : Pressure in Psig .......... Temp in °F.........
4 A. Issued to (Department/ Division/ Contractor)
.....................................................................................................................................................................................
D Risk Assessment required (see attachment)
B. Authorization for initial execution: It is safe to proceed with the connection
Attach Risk Assessment report from Section Head Operations
From (Date) ....................... To (Date)
Issuer (Supervisor, Operations) : Signature ............. Name ............... . Emp No ......... . Date ............. .
Approver (Section Head/ ZSC. Operations): Signature ....... Name ....... Emp No ......... . Date ..............
Executor (Supervisor, Maintenance) : Signature ...... . Name ....... Emp No .......... Date ..............
C. Authorization for extension
Attach Risk Assessment report from Section Head Operations
From (Date) ....................... To (Date)
Issuer (Supervisor, Operations) : Signature .... ........ . Name ............... . Emp No .......... Date ............. .
Approver (Section Head/ ZSC. Operations) : Signature ....... Name ....... Emp No .......... Date ..............
5 Authorization for Closure
The temporary connection is no more required and can be removed.
Issuer (Supervisor, Operations) : Signature ............ . Name ................ Emp No .......... Date ..............
The temporary connection has been removed and conditions are restored to normal
Executor(Supervisor, Maintenance) : Signature ....... Name ....... Emp No .......... Date ..............
Issuer (Supervisor, Operations) : Signature ............. Name ................ Emp No ......... . Date ..............
Origi na l: Executor. First Copy: Issuer, Second Copy: Safety DIAL"_" IN CASE OF ANY EMERGENCY
a.1D l!w..l I <4JgJ4.11 wlcl.i..c.JJ Q,!.l.i~I ~ _µW I
KIPIC
a.l.ol1Lo.JI 0./,-lgJ,,l..!.JI
o...,µ.., 9---1-ll Jg;..1....J I ii..J.u...w~ ulSJ--W .s>-=>J
Kuwa it Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation
KIPIC
fil.o 11i.o..J I li/,.J gj.l.µ I
ci..;..1.;~I JgJ--l.-µI o....u,._w,;µ, wlSJ-..W ..s~J
Kuwait Integrated Petroleum Industries Company
A Subsidiary of Kuwait Petroleum Corporation