AMM - A318,A319,A320,A321 - SIF - Rev. num: 10 - 01-May-2023 - Figure 78-30-00-991-... https://w3.airbus.com/1T40/document/610113_SGML_C/toc?itemId=610113_SGML_C_EN...

DEACTIVATION OF THE THRUST REVERSER SYSTEM FOR FLIGHT.


AMM 78-30-00-040-013 - Flowchart Pre SBE 73-0222.
Deactivate the T/R HCU with the storage
lockout pin that is attached to the HCU.

Move the translating sleeve forward until one or the two


actuator rod ends can be put in the mounting brackets.
If only one rod end can be put in the mounting bracket,
Close the fan cowls. the other one must be adjusted.

Measure the distance between the translating


sleeve leading edge and the fan cowl aft edge.

Open the fan cowls and manually


move the translating sleeves to the YES
fully retracted position.

Is the distance Is the translating


within the tolerance? NO sleeve in the fully NO
retracted position?

YES

-Remove the plug from the lockout assembly on the outside of each translating sleeve.
-Remove the lockout pin from the pin stowage bracket assembly on the outside of each translating sleeve.
-Clean the plug and the lockout pin.

Install the lockout pin in the lockout assembly.

Is the lockout pin Do a check of the rigging of the translating sleeve actuators.
correctly installed in the NO Refer to AMM TASK 78-30-00-820-010, Para. 4.C,
lockout assembly? SUBTASK 78-30-00-820-052-A.

YES

Install the plug in the pin stowage bracket assembly of each translating sleeve.

Do an operational test of the LVDTs to be sure that they operate correctly on the deactivated thrust reverser.

Check for the ECAM warnings.


PRE SBE 73-0222
End of the procedure.
gc00a5m8424a

N_MM_783000_4_XYZ2_01_02

Figure 78-30-00-991-94200-13-A (SHEET 1/2) - Flowchart


** ON A/C FSN ALL