Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

KEYPLAN:

+280
C +230
B Pool Shower

+280
OVER FLOOW CHANNEL OVER FLOOW CHANNEL GYM
COPPING COPPING +280

PLUNGE
COLD
SUNKEN SEATING

OVER FLOOW CHANNEL


SAUNA

COPPING
A A
OUTDOOR BATHROOM

+280

COPPING COPPING
+280 BAY AREA
JACUZZI
B +280

DINNING AREA
COPPING

+280 +280
C LANDSCAPED AREA
FFL +150

LIVING AREA FAMILY AREA


PATIO

BBQ COUNTER

BAR COUNTER
FFL +150

WINE COOLER

VEGETABLE GARDEN
DINING HALL

LOBBY

UP
1 2 3 4 5 6 7 8 9 10 11
ENTRANCE POWDER
LOBBY ROOM
(DOUBLE HT) SD

DRESS

STORAGE
KITCHEN

CAT MAIN
ENTRANCE

LADDER

LAUNDRY

BED ROOM-1

DIRTY GARAGE
KITCHEN

HELPERS'
BATHROOM

HELPERS' ROOM

DRIVERS' ROOM DRIVERS'


BATHROOM
AUTOMATED GARAGE DOOR

CHEMICALS
1. REQUIRED PH VALUE 7.1 TO 7.4
2. VOLUME OF POOL 75M3 PROJECT :

3. FILTRATION PERIOD Millenium Estates


4. N-BS SALT SYSTEM Villa 91

CLIENT:

2"Ø PVC PIPE DISCHARGE LINE TO JET NOZZLE


2"Ø PVC PIPE FROM BALANCE TANK TO PUMP

2"Ø PVC PIPE FROM JACUZZI DRAIN


2"Ø PVC PIPE FROM VACUUM TO PUMP

2"Ø PVC PIPE DISCHARGE LINE TO POOL INLET


2"Ø PVC PIPE FROM MAIN DRAIN TO PUMP

2"Ø PVC PIPE DISCHARGE LINE TO JET NOZZLE

2"Ø PVC PIPE FROM MAIN DRAIN TO CHILLER PUMP

2"Ø PVC PIPE DISCHARGE LINE TO CHILLER ROOF TOP


2"Ø PVC PIPE FROM JACUZZI DRAIN
2"Ø PVC PIPE BACKWASH LINE TO PBCH

Mr Brian Al Saadi

NOTES :
1. All dimensions are in
millimeters unless
PUMP ROOM SCHEMATIC DIAGRAM stated otherwise.
2. Do not scale off this
drawing.
3. Attached Images in
this package are just
for reference, actual
WATER TREATMENT: site condition may
differ.
1. CIRCULATION RATE --- LESS THAN 4HOURS
LIST OF EQUIPMENTS: 2. FILTRATION SYSTEM --- SAND FILTER
1. SAND FILTER - 650 MM DIA -2NOS
2. FILTRATION PUMP- 2 HP - 2NOS ELECTRICAL: DESERT ROSE
LANDSCAPING L.L.C

3. CONTROL PANEL- WALL MOUNTED- 1NO 1. ALL UNDER WATER LIGHTS ARE OF LOW ahmadmukhtar63@gmail.com
4. TRANSFORMER 12V 200W - 1NOS +971-55-828 6095
VOLTAGE 12V International City, Dubai
5. JET NOZZLE PUMP 2HP - 2NOS U.A.E
2. ALL ELECTRICAL EQUIPMENT ARE
6. CHILLER PUMP 2HP- 1NOS Drawing Title:
PROTECTED WITH ELCB
7. COOLING UNIT - 1NO 3. CONTROL PANEL IS PROVIDED WITH PUMP ROOM
8. N-BS SALT SYSTEM - 1NO SCHEMATIC
EXTERNAL ISOLATOR DIAGRAM

Drawing No:
A-011

✎By: Date:
Rev: Scale:

You might also like