Professional Documents
Culture Documents
b 8453 b59 Assembly Model
b 8453 b59 Assembly Model
10 348 10
A P382
B
6
1) SURFACE PREPARATION FOR GALVANIZATION:
SANDBLASTING SA21/2.
140
FILLET WELD. DIMENSION "S" OF NON-DIMENSIONED FILLET
T1
P773 WELDS SHALL AT LEAST BE EQUAL TO:
S = 0.80 * T for Fy <= 250 MPa
Where: S
6
4 ø 22 A
B
4) THE MINIMUM FILLET WELD SIZE TO BE USED FOR
6 140 6
-
SECTION B B - STRUCTURAL WELDS IS 5mm.
SCALE 1:2
SCALE 1:2
SECTION A A - 5) A MINIMUM SEAL WELD LEG SIZE OF 3mm FILLET WELDS
SCALE 1:2 SHALL BE USED.
6) ALL STRUCTURAL STEEL, INCLUDING PLATFORMS,
HANDRAILS , LADDERS, CAGES, STAIR TREADS, CHEQUERED
PLATES & GRATINGS SHALL BE HOT DIP GALVANIZED ONLY,
EXCEPT CRANES, LIFTING BEAMS, MONORAILS, DAVITS WHICH
ARE GALVANIZED AND PAINTED RAL 1004 SAFETY YELLOW.
FOR DETAILS REFER TO PROJECT SPECIFICATION 14.192.028”
SD-UJV
DOCUMENT STATUS SIGNED DATE
P382
CWP No:A11-WP8.1-020-FI-MC-101
138
60
4 ø 22
OC RE-ISSUED FOR REVIEW RA 15/09/23 ET 15/09/23 EA 15/09/23
OB RE-ISSUED FOR REVIEW UP 30/06/23 ET 30/06/23 EA 30/06/23
OA RE-ISSUED FOR REVIEW UP 01/03/23 ET 01/03/23 EA 01/03/23
39