09-02 PWHT Report

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Job No.

OneBase
Heat Treatment Report Report No. 001

Page: 1 of 1

Heat Treatment Date Chart No.

HICC Procedure No. Furnace/Local - PWHT Local-PWHT

Thermocouple S/N Recorder S/N

Parameters Required Actual

Holding Temp. (°C) 600-650 °C 630 °C

Holding Time (minutes) 60 min.up to 2"(1.5 min./1" over 2") 70 min.

Heating Rate (°C/hr) 220 °C max. 200 °C

Cooling Rate (°C/hr) 220 °C max. 200 °C

Other

S.No. Dwg. No. Spool / Item No. Remarks

LE
P
4

M
5

7
S A
8

10

11

12

A sketch describes the placement of thermocouples must be attached to this report.

Prepared By Approved By Accepted By

Name : Name : Name :

Title : Heat Treatment Operator Title : QC Inspector Title : QC Manager

Signature / Date : Signature / Date : Signature / Date :

WA QC Manual Rev. 0 Date: 17/09/2023 Exhibit No. 09-02


Job No.

Heat Treatment Report


Report No. 001
OneBase
Page: 2 of 2

Placement of Thermocouples Sketch

Thermocouple No. 1

120° 120°

120°
Thermocouple No. 3
Thermocouple No. 2

WA QC Manual Rev. 0 Date: 17/09/2023 Exhibit No. 09-02

You might also like