Structural/Civil Engineers. Project.

GENERAL NOTES
Architect. Client. Title. 1) - Only figured dimensions to be taken from this drawing. Designed by JMM
Job No.

REVISIONS 2) - This drawing is to be read in conjunction with other SE - 702


DESCRIPTION DATE DESCRIPTION DATE Kisonyo Odwori & Associates ROOF DETAILS structural/architectural drawings.
3) - The contractor must confirm all dimensions on site before commensing
Date:
any work.
4) - All dimensions are in millimetres unless specified otherwise. Drawn by DMW
JULY 2021
Boma of Kenya (office) 5) - Concrete cover to reinforcement steel to be:(i) foundation = 50mm.
(ii) columns = 40mm
Drg No.
(iii) beams = 30mm. (iv) slab & staircase = 25mm.
6) - Concrete strength to be class 25/20 for all structural elements Approved by JMM
P.O.BOX 69710 NAIROBI 7) - Concrete strength for blinding to be class 15/40.

02
8) - All steel reinforcement must be approved by the Structural Engineer
before casting.
9) - Surface bed hardcore to be laid in seperately compacted 200mm SCALE
layers on firm approved ground. As Shown
10) - Bearing pressure assumed is 300kN/m2