Professional Documents
Culture Documents
SECTION 12 24 13 - ROLLER WINDOW SHADES
SECTION 12 24 13 - ROLLER WINDOW SHADES
SECTION 12 24 13 - ROLLER WINDOW SHADES
14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
B. Related Requirements:
1. Division 26 Sections for electrical service and connections for motor operators,
controls, limit switches, and other powered devices and for system disconnect
switches for motorized shade operation.
C. Scope Includes:
D. The Owner requires the Contractor to implement practices and procedures to meet the
project's environmental performance goals, which include compliance with the
requirements determined by the Sustainability Consultant’s design documentation
(LEED & WELL), and applicable local authority Green Building Regulation. Specific
project goals that may impact this area of work include, but are not limited to: reduced
impact of construction activities, construction waste recycling, reduction of water and
energy usage, adequate protection for storing materials, use of recycled-content
materials, use of locally manufactured materials, use of low-emitting materials, use of
materials having EPD's, and avoid use of restricted materials. The Contractor shall
ensure that the requirements related to these goals, as defined in individual
specification sections are implemented to the fullest extent. Substitutions, or other
changes to the work proposed by the Contractor or their Subcontractors, shall not be
allowed if such changes compromise the aforementioned environmental goals and
Green Building Regulation compliance.
1. Contractor shall, at all times undertake to ensure that all targeted goals are
achieved. As and when any risks arise that could compromise the achievement of
one or more of the targeted goals, the Contractor shall bring these to the attention
of the Employer's Representative immediately.
A. Product Data: For each type of product indicated. Include styles, material descriptions,
construction details, dimensions of individual components and profiles, features,
finishes, and operating instructions.
C. Shop Drawings: Show location and extent of roller shades. Include elevations,
sections, details, and dimensions not shown in Product Data. Show installation details,
mountings, attachments to other Work, operational clearances, and relationship to
adjoining work.
1. Motorized Shade Operators: Show locations and details for installing operator
components, switches, and controls. Indicate motor size, electrical
characteristics, drive arrangement, mounting, and grounding provisions.
2. Wiring Diagrams: Power, system, and control wiring.
1. Complete, full-size operating unit not less than (406 mm) wide for each type of
roller shade indicated.
2. For the following products:
a. Shade Material: Not less than (305 mm) square section of fabric, from dye
lot used for the Work, with specified treatments applied. Show complete
pattern repeat. Mark top and face of material.
F. Window Treatment Schedule: Include roller shades in schedule using same room
designations indicated on Drawings.
A. Maintenance Data: For roller shades to include in maintenance manuals. Include the
following:
B. Operation and Maintenance (O&M) Manuals: Include component list with the
manufacturer’s reference numbers, descriptions of materials and procedures
forrepairing and cleaning of finishes, and cleaning frequency.
A. Furnish extra materials that match products installed and that are packaged with
protective covering for storage and identified with labels describing contents.
1. Roller Shades: Full-size units equal to 5 percent of quantity installed for each
size, color, and shadeband material indicated, but no fewer than two units.
B. Each shade shall be provided in place and in full operative condition by skilled
workmen experienced and especially trained in the type of installation required, and
who are acceptable to the shade manufacturer.
D. Manufacturer Qualifications: Obtain roller shades through one source from a single
manufacturer with a minimum of twenty years experience in manufacturing products
comparable to those specified in this section.
F. Source Limitations: Obtain roller shades through one source from a single
manufacturer.
A. Deliver shades in factory packages, marked with manufacturer and product name,
fire-test-response characteristics, and location of installation using same room
designations indicated on Drawings and in a window treatment schedule.
B. All delivered shades shall match the final shop drawings and samples. Shades which
are marred, chipped or otherwise damaged shall be replaced.
C. Special care shall be taken in the handling of the shades to avoid their being either
scratched or otherwise defaced during the course of installation. Any materials
showing evidence of such mishandling shall be replaced at no additional cost to the
Owner.
A. Environmental Limitations: Do not install roller shades until construction and wet and
dirty finish work in spaces, including painting, is complete and ambient temperature
and humidity conditions are maintained at the levels indicated for Project when
occupied for its intended use.
B. Field Measurements: Where roller shades are indicated to fit to other construction,
verify dimensions of other construction by field measurements before fabrication and
indicate measurements on Shop Drawings. Allow clearances for operable glazed units'
operation hardware throughout the entire operating range. Notify Architect of
discrepancies. Coordinate fabrication schedule with construction progress to avoid
delaying the Work.
1.9 WARRANTY
A. Installer Warranty: Submit copies of written guarantee signed by the Installer and
Contractor, guaranteeing the shade installation for a period of two (2) years.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
D. Shadebands:
C. Shadebands:
3. Outside Roller:
C. Inside Shadebands:
D. Outside Shadebands:
B. Closure Panel and Wall Clip: Removable aluminum panel designed for installation at
bottom of site-constructed ceiling recess or pocket and for snap-in attachment to wall
clip without fasteners.
C. Side Channels: With light seals and designed to eliminate light gaps at sides of shades
as shades are drawn down. Provide side channels with shadeband guides or other
means of aligning shadebands with channels at tops.
D. Bottom (Sill) Channel or Angle: With light seals and designed to eliminate light gaps at
bottoms of shades when shades are closed.
E. Installation Accessories Color and Finish: As selected from manufacturer's full range.
A. Product Safety Standard: Fabricate roller shades to comply with WCMA A 100.1,
including requirements for flexible, chain-loop devices; lead content of components;
and warning labels.
B. Unit Sizes: Fabricate units in sizes to fill window and other openings as follows,
measured at (23 deg C):
C. Control Equipment: Comply with NEMA ICS 1, NEMA ICS 2, and NEMA ICS 6
with NFPA 70 Class 2 control circuit, maximum 24-V ac or dc.
1. General Requirements:
2. Product(s):
H. Remote Controls: Electric controls with NEMA ICS 6, Type 1 enclosure for recessed
or flush mounting. Provide the following devices for remote-control activation of
shades:
1) Color: White.
I. Limit Switches: Adjustable switches, interlocked with motor controls and set to
automatically stop shade at fully raised and fully lowered positions.
J. Operating Function: Stop and hold shade at three predetermined positions including
open, closed, and one user-programmed position.
1. Group switching with integrated switch control; single face plate for multiple
switch cut-outs.
2. Back-up gear and crank operator for manual operation during power failures with
detachable handle, length required to make operation convenient from floor level.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, areas, and conditions, with Installer present, for compliance with
requirements for installation tolerances, operational clearances, [locations of
connections to building electrical system, ]and other conditions affecting performance
of the Work.
A. Install roller shades level, plumb, and aligned with adjacent units according to
manufacturer's written instructions.
3.3 ADJUSTING
A. Adjust and balance roller shades to operate smoothly, easily, safely, and free from
binding or malfunction throughout entire operational range.
3.5 DEMONSTRATION
END OF SECTION