Professional Documents
Culture Documents
SECTION 11 66 23 - GYMNASIUM EQUIPMENT
SECTION 11 66 23 - GYMNASIUM EQUIPMENT
14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Exercise equipment.
2. Safety pads.
B. Scope Includes:
C. The Owner requires the Contractor to implement practices and procedures to meet the
project's environmental performance goals, which include compliance with the
requirements determined by the Sustainability Consultant’s design documentation
(LEED & WELL), and applicable local authority Green Building Regulation. Specific
project goals that may impact this area of work include, but are not limited to: reduced
impact of construction activities, construction waste recycling, reduction of water and
energy usage, adequate protection for storing materials, use of recycled-content
materials, use of locally manufactured materials, use of low-emitting materials, use of
materials having EPD's, and avoid use of restricted materials. The Contractor shall
ensure that the requirements related to these goals, as defined in individual
specification sections are implemented to the fullest extent. Substitutions, or other
changes to the work proposed by the Contractor or their Subcontractors, shall not be
allowed if such changes compromise the aforementioned environmental goals and
Green Building Regulation compliance.
1. Contractor shall, at all times undertake to ensure that all targeted goals are
achieved. As and when any risks arise that could compromise the achievement of
one or more of the targeted goals, the Contractor shall bring these to the attention
of the Employer's Representative immediately.
D. Related Requirements:
GYMNASIUM EQUIPMENT 11 66 23 - 1
Copyright 2022 Gensler
Gensler 18 November 2022 Riyad Bank HQ, KAFD 1.14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
D. Samples: For each exposed product and for each item and color specified.
1. Pad Fabric: Wall padding minimum 76 mm square, and corner and column
Samples minimum 76 mm long, with specified treatments applied. Mark face of
material.
A. Coordination Drawings: Court layout plans, reflected ceiling plans, and other details,
drawn to scale, and coordinated with ceiling-suspended gymnasium equipment, floor
inserts, game lines, and markers applied to finished flooring, and coordinated with each
other, using input from installers of the items involved:
GYMNASIUM EQUIPMENT 11 66 23 - 2
Copyright 2022 Gensler
Gensler 18 November 2022 Riyad Bank HQ, KAFD 1.14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
a. Luminaires.
b. Air outlets and inlets.
c. Speakers.
d. Sprinklers.
e. Smoke detectors.
f. Acoustical treatments or panels.
g. Access panels.
B. Setting Drawings: For embedded items and cutouts required in other work.
A. Installer Qualifications: An entity that employs installers and supervisors who are
trained and approved by manufacturer.
A. Field Measurements: Verify position and elevation of floor inserts and layout for
gymnasium equipment.
1.8 WARRANTY
GYMNASIUM EQUIPMENT 11 66 23 - 3
Copyright 2022 Gensler
Gensler 18 November 2022 Riyad Bank HQ, KAFD 1.14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
PART 2 - PRODUCTS
C. Pad Coverings: Provide safety pad fabric covering that is fabricated from puncture- and
tear-resistant, PVC-coated polyester or nylon-reinforced PVC fabric, minimum
475-g/sq. m and treated with fungicide for mildew resistance; with surface-burning
characteristics indicated, and lined with fire-retardant liner.
D. Wall Safety Pads: Padded wall wainscot panels designed to be attached in a continuous
row; each panel section consisting of fill laminated to backer board, with visible
surfaces fully covered by seamless fabric covering, free of sag and wrinkles and firmly
attached to back of backer board.
E. Corner Wall Safety Pads: Wall corner pad consisting of minimum 32-mm- thick,
multiple-impact-resistant, closed-cell, polyethylene-foam filler, covered on both sides
and all edges by fabric covering with self-adhesive, hook-and-loop attachment to
exposed face of wall.
GYMNASIUM EQUIPMENT 11 66 23 - 4
Copyright 2022 Gensler
Gensler 18 November 2022 Riyad Bank HQ, KAFD 1.14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
F. Column Safety Pads: Pads covering exposed flange of columns to height indicated,
consisting of minimum 32-mm- thick, multiple-impact-resistant, closed-cell,
polyethylene-foam filler, covered on both sides and all edges by fabric covering with
[backer board and manufacturer's standard anchorage to column] [self-adhesive,
hook-and-loop attachment to exposed face of column].
G. Round Column Safety Pads: Wraparound pads fully covering exposed round column to
height indicated, consisting of minimum 50-mm- thick, multiple-impact-resistant,
bonded polyurethane-foam filler, 96-kg/cu. m density, covered on both sides and all
edges by fabric covering with hook-and-loop attachment to column.
H. Cutout Trim: Manufacturer's standard flanged cutout trim kits for fitting pads around
switches, receptacles, and other obstructions.
1. Color: Gray.
2.3 MATERIALS
B. Support Chain and Fittings: For chains used for overhead lifting, provide Grade 80
heat-treated alloy-steel chains, according to ASTM A391/A391M, with
commercial-quality, zinc-plated steel connectors and hangars.
C. General-Purpose Chain: For chains not used for overhead lifting, provide carbon steel
chain, according to ASTM A413/A413M (Grade 30 proof coil chain or higher grade
recommended by gymnasium equipment manufacturer). Provide coating type, chain
size, number, and installation method according to manufacturer's written instructions.
GYMNASIUM EQUIPMENT 11 66 23 - 5
Copyright 2022 Gensler
Gensler 18 November 2022 Riyad Bank HQ, KAFD 1.14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, areas, and conditions, with Installer present, for compliance with
requirements for court layout, alignment of mounting substrates, installation tolerances,
operational clearances,[ accurate locations of connections to building electrical
system,] and other conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
A. Comply with manufacturer's written installation instructions[ and competition rules for
each type of gymnasium equipment].
B. Install gymnasium equipment after other finishing operations, including painting, have
been completed unless otherwise indicated.
GYMNASIUM EQUIPMENT 11 66 23 - 6
Copyright 2022 Gensler
Gensler 18 November 2022 Riyad Bank HQ, KAFD 1.14
064.1240.000 Interior Design Specification Riyadh, Ar Riyad
Stage 4 - Detailed Design Rev 01 KSA
B. Cutout Trim: Limit cuts in face of padding so that cuts are securely and fully concealed
behind trim-kit flange.
A. Testing Agency: Engage a qualified testing agency to perform tests and inspections.
B. Perform the following tests and inspections with the assistance of a factory-authorized
service representative:
C. Gymnasium equipment will be considered defective if it does not pass tests and
inspections.
3.5 ADJUSTING
3.6 DEMONSTRATION
END OF SECTION
GYMNASIUM EQUIPMENT 11 66 23 - 7
Copyright 2022 Gensler