1.avP14at_AV110XDiaCU2_EN

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Manual

AV 110 X
Cummins

Book ID: 4-P14401CU -EN


AV 110 X
Articulated tandem roller
Cummins Tier 2

Manual
WinGPI - part 1 - Diagnostics
Edition 02/2013 EN
Speed Sw: 10102718_S0018B_P0004B.Tcf
Created by AITC
WARNING!
ATTENTION when using this application!

This application setting changes control unit of machine, and therefore changes
behavior of the machine.

Changes of parameter could cause uncontrollable movements machine and can


cause injury to health or property.

If you have not the necessary knowledge and you are not trained DO NOT
CHANGE!

Moving to the next screens of the program you agree that you are aware of
hazards and risks bonded with the use of this software.
Diagnostics of fault - SPEED

General procedure for diagnosing faults on a machine with system Win GPI.
Perform the computer interconnection by means of a connecting cable (RS 232) into the Susmic socket
on the left corner of cabine (under the cover)- red arrow

Select the required unit (SPEED).


Open program Win GPI - open LOAD TCF – select the correct version of software for actual type of
machine and unit:
Sw: 10102718_S0018B_P0004B.Tcf – ENTER

1
Start -up engine of machine

Information screen: Here we can find actual software version which is recorded in Susmic. The
numbers must agree. If not, close program and change version of software for open comunication.

Software version Software version in


in Laptop Susmic

2
Some units need to enter a PIN (0305)

(All the data show Fault if the machine is not set up)! - ENTER

3
Table is displayed „Speed Control Main Menu“. Select No. ,,0“ – Data screen. (Diagnostic)- ENTER

Data screen: Only In this mode is possible move with the machine and watching actual data from the unit

4
Error table: Select (Shift+E) in Data screen mode – Here we find the actual faults on machine which we
need identify.

Then fix problem, or replace the defective component (After replacing some faulty component is
necessary re-calibrating sensor or adjusting some data.)

Error corresponds to the error code, which flashes red LED on the body of Susmic unit. Orange
lamp in dashboard gauge is no correspond with error codes. Informing only about some error If
flashing.

5
The error codes are reported to the red LED (position 4) on Susmic.

6
7
Notes:

………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………
………………………………………………………………………………………

8
Contact for Technical Support:
e-mail: support.machines@ammann-group.com
mobile: +420 776 667 755

9
Ammann Unternehmungen
Eisenbahnstrasse 25
CH-4901 Langenthal
Phone +41 62 916 61 61

www.ammann-group.com

You might also like