1
Air Gap Capacitive Sensor
Applications
• On-line air gap measurements for:
- generators,
- synchronous condensers, and
- motors
• On-line proximity measurements
• Specified for gaps from 7 to 14 mm (275 to 550 mils)
Features
Description • Range: 2 to 20 mm (80 to 800 mils)
◊
The VM 3.1 Capacitive Sensor is a flat, noncontact type • Used with AGMS or ZOOM Data Acquisition Units, and
sensor which generates the necessary electric field to with the DCC-631 Signal Conditioner
measure the distance between its surface and a target.
The measured signal is sent through a triaxial extension • Highly immune to deposits of carbon dust and oil, and
cable to the AGMS or the ZOOM Data Acquisition Units, strong magnetic fields
the DCC-631 Signal Conditioner, or the LIN-231 • Easy to install on stator wall without removing the
Linearization Module. rotor or poles
Slim design and high immunity make the VM 3.1 a universal • Noncontact, nonintrusive sensor
proximity sensor. Its measuring range, accuracy, and
reliability is unaffected by: deposits of carbon dust, dirt, and • Over 10 years of field experience
oil; strong magnetic fields; high shock vibration; and EMI-RFI.
The VM 3.1 is a passive sensor, with no moving parts or
active electronic elements and is compatible with most
types of conductive and semi-conductive target material.
TOP VIEW
VM 3.1
33.25 mm
(1.30")
220.50 mm (8.68")
VibroSystM reserves the right to change specifications to improve products without notification.
ZOOM® and AGMS® are registered trademarks of VibroSystM Inc.
◊
Patented measuring technology
Applications
• Air gap & proximity measurements in narrow area:
- motors
- generators
- exciters
• Specified for gaps less than 7 mm (275 mils)
Features
• Very low profile: 1.15 mm (45 mils) thickness
Description • Range: 1 to 10 mm (40 to 400 mils)
The VM 3.2 Capacitive◊ Sensor is a flat, noncontact type
• Used with the DCC-632 Signal Conditioner
sensor which generates the necessary electric field to
measure the distance between its surface and a target. • Special cable and calibration available when used
The measured signal is sent through a triaxial extension with the AGMS or ZOOM Acquisition Units
cable to a DCC-632 Signal Conditioner. Special extension
• Highly immune to carbon dust, strong magnetic fields,
cable and modified calibration of the signal conditioning card
vibration and temperature
are required to use the VM 3.2 with the AGMS or the
ZOOM Acquisition Units. • Easy to install on stator wall without removing the
rotor or poles
Its low profile design and high immunity make it ideal for any
proximity measurements in very narrow areas and harsh • Noncontact, nonintrusive sensor
conditions. Its measuring range, accuracy, and reliability
• Over 10 years of field experience
are unaffected by: deposits of carbon dust, dirt, and oil;
strong magnetic fields; EMI-RFI; temperature; and gas
environments including hydrogen.
The VM 3.2 is a passive sensor, with no moving parts or
active electronic elements and is compatible with most
types of conductive and semi-conductive target material.
Dimensions
8.89 mm
(0.35") 35.56 mm
198.78mm (1.40")
(7.82")
41.82 cm
(16.47")
Operation Integral
VM 3.2 Sensor Cable
• Linear Measuring Range 1 to 10 mm standard
,,,,,,,,,,,,,
Glued onto
(40 to 400 mils) Laminations Stator Rotor
• Power Source
Custom ranges available
455 kHz ,,,,,,,,,,,,,
,,,,,,,,,,,,,
Rotor Pole
Core Pole
VibroSystM reserves the right to change specifications to improve products without notification.
ZOOM® and AGMS® are registered trademarks of VibroSystM Inc.
◊
Patented measuring technology
Applications
• On-line air gap measurements for:
- generators,
- synchronous condensers, and
- motors
• On-line proximity measurements
• Specified for gaps larger than 14 mm (550 mils)
and up to 50 mm (2 in.)
DESCRIPTION Features
◊
The VM 5.0 Capacitive Sensor is a flat, noncontact type • Range: 5 to 50 mm (200 to 2000 mils)
sensor which generates the necessary electric field to • Used with AGMS or ZOOM Data Acquisition Units, and
measure the distance between its surface and a target. with the DCC-650 Signal Conditioner
The measured signal is sent through a triaxial extension
cable to the DCC-650 Signal Conditioner, the AGMS or • Highly immune to deposits of carbon dust and oil, and
the ZOOM Data Acquisition Units. strong magnetic fields
Slim design and high immunity make the VM 5.0 a universal • Easy to install on stator wall without removing the
proximity sensor. Its measuring range, accuracy, and rotor or poles
reliability are unaffected by: deposits of carbon dust, dirt, and • Noncontact, nonintrusive sensor
oil; strong magnetic fields; high shock vibration; and EMI-RFI.
• Over 10 years of field experience
The VM 5.0 is a passive sensor, with no moving parts or
active electronic elements and is compatible with most
types of conductive and semi-conductive target material.
TOP VIEW
VM 5.0
80.00 mm
(3.15")
268.00 mm (10.56")
285.50 mm (11.24")
3.46 mm
(0.14") SIDE VIEW 5.00 mm (0.20")
VM 5.0
,,,,,,,,,,,,
GENERAL SPECIFICATIONS Installation OVER RECESSED WEDGES
Operation ,,,,,,,,,,,,
Glued to
Rotor Pole
VM 5.0
laminations Sensor
• Linear Measuring Range 5 to 50 mm standard
Integral
(200 to 2000 mils) Cable
Custom ranges available Laminations Wedge
• Power Source
• Frequency Response
455 kHz
Limited by the conditioner
Stator
Core
Rotor
Pole
,,,,,,,,,,,,
,,,,,,,,,,,,
• Interchangeability ±5% ,,,,,,,,,,,,
Spacers
glued to
laminations
Rotor Pole
VM 5.0
Sensor
Environmental Sensor
• Temperature Range 0° to 125°C Laminations Wedge
(32° to 260°F) SIDE VIEW OVER PROTRUDING WEDGES
• Magnetic Field Up to 1.5 tesla
[50 Hz or 60 Hz]
• Dust and Oil Dimensions
Contamination No effect • Height 285.50 mm (11.24 in.)
• Width 80.00 mm (3.15 in.)
Connection • Thickness 3.46 mm (0.14 in.)
• Integral Cable Type Teflon coaxial • Clearance 5.00 mm (0.20 in.)
- Connector Male SMA
1
- Length 50.0 cm (19.7 in.) Custom made measuring ranges are also available
2
• Extension Cable Type Belden Triaxial With standard DCC-650 Signal Conditioner
- Connectors
with DCC-650 Female SMA and ground lug
on sensor end;
Male bayonet triaxial on
DCC- conditioner end
with AG or ZM-DAU Female SMA and ground lug
on sensor end;
Male BNC coaxial and
ground mini plug on
DAU end
- Length Fixed, 10 m (32.8 ft) standard;
3 m (9.8 ft), 5 m (16.4 ft) opt.
VibroSystM reserves the right to change specifications to improve products without notification.
ZOOM® and AGMS® are registered trademarks of VibroSystM Inc.
◊
Patented measuring technology
Processing Unit
Multi-channel Data Acquisition and
Processing Instrumentation
Application
• On-line condition and alarm monitoring of
dynamic and status parameters on hydrogenerators.
Features
• Performs synchronized measurements of connected
parameters from standstill to runaway speed in
Description automatic and manual modes (Signature, Pole,
The ZOOM Processing Unit (ZMPU) enables simultaneous
® Sampling, Trending, and Alarm measurements);
monitoring of multiple parameters for hydrogenerators. • Accepts: - one air gap input,
It performs various types of measurements in automatic and - up to 8 dynamic inputs
manual modes, processes data, checks alarm conditions and (air gap, vibration, displacement, etc.),
transmits data to ZOOM Controller. The ZMPU is compati- - up to 32 machine status inputs
ble with previous AGMS and ZOOM acquisition unit models. (MW, MVAR, temp., rpm, level, etc.),
It accepts up to 9 dynamic inputs (one air gap + a mix of air gap, - one external trigger input;
displacement, vibration, etc.) and up to 32 machine status • Continuous alarm monitoring of all inputs with
inputs (MW, MVAR, temperature, rpm, etc.). Interconnection user-defined dual-alarm thresholds:
of more ZMPU extends monitoring range and capabilities. - trigger Alarm measurements (user-defined number
The ZMPU wall-mounted enclosure is installed up to 100 m of turns pre- and post- alarm occurence),
(328 ft) outside the generator. - warn of alarm conditions over a computer network
Various peripherals enhance the ZMPU functionality: and via optional annunciation relays;
ZOOM Extension Unit, STATE Extension Unit, ZOOM-ALARM • Isolated RS-485 communication link;
Extension Unit, SELECT-100 Conditional Alarm Controller, • Fully compatible with previous AGMS and
and EXTRIG External Trigger of Alarm. ZOOM acquisition unit models.
Status RS
-4
-2
RS
Connection
• ZOOM Extension Removable screw terminals
• STATE Extension Terminal block
• LIN Module Removable screw terminals
• ZOOM-ALARM Extension Terminal block
• AGMS-ALARM Terminal block
• Synchronization Terminal block
• Power Fuse holder terminal block
Physical Characteristics
Assembly panel
• Weight 6.4 kg (14 lb)
• Height 53.3 cm (21 in.)
• Width 43.2 cm (17 in.)
• Depth 24.1 cm (9.5 in.)
NEMA4 Wall-mounted enclosure
• Weight 32.2 kg (71 lb)
• Height 61.0 cm (24 in.)
• Width 51.0 cm (20 in.)
• Depth 30.5 cm (12 in.)
VibroSystM reserves the right to change specifications to improve products without notification.
ZOOM® and AGMS® are registered trademarks of VibroSystM Inc.
ZOOM-ALARM, PCU-100, LIN-100 and STATE-100 are trademarks of VibroSystM Inc.
Web: www.vibrosystm.com
Head Office – 2727 Jacques-Cartier E. Blvd
Longueuil (Quebec) Canada J4N 1L7
Phone: (450) 646-2157
1-800-663-8379 (U.S. toll free)
Fax: (450) 646-2164
E-mail: sales@vibrosystm.com
ZOOM ®
Extension Unit
Dynamic Input Signal Conditioning
for ZOOM Processing Unit
Application
• Direct interface between a wide variety of high speed
inputs and ZOOM system;
• Conditions various analog signal types in standardized
4-20 mA signal for ZOOM Processing Unit(s).
Description Features
The ZOOM Extension Unit interfaces directly with a wide
® • Accepts up to 16 inputs from a wide range of
variety of analog signal sources (i.e. sensors, probes, analog signal types with mix and match capability
transducers, measuring devices, etc.) from up to 16 high (see AGM-P Module datasheet)
speed parameters. It provides standardized 4-20 mA
• Provides 4-20 mA signal per input to one or two
output signals to the ZOOM Processing Unit.
ZOOM Processing Units
Its flexibility permits ready connection with any existing or new • Convenient connection to user’s equipment through
signal sources. It allows the user to create customized ranges screw terminals
as well as to easily upgrade or modify machine configuration.
• Input-to-Input and Input-to-Output isolation of ±1500 V
It consists of one or two sets of up to 8 inputs connected
• FM approved
through AGM-P Signal Conditioning Modules mounted on
a backplane. Each backplane is linked to seperate ZOOM • Can accomodate PVR, NVR, LIN-100 and
Processing Units. The unit is housed in a wall-mounted MFC-100 modules on a DIN rail.
metallic enclosure located not far from its associated
ZOOM Processing Units. A DIN rail can accomodate a
limited set of PVR and NVR Voltage Regulator Modules,
LIN-100 Linearization Module, or MFC-100 Magnetic Flux
Conditioner Module.
Diagram
First set of
High Speed (Dynamic)
Parameters up to 8 signals
4-20 mA ZOOM
Processing
Two sets of up to 8 Unit #1
analog inputs each
from direct front-end
transducers or from ZOOM
instrumentation Extension
(mA, mV, V, Unit
process current,
thermocouple, RTD,
Hz, LVDT) ZOOM
Second set of Processing
up to 8 signals Unit #2
4-20 mA
ZOOM Extension Unit
General Specifications
Input Physical Characteristics
• Signal Types Any sources compatible Assembly panel
with AGM-P module: • Weight max. 6.4 kg (14 lb)
AC and DC currents, • Height 53.3 cm (21 in.)
RTD and thermocouple, • Width 43.2 cm (17 in.)
frequency, strain gage, • Depth 24.1 cm (9.5 in.)
LVDT, solid state NEMA4 Wall-mounted enclosure
(see Table on next column • Weight 32.2 kg (71 lb)
or AGM-P datasheet) • Height 61.0 cm (24 in.)
• Frequency Response Upon AGM-P Module used • Width 51.0 cm (20 in.)
(see AGM-P datasheet) • Depth 30.5 cm (12 in.)
• Accuracy 2%
Output
• Signal Type Analog, 4-20 mA, except
0-10 V for Thermocouple
Power Supply
• Quantity 2 identical power supplies AGM-P Series Input Modules
• Input Voltage 85–265 VAC, 110–330 VDC
Analog Signal Conditioning of
• Input Frequency 47–63 Hz High Speed Parameter Inputs
• Power Output 30 W max. each
• Fuse Two 2 A each, slow-blow Input and Signal Type Module
• Surge Test ANSI/IEEE C37.90.1 DC Input / ± 10 mV to ± 100 mV AGM-P1
surge withstanding capability DC Input / ± 1 V, ± 5 V AGM-P2
DC Input / ± 10 V AGM-P3
DC Input / 4 to 20 mA, 0 to 20 mA AGM-P4
Environmental AC Input / 20 mVRMS to 1 VRMS AGM-P14
AC Input / 1 to 50 VRMS AGM-P15
• Temperature Range
AC Input / 50 to 550 VRMS AGM-P16
- Operation 0° to 50°C (32° to 120°F) RTD / 100Ω Platinum /Types: 2, 3, 4 wire,
- Storage -40° to 80°C (-40° to 175°F) α = 0.00385 (linearized output) AGM-P7
• Humidity 95% noncondensing max. RTD / 100Ω Platinum /Type: 4 wire, high accuracy,
nonisolated, α = 0.00385 (linearized output) AGM-P8
RTD / 10Ω Copper /Types: 2, 3 wire AGM-P9
Connection
RTD / 120Ω Nickel /Types: 2, 3 wire AGM-P10
• Input Screw Terminals on THERMOCOUPLE / Types: J, K, T, E, R, S, B
(linearized output) AGM-P7
AGM-P backplanes
TRANSDUCER / Solid State, nonisolated AGM-P13
• Output Screw Terminals on FREQUENCY / 25 Hz to 1100 Hz AGM-P17
AGM-P backplanes FREQUENCY / 520 Hz to 25 kHz AGM-P18
• Power Terminal block STRAIN GAGE / ± 30 mV, ± 100 mV, nonisolated AGM-P11
LVDT / Types: 4, 5, 6 wire, nonisolated AGM-P12
VIBRATION / ±4 VAC; 0-2.7 Hz, 0-20 Hz, 0-160 Hz AGM-P20
VibroSystM reserves the right to change specifications to improve products without notification.
ACCELERATION / 20-360 Hz AGM-P21
ZOOM® is a registered trademark of VibroSystM Inc. PROXIMITY / 4-20 mA, -2 -18 V AGM-P24
VELOCITY / AGM-P25
Published: 95.07.14 Revised: 00.06.14
For complte details, see AGM-P Series Module datasheet
Web: www.vibrosystm.com
Head Office – 2727 Jacques-Cartier E. Blvd
Longueuil (Quebec) Canada J4N 1L7
Phone: (450) 646-2157
1-800-663-8379 (U.S. toll free)
Fax: (450) 646-2164
E-mail: sales@vibrosystm.com
ZOOM-Alarm
Extension Unit
Annunciation Relays for
Dynamic Parameter Inputs
Applications
• Interfaces with annunciation devices to warn of
alarm conditions (NOT FOR MACHINE TRIP)
• Triggers remote alarm signal in the control room
and/or unit panel
Description Features
The ZOOM-ALARM Extension Unit (AEU) purpose is to • 2-level annunciation system with dedicated relays for
warn operations/maintenance personnel of alarm conditions warning purpose (Alert / Danger) per air gap
on air gap and high speed parameters. Its relay outputs can (AGMS®) or high speed (ZOOM®) input
be used to ring a bell or flash a light in the alarm panel of • Accepts up to 16 pairs of module (Alert / Danger)
the control room.
• SPDT dry contacts
Each AGMS or ZOOM Processing Unit monitors all inputs
• Connects to one or two AGMS or ZOOM
for alarms against user-set thresholds (Alert/Danger) even
Processing Units
when the Controller is off line. When a threshold is breached
for three consecutive rotations, the system sends a trig- • Continuous alarm monitoring performed by
gering signal to the appropriate relay module in the AEU. AGMS or ZOOM Processing Unit even when
the system controller or software is turned off
The AEU consist of one or two sets of up to 16 relays (8 pairs
of Alert/Danger) mounted on a backplane. Each backplane • Modular configuration permits simple customization
is associated to separate AGMS or ZOOM Processing and upgrade
Units. The wall-mounted metallic enclosure is located • Input isolation up to 2500 VRMS
nearby or up to 100 m (300 ft) from its associated
Processing Units. Each relay module contains conditioning
circuitry and a SPDT relay.
Diagram
Dynamic To First
Inputs: AGMS or Backplane
First Set of up to 16 Relay
Air Gap or ZOOM
Processing Contacts to Annunciation Devices
High Speed
Unit #1 (8 Pairs of ALERT and DANGER Levels)
RS-485 Links
Up to 100 m ZOOM-ALARM
(300 ft) Extension
Unit
Dynamic Second Set of up to 16 Relay
Inputs: AGMS or Contacts to Annunciation Devices
Air Gap or ZOOM (8 Pairs of ALERT and DANGER Levels)
High Speed Processing To Second
Unit #2 Backplane
ZOOM-ALARM Extension Unit Relay Module
General Specifications Relay Contact Ratings @ 25°C
Power Requirements • Driver Module SDO-5
• Input voltage 85 – 265 VAC or • Contact Form SPDT Dry Contact
110 – 330 VDC • Max. switching power 2000 VA
• Input frequency 47 – 63 Hz • Max. switching voltage 380 V
• Input-to-ground isolation 2.0 kVAC • Max. switching current 8 A (10 A UL)
• Power consumption 30 Watts
Environmental
• Operating temperature 0° – 40°C (32° – 105°F)
• Storage temperature -30° – 80°C (-20° – 175°F)
Electrical Connections
• Type Terminal block
Physical Characteristics
Assembly panel
• Height 686 mm (27 in.)
• Width 533 mm (21 in.)
• Depth 107 mm (4.2 in.)
Wall-mounted Enclosure EEMAC / NEMA 4
• Height 762 mm (30 in.)
• Width 610 mm (24 in.)
• Depth 203 mm (8 in.)
VibroSystM reserves the right to change specifications to improve products without notification.
ZOOM is a registered trademark and ZOOM-ALARM is a trademark of VibroSystM Inc.
Web: www.vibrosystm.com
Head Office – 2727 Jacques-Cartier E. Blvd
Longueuil (Quebec) Canada J4N 1L7
Phone: (450) 646-2157
1-800-663-8379 (U.S. toll free)
Fax: (450) 646-2164
E-mail: sales@vibrosystm.com
STATE-100
Extension Unit
Signal Conditioning of
Machine Status Parameters for
AGMS and ZOOM Systems
Applications
• Direct interface with a wide variety of
low speed (slow evolving, quasi-static) inputs and
AGMS® or ZOOM® Systems
• Machine status information for correlating with air gap
Description and other dynamic parameters, for trending, and
The STATE-100 Extension Unit purpose is to interface for triggering alarm measurements.
with slow evolving machine parameters for which there is
only a need for status information rather than dynamic Features
behavior measurement. When taking measurements, the
AGMS or ZOOM Processing Unit records one average • Accepts up to 32 inputs
value of each input per machine rotation. User-defined • Accepts one EXTRIG input from Master Trip Relay or
alarm thresholds per input permits to trigger Alarm mea- SCADA for external triggering or Alarm measurements
surements.
• Choice of signal conditioning modules to accept
The extension is housed in a wall-mounted metallic a wide variety of analog (SA series) and
enclosure located up to 100 m (300 ft) away from its digital (SD series) input signals
associated AGMS or ZOOM Processing Unit. It accepts
up to 32 inputs, one of which can be an EXTRIG input • Alarm measurement triggering capability
from the machine master trip relay for external trigger of • Modular configuration provides great flexibility to
Alarm measurement. tailor the system for different installations
A wide range of input modules is available to condition • Input isolation:
various analog (SA series modules) and digital signals - Analog: up to 1500 VAC
(SD series modules). - Digital: up to 4000 VRMS
Diagram
Up to 32 analog inputs
from direct front-end RS-485 Links
transducers or unit panel AGMS or
STATE ZOOM
(ex: MW, MVAR, KV, Extension Up to 100 m
Amps, RPM, Level, Processing
Unit (300 ft) Unit
Temperature, Pressure,
Flow, EXTRIG, etc.)
STATE-100 Extension Unit SA and SD Series Input Modules
General Specifications Analog & Digital Signal Conditioning
of Low Speed Parameter Inputs
Power Requirements
SA Series Modules
• Input voltage 85 – 265 VAC or 110 – 330 VDC Input and Signal Type Module
• Input frequency 47 – 63 Hz
VOLTAGE
• Input-to-ground isolation 2000 VAC
0 – 25 mV SAV-1
• Power consumption 30 Watts 0 – 50 mV SAV-2
0 – 100 mV SAV-3
Environmental 0–1V SAV-4
0–5V SAV-5
• Operating temperature 0° – 40°C (32° – 105°F) Bipolar, ± 5 V SAV-6
• Storage temperature -30° – 80°C (-20° – 175°F) 0 – 10 V SAV-7
Bipolar, ± 10 V SAV-8
28 – 140 VAC SAV-9
Electrical Connections 56 – 280 VAC SAV-10
• Type Terminal blocks CURRENT
4 – 20 mADC SAC-11
0 – 5 AAC SAC-12
Physical Characteristics FREQUENCY
Bipolar, 300 Hz – 10 kHz SAF-13
Assembly panel 0 – 2,5 kHz SAF-14
• Height 686 mm (27 in.) 0 – 5 kHz SAF-15
• Width 533 mm (21 in.) 0 – 10 kHz SAF-16
• Depth 107 mm (4.2 in.) TEMPERATURE
• Wall-mounted enclosure EEMAC / NEMA 4 / RTD °C °F
100Ω Platinum -50° – 350°C -58° – 662° SAT-29
• Height 762 mm (30 in.) 100Ω Platinum 0° – 100°C 32° – 212° SAT-30
• Width 610 mm (24 in.) / THERMOCOUPLE — Not compatible
• Depth 203 mm (8 in.)
Input electrical isolation: 1500 VAC
Analog resolution: 12-bit
SD Series Modules
DIGITAL
90 – 140 VAC SDI-1
180 – 280 VAC SDI-2
3 – 32 VDC fast, > 500 Hz SDI-3
Dry contact sense,
built-in isolated voltage source SDI-4
10 – 32 VDC, 15 – 32 VAC Non-polarized SDI-5
VibroSystM reserves the right to change specifications to improve products without notification.
AGMS and ZOOM are registered trademarks, STATE-100 is a trademarks of VibroSystM Inc.
Web: www.vibrosystm.com
Head Office – 2727 Jacques-Cartier E. Blvd
Longueuil (Quebec) Canada J4N 1L7
Phone: (450) 646-2157
1-800-663-8379 (U.S. toll free)
Fax: (450) 646-2164
E-mail: sales@vibrosystm.com
LIN-231
Linearization Module for
VM 3.1 Capacitive Air Gap Sensor
Applications
• Conditions VM 3.1 Capacitive◊ Air Gap Sensor signal
and interfaces with AGMS® and ZOOM® systems,
PCU-100 Programmable Monitor, or
third-party instrumentation.
Features
• Choice of two linearized analog outputs available:
DESCRIPTION 0 to 10 V and 4 to 20 mA of raw air gap output
The LIN-231 Linearization Module conditions the signal from • Connects to ZOOM Processing Unit, PCU-100
VM 3.1 Capacitive Air Gap Sensor and provides a standard Programmable Monitor or third-party instrumentation
output compatible with common industry instrumentation.
• Designed to meet various industry standards
It linearizes the probe signal and offers a choice of both
0 to 10 V and 4 to 20 mA outputs of raw air gap, with • +24 VDC power is supplied by ZOOM Processing Unit
sensitivity of 0.555 V/mm (14 mV/mil) or 0.888 mA/mm or by an optional power supply when connected to a
(23 µA/mil), respectively. PCU-100 or third-party instrumentation
A wall-mounted enclosure houses two LIN-231 modules. • Two modules are housed in a wall-mounted enclosure
The required +24 VDC power input is provided by the • Die cast aluminum casing; splash proof
ZOOM Processing Unit. An optional power supply inside
the enclosure is needed when connecting to a PCU-100
Programmable Monitor or to instrumentation from other
manufacturers.
94 mm
BNC Probe LIN-200 Power
3.7 in.
LIN-200
SERIES
Power
Pcom
Vout 30.5 cm
Connector SERIES
Pcom
Vout
Model
Vcom
ILoop +
12 in.
Model
Vcom 69 mm Sensor Input
Product No.
Serial No.
I Loop -
Connection
• Sensor Connector Female BNC coaxial with
ground lug
• Input/Output Connector Detachable screw terminal
VibroSystM reserves the right to change specifications to improve products without notification.
AGMS® and ZOOM® are registerd trademarks of VibroSystM Inc.
◊ Patented measuring technology
Web: www.vibrosystm.com
Head Office – 2727 Jacques-Cartier E. Blvd
Longueuil (Quebec) Canada J4N 1L7
Phone: (450) 646-2157
1-800-663-8379 (U.S. toll free)
Fax: (450) 646-2164
E-mail: sales@vibrosystm.com
LIN-232
Linearization Module for
VM 3.2 Capacitive Air Gap Sensor
Applications
• Conditions VM 3.2 Capacitive◊ Air Gap Sensor signal
and interfaces with AGMS® and ZOOM® systems,
PCU-100 Programmable Monitor, or
third-party instrumentation.
Features
• Choice of two linearized analog outputs available:
DESCRIPTION 0 to 10 V and 4 to 20 mA of raw air gap output
The LIN-232 Linearization Module conditions the signal from • Connects to ZOOM Processing Unit, PCU-100
VM 3.2 Capacitive Air Gap Sensor and provides a standard Programmable Monitor or third-party instrumentation
output compatible with common industry instrumentation.
• +24 VDC power is supplied by ZOOM Processing Unit
It linearizes the probe signal and offers a choice of both
or by an optional power supply when connected to a
0 to 10 V and 4 to 20 mA outputs of raw air gap, with
PCU-100 or third-party instrumentation
sensitivity of 1.11 V/mm (28.2 mV/mil) or 1.78 mA/mm
(45.2 µA/mil), respectively. • Two modules are housed in a wall-mounted enclosure
A wall-mounted enclosure houses two LIN-232 modules. • Die cast aluminum casing; splash proof
The required +24 VDC power input is provided by the
ZOOM Processing Unit. An optional power supply inside
the enclosure is needed when connecting to a PCU-100
Programmable Monitor or to instrumentation from other
manufacturers.
94 mm
BNC Probe LIN-200 Power
3.7 in.
LIN-200
SERIES
Power
Pcom
Vout 30.5 cm
Connector SERIES
Pcom
Vout
Model
Vcom
ILoop +
12 in.
Model
Vcom 69 mm Sensor Input
Product No.
Serial No.
I Loop -
Connection
• Sensor Connector Female BNC coaxial with
ground lug
• Input/Output Connector Detachable screw terminal
VibroSystM reserves the right to change specifications to improve products without notification.
AGMS® and ZOOM® are registerd trademarks of VibroSystM Inc.
◊ Patented measuring technology
Web: www.vibrosystm.com
Head Office – 2727 Jacques-Cartier E. Blvd
Longueuil (Quebec) Canada J4N 1L7
Phone: (450) 646-2157
1-800-663-8379 (U.S. toll free)
Fax: (450) 646-2164
E-mail: sales@vibrosystm.com
LIN-250
Linearization Module for
VM 5.0 Capacitive Air Gap Sensor
Applications
• Conditions VM 5.0 Capacitive◊ Air Gap Sensor signal
and interfaces with AGMS® and ZOOM® systems,
PCU-100 Programmable Monitor, or
third-party instrumentation.
Features
• Choice of two linearized analog outputs available:
DESCRIPTION 0 to 10 V and 4 to 20 mA of raw air gap output
The LIN-250 Linearization Module conditions the signal from • Connects to ZOOM Processing Unit, PCU-100
VM 5.0 Capacitive Air Gap Sensor and provides a standard Programmable Monitor or third-party instrumentation
output compatible with common industry instrumentation.
• Designed to meet various industry standards
It linearizes the probe signal and offers a choice of both
0 to 10 V and 4 to 20 mA outputs of raw air gap, with • +24 VDC power is supplied by ZOOM Processing Unit
sensitivity of 0.222 V/mm (5.6 mV/mil) or 0.355 mA/mm or by an optional power supply when connected to a
(9 µA/mil), respectively. PCU-100 or third-party instrumentation
A wall-mounted enclosure houses two LIN-250 modules. • Two modules are housed in a wall-mounted enclosure
The required +24 VDC power input is provided by the • Die cast aluminum casing; splash proof
ZOOM Processing Unit. An optional power supply inside
the enclosure is needed when connecting to a PCU-100
Programmable Monitor or to instrumentation from other
manufacturers.
94 mm
BNC Probe LIN-200 Power
3.7 in.
LIN-200
SERIES
Power
Pcom
Vout 30.5 cm
Connector SERIES
Pcom
Vout
Model
Vcom
ILoop +
12 in.
Model
Vcom 69 mm Sensor Input
Product No.
Serial No.
I Loop -
Connection
• Sensor Connector Female BNC coaxial with
ground lug
• Input/Output Connector Detachable screw terminal
VibroSystM reserves the right to change specifications to improve products without notification.
AGMS® and ZOOM® are registerd trademarks of VibroSystM Inc.
◊ Patented measuring technology
Web: www.vibrosystm.com
Head Office – 2727 Jacques-Cartier E. Blvd
Longueuil (Quebec) Canada J4N 1L7
Phone: (450) 646-2157
1-800-663-8379 (U.S. toll free)
Fax: (450) 646-2164
E-mail: sales@vibrosystm.com
Synchronization
Probe
1/rev. Reference
Applications
• Provide a pulse per revolution for unit rotational
position reference
Features
• Proximity switch
• Easy to install on machine shaft usually below generator;
One per machine
Description • Fine adjustment capability
The Synchronization Probe provides a pulse to the • Can be used with AGMS and ZOOM ® ®
Dimensions
16 mm
(0.625")
Miniconnector
Male Terminals
81 mm 22 mm
(3.200") (0.875")
76 mm
36 mm (3.000")
(1.420")
108 mm
Miniconnector (4.250")
Female socket
Target on Shaft
Size: 20 x 10 x 3.2 mm Probe Adjustment Screws
(0.790 x 0.395 x 0.126") 63.5 mm
(2.500")
For installation details, see on back side
Synchronization Probe
General Specifications Installation
Target glued on Shaft
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
Input Characteristics Shaft
• Measuring Range 2 mm ± 0.5 2 mm ±0.5
(80 mils ± 20) 41 mm (80 mils ±20)
(1.625") From
probe tip from target face
From probe tip
hole center to target
Electrical to shaft face face
• Supply 5 to 30 V X
Axis Z
• Ripple 10% Axis Probe
• Consumption 10 mA max. X Adjustments
• Load Resistance 150 Ω min.. Axis X: 19 mm (0.750")
Z Y: 0 mm (0.000")
Axis Z: 31 mm (1.210")
Environmental
• Operation Temperature -25° to 75°C
(-13° to 167°F)
Dimensions
• Length 81 mm (3.2 in.)
• Width 108 mm (4.25 in.)
• Height 36 mm (1.42 in.)
• Weight 0.255 kg (0.6 lbs)
VibroSystM reserves the right to change specifications to improve products without notification.
ZOOM® and AGMS® are registered trademarks of VibroSystM Inc.
Applications
• Interface between system communication format and
PC compatible format
Features
• Built-in traffic controller
• RS-485 link isolated up to 2500 VRMS
• RS-232-C half duplex communication protocol
Description
The RS-232-C/RS-485 Interface is a bidirectional traffic • Wide range of power supply inputs
controller converting data from an RS-485 communication - Voltage 85-265 VAC
format to an RS-232-C format, and vice versa. The baud - Frequency 47-440 Hz
rates is 9600 bps. Isolation of the RS-485 line provides • Highly immune to electrically noisy environments
adequate protection from electrical surges which occur in • Can be used with AGMS , ZOOM , and SBV (MUL)
® ®
Diagram
RS-232-C/RS-485
Communication System
Interface RS-232-C Controller
3 m (10 ft)
TX
POWER
RX
INTERFACE RS232C/RS485
Environmental Operating
Physical
• Height 30.5 cm (12 in.)
VibroSystM reserves the right to change specifications to improve products without notification.
• Width 30.5 cm (12 in.)
ZOOM® and AGMS® are registered trademarks of VibroSystM Inc.
• Length 15.2 cm (6 in.)
Published: 90.06.01 Revised: 98.09.16 • Weight 12.3 kg (27 lb)
Applications
• Interface various high speed input signal types
from the field with the ZOOM System
®
Features
• Complete signal conditioning function per module;
one per input
• Wide variety of sensor inputs: Thermocouples,
RTDs, LVDTs, Strain Gages, Frequency, etc.
• Mix and match input capability
Description
The AGM-P Input Module is a single input signal condi- • Transfer function:
tioner that plugs into a socket on the AGM-P backplane of - Input specified sensor measurement range
the ZOOM Extension Unit and accepts its signal from the - Output 0-10 VDC for A/D conversion to ZOOM DAU
input screw terminals. The choice of a specific AGM-P 4-20 mA auxiliary output, nonisolated with
Input Module depends on the type of input signal and on respect to voltage output
whether an isolated or nonisolated interface is required. • High accuracy: ±0.1%
Input modules are available to accept millivolt, volt, • Low drift: ±1 µV/°C
process current, thermocouple, RTD, strain gage, frequency,
LVDT, and solid state temperature transducer inputs. • Reliable transformer isolation on some modules:
- ±1500 V CMV
All modules provide input signal protection, amplification, - 160 dB CMR
and filtering; accuracy of ±0.1%; low drift of 1µV/°C. They - Meets IEEE-STD 472: Transient Protection (SWC)
also feature two high level analog outputs that are com-
• Thermocouple modules interface directly with
patible with most process instrumentation. The voltage
type J, K, T, E, R, S and B:
output of each module is used for internal A/D conversion
- Cold junction compensation on each input
while the current output is available from the output screw
- Open input detection
terminals for other uses. The isolated input modules provide
±1500 V of isolation (CMV).
Diagram
Slid AGM-P
to Potentiometers Backplane
Complementary
TY
AGM-P 4-20 mA Output
P/ PE
R
S/
N
IN
P
V UT 0-10 V
O
I O UT
UT Output to
A/D Card
of the
ZOOM
Acquisition
Unit
Pin
Connectors ZOOM Extension Panel
Underneath
AGM-P Input Modules
Models Available
Type Description Input Specifications
1
AGM-P1 DC Input Module - 0 to 100 mV, ±50 mV, ±100 mV
Notes
1
Factory set: to be ordered within these defined limits
2
No 4-20 mA complementary output available
3
Factory set for one of three vibration frequency ranges: 0.01–2.7 Hz, 0.01–20 Hz, 0.01–160 Hz
4
See AGM-P21 datasheet for technical specifications
AGM-P Input Modules
General & Typical Specifications
Typical @ +25°C (77°F) and +24 VDC power / For AGM-21, see respective datasheet
Size 80 x 19.7 x 86 mm *
(3.150 x 0.775 x 3.395 in.)
Environmental
Temperature Range, Rated Performance -25° to +85°C *
(-13 to 185°F)
Storage Temperature Range -55° to +85°C *
(-67 to 185°F)
Relative Humidity Conforms to MIL Spec 202 0 to 95% @ 60°C (140°F)
non-condensing *
RFI Susceptibility ±0.5% span error *
5 W @ 400 MHz @ 1 m (3 ft)
1
Model AGM-P6 does not have a current output.
2
Accuracy specifications includes the combined effects of
repeatability, hysteresis and linearity. Does not include sen-
sor or signal source error. AGM-P14, P15 and P16 have a
±0.5% accuracy. AGM-P12 has ±0.1% accuracy when cali-
brated. AGM-P6 accuracy vary with temperature range.
3
RTD Models AGM-P7, P8, P9, P10 and LVDT Model AGM-P12
have a linearization conformity error of ±0.05%. AGM-P1, P2,
P3, P17, P18 and P20 have a ±0.02% span nonlinearized.
4
Models AGM-P8, P11, P12, and P13 each have the common
mode voltage determined by the internal excitation circuitry.
5
Includes excitation circuitry for models AGM-P7, P8, P9,
P10, P11, P12 and P13.
6
Models AGM-P1, P14 and P16 respectively have an input
resistance of 200 MΩ, 100 MΩ and 1 MΩ; models AGM-P2,
P3 and P15 have an input resistance of 250 MΩ; model
AGM-P20 has an input resistance of 10 MΩ.
7
Model AGM-P1 has a 150 Hz bandwidth; models AGM-P2
and P3 have a 200 Hz bandwidth; model AGM-P12 has a
100 Hz bandwidth; model AGM-P20 offers three factory-set
bandwiths to be specified at the order: 0.01–2.7 Hz, 0.01–20 Hz,
and 0.01–160 Hz; model AGM-P21 offers two factory-set
bandwiths to be specified at the order: 20 to 360 Hz or 0.9 to
300 Hz.
VibroSystM reserves the right to change specifications to improve products without notification.
ZOOM is a registered trademark of VibroSystM Inc.
®
Applications
• Universal operating software for ZOOM , AGMS and
® ®
SBV systems;
TM
VSM Link
ZOOM ZOOM ZOOM ZOOM ALARM
APP CONFIG APP ANLST MAP
G3 G2 G1 (opt.)
ZOOM ZOOM
Data ZOOM ANLST APP ANLST
Base CONFIG MGR (opt.)
(opt.) (opt.)
ZOOM EVENT EVENT ANLST
ZOOM MIG TEXT TEXT MGR
BASE (opt.) (opt.) (opt.) (opt.)
(Field Hardware)
Controller Workstations Workstations
(Dedicated PC computer) (PC computer) (PC computer)
Measurement Types Graphic Displays
AUTOMATIC – At user-defined intervals for long-term RECTANGULAR – Single or multiple curve graphs (up to 15);
trending of parameter evolution; Applies to all machines. With various graph tools.
• Trending Computed average value for each parameter; • Signature Values of any active parameter synchro-
Minimum interval: 15 minutes. nized with passing poles over one machine rotation.
• Signature Data on all parameters corresponding with • Pole Machine behaviour over multiple rotations;
the minimum air gap reading for each rotor pole over During tests or transitory operating conditions
one rotation; Minimum interval: 1 hour. (i.e.: run-up, run-down, field excitation, overspeed, etc.).
• Pole Similar to signature but over multiple turns; • Sampling Raw sample readings; For waveform verifi-
Minimum interval: 24 hours. cation and analysis, in static or dynamic condition.
• Sampling Raw data at full sampling rate; Minimum • Trending Parameter evolution or performance over an
interval: 24 hours. unlimited period of time; For condition-based mainte-
nance, and comparison of machine operation patterns.
TEST – Requested from ZOOM Application for verification • Alarm Machine behaviour leading to and following an
purpose (commissioning, transitory conditions, prior to works) alarm occurance; For analysis and diagnostics of incident.
on a specific machine; Performed from stanstill to overspeed.
POLAR – Drawn from signature measurements; With
• Signature As described above. various graph tools to emphasize critical locations.
• Pole As described above; User-defined number of turns, • Generator Air Gap Rotor shape inside stator shape;
typically between 2 and 100. For rotor-stator structural analysis.
• Sampling As described above; User-specified duration. • Rotor Shape Rotor profile as seen from any sensor;
For static air gap readings or rotor roundness tests.
ALARMS – Triggered by 2-level thresholds/input for analysis.
• Blade Tip Clearance (fixed-propeller and Kaplan
• Alarm Machine data prior and after alarm occurrence; turbines) Clearance of each blade inside throat ring shape.
User-defined number of recorded turns.
SPECTRUM – Shows the harmonic components of a signal;
• Message Sent to all active ZOOM Application and Requires a minimum of 256 data registers; With various
Alarm Map modules. graph tools.
STATUS – Status at time of each measurement. • Low Frequency FFT Based on Pole measurements
• STATE Record of machine operation. • High Frequency FFT Based on Sampling measurements
• EVENT Log of auxiliary equipment On/Off operation ORBIT – Displays the rotating center or geometric center
(status, numberod starts/shutoffs, total time On/Off). displacement of rotating components (generator, shaft,
NOTE: All measurements are limited by the storage bearing, turbine).
capacity of the acquisition unit. BAR – Shows EVENT statistics (ON/OFF operation of
auxiliary equipment) with total duration of each, number
of transitions; For statistics and maintenance purposes.
Communication Protocol
• Special protocol to ensure communication integrity
between system Controller and generating units’ hardware
(acquisition units and connected devices).
• NetBIOS compatibility for networking between the
Controller and multiple computer stations.
VibrosystM reserves the right to change specifications to improve products without notification.
® ZOOM & AGMS are registered trademarks, ™ SBV, STATE, EVENT & MFM are trademarks of
VibroSystM Inc. All other trandemarks and registered trademarks belong to their respective owners.