REPUBLIC OF THE PHILIPPINES

OFFICE OF THE BUILDING OFFICIAL


PROVINCE OF SURIGAO DEL SUR
CITY OF TANDAG
RECCOMENDING APPROVAL:

HEAD DATE

RECCOMENDING APPROVAL AS TO:

PROPERTY LINE
LAND USE & ZONING

HEAD DATE
RECCOMENDING APPROVAL AS TO:

LINE & GRADE


A A' B A' A HEAD DATE
2000 10000 2000 RECCOMENDING APPROVAL AS TO:

P E R S P E C T I V E
ARCHITECTURAL

2000
HEAD DATE
RECCOMENDING APPROVAL AS TO:

3
STRUCTURAL

HEAD DATE

SLOPE SLOPE RECCOMENDING APPROVAL AS TO:

2
7500
SANITARY
1
HEAD DATE
RECCOMENDING APPROVAL AS TO:

SLOPE SLOPE
1'

ELECTRICAL
2000

HEAD DATE
RECCOMENDING APPROVAL AS TO:

2 LOCATION MAP 3 SITE DEVELOPMENT PLAN


A 1 Scale NTS
A 1 Scale 1:100
BUREAU OF FIRE

CIVIL ENGINEER: PRC NO. SEAL: PROJECT TITLE REPUBLIC ACT 9266 APPROVED/OWNER: SHEET NO.
Drawing and specification duly
VALID UNTIL:
PROPOSED 1 STOREY DUPLEX stamped and sealed as instrument of services
are property and documents of the architect A
PTR NO. whether the object for which they are made are
DATE ISSUED: RESIDENTIAL BUILDING executed or not. It shall be lawful for any 1
person without written consent of the architect of MERLYN T. QUIZADA
PLACE ISSUED: LOCATION: BLOCK 1, LOT 1, PHASE _____, PANUBIGAN, BRGY. TELAJE,
said documents to duplicate or to make copies
for use in repetition of and other projects or
TIN: TANDAG CITY buildings whether executed partly or in whole. DATE APPROVED: DATE RELEASED:
A A' B 1' 1 2 3

650
TOP OF FIREWALL

750 500
ROOF APEX
A A' B A' A

200
TOP OF BEAM LINE
5000 5000
2500 2500 2500 2500
1500 1500

3000

3000
B W3 W1 W1 W2 W3
A1
D1
W4 W4

FIN. FLOOR LINE


1200

200
200
3

D3 D3
D4 T & B W1 W1 T&B D4 NAT. GROUND LINE

3250
W3 KITCHEN BEDROOM BEDROOM KITCHEN W3

2 2
DINING DINING 2 FRONT ELEVATION (TYPICAL)
3 RIGHT SIDE ELEVATION
5500

AREA D2 D2 AREA
A
A1 A 2 Scale 1:100 A 2 Scale 1:100
2
7500

LIVING D2 D2 LIVING
W2 AREA AREA W2

3250
BEDROOM BEDROOM
D1 1 1 D1
1

1000

W3 W3
W1 W1
2000

PORCH PORCH
A A' B 3 2 1 1'
1'

500
TOP OF FIREWALL

2500 2500 2500 2500 ROOF APEX

750
750
TOP OF BEAM LINE

1 FLOOR PLAN

3000
3000

W4 W1 W1 W3 W2

A 2 Scale 1:100
D3

FIN. FLOOR LINE

200
200

NAT. GROUND LINE

4 REAR ELEVATION (TYPICAL)


5 LEFT SIDE ELEVATION
A 2 Scale 1:100 A 2 Scale 1:100

CIVIL ENGINEER: PRC NO.0092146 SEAL: PROJECT TITLE REPUBLIC ACT 9266 APPROVED/OWNER: SHEET NO.
Drawing and specification duly
VALID UNTIL:
PROPOSED 1 STOREY DUPLEX stamped and sealed as instrument of services
are property and documents of the architect A
PTR NO. whether the object for which they are made are
DATE ISSUED: RESIDENTIAL BUILDING executed or not. It shall be lawful for any 2
person without written consent of the architect of MERLYN T. QUIZADA
PLACE ISSUED: LOCATION: BLOCK 1, LOT 1, PHASE _____, PANUBIGAN, BRGY. TELAJE,
said documents to duplicate or to make copies
for use in repetition of and other projects or
TIN: TANDAG CITY buildings whether executed partly or in whole. DATE APPROVED: DATE RELEASED:
A A' B A' A

TOP OF FIREWALL

750 500
ROOF APEX
TRUSSES TRUSSES 1.80 m 1.20 m 0.60 m 1.20 m 0.60 m
TOP OF BEAM LINE

0.40 m
SEE RLB DET. SEE RLB DET.

0.60 m
1.20 m
3000

1.70 m
1.50 m
W1 W1
KITCHEN KITCHEN

0.90 m
BEDROOM BEDROOM
2 2 FIN. FLOOR LINE
FIN. FLOOR LVL.
200

W1- THREE PANEL W2- TWO PANEL W3- SINGLE PANEL W4- TWO PANEL W5- OVERHEAD
NAT. GROUND LINE JALOUSIE GLASS JALOUSIE GLASS JALOUSIE GLASS JALOUSIE GLASS JALOUSIE GLASS
WINDOW WINDOW WINDOW WINDOW WINDOW
W/ ALUMINUM FRAME & W/ ALUMINUM W/ ALUMINUM W/ ALUMINUM W/ ALUMINUM
TUBULAR IN EVERY FRAME & TUBULAR FRAME & TUBULAR FRAME & FRAME
PANEL PARTITION IN EVERY PANEL IN EVERY PANEL TUBULAR IN
PARTITION PARTITION EVERY PANEL 2 SETS
4 SETS PARTITION
2 SETS 4 SETS

1 ELEVATION THRU "A"


2 SETS

A 3 Scale 1:100 3 SCHEDULE OF WINDOWS


A 3 Scale 1:100

3 2 1
650

TOP OF FIREWALL
0.90 m 0.80 m 0.70 m 0.60 m
ROOF APEX
200

TOP OF BEAM LINE


3000

2.10 m

2.10 m

2.10 m

2.10 m
BEDROOM BEDROOM
2 1
FIN. FLOOR LINE
200

NAT. GROUND LINE

D1- PANEL TYPE D2- HOLLOW CORE D1- PANEL TYPE D4- PVC DOOR
2 ELEVATION THRU "B"
DOOR FLUSH TYPE DOOR DOOR TYPE

2 SETS 4 SETS 2 SETS 2 SETS


A 3 Scale 1:100

4 SCHEDULE OF DOORS
A 3 Scale 1:100

CIVIL ENGINEER: PRC NO. SEAL: PROJECT TITLE REPUBLIC ACT 9266 APPROVED/OWNER: SHEET NO.
Drawing and specification duly
VALID UNTIL:
PROPOSED 1 STOREY DUPLEX stamped and sealed as instrument of services
are property and documents of the architect A
PTR NO. whether the object for which they are made are
DATE ISSUED: RESIDENTIAL BUILDING executed or not. It shall be lawful for any 3
person without written consent of the architect of MERLYN T. QUIZADA
PLACE ISSUED: LOCATION: BLOCK 1, LOT 1, PHASE _____, PANUBIGAN, BRGY. TELAJE,
said documents to duplicate or to make copies
for use in repetition of and other projects or
TIN: TANDAG CITY buildings whether executed partly or in whole. DATE APPROVED: DATE RELEASED:
B USE 12mm MAIN 3-12mm DIA. CUT OF BARS
A A' B A' A
REINFORCING BARS 100
5000 5000
2500 2500 2500 2500

300
SLAB-ON-FILL W/ 10mm dia. 1500 1500
TEMP. BARS @0.60m. O.C. USE 10mmØ TIES SPACED:
5 @ 0.05m; 5 @ 0.10m; 5 @
0.15m REST @ 0.20m O.C.
WF WF

L
1200
3

WF WF
F1/C3 F1/C1 F1/C1 F1/C1 F1/C3
WF WF 3 TYPICAL ROOF LINTEL BEAM DETAILS
WF

WF

3250
S 1 Scale NTS
5500

WF
WF
F1/C1 F1/C1 SECTION
WF WF
2
7500

F1/C1 USE 12mm MAIN


REINFORCING BARS USE 10mm RSB SPACED @
WF

WF
0.60m O.C. BOTHWAY
USE 10mm TIES

3250
SPACED:
F1/C3 F1/C3 F1/C3 F1/C3 5 @ 0.05m; 5 @
WF
1

0.10m; 5 @ 0.15m
1000

F1/C1 REST @ 0.20m O.C.


2000

WF WF
F1/C3 F1/C3 NATURAL GROUND LINE
1'

NATURAL GROUND LINE


F1/C2 F1/C2 F1/C2 F1/C2

0.10 m0.40 m
D
2500 2500 2500 2500

T
1 FOUNDATION PLAN PLAN
0.30 m
S 1 Scale 1:100 COLUMN FOOTING DETAILS
2 (TYPICAL) 4 TYPICAL WALL FOOTING DETAILS

S 1 Scale NTS S 1 Scale NTS

SCHEDULE OF RC COLUMNS
NOTE:
MARK C1 C2 C3 TYPE A = 1@ 50, 8 @ 100, REST @ 150mm to Center Line
SIZE 100mm X 400mm 200mm X 200mm 250mm X 150mm X 100mm TYPE B = 1@ 50, 9 @ 100, 5 @ 150, REST @ 200mm to Center Line
TYPE C = 1@ 50, 11 @ 100, 6 @ 150, REST @ 200mm to Center Line
VERT. BARS 3-12mm 4-12mm 3-12mm

TIES/SPIRAL 9mm SPACED: 5 @ 0.05m; 3 @ 0.10m; REST @ 0.20m


300 200 SCHEDULE OF FOOTING
100
250

LONG DIRECTION SHORT DIRECTION


100

CROSS SECTION B L D T
200

DESCRIPTION REMARKS
(mm) (mm) (mm) (mm)
AsBott. AsTop AsBott. AsTop
150
F-1 1000 1000 1000 200 5-12mm 5-12mm ISOLATED

CIVIL ENGINEER: PRC NO. SEAL: PROJECT TITLE REPUBLIC ACT 9266 APPROVED/OWNER: SHEET NO.
Drawing and specification duly
VALID UNTIL:
PROPOSED 1 STOREY DUPLEX stamped and sealed as instrument of services
are property and documents of the architect S
PTR NO. whether the object for which they are made are
DATE ISSUED: RESIDENTIAL BUILDING executed or not. It shall be lawful for any 1
person without written consent of the architect of MERLYN T. QUIZADA
PLACE ISSUED: LOCATION: BLOCK 1, LOT 1, PHASE _____, PANUBIGAN, BRGY. TELAJE,
said documents to duplicate or to make copies
for use in repetition of and other projects or
TIN: TANDAG CITY buildings whether executed partly or in whole. DATE APPROVED: DATE RELEASED:
A A' B A' A A A' B A' A
75 x 50 x 1.2 x 6 BOX TYPE 0.4mm THICK
100 x 50 x 2.0 x 6 C-PURLINS S.P @ GUTTER LONG SPAN BIB
RAFTER 0.60m O.C TYPE ROOFING
5600 5600 5600 5600
600 5000 5000 600
600

600
FASCIA BOARD FASCIA BOARD
3

3
6300

6300
7900

7900
SLOPE SLOPE
2

2
1

1
800

800
SLOPE SLOPE
1'

1'
1 ROOF FRAMING PLAN 2 ROOF PLAN
100 x 50 x 2.0 x 6
S 2 Scale 1:100 RAFTER S 2 Scale 1:100

75 x 50 x 1.2 x 6
C-PURLINS S.P @
0.60m O.C
VAR

500
200

3 RAFTER DETAILS
S 2 Scale NTS

CIVIL ENGINEER: PRC NO. SEAL: PROJECT TITLE REPUBLIC ACT 9266 APPROVED/OWNER: SHEET NO.
Drawing and specification duly
VALID UNTIL:
PROPOSED 1 STOREY DUPLEX stamped and sealed as instrument of services
are property and documents of the architect S
PTR NO. whether the object for which they are made are
DATE ISSUED: RESIDENTIAL BUILDING executed or not. It shall be lawful for any 2
person without written consent of the architect of MERLYN T. QUIZADA
PLACE ISSUED: LOCATION: BLOCK 1, LOT 1, PHASE _____, PANUBIGAN, BRGY. TELAJE,
said documents to duplicate or to make copies
for use in repetition of and other projects or
TIN: TANDAG CITY buildings whether executed partly or in whole. DATE APPROVED: DATE RELEASED:
FIN. FLOOR LINE CLEAN OUT WALL FINISH
CLEAN OUT
0.40 m CONCRETE SLAB MORTAR ROUTING PLUG

MASONRY WALL
0.40 m 0.10 m GRAVEL
BENT
4" THK. CHB
0.10 m 0.20 m 0.10 m W/ 10MM Ø
6"Ø PVC INLET REBARS
6"Ø PVC OUTLET
BRANCH
6"Ø PVC OUTLET
6"Ø PVC INLET
4

0.40 m

0.60 m
WCO & FCO SECTION DETAIL
0.40 m

P 1 Scale NTS
2.50 m

0.10 m 1.40 m 0.90 m 0.10 m


100 MM THK. FLOOR FINISH
0.30 m
R.C. SLAB W/ DRAIN
10MM Ø REBARS
PLAN SECTION

CONC. MANHOLE COVER W/ 16mm

5 CATCH BASIN DETAIL


INLET
LIFTING HANDLE

P 1 Scale NTS
CAST IRON PIPES
C.O

1200
OR PVC PIPE AS APPROVED
C.O

4 FLOOR DRAIN DETAIL


A A' B
P 1 Scale NTS

CB CB Ø 150 TAPPED TO MAIN

OUTLET
STORM DRAINAGE PLAN

FAU SH
VTR FD
3

LAV
WC

ST
T&B MH 0.60 m

FAU
KS

0.15 m
GV
VTR

(MIN. VAR.)
KITCHEN INLET

0.30 m
AIR SPACE
INLET
WATER LEVEL
Ø 100 SP TAPPED TO MAIN WATER LEVEL
SEWER LINE SH
2

FAU
LAV

1.85 m
KS CB
ST
WC FD

CB
1

CE DIGESTION CHAMBER LEACHING WELL


OUR Ø1
RS 50 T
ATE STO APPED
IC W
UBL RM
DRA TO MAIN
TO PUBLIC WATER SOURCE

P
TO INA
GE

2" SLOPE 2" SLOPE

0.20 m
2 ISOMETRIC DRAWING
1'

(TYPICAL) SECTION

P 1 Scale 1:100

1 3 ST PLAN, SECTION & DETAIL


PLUMBING LAYOUT (TYPICAL)
P 1 Scale 1:100 P 1 Scale NTS

CIVIL ENGINEER: PRC NO. SEAL: PROJECT TITLE REPUBLIC ACT 9266 APPROVED/OWNER: SHEET NO.
Drawing and specification duly
VALID UNTIL:
PROPOSED 1 STOREY DUPLEX stamped and sealed as instrument of services
are property and documents of the architect P
PTR NO. whether the object for which they are made are
DATE ISSUED: RESIDENTIAL BUILDING executed or not. It shall be lawful for any 1
person without written consent of the architect of MERLYN T. QUIZADA
PLACE ISSUED: LOCATION: BLOCK 1, LOT 1, PHASE _____, PANUBIGAN, BRGY. TELAJE,
said documents to duplicate or to make copies
for use in repetition of and other projects or
TIN: TANDAG CITY buildings whether executed partly or in whole. DATE APPROVED: DATE RELEASED:
Republic of the Philippines
SCHEDULE OF LOADS (TYPICAL) Province of Surigao del Sur
Circuit Quantity CITY OF TANDAG
Discription of Load Others Volt-amp Voltage Current Rating of Protection Size of Conductor
No. LO CO
LEGEND: Approved:
1 Lighting 7 175 230 0.76 15AT/ 2P THW # 2.0 mm. sq.
2 Convenience Outlet 6 1,080 230 4.69 20AT /2P THW # 3.5 mm. sq. LIGHTING OUTLET
3 Spare 1 300 230 1.3 20AT /2P THW # 3.5 mm. sq.
40AT /2P MAIN THW # 8.0 mm. sq. MAIN DUPLEX CO. ________________________________________
TOTAL 7 6 1 1,555 230 6.76
PROTECTION ENTRANCE BUILDING OFFICIAL
PANEL BOARD

230V, 10 60Hz S1 SINGLE GANG SWITCH GENERAL NOTES & SPECIFICATION:


TECHNICAL COMPUTATION (TYPICAL) 2-WIRE, GROUNDED
S3 TRIPLE GANG SWITCH ALL ELECTRICAL INSTALLATIONS INDICATED HEREIN
I=6.76AF (125%DF) SHALL BE DONE IN ACCORDANCE WITH THE LATEST
= 8.45amps. SERVICE POINT EDITION OF THE PHILIPPINE ELECTRICAL CODE PART 1,
M KILO WATT HOUR METER
THE REQUIREMENT OF THE LOCAL BUILDING OFFICIALS
WEATHER CAP AND THE UTILITY SERVING THE AREA.
Therefore: Use 2 no. 8.0 mm sq. THW wire for Service Entrance CIRCUIT BREAKER
M KILOWATT-HOUR METER
Therefore: Use 40AT, 2P, CB for Main Protection SERVICE ENTRANCE THE CIRCUIT / CONDUIT RUN SHOWN IN THE PLAN ARE
ONLY SCHEMATIC AND INTENDEED TO SERVE AS
SWITCH RUN INSTALLATION GUIDE ONLY. ACTUAL RUN SHALL BE
DETERMINED IN THE FIELD.
PANEL BOARD CIRCUIT RUN
UNLESS OTHERWISE INDICATED, THE MINIMUM SIZE OF
CONDUCTOR SHALL BE 2.0 MM2 TW.

A A' B
4 SINGLE LINE DIAGRAM ALL ELECTRICAL MATERIALS SHALL BE THE APPROVED
TYPE FOR THE SPECIFIC LOCATION.
E 1 Scale NTS
ALL ELECTRICAL INSTALLATIONS SHALL BE DONE UNDER
A DIRECT AND IMMEDIATE SUPERVISION OF A DULY
LICENSED ELECTRICAL ENGINEER.
3

SERVICE
EQUIPMENT

-MAIN 2-
40 AT 20 AT
-1 3-
20 AT
2

15 AT
CIRCUIT
GROUNDING
BUS

2 MAIN BOARD JUMPER


EQUIPMENT GROUNDING
1

BUS
EQUIPMENT GROUNDING
JUMPER
GROUNDING ELECTRODE
CONDUCTOR
GROUND ROD (WATER PIPE)
1'

PANEL BOARD SCHEMATIC


1 2 DIAGRAM
ELECTRICAL PLAN (TYPICAL) 3 LOCATION MAP
E 1 Scale 1:100 E 1 Scale NTS
E 1 Scale NTS

ELECTRICAL ENGINEER: PRC NO. SEAL: PROJECT TITLE REPUBLIC ACT 9266 APPROVED/OWNER: SHEET NO.
Drawing and specification duly
VALID UNTIL:
PROPOSED 1 STOREY DUPLEX stamped and sealed as instrument of services
are property and documents of the architect E
PTR NO. whether the object for which they are made are
DATE ISSUED: RESIDENTIAL BUILDING executed or not. It shall be lawful for any 1
person without written consent of the architect of MERLYN T. QUIZADA
PLACE ISSUED: LOCATION: BLOCK 1, LOT 1, PHASE _____, PANUBIGAN, BRGY. TELAJE,
said documents to duplicate or to make copies
for use in repetition of and other projects or
TIN: TANDAG CITY buildings whether executed partly or in whole. DATE APPROVED: DATE RELEASED:

You might also like