Gear pins........................................AS REQUIRED RIGHT SEAT CHALLENGE LEFT SEAT DO VERIFY Steering bypass..................….......AS REQUIRED Circuit Breakers...............................………..............CHECK
Nose Strut Extension……………..…....10 IN MAX Parking Break......................................……….................SET
Wheel Chocks...……………….…...AS REQUIRED ENG/APU Fire /Overheat....................…….…..............TEST Tires & Brakes……………………………….CHECK Extinguisher (1&2 ).............................…….…..............TEST Engine Cowls……………………..………..CLOSED BOTTLE DISCHARGED Lights...........……....................OFF Engine inlet & Exhaust…………..…………CLEAR Radios .................................................…….....................SET Flight Controls & Flaps………….………....CLEAR Engine Start Levers ..........................…….….........CUT OFF All Access & Cargo Doors.………..……..CLOSED Thrust Levers....................................……......................IDLE Ramp Area …………………………...………CLEAR Reverse Thrust Levers...……..…….. DOWN,FWD THRUST Cabin Doors……………………………...…COLSED Flap Handle.........................………..........WITH INDICATION NOTE: If APU electrical power is on line, ENG OIL Qty (60% Min ).........………........................CHECK Proceed to PRE_START CHECK. Hydraulic Qty (76% Min A & B).………...................CHECK Engine Start Levers………….……………CUTOFF Nose Wheel Steering Switch.........…….................NORMAL Flap Handle…………………….WITH INDICATION Fuel Cross feed Selector.........……............AS REQUIRED Gear Handle...…………………………..…….DOWN CTR Tank Fuel Pumps..............……….........AS REQUIRED Fuel Pumps……………………….………..ALL OFF NOTE: Do Not Use If CTR tank has below 1000 Lbs ELEC Hyd. Pump Switches...….………….......OFF 1 & 2 Tank FWD Fuel Pumps……….............AS REQUIRED Pack Switches…….…………………..…….…..OFF Galley Power Switch...............……….............................OFF APU Bleed Switch.....……...……….…….….…OFF Standby Power Switch ......………..............CAPPED/AUTO 1 & 2 IDG Ground Power……………………...AS REQUIRED Disconnects ......………........CAPPED/SAFETIED PRE-POWER ON Check..…..…..... COMPLETED Emergency Exist Lights....………................AS REQUIRED Battery Switch & Volts...……….……ON / 23 VDC Engine Start Switches ..........………..............................OFF Extinguisher 1 & 2……………….……………TEST Reverser Lights 1 & 2..............………............................OFF APU Master Switch...…START,RELEASE TO ON EEC Switch 1 & 2 .....................……................................ON When ( APU GEN BUS OFF ) Light Illuminates: Window Heat Switches.............……….........AS REQUIRED # 1 Tank AFT Pump..……………….……………ON ENG Ati-Ice Switches ....................………....AS REQUIRED APU FIRE ELEC Hyd Pump Switches 1 & 2 (B First)..……….........ON Parking Brake……………………….…………..SET Pack Switches.......................................……..................OFF Isolation Valve APU Fire Handle……………...…PULL & ROTATE Switch.........................…………………………..............AUTO APU BOTTLE DISCHARGER Light...………….ON 1 & 2 Engine Bleed Switches..........………....................OFF Ground Control.…..…...REQUEST ASSISTANCE Duct pressure................................……….........AVAILABLE IF FIRE PERSISTS: Position lights...............................……...................STEADY Engine Start Levers.………….…………..CUT OFF Anti-Collision Lights......................................................ON Battery Switch…………………..……………….OFF Master Caution ........................................................RESET A & B HYd System Press......................................3000 PSI ARM SLIDE IF REQUIRED AND EVACUATE. Hydraulic Brake Pressure.....................................3000 PSI
RIGHT SEAT CHALLENGE LEFT SEAT DO/VERIFY RIGHT SEAT CHALLENGE LEFT SEAT DO VERIFY Start area…………………………………………….CLEAR Battery Switch & Volts………………………..ON / 23 VDC
Engine Start Switch……………………..……….GRD Standby Power Switch………………………………….BAT
“Start Valve Open” message…………………….ON ELEC Hyd Pumps………………………………….BOTH OFF N2 Rotation………………………………………….N2 Ignition Switch……………………….………………R (Right) Oil Press Rise……………………..…………Oil Press N1 rotation…………………………..………………..N1 NOTE: Only N1 & N2 will initially display Start Lever (At Max N2 Above 22%)………….IDLE Until about 15% N2
Monitor Only: Engine Start Switch…………………………..GRD & HOLD
Initial FF (Approx.)…………………………..600PPH Engine Start………………………PROCEED AS NORMAL EGT (725 Deg Max)…………………WITHIN 10 SEC Starter Cutout (At 56%N2)……………SWITCH OFF When Engine Stabilizes: Oil Press…………………….…………….13 PSI MIN Engine Indications………………….…STABILIZED Engine Generator…………………………………………..ON Standby Power Switch………………………………..AUTO PRE-TAXI ELEC Hyd Pumps (1&2) …………………………………ON Ground Crew & Equipment……………….CLEAR Ignition Switch…………………………………………..BOTH Engine Generators…………………..AS REQUIRED CROSSBLEED START Packs…………………………………..AS REQUIRED Packs………………………………………………………..OFF Taxi Clearance………………………..AS REQUIRED Isolation Valve……….... ……………………………..AUTO Parking Brake……………………………..RELEASED APU Bleed Switch………………………………………….OFF POST-TAXI Engine Bleed Switch (Supply ENG)……………………..ON Trust Levers……………………………………..IDLE Area……………………………………………………..CLEAR Parking Brake…………………………………..SET Thrust Lever (Supply ENG)………ADVANCE FOR 30 PSI APU or GND Power……………………….AVAILABLE Receiving Engine………………………….NORMAL START Start Levers…………………………………..CUTOFF Thrust Lever (At Starter Cutout)………………………IDLE Fuel Pumps…………………………………….. …OFF Engine Bleeds/Packs………………………..AS REQUIRED NOTE: If APU is running, leave #1 AFT pump ON ABNORMAL STARTS ELEC Hyd Pumps………………………………….OFF Engine Start lever…………………..………………..CUTOFF Packs…………………………………AS REQUIRED Engine Motoring (Continue)…………………………60 SEC APU Bleed……………………………AS REQUIRED Engine Start Switch……………………………………….OFF Anti-collision Light (Below 20% N2)……….. OFF Parking Brake (If Chocked)……………RELEASED ENGINE FIRE Gear Pins (If Installed)…..………………REMOVED Parking Brake………………………………………………SET POWER SHUTDOWN (APU OR EXT) Thrust Levers………………………………………………IDLE Start Lever (Affected ENG)………………………….CUTOFF Pack Switches……………………..……………..OFF Engine Fire Handle…………………………PULL & ROTATE APU Bleed…………………………..……………..OFF BOTTLE DISCHARGE Light……………………………….ON Window Heat Switches……………..……..ALL OFF Ground Control……………………REQUEST ASSISTANCE Probe Heat Switches………………..……..ALL OFF If Fire Continues……………DISCHARGE OTHER BOTTLE ELEC Hyd Pumps…………………..…….BOTH OFF Emergency lights Switch…………….………….OFF IF FIRE PERSISTS: L&R IRS Selectors……………………………….OFF Start Lever (Opposite ENG)…………………………CUTOFF Galley Power………………………………………OFF Battery Switch………………………………………………OFF Fuel Pumps………………………..…………ALL OFF GRD Power…………………………….…………..OFF APU GEN Switches……………..………..BOTH OFF ARM SLIDE IF REQUIRED AND EVACUATE APU Start Switches………………………………OFF Battery Switch (30 sec after Shutdown)………OFF