Professional Documents
Culture Documents
CEIL Motive Power Chargers With DERIVATIVE Function-brochure-July 2013
CEIL Motive Power Chargers With DERIVATIVE Function-brochure-July 2013
CEIL Motive Power Chargers With DERIVATIVE Function-brochure-July 2013
SERIES 3
Features
Charging Graph as per DIN 41774 Simple plug in and use
Microprocessor controlled charge Robust 50Hz power transformer
Double safety timer: Gassing point & Water & Energy saving
Maximum charge time Extended battery life
DERIVATIVE final cycle Equalise and Preservation charge
Programmable for specific application feature built in
Charger Selection Table
Battery AH
Model
8 - 9 Hr 12 - 13 Hr
10 55 80
15 83 120
20 110 160 AC Mains Input available for:
25 135 200 220V +/- 5%, 1-Phase, 50Hz
30 165 240
400V +/- 5%, 3-Phase, 50Hz
40 220 320
50 275 400 (230V +/- 5%, 3-Phase:
60 330 480 available on special request)
70 385 560
80 440 640
90 495 720 Supplied with AC input cable and 13A
100 550 800 plug (UK) if applicable.
120 660 960 DC Connector Socket can be fitted on
140 770 1120 request at extra cost.
160 880 1280 Higher Amps Chargers available on
180 990 1440 request.
200 1100 1600
DERIVATIVE function in the final charging phase ensures precise Charge Termination by
automatically sensing when DC output voltage is no longer rising. Battery charging voltage is
monitored at specific intervals and fed back to the controller, where the data is compared
continuously to ascertain when the battery is fully charged.
Benefits
Eliminates over or under-charging
Does not over-charge battery even if some cells are weak or defective
Water & Energy saving
Extended battery life
Continuous development may lead to specifications change without prior notice. // CEIL /SERIE 3/ AG / July 13/ 2-2 //