RTN 905 s V100R019C10 Product Description 02
RTN 905 s V100R019C10 Product Description 02
RTN 905 s V100R019C10 Product Description 02
V100R019C10
Product Description
Issue 02
Date 2020-04-30
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: https://www.huawei.com
Email: support@huawei.com
Related Versions
The following table lists the product versions related to this document.
NCE V100R019C00
Intended Audience
This document is intended for network planning engineers.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
Symbol Description
General Conventions
The general conventions that may be found in this document are defined as
follows.
Convention Description
Change History
Changes between document issues are cumulative. Therefore, the latest document
issue contains all the changes made in earlier issues.
Topic Description
Contents
3 Product Structure.................................................................................................................. 11
3.1 IDU 905 s................................................................................................................................................................................. 11
3.1.1 Functional Units and Logical Boards.......................................................................................................................... 11
3.1.2 Service Single Processing Flow..................................................................................................................................... 12
3.1.3 Front Panel.......................................................................................................................................................................... 14
3.1.4 Air Duct................................................................................................................................................................................. 20
3.1.5 Ethernet Optical/Electrical Module Types.................................................................................................................20
3.2 ODU........................................................................................................................................................................................... 21
5 Technical Specifications....................................................................................................... 30
5.1 RF Specifications................................................................................................................................................................... 30
5.1.1 Microwave Working Modes and Air Interface Capacity.......................................................................................30
5.1.2 Receiver Sensitivity............................................................................................................................................................34
5.1.3 Frequency Band..................................................................................................................................................................44
5.1.4 Transceiver Performance................................................................................................................................................. 45
5.2 Predicted Equipment Reliability....................................................................................................................................... 50
5.2.1 Predicted Component Reliability.................................................................................................................................. 51
5.2.2 Predicted Link Reliability................................................................................................................................................. 51
5.3 Ethernet Interface Specifications..................................................................................................................................... 52
5.4 Equipment Performance..................................................................................................................................................... 56
6 Accessories.............................................................................................................................. 60
7 Cables....................................................................................................................................... 73
7.1 Power Cable............................................................................................................................................................................ 73
7.2 IDU PGND Cable................................................................................................................................................................... 74
7.3 IF Cable..................................................................................................................................................................................... 75
7.4 IF Jumper................................................................................................................................................................................. 77
7.5 Fiber Jumper........................................................................................................................................................................... 78
7.6 Network Cable....................................................................................................................................................................... 80
1 Introduction
The OptiX RTN 905 s is a split microwave device developed by Huawei. It is mainly
used for enterprise private lines.
1.1 Components
The OptiX RTN 905 s adopts a split structure, consisting of the IDU 905 s, ODU,
and antenna. An ODU is connected to the IDU 905 s through an IF cable.
1.2 Typical Application Scenarios
1.1 Components
The OptiX RTN 905 s adopts a split structure, consisting of the IDU 905 s, ODU,
and antenna. An ODU is connected to the IDU 905 s through an IF cable.
IDU 905 s
The IDU 905 s is the indoor unit of the OptiX RTN 905 s. It provides functions
including service access, multiplexing, IF processing, and system communication
and control.
Chassis height 1U
Number of microwave 1
directions
ODU
The ODU is the outdoor unit of the OptiX RTN 905 s. It provides functions
including frequency conversion and power amplification of signals.
The OptiX RTN 905 s can use the XMC-3 ODU/XMC-3W ODU to cover all
frequency bands from 7 GHz to 38 GHz.
There are two methods for mounting the ODU and the antenna: direct mounting
and separate mounting.
● Direct mounting is generally adopted when a small- or medium-diameter
single-polarized antenna is used. In this case, one ODU is used with one
antenna, and the ODU is directly mounted at the rear of the antenna. Figure
1-3 shows direct mounting.
The OptiX RTN 905 s provides a full-band antenna solution that offers antennas with a
diameter of 0.3 m to 3.7 m and the corresponding antenna accessories.
The OptiX RTN 905 s provides a wide assortment of functions and features to
ensure the quality and efficiency of service transmission.
Clock Clock source Traces the clock source and provides the
system clock, service signal frame headers,
and overhead signal frame headers for each
unit.
The clock sources that can be traced
include:
● Microwave link clock
● Synchronous Ethernet clock, which is not
supported by small form-factor
pluggable (SFP) electrical modules
Number of IF ports 1
Pseudo random binary Supports PRBS bit error rate (BER) tests at
sequence (PRBS) test IF ports.
Manufacturer Supported
information query
Table 2-2 lists the Ethernet service functions of the IDU 905 s.
ETH OAM Ethernet service ● Supports ETH OAM functions that comply
OAM with IEEE 802.1ag.
● Supports packet loss, delay, and delay
variation detection functions that comply
with ITU-T Y.1731.
3 Product Structure
On the NMS, each functional unit on the system board of the IDU 905 s is
mapped to a logical board and is allocated a logical slot, thereby allowing object-
specific network management.
EG6 4-port RJ45+2- Slot 7 Provides six GE ports, among which four are
port SFP RJ45 GE electrical ports and the other two use
Gigabit SFP modules to work as 2.5GE/GE/FE optical
Ethernet (GE) ports or GE electrical ports. The GE electrical
interface ports are compatible with FE electrical ports.
board
Indicators
Indicators visually communicate the operating status of the equipment.
Power Port
The IDU 905 s supports one –48 V power input. Figure 3-4 shows the appearance
of the power port.
Only the NMS port is available. The N/A ports are reserved network management ports and
are unavailable.
The NMS port uses an RJ45 connector. Figure 3-5 shows the front view of an RJ45
connector.
5 Not defined
7 Not defined
8 Not defined
Service Ports
GE4
GE5 FE/GE/2.5GE service port RJ45 SFP electrical 7.6 Network Cable/7.5 Fiber
(SFP module) module, LC SFP Jumper
GE6 optical module, or
NOTE
If either port GE5 or GE6 SFP+ optical
needs a 2.5GE optical module
module, insert 2.5GE optical
modules into both ports.
GE electrical ports support the MDI, MDI-X, and auto-MDI/MDI-X modes. Table
3-9 and Table 3-10 provide the pin assignments for an RJ45 connector in different
modes.
Optical modules are required when the SFP ports on the IDU 905 s function as
optical ports.
● If a dual-fiber bidirectional SFP optical module is used, it provides a TX port
and an RX port. As shown in Figure 3-6, the port on the left is the TX port
and the port on the right is the RX port. One optical fiber needs to be
connected to each port for transmitting or receiving service signals.
● If a single-fiber bidirectional optical module is used, only one port (port on
the left) is available for receiving and transmitting signals. An optical fiber is
connected to this port to transmit and receive service signals.
Table 3-11 Types of SFP modules that the GE/FE ports support
3.2 ODU
The ODU is an integrated system that is available in several models. The
architectures and working principles of the various ODU models are similar.
Block Diagram
The O&M uplink signal is a 5.5 MHz ASK-modulated signal and is demodulated in
the CTRL control unit.
The -48 V DC power signal is sent to the PWR power unit where the secondary
power supply that uses a different voltage is generated and provided to the
modules of the ODU.
The O&M downlink signal is modulated under the ASK scheme in the CTRL unit.
The 10 MHz signal is generated through the modulation and is sent to the
multiplexer. The CTRL unit also detects the received signal power through the RSSI
detection circuit and provides the RSSI interface.
The IF signal and the O&M downlink signal are combined in the multiplexer and
then are sent to the IDU through the IF cable.
This chapter describes the network management solution and NMS software that
constitutes this solution.
Function Overview
Function Description
Function Description
4.3 NCE
The Network Cloud Engine (NCE) is a network management system of Huawei.
The NCE integrates the functions of the network management system, software-
defined networking (SDN) controller, and network analysis system. It provides not
only FCAPS functions (fault, configuration, accounting, performance, and security),
but also advanced functions such as network visualization, service automation,
and intelligent O&M.
The NCE delivers these functions by means of applications. The major functions
designed for the RTN network are listed in Table 4-2 and Table 4-3.
Function Overview
Function Description
Function Description
5 Technical Specifications
This chapter describes the technical specifications of the OptiX RTN 905 s.
5.1 RF Specifications
This section describes RF specifications and technical specifications related to
microwave.
5.2 Predicted Equipment Reliability
Equipment reliability consists of component reliability and link reliability.
5.3 Ethernet Interface Specifications
Ethernet interface specifications comply with IEEE 802.3.
5.4 Equipment Performance
This section describes equipment performance in terms of dimensions, weight,
power consumption, power supply, EMC, surge protection, safety, and
environment.
5.1 RF Specifications
This section describes RF specifications and technical specifications related to
microwave.
IS3 The IS3 mode is the only IF running mode supported by the RTN 905 s.
This mode enables air-interface interconnection between the OptiX RTN
905 s and the OptiX RTN 905 s or between the OptiX RTN 905 s and the
ISV3 board.
There are 13 modulation schemes available in IS3 mode: QPSK Strong,
QPSK, 16QAM Strong, 16QAM, 32QAM, 64QAM, 128QAM, 256QAM,
512QAM, 512QAM Light, 1024QAM, 1024QAM Light, and 2048QAM.
Among them, 2048QAM can be used only when AM is enabled.
The IS3 mode can be used when the XMC-3W ODU or XMC-3 ODU is
used.
7 QPSK Strong 8 to 10 8 to 14 8 to 18 8 to 24
7 QPSK 10 to 13 10 to 17 10 to 22 10 to 31
7 16QAM 17 to 22 17 to 29 17 to 37 18 to 51
Strong
7 16QAM 20 to 26 21 to 34 21 to 45 21 to 61
7 32QAM 25 to 32 25 to 42 26 to 55 26 to 75
7 64QAM 32 to 40 32 to 54 33 to 70 33 to 95
7 128QAM 37 to 48 38 to 63 38 to 82 39 to 112
7 256QAM 42 to 53 43 to 71 43 to 92 44 to 125
7 512QAM 45 to 57 45 to 75 46 to 98 46 to 133
14 (13.75) QPSK 21 to 26 21 to 35 21 to 45 21 to 62
14 (13.75) 512QAM 100 to 127 101 to 168 102 to 219 104 to 297
Light
14 (13.75) 1024QAM 104 to 131 105 to 174 106 to 227 107 to 307
14 (13.75) 1024QAM 109 to 138 110 to 182 111 to 238 113 to 323
Light
28 (27.5) 32QAM 110 to 139 111 to 184 112 to 240 114 to 325
28 (27.5) 64QAM 135 to 172 137 to 227 138 to 296 140 to 402
28 (27.5) 128QAM 160 to 203 162 to 268 164 to 351 166 to 475
28 (27.5) 256QAM 183 to 232 185 to 306 187 to 400 190 to 542
28 (27.5) 512QAM 196 to 249 198 to 328 200 to 429 203 to 581
28 (27.5) 512QAM 210 to 266 212 to 351 214 to 459 218 to 622
Light
28 (27.5) 1024QAM 217 to 275 220 to 364 222 to 475 225 to 644
28 (27.5) 1024QAM 228 to 289 230 to 382 233 to 499 237 to 676
Light
28 (27.5) 2048QAM 242 to 306 244 to 405 247 to 529 251 to 716
56 (55) 16QAM 148 to 188 150 to 248 151 to 325 154 to 440
Strong
56 (55) 16QAM 173 to 220 175 to 290 177 to 379 180 to 514
56 (55) 32QAM 217 to 275 219 to 363 222 to 475 225 to 643
56 (55) 64QAM 273 to 346 276 to 457 279 to 597 283 to 809
56 (55) 128QAM 323 to 409 327 to 541 330 to 706 335 to 957
56 (55) 256QAM 369 to 467 373 to 617 376 to 806 383 to 999
56 (55) 512QAM 395 to 501 400 to 661 404 to 864 410 to 1000
56 (55) 512QAM 423 to 536 427 to 708 432 to 925 439 to 1000
Light
56 (55) 1024QAM 447 to 567 452 to 748 456 to 978 464 to 1000
56 (55) 1024QAM 481 to 609 486 to 805 491 to 999 499 to 1000
Light
56 (55) 2048QAM 502 to 636 507 to 839 512 to 999 520 to 1000
The guaranteed receiver sensitivity requires a 3 dB backoff from the typical value.
Unless otherwise specified (for example, XMC-3W ODU), the receiver sensitivity
specifications in the following tables do not vary with ODU types. However, the supported
frequency bands and modulation schemes vary with ODU types.
N/A means that microwave working mode is not supported.
Frequency Range (GHz) in the following tables refers to the range of a frequency band.
For the operating frequency range that each T/R spacing supports, see RTN
ODU&Antenna&Accessory Hardware Description.
7 23
30 28 28 26 26 24 24 23 21
GHz
8 23
30 28 28 26 26 24 24 23 21
GHz
11 20
27 25 25 25 25 23 23 20 20
GHz
13 19
26 24 24 23 23 21 21 20 19
GHz
15 21 19
26 24 24 23 23 22 20 19
GHz
18 19
25 23 23 22 22 21 21 20 19
GHz
23 20.5 18
25 23 23 22 22 20.5 19 18
GHz
26
22 21 21 19 19 17 17 15 15 15
GHz
28
23 20 20 19 19 19 19 18 17 17
GHz
32
23 20 20 19 19 19 18 17 16 16
GHz
38 13
20 18 18 17 17 16 16 14 13
GHz
7 GHz 5 5 5 5 5 5 5 5 5
8 GHz 5 5 5 5 5 5 5 5 5
11 -4 -4 -4 -4 -4 -4 -4 -4 -4
GHz
13
-5 -5 -5 -5 -5 -5 -5 -5 -5
GHz
15 -5
-5 -5 -5 -5 -5 -5 -5 -5
GHz
18
-7 -7 -7 -7 -7 -7 -7 -7 -7
GHz
23 -7
-7 -7 -7 -7 -7 -7 -7 -7
GHz
26
-10 -10 -10 -10 -10 -10 -10 -10 -10
GHz
28
-6 -6 -6 -6 -6 -6 -6 -6 -6
GHz
32
-10 -10 -10 -10 -10 -10 -10 -10 3
GHz
38
-6 -6 -6 -6 -6 -6 -6 -6 0
GHz
7 GHz -20 -20 -20 -20 -20 -20 -25 -25 -30
8 GHz -20 -20 -20 -20 -20 -20 -25 -25 -30
13
-20 -20 -20 -20 -20 -20 -25 -25 -30
GHz
15 -25
-20 -20 -20 -20 -20 -20 -25 -30
GHz
18
-20 -20 -20 -20 -20 -20 -25 -25 -30
GHz
23 -25
-20 -20 -20 -20 -20 -20 -25 -30
GHz
26
-20 -20 -20 -20 -20 -20 -25 -25 -30
GHz
28
-20 -20 -20 -20 -20 -20 -25 -25 -30
GHz
32
-20 -20 -20 -20 -20 -20 -25 -25 -30
GHz
38
-25 -25 -25 -25 -25 -25 -30 -30 -35
GHz
Table 5-19 ATPC maximun range and Frequency stability of the XMC-3 ODU
Item Specification
7 GHz 30 ≤ ±5 ppm
NOTE
8 GHz 30 When the T/R spacing is 311.32
MHz or 151.614 MHz, the
11 GHz 32 frequency tolerance meets the
requirement of the ETSI.
13 GHz 34
15 GHz 34
18 GHz 35
23 GHz 35
26 GHz 32
28 GHz 33
32 GHz 33
38 GHz 30
7 GHz 29 27 27 25 25 23 23 22 20
8 GHz 29 27 27 25 25 23 23 22 20
13
25 23 23 22 22 21 20 19 18
GHz
15
25 23 23 22 22 21 21 19 19
GHz
18
24 22 22 21 21 20 20 18 17
GHz
23
24 22 22 21 21 19.5 19.5 18 18
GHz
7 GHz 5 5 5 5 5 5 5 5 5
8 GHz 5 5 5 5 5 5 5 5 5
13 -5 -5 -5 -5 -5 -5 -5 -5 -5
GHz
15 -5 -5 -5 -5 -5 -5 -5 -5 -5
GHz
18 -7 -7 -7 -7 -7 -7 -7 -7 -7
GHz
23 -7 -7 -7 -7 -7 -7 -7 -7 -7
GHz
7 GHz -20 -20 -20 -20 -20 -20 -25 -25 -30
8 GHz -20 -20 -20 -20 -20 -20 -25 -25 -30
13GH -20 -20 -20 -20 -20 -20 -25 -25 -30
z
15GH -20 -20 -20 -20 -20 -20 -25 -25 -30
z
18GH -20 -20 -20 -20 -20 -20 -25 -25 -30
z
23GH -20 -20 -20 -20 -20 -20 -25 -25 -30
z
Table 5-23 ATPC maximun range and Frequency stability of the XMC-3W ODU
Item Specification
7 GHz 29 ≤ ±5 ppm
NOTE
8 GHz When the T/R spacing is 311.32
MHz&151.614MHz, the frequency
13 GHz 33 tolerance meets the requirement of
the ETSI.
15 GHz
18 GHz 34
23 GHz
Failures in time (FITs) are an indicator of equipment reliability in the Telcordia SR-332 standard.
Both FITs and MTBF are affected by the quality level factor, electrical stress factor, and
temperature stress factor of the component.
The calculation formula between FITs and MTBF is as follows:
● FITs = 109/MTBF (hour)
● Annual failure rate (%) = [1/MTBF (year)] x 100%
Table 5-24 lists the component reliability of Integrated IP microwave with typical
configuration.
Item Specifications
IDU ODU
MTTR (hour) 1 1
Table 5-25 lists the equipment reliability of a single Integrated IP microwave hop
with 1+0 configuration.
Table 5-25 Predicted equipment reliability of a single hop with 1+0 configuration
Item Specifications
MTTR (hour) 1
Availability 99.99939%
Item Specifications
Overload (dBm) 0 -3
Item Specifications
Item Specifications
Overload (dBm) -3 -3 -3
Nominal wavelength (nm) Tx: 1490 Tx: 1310 Tx: 1490 Tx: 1310
Rx: 1310 Rx: 1490 Rx: 1310 Rx: 1490
Operating wavelength (nm) Tx: 1480 to Tx: 1260 to Tx: 1480 to Tx: 1260 to
1500 1360 1500 1360
Rx: 1260 to Rx: 1480 to Rx: 1260 to Rx: 1480 to
1360 1500 1360 1500
Overload (dBm) -3 -3 -3 -3
The OptiX RTN 905 s uses SFP modules to provide GE optical interfaces. Users can use different
types of SFP modules to provide GE optical interfaces with different classification codes and
transmission distances.
Item Specifications
Item Specifications
Transmission 0.3 2 10
distance
(km)
Item Specifications
Operating wavelength (nm) 1270 to 1380 1261 to 1360 1263 to 1360 1480 to 1580
Nominal wavelength (nm) Tx: 1550 Tx: 1310 Tx: 1550 Tx: 1310
Rx: 1310 Rx: 1550 Rx: 1310 Rx: 1550
Item Specifications
Operating wavelength (nm) Tx: 1480 to Tx: 1260 to Tx: 1480 to Tx: 1260 to
1580 1360 1580 1360
Rx: 1260 to Rx: 1480 to Rx: 1260 to Rx: 1480 to
1360 1580 1360 1580
The OptiX RTN 905 s uses SFP modules to provide FE optical interfaces. Users can use different
types of SFP modules to provide FE optical interfaces with different classification codes and
transmission distances.
Dimensions
Component Dimensions (H x W x D)
Weight
IDU 2.52 kg
Power Consumption
IDU 25.3 W
ODU ≤ 24.5 W
Power Supply
Component Specifications
Electromagnetic Compatibility
● CE certified
● Compliant with ETSI EN 301 489-1
● Compliant with ETSI EN 301 489-4
● Compliant with CISPR 32
Lightning Protection
● Compliant with IEC 61000-4-5
● Compliant with ITU-T K.20
● Compliant with ITU-T K.44
Safety
● CE certified
● Compliant with ETSI EN 60215
● Compliant with ETSI EN 60950
● Compliant with UL 60950
● Compliant with IEC 60825
● Compliant with GB 4943
Environment
The IDU operation requires controllable temperature and weather protection. The
ODU is used outdoors.
Item Specifications
IDU ODU
Item Specifications
IDU ODU
6 Accessories
This chapter describes the accessories that are optionally used for the RTN 905 s,
including the E1 panel, USB flash drive, and power distribution unit (PDU).
Front Panel
Basic function Converts the 220 V AC input power into stable –56 V DC
output power.
Input Supported
overcurr
ent
protecti
on
Overte Supported
mperatu
re
protecti
on
Power Cable
The AC input power cable is used by the AC power supply device to supply AC
power to the AC power adapter. The DC output power cable is used by the power
adapter to output DC power to the RTN 905 s.
The DC power cable terminal delivered with the power adapter cannot be directly used on
the RTN 905 s. The DC power cable terminal applicable to the RTN 905 s has the following
specifications: 4-pin and top screw/horizontal lead wire (as shown in Figure 6-2). Therefore,
the power cable must be re-assembled onsite. For details, see RTN 905 s IDU Quick
Installation Guide.
Technical Specifications
Maximum input 2A
current
Output ≥ 89%
efficiency
Regulated ≤ ±2.7%
voltage precision
Item Specifications
Protection Input ≤ 85 V AC
undervoltage
protection
threshold
Input ≤ 90 V AC
undervoltage
recovery
threshold
Output ≤ 57.5–60 V DC
overvoltage
protection
threshold
Output ≤ 3.25–4.35 A
overcurrent
protection
threshold
Altitude ≤ 5000
NOTE
● When the altitude is below 1800 m, the
ambient temperature does not change.
● When the altitude is above 1800 m, the
ambient temperature drops by 1°C for every
220 m increment in altitude.
Item Specifications
6.2 SSC6PDU
An SSC6PDU is installed on the top of a 19-inch cabinet to distribute the input
power supply to devices in the cabinet.
Ports
Functions
● Supports two -48 V/-60 V DC power inputs.
● Allows each power input to provide four power outputs.
● Supports a 20 A fuse capacity for each power output switch.
● Supports DC-C and DC-I power distribution.
Working Principle
An SSC6PDU consists of input terminals, output terminals, and circuit breakers and
it performs simple distribution operations for the input power.
Front Panel
Figure 6-7 shows a universal PDU (DPD63-8-8 PDU). Different types of short-
circuiting copper bars are used to match different types of power current supplied
by the power supply equipment in the equipment room. The DPD80-2-8 PDU is a
2-input and 8-output PDU developed based on the DPD63-8-8 PDU.
On the front panel, Area A and Area B each receives one -48 V/-60 V power input
and provides four power outputs to subracks inside the cabinet.
Internal Structure
Figure 6-8 shows the internal structure of a DPD80-2-8 PDU. The power input and
output ports are inside the PDU. Input and output power cables are connected to
these ports.
● Power output area: On either side of the DC PDU, there are four output
terminal blocks that are used to connect the power cables of subracks.
● Power input area: INPUT A and INPUT B are each connected to one -48 V DC
power cable and one power ground cable, that is, two -48 V DC power cables
and two power ground cables in total.
● Power switch area: On both sides of the DC PDU, there are respectively four
power output switches controlling the corresponding power output terminals.
The power output switches control power supply to the corresponding
subracks.
Functions
● Supports two -48 V/-60 V DC power inputs.
● Allows each power input to provide four outputs.
● Supports a 20 A fuse capacity for each power output switch.
Working Principles
The DPD80-2-8 PDU consists of input terminals, output terminals, and circuit
breakers. It simply distributes the input power.
7 Cables
This chapter describes the purpose, appearance, and pin assignments of various
cables used on the IDU 905 s.
If an OptiX RTN 905 s uses an AC power box, the load power cable delivered with the AC
power box must be used. See Power Cable.
Cable Diagram
2.5 mm2 power Power cable, 450 V/750 V, Common terminal, single
cable and H07Z-K-2.5 mm2, blue/black, cord end terminal, conductor
terminal low smoke zero halogen cross section 2.5 mm2, 12.5
cable A, insertion depth 8 mm
For the OptiX RTN 905 s, power cables with a 2.5 mm2 cross-sectional area can extend for a
maximum distance of 50 m.
Cable Diagram
Pin Assignments
None.
7.3 IF Cable
The IF cable connects the ODU and IDU. The IF cable is used to transport the IF
signal, O&M signal, and -48 V power between the ODU and the IDU.
IF cables are of three types, namely, 5D cable, RG-8U cable, and 1/2-inch cable.
A 5D cable connects the IF interface of an ODU to the IF interface of an IDU. An RG-8U cable or
1/2-inch cable connects the IF interface of an ODU to the IF jumper of an IDU.
Cable Diagram
Technical Specifications
Item Performance
Characteristic 50 50 50
impedance (ohm)
Item Performance
Attenuation ≤ 10.0 (140 MHz) ≤ 6.0 (140 MHz) ≤ 5.0 (140 MHz)
(dB/100 m) ≤ 15.0 (350 MHz) ≤ 9.0 (350 MHz) ≤ 7.8 (350 MHz)
7.4 IF Jumper
An IF jumper connects the IDU to an IF cable. The IF jumper works with the IF
cable to transmit IF signals and O&M signals in addition to supplying -48 V power
between the ODU and the IDU.
● If a 5D IF cable is used, you can connect the cable directly to an IF board instead of
using an IF jumper.
● If an RG-8U or 1/2-inch IF cable is used, an IF jumper is required to connect the RG-8U
or 1/2-inch IF cable to the IF board.
Cable Diagram
1. RF coaxial cable connector, TNC, male 2. RF coaxial cable connector, Type N, female
Pin Assignments
None.
2 mm multi-mode fiber
2 mm multi-mode fiber
2 mm multi-mode fiber
For the OptiX RTN 905 s, multi-mode fibers are required to connect to 1000BASE-SX GE optical
ports.
Fiber Connectors
The following figures show three common types of fiber connectors, namely,
LC/PC connector, SC/PC connector, and FC/PC connector.
Two types of interfaces use RJ45 connectors, which are medium dependent
interfaces (MDIs) and MDI-Xs. MDIs are used by terminal equipment, for example,
network card. The pin assignments for MDIs are provided in Table 7-5. MDI-Xs are
used by network equipment. The pin assignments for MDI-Xs are provided in
Table 7-6.
Straight-through cables are used between MDIs and MDI-Xs, and crossover cables
are used between MDIs or between MDI-Xs. The only difference between straight-
through cables and crossover cables is with regard to the pin assignment.
The NMS/COM port, NE cascading port, and Ethernet electrical service ports of
the OptiX RTN 905 s support the MDI, MDI-X, and auto-MDI/MDI-X modes.
Straight-through cables and crossover cables can be used to connect the
NMS/COM port, EXT port, and Ethernet electrical service ports to MDIs or MDI-Xs.
Cable Diagram
Pin Assignments