GENERAL NOTES

1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE


PROVISIONS OF THE PHILS. PLUMBING CODE. THE NATIONAL PLUMBING CODE AND ROOF
RULES & REGULATIONS OF THE CITY

2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS.


THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN.

3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATIONS REQUIRED SEALING
FOR PROPER EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR APPROVAL OF THE CAP
ARCHITECT/ENGINEER.

4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION. DEPTH


AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE
CONTRACTOR.

5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% AND 2% UNLESS CUSTOM MADE
BOX GUTTER
OTHERWISE SPECIFIED.
WATER
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE PROOFING
MEMBRANE
MANUFACTURER'S INSTRUCTIONS.

7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATION


THE WORKS WITH SEWER LINE EFFLUENT DISPOSAL POINT & WATER LINE SERVICE
CONNECTING POINT UNLESS OTHERWISE SPECIFIED.

8. ALL PIPE SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS UNLESS
OTHERWISE SPECIFIED.

9. ALL PIPE DIAMETER ARE INSIDE DIMENSION (NOMINAL) UNLESS OTHERWISE SPECIFIED.
SECTION

10. VERIFY ARCHITECTURAL PLANS FOR THE EXACT LOCATION OR SETTING OUT OF FLOOR
DRAINS, FLOOR CLEAN-OUTS AND OTHER PLUMBING APPURTENANCES.

11. ALL CONCEALED VALVES OR VALVES AT CEILING LEVEL SHALL BE PROVIDED WITH ACCESS
MANHOLE. SCALE
12. ALL PIPES PASSING THROUGH WALLS, SLABS AND BEAMS MUST HAVE A PIPE SLEEVE
ONE SIZE BIGGER THAN THE ACTUAL PIPE SIZE TO PREVENT PIPE BREAKAGE AND TO
MAINTAIN SLOPE OF THE PIPE. 500
300
13. RISERS AND STACKS SHALL BE PROVIDED WITH SWAY BRACES EVERY OTHER FLOOR
STARTING AT GROUND FLOOR.

HEAVY DUTY

1000
STEEL GRATING

G
DIN
UIL
YB
RE
TO
2-S
W
NE

DING
UIL
EYB
OR
-ST
IST
ING
2
PLAN
EX

500
FIN. FLOOR LINE 300

L- 75X75X6 FRAME

VARIES
HEAVY DUTY

(MIN)
STEEL GRATING
ING
ING IST
UIL
D EX AL
CA
N 100MM TRENCH DRAIN
B
EY
OR

100
T
W
2-S
ING
STORM DRAINAGE PIPE
NE IST 100MM DIAMETER
EX AL
N
CA

TAP TO 200MM DIA.


STORM DRAIN COLLECTOR PIPE

SECTION
ING
IST
EX AL
N
CA

SCALE
SCALE
GA
TE

PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.

REPUBLIC OF THE PHILIPPINES


DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GENERAL NOTES
NATIONAL CAPITAL REGION
CONSTRUCTION OF LSS MOTORPOOL BUILDING,
SITE DEVELOPMENT PLAN P
CAMP BGEN RAFAEL T CRAME, QUEZON CITY,
2ND STREET, PORT AREA MANILA PHASE II
STEEL GRATING AND TRENCH CARLA A. PALCONIT SATURNINO E. DIAMZON III HANZEL B. SAMSON JUBY B. CORDON, CEO LORETA M. MALALUAN, CESO IV 1 2
DRAIN DETAIL ENGINEER II ENGINEER III OIC, PLANNING & DESIGN DIVISION ASSISTANT REGIONAL DIRECTOR REGIONAL DIRECTOR