Professional Documents
Culture Documents
SDS JOTAFIX PU
SDS JOTAFIX PU
Relevant identified uses of the substance or mixture and uses advised against
Identified uses
Use in coatings - Industrial use
Use in coatings - Professional use
SDSJotun@jotun.com
36902;36903 2 36902
^(ValidationDate) 1
Approved
Special protective actions for : Promptly isolate the scene by removing all persons from the vicinity of the incident if
fire-fighters there is a fire. No action shall be taken involving any personal risk or without
suitable training. Move containers from fire area if this can be done without risk.
Use water spray to keep fire-exposed containers cool.
Special protective equipment : Fire-fighters should wear appropriate protective equipment and self-contained
for fire-fighters breathing apparatus (SCBA) with a full face-piece operated in positive pressure
mode.
Environmental precautions : Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air). Water polluting material. May be harmful
to the environment if released in large quantities.
Appropriate engineering : Use only with adequate ventilation. Use process enclosures, local exhaust
controls ventilation or other engineering controls to keep worker exposure to airborne
contaminants below any recommended or statutory limits. The engineering controls
also need to keep gas, vapour or dust concentrations below any lower explosive
limits. Use explosion-proof ventilation equipment.
Environmental exposure : Emissions from ventilation or work process equipment should be checked to ensure
controls they comply with the requirements of environmental protection legislation. In some
cases, fume scrubbers, filters or engineering modifications to the process
equipment will be necessary to reduce emissions to acceptable levels.
Body protection : Personal protective equipment for the body should be selected based on the task
being performed and the risks involved and should be approved by a specialist
before handling this product. When there is a risk of ignition from static electricity,
wear anti-static protective clothing. For the greatest protection from static
discharges, clothing should include anti-static overalls, boots and gloves.
Other skin protection : Appropriate footwear and any additional skin protection measures should be
selected based on the task being performed and the risks involved and should be
approved by a specialist before handling this product.
Respiratory protection : Based on the hazard and potential for exposure, select a respirator that meets the
appropriate standard or certification. Respirators must be used according to a
respiratory protection program to ensure proper fitting, training, and other important
aspects of use.
If workers are exposed to concentrations above the exposure limit, they must use a
respirator according to EN 140. Use respiratory mask with charcoal and dust filter
when spraying this product, according to EN 14387(as filter combination A2-P2). In
confined spaces, use compressed-air or fresh-air respiratory equipment. When use
of roller or brush, consider use of charcoalfilter.
Bioaccumulative potential
Product/ingredient name LogPow BCF Potential
xylene 3.12 8.1 to 25.9 low
ethylbenzene 3.6 - low
hydrocarbons, C9, aromatics - 10 to 2500 high
maleic anhydride -2.78 - low
Mobility in soil
Soil/water partition : Not available.
coefficient (KOC)
Users should always consult Jotun for specific guidance on the general suitability of this product for their needs and
specific application practices.
If there is any inconsistency between different language issues of this document, the English (United Kingdom)
version will prevail.