Shanghai Chang Ai Technology&Development Co.

,Ltd (headquarters)

No.97,Qibao Wanxin International Center,Lane 1333,Xinlong Road,Minhang District,Shanghai,P.R.China.201101

Tel:021-51692285
Product Brochure
Fax:021-33275656

Chengdu Chang Ai Electronic Technology Co., Ltd

R & D center:5/F,Huaxia Building,No.3,section 3,Jianshe North Road,Chenghua District,Chengdu

Production base:199,Huaguan Road,economic city,Longtan headquarters,Chenghua District,Chengdu

Fax:028-83277736

National unified service hotline:400 700 8817


Scan Focus on Chang Ai
For more information,please visit www.ci-ele.com
Chang Ai·Gas analysis expert
The edition of this volume is cI.1.18. The information is for reference only. It is subject to change without notice
CHANGAI Electronic Science & Technology Co., Ltd
Brand story Enterprise culture Core competitiveness

Shanghai Chang Ai Electronic Technology Co.,Ltd. The Company is committed to the research and Enterprise mission Excellent R&D and innovation
is a high-tech enterprise in Shanghai, a member of the application of various leading-edge analysis and Provide the best analysis, measuring instruments, capabilities
National Gas Standardization Technical Committee,a detection technologies,it has more than 100 varieties solutions and services for air separation,chemical, Company has an excellent team integrating profes-
gas analysis technical committee of the national in 8 series:oxygen analyzer series, dew point analyzer environmental protection and other industries,mak- sional design,production,maketing and management,
Semiconductor Equipment and Materials Standard- series,thermal conductivity analyses series,infrared ing work safer,more efficient,and making the life and plans to launch more than 5 new product series
ization Technical Committee,and a deputy director analyzer series,and laser(TDLAS) analysis Instrument healthier and environmentally friendly. each year.
unit of the Gas Analysis Technology and Instrument series, high temperature and humidity analyzer series,
Professional Committee of China Industrial Gas liquid phase analyzer series,process analysis system,
Association. etc.Products are widely used in environmental protec- Enterprise vision Strict production quality system
tion.Metallurgy,petrochemical,chemical,energy,food, Become a analyzer expert of China,respected by the Company has a complete production system for
agriculture,transportation,water conservancy,construc- society and make employees proud! precision instruments.
Since its establishment in October 2004,Chang Ai is
tion, pharmaceutical, brewing, aviation and scientific Full implementation of ISO9001:2008 international
mainly engaged in the research,development and
research and many other industries,and exported to quality management system.
production of sensors and secondary instruments
and systems engineering with the current world-lead-
more than 20 countries and regions including Germa Enterprise spirit
ny,the United States,Britain,Korea,India,Russia and so
ing level.It is a manufacturer of scientific and techno-
on
The pursuit of excellence,beyond ourselves. Comprehensive marketing
logical instruments with scientific and technological service network
personnel as the main body. In a few years,it has gone Provide a full range of quality service.
In the face of the rapid development of today’s
through the research and development stage of Enterprise purposes The perfect office and customer service terminal
electronic technology and the market economy,our
high-tech new products with high investment,high risk Reciprocity and mutual benefit,mutual promotion and provide domestic customers with a response within
company will take “The effort to revitalize the industri-
and rapid growth,and has quickly entered the high-tech, complementarity,and create common prosperity. 4 hours and on-site service and consultation within
al control industry in China and strive to create an
high-output and high-efficiency industrialization stage,- 48 hours.From technical consultation,solution design,
internationally renowned industrial control brand.”as
becoming Shanghai Electronic Information Technolo- to tailor-made solutions for customers and imple-
the goal,and put people first,work hard,and further
gy and Growth Enterprise.The company strictly manag- Enterprise values mentation,and to operator training and after-sales
strengthen the internal software and hardware construc-
es the quality assurance of design,development,pro- service.Throughout the process,the company relies
tion.Utilize the company’s accumulated experience in Integrity,harmony,win-win and sharing.
duction,installation and service in accordance with on geographical conditions and technical advantag-
the field of industrial testing and automation for many
the ISO9001 international standard quality system. es in the field of analytical applications to provide
years,continue to develop, provide value - for - money
products and services to each user,and strive to contrib- customers with high-quality products and compre-
The company has a number of invention patents,hun- ute to China’s modernization! hensive service,and provide overall solutions that
dreds of utility models and appearance patent technol- meet the needs of customers.In Germany,Japan,In-
ogies.It has undertaken a number of national and dia,Thailand,Malaysia,Korea,Russia and other countries
Shanghai science and technology projects,including and regions have agents to serve foreign markets.
the National Innovation Fund,key new product plans,
torch plans,and achievement transformation.In 2014,it
became the lead drafting unit of the National Standard
for the Determination of Trace Oxygen in Gases and
established the leader position of Chang Ai in the Technology refines quality
analysis industry
confidence creates the future
Development History Product catalogues

Environmentally friendly (CEMS) ion current high temperature humidity meter


has been successfully developed ;

2004 A member of the National Gas Standardization Technical Committee;


Shanghai Chang Ai Technology Co.,Ltd.was established;
Lon current principle high temperature and humidity analyzer was awarded
the Chengdu Science and Technology SME Technology;Innovation Fund Project; On-line trace oxygen analyzer Constant oxygen analyzer
Chang Ai was established;
The zirconia principle analyzer was successfully
Chengdu R&D Center was established; developed; CI-PC90 Trace oxygen analyzer 01 CI-PC162 Frequency conversion ion flow
The ion flow sensor has been successfully
developed; 2006 Chang Ai oxygen analyzer became a military
equipment; CI-PC91 Trace oxygen analyzer 02 oxygen analyzer 24
The first ion current high oxygen analyzer of Jiaxin office was established;
China was successfully developed to fill the The lon flow oxygen analyzer is designated by CI-PC96/961 Trace oxygen analyzer 03 CI-PC11 Frequency conversion ion flow
domestic gap. Antarctic research team;
Full access to steel,metallurgy,chemical and other
CI-PC99 Trace oxygen analyzer 04 oxygen analyzer 25
2009 fields;
CI-PC16 Frequency conversion ion flow CI-PC951/-1 Explosion-proof oxygen analyzer 26
CHANG-AI your preferred quality supplier The NOx analysis The instrument won the
Shanghai High-tech Achievement Transformation oxygen analyzer 05 CI-PC951-2 Explosion-proof oxygen analyzer 27
Gas Analyzers Specialist Project;
The lon flow principle NOx analyzer won national CI-PC125 Frequency conversion ion flow CI-PC85/-1 Explosion-proof oxygen/nitrogen
Chang Ai
key new product.
Member of China Gas Association; oxygen analyzer 06 analyzer 28
3D ion flow nitrox sensor developed successfully;

Expert in gas analyzers


A gas analysis technical committee of the national CI-PC128/-1 Frequency conversion ion flow CI-PC15/-1 Explosion-proof oxygen analyzer 29
Semiconductor Equipment and Materials Standardiza-
tion Technical Committee,and a deputy director unit oxygen analyzer 07
of the Gas Analysis Technology and Instrument
CI-PC12 Frequency conversion ion flow
About us
Professional Committee of China Industrial Gas

High content oxygen analyzer


2012
Association;
Trace oxygen analyzer won the Shanghai High-tech
oxygen analyzer 08
Shanghai Chang Ai Electronic Technology Co.,Ltd. Achievement Transformation Project;;
CI-PC121 Frequency conversion ion flow
Became the lead drafting unit of the National CI-PC81 High content oxygen analyzer 30
is a high-tech enterprise in Shanghai,a member of the Standard for the Determination of Trace Oxygen in oxygen analyzer 09
National Gas Standardization Technical Committee,a gas Gases; CI-PC82 High content oxygen analyzer 31
The Fuel cell trace oxygen sensor has been successful- CI-PC129 Trace oxygen analyzer 10
analysis technical committee of the national Semiconductor ly developed. CI-PC84 High content oxygen analyzer 32
Equipment and Materials Standardization Technical Commit- CI-PC95/-1 Explosion-proof trace oxygen
CI-PC86 High content oxygen analyzer 33
tee,and a deputy director unit of the Gas Analysis Technolo-
Participated in the revision of the national
analyzer 11
standard for the determination of trace moisture in CI-PC851/-1 Explosion-proof high-content
gy and Instrument Professional Committee of China Indus- gas analysis; CI-PC95-2 Explosion-proof trace oxygen analyzer 12
The high-temperature humidity meter based on the oxygen analyzer 34
trial Gas Association.

2015
“constant current spray method principle” GNL-STM3 Oxygen analyzer 13
was successfully developed;
GNL-2100L Portable high content oxygen
P860 Oxygen/nitrogen analyzer 14
Company has more than 100 varieties in 8 series products Innovative and patented technology-flow proportion-
analyzer 35
al control device based on solenoid valve was
which are widely used in environmental protection.Metallur- successfully developed; CI-PC832 Portable high content oxygen
gy,petrochemical,chemical,energy,food,agriculture,transpor- CO2 efficient,high-quality recycling monitoring system

tation,water conservancy,construction,pharmaceutical,brew-
was successfully developed; Portable trace oxygen analyzer analyzer 36
Launched oxygen monitoring terminal for high
ing,aviation and scientific research and many other indus- altitude diffuse environment.
GNL-B1A Portable trace oxygen analyzer 15
tries,and exported to more than 20 countries and regions
CI-PC93 Portable trace oxygen analyzer 16
including Germany,the United States,Britain,Korea,India, Russia Oxygen-enriched environment
and so on .
Shanghai Ai Po Sensing Technology
CI-PC931/932 Portable trace oxygen analyzer 17
Co.,Ltd.Was established;
New alumina and new sensors have GNL-2100 Portable oxygen/nitrogen analyzer 18 CI1300 Oxygen monitor 37
been successfully developed;
Chang Ai has obtained a number of invention patents in the Phase One Instrument(Shenzhen) Co., CI-PC832 Portable oxygen/nitrogen analyzer 19 CI-PC89 Monitoring instrument for dispersion

2018
past ten years,hundreds of utility models and appearance Ltd.Was established;
oxygen in plateau 38
The Shenzhen Ai Ci company was CI-PC13 Portable trace oxygen analyzer 20
patent technologies,and nine types of registered trademarks.
established; CI-PC894 Series-monitoring instrument for
TDLAS laser analyzer was successful-
Since its establishment in 2004,Chang Ai has adhered to the ly developed; dispersion oxygen in plateau 39
corporate spirit of pursuing excellence and surpassing
Polymer film humidity sensor was Constant oxygen analyzer CI-PC836 Oxygen content/oxygen partial
itself.With the corporate tenet of mutual benefit,mutual pressure analyzer 40
CI-PC962 Electrochemical oxygen analyzer 21
benefit,mutual benefit and co-prosperity.It is determined to
CI-PC912 Electrochemical oxygen analyzer 22 CI-PC896 Monitoring instrument for dispersion
become an expert in analyzers of China,respected by the
society and make employees proud! CI-PC933 Portable trace oxygen analyzer 23 oxygen in plateau 41

For more information,please visit www.ci-ele.com


Proven reliable technology
preferred quality supplier
Product catalogues

Oxygen transmitter Moisture meter (P2O5) High temperature hygrometer Water quality analyzer
GNL-B5/CI-PC981 Micro oxygen transmitter 42 CI-PC382 Micro-water transmitter 67 CI-PC156 Explosion-proof high temperature 61200 Portable dissolved oxygen analyzer 103
CI-PC98-1/2/3 Oxygen analyzer 43 CI-PC329 Micro-water analysis system 68 humidity meter 85 61101 On-line dissolved oxygen gas analyzer 104
CI-PC881 Oxygen/Nitrogen transmitter 44
GNL-120-1/3 Oxygen transmitter 45
Nitrogen oxygen compound analyzer Industrial process
GNL-3100 Series oxygen/nitrogen transmitter 46
Thermal conductivity analyzer CI-XT100-B Coke oven gas analysis system 105
CI-PC882 Ambient oxygen transmitter 47 CI-PC791 Nitroxide compounds analyzer 86
CI-PC50 Thermal conductivity analyzer 69 CI-XT300 On-line monitoring system for CDQ
CI-PC85-2 Explosion-proof oxygen/nitrogen CI-PC79 Nitrogen oxide compound analysis
CI-PC53 Portable thermal conductivity analyzer 70 coke oven cycle 106
analyzer 48 system 87
CI-PC55/-1 Explosion-proof thermal conductivity CI-XT800 On-line monitoring system for carbon
CI-PC851-2 Explosion-proof high-content oxygen CI-PC71 Nitrogen oxidation gas analyzer 88
analyzer 71 dioxide recovery 107
analyzer 49
CI-PC551-2 Explosion-proof thermal conductivity CI-XT6003C Brazing furnace on-line analysis
CI-PC88 High content oxygen analyzer 50
CI-PC886 High content oxygen transmitter 51 analyzer 72 Optical gas analyzer system for multi-point inspection 108
CI-PC56 Thermal conductivity analyzer 73 CI-XT6400 On-line analysis system for gas
CI-PC888/-1 Oxygen transmitter 52 CI-PC20 Infrared gas analyzer 89
CI-PC511 Thermal conductivity analyzer 74 generator 109
CI-PC21 Infrared gas analyzer 90
CI-XT62B Heat treatment furnace-controllable
Flue oxygen analyzer CI-PC23 Portable infrared gas analyzer 91
atmosphere analysis system 110
CI-PC182-1/2 Flue oxygen analyzer 53 CI-PC261 Infrared gas analyzer 92
CI-XTPC68 On-line oxygen analysis of
CI-PC191/-1 Series direct inserted oxygen On line hydrogen analyzer CI-PC25/-1 Explosion-proof infrared gas analyzer 93
explosion-proof centrifuge 111
analyzer for flue gas 54 CI-PC2200 Ultraviolet analyzer 94
CI-PC562 Micro-hydrogen analyzer 75
CI-PC192 Flue oxygen analysis system 55 CI-PC68/-1 Laser gas analyzer 95
CI-PC582 Trace hydrogen transmitter 76
CI-PC6500 In-situ laser gas analyzer 96 Mass flowmeter
CI-PC502 Selective hydrogen content analyzer 77
BT200 Ozone analyzer 97 CI-SM80 General flow mass instrument
Dew point meter CI-PC512 Selective hydrogen content analyzer 78
(insertion) 112
CI-PC30 Dew point analyzer 56 CI-PC552 Selective explosion-proof hydrogen

CI-PC31 Dew point analyzer 57 content analyzer 79 Multicomponent gas analyzer


CI-PC35/-1 Explosion-proof dew point analyzer 58
Compressor condenser
CI-PS10 Portable biogas analyzer 98
CI-PC35-2 Explosion-proof dew point analyzer 59 CI-XT683 On-line explosion-proof biogas analysis CI-R300P/B Series condenser 113
CI-PC36 Dew point analyzer 60 system 99
High temperature hygrometer
GEN-25 Portable dew point analyzer 61 CI-PU20 Multicomponent flue gas analyzer 100
CI-TM Series dew point transmitter 62 CI-TP19 Textile high temperature humidity meter 80
Filter
CI-PC251 Explosion-proof two-component
CI-QM Series dew point sensor 63 CI-PC193Food processing high temperature and analyzer 101 CI-GF2600/2800 Filter 114
CI-BM05 Micro-water and temperature humidity system 81 CI-GF2900 Activated carbon filter (corrosion
transmitter in oil 64 CI-PC196-1 High temperature and humidity resistance) 115
CI-BM146/147 dew point and pressure transfer system 82 Hydrogen sulfide analyzer AF-1000 Filter 116
for compressed air 65 CI-PC39 Constant current injectionsystem for CI-PC952/-1 Explosion-proof hydrogen sulfide AF-2000 Filter 117
GNL-STM3-DP Dew point analysis system 66 high temperature and humidity 83 analyzer 102 AF-4000 Filter 118
On-line trace oxygen analyzer On-line trace oxygen analyzer

CI-PC90 CI-PC91
Trace oxygen analyzer Trace oxygen analyzer
CI-PC90 is a trace oxygen analyzer developed and CI-PC91 is a trace oxygen analyzer that adopts fuel
produced by our company.It is an on-line analyzer based cell oxygen sensor as the detection unit,and combines
on microprocessor and adopts fuel cell oxygen sensor as microcontroller with digital processing technology.It has
the detection unit,which has good response time,repeata- complete self-diagnosis function,monitoring the working
bility and precision. status of the instrument at any time.The analyzer has the
advantages of intelligence,stability,reliability and long ser
-vice life.It is suitable for accurate measurement of oxygen
concentration in mixed gases in various industries and
environments.

Product Features Technical Specifications Product features Technical Specifications


・The oxygen concentration and various settings are Environment ・ Digital temperature compensation function:it adopts Sample gas flow rate:1.5~2L/min
displayed on 240*128 LCD screen. temperature: 0~45°C Environment Humidity:<80%RH the most advanced temperature compensation method Simple gas pressure: atmospheric conditions±10% (Gas outlet
・The unique protective gas circuit is adopted to Sample gas pressure: atmospheric conditions±10% (Gas outlet in the world,and its temperature compensation effect is should be atmospheric conditions)
should be atmospheric conditions) Analyzer Size: L×W×H=483mm×300mm×177mm
automatically cut off the gas circuit when shutdown or world leading.
Sensor: Fuel cell oxygen sensor
power failure occurs,which effectively protects the ・ Over-voltage protection function:when the internal
sensor from being exposed to the air for a long time
Analyzer size: W×H×D=275mm×190mm×300mm
pressure of the gas circuit exceeds the protection range,
Principle
Install hole size: W×H=224×180mm
and affecting the life of the sensor. the gas circuit will be cut off automatically to avoid the

氧传感器的原理结构
Analyzer weight: about 6.8kg 氧
oxygen
Gas permeable
・The solenoid valve is placed at the air inlet and air damage of the sensor due to too large or too small 薄电解质层
Thin electrolyte
气体渗透膜
layer membrane
阴极
cathode
outlet of the sensor chamber to control whether the pressure;
sample gas flows through the sensor;
Applications ・ Pressure compensation function:reduce the influence Principle and structure
of oxygen sensor 电解质
Electrolyte OH
e-
・When the oxygen concentration exceeds the range or It is suitable for on-line or intermittent detection of of pressure on the oxygen concentration in sensor test,
anode
阳极
the pressure exceeds the range, the sensor is protected high purity gases,such as nitrogen,hydrogen,helium, arg- making the measurement more accurate.
by closing the air path through the solenoid valve. on,industrial ethylene,propylene and other gases that do ・ Over range protection function: concentration protec-
・The new structure of the test chamber is adopted to not react with alkaline electrolytes and electrodes;The tion function,when the oxygen concentration exceeds Contact
接触片 strip
facilitate the field replacement of the sensor; the protective concentration, the gas path will be cut Current
电流信号 signal
instrument can be used as a test tool in various production
・Automatic adjustment within the measurement range off automatically,so as to avoid the influence of the It consists of cathode+anode+electrolyte.The contact metal
and research departments,such as synthetic ammonia
of 0-25%,and the minimum measurement range is sensor's performance and life in the environment with sheet in the figure is connected to the cathode and anode as
0-10ppm; production,vacuum cleaning and filling,various container
high oxygen concentration for a long time.; electrode leads respectively.The electrolyte overflows throu
・Automatic temperature compensation eliminates the -s,pipelines washing and replacement,advanced plastic ・ The new structure of the test chamber and the use of -gh many circular holes of the cathode on the upper surface
influence of ambient temperature. production,identification of deoxidizing catalyst,air separa digital sensors can not only be replaced on site,but also to form a thin layer of electrolyte,which is covered with a
-tion,protection gas detection in semiconductor industry, need no calibration. polytetrafluoroethylene (PTFE) membrane that can permeate
etc. gas.
The measured gas passes through the osmotic membrane
Technical Specifications and enters the thin electrolyte.The oxygen in the gas sample
Technical Specifications Order Information Sensor principle: fuel cell type undergoes the following electrochemical reactions in the
Measure range: 0~10/100/1000ppm/1%/25.00% O2 battery:
・ Pneumatic connection mode:A,Φ6 hose (standard);
Measure range: 0~10/100/1000ppm,0~25%(can automatically Accuracy: 0.01~9.99ppm O2: ±5% FS Gold cathode:O2+2H2O+4e-→4OH- Graphite anode: C+4OH-
switches the range) B,connecting by using 1/4 "Φ6 stainless steel cutting 10.0~99.9ppm O2: ±3% FS →CO2+2H2O+4e- Comprehensive Reaction of Batteries:O2+C
Accuracy: 0.01~9.99ppm O2:±5% FS ferrule;C,connecting by using 1/8 "-Φ3 stainless steel 100~1000ppm O2: ±2% FS →CO2
10.0~99.9ppm O2:±3% FS
cutting ferrule; Repeatability: 0.01~9.99ppm O2: ±2.5% FS The reaction is irreversible.The current generated by OH- ion
100~1000ppm O2:±2% FS 10.0~99.9ppm O2: ±1.5% FS current is proportional to the concentration of oxygen in the
Repeatability: 0.01~9.99ppm O2:±2.5% FS
・ Filter:GF2800,AF2000;
100~1000ppm O2: ±1% FS gas sample.In the absence of oxygen,there will be no reaction
10.0~99.9ppm O2:±1.5% FS ・ Pressure of the measured gas:positive pressure,micro
Stability: 0.01~9.99ppm O2: ±2.5% FS/7d and no current,and the sensor has an absolute zero point,which
Stability: 100~1000ppm O2:±1% FS pressure or negative pressure; 10.0~99.9ppm O2: ±1.5% FS/7d means that the higher the oxygen concentration, the smaller
0.01~9.99ppm O2:±2.5% FS/7d ・ The main components of the measured gas:whether it 100~1000ppm O2: ±1% FS/7d the sensor reaction will be,and the longer the life will be.The
10.0~99.9ppm O2:±1.5% FS/7d Response time: T90<60s(25°C) anode is continuously converted into CO2 in the reaction until
contains CO2,H2S,SO2,NOx,NH3 and other gases.
100~1000ppm O2:±1% FS/7d Power supply: 85~264VAC,50/60Hz the anode is depleted.Just as some fuels are burned out by
Response time: T90<60s(25°C) Signal output: 2 sets,4-20mA/0-20mA/0-1V/0-5V/ 0-10V/1-5V, constant oxidation.
Power supply: 85~264VAC,50/60Hz Instructions can freely set mode
Signal output: 4-20mA (default configuration), 0-20mA,0-1V ・Sensor principle:please refer to page 2 of this sample Switch output: 6 sets,Relay contact point capacity:24V DC,0.2A
Instructions
0-10V,can freely set mode book; Communication: RS485(standard)/RS232(optional) ・Application field and ordering instructions:please refer
Switch output: Two-way alarm,Relay contact point capacity: 24V External control: quantity:5 sets,control signal 9~28VDC to page 1 of this sample book;
DC,0.2A
・Interference effects of various gases on measurement:
Enoirment ・Interference effects of various gases on measurement:
Communication: RS485(standard)/RS232(optional) please refer to page 15 of this sample book. please refer to page 15 of this sample book.
temperature: -10~45°C Environment Humidity:<90%RH

01 02
On-line trace oxygen analyzer On-line trace oxygen analyzer

CI-PC96/961 CI-PC99
Trace oxygen analyzer Trace oxygen analyzer

CI-PC96/CI-PC961 is a micro-oxygen analyzer,which CI-PC99 analyzer is suitable for the measurement of


is an intelligent analyzer based on microprocessor.The trace oxygen in various industrial processes and provides
sensor used in this system is a fuel cell oxygen sensor,which the display of oxygen concentration.It takes microcontroller
can measure 0-25% oxygen concentration, but in the envir technology as its core and fuel cell oxygen sensor as its
-onment of 0-1000ppm oxygen concentration,the measur measuring unit.It has the characteristics of intelligence,high
-ement is the best. precision,fast response and good stability.It uses 128*64
LCD screen as the window, showing intuitive,rich content,
various parameters can be set freely by users,and the
operation is simple.

Product Features Technical Specifications Product Features Technical Specifications


・The new structure of the test chamber is adopted to Environment ・Using the latest touch button technology,it is easy to Environment
facilitate the field replacement of the sensor; temperature: 0~45°C Environment Humidity:<80%RH operate and has a long service life. temperature: 0~45°C Environment Humidity:<80%RH
・Over range protection function:when the oxygen concen- Sample gas ・Digital temperature compensation function:it adopts Sample gas
tration is higher than the protection value,the gas circuit pressure: atmospheric conditions±10% (Gas outlet the most advanced temperature compensation method pressure: atmospheric conditions±10% (Gas outlet
should be atmospheric conditions) should be atmospheric conditions)
will be cut off automatically,so as to avoid the sensor's in the world,and its temperature compensation effect is
Analyzer size: CI-PC96: When equipped with a suction pump,it is
performance and life being affected by the environ- world leading. negative pressure and micro-positive pres-
L×W×D=144mm×144mm×251mm
ment with high oxygen concentration for a long time. CI-PC961: ・Over-voltage protection function:when the internal Analyzer weight: sure.
・Pressure protection function:When the pressure in the L×W×D=144mm×144mm×190mm pressure of the gas circuit exceeds the protection about 7 kg (weight varies depending on
test chamber exceeds the set range,the gas path will be range,the gas circuit will be cut off automatically to configuration)
cut off automatically to avoid the damage of the sensor Applications avoid the damage of the sensor due to too large or too
due to too large or too small pressure. small pressure; Applications
・ Air separation;
・Pressure compensation function:compensate the oxygen ・Pressure compensation function:reduce the influence ・ Air separation;
・ Gas production and testing;
concentration value according to the pressure in the of pressure on the oxygen concentration in sensor test, ・ Sample gas detection in gas production and
・ Protection gas detection in semiconductor industry;
test chamber,eliminate the influence of pressure on the making the measurement more accurate. manufacturing;
oxygen concentration measured by the sensor, make ・ Protection gas detection in reflow/wave soldering;
・Over range protection function:concentration protec- ・ Detection of oxygen concentration in protective gases
the test more accurate and more accurate; ・ Gas detection in food production process; tion function,when the oxygen concentration exceeds in semiconductor industry;
・Temperature compensation function:automatic tempera- ・ Gas detection in petrochemical process; the protective concentration, the gas path will be cut off ・ Detection of oxygen concentration in gases in
ture compensation,eliminating the influence of environ- ・ Detection of oxygen concentration in inert gas and hyd automatically,so as to avoid the influence of the sensor's petrochemical process;
mental temperature; -rocarbon gas,etc. performance and life in the environment with high ・ Detection of oxygen concentration in protective gas in
・Automatic Calibration Function:It has advanced automat- reflow/wave soldering;
oxygen concentration for a long time.;
・ Detection of oxygen concentration in gases during
ic calibration function,and the calibration can be complet- ・The new structure of the test chamber and the use of
Order Information food production,packaging and storage;
ed automatically after connecting with external calibra- digital sensors can not only be replaced on site,but also ・ Detection of oxygen concentration in inert gas and
tion equipment. ・ Pneumatic connection mode:A,Φ 6 hose (standard); B, need no calibration. hydrocarbon gas,etc.
connecting by using 1/4 "Φ 3 stainless steel cutting ・Activated carbon filter:the activated carbon filter on the
Technical Specifications side of the analyzer is a patented product of our compa-
ferrule;C,connecting by using 1/8 "- Φ 3 stainless steel Order Information
Measure range: 0~10/100/1000ppm/1%/25% O2 ny,with a filtration diameter up to 5um.
cutting ferrule;
Sensor principle: fuel cell type ・ Whether to configure pumps and needle valves:needle
Accuracy: 0.01~9.99ppm O2:±5% FS
・ Filter:CI-GF2800,AF2000; Technical Specifications valves are recommended when the gas source is
10.0~99.9ppm O2:±3% FS ・ Pressure of the measured gas:positive pressure,micro Measure range: 0~10/100/1000ppm/1%/25% O2 positive pressure,and pumps are recommended when
100~1000ppm O2:±2% FS pressure or negative pressure; Accuracy: 0.01~9.99ppm O2:±5% FS the gas source is micro-pressure or negative pressure.
Repeatability: 0.01~9.99ppm O2:±2.5% FS ・ The main components of the measured gas:whether it 10.0~99.9ppm O2:±3% FS ・ Whether to configure batteries:it can be used as
10.0~99.9ppm O2:±1.5% FS 100~1000ppm O2:±2% FS portable instrument after battery is configured;
contains CO2,H2S,SO2,NOx,NH3 and other gases.
100~1000ppm O2:±1% FS Repeatability: 0.01~9.99ppm O2:±2.5% FS ・ The main components of the measured gas:whether it
Stability: 0.01~9.99ppm O2:±2.5% FS/7d 10.0~99.9ppm O2:±1.5% FS contains CO2,H2S,SO2,NOx,NH3 and other gases.
・ Activated carbon filter can be selected and the filter
10.0~99.9ppm O2:±1.5% FS/7d Instructions 100~1000ppm O2:±1% FS
diameter can reach 5um.
100~1000ppm O2:±1% FS/7d Stability: 0.01~9.99ppm O2:±2.5% FS/7d
Response time: T90<60s(25°C) ・Sensor principle:please refer to page 2 of this sample book; 10.0~99.9ppm O2:±1.5% FS/7d
Switch output: 2 sets,Relay contact point capacity:24V ・Interference effects of various gases on measurement: 100~1000ppm O2:±1% FS/7d Instructions
DC,0.2A please refer to page 15 of this sample book. Response time: T90<60s(25°C)
Power supply: CI-PC96:85~264VAC 50/60Hz Power supply: 220VAC±10%,50/60Hz ・Sensor principle:please refer to page 2 of this sample
CI-PC961:24VDC,Power consumption Communication: RS485(standard)/RS232(optional) book;
less than 20VA Signal output: 2 sets,Relay contact point capacity: ・Interference effects of various gases on measurement:
Communication: RS485(standard)/RS232(standard) 24V DC,0.2A please refer to page 15 of this sample book.

03 04
On-line trace oxygen analyzer On-line trace oxygen analyzer

CI-PC16 CI-PC125
Frequency conversion ion Frequency conversion
flow oxygen analyzer ion flow oxygen analyzer
CI-PC16 analyzer is based on microprocessor. CI-PC125 frequency conversion ion flow oxygen
Intelligent oxygen analyzer with frequency conversion ion analyzer takes microcontroller technology as the core
flow oxygen sensor as measuring unit,and it has the and adopts the world's most advanced sensor as the
characteristics of intelligence and high precision.It is measurement unit.It is an oxygen analyzer with first-class
suitable for accurate measurement of oxygen concentra- technology and high performance,which suitable for the
tion in 0-25.00% nitrogen-oxygen mixture gas in various measurement of oxygen content in mixed gases in a
industries and environments. variety of industries and environments.It has analog signal
output,alarm switch output,communication, external control
and other functions.

Product Features Technical Specifications Product Features Technical Specifications


・It has the characteristics of intelligence,good stabili- Sample gas ・The most advanced sensor in the world is used as signal output: 0-10V/1-5V, you can set the mode freely
ty,high reliability and long calibration cycle. pressure: atmospheric conditions±10% (Gas outlet measuring unit,which has high accuracy and long cali- Signal output: 2 sets,Relay contact point capacity:24V
・Oxygen concentration,various data and the working should be atmospheric conditions) bration period. DC,0.2A
state of the instrument are displayed by 128*64 LCD Analyzer size: L×W×H=144mm×144mm×251mm Environment
・The electronic flowmeter with our patented technology
window. Installation mode:disc mounted temperature: -10~50°C Environment Humidity:<80%RH
Install hole size: L×W=136mm×136mm is internationally advanced in quality and performance.
・The display is intuitive and the operation is simple. Sample gas
・The temperature of the sensor is controlled at 750°C
・The surface of the window is covered with a piece of pressure: atmospheric conditions±10% (Gas outlet
automatically and temperature compensation is should be atmospheric conditions)
toughened glass to protect the LCD screen and keys.
carried out to make the test more stable. Sample flow rate: 1.5~2L/min
・The latest touch button technology is adopted to prolong
・Before leaving the factory,the analyzer has been tested Analyzer weight: about 3.85kg
the service life of keys.
strictly against electromagnetic interference and static Analyzer size: L×W×H=300mm×242mm×125mm
・Menu lock switch:prevent misoperation from affecting Applications electricity,and reached the military standard.
analyzer;
・Data storage function:recording test data regularly and ・ Air separation; ・Alarm function:When the oxygen concentration deviates
querying and storing data quickly; ・ Gas production and testing; from the alarm value or runs incorrectly,the alarm value Applications
・Alarm function:When the oxygen concentration deviates ・ Protection gas detection in semiconductor industry; can be set arbitrarily within the full range.
・Communication function:RS232/RS485 is used to ・ Air separation;
from the alarm value or the operation is wrong,the ・ Protection gas detection in reflow/wave soldering;
communicate directly with computer or other digital ・ Sample gas detection in gas production and manufacturing;
alarm will be issued. ・ Gas detection in food production process;
communication equipment. ・ Detection of oxygen concentration in protective gases in
・Communication function:using RS232/RS485 two-way Gas detection in petrochemical process;
・ semiconductor industry;
communication,which can communicate directly with
・ Detection of oxygen concentration in inert gas, etc. ・ Detection of oxygen concentration in gases in petrochemical
computer or other digital communication equipment. Technical Specifications process;
Technical Specifications Measure range: 0~25.00% O2 ・ Detection of oxygen concentration in protective gas in
Accuracy: 0.01~99.9 ppm ±5ppm reflow/wave soldering;
Sensor principle: Frequency conversion ion flow
100~999.9ppm ±3%FS ・ Detection of oxygen concentration in gases during food
Measure range: 0~25% O2 Order Information production,packaging and storage;
Accuracy: 0.01~99.9 ppm ±5ppm 1000~9999 ppm ±3%FS
100~999.9ppm ±3%FS ・ Pneumatic connection mode:A,Φ6 hose (standard); 1.00%~25.00% ±3% of the measured value ・ Detection of oxygen concentration in inert gas,etc.
1000~9999 ppm ±3%FS B,connecting by using 1/4-Φ 6 stainless steel cutting Repeatability: 0.01~99.9 ppm ±2.5ppm
1.00%~25.00 % ±3% of the measured value 100~999.9ppm ±1.5%FS
Repeatability: 0.01~99.9 ppm ±2.5ppm
ferrule;C,connecting by using 1/8 -Φ3 stainless steel
1000~9999 ppm ±1.5%FS
Order Information
100~999.9ppm ±1.5%FS cutting ferrule; ・ Pneumatic connection mode:A,Φ6 hose (standard);B,con-
1.00%~25.00% ±1.5% of the measured value
1000~9999 ppm ±1.5%FS ・ Pressure of the measured gas:positive pressure,micro Stability: 0.01~99.9 ppm ±2.5ppm/7d necting by using 1/4-Φ6 stainless steel cutting ferrule; C,
1.00%~25.00 % ±1.5% of the measured value pressure or negative pressure; 100~999.9ppm ±1.5%FS/7d connecting by using 1/8 -Φ3 stainless steel cutting ferrule;
Stability: 0.01~99.9 ppm ±2.5ppm/7d ・ Sample gas should not contain the following substances: 1000~9999 ppm ±1.5%FS/7d ・ Filter:GF2800,AF2000;
100~999.9ppm ±1.5%FS/7d 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc. 1.00%~25.00% ±1.5% of the measured value ・ Pressure of the measured gas:positive pressure,micro
1000~9999 ppm ±1.5%FS/7d /7d pressure or negative pressure;
1.00%~25.00% ±1.5% of the measured value 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
Response time: T90<20s (after full preheating) ・ Sample gas should not contain the following substances:
/7d 3.Fluxes such as rosin;
Sensor 1.Corrosive gases,such as HF,Cl2,HCl,etc.
Response time: T90<20s(after full preheating) 4.Reductive components and hydrocarbons,such as 2.Toxic substances,such as Si,Pb,P,etc.
temperature: 750°C constant temperature control and
Relay contact ethanol; compensation 3.Fluxes;
point capacity: 24VDC,0.2A 5.Impurities,such as dust. Power supply: 85~264VAC,50/60Hz 4.Reductive components and hydrocarbons,such as ethanol;
Power supply: 85~264VAC,50/60Hz
Communication: RS232(standard)/RS485(optional) Analyzer power 5. Impurities,such as dust.
Environment consumption: 2 sets,4-20mA/0-20mA/0-1V/0-5V/
temperature: -10~50°C Environment Humidity:<80%RH Analog less than 25VA

05 06
On-line trace oxygen analyzer On-line trace oxygen analyzer

CI-PC128/-1 CI-PC12
Frequency conversion Frequency conversion
ion flow oxygen analyzer ion flow oxygen analyzer
The new CI-PC128/-1 series oxygen analyzer (reflow The CI-PC12 analyzer is an intelligent oxygen analyzer
soldering,wave soldering,brazing special) is introduced, with microcomputer as the core and frequency conversion
using frequency ion flow testing principle and combines CI-PC128 ion flow oxygen sensor as the measuring unit. It has the
with the advanced technology in the world.It breaks the characteristics of intelligence and high precision. The
traditional detection mode and pioneers to realize on-line invention is suitable for accurate measurement of oxygen
detection without reference gas and is not affected by ambient
concentration in 0-25.00% nitrogen-oxygen mixed gas in
oxygen concentration.The sensor has the characteristics
various industries and environments.
of good interchangeability,no power consumption,high test
accuracy,long calibration cycle,compact size,low power
consumption,stability and reliability. CI-PC128-1(2018)

Product Features Technical Specifications Product Features Technical Specifications


・ It has the characteristics of intelligence,good stability, should be atmospheric conditions) ・It has the characteristics of good stability,high reliabili- Relay contact
high reliability and long calibration cycle. Analyzer size: CI-PC128: ty,long calibration period and intelligence. capacity: 24VDC,0.2A
・ The latest touch button technology is adopted to prolong L×W×H=300mm×270mm×132mm ・Accurate Measurement of Oxygen Concentration in 85~264VAC,50/60Hz
Power supply:
the service life of keys. CI-PC128-1:
L×W×H=300mm×242.5mm×125mm 0~25% Nitrogen (N2) Oxygen (O2) Mixture Gas Communication: RS232(Standard)/RS485(Optional)
・ Measure the relative pressure inside the air path and
Install hole size: CI-PC128: ・Many control modes of pumping pump,flexible switch ambient
check whether the air path is blocked.
L×W=235.5mm×129mm pumping pump,prolong the service life. temperature: -10~50°C environmental humidity:less
・ Menu lock switch:to prevent the impact of wrong CI-PC128-1:
operation on the analyzer; L×W=200mm×124mm ・Menu lock switch:Preventing Misoperation from Affecting than 80%RH
・ Alarm function:When the oxygen concentration deviates Analyzer sample pressure: pressure±10% (Outlet should be atmo-
from the alarm value or runs incorrectly,the alarm value ・Alert Feature:When the oxygen concentration deviates spheric pressure)
can be set freely within the full range.
from the alarm value or the operation error,the alarm Analyzer size: L×W×H=290mm×167mm×119mm
・ Communication function:RS232/RS485 two-way com Applications value can be set freely in the full range. Analyzer weight: self-weight 3kg,after packaging around
munication,can communicate directly with computer or
other digital communication equipment. ・ Air separation; ・Communication Features:RS232/RS485 is used to 4.5kg
・ Gas production and testing; communicate directly with computer or other digital
・ Protection gas detection in semiconductor Applications
Technical Specifications communication equipment.
industry; ・ Air separation
Sensor principle:Frequency conversion ion flow ・ Protection gas detection in reflow/wave ・Isolated analog output:Freely setting 0~20mA/4~20mA
Measure range: 0~25.00% O2 /0~1V/0~5V/0~10V/1~5V analog output mode ・ Gas Production Manufacturing Inspection
soldering;
・ ・ Protection gas detection in semiconductor industry
Accuracy: 0.01~99.9 ppm ±5ppm ・Small size,simple structure,easy to use and maintain
・ Gas detection in food production process;
100~999.9ppm ±3%FS ・ Gas detection in petrochemical process; ・ Protection Gas Detection in Reflow Soldering/Peak
1000~9999 ppm ±3%FS Detection of oxygen concentration in inert gas, Soldering
1.00%~25.00% ±3% of the measured value etc. Technical Specifications
・ Gas Detection in Food Production Process
Repeatability: 0.01~99.9 ppm ±2.5ppm measuring ・ Gas Detection in Petrochemical Process
100~999.9ppm ±1.5%FS
range: 0~25.00% O2 ・ Oxygen concentration detection in inert gases,etc.
1000~9999 ppm ±1.5%FS
1.00%~25.00% ±1.5% of the measured value response time: 0.01~99.9 ppm: ±5ppm
Order Information 100~999.9ppm: ±3%FS
Stability: 0.01~99.9 ppm ±2.5ppm/7d Order Information
100~999.9ppm ±1.5%FS/7d ・ CI-PC128-X(2018) 1000~9999 ppm:±3%FS
1000~9999ppm ±1.5%FS/7d 1.00%~25.00%:measured ±3% ・ Gas Path Connection Mode:A,Φ6 hose connection
2018:OLED screen
1.00%~25.00% ±1.5% of the measured (standard) B,1/4"-Φ6 stainless steel ferrule connection
Blank:LCD screen sensor principle: 0.01~99.9 ppm ±2.5ppm
value /7d C,1/8"-Φ3 stainless steel ferrule connection;
-1:small case
100~999.9ppm: ±1.5%FS ・ Filter:GF2800,AF2000;
Response time: T90<20s(after full preheating) Blank:large case
Relay contact 1000~9999 ppm:±1.5%FS
CI-PC128 Series Oxygen ・ Pressure of the measured gas:Positive,Micro,or Negative
point capacity: 24VDC,0.2A Difference: 1.00%~25.00%: measured ±1.5%
・ The sample gas cannot contain the following sub-
Analyzer
Power supply: 85~264VAC,50/60Hz 1.OLED screen has longer service life stability: 0.01~99.9 ppm ±2.5ppm/7d stances:
Calibration cycle:recommended once a year 2.Sample book for small and large chassis 100~999.9ppm: ±1.5%FS/7d 1.corrosive gases such as HF,Cl2,HCl;
Communication: RS232(standard)/RS485(optional) outline size and installation size.
1000~9999ppm: ±1.5%FS/7d 2.toxic substances,such as Si,Pb,P,etc.;
Environment ・ For more information on orders, please refer to page
temperature: -10~50°C Environment Humidity: <80%RH 6 of this sample book. 1.00%~25.00%: measured±1.5%/7d 3.Welders;
Sample response time: T90<20s(Fully heated) 4.Reducing components,hydrocarbons,such as ethanol;
gas pressure: atmospheric conditions±10% (Gas outlet sensor principle: frequency conversion ion flow 5.Impurities,such as dust.

07 08
On-line trace oxygen analyzer On-line trace oxygen analyzer

CI-PC121 CI-PC129
Frequency conversion Trace oxygen analyzer
ion flow oxygen analyzer
CI-PC121 oxygen analyzer takes microprocessor as its CI-PC129 oxygen analyzer combines the most
core and frequency conversion ion flow oxygen sensor as advanced digital proportional valve in the world.Both of
its measuring unit.It has the characteristics of intelli- them are assembled in a chassis,which makes the instru-
gence,high precision,fast response,good stability and ment possess all functions and characteristics of both
comprehensive function.It is suitable for accurate measure- oxygen analyzer and digital proportional valve.It can meet
ment of oxygen concentration in nitrogen-oxygen mixture the requirements of fast response and high precision
in various industries and environments.The function of control in industrial process control,and has complete
self-diagnosis function.The digital proportional valve has
the output port of the analyzer can be flexibly configured
the characteristics of high control precision,short response
to meet the different needs of users.
time and no dead zone,which greatly reduces the user's
gas consumption cost.
Product Features Technical Specifications Product Features Technical Specifications
・Overvoltage detection function:Real-time detection Sample gas ・According to the requirement of oxygen concentration Measure range: 0~10/100/1000ppm/1%/25.00% O2
of the internal gas pressure of the analyzer,it is pressure: atmospheric conditions±10% (Gas outlet and concentration control,the analyzer adjusts the Accuracy: 0.01~9.99ppm O2:±5% FS
easy to judge whether the gas path is blocked or not; should be atmospheric conditions) opening of digital proportional valve to control the flow 10.0~99.9ppm O2:±3% FS
・Structural design:The display area and key area of Analyzer size: L×W×H=264mm×190mm×159mm rate of nitrogen filling in the process,so as to obtain and 100~1000ppm O2:±2% FS
the analyzer are covered with toughened glass, maintain the range of oxygen concentration required by Repeatability: 0.01~9.99ppm O2:±2.5% FS
Floor installation
which has high strength and is not easy to be the measured working conditions.Its advantage is to 10.0~99.9ppm O2:±1.5% FS
size: L×W=210mm×195mm(Φ5 x 4 bolt hole)
damaged. maintain the maximum quality of end products with the 100~1000ppm O2:±1% FS
Analyzer weight: about 3.7-4.1kg and 4.5-5.5 kg after Stability: 0.01~9.99ppm O2:±2.5% FS/7d
・Touch key:The analyzer uses the latest touch key packing. minimum consumption of nitrogen and reduce scrap
and rework. 10.0~99.9ppm O2:±1.5% FS/7d
technology,which is easy to operate and prolongs
100~1000ppm O2:±1% FS/7d
the service life of the key. ・The analyzer has the function of PID parameter self-set-
Response time: T90<60s(25°C)
・Three-way alarm switch output,compact size,simple Applications ting. Users only need to input the oxygen concentration
Sensor: Fuel cell oxygen sensor
structure,easy to carry and maintain. control value of the measured environment into the Power supply: 85~264VAC,50/60Hz
・Air separation; analyzer and start the parameter self-setting. Environment
・Gas production and testing; ・The analyzer has digital communication,users can temperature: -10~50°C,Environment Humidity:<80%RH
Technical Specifications ・Protection gas detection in semiconductor industry; operate and control the instrument through the instru- Communication: RS485(standard)/RS232(optional)
・Protection gas detection in reflow/wave soldering; ment keys and display or PC control software; Switch output: 2 sets,(One group of state alarm and one
Sensor principle: Frequency conversion ion flow ・In order to reduce the cost of production gas,some SMT
・Gas detection in food production process; group of concentration alarm)
Measure range: 0~25.00% O2 manufacturers will install their own nitrogen production Relay contact
・Gas detection in petrochemical process;
Accuracy: 0.01~99.9 ppm: ±5ppm machines,but in order to achieve the same purity as point capacity: 24V DC,0.2A
100~999.9ppm: ±3%FS ・Detection of oxygen concentration in inert gas,etc.
liquid nitrogen,from the economic point of view,users Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V
1000~9999 ppm: ±3%FS will often add carbon or hydrogen purification for (You can set the mode freely).
1.00%~25.00 %: ±3% of the nitrogen production machines.After carbon purifica- The load: less than 500 Ω
Order Information External control: 1 set,control signal 9~28VDC
measured value tion,there will be CO,CO2,N2,O2 and other components in
Repeatability: 0.01~99.9 ppm ±2.5ppm ・ Pneumatic connection mode: A,Φ6 hose (standard); the product gas.There will be H2,N2,O2 and other Sample gas
100~999.9ppm: ±1.5%FS B,connecting by using 1/4-Φ6 stainless steel cutting components in the gas after hydrogen purification. pressure: atmospheric conditions±10% (Gas outlet
1000~9999 ppm: ±1.5%FS CI-PC129 can accurately measure in this working condi- should be atmospheric conditions)
ferrule;C,connecting by using 1/8 -Φ3 stainless steel
tion without interference from CO,CO2,H2 and gas. Sample flow rate: 1.5~2L/min
1.00%~25.00 %: ±1.5% of the cutting ferrule;
・Digital temperature compensation function:The most Analyzer size: L×W×H=310mm×275mm×190mm
measured value ・ Filter:GF2800,AF2000;
Stability: 0.01~99.9 ppm ±2.5ppm/7d advanced temperature compensation method of micro
・ Pressure of the measured gas:positive pressure,micro
100~999.9ppm: ±1.5%FS/7d oxygen analyzer in the world,its temperature compen- Order Information
pressure or negative pressure;
1000~9999ppm: ±1.5%FS/7d sation effect is the world's leading;
・ Sample gas should not contain the following When ordering,please indicate the main components of
・Pressure compensation function:eliminating the influence
1.00%~25.00%: ±1.5% of the substances: the measured gas:whether it contains CO2,H2S,SO2,NOx,
of pressure on the oxygen concentration of the sensor,the
measured value /7d 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S, etc. NH3,etc.
measurement accuracy is higher;
Response time: T90<20s (after full preheating)
2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc. ・Over range protection function:that is concentration
Relay contact
3.Fluxes such as rosin; protection function,when the oxygen concentration Instructions
point capacity: 24VDC,0.2A
4.Reductive components and hydrocarbons,such as exceeds the set value,the gas path will be cut off ・Sensor principle:please refer to page 2 of this sample
Power supply: 85~264VAC,50/60Hz automatically,so as to avoid the sensor's performance
ethanol; book;
Communication: RS232(standard)/RS485(optional) and life being affected by long time in the environment
5.Impurities,such as dust. ・Interference effects of various gases on measurement:
Environment with high oxygen concentration. please refer to page 15 of this sample book.
temperature: -10~50℃
Environment Humidity: <80%RH

09 10
On-line trace oxygen analyzer On-line trace oxygen analyzer

CI-PC95/-1 CI-PC95-2
Explosion-proof trace Explosion-proof trace
oxygen analyzer oxygen analyzer
The case of CI-PC95 /-1 explosion-proof micro oxygen The shell of CI-PC95-2 explosion-proof micro oxygen analyzer
analyzer is designed with flameproof design.The flame- is designed with flameproof design.The flameproof sign of Ex
proof sign of Ex element is Exd II C.It can be used in element is Exd II CT6,which is the whole flameproof structure.
dangerous environment of zone 1 and zone 2 formed by Because the analyzer has flameproof explosion-proof struc-
explosive gases and their mixtures containing class II C ture,so in addition to meet the general requirements of explo-
T6 and below.The instrument is a new generation of micro
sion prevention,can also be used in dangerous environments
oxygen analyzer based on electrochemical sensors.It
CI-PC95-1 containing explosive gases and their mixtures of Class II C T6
uses digital processing technology, including calibration,-
linearization,switching output control,current/voltage and below.Fuel cell sensor is used as measuring unit in the
output,parameter setting and other functions. The analyz- analyzer,which can accurately measure oxygen concentration
er has the functions of alarm output,analog signal in various environments and provide oxygen concentration
output,communication and external control. CI-PC95 display for users.
Product Features Technical Specifications Product Features Technical Specifications
・With microprocessor as the core, it has good long-term Response time: T90<60s(25°C) ・It combines microcontroller with digital processing Switch output: Alarm value:1
stability and high reliability. Protection level: IP64 technology to resist cross-interference and is stable and Relay contact point capacity:24V DC,0.2A
・The electrochemical sensor is used as the measuring Calibration cycle: one year (recommended) reliable. Environment
unit with high accuracy and long calibration period. Power supply: 24V DC ・Fuel cell sensor has high precision and good stability. temperature: -10~+45°C Environment Humidity:<90%RH
・Digital temperature compensation function: The most Analyzer power With infrared remote-control function,the analyzer can Sample gas
advanced temperature compensation method of micro consumption: <15VA be operated by remote control. pressure: atmospheric conditions±10% (Gas outlet
oxygen analyzer in the world, its temperature compen- Communication: RS485(standard)/RS232(optional) ・Menu lock switch:to prevent misoperation to change the should be atmospheric conditions)
sation effect is the world's leading; Environment parameters of the analyzer and affect its normal opera- Sample flow
・Over-voltage protection: When the pressure in the test temperature: -10~45°C Environment Humidity:<90%RH
tion; rate: 1.5~2L/min
chamber exceeds the set range, the gas path is cut off Switch output: Alarm value:1
・The explosion-proof design is adopted,and the explo- Inlet and outlet:1/4-inch NPT internal thread,standard 6.5
automatically to avoid the damage of the sensor due Relay contact point capacity:24V DC,0.2A
sion-proof grade reaches Ex II CT6. hose joint
to too much or too little pressure (negative pressure). Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V
・Alarm function:When the oxygen concentration deviates Sensor life: more than 2 years (normal use)
・Pressure compensation function: eliminate the (You can set the mode freely).
from the alarm value,the alarm value can be set arbitrari- Instrument life: more than 5 years (normal use)
influence of pressure on the oxygen concentration of The load: less than 500Ω
sensor, which makes the measurement more accurate Sample gas ly in the full range. Weight: Net weight 2.0 kg
and precise. pressure: atmospheric conditions±10% (Gas outlet ・Communication function:RS485/RS232,only one of the Installation: wall-mounted
・Over range protection function: concentration protec- should be atmospheric conditions) analog signals,RS485 and RS232 can be selected.
tion function, when the oxygen concentration exceeds Sample flow rate: 1.5~2L/min
Technical Specifications
the set value, the gas path will be cut off automatically CI-PC95: L×W×H=300×200×175mm
Applications
to avoid the sensor performance and life affected by Flow meter:Selection Sensor: Fuel cell oxygen sensor ・Gas production and testing;
long time in the environment with high oxygen concen- CI-PC95-1: L×W×H=375×315×179mm Measure range: 0~10/100/1000ppm/1%/25.00% O2 ・Protection gas detection in semiconductor industry;
tration; Level of explosion-proof:Exd || CT6 Accuracy: 0.01~9.99ppm O2:±5%FS ・Gas detection in food production process;
・The unique solenoid valve is used to protect the gas (certification) 10.0~99.9ppm O2:±3%FS ・Gas detection in petrochemical process;
path, and the seal is reliable, and the state of the gas 100~1000ppm O2:±2%FS ・Detection of oxygen concentration in inert gas and
path can be automatically controlled by the micropro- Applications Repeatability: 0.01~9.99ppm O2:±2.5%FS hydrocarbon gas,etc.
cessor. 10.0~99.9ppm O2:±1.5%FS
・Air separation;
・The new structure of the test chamber and the use of 100~1000ppm O2:±1%FS
・Gas production and testing;
digital sensors can not only be replaced on site, but also
・Protection gas detection in semiconductor industry; Stability: 0.01~9.99ppm O2:±2.5%FS/7d Order Information
do not require the use of standard gas for calibration. 10.0~99.9ppm O2:±1.5%FS/7d
・Gas detection in food production process; When ordering,please indicate the main components of
・Gas detection in petrochemical process; 100~1000ppm O2:±1%FS/7d the measured gas:whether it containsCO2,H2S,SO2,NOx,
Technical Specifications ・Detection of oxygen concentration in inert gas and Response time: T90<60s(25°C) NH3,etc.
Sensor: Electrochemical sensor hydrocarbon gas, etc. Explosion-
Accuracy: 0.01~9.99ppm O2:±5% FS proof grade: Exd || CT6
10.0~99.9ppm O2:±3% FS Instructions Protection level: IP65 Instructions
100~1000ppm O2:±2% FS Calibration cycle: one year (recommended)
・Order Information:Please refer to page 12 of this Power supply: 24VDC ・Sensor principle:please refer to page 2 of this sample
Repeatability: 0.01~9.99ppm O2:±2.5% FS
・sample book. Analyzer power: <15VA book;
10.0~99.9ppm O2:±1.5% FS
・Sensor principle:please refer to page 2 of this sample consumption: RS485/RS232 ・Interference effects of various gases on measurement:
100~1000ppm O2:±1% FS
book; please refer to page 15 of this sample book.
Stability: 0.01~9.99ppm O2:±2.5% FS/7d Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/ 0-10V/
10.0~99.9ppm O2:±1.5% FS/7d Interference effects of various gases on measurement: 1-5V (You can set the mode freely).
100~1000ppm O2:±1% FS/7d please refer to page 15 of this sample book. The load: less than 500 Ω

11 12
On-line trace oxygen analyzer On-line trace oxygen analyzer

GNL-STM3 P860
Oxygen analyzer Oxygen/nitrogen analyzer
The GNL-STM3 oxygen analyzer is an intelligent P860 series nitrogen purity analyzer is an on-line analyz-
analyzer based on microprocessor.It can measure oxygen er. It adopts a new type of intelligent detection instrument
concentration in nitrogen-oxygen mixed gas containing which combines the advanced ion current sensor and
(O2)0~1000PPm accurately. It has two programmable single chip computer in the world. It can be used to detect
alarm points, one programmable current (4-20mA) output the oxygen concentration in nitrogen-oxygen mixture and
provide a display of the oxygen concentration value,or a
and two programmable alarm signals (ALRM) output.
display of the nitrogen concentration value after calculat-
ing the nitrogen concentration value by using the oxygen
concentration value (N2%=100-O2%).

Product Features Technical Specifications Product Features Technical Specifications


・The oxygen sensor of imported chemical battery has long compensation: The temperature sensor is embedded in ・A new type of long-life ion flow sensor has high sensitivity Sensor principle: Ion flow oxygen sensor
life,high precision and fast response time. the sensor cavity, and the temperature and fast response speed. Accuracy: 10ppm~100ppm O2 ±5%FS
・It can be used to measure trace oxygen in carbon dioxide,hy- information is fed back to the micropro- ・The value of nitrogen concentration can be calculated accord- 10ppm~2% O2 ±2%FS
drogen and other gases. cessor and the temperature compensa- ing to the oxygen concentration,and the corresponding 10ppm~21% O2 ±1.5%FS
・Using a unique built-in protective gas path,automatically cut tion is carried out display can be provided. Stability: ±2%FS/7d
off the gas path when the power is shut down or cut Ambient ・Alarm function:When the concentration of oxygen/nitro- Response time: T90≤20s
off,effectively protect the sensor,avoiding the sensor from temperature: 0~45°C Environmental humidity:less than gen deviates from the alarm value,the alarm will be sent Measuring method: gas inlet type
being exposed to the air for a long time to affect the life of 90%RH out and the alarm switch signal will be output.The alarm Gas flow rate: 400-600ml/min
the sensor; Sample pressure: Atmospheric pressure ±10% (air outlet is value can be set arbitrarily in the full range. Sample gas pressure:atmospheric conditions±10% (Gas outlet
・All-Chinese man-machine dialog menu,intuitive and conve- atmospheric pressure) ・Analog output:Isolated 4-20 mA current signal output. should be atmospheric conditions)
nient; Sensor room: Nickel plating on aluminum alloy and Environment
・Timing automatic storage,can view historical data at any sealing of screwing type cover
Model Specifications temperature: 0~45°C
time; Analyzer Environment
・Automatic temperature compensation to eliminate environ- dimension: L×W×H=400mm×300mm×200mm Display mode model Measuring range humidity: <80%RH
mental temperature effects P860-3O 1000ppm~21.0% O2 Analog output: Programmable 4-20 mA Current Output
・Upper and lower bounds of analog output can be set arbitrari- Display of oxygen P860-4O 100ppm~21.00% O2 (External Load < 500 Ω)
ly in full range
Order Information concentration Relay contact point
P860-5O 10ppm~21.000% O2
It can be widely used in brazing furnace,air separation capacity: 24VDC,0.2A
P860-3N 79.0%~99.9% N2
Technical Specifications and liquefaction,such as the measurement and control of Display of nitrogen
P860-4N 79.00%~99.99% N2
Power supply: 220VAC±10%,50/60Hz or 24VDC
Measurement oxygen concentration in PSA nitrogen making equipment; concentration Analyzer power
P860-5N 79.000%~99.999% N2
range: 0~10/100/1000ppm,0~25% manual chemical process; protective gas of high temperature consumption: <10VA
adjustment within the measurement range sintering furnace such as magnetic material;protective Sensor life: more than 2 years (normal use)
Corresponding sensor type of analyzer:
0.01~9.99ppm O2:±5% FS gas of electronic industry; glass, building material indus- Instrument life: more than 5 years (normal use)
Accuracy: 10.0~99.9ppm O2:±3% FS try, etc. P860-3N OLZL04 Packing box size: L×W×H=230mm×230mm×150mm
100~1000ppm O2:±2% FS P860-3O OLZL04 Installation size: L×W×D=51mm×76mm×167mm
0.01~9.99ppm O2:±2.5% FS P860-4N OLZL03
Repeatability: 10.0~99.9ppm O2:±1.5% FS Order Information P860-4O OLZL03
100~1000ppm O2:±1% FS ・ Pneumatic connection mode:A,Φ6 hose (standard); P860-5N OLZL02 Order Information
0.01~9.99ppm O2:±2.5% FS/7d
P860-5O OLZL02
B,connecting by using 1/4 "Φ6 stainless steel cutting ・ Pressure of the measured gas:positive pressure,micro
Stability: 10.0~99.9ppm O2:±1.5% FS/7d ferrule;C,connecting by using 1/8 "-Φ3 stainless steel Applications pressure or negative pressure;
100~1000ppm O2:±1% FS/7d cutting ferrule; ・ Sample gas should not contain the following substanc-
T90<60s(25°C) ・ Air separation industry;
・ Filter:GF2800,AF2000; ・ Chemical and smelting industries; es:
Response time: 1.Corrosive gases,such as HF,Cl2,HCl,etc.
・ Pressure of the measured gas:positive pressure,micro ・ Detection of oxygen concentration in high temperature
Sensor Chemical battery 2.Toxic substances,such as Si,Pb,P,etc.
pressure or negative pressure; furnace;
principle: 3.Reductive components and hydrocarbons,such as
・ The main components of the measured gas:whether it ・ Detection of oxygen concentration in protective gas of
Relay contact 24VDC,0.2A semiconductor; ethanol;
capacity: AC220V±10% 50/60Hz contains CO2,H2S,SO2,NOx,NH3 and other gases.
・ Cultivation of plants and animals,determination of oxygen 4. Impurities,such as dust.
Power supply: Nitrogen,Hydrogen,Helium,Argon and concentration in processing and storage of vegetables
Background gas: Hydrocarbon Gases (if CO2,H2S,SO2,NOx, Instructions and food; Instructions
NH3,etc.are included) ・Sensor principle:please refer to page 2 of this sample book; ・ Determination of oxygen concentration in family,ship, Principle:please refer to page 46 of this sample
Automatic ・Interference effects of various gases on measurement: please underground command center,tunnel,deep well,civil air
book;
temperature refer to page 15 of this sample book. defense engineering, city tunnel,etc.

13 14
Portable trace oxygen analyzer Portable trace oxygen analyzer

GNL-B1A CI-PC93
Portable trace oxygen Portable trace oxygen
analyzer analyzer
GNL-B1A portable trace oxygen analyzer uses fuel cell CI-PC93 trace oxygen analyzer is an intelligent analyz-
oxygen sensor as measuring unit,which has the charac- er based on microprocessor.The sensor used in this system
teristics of high accuracy and good stability.The analyzer is a fuel cell oxygen sensor,which can measure 0-25%
can measure 0-25% oxygen concentration, which is the oxygen concentration.The sensor has the best measure-
best in the environment of 0-1000ppm oxygen concentra- ment in the environment of 0-1000ppm oxygen concen-
tion. tration,and is mainly used to detect ppm-level oxygen in
various gases.

Product Features Technical Specifications Product Features Technical Specifications


・Overvoltage protection function:when the pressure of Response time: T90<60s(25°C) ・Overvoltage protection function:when the pressure of Sample flow rate: 1~1.5L/min (1.2L/min Recommended)
sample gas exceeds the protection range,the gas path will Recovery time: 60 minutes,from air (20.94%) to 10 ppm sample gas exceeds the protection range,the gas path will Sample gas
be cut off automatically to avoid damage of sensor due to Sensor: Fuel cell oxygen sensor be cut off automatically to avoid damage of sensor due to pressure: atmospheric conditions±10% (Gas outlet
too high or too small pressure; Measuring should be atmospheric conditions)
too high or too small pressure;
・Advanced compensation function:The analyzer has the media: nitrogen,hydrogen,helium,argon and Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V
hydrocarbon gases
・Pressure compensation function:eliminate the influence (You can set the mode freely).
functions of pressure compensation and digital tempera-
Charging of pressure on the oxygen concentration of sensor,which Analyzer Size: L×W×H=260.5mm×160mm×194mm
ture compensation to eliminate the influence of pressure
power supply: 220VAC±10%,50/60Hz,when transformer is makes the measurement more accurate and precise. Instrument weight:self-weight 4.7 kg,about 5.7 kg after packaging
and temperature on oxygen concentration measurement.
・Overrange protection function:When the oxygen concen- configured,And 85~264VAC,50/60Hz,when ・Over range protection function:concentration protection
switch power supply is configured. function,when the oxygen concentration exceeds the set
tration is higher than the protection concentration, the gas
path will be cut off automatically,so as to avoid the
Environment value,the gas path will be cut off automatically to avoid the Applications
temperature: -10~45°C Environment Humidity:<80%RH
sensor's life being affected by the environment with high sensor performance and life affected by long time in the It can be widely used in brazing furnace,air separation and
Sample gas
oxygen concentration for a long time. environment with high oxygen concentration; liquefaction,such as oxygen concentration measurement
pressure: atmospheric conditions±10% (Gas outlet
・The unique solenoid valve can protect the gas path:the ・The unique solenoid valve is used to protect the gas path, and control in pressure swing adsorption (PSA) nitrogen
should be atmospheric conditions)
built-in solenoid valve protects the gas path,and has unlim- Analyzer size: L×W×H=244mm×258.5mm×147.5mm and the seal is reliable,and the state of the gas path can be making equipment;chemical process;
ited opening times and long service life.The microproces- automatically controlled by the microprocessor. Protective gas in high temperature sintering furnace such as
sor controls the purge or test status of the gas path. magnetic material;
・The new structure of the test chamber can satisfy the field
・Personalized test chamber:Fuel cell oxygen sensor itself The interference effects of various gases on measurement: Protective gases in the electronic industry;
replacement of the sensor.
determines that it must be replaced after reaching its Gas Concentration Interference Glass,building materials industry,etc.
service life.The test chamber used in this analysis is a new
H2S <5ppm No interference Technical Specifications
structure design,which can not only meet the needs of
SO3 <10ppm No interference Measure range: 0~10/100/1000ppm/1%/25% O2
sensor replacement without any tools on site,but also need Order Information
SO2 <10ppm No interference Accuracy: 0.01~9.99ppm O2:±5% FS
not use standard gas calibration. ・ Pneumatic connection mode:A,Φ6 hose (standard);B,
HCL <1000ppm No interference 10.0~99.9ppm O2:±3% FS
・Menu lock switch:to prevent misoperation to change the connecting by using 1/4-Φ6 stainless steel cutting ferrule;
HCN <1000ppm No interference 100~1000ppm O2:±2% FS
parameters of the analyzer,affecting its normal operation; C,connecting by using 1/8 -Φ3 stainless steel cutting ferrule;
CO2 No interference Repeatability: 0.01~9.99ppm O2:±2.5% FS
・Self-set analog output:isolated analog signal output, <1000ppm
10.0~99.9ppm O2:±1.5% FS ・ Filter:GF2800, AF2000;
4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V analog output mode NO2 <1000ppm 1ppm→2ppmO2
100~1000ppm O2:±1% FS ・ Pressure of the measured gas:positive pressure,micro
can be set freely through the menu. CL2 <1000ppm 1ppm→2ppmO2
Stability: 0.01~9.99ppm O2:±2.5% FS/7d pressure or negative pressure;
10.0~99.9ppm O2:±1.5% FS/7d ・ Sample gas should not contain the following substances:
100~1000ppm O2:±1% FS/7d 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
Sensitivity: 0.5% in full range 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
Technical Specifications Response time: T90<60s(25°C) 3.Fluxes such as rosin;
Instructions Recovery time: 60 minutes, from air (20.94%) to 10 ppm
Measure range: 0~10/100/1000ppm/1%/25.00% O2 4.Reductive components and hydrocarbons,such as ethanol;
Accuracy: 0.01~9.99ppm O2:±5% FS ・Sensor principle:please refer to page 2 of this sample Sensor: Fuel cell oxygen sensor 5.Impurities,such as dust.
10.0~99.9ppm O2:±3% FS book; Calibration cycle: one year (recommended)
100~1000ppm O2:±2% FS ・Application and Ordering Notes:Please refer to page 16 Relay contact point
capacity: 24VDC,0.2A
Repeatability: 0.01~9.99ppm O2:±2.5% FS of this sample. Instructions
10.0~99.9ppm O2:±1.5% FS Power supply: 200~240VAC,50/60Hz
100~1000ppm O2:±1% FS Communication: RS485(standard)/RS232(optional) ・Sensor principle:please refer to page 2 of this sample book;
Environment Interference effects of various gases on measurement:
Stability: 0.01~9.99ppm O2:±2.5% FS/7d
10.0~99.9ppm O2:±1.5% FS/7d Temperature: 0~45°C Environment Humidity:<80%RH ・please refer to page 15 of this sample book.
100~1000ppm O2:±1% FS/7d Sample temperature: 0~45°C

15 16
Portable trace oxygen analyzer Portable trace oxygen analyzer

CI-PC931/932 GNL-2100
Portable trace oxygen Portable oxygen/nitrogen
analyzer analyzer
CI-PC931/932 analyzer is suitable for the measure- GNL-2100 portable oxygen/nitrogen analyzer uses ion
ment of trace oxygen in various industrial and outdoor flow sensor as measurement unit and combines micropro-
environments,and provides the display of oxygen concen- cessor with digital processing technology.The analyzer is
tration.It takes microcontroller technology as its core and suitable for measuring oxygen/nitrogen concentration in
fuel cell oxygen sensor as its measuring unit.It has the various industrial and outdoor environments.
characteristics of intelligence,high precision,fast response The analyzer USES lithium battery with large capacity
and good stability.The large capacity lithium battery used and long standby time. The 128*64 LCD screen is used as the
in the analyzer has a long standby time. window, which is intuitive and rich in content.Users can set
various parameters freely,and the operation is simple.

Product Features Technical Specifications Product Features Applications


・It has the characteristics of intelligence,good stability,high Environment ・With microprocessor as the core,it has the characteris- ・ Air separation;
reliability and long calibration cycle. temperature: 0~45°C Environment Humidity:<80%RH tics of intelligence,good stability,high precision and ・ Detection of oxygen concentration of protective gas in
・Digital temperature compensation function:it adopts the Sample gas long calibration cycle. welding furnace;
most advanced temperature compensation method in the pressure: atmospheric conditions±10% (Gas outlet ・Long standby time:built-in large-capacity lithium battery,- ・ Detection of oxygen concentration in gas production;
world,and its temperature compensation effect is world should be atmospheric conditions) standby time is no less than 8 hours in normal use; ・ Detection of oxygen concentration in protective gases in
leading. Analyzer weight: CI-PC931:Net weight 5.0 kg ・Menu lock switch:prevent misoperation to change the semiconductor industry;
・Over-voltage protection function:when the internal pressure CI-PC932:Net weight 6.45 kg analyzer parameters,affecting its normal operation; ・ Detection of oxygen concentration in protective gas in
of the gas circuit exceeds the protection range, the gas ・Alarm function:if the oxygen/nitrogen concentration reflow/wave soldering;
Analyzer size: CI-PC931:
circuit will be cut off automatically to avoid the damage of deviates from the set alarm value,the analyzer will send ・ Detection of oxygen concentration of gases in vegetable
L×W×H=305mm×270mm×144mm
the sensor due to too large or too small pressure; and food processing and storage;
CI-PC932: an alarm and output the switch signal.The alarm value
・Pressure compensation function:reduce the influence of ・ Detection of oxygen concentration in gases in petrochem-
L×W×H=360mm×304mm×194mm can be set freely within the full range.
pressure on the oxygen concentration in sensor test,mak- ical process;
ing the measurement more accurate.
・ Detection of oxygen concentration in inert gas,etc.
・Over range protection function:concentration protection
function,when the oxygen concentration exceeds the Applications Order Information
protective concentration,the gas path will be cut off Technical Specifications
automatically,so as to avoid the influence of the sensor's
・ Air separation; ・ Pressure of the measured gas:positive pressure,micro
・ Gas production and testing; Sensor: Ion flow oxygen sensor pressure or negative pressure;
performance and life in the environment with high oxygen
・ Protection gas detection in semiconductor industry; Accuracy: 99.99%~99.999% N2:±10%FS ・ The main components of the measured gas:whether it
concentration for a long time.
・The new structure of the test chamber and the use of digital ・ Protection gas detection in reflow/wave soldering; 98%~99.999% N2:±2%FS contains corrosive gases (such asF,HF,Cl2,HCl etc.),tox-
sensors can not only be replaced on site,but also need no ・ Gas detection in food production process; 79%~99.999% N2:±1.5%FS ic substances (such as Si,Pb,P etc.)
calibration. ・ Gas detection in petrochemical process; Repeatability: 99.99%~99.999% N2:±5%FS Model Test range
・ Detection of oxygen concentration in inert gas and hydro- 98%~99.999% N2:±1%FS
GNL-2100-3O 1000ppm~21.0% O2
Technical Specifications carbon gas,etc. 79%~99.999% N2:±0.75%FS
Stability: 99.99%~99.999% N2:±5%FS/7d GNL-2100-4O 100ppm~21.00% O2
Measure range: 0~10/100/1000ppm/1%/25% O2
98%~99.999% N2:±1%FS/7d GNL-2100-5O 10ppm~21.000% O2
Sensor: Fuel cell oxygen sensor
Accuracy: 0.01~9.99ppm O2:±5% FS Order Information 79%~99.999% N2:±0.75%FS/7d
GNL-2100-3N 79.0%~99.9% N2
10.0~99.9ppm O2:±3% FS Response
・Whether equipped with pump and needle valve; GNL-2100-4N 79.00%~99.99% N2
100~1000ppm O2:±2% FS time: T90<20s(after full preheating)
・The difference between CI-PC931 and CI-PC932:
Repeatability: 0.01~9.99ppm O2:±2.5% FS Measuring GNL-2100-5N 79.000%~99.999% N2
CI-PC932 is equipped with patented high-performance
10.0~99.9ppm O2:±1.5% FS medium: air or inert gas
activated carbon filters. Sensor type corresponding to the analyzer:
100~1000ppm O2:±1% FS Power supply: 85~264VAC,50/60Hz
Stability: 0.01~9.99ppm O2:±2.5% FS/7d ・Main components of the measured gas:whether it
Switch output: 1 set GNL-2100-3O/3N OLZL04
10.0~99.9ppm O2:±1.5% FS/7d contains CO2,H2S,SO2,NOx,NH3 and other gases
Relay contact point capacity:24V DC,0.2A GNL-2100-4O/4N OLZL03
100~1000ppm O2:±1% FS/7d Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/
Response time: T90<60s(25°C) Instructions 1-5V (You can set the mode freely).
GNL-2100-5O/5N OLZL02
Power supply: 220VAC±10%,50/60Hz
・Sensor principle:please refer to page 2 of this sample Communication: RS485(standard)/RS232(optional)
Communication:RS485(standard)/RS232(optional)
book; Environment
Instructions
Signal output: 2 sets,Relay contact point capacity:24V
DC,0.2A ・Interference effects of various gases on measurement: temperature: -10~45°C,Environment Humidity:<80%RH Principle:please refer to page 46 of this sample book;
Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ please refer to page 15 of this sample book.
1-5V (You can set the mode freely).

17 18
Portable trace oxygen analyzer Portable trace oxygen analyzer

CI-PC832 CI-PC13
Portable oxygen/nitrogen Portable trace oxygen
analyzer analyzer
CI-PC13

CI-PC832 portable oxygen/nitrogen analyzer uses 3D ion CI-PC13 analyzer is based on microcontroller technolo-
current sensor as measuring unit,combines microprocessor gy as the core,using frequency conversion ion flow oxygen
with digital processing technology,and has the characteristics sensor as the measurement unit of oxygen concentration
of intelligence,high precision,fast response and good stability. detection equipment.It adopts digital processing technolo-
The analyzer is suitable for measuring oxygen concentration gy,including zero range calibration,linearization processing,
in various industrial and outdoor environments. switch output control,current/voltage output,parameter setting
The analyzer has the functions of alarm output, commu- and other functions,all using digital processing technolo-
nication,analog signal output and so on.The 4.3-inch color gy.The analyzer has the functions of alarm output,communi-
touch screen is used as the display window and input device cation,external control and analog signal output.
of human-computer interaction,which is rich in content,intui-
tive and convenient to operate.
Product Features Technical Specifications Product Features Technical Specifications
・With microprocessor as the core and 3D ion current sensor Exhaust port and ・With microprocessor as the core and frequency conver- temperature: -10~45°C Environment Humidity:<80%RH
as the measuring unit,it has the characteristics of intelligence, discharge port: Φ6 stainless steel pipe sion ion flow oxygen sensor as the measuring unit, it has Sample gas
good stability,high accuracy and long calibration cycle. the characteristics of intelligence,good stability,high accura- pressure: atmospheric conditions±10% (Gas outlet
・The display frame of the analyzer is covered with a piece Type and measurement range: cy and long calibration cycle. should be atmospheric conditions)
of toughened glass,which is not only beautiful,but also has Weight: 4.5kg net,5.5kg after packaging
Display mode Model Test scope ・Pressure detection function:test the relative pressure inside
a good protective effect on touch screen. Packing case
the gas path,judge whether the gas path is blocked, when
・Built-in large capacity lithium battery,standby time is more Display of CI-PC832-3O 0.1%~21.0% O2 size: carton L×W×H=470×410×315mm
than 3.5 hours in normal use; the sample pressure exceeds the set range,it will give an
oxygen(O2) CI-PC832-4O 100ppm~21.00% O2
・Pressure compensation function:the analyzer has the func- alarm;
concentration
tion of pressure compensation to reduce the influence of CI-PC832-5O 10ppm~21.000% O2 ・Menu lock switch:prevent misoperation and change of
pressure on the accuracy of oxygen concentration measure- analyzer parameters from affecting its normal operation;
ment,so that the measurement accuracy is higher. Display of
CI-PC832-3N 79.0%~99.9% N2
・Alarm function:When the oxygen concentration deviates Applications
・Convenient data storage function:the analyzer has the nitrogen(N2) CI-PC832-4N 79.00%~99.99% N2 from the alarm value,the alarm value can be set arbitrarily ・ Air separation;
function of timing automatic storage of test data,which is concentration within the full range. ・ Detection of oxygen concentration of protective gas in
CI-PC832-5N 79.000%~99.999% N2
convenient to understand the test situation. welding furnace;
Technical Specifications ・ Detection of oxygen concentration in gas production;
Applications
・ Detection of oxygen concentration in protective gases
Measure range: 0~25.00% O2
Technical Specifications ・ Air separation industry,such as pressure swing adsorp- in semiconductor industry;
tion (PSA) oxygen/nitrogen production; Sensor: frequency conversion ion flow oxygen senso
Sensor: 3D Ion flow oxygen sensor Accuracy: 0.01~99.9 ppm:±5ppm
・ Detection of oxygen concentration in protective gas in
Accuracy: ±1% FS ・ Chemical and smelting industries; reflow/wave soldering;
100~999.9ppm:±3%FS
Repeatability: ±0.5% FS ・ Detection of oxygen concentration in inert gases; ・ Detection of oxygen concentration of gases in vegeta-
1000~9999 ppm:±3%FS
Stability: ±0.5% FS/7d ・ Detection of oxygen/nitrogen concentration in gas convey- ble and food processing and storage;
1.00%~25.00%:±3% of the measured value
Response time: T90<20s(after full preheating) ing to high temperature furnace; ・ Detection of oxygen concentration in gases in petro-
Repeatability: 0.01~99.9 ppm:±2.5ppm
Measuring ・ Detection of oxygen/nitrogen concentration in the process 100~999.9ppm:±1.5%FS chemical process;
medium: air or inert gas of vegetable and food processing and storage; 1000~9999 ppm:±1.5%FS ・ Detection of oxygen concentration in inert gas,etc.
Display resolution:0.01% ・ Detection of oxygen/nitrogen concentration in family,naval 1.00%~25.00%:±1.5% of the measured value
Measurement: Portable vessel,underground command center,tunnel,deep well,civil Stability: 0.01~99.9 ppm:±2.5ppm/7d
Calibration cycle: one year (recommended) air defense engineering,urban tunnel,etc. 100~999.9ppm:±1.5%FS/7d Order Information
Display: 4.3-inch color touch screen
Power supply: 85~264VAC,50/60Hz 1000~9999 ppm:±1.5%FS/7d ・ Pneumatic connection mode:A,Φ6 hose (standard);B,
Power consumption 1.00%~25.00%:±1.5% of the measured value/7d connecting by using 1/4-Φ6 stainless steel cutting
of analyzer: less than 25VA Order Information Response time: T90<20s (after full preheating) ferrule;C,connecting by using 1/8 -Φ3 stainless steel
Standby time: more than 3.5 hours during normal test Power supply: 85~264VAC,50/60Hz
・ Pressure of the measured gas:positive pressure,micro cutting ferrule;
Sensor life: more than 2 years (normal use) Power
pressure or negative pressure; ・ Pressure of the measured gas:positive pressure,micro
Instrument life: more than 5 years (normal use) consumption of
・ The main components of the measured gas:whether it pressure or negative pressure;
Environment analyzer: less than 25VA
contains corrosive gases(such as HF,Cl2,HCl,SO2,H2S ・ Sample gas should not contain the following substanc-
temperature: -10~45°C,Environment Humidity:<80%RH Communication:RS232(standard)/RS485(optional)
Weight: 3kg±0.5kg (slightly different etc.),toxic substances(such as Si,Pb,P,Zn,Sn,As etc.). Signal output: 22 sets, Relay contact point capacity:24V es:
depending on configuration) DC,0.2A 1.Corrosive gases,such as HF,Cl2,HCl etc.
Sample gas Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V 2.Toxic substances,such as Si,Pb,P etc.
pressure: atmospheric conditions±10%(Gas outlet (You can set the mode freely). 3.Fluxes;
should be atmospheric conditions) Instructions The load: less than 500 Ω 4.Reductive components and hydrocarbons;
Inlet air flow: 2~5L/min Principle:please refer to page 46 of this sample book; External control:1 set Control signal:9-28VDC 5.Impurities,such as dust.
Inlet: 1/4-Φ6 hose connector Standard(replaceable) Environment

19 20
Constant oxygen analyzer Constant oxygen analyzer

CI-PC962 CI-PC912
Electrochemical oxygen Electrochemical oxygen
analyzer analyzer
CI-PC962 analyzer is an intelligent oxygen analyzer CI-PC912 analyzer uses electrochemical gas sensor
with microprocessor as its core and CI-25 electrochemi- as measuring unit and combines microcontroller with
cal gas sensor as its measuring unit.It has the character- digital processing technology.It has complete self-diag-
istics of intelligence,high precision and long service life.It nosis function and it can monitor the working state of the
is suitable for accurate measurement of oxygen concen- instrument at any time.The analyzer has the advantages
tration in various industries and environments. of intelligence,stability,reliability and long service life.It is
suitable for accurate measurement of oxygen concentra-
tion in mixed gases in various industries and environ-
ments.

Product Features Technical Specifications Product Features Technical Specifications


・With microprocessor as the core,it has the characteristics signal: A set of 9-28VDC signals can be ・With microprocessor as the core and electrochemical gas The load: less than 500Ω
of intelligence,good stability and long calibration cycle. connected to control pumps (optional) sensor as the measuring unit,it has the characteristics of Communication: RS485(standard)/RS232(optional)
・The electrochemical sensor is used as the measuring unit Communication: RS485(standard)/RS232(optional) intelligence,stability,high precision and long calibration Switching signal: 6 sets
with high accuracy,long service life and stable signal Signal output: 2 sets cycle. Relay contact point capacity:24V DC,0.2A
output. Relay contact ・Menu lock switch:prevent misoperation and change of External control:quantity:5 sets
・Sensors need no external power supply and heating. point capacity: 24VDC,0.2A analyzer parameters from affecting its normal operation; Control signal:9~28VDC
・The sensor is not affected by CO2,CO,H2S,NO2 and H2. Instrument size: 144mm(W)×144mm(H)×251mm(D) ・Convenient data storage function:The analyzer has the
・Menu lock switch:prevent misoperation from affecting Instrument installation function of storing test data automatically on time,and Applications
analyzer; dimensions: 136mm×136mm supports U disk and SD card,which has a large amount of
Instrument weight:self-weight 3 kg,packing about 4.5 kg data storage. ・ Air separation industry, such as pressure swing adsorp-
・2-way alarm output:when the oxygen concentration deviates tion (PSA) oxygen production;
Packing box size:(L×W×H=400mm×295mm×285mm) ・Alarm function:When the oxygen concentration deviates
from the alarm value or when the operation is wrong,the
Single point from the alarm value,the alarm value can be set arbitrarily ・ Detection of oxygen concentration in gas production;
alarm value can be set freely within the full range. ・ Detection of oxygen concentration in protective gases
calibration: The electrochemical sensor outputs a within the full range.
・RS485/RS232 (optional) two-way communication function,- in semiconductor industry;
voltage signal corresponding to the oxygen ・Communication function:RS485 (standard)/RS232 (option-
can communicate directly with computers or other digital ・ Detection of oxygen concentration in oxygen making
concentration in the sample gas.Accord- al) two-way communication,which can communicate direct-
communication equipment; ing to the linearity of the voltage signal,s- ly with computer or other digital communication equipment. equipment;
・A set of isolated analog signal outputs.The analog output ingle point calibration can achieve accurate ・ Detection of oxygen concentration of gases in vegeta-
mode of 4-20mA/0-20mA/0-10V can be set freely by menu. measurement. ble and food processing and storage;
・The model has the advantages of simple structure, conve- ・ Detection of oxygen concentration in gases in petro-
Technical Specifications
nient operation and maintenance. chemical process;
Principle Sensor principle: Electrochemical Sensor ・ Detection of oxygen concentration in inert gas and
Measure range: 0~25.00% O2 hydrocarbon gas,etc.
Electrochemical element Accuracy: ±2%FS

Technical Specifications
On the surface of the gold electrode,O2 Repeatability: ±1%FS Order Information
reduces H2O to gain electrons Stability: ±1%FS/7d
-
O2+4H++4e =2H2O Response time: T90<20s ・ Pneumatic connection mode:A,Φ6 hose (standard);B,
Measure range: 0~25.00% O2
Accuracy: ±2% FS Lead in the anode is oxidized to lead Power supply: 85~264VAC,50/60Hz connecting by using 1/4-Φ6 stainless steel cutting
Repeatability: ±1% FS oxide to release electrons Power consumption ferrule;C,connecting by using 1/8 -Φ3 stainless steel
Stability: ±1% FS/7d 2Pb+2H2O=2PbO+4H++4e
- of analyzer: <35VA cutting ferrule;
Response time: T90<20s The total reaction formula is: Environment ・ Sample gas should not contain the following substanc-
Sensor principle: Electrochemical Sensor O2+2Pb=2PbO temperature: -10~+45°C es:
Power supply: 85~264VAC,50/60Hz The lead oxide produced by using an Environment 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
Environment acid electrolyte(acetic acid)is soluble,so humidity: <90%RH 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
temperature: 0~45°C Environment Humidity:<90%RH Sample gas 3.Fluxes such as rosin;
the anode is renewable.
Sample gas + pressure: atmospheric conditions±10% (Gas outlet 4.Reductive components and hydrocarbons,such as

pressure: atmospheric conditions±10% (Gas outlet should be atmospheric conditions) ethanol;
should be atmospheric conditions) Sample gas flow
Sample gas flow rate: 500~1000ml/min
rate: 500~1000ml/min Instructions Sensor life: more than 2 years (normal use)
Instructions
Storage Instrument life: more than 5 years (normal use)
Application and Ordering Notes:Please refer to page 22 of
temperature: -5~+50°C Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ Principle:Please refer to page 21 of this sample book
this sample book.
External control 1-5V,(You can set the mode freely).

21 22
Constant oxygen analyzer Constant oxygen analyzer

CI-PC933 CI-PC162
Portable trace oxygen Frequency conversion
analyzer ion flow oxygen analyzer
CI-PC933 analyzer is based on microcontroller technol- CI-PC162 analyzer is an intelligent oxygen analyzer
ogy as the core,using electrochemical gas sensor as the with microprocessor as its core and frequency conver-
measurement unit of oxygen concentration detection sion ion flow oxygen sensor as its measuring unit.It has
equipment.It adopts digital processing technology,includ- the characteristics of intelligence and high precision.It is
ing zero/range calibration,linearization processing,switch suitable for accurate measurement of 0-25.00% oxygen
output control,current/voltage output,parameter setting concentration in nitrogen-oxygen mixture in various indus-
and other functions,all using digital processing technolo- tries and environments.
gy.The analyzer has the functions of alarm output,com-
munication,external control and analog signal output.

Product Features Technical Specifications Product Features Technical Specifications


・With microprocessor as the core and electrochemical gas External control: Number:1 group;Control signal:9-28VDC ・It has the characteristics of intelligence,good stability, Sample gas
sensor as the measuring unit,it has the characteristics of Environment high accuracy and long calibration cycle. pressure: atmospheric conditions±10% (Gas outlet
intelligence,good stability,high accuracy and long calibra- temperature: -10~45°C ・Oxygen concentration,various data and the working should be atmospheric conditions)
tion cycle. Environment state of the instrument are displayed by 128*64 LCD Sample gas
・Oxygen concentration,various data and the working state humidity: <80%RH window.The display is intuitive and is easy to operate. flow rate: 400~600ml/min
of the instrument are displayed by 128*64 LCD window.The Sample gas ・The surface of the window is covered with a piece of Sensor life: more than 2 years (normal use)
display is intuitive and the content is rich. flow rate: 500~1000ml/min toughened glass,which protects the LCD screen and
・Using the latest touch button technology,it is easy to operate Instrument life:more than 5 years (normal use)
Sample gas keys by using the latest touch key technology and Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V
and has a long service life.
pressure: conditions±10%(Gas outlet should be prolongs the service life of keys. /1-5V,(You can set the mode freely).
・Built-in large-capacity lithium battery,long standby time; ・Menu lock switch:prevent misoperation and change of
atmospheric conditions)
・Menu lock switch:prevent misoperation and change of analyz- Communication:RS232(standard)/RS485(optional)
Inlet and outlet: 1/4-inch NPT internal thread,stainless steel analyzer parameters from affecting its normal opera-
er parameters from affecting its normal operation; Relay contact
Weight: 4.25kg net,5.25kg after packaging tion;
・Convenient data storage function:The analyzer has the point capacity: 24VDC,0.2A
functions of automatic storage and manual storage of test Packing case size: L×W×H=470mm×410mm×315mm ・Data storage function:recording test data regularly and
data,and supports U disk and SD card,which has a large querying and storing data quickly;
amount of data storage. ・Alarm function:When the oxygen concentration deviates Applications
・Alarm function:When the oxygen concentration deviates Applications from the alarm value,the alarm value can be set arbitrari-
from the alarm value,the alarm value can be set arbitrarily ly in the full range. ・ Air separation;
in the full range. It is widely used in air separation industry,such as pressure ・ Gas production and testing;
swing adsorption (PSA) nitrogen production; ・ Protection gas detection in semiconductor industry;
・Communication function:RS232 (standard) and RS485 Technical Specifications
(optional) two-way communication can be used to commu- Measurement and control of oxygen concentration in ・ Protection gas detection in reflow/wave soldering;
nicate directly with computers or other digital communica- oxygen making equipment; Sensor: Frequency conversion ion flow oxygen sensor ・ Gas detection in food production process;
tion equipment. Petrochemical industry and smelting industry,such as the Measure range: 0~25.00% O2 ・ Gas detection in petrochemical process;
detection of oxygen concentration in semi-conductor shield- Accuracy: 0.01~99.9 ppm ±5ppm ・ Detection of oxygen concentration in inert gas,etc.
Technical Specifications ing gas; 100~999.9ppm ±3%FS
Determination of oxygen concentration in processing and 1000~9999 ppm ±3%FS
Measure range: 0~25.00% O2 storage of vegetables and food. 1.00%~25.00% ±3% of the measured value Order Information
Sensor: electrochemical gas sensor Repeatability: 0.01~99.9 ppm ±2.5ppm
Accuracy: ±2%FS ・Pneumatic connection mode:A,Φ6 hose (standard);B,
Order Information 100~999.9ppm ±1.5%FS
Repeatability: ±1%FS connecting by using 1/4-Φ6 stainless steel cutting
1000~9999 ppm ±1.5%FS
Stability: ±1%FS/7d ・ Pneumatic connection mode:A,Φ6 hose (standard); ferrule;C,connecting by using 1/8-Φ3 stainless steel
1.00%~25.00% ±1.5% of the measured value
Response time: T90<20s B,connecting by using 1/4-Φ6 stainless steel cutting cutting ferrule;
Stability: 0.01~99.9 ppm ±2.5ppm/7d
Display: 128×64 LCD ferrule;C,connecting by using 1/8 -Φ3 stainless steel ・Filter:GF2800,AF2000;
100~999.9ppm ±1.5%FS/7d
Power supply: 85~264VAC,50/60Hz cutting ferrule; ・Pressure of the measured gas:positive pressure,micro
1000~9999 ppm ±1.5%FS/7d
Power consumption ・ Pressure of the measured gas:positive pressure,micro pressure or negative pressure;
of analyzer: less than 20VA 1.00%~25.00% ±1.5% of the measured
pressure or negative pressure; ・Sample gas should not contain the following substanc-
Communication:RS485(standard)/RS232(optional) value/7d
・ Whether to configure pumps and needle valves es:
Signal output: Alarm output:2 sets of switching signals(1 set Response time:T90<20s (after full preheating)
1.Corrosive gases,such as HF,Cl2,HCl,etc.
of state alarm,1 set of concentration alarm) Power supply: 85~264VAC,50/60Hz
2.Toxic substances,such as Si,Pb,P,etc.
Relay contact point capacity:24V DC,0.2A Environment
3.Fluxes;
Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ Instructions temperature: -10~50°C
4.Reductive components and hydrocarbons,such as ethanol;
1-5V,(You can set the mode freely). Principle:Please refer to page 21 of this sample book Environment
5.Impurities,such as dust.
The load:less than 500 Ω humidity: <80%RH

23 24
Constant oxygen analyzer Constant oxygen analyzer

CI-PC11 CI-PC951/-1
Frequency conversion Explosion-proof oxygen
ion flow oxygen analyzer analyzer
CI-PC11 oxygen analyzer uses frequency conversion The case of CI-PC951 /-1 explosion-proof micro oxygen
ion current sensor as measuring unit and combines micro- analyzer is designed with flameproof design.The flameproof
controller with digital processing technology.It has complete sign of Ex element is Exd II C,which is the whole flameproof
structure.It can be used in dangerous environment of zone 1
self-diagnosis function and monitors the working state of
and zone 2 formed by explosive gases and their mixtures
the instrument at any time.The analyzer has the advan- containing class II C T6 and below.The analyzer can measure
tages of intelligence,stability,reliability and long service oxygen content accurately in various environments.The instru-
life.It is suitable for accurate measurement of oxygen ment is a new generation of micro oxygen analyzer based on CI-PC951-1
concentration in mixed gases in various industries and electrochemical sensors.The functions of calibration,linear-
ization,switching output control,current/voltage output and
environments.
parameter setting are all based on digital processing technol-
CI-PC951
ogy.
Product Features Technical Specifications Product Features Technical Specifications
・With microprocessor as the core and frequency conversion Communication: RS485(standard)/RS232(optional) ・With microprocessor as the core, it has good long-term Sample gas
ion current sensor as measurement unit,it has the charac- Signal output: Alarm output:6 sets of switching signals stability and high reliability. pressure: atmospheric conditions±10%(Gas outlet
teristics of intelligence,stability,high precision and long calibra- Relay contact point capacity:24V DC,0.2A ・The electrochemical sensor is used as the measuring unit should be atmospheric conditions)
tion cycle. External control: Number:5 sets; with high accuracy and long calibration period. Inlet and outlet:1/4-inch NPT internal thread,stainless steel
・Menu lock switch:prevent misoperation and change of analyz- Control signal:9-28VDC ・Using the latest touch button technology,it is easy to material (standard 1/4-6 card-plastic joint)
er parameters from affecting its normal operation; Instrument size: L×W×H=483mm×300mm×177mm operate and has a long service life.
・Alarm function:When the oxygen concentration deviates ・Menu lock switch:prevent misoperation and change of
Sensor life: more than 2 years (normal use)
from the alarm value,the alarm value can be set arbitrarily analyzer parameters from affecting its normal operation;
・Data Storage:Support the use of U disk and SD card to Instrument life: more than 5 years (normal use)
in the full range.
・Communication function:RS485(standard) and RS232(option- Applications store data,the data storage is large and easy for users to CI-PC951: L×W×H=300×200×175mm
process and analyze data;The internal timing data storage Flow meter:Selection
al) two-way communication. ・ Air separation industry,such as pressure swing adsorp- of the instrument facilitates users to view the test data CI-PC951-1: L×W×H=375×315×179mm
・The isolated analog signal output can be freely set to tion (PSA) oxygen production;
4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V by menu.
quickly. Level of explosion-proof:Exd || CT6 (certifi-
・ Detection of oxygen concentration in gas production; ・Alarm function:When the oxygen concentration deviates cation)
・ Detection of oxygen concentration in protective gases from the alarm value,the alarm value can be set arbitrarily
in semiconductor industry; in the full range.
Technical Specifications ・ Detection of oxygen concentration of gases in vegeta-
Applications
ble and food processing and storage;
Sensor: frequency conversion ion current sensor
・ Detection of oxygen concentration in gases in petro- ・ Air separation;
Measure range: 0~25.00% O2
chemical process; Technical Specifications ・ Gas production and testing;
Accuracy: 0.01~99.9 ppm ±5ppm
・ Detection of oxygen concentration in inert gas and hydro- Sensor: electrochemical gas sensor ・ Protection gas detection in reflow/wave soldering;
100~999.9ppm ±3%FS
carbon gas,etc. Measure range: 0~25.00% O2 ・ Gas detection in food production process;
1000~9999 ppm ±3%FS
・ Synthetic ammonia production,vacuum injection,ad- Accuracy: ±2%FS ・ Gas detection in petrochemical process;
1.00%~25.00% ±3% of the measured value
vanced plastic production. ・ Detection of oxygen concentration in inert gas and
Repeatability: 0.01~99.9 ppm ±2.5ppm Repeatability: ±1%FS
100~999.9ppm ±1.5%FS Stability: ±1%FS/7d hydrocarbon gas,etc.
1000~9999 ppm ±1.5%FS Response time: T90<20s
1.00%~25.00% ±1.5% of the measured value Order Information Protection level: IP64 Order Information
Stability: 0.01~99.9 ppm ±2.5ppm/7d Measuring method:on-line
・ Pneumatic connection mode:A,Φ6 hose (standard);B, ・ Pneumatic connection mode:A,Φ6 hose (standard);B,
100~999.9ppm ±1.5%FS/7d Calibration cycle: one year (recommended)
connecting by using 1/4-Φ6 stainless steel cutting connecting by using 1/4-Φ6 stainless steel cutting
1000~9999 ppm ±1.5%FS/7d Power supply: 24V DC
ferrule;C,connecting by using 1/8-Φ3 stainless steel ferrule;C,connecting by using 1/8-Φ3 stainless steel
1.00%~25.00% ±1.5% of the measured Analyzer power
cutting ferrule;
value/7d consumption: <15VA cutting ferrule;
・ Pressure of the measured gas:positive pressure,micro
Response time:T90<20s(after full preheating) Communication: RS485(standard)/RS232(optional) ・ Filter:GF2800,AF2000;
pressure or negative pressure;
Power supply: 85~264VAC,50/60Hz Switch output: Alarm output:1 set of switching signal ・ Pressure of the measured gas:positive pressure,micro
・ Sample gas should not contain the following substances:
Environment Relay contact point capacity:24VDC,0.2A pressure or negative pressure;
1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
temperature: -10~+45°C Environment Humidity:<90%RH Environment
2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
Sample gas
3.Fluxes such as rosin; emperature: -10~45°C Environment Humidity:<90%RH
pressure: atmospheric conditions±10%(Gas outlet
Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V
Instructions
4.Reductive components,such as ethanol;
should be atmospheric conditions)
/1-5V,(You can set the mode freely). Principle:Please refer to page 21 of this sample book
Analog output: 2set,4-20mA/0-20mA/0-1V/0-5V/0-10V/
The load:less than 500 Ω
1-5V(You can set the mode freely).
The load: less than 500 Ω Sample flow rate:500~1000ml/min

25 26
Constant oxygen analyzer Constant oxygen analyzer

CI-PC951-2 CI-PC85/-1
Explosion-proof oxygen Explosion-proof oxygen/
analyzer nitrogen analyzer
The case of CI-PC951-2explosion-proof micro oxygen The case of CI-PC85/-1 oxygen/nitrogen analyzer is designed
analyzer is designed with flameproof design.The flameproof with explosion-proof design.The explosion-proof sign of Ex element
sign of Ex element is Exd II CT6,which is the whole flame- is Exd II C,which is the whole flameproof structure.It can be used in
proof structure.Because of its flameproof and explosion-proof dangerous environment of zone 1 and zone 2 formed by explosive
structure,the analyzer can also be used in dangerous environ- gases and their mixtures of Class II C T6 and below.The instrument
ments containing explosive gases and their mixtures of is a new generation of intelligent oxygen/nitrogen analyzer based on
Class II C T6 and below in addition to meeting the general ion flow sensor.After amplifying,filtering and linearizing the sensor
non-explosion-proof requirements.The analyzer uses electro- signal,the analyzer calculates the oxygen concentration in the CI-PC85-1
nitrogen-oxygen mixture by microprocessor,and provides the
chemical sensors as measuring units, which can measure
oxygen concentration display,or calculates the nitrogen concentra-
oxygen concentration accurately in various environments and
tion in the nitrogen-oxygen mixture according to the oxygen concen-
provide users with oxygen concentration display. tration value,and provides the nitrogen concentration display. CI-PC85

Product Features Technical Specifications Product Features Technical Specifications


・It combines microcontroller with digital processing Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ ・ The analyzer uses a new long-life ion flow oxygen sensor 0-10V/1-5V,(You can set the mode freely).
technology to resist cross-interference and is stable 1-5V(You can set the mode freely). with high accuracy and fast response. The load:less than 500 Ω
and reliable. The load:less than 500 Ω ・ High precision automatic temperature compensation Inlet and outlet:1/4-inch NPT(standard 6.5 stainless steel joint)
・The electrochemical sensor has high precision and Switch output: Alarm output:1 set system can reduce the influence of ambient tempera- CI-PC85: L×W×H=300×200×175mm
good stability. Relay contact point capacity:24V DC,0.2A ture on measuring accuracy. Flow meter:Selection
・With the latest touch key technology,it is easy to Environment ・ Menu lock switch:prevent misoperation and change of CI-PC85-1: L×W×H=375×315×179mm
operate and has a long service life. temperature: -10~+45°C analyzer parameters from affecting its normal opera- Level of explosion-proof:Exd || CT6
・With infrared remote-control function,the analyzer can Environment tion; (certification)
be operated by remote control. humidity: <90%RH ・ Data Storage:Support the use of U disk and SD card to
・Menu lock switch:prevent misoperation and change of Sample flow rate: 500~1000ml/min store data,the data storage is large and easy for users
analyzer parameters from affecting its normal opera- Sample gas Display mode Model Test scope
to process and analyze data;The internal timing data
tion; pressure: atmospheric conditions±10% (Gas outlet
storage of the instrument facilitates users to view the Display CI-PC85/-1-3O 1000ppm~21.0% O2
・The explosion-proof design is adopted,and the explo- should be atmospheric conditions)
test data quickly. of oxygen CI-PC85/-1-4O 100ppm~21.00% O2
sion-proof grade reaches Ex II CT6. Gas interface: 1/4-inch NPT internal thread,standard 6.5 (O2)concen
・Alarm function:When the oxygen concentration deviates hose joint tration CI-PC85/-1-5O 10ppm~21.000% O2
from the alarm value,the alarm value can be set freely Sensor life: more than 2 years (normal use) Technical Specifications Display of CI-PC85/-1-3N 79.0%~99.9% N2
in the full range. Instrument life: more than 5 years (normal use) nitrogen
Sensor: Ion flow oxygen sensor (N2)concen CI-PC85/-1-4N 79.00%~99.99% N2
・Communication function:RS485/RS232; Weight: 2.35kg net
Accuracy: 99.99%~99.999% N2:±10%FS tration CI-PC85/-1-5N 79.000%~99.999% N2
・Only one of the analog signals,RS485 and RS232 can Installation: wall-mounted
98%~99.999% N2:±2%FS
be selected. 79%~99.999% N2:±1.5%FS
Repeatability: 99.99%~99.999% N2:±5%FS Sensor type corresponding to the analyzer:
Applications 98%~99.999% N2:±1%FS CI-PC85/-1-3O OLZL04
・ Air separation industry,such as pressure swing adsorp- 79%~99.999% N2:±0.75%FS
Technical Specifications CI-PC85/-1-4O OLZL03
tion (PSA) oxygen production; Stability: 99.99%~99.999% N2:±5%FS/7d
Sensor: electrochemical sensor 98%~99.999% N2:±1%FS/7d CI-PC85/-1-5O OLZL02
・ Detection of oxygen concentration in gas production;
Measure range: 0~25.00% O2 79%~99.999% N2:±0.75%FS/7d CI-PC85/-1-3N OLZL04
・ Detection of oxygen concentration in oxygen making
Accuracy: ±2%FS Response time: T90<30s CI-PC85/-1-4N OLZL03
equipment;
Repeatability: ±1%FS Protection level: IP64
・ Detection of oxygen concentration of gases in vegeta- CI-PC85/-1-5N OLZL02
Stability: ±1%FS/7d Power supply: 24VDC
Response time: T90<20s ble and food processing and storage; Analyzer power
Explosion-proof ・ Detection of oxygen concentration in gases in petro- consumption: <15VA
grade: Exd || CT6 chemical process; Communication: RS485(standard)/RS232(optional)
Environment
Instructions
Protection level: IP65 ・ Detection of oxygen concentration in inert gas and hydro-
Measuring method:on-line carbon gas,etc. temperature: -10~45°C Environment Humidity:<80%RH ・Application:Please refer to page 26 of this sample book.
Display: 128×64 OLED Sample flow rate:400~600ml/min ・Ordering Notes:Please refer to page 26 of this sample
Key: 3 touch keys Sample gas book.
Calibration cycle: one year (recommended) Instructions pressure: atmospheric conditions±10% (Gas outlet ・Principle:Please refer to page 46 of this sample book.
Power supply: 24VDC should be atmospheric conditions)
Principle:Please refer to page 21 of this sample book. Switch output: Alarm output:1 set
Analyzer power
consumption: <15VA Relay contact point capacity:24V DC,0.2A
Communication: RS485/RS232 Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/

27 28
Constant oxygen analyzer High content oxygen analyzer

CI-PC15/-1 CI-PC81
Explosion-proof oxygen High content oxygen
analyzer analyzer
The case of CI-PC15/-1 oxygen analyzer is designed CI-PC81 high content oxygen analyzer takes 3D ion flow
with explosion-proof design. The explosion-proof sign of Ex oxygen sensor as measuring unit and microcontroller as core.It
element is Exd II C, which is the whole flameproof structure. adopts double sensor technology and digital processing
It can be used in dangerous environment of zone 1 and zone
2 formed by explosive gases and their mixtures of Class II C technology,which makes the analyzer intelligent,high precision,-
T6 and below.The instrument is a new generation of oxygen good stability,long calibration period and long service life.The
analyzer based on zirconia concentration difference cell analyzer uses a 19-inch standard profile case with beautiful
sensor.The digital processing technology is adopted,includ- CI-PC15-1 appearance,easy installation and use.It is widely used in various
ing calibration,linearization,switching output control,current/- industrial systems to realize real-time monitoring of oxygen
voltage output and parameter setting.The analyzer has the
functions of alarm output,analog signal output,communica- concentration in nitrogen-oxygen mixture.
CI-PC15
tion and external control.
Product Features Technical Specifications Product Features Technical Specifications
・With microprocessor as the core and zirconia concen- consumption: <15VA ・With microprocessor as the core and the 3D ion flow Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/
tration cell sensor as the measuring unit,it has the charac- Communication: RS485(standard)/RS232(optional) oxygen sensor as measurement unit,it has the characteris- 1-5V,(You can set the mode freely).
teristics of intelligence,stability,high precision and long Switch output: Alarm output:1 set tics of intelligence,stability,high precision and long calibra- The load:less than 500 Ω
tion cycle. External input: Five groups
calibration cycle. Relay contact point capacity:24V DC,0.2A
・Double pool thick film co-firing technology is adopted,and Control signal 9~28VDC
・Menu lock switch:prevent misoperation and change of Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ the service life of the sensor is long. Environment
analyzer parameters from affecting its normal opera- 1-5V(You can set the mode freely). ・Automatic calibration function:The analyzer has automat- temperature: -10~45°C Environment Humidity:<90%RH
tion; The load:less than 500 Ω ic calibration function.After connecting the standard gas Sample gas
・Data Storage:Support the use of U disk and SD card to Environment according to the method specified by the manufacturer,it pressure: atmospheric conditions±10% (Gas outlet
store data,the data storage is large and easy for users temperature: -10~45°C Environment Humidity:<90%RH can complete the calibration of the analyzer automatically.
should be atmospheric conditions)
to process and analyze data; Sample flow rate:400~600ml/min ・Pressure detection function:test the relative pressure
Instrument size: L×W×H=483mm×300mm×177mm
inside the gas path,judge whether the gas path is blocked,
・Alarm function:When the oxygen concentration deviates Sample gas when the sample pressure exceeds the set range,it will
from the alarm value,the alarm value can be set freely pressure: atmospheric conditions±10% (Gas outlet give an alarm; Applications
in the full range. should be atmospheric conditions) ・Pressure compensation function:the analyzer has advanced
Inlet and outlet: 1/4-inch NPT (standard 6.5 stainless steel pressure compensation function,which can eliminate the High purity oxygen monitoring in air separation;Detection
joint) influence of pressure on the accuracy of oxygen concen- of oxygen concentration in oxygen-making equipment of
CI-PC15: L×W×H=300×200×175mm tration measurement; PSA industry;Chemical and smelting industries; Detection
Technical Specifications ・Menu lock switch:prevent misoperation and change of
Flow meter:Selection of oxygen concentration in high temperature furnace;-
Sensor: zirconia concentration difference cell analyzer parameters from affecting its normal operation;
CI-PC15-1: L×W×H=375×315×179mm Medical and health industry,such as hyperbaric oxygen
・Alarm function:When the oxygen concentration deviates
Measure range: sensor Level of explosion-proof:Exd || CT6 chamber,infant incubator,ventilator,anesthesia machine
from the alarm value,the alarm value can be set arbitrarily
Accuracy: 0~25.00% O2 (certification) in the full range. and other oxygen concentration detection;Oxygen concen-
0.01~99.9 ppm: ±5ppm ・Communication function: RS232 (standard) and RS485 tration measurement in families,ships, tunnels,deep wells,-
100~999.9ppm: ±3%FS (optional) two-way communication can be used to commu- civil air defense projects,urban tunnels,etc.
1000~9999 ppm: ±3%FS nicate directly with computers or other digital communica-
Applications tion equipment.
1.00%~25.00%: ±3% of the measured
value ・ Air separation; Order Information
Repeatability: 0.01~99.9 ppm: ±2.5ppm ・ Detection of oxygen concentration in gas production; Technical Specifications ・ Pneumatic connection mode:
100~999.9ppm: ±1.5%FS ・ Protection gas detection in semiconductor industry; A,Φ6 hose (standard);
1000~9999 ppm: ±1.5%FS ・ Protection gas detection in reflow/wave soldering; Measure range: 10.00%~97.00%/ 99.999% O2 B,connecting by using 1/4-Φ6 stainless steel cutting
1.00%~25.00%: ±1.5% of the measured ・ Gas detection in food production process; Sensor: 3D Ion flow oxygen sensor ferrule;
value Accuracy: ±1%FS C,connecting by using 1/8-Φ3 stainless steel cutting
・ Gas detection in petrochemical process;
Repeatability: ±0.5%FS ferrule;
Stability: 0.01~99.9 ppm: ±2.5ppm/7d ・ Detection of oxygen concentration in inert gas,etc. Stability: ±0.5%/7d ・ Filter:GF2800,AF2000;
100~999.9ppm: ±1.5%FS/7d
Response time: T90<20s ・ Measuring range
1000~9999 ppm: ±1.5%FS/7d Circuit structure: applied to non hazardous situations. ・ Sample gas should not contain the following substanc-
1.00%~25.00%: ±1.5% of the measured Data storage: SD Card (Standard)/U Disk (Optional)
Instructions es:
value/7d Power supply: 85~264VAC,50/60Hz 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
Response time: T90<20s (after full preheating) Ordering Notes:Please refer to page 26 of this sample Analyzer power 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
Protection level: IP64 consumption: <35VA 3.Reductive components and hydrocarbons,such as
book.
Calibration cycle: one year (recommended) Communication: RS485(standard)/RS232(optional) ethanol;
Power supply: 24VDC Switch output: 6 sets 4.Impurities,such as dust.
Analyzer power Relay contact point capacity:24V DC,0.2A

29 30
High content oxygen analyzer High content oxygen analyzer

CI-PC82 CI-PC84
High content oxygen High content oxygen
analyzer analyzer
CI-PC82 high-content oxygen analyzer uses 3D ion flow CI-PC84 high content oxygen analyzer uses 3D ion
oxygen sensor as measurement unit,combines with the flow oxygen sensor as measuring unit.After amplifying,
advanced technology in the world,breaks the traditional filtering,linearizing correction and standard signal output
magnetic mechanical detection mode,realizes pioneering of sensor signal,the oxygen concentration in nitrogen-ox-
online detection without reference gas (not affected by ambient ygen mixture is calculated by microprocessor,and the
oxygen concentration).The concentration of oxygen in the oxygen concentration display is provided.The analyzer is
mixture of nitrogen and oxygen is calculated by microcon- suitable for accurate measurement of oxygen concentra-
troller,and the oxygen concentration is displayed.It is suitable tion in nitrogen-oxygen mixture gas.
for the accurate measurement of oxygen concentration in
nitrogen-oxygen mixed gas in various industries and environ-
ments.
Product Features Technical Specifications Product Features Technical Specifications
・ Oxygen concentration,various data and the working state of should be atmospheric conditions) ・Adopt 3D ion flow oxygen sensor,which has high precision,- Relay contact
the instrument are displayed by 128*64 LCD window.The Sensor life: more than 10 years (normal use) good long-term stability and longer service life; point capacity: 24VDC,0.2A
display is intuitive and the operation is simple. Instrument life: more than 10 years (normal use) ・The surface of the window is covered with a piece of tough- Sample gas
・ It has the characteristics of intelligence,good stability,high Instrument size: L×W×D=188.5mm×98.5mm×207.5mm ened glass,which protects the LCD screen,keys, etc. pressure: atmospheric conditions±10% (Gas outlet
reliability and long calibration cycle. Installation: Disk-mounted ・The latest touch button technology is adopted to prolong should be atmospheric conditions)
・ The surface of the window is covered with a piece of tough- Mounting hole the service life of keys. Key: Four keys (touch keys)
ened glass,which protects the LCD screen and the keys. size: L×W=170mm×90mm ・Menu lock switch:prevent misoperation and change of Circuit structure: applied to non-hazardous situations.
The latest touch key technology is easy to operate and has analyzer parameters from affecting its normal operation; Calibration cycle: one year (recommended)
・ a long service life. Gas interface: 1/4-inch NPT internal thread
・Data storage function:recording test data regularly and
Menu lock switch:prevent misoperation and change of Applications querying and storing data quickly;
・ analyzer parameters from affecting its normal operation;
Alarm function:When the oxygen concentration deviates ・ High purity oxygen monitoring in air separation; ・Alarm function:When the oxygen concentration deviates Applications
・ Detection of oxygen concentration in oxygen-making from the alarm value,the alarm value can be set arbitrarily
・ from the alarm value,the alarm value can be set arbitrarily in
equipment of PSA industry; in the full range. ・ Air separation industry;
the full range.
・ Chemical and smelting industries; ・Communication function:RS232 (standard) and RS485 ・ Detection of oxygen concentration in oxygen-making
Communication function:RS232 (standard) and RS485
・ Detection of oxygen concentration in high temperature (optional) two-way communication can be used to commu- equipment of PSA industry;
・ (optional) two-way communication can be used to commu-
nicate directly with computers or other digital communica- ・ Chemical and smelting industries;
nicate directly with computers or other digital communica- furnace;
tion equipment. ・ Detection of oxygen concentration in high temperature
tion equipment. ・ Medical and health industry,such as hyperbaric oxygen
furnace;
chamber,infant incubator,ventilator,anesthesia machine
・ Medical and health industry, such as hyperbaric oxygen
and other oxygen concentration detection; chamber,infant incubator,ventilator,anesthesia machine
Technical Specifications ・ Oxygen concentration measurement in families,ships, and other oxygen concentration detection;
tunnels,deep wells,civil air defense projects,urban Technical Specifications ・ Oxygen concentration measurement in families,ships,
Measure range: 10.00%~98.00%/ 99.99% O2
tunnels,etc. Display: 128×64 LCD tunnels,deep wells,civil air defense projects,urban
Sensor: 3D Ion flow oxygen sensor
Accuracy: ±1%FS Measure range: 10%~95%/99.99% O2 tunnels,etc.
Repeatability: ±0.5%FS Accuracy: ±1%FS
Stability: ±0.5%/7d
Order Information Repeatability: ±0.5%FS
Order Information
Stability: ±0.5%FS/7d
Response time: T90<20s(after full preheating) ・ Pneumatic connection mode:
Response time: T90<15s ・ Pneumatic connection mode:
Circuit structure: applied to non-hazardous situations. A,Φ6 hose(standard);
Sensor: 3D Ion flow oxygen sensor A,Φ6 hose (standard);
Weight of analyzer:net weight 2.15kg,about 3.05kg after B,connecting by using 1/4-Φ6 stainless steel cutting Instrument weight:net weight is about 1.6 kg, after packaging B,connecting by using 1/4-Φ6 stainless steel cutting
packaging ferrule; about 2.0 kg ferrule;
Power supply: 85~264VAC,50/60Hz C,connecting by using 1/8-Φ3 stainless steel cutting Power supply: 85~264VAC,50/60Hz C,connecting by using 1/8 -Φ3 stainless steel cutting
Analyzer power ferrule; Analyzer power ferrule;
consumption: <20VA ・ Filter:GF2800,AF2000; consumption: <20VA ・ Filter:GF2800, AF2000;
Communication: RS485(standard)/RS232(optional) ・ Measuring range Environment ・ Measuring range
Relay contact ・ Sample gas should not contain the following substanc- temperature: -10~55°C ・ Sample gas should not contain the following substanc-
point capacity: 24VDC,0.2A es: Environment es:
Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/ 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc. humidity: <85%RH 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
0-10V/1-5V (You can set the mode freely). 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc. Sample flow rate:400~600ml/min 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
Environment 3.Reductive components and hydrocarbons,such as Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ 3.Reductive components and hydrocarbons,such as
temperature: -10~55°C Environment Humidity:<85%RH ethanol; 1-5V,(You can set the mode freely). ethanol;
Sample gas 4.Impurities,such as dust. Communication: RS485(standard)/RS232(optional) 4. Impurities,such as dust.
pressure: atmospheric conditions±10%(Gas outlet Alarm output: 2 set

31 32
High content oxygen analyzer High content oxygen analyzer

CI-PC86 CI-PC851/-1
High content oxygen Explosion-proof high-
analyzer content oxygen analyzer
CI-PC86 high content oxygen analyzer uses 3D ion The case of CI-PC851/-1 explosion-proof high-content
flow oxygen sensor as measuring unit.After amplifying, oxygen analyzer is designed with explosion-proof design.The
explosion-proof sign of Ex element is Exd II C,which is the
filtering,linearizing correction and standard signal output
whole flameproof structure.It can be used in dangerous
of sensor signal,the oxygen concentration in nitrogen-ox- environment of zone 1 and zone 2 formed by explosive gases
ygen mixture is calculated by microprocessor,and the and their mixtures of Class II C T6 and below.The instrument
oxygen concentration display is provided.The analyzer is is a new generation of explosion-proof high-content oxygen
suitable for accurate measurement of oxygen concentra- analyzer based on 3D ion flow oxygen sensor.After amplify- CI-PC851-1
ing, filtering,linearizing correction and standard signal output
tion in nitrogen-oxygen mixture gas. of sensor signal,the oxygen concentration in nitrogen-oxygen
mixture is calculated by microprocessor,and the oxygen
concentration display is provided. CI-PC851

Product Features Technical Specifications Product Features Technical Specifications


・Adopt 3D ion flow oxygen sensor,which has high precision, Instrument life: more than 10 years (normal use) ・ With microprocessor as the core,it has good long-term CI-PC15: L×W×H=300×200×175mm
good long-term stability and longer service life; Instrument size: L×W×H=144mm×144mm×290mm stability and high reliability. Flow meter:Selection
Installation: Disk-mounted ・ Menu lock switch:prevent misoperation and change of CI-PC15-1: L×W×H=375×315×179mm
・The latest touch button technology is adopted to prolong
Mounting hole size: L×W=136mm×136mm Level of explosion-proof:Exd || CT6
the service life of keys. analyzer parameters from affecting its normal opera-
(certification)
・The built-in one-way pump prevents the analyzer from tion;
starting up in high oxygen environment and prolongs the ・ Data Storage:Support the use of U disk and SD card to
sensor's service life. store data,the data storage is large and easy for users
・Menu lock switch:prevent misoperation and change of Applications to process and analyze data;The internal timing data Applications
analyzer parameters from affecting its normal operation; ・ Air separation industry; storage of the instrument facilitates users to view the
・ Monitoring of High Purity Oxygen in Air Separation
・ Detection of oxygen concentration in oxygen-making test data quickly. ・ Detection of oxygen concentration in oxygen-making
・Data storage function:recording test data regularly and
querying and storing data quickly; equipment of PSA industry; equipment of PSA industry;
・Alarm function:When the oxygen concentration deviates from ・ Chemical and smelting industries; Technical Specifications ・ Chemical and smelting industries;
the alarm value. ・ Detection of oxygen concentration in high temperature ・ Detection of oxygen concentration in high temperature
Measure range: 10~97.00%/99.99%,97%~99.99% O2 furnace;
・Communication function:RS232 (standard) and RS485 furnace;
Sensor: 3D Ion flow oxygen sensor ・ Medical and health industry,such as hyperbaric oxygen
(optional) two-way communication can be used to commu- ・ Medical and health industry,such as hyperbaric oxygen Accuracy: ±1%FS
chamber,infant incubator,ventilator,anesthesia machine Repeatability: ±0.5%FS chamber,infant incubator,ventilator,anesthesia machine
nicate directly with computers or other digital communica-
and other oxygen concentration detection; Stability: ±0.5%FS/7d and other oxygen concentration detection;
tion equipment. Oxygen concentration measurement in families,ships,
・ Oxygen concentration measurement in families,ships, Response time: T90<20s
Protection level:IP64 ・ tunnels,deep wells,civil air defense projects,urban
Technical Specifications tunnels,deep wells,civil air defense projects,urban
Measuring tunnels,etc.
tunnels,etc.
Measure range: 10~97.00% / 99.99%,97~99.99% O2 method: gas inlet type
Accuracy: ±1%FS Calibration cycle: one year (recommended)
Repeatability: ±0.5%FS Power supply: 24V DC
Stability: ±0.5%FS/7d Order Information Analyzer power Order Information
consumption: <25VA
Response time: T90<15s ・ Pneumatic connection mode:
・ Pneumatic connection mode: Communication:RS485(standard)/RS232(optional)
Sensor: 3D Ion flow oxygen sensor Environment A,Φ6 hose (standard);
A,Φ6 hose (standard);
Display resolution: 0.01% temperature: 0~45°C Environment Humidity:<80%RH B,connecting by using 1/4-Φ6 stainless steel cutting
B,connecting by using 1/4-Φ6 stainless steel cutting
Relay contact point Sample flow rate: 400~600ml/min ferrule;
ferrule;
capacity: 24VDC,0.2A Sample gas C,connecting by using 1/8-Φ3 stainless steel cutting
C,connecting by using 1/8-Φ3 stainless steel cutting
Power supply: 85~264VAC,50/60Hz pressure: atmospheric conditions±10% (Gas outlet ferrule;
ferrule;
Analyzer power should be atmospheric conditions) ・ Filter:GF2800,AF2000;
・ Filter:GF2800,AF2000; Switch output: Alarm output:1 set
consumption: <20VA ・ Measuring range
・ Measuring range Relay contact point capacity:24V DC,0.2A
Communication: RS485(standard)/RS232(optional) ・ Sample gas should not contain the following substanc-
・ Sample gas should not contain the following substanc- Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/
Environment es:
es: 1-5V,(You can set the mode freely).
temperature: -10~55°C 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S, etc. The load:less than 500 Ω
Environment Gas interface: 1/4-inch NPT internal thread, 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
humidity: <85%RH (standard 6.5 stainless steel joint) 3.Reductive components and hydrocarbons,such as
3.Reductive components and hydrocarbons,such as
Measuring method: gas inlet type Sensor life: more than 2 years (normal use) ethanol;
ethanol;
Sample flow rate: 400~600ml/min Instrument life: more than 5 years (normal use) 4.Impurities,such as dust.
4. Impurities,such as dust.
Flow control: built-in needle valve Measuring
Sensor life: more than 5 years (normal use) method: wall-mounted

33 34
High content oxygen analyzer High content oxygen analyzer

GNL-2100L CI-PC832
Portable high content Portable high content
oxygen analyzer oxygen analyzer
GNL-2100L portable high content oxygen analyzer CI-PC832 portable high-content analyzer uses 3D E ion
uses 3D ion flow oxygen sensor as measuring unit.After current sensor as measuring unit and combines micropro-
amplifying,filtering,linearizing correction and standard cessor with digital processing technology.It has the charac-
signal output of sensor signal,the oxygen concentration teristics of intelligence,high precision,fast response and
in nitrogen-oxygen mixture is calculated by microproces- good stability.The analyzer is suitable for measuring oxygen
concentration in various industrial and outdoor environ-
sor,and the oxygen concentration display is provided.The
ments.
analyzer has the characteristics of high precision,good The analyzer has the functions of alarm output, commu-
stability and long service life.It is suitable for measuring nication,analog signal output and so on.The 4.3 inch color
oxygen concentration in nitrogen-oxygen mixture under touch screen is used as the display window and input device
various environments. of human-computer interaction,which is rich in content,intui-
tive and convenient to operate.
Product Features Technical Specifications Product Features Technical Specifications
・With microprocessor as the core and 3D ion current sensor Sample gas ・With microprocessor as the core and 3D ion current sensor Sample gas
as the measuring unit,it has the characteristics of pressure: atmospheric conditions±10% (Gas outlet as the measuring unit,it has the characteristics of pressure: atmospheric conditions±10% (Gas outlet
intelligence,good stability,high accuracy and long calibra- should be atmospheric conditions) intelligence,good stability,high accuracy and long calibra- should be atmospheric conditions)
tion cycle. Sample flow rate: 400~600ml/min tion cycle. Sample flow rate: 400~600ml/min
・The display is intuitive and rich:the oxygen concentra- Alarm output: 1 set, ・The display frame of the analyzer is covered with a piece Inlet: Standard 1/4-Φ6 Tetrafluoro Tube Joints
tion,menu,data and working state of the instrument are Relay contact point capacity:24VDC,0.2A of toughened glass,which is not only beautiful,but also has
(Replaceable)
displayed by 128*64 LCD window,which is intuitive and Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ a good protective effect on touch screen.
・Built-in large-capacity lithium battery,in normal use,stand- Exhaust port and
rich in content. 1-5V,(You can set the mode freely).
by time is more than 3.5 hours; discharge port: Φ6 stainless steel pipe
・With the latest touch key technology,it is easy to operate Communication: RS485(standard)/RS232(optional)
and has a long service life. ・Pressure compensation function:the analyzer has the
function of pressure compensation to reduce the influence
・Long standby time:built-in large-capacity lithium battery,-
of pressure on the accuracy of oxygen concentration
standby time is no less than 8 hours in normal use; Applications
・Menu lock switch:prevent misoperation and change of
measurement,so that the measurement accuracy is higher. Applications
・ It is widely used in air separation industry,such as ・Convenient data storage function:The analyzer has the
analyzer parameters from affecting its normal operation; ・ Monitoring of High Purity Oxygen in Air Separation
function of automatically storing test data at regular
・Alarm function:When the oxygen concentration deviates pressure swing adsorption (PSA) nitrogen production;
intervals,which is convenient for understanding the test ・ Detection of oxygen concentration in oxygen-making
from the alarm value,the alarm value can be set arbitrarily ・ Chemical and smelting industries;
situation. equipment of PSA industry;
in the full range. ・ Medical and health industry,such as hyperbaric oxygen
・ Chemical and smelting industries;
chamber,infant incubator,ventilator,anesthesia machine;
・ Detection of oxygen concentration in high temperature
Technical Specifications ・ Determination of oxygen concentration in family,ship, Technical Specifications furnace;
underground command center,tunnel,deep well,civil air ・ Medical and health industry,such as hyperbaric oxygen
Measure range: 10%~97%/99.99% O2 Measure range: 10~97.00%/ 99.99%,97%~99.99%
Sensor: 3D Ion flow oxygen sensor defense engineering,city tunnel,etc. chamber,infant incubator,ventilator, anesthesia machine
Sensor: 3DE Ion flow oxygen sensor
Accuracy: ±1% FS Accuracy: ±1% FS and other oxygen concentration detection;
Repeatability: ±0.5% FS Repeatability: ±0.5% FS Oxygen concentration measurement in families,ships,
Stability: ±0.5% FS/7d Stability: ±0.5% FS/7d ・ tunnels,deep wells,civil air defense projects,urban
Response time: T90<20s (after full preheating) Order Information Response time: T90<20s (after full preheating) tunnels,etc.
Display ・ Pneumatic connection mode: Measuring medium: air or inert gas
resolution: 0.01% A,Φ6 hose (standard); Display resolution: 0.01%
Standby time: more than 8 hours B,connecting by using 1/4-Φ6 stainless steel cutting Measurement mode:portable
Sensor life: more than 2 years (normal use) ferrule; Order Information
Calibration cycle: one year (recommended)
Instrument life: more than 5 years (normal use) C,connecting by using 1/8-Φ 3 stainless steel cutting Display: 4.3-inch color touch screen
Power supply: 85~264VAC,50/60Hz ・ Pressure of the measured gas:positive pressure,micro
ferrule; Power supply: 85~264VAC,50/60Hz
Analyzer power pressure or negative pressure;
・ Filter:GF2800,AF2000; Analyzer power
consumption: <25VA ・ Measuring range;
・ Measuring range consumption: <25VA
Display: 128×64 LCD ・ Sample gas should not contain the following substanc-
Key: Four keys (touch keys) ・ Sample gas should not contain the following substanc- Standby time: more than 3.5 hours during normal test
es: Sensor life: more than 2 years (normal use) es:
Instrument
1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc. Instrument life: more than 5 years (normal use) 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
weight: net weight is about 4.2 kg
2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc. Environment 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
Environment
temperature: -10~45°C 3.Reductive components and hydrocarbons,such as temperature: -10~45°C, 3.Reductive components and hydrocarbons,such as
Environment ethanol; Environment Humidity:<80%RH ethanol;
humidity: <80%RH 4.Impurities,such as dust. Weight: 3kg±0.5kg(slightly different depending on configuration) 4.Impurities,such as dust.

35 36
Oxygen-enriched environment Oxygen-enriched environment

CI1300 CI-PC89
Oxygen monitor Monitoring instrument for
dispersion oxygen in plateau
CI1300 Oxygen Monitor adopts advanced ion flow The biggest problem of living in plateau area is lack
sensor as measuring unit.It is an intelligent monitor with of oxygen.The CI-PC89 oxygen monitor is specially
microprocessor as its core.It has two programmable designed for hotels,hotels,offices,families,storage rooms
in plateau area. It monitors the oxygen concentration in
alarm signals (Alarm) output,a set of RS485 bidirectional
the environment in real time,and adjusts the oxygen
data communication interface or a set of 0/4-20mA
concentration in the room by controlling the oxygen
analog output.It can conduct real-time monitoring of supply valve switch,so as to make it in the best state
oxygen concentration in 0 ~ 40% nitrogen-oxygen mixed needed by the human body to work and rest,and improve
gas. the working efficiency and the overall health level of the
plateau people.

Product Features Technical Specifications Product Features Technical Specifications


・Ion flow sensors with long life,high precision and fast Chassis: metal chassis (spray paint) ・Using 3DE ion flow oxygen probe as the measuring cally.When the oxygen concentration is
response time are used. Key: Four key (switch mask) unit,adopting advanced digital processing technology,an- below the control value,the oxygen supply
・It can be applied to the measurement of oxygen concen- Sensor room: Aluminum Alloy Nickel-plated, ti-cross interference,high measuring precision,good stabil- valve is automatically opened,and the
tration in nitrogen-oxygen mixture gas. Tightening Type ity and long service life; oxygen is fed into the room.
・It integrates oxygen monitoring and control,and realizes Control accuracy: 0.5%
・The alarm value can be set arbitrarily in the whole Measuring method: on-line
the adjustment of the ambient oxygen concentration while Oxygen pressure: 0.2~0.6MPa
range,and single point control or range control can be Relay contact point
measuring the change of the ambient oxygen,so as to Oxygen inlet: Φ6 Quick Connector
selected. capacity: 24VDC,0.2A
achieve the best adaptation of the human body to the Oxygen outlet: diffusion,noise reduction
・Man-machine dialog menu in Chinese is intuitive and Circuit structure: applied to non-hazardous situations.
environment. Anion: Built in anion generator,which can be
convenient to operate. Weight: 1.4kg net,2.1kg after packaging
・Metal Shell,Safe and Reliable switched by remote control
・A variety of communication commands can be easily Packing case size: L×W×H=300mm×240mm×175mm ・The invention has remote control function and convenient use Communication: RS485 communication or wireless
controlled or data exchanged through the upper comput- ・Monitor supports RS485 communication communication (optional)
er. ・The invention has the functions of releasing negative Switching signal: Quantity:1 group
・Unique sensor probe design makes it easy to replace Applications oxygen ions,improving the function of ventilation of the Purpose:Switching signal output for
sensors on site. alveolar and enhancing the oxygen concentration control of second group
CI1300 oxygen monitor is suitable for monitoring oxygen
・The oxygen outlet adopts noise reduction treatment to Relay contact capacity:24VDC,0.2A
concentration in nitrogen-oxygen mixture or air,and can External control
Technical Specifications meet the noise requirement of sleep
be widely used in medical and health industry; ・The invention can display the oxygen concentration of the Signal: Quantity:1 group Purpose:switch monitor
Measure range: 0~40% O2 Chemical and smelting industries; environment and also can display the simulated altitude control signal:220VAC±10%,50/60Hz
Measurement mode: gas diffuser Detection of oxygen concentration in the process of vegeta- and the absolute altitude,and can be directly switched Power: 85~264VAC,50/60Hz
Accuracy: ±1.5%FS ble and food processing and storage; through the remote control Monitor power: <15VA
Repeatability: ±1%FS Detection of oxygen/nitrogen concentration in family,naval Shell: Metal Shell (Toughened Glass on Front)
Stability: ±1%FS/7d vessel,underground command center,tunnel,deep well,civil Dimension: L×W×H=386mm×256mm×76mm
Response time: T90<30s air defense engineering,urban tunnel,etc. Technical Specifications Weight: Weight around 4.2kg,after packaging
Sensor: Ion flow oxygen sensor around 5.7kg
Sensor: 3DE ion flow oxygen sensor Display:
Display: 128×64 LCD 120×70 LCD
Measurement Operation mode: Remote control,remote control (com-
Display resolution: 0.01%
range: 0~40.00% O2
Power supply: AC220V±10%,50/60Hz munication)
absolute elevation:0~6000m Power switch: have
Alarm output: two groups of programmable Order Information Accuracy: ±1%FS
alarm output Panel color: Starry Black (standard), local gold
・ Pressure of the measured gas:positive pressure,micro Repeatability: ±0.5%FS Ambient
Communication: RS485 Accuracy: ±0.5%FS/7d
Select a set of pressure or negative pressure; temperature: -10~+50°C
Response time: T90<20s Environmental
analog outputs: 4-20mA/0-20 mA/0-10V ・ Sample gas should not contain the following substanc-
Oxygen humidity:
Environment es: Less than 80% RH,no condensed water
concentration Work pressure: atmospheric pressure±10% (Outlet
temperature: 0~+45°C 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc. control: Switch of oxygen supply valve should be atmospheric pressure)
Environment humidity: <80%RH 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc. controlled by microcontroller
Composition of 3.Reductive components and hydrocarbons,such as Control mode: automatic control
Measured gases: Nitrogen-Oxygen Mixture ethanol; Automatic
4.Impurities,such as dust. control principle: When the oxygen concentration in the
Applications
Calibration cycle: one year (recommended)
Installation: wall-mounted room is higher than the control value,the The hotel,motel,office,family,home,hospital,storage room
Calibration gas: air oxygen supply valve is closed automati- and other indoor places in plateau areas

37 38
Oxygen-enriched environment Oxygen-enriched environment

CI-PC894 CI-PC836
Series-monitoring Oxygen content/oxygen
instrument for dispersion oxygen in plateau partial pressure analyzer
The CI-PC894 series monitor for the diffuse oxygen in CI-PC836 Oxygen content/oxygen partial pressure
the plateau is designed to detect and control the oxygen in analyzer uses 3D ion current sensor as measuring unit and
the environment in the hotel,hotel,office,home,hospital,stor- combines microprocessor with digital processing technolo-
age room and other indoor places.The lack of oxygen caused gy. It has the characteristics of intelligence, high precision,-
by the low oxygen partial pressure in the special environment fast response and good stability.The analyzer is suitable for
such as the plateau will directly affect people's health and measuring oxygen concentration in various industrial and
comfort degree.In addition,some long-closed rooms may also outdoor environments.
have an oxygen deficiency,which could lead to suffocation.The The analyzer has the functions of alarm output, commu-
main function of the monitor is to detect the change of the nication,analog signal output and so on.The 4.3-inch color
oxygen concentration in the environment in real time,and to touch screen is used as the display window and input device
control the oxygen supply switch automatically to realize the of human-computer interaction,which is rich in content,intui-
stable control of the oxygen concentration in the environment. tive and convenient to operate.
Product Features Accessory Project Product Features Technical Specifications
・Using 3DE ion flow oxygen sensor as measurement Scenario 1:CI-PC894 oxygen monitor+CI-MS01 dispersion terminal (1-3) ・With microprocessor as the core and 3D ion current Sampling gas
unit,adopting advanced digital processing technolo- sensor as the measuring unit,it has the characteristics temperature: 0~50°C
gy,anti-cross interference,high measurement accura- of intelligence,good stability,high accuracy and long Sample gas
cy,good stability,long service life calibration cycle. pressure: atmospheric conditions±10% (Gas outlet
・The invention realizes the adjustment of the environ- ・The 4.3-inch color touch screen is used as the display should be atmospheric conditions)
mental oxygen concentration while measuring the
environmental oxygen change,so as to achieve the best + window and input device for human-computer interac-
tion.The display content is rich,intuitive and the opera-
Sample flow rate: 400~600ml/min
Inlet: Standard 1/4-Φ6 Tetrafluoro Tube Joints
adaptation of the human body to the environment tion is very convenient. (Replaceable)
・Easy to use by button or infrared remote controller Scenario 2:CI-PC894 oxygen monitor+CI-MS02-1 dispersion terminal (1-3)
・The display frame of the analyzer is covered with a Communication: RS485/RS232
・Support IC card card to take oxygen (optional)
piece of toughened glass,which is not only beautiful, Switch output: Alarm output:1 set
・Enables distribution network integration management
but also has a good protective effect on touch screen. Relay contact point capacity:24V DC,0.2A
(optional)
・Built-in large-capacity lithium battery,in normal use, stand- Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/

+
・Oxygen concentration,oxygen partial pressure,relative
altitude,absolute altitude free switching by time is more than 3.5 hours; 1-5V,(You can set the mode freely).
・Pressure compensation function:the analyzer has the The load:less than 500 Ω
function of pressure compensation to reduce the
Technical Specifications Scenario 3:CI-PC894 oxygen monitor+CI-MS02-2/3 dispersion terminal (1) influence of pressure on the accuracy of oxygen concen-
tration measurement,so that the measurement accura-
Applications
Measurement
Principle: 3DE ion flow oxygen sensor cy is higher. ・ Monitoring of oxygen concentration in air separation;
measurement ・Convenient data storage function:The analyzer has the ・ Detection of oxygen concentration in oxygen-making
range:
Accuracy:
0~40.00% O2
±1% FS + function of automatically storing test data at regular
intervals,which is convenient for understanding the test
situation.
equipment of PSA industry;
・ Chemical and smelting industries;
Repeatability: ±0.5% FS Option 4:Mix and match(diffusion terminal total 3 channels) ・ Detection of oxygen concentration in high temperature
Stability: ±0.5% FS/7d CI-PC894 oxygen monitor+CI-MS02-1 dispersion terminal+ furnace;
Response time:T90<20s CI-MS01 dispersion terminal
Technical Specifications ・ Medical and health industry,such as hyperbaric
Concentration oxygen chamber,infant incubator,ventilator, anesthe-
Display: Oxygen content (%) Measure range: 1~40kPa O2 sia machine and other oxygen concentration detec-
Oxygen partial pressure (kPa) Sensor: 3D Ion flow oxygen sensor
+ +
tion;
Relative altitude (m in units) Accuracy: ±1% FS ・ Oxygen concentration measurement in families,ships,
Absolute altitude (m in units) Repeatability: ±0.5% FS
Scenario 5:Mix (Total 3 Paths for Dispersed Terminals) tunnels,deep wells,civil air defense projects,urban
Power: 100~240VAC,50/60Hz Stability: ±0.5% FS/7d
CI-PC894 oxygen monitor +CI-MS02-2 dispersion terminal+ tunnels,etc.
input power: < 20VA CI-MS01 dispersion terminal Response time: T90<15s
Display: 120×70 LCD Display resolution:0.01%
Use Measurement Order Information
environment: Temperature: -10 to 50°C Humidity:<80%RH mode: portable

+ +
No Cold Water Calibration cycle: one year (recommended) ・Pressure of the measured gas:positive pressure,micro
Storage Power supply: 220VAC±,50/60Hz pressure or negative pressure;
environment: Temperature: -20 to 60°C Humidity:<80%RH Scenario 6:Mix (Total 3 Paths for Dispersed Terminals) Analyzer power ・Measuring range;
No Cold Water; CI-PC894 oxygen monitor +CI-MS02-2 dispersion terminal+ consumption: <15VA ・Sample gas should not contain the following substances:
Panel color: When the storage and transportation environ- CI-MS02-1 dispersion terminal Standby time: more than 3.5 hours during normal test 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
ment temperature is below 5°C, the equip- Sensor life: more than 36 months (normal use) 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
ment should be placed in the normal operat- Instrument life: more than 60 months (normal use) 3.Reductive components and hydrocarbons,such as
ing temperature environment for more than Weight: 3kg±0.5kg (slightly different depending
+ +
ethanol;
4 hours before use. on configuration) 4.Impurities,such as dust.
ivory, gold, gray sky

39 40
Oxygen-enriched environment Oxygen transmitter

CI-PC896 GNL-B5/CI-PC981
Monitoring instrument for Micro oxygen transmitter
dispersion oxygen in plateau
The CI-PC896 monitor for the diffuse oxygen in the With the development of intelligent technology,system
plateau is designed to detect and control the oxygen in the integration has been applied in various fields of automatic
environment in the hotel,hotel,office,home,hospital,storage control.Sensors are like nerve endings of the system.They
room and other indoor places.The lack of oxygen caused by perceive the changes of physical or chemical quantities in the
the low oxygen partial pressure in the special environment environment.The circuit module of the transmitter completes
such as the plateau will directly affect people's health and
the interface work between the sensor and the system,so
comfort degree.In addition,some long-closed rooms may also
that the control part of the system can make a reasonable
have an oxygen deficiency,which could lead to suffocation.The
judgment.Oxygen sensor and circuit module are combined
main function of the monitor is to detect the change of the
oxygen concentration in the environment in real time, and to to form an oxygen transmitter,which can provide standard
control the oxygen supply switch automatically to realize the signals directly to users.It can greatly facilitate users second-
stable control of the oxygen concentration in the environment. ary processing of oxygen signals.

Product Features Technical Specifications Product Features Technical Specifications


・The oxygen flow rate range is:0.5~30L/min,adjustable No Cold Water;When the storage and ・Adopt fuel cell oxygen sensor with world advanced level; Sample flow rate: 800~1000ml/min
Noise less than 40dBA transportation environment temperature ・The measuring range is 0~100ppm by default,and 0~10ppm Weight: 1.2kg
・Oxygen concentration monitoring:Adopting the world's is below 5°C,the equipment should be /0~100ppm/0~1000ppm/0~1%/0~25%,it can be manual- Selection instructions:
most advanced ion flow sensors placed in the normal operating tempera- ly adjusted (ci-pc981).
・(3D ion flow) is a measurement unit.The design life of ture environment for more than 4 hours ・Intelligent micro-control technology is adopted in circuit Model Installation mode Security Category
3D ion flow sensor is longer than 10 years,which is Switch amount/ design. GNL-B5 KF40(Standard Type) ordinary
twice as long as the ordinary ion flow sensor.real-time Voltage Output: Switch Amount:3 groups ・High accuracy,good stability and low power consumption; GNL-B5-1 Thread type(M51×1.5mm) ordinary
online monitoring indoor air oxygen concentration to (Two choose one) Relay contact capacity:24VDC,0.2A ・Long service life,small size,simple structure; CI-PC981 KF40(Standard Type) Intrinsically safe
ensure safe use; Voltage output:Three groups of 5~12- ・KF40 and thread (M51*1.5) can be selected for installa-
CI-PC981-1 Thread type(M51×1.5mm) Intrinsically safe
・Integrated oxygen monitoring and control,while measur- VDC can be used to control external sole- tion.
ing the changes of environmental oxygen,achieve the noid valves ・It is easy to use and maintain.
adjustment of the ambient oxygen concentration; Each group less than 7VA Applications
・Provide oxygen content, simulated altitude, absolute Communication: RS485 (standard),RS232 (optional),WIFI
altitude,oxygen partial pressure,humidity,oxygen supply (Five choose one) (optional),Bluetooth (optional),WAN ・ Glove box;Air separation;
flow and other parameters display; (Selected) Model: GNL-B5/CI-PC981 ・ Chemical and smelting industries;
・Supports RS485/Serial communication,WAN port communi- Diffuse terminal: CI-MS01,CI-MS02,CI-MS05 Measure range: 0-10/100/1000 ppm O2 ・ Nitrogen,argon and natural gas
cation,WIFI and Bluetooth; (Three choose one) Accuracy: 0.01~9.99ppm O2:±5% FS pipelines;
・It has infrared remote control function and is conve- 10.0~99.9ppm O2:±3% FS ・ Detection of oxygen concentration
nient to use. 100~1000ppm O2:±2% FS in protective gas of semiconductor;
Display: Repeatability: 0.01~9.99ppm O2:±2.5% FS ・ Detection of oxygen concentration
10.0~99.9ppm O2:±1.5% FS
Technical Specifications Display content Unit Display resolution 100~1000ppm O2:±1% FS
in high temperature furnace,etc.
Measurement Oxygen content % 0.01% Stability: 0.01~9.99ppm O2:±2.5% FS/7d
principle: 3D ion flow sensor 10.0~99.9ppm O2:±1.5% FS/7d
Order Information
Measurement Oxygen partial pressure kPa 0.01kPa 100~1000ppm O2:±1% FS/7d ・ Pneumatic connection mode:A,Φ6 hose (standard);B,
range: 0~40.00% O2 Simulated altitude M(metre) 1m Response time: T90≤60s connecting by using 1/4-Φ6 stainless steel cutting
Accuracy: ±1% FS Sensor: Fuel cell oxygen sensor
Absolute altitude M(metre) 1m ferrule;C,connecting by using 1/8-Φ3 stainless steel
Repeatability: ±0.5% FS Analyzer power
cutting ferrule;
stability: ±0.5% FS/7d atmospheric pressure kpa 0.01kpa consumption: <10VA
response time:T90<20s ・ Pressure of the measured gas:positive pressure,micro
Analog output: 4~20mA(Load resistance is not more
Power: 85~264VAC,50/60Hz oxygen supply flow L/min 0.01L/min pressure or negative pressure;
than 500 Ω)
Input powe: ≤20VA environmental humidity %(relative humidity) 0.1% GNL-B5 the current signal output is ・ The main components of the measured gas:whether it
Control mode:Touch,infrared remote,remote control 4-wire system contains CO2,H2S,SO2,NOx,NH3 and other gases.
ambient temperature °C 0.1°C
(communication) CI-PC981 the current signal output is
Use CO2 concentration ppm 1ppm 2-wire system Instructions
environment: -10~50°C Humidity:<80%RH,No Cold Water Power supply: 24VDC,0.42 A
PM2.5 ug/m 3
1ug/m 3
・Sensor principle:please refer to page 2 of this sample
Measuring Environment
media: Gases or inert gases cannot contain corrosive temperature: 0~45°C book;
gases (such as HF,Cl2,HCl,SO2,H2S,etc.), Environment ・Interference effects of various gases on measurement:
Order Information
toxic substances (such as Si,Pb,P,Zn,Sn,As,etc.) humidity: <90%RH(25°C) please refer to page 15 of this sample book.
Storage The hotel,motel,office,family,home,hospital,storage room Sample
environment: Temperature:-20 to 60°C Humidity:<80%RH, and other indoor places in plateau areas temperature: 5~45°C

41 42
Oxygen transmitter Oxygen transmitter

CI-PC98-1/2/3 CI-PC881
Oxygen analyzer Oxygen/Nitrogen transmitter
CI-PC98-1/2/3 series oxygen analyzer takes microcon- CI-PC881 oxygen/nitrogen transmitter uses ion flow
troller as its core and fuel cell oxygen sensor as its measur- oxygen sensor as measuring unit.After amplifying,filter-
ing unit.It is suitable for measuring oxygen content in various ing,linearizing correction and standard signal output of
working conditions.It has the characteristics of intelligence,high
sensor signal,the oxygen concentration in nitrogen-oxy-
precision,fast response and good stability.The analyzer uses
gen mixture is calculated by microprocessor,or use the
128*64 LCD screen as the window,which is intuitive and rich
in content.The user can set the parameters freely,and the oxygen concentration value to calculate the nitrogen
operation is simple.It has three installation modes:gas pipe concentration value,and output a set of analog signals or
connection,flange installation and thread installation,which communications.
can meet different installation requirements.

Product Features Applications Product Features Technical Specifications


・The fuel cell type oxygen sensor is used as the measuring ・ Air separation; ・It has the characteristics of intelligence,good stability,high Sensor: Ion flow oxygen sensor
unit,adopting advanced digital processing technology,an- ・ Gas production and testing; reliability and long calibration cycle. Accuracy: 10ppm~100ppm O2 ±5%FS
ti-cross interference,high measuring accuracy and good ・ Gas detection in petrochemical process; ・The circuit adopts digital signal processing,isolation and 10ppm~2% O2 ±2%FS
stability. ・ Detection of oxygen concentration in inert gas and amplification,frequency cut-off design,and has strong anti-in- 10ppm~21% O2 ±1.5%FS
・Using the most advanced temperature compensation- hydrocarbon gas,etc. terference ability. Repeatability: 10ppm~100ppm O2 ±2.5%FS
・ Detection of oxygen concentration in food production, ・Menu lock switch:prevent misoperation and change of 10ppm~2% O2 ±1%FS
method of oxygen analyzer,its temperature compensation
packaging and storage; analyzer parameters from affecting its normal operation; 10ppm~21% O2 ±0.75%FS
・effect is world leading. ・ Detection of Oxygen Concentration in Semiconductor ・Communication function (optional):support RS485/RS232 Stability: 10ppm~100ppm O2 ±2.5%FS/7d
prevent misoperation and change of analyzer parameters Protection Gas communication; 10ppm~2% O2 ±1%FS/7d
from affecting its normal operation; ・ Detection of Oxygen Concentration in Gas during ・The utility model has the advantages of simple structure, 10ppm~21% O2 ±0.75%FS/7d
Heating and Annealing convenient installation and maintenance. Response time: T90<20s (after full preheating)
Technical Specifications Selection CI-PC98-X-X-X
Model specification Instrument weight:about 0.5kg
Sensor: Fuel cell type instructions: Test chamber (excluding CI-PC98-3): Power supply: 24VDC,Analyzer power consumption:<10VA
G : GE

Power supply: 24VDC,0.42 A K : KF40


Y : Organic glass
Display mode Instrument Model measuring range Environment
Analyzer power The following test chambers are dedicated to CI-PC98-3:
G25 : GE temperature: -10~55°C,Environment Humidity:<80%RH
consumption: <1VA
K25 : KF40
Y25 : Organic glass CI-PC881-3O(-D) 0.1% ̄21.0% O2 Sample flow rate:400~600ml/min
Environment Function configuration:
Oxygen Analog output
A : No output CI-PC881-4O(-D) 100ppm ̄21.00% O2
temperature: 0~45°C Environment Humidity:<90%RH
B : A set of analog outputs
C : Two sets of analog output (O2)Display (standard): free setting
Analog output: 4~20mA(Load resistance is not more than 500 Ω)
D : Communication
E : Communication and a set of analog outputs CI-PC881-5O(-D) 10ppm ̄21.000% O2 4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V
Sample Measure Range:
CI-PC881-3N(-D) 79.0% ̄99.9% N2 Communications:RS485(standard)/RS232(optional)
Nitrogen
None:0-1000ppm
1 :10-10000ppm
temperature: 5~45°C 2 :100ppm-25.00%

Sample flow rate:800~1000ml/min


3 :0.1%-25.00%
(N2)display CI-PC881-4N(-D) 79.00% ̄99.99% N2
Order Information
CI-PC98 Series Oxygen Analyzer

CI-PC881-5N(-D) 79.000% ̄99.999% N2
Model Measure Range Accuracy Repeatability Stability Response Time ・ Pressure of the measured gas:positive pressure,micro
Analyzer model Sensor type pressure or negative pressure;
0~10ppm O2: ±5%FS 0~10ppm O2: ±2.5%FS 0~10ppm O2: ±2.5%FS/7d
CI-PC881-3N OLZL04 ・ Filter:GF2800,AF2000;
CI-PC98 0~1000ppm O2 0~100ppm O2: ±3%FS 0~100ppm O2: ±1.5%FS 0~100ppm O2: ±1.5%FS/7d T90<60s(25°C)
・ Output configuration (one of three options,please speci-
CI-PC881-3O OLZL04
0~1000ppm O2: ±2%FS 0~1000ppm O2: ±1%FS 0~1000ppm O2: ±1%FS/7d fy when ordering):analog output (standard),RS485
CI-PC881-4N OLZL03 communication,RS232 communication;
10~100ppm O2: ±3%FS 10~100ppm O2: ±1.5%FS 10~100ppm O2: ±1.5%FS/7d
CI-PC881-4O OLZL03 ・ Sample gas should not contain the following substanc-
CI-PC98-1 10~10000ppm O2 100~1000ppm O2: ±2%FS 100~1000ppm O2: ±1%FS 100~1000ppm O2: ±1%FS/7d T90<60s(25°C) es:
CI-PC881-5N OLZL02
1000~10000ppm O2: ±2%FS 1000~10000ppm O2: ±1%FS 1000~10000ppm O2: ±1%FS/7d 1.Corrosive gases,such as HF,Cl2,HCl,etc.
CI-PC881-5O OLZL02 2.Toxic substances,such as Si,Pb,P,etc.
100~1000ppm O2: ±2%FS 100~1000ppm O2: ±1%FS 100~1000ppm O2: ±1%FS/7d
3.Reductive components and hydrocarbons,such as
CI-PC98-2 100ppm~25.00% O2 1000~10000ppm O2: ±2%FS 1000~10000ppm O2: ±1%FS 1000~10000ppm O2: ±1%FS/7d T90<60s(25°C) Applications ethanol;
PSA industry;air separation industry;Chemical and smelting 4.Impurities,such as dust.
1.00~25.00% O2: ±2%FS 1.00~25.00% O2: ±1%FS 1.00~25.00% O2: ±1%FS/7d
industries;Detection of oxygen concentration in high tempera-
ture furnace;Detection of oxygen concentration in protective
CI-PC98-3 0.1%~25.00% O2 ±2%FS ±1%FS ±1%FS/7d T90<20s
gases of semiconductors;Detection of oxygen concentration
Instructions
in the process of vegetable and food processing and storage;- Principle:Please refer to page 46 of this sample book.
Order Information Detection of oxygen concentration in family,naval vessel,un-
derground command center,tunnel,deep well,civil air defense
The main components of the measured gas:whether it contains CO2,H2S,SO2,NOx,NH3 and other gases. engineering,urban tunnel,etc.

43 44
Oxygen transmitter Oxygen transmitter

GNL-120-1/3 GNL-3100
Oxygen transmitter Series oxygen/nitrogen transmitter
GNL-120-1/3 oxygen transmitter with microcontrol- The GNL-3100 series oxygen/nitrogen sensor is used
ler as the core and zirconia concentration cell sensor as as the measuring unit,and the oxygen concentration value
the measurement unit,the transmitter is suitable for the in the nitrogen-oxygen mixture is directly calculated
measurement of oxygen content in various working condi- through the signal processing of the microprocessor,and
tions.The calibration,linearization,switching output,analog the oxygen concentration value is directly displayed,or the
nitrogen concentration value is provided after the
output signal and parameter setting of the transmitter all
nitrogen concentration value is calculated by the oxygen
use digital processing technology.It has the characteris-
concentration value.The analyzer has a programmable
tics of intelligence,high precision,quick response and good alarm value,a programmable current (4-20mA) output,a
stability. set of alarm switch output.

Product Features Technical Specifications Product Features Model description


・Using zirconia concentration cell sensor as the Environment ・ A new type of long-life ion flow detector is introduced Display mode Model Measurement range
measurement unit,adopting advanced digital process- temperature: -10~+50°C Environment Humidity:<80%RH in this paper. It has high precision and fast response. GNL-3100-3O 0.1%~21.0% O2
ing technology,anti-cross interference, high measure- ・ N2,O2 display for user selection
ment accuracy,good stability and long service life of Sample gas Oxygen display GNL-3100-4O 100ppm~21.00% O2
・ Automatic detection of sensor working state,unique
sensor; pressure: atmospheric conditions±10% (Gas outlet protection switching mode,extended sensor life GNL-3100-5O 10ppm~21.000% O2
・It can achieve a wide range of testing from ppm level should be atmospheric conditions) ・ Alert values can be set arbitrarily GNL-3100-3N 79.0%~99.9% N2
to% level. Storage environment: -10~+50°C,environmental humidity less ・ The high precision temperature automatic compensa- Nitrogen display GNL-3100-4N 79.00%~99.99% N2
・Communication function:support RS485 or RS232 com- than 90%RH,no condensed water.When the tion system eliminates the influence of environmental GNL-3100-5N 79.000%~99.999% N2
munication; storage and transportation environment temperature.
・Isolated analog signal output can be freely set to temperature is lower than 5°C,the transmit- Principle
0-20mA/4-20mA/0-1V/0-5V/0-10V/1-5V analog output ter should be placed in the normal working
mode. temperature environment for more than 4 Technical Specifications PT leads

hours before use. anode


Display: 5-bit digital LED dynamic display
Visual Window 90×25 mm
Technical Specifications
Accuracy: 10~99.9ppm O2:±5%FS PT heater
Heat to 700°C
Sensor: Zirconia concentration cell sensor Applications 100~999ppm O2:±2%FS Fixed electrode
Measure range: 0~25.00% O2 1000ppm~21% O2:±1.5%FS (Zirconium oxide)
Accuracy: 0.01~99.9 ppm: ±5ppm ・ Glove box;
Repeability: 10~99.9ppm O2:±2.5%FS
100~999.9ppm: ±3%FS ・ Air separation,such as PSA,for oxygen production;
・ Detection of oxygen concentration in wood,building 100~999ppm O2:±1%FS cathode PT leads
1000~9999 ppm:±3%FS 1000ppm~21% O2:±0.75%FS
1.00%~25.00%: ±3% of the measured value materials and paper industry; Porous alumina substrate
・ Detection of oxygen concentration during food produc- Stability: ±1%FS/7d PT leads
Repeatability: 0.01~99.9 ppm: ±2.5ppm
tion,packaging and storage; Response time: T90<20 second (fully preheated) Platinum electrodes are coated on both sides of the
100~999.9ppm: ±1.5%FS ・ Working stabilized ZrO2,and the cathode side is bonded with a cover
1000~9999 ppm:±1.5%FS ・ Petrochemical and smelting industries; temperature: 0~50°C with a gas diffusion hole to form a cathode cavity.At a certain
1.00%~25.00%:±1.5% of the measured value Detection of oxygen concentration of semiconductor
Environmental temperature,if a certain voltage is applied to both sides of the
0.01~99.9 ppm: ±2.5ppm/7d ・ shielding gas; ZrO2 electrode,the oxygen molecules in the cavity form oxygen
Detection of oxygen concentration in high temperature humidity: <80%RH
Stability: 100~999.9ppm: ±1.5%FS/7d ions (O2-) at the cathode,and O2- migrates to the anode through
1000~9999 ppm:±1.5%FS/7d furnace. Working power
the oxygen vacancies of ZrO2,and then releases the electrons
1.00%~25.00%:±1.5% of the measured val- supply: AC220V±10% 50/60Hz,or 24VDC
into the oxygen molecule gas.This phenomenon is called
ue/7d Power waste: ≤6VA electrochemical pump,so that the oxygen in the cathode
Response time: T90<20s (after full preheating) Analog output cavity is continuously released by the ZrO2 electrolyte source
Power supply: 24VDC Order Information signal: 4 to 20 mA (allowing external load<500Ω) The pump is pumped out of the cavity,forming a current in
Transmitter power: <25VA Relay contacts the loop.When the oxygen mole fraction is constant,the
・ Choose one of analog output signal,RS485,RS232, and capacity:
Weight: about 1.05kg DC24V,0.2A voltage increases,the current intensity increases.When the
the user shall explain to the supplier when ordering;
Calibration point: Recommendations:20.60%,1%,500ppm, Sensor principle: Ion flow voltage exceeds a certain value,the current intensity reaches
・ The tested environment should not contain corrosive saturation,which is the result that oxygen diffusion into the
50ppm,10ppm Sensor life: >18000 hours (normal use)
gases,(such as HF,Cl2,HCl,SO2,H2S,etc.)toxic substances, cathode cavity through the small hole is limited by the small
GNL-120-1-A
(such as Si,Pb,P,Zn,Sn,As,etc.) reductive components Dimensions: L×W×H=153mm×131mm×57mm
(standard): 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ Installation hole.This saturation current is called the limit current.
and hydrocarbons,(such as ethanol);water vapor,etc.
1-5V,(You can set the mode freely). dimensions: L×W=111mm×118mm Instructions
GNL-120-1-B: RS485 Communication Analyzer weight: Around 0.7kg ・Order Notice:See page 44
GNL-120-1-C: RS232 Communication ・Applications:See page 14

45 46
Oxygen transmitter Oxygen transmitter

CI-PC882 CI-PC85-2
Ambient oxygen transmitter Explosion-proof oxygen/
nitrogen analyzer
The CI-PC882 oxygen monitoring instrument uses 3D The explosion-proof sign of Ex element used in
ion flow oxygen sensor as the measuring unit,after the CI-PC85-2 oxygen/nitrogen analyzer is Exd II CT6,which is an
sensor signal amplification,filtering,linearization correc- integral explosion-proof structure.It can be used in danger-
tion and other electrical processing,the oxygen concen- ous environment formed by explosive gases and their
tration value in the nitrogen-oxygen mixture gas is calcu- mixtures of Class II C T6 and below.
The analyzer uses 3D ion flow sensor as measuring unit,
lated by the microprocessor,and a group of analog signals
which can measure oxygen concentration accurately in
are output,or through RS485/RS232 communication with various environments,and provide oxygen concentration
the computer or other digital communication equipment display,or calculate nitrogen concentration in nitrogen-oxy-
gen mixture according to oxygen concentration value,and
provide nitrogen concentration display.

Product Features Technical Specifications Product Features Technical Specifications


・The new ion flow oxygen sensor has high precision,- Model: CI-PC882 ・The combination of microcontroller and digital processing Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/
good stability and short response time. Display resolution:0.01% technology can achieve cross-interference resistance, 1-5V,(You can set the mode freely).
・Menu lock switch:It can prevent the error operation stability and reliability. The load:less than 500 Ω
Sensor: ion flow oxygen sensor
from changing the parameters of the analyzer and ・The 3-D ion flow sensor has high precision,good stability Sample flow rate: 400~600ml/min
Measurement and long service life.
affecting its normal operation. Sample gas
・RS232/485 Bi-Directional Communication:When choos- range: 0~40.00% O2 ・The latest touch button technology is easy to operate and pressure: atmospheric conditions±10% (Gas outlet
ing to configure communication,it can communicate Accuracy: ±1%FS has a long service life. should be atmospheric conditions)
directly with computers or other digital communication Repeatability: ±0.5%FS ・With infrared remote-control function,the analyzer can be
operated by remote control. Model Test scope
devices. Stability: ±0.5% FS/7d Display mode
・Freely set analog output mode:When the analog output ・Menu lock switch:prevent misoperation and change of Display of CI-PC85-2-3O 1000ppm~21.0% O2
Response time: T90<20 second (Fully Preheated) analyzer parameters from affecting its normal operation; oxygen (O2) CI-PC85-2-4O 100ppm~21.00% O2
is selected,the analog output modes of 4-20mA,0-20mA,
Sensor life: Greater than 5 years (normal use) ・The explosion-proof design is adopted,and the explosion- concentration CI-PC85-2-5O 10ppm~21.000% O2
0-1V,0-5V,0-10V,1-5V can be freely set through the menu;
Analyzer life: proof grade reaches Ex II CT6. CI-PC85-2-3N 79.0%~99.9% N2
・Optional sensor built/external:The sensor can be Greater than 10 years (normal use) Display of
・Alarm function:When the oxygen concentration deviates nitrogen (N2) CI-PC85-2-4N 79.00%~99.99% N2
arranged inside the instrument according to the needs Calibration period:1 year (recommend) from the alarm value,the alarm value can be set arbitrarily concentration CI-PC85-2-5N 79.000%~99.999% N2
of users,and can be independent components,and Power supply: 24V DC power consumption less than within the full range.
connected with the instrument through leads; 10VA Analyzer model Sensor Model
・Choose whether to have a monitor:Choose whether the CI-PC85-2-3O OLZL04
ambient Technical Specifications
instrument has a monitor or a stand-alone monitor CI-PC85-2-4O OLZL03
(CI-PC88-X Operator Panel) as required by the user temperature: -10~55°C
CI-PC85-2-5O OLZL02
・The invention has simple structure and convenient environmental Sensor: 3D Ion flow oxygen sensor
CI-PC85-2-3N OLZL04
installation and maintenance. Accuracy: 99.99%~99.999% N2:±10%FS
humidity: <80%RH CI-PC85-2-4N OLZL03
98%~99.999% N2:±2%FS
sample pressure: atmospheric pressure CI-PC85-2-5N OLZL02
79%~99.999% N2:±1.5%FS
Installation mode: Bottom bracket installation Repeatability: 99.99%~99.999% N2:±5%FS
Circuit structure: Apply to non-hazardous occasions 98%~99.999% N2:±1%FS Applications
Measurement 79%~99.999% N2:±0.75%FS
Stability: 99.99%~99.999% N2:±5%FS/7d ・Air separation industry,such as pressure swing adsorption
method: diffusion
Applications 98%~99.999% N2:±1%FS/7d (PSA) oxygen production;
Communication: RS232/485 ・Chemical and smelting industries;
79%~99.999% N2:±0.75%FS/7d
・PSA industry Analog output: Free setting ・Detection of oxygen concentration in high temperature furnace;
Response time: T90<30s ・Detection of oxygen concentration in the process of animal
・air separation 0~20mA/4~20mA/0~1V/0~5V/0~10 Explosion-proof and plant culture;
・ambient air oxygen concentration detection V/1~5V analog output mode grade: Exd || CT6 ・Detection of oxygen concentration in the process of animal
・Gas Production Manufacturing Inspection Protection level:IP65 and plant develop;
Dimension: L×W×H=120mm×118mm×62.5mm
・Protection gas detection in semiconductor industry Calibration cycle:one year (recommended) ・Medical and health industry,such as hyperbaric oxygen
chamber,infant incubator,ventilator,anesthesia machine and
・Detection of Gas in Food Production Power supply: 24VDC
other oxygen concentration detection;
・Gas Detection in Petrochemical Process Analyzer power ・Oxygen concentration measurement in families,ships, tunnels
・Oxygen concentration detection in inert gases,etc. consumption: <20VA deep wells,civil air defense projects,urban tunnels,etc.
Communication: RS485/RS232
Switch output: Alarm output:1 set
Relay contact point capacity:24V DC,0.2A
Instructions
Environment ・Ordering Notes:Please refer to page 34 of this sample book.
temperature: -10~+45°C Environment Humidity:<90%RH ・Principle:Please refer to page 46 of this sample book.

47 48
Oxygen transmitter Oxygen transmitter

CI-PC851-2 CI-PC88
Explosion-proof high-content High content oxygen
oxygen analyzer analyzer
The explosion-proof sign of Ex element used in CI-PC88 high content oxygen analyzer uses 3D ion
CI-PC851-2 Explosion-proof high-content oxygen analyz- flow oxygen sensor as measuring unit.After amplifying,
er is Exd II CT6,which is an integral explosion-proof struc- filtering,linearizing correction and standard signal output
ture.It can be used in dangerous environment formed by of sensor signal,the oxygen concentration in nitrogen-ox-
explosive gases and their mixtures of Class II C T6 and below. ygen mixture is calculated by microprocessor,and a set of
The analyzer uses 3D ion flow sensor as measuring analog signals or communications are output.The trans-
unit,which can measure oxygen concentration accurately mitter is suitable for accurate measurement of 10.00%-
in various environments,and provide oxygen concentra- 99.99% oxygen concentration in nitrogen-oxygen mixture.
tion display.

Product Features Technical Specifications Product Features Technical Specifications


・The combination of microcontroller and digital processing Sample gas ・It has the characteristics of intelligence,good stability, Model: CI-PC88
technology can achieve cross-interference resistance, pressure: atmospheric conditions±10% (Gas outlet high reliability and long calibration cycle. Measure range: 10%~95%/99.99% O2
stability and reliability. should be atmospheric conditions) ・The circuit adopts digital signal processing,isolation Accuracy: ±1%FS
・The 3-D ion flow sensor has high precision,good stability Inlet and outlet: 1/4 inch NPT internal thread,standard 6.5 and amplification,frequency cut-off design,and has strong Repeatability: ±0.5%FS
and long service life. hose joint anti-interference ability. Stability: ±0.5%FS/7d
・The latest touch button technology is easy to operate and Sensor life: more than 2 years (normal use)
・Menu lock switch:prevent misoperation and change of Response time: T90<20s (after full preheating)
has a long service life. Instrument life: more than 5 years (normal use)
analyzer parameters from affecting its normal operation; Sensor: 3D Ion flow oxygen sensor
・With infrared remote-control function,the analyzer can be
operated by remote control.
・Communication function:RS232 and RS485 two-way Sensor life: more than 5 years (normal use)
・The explosion-proof design is adopted,and the explosion- Applications communication can be used to communicate directly Instrument life: more than 10 years (normal use)
proof grade reaches Ex II CT6. ・ Air separation industry,such as pressure swing adsorption with computers or other digital communication equip- Weight: about 0.5kg
・Alarm function:When the oxygen concentration deviates (PSA) oxygen production; ment. Power supply: 24VDC,Analyzer power consumption:
from the alarm value,the alarm value can be set arbitrarily ・ Chemical and smelting industries; ・The isolated analog signal output can freely set 0-20mA/ <10VA
within the full range. ・ Detection of oxygen concentration in high temperature furnace; 4-20mA/0-1V/0-5V/0-10V/1-5V analog output mode. Environment
・Communication function:RS485/RS232,only one of the ・ Detection of oxygen concentration in the process of animal ・Simple structure,easy installation and maintenance temperature: -10~55°C,Environment Humidity:<80%RH
analog signals,RS485 and RS232 can be selected. and plant culture;
Sample flow rate: 400~600ml/min
・ Detection of oxygen concentration in the process of animal
and plant develop; Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/
Technical Specifications 1-5V,(You can set the mode freely).
・ Medical and health industry,such as hyperbaric oxygen cham-
Sensor: 3D Ion flow oxygen sensor ber,infant incubator,ventilator,anesthesia machine and other Communication: RS232/RS485
Accuracy: ±1%FS oxygen concentration detection;
Repeatability: ±0.5%FS ・ Oxygen concentration measurement in families,ships,tun-
Stability: ±0.5%FS/7d nels,deep wells,civil air defense projects,urban tunnels,etc. Applications
Response time: T90<20s ・ Air separation industry; Order Information
Display resolution:0.01% ・ Detection of oxygen concentration in oxygen-making
Measuring Order Information equipment of PSA industry;
・ Pressure of the measured gas:positive pressure,
method: on-line ・ The order number: micro pressure or negative pressure;
・ Chemical and smelting industries;
Explosion-proof ・ Output configuration (one of three options,please specify
CI-PC851-2-RX ・ Detection of oxygen concentration in high temperature
grade: Exd || CT6 when ordering):Analog output (standard),RS485 commu-
furnace;
Protection level: IP65 nication,RS232 communication
Power supply: 24VDC Range code:1:10~97.00% ・ Medical and health industry,such as hyperbaric oxygen
・ Sample gas should not contain the following substanc-
Analyzer power chamber,infant incubator,ventilator,anesthesia machine
2:10~99.99% es:
consumption: <20VA and other oxygen concentration detection;
3:97~99.99% 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
Communication: RS485/RS232 ・ Oxygen concentration measurement in families,ships,
CI-PC851-2 explosion - proof high 2.Toxic substances,such as Si,Pb,P,Zn,Sn,As,etc.
Analog output: 1set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ tunnels,deep wells,civil air defense projects,urban
- content oxygen analyzer series 3.Reductive components and hydrocarbons,such as
1-5V,(You can set the mode freely). tunnels,etc.
・ Sample gas should not contain the following substanc- ethanol;
The load:less than 500 Ω
Environment es: 4.Impurities,such as dust.
temperature: -10~+45°C Environment Humidity:<90%RH 1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc.
Switch output: Alarm output:1 set 2.Toxic substances, such as Si,Pb,P,Zn,Sn,As,etc.
Relay contact point capacity:24V DC,0.2A 3.Flux products,such as rosin;
Sample flow rate:400~600ml/min 4.Reductive components,such as ethanol;

49 50
Oxygen transmitter Oxygen transmitter

CI-PC886 CI-PC888/-1
High content Oxygen transmitter
oxygen transmitter
The CI-PC886 oxygen transmitter uses 3DE ion flow The CI-PC888/-1 oxygen transmitter uses 3D ion
oxygen sensor as the measurement unit,after the sensor flow oxygen sensor as the measurement unit,after the
signal amplification,filtering,linearization correction,stan- sensor signal amplification,filtering,linearization correc- CI-PC888
dard signal output and other electrical processing,the tion,standard signal output and other electrical process-
oxygen concentration value in the nitrogen-oxygen mixture ing,the oxygen concentration value in the nitrogen-oxy-
gas is calculated through the microprocessor,and provides gen mixture gas is calculated through the microproces-
analog signal output,communication,alarm switch output sor,and the oxygen concentration information is provided
and other functions.After connecting the display instru- to the external equipment through RS485 communica-
ment,the oxygen concentration value can be displayed tion.After the display instrument is connected,the oxygen
CI-PC888-1
and the instrument can be set. concentration value can be displayed and the transmitter
is set
Product Features Technical Specifications Product Features Applications
・It has the characteristics of intelligence,good stabili- Model: CI-PC886 ・485 Bi-Directional Communication:It can communicate ・ Air separation industry;
ty,high reliability and long calibration period. Measurement directly with computer or other digital communication ・ Detection of oxygen concentration in oxygen making
・The circuit adopts digital signal processing,isolation range: 0~40.00% O2 equipment equipment in PSA industry;
amplification,frequency cut-off design,and has strong ・The 3D ion flow oxygen sensor has good perfor- ・ Chemical and Smelting Industries;
Sensor: 3D ion flow oxygen sensor
anti-interference capability. ・ Oxygen concentration measurement in air supply to
Accuracy: ±1%FS mance,high precision,good stability and fast response.
・Menu lock switch:Preventing misoperation from chang- high temperature furnace;
Repeatability: ±0.5%FS ・long service life:Sensor life can be up to 5 years in
ing transmitter parameters and affecting its normal ・ In the medical and health industry,such as high-pres-
operation normal use sure oxygen storage,baby incubator,respirator,anesthe-
Stability: ±0.5%FS/7d
・Communication Features:RS485 is used to communi- ・Small size,easy to install and use sia machine,and other oxygen concentration detection
Response time: T90<15s
cate directly with computer or other digital communi- ・ The oxygen concentration in the urban tunnels,such as
Sensor life: Greater than 5 years (normal use)
cation equipment home,ship,tunnel,deep well,civil air defense engineer-
・Isolated analog output:0-20mA/4-20mA Analyzer life: Greater than 10 years (normal use) Technical Specifications ing,and urban tunnels,etc.
・Calibration can be initiated by external control signals Power supply: 24VDC,power consumption less than
Measurement
・The invention has simple structure and convenient 10VA range: 0~40.00% O2
installation and maintenance. Ambient 3D ion flow oxygen sensor Order Information
Sensor:
temperature: -10~55°C Accuracy: ±2%FS
project CI-PC888 CI-PC888-1
Environmental Repeatability: ±1%FS
measurement
humidity: <85%RH Stability: ±1%FS/7d 0-40.00% O2 0-25.00% O2
range
Analog output: Free setting4-20mA/0-20mA mode Response time: T90<30s
output mode RS485 TTL/RS485
Communication: RS485 Sensor life: Greater than 5 years (normal use) mounting
Applications Transmitter power hole size
30mm(2×Φ3.5) 25mm(2×Φ3.5)
External input: A Set of 9~28VDC External Control
・Air separation industry consumption: 12~24VDC outline size
Signals
・Detection of Oxygen Concentration in Oxygen Making Ambient
Equipment in PSA Industry temperature: Less than 5VA
・Chemical and Smelting Industries Environmental
・Measurement of Oxygen Concentration in High Tempera- humidity: 0~45°C <85%RH
ture Furnace Order Information Feature
・Medical and health services,such as high-pressure The following substances cannot be contained in the test configuration: RS485 Communication (Optional
oxygen storage,baby incubator,respirator,anesthesia Display Header)
environment :
machine,and other oxygen concentrations; 1.Corrosive gases such as HF,Cl2,HCl,SO2,H2S,etc.
・The oxygen concentration in the urban tunnels,such as Cable sensor 3DE01 3DE05
2.toxic substances,such as Si,Pb,P,Zn,Sn,As; Colour Function
home,ship,tunnel,deep well,civil air defense engineer- Identification
3.Reducing components,hydrocarbons,such as ethanol
ing,and urban tunnels,etc. 24V+ Blue 12~24VDCPower supply anode The test environment shall not contain the following
4.Impurities,such as dust.
24V- Black 12~24VDCPower supply cathode substances:
1.Corrosive gases,such as HF,Cl2,HCl,SO2,H2S,etc;
485A Brown RS485 Communication A Terminal 2.Toxic substances,such as Si,Pb,P,Zn,Sn,as,etc;
485B White RS485 Communication B Terminal 3.Reducing components,hydrocarbons,such as ethanol;
4.Impurities,such as dust.

51 52
Flue oxygen analyzer Flue oxygen analyzer

CI-PC182-1/2 CI-PC191/-1
Flue oxygen analyzer Series direct inserted oxygen
analyzer for flue gas
CI-PC182-1/2 Flue Oxygen Analyzer is an oxygen CI-PC191/-1 series is a special oxygen analyzer
CI-PC182-1
content detector developed by our company for the designed for integration.The analyzer is mainly composed
detection of oxygen content in flue and other harsh of a head and a probe.The head is made up of a micropro-
environments.The CI-PC182 analyzer is designed in one- cessor,and the probe is made up of a frequency conver-
piece,and the CI-PC182-1/2 analyzer is designed in sion ion flow oxygen sensor. It has the characteristics of
two-piece.It is based on microprocessor and frequency intelligence and high precision,and is suitable for the
conversion ion oxygen sensor. accurate measurement of oxygen concentration in
CI-PC182-2 0-25.00% nitrogen-oxygen mixture in various industries
CI-PC182 and environments.

Product Features Technical Specifications Product Features Technical Specifications


・The characteristics of intelligence,good stability,high sensor life : Greater than 2 years (normal use) ・The characteristics of intelligence,good stability,high temperature of
reliability,long calibration period,etc. Display instrument life: Greater than 5 years (normal use) reliability,long calibration period,etc probe: CI-PC191 is 0~500°C,CI-PC191-1 is
・Wide use:The probe can be used safely in the tempera- Surface ambient ・Menu Lock feature:It can prevent the error operation to 0~180°C
ture range of 0-500°C. temperature : -10~50°C modify the analyzer parameters and affect its normal Header size: L×W×H=158mm×158mm×99.5mm
・Plug-in probe:The probe works in the environment to be operation Probe insertion
ambient temperature: 0~500°C
measured,reflecting the true and reliable oxygen ・Temperature Alarm and Temperature Protection Fea- depth: 600mm,800mm,1000mm,1200mm,1500m
environmental
content,fast response speed and low failure rate tures:When the temperature inside the head exceeds m,1800mm Can be customized according
humidity: <90%RH 60°C,the temperature alarm will be sent out.When the
・Carried out.The visible window is made of tempered measurement method: Direct insertion to user needs
temperature exceeds 70°C,the heating voltage of the Sensor warm up
glass,all the test pieces and electric modules are in the Display Instrumentation sensor will be reduced and the temperature protection
metal shell,and the sealing performance is very good,and time: About 2 minutes.
Installation: Wall-mountedflange installation of the analyzer will be carried out.
the analyzer can adapt to the bad environment outside Probe tube outer
Probe installation: flange installation ・One-Shot,One-Throw Alarm Function (Optional)
wind and rain structure diameter: Φ40mm
・Probe insertion depth can be customized according to
・Easy to install and use:DN25 standard flange is used to user condition
install the probe.It is compact and convenient to install ・The probe can be accurately tested in environments up Applications
and use Applications to 500°C ・Determination of Oxygen Concentration in Flue Gas
・Determination of Residual Oxygen Concentration in ・Measurement of Oxygen Concentration in High Tempera-
Technical Specifications Flue Duct Technical Specifications ture Furnace
・Measurement of Oxygen Concentration in High Tempera- ・Monitoring and control of oxygen concentrations in
Model: CI-PC182 Integrated band display Model: CI-PC191 (basic type)
ture Furnace large,medium,small and small boilers and heating furnaces
・The detection of oxygen concentration in the process CI-PC191-1 (heat tracing type)
CI-PC182-1 Split type with secondary instru- (energy-generating boilers:heavy oil,natural gas or coal)
of animal and plant culture,vegetable and food process- Measurement
ment ・Various industrial furnaces (smelting flow/steel manu-
ing storage; range: 0~25.00% O2
CI-PC182-2 Explosion-proof split type with facturing heating furnaces,coal furnaces,black liquid
・Ships,underground command centers,tunnels,deep wells,- Accuracy: 0.01%~0.1%: ±3%FS
secondary instrument regeneration boilers);other applications may not be
civil air defense engineering,urban tunnels,oxygen concen- 0.01%~1%: ±3%FS
Measurement applicable to corrosive gases such as ammonia and
tration detection,etc. 0.01%~25%: ±2%FS
range: 0~25.00% O2 Repeatability: 0.01%~0.1%: ±1.5%FS chlorine,etc.,and contact Changai Company;
Sensor principle:Frequency conversion ion flow oxygen sensor 0.01%~1%: ±1.5%FS ・The detection of oxygen concentration in the process of
Accuracy: ±2%FS 0.01%~25%: ±1%FS animal and plant culture,vegetable and food processing
Repeatability: ±1%FS storage;
Order Information Stability: ±1% FS/7d
・Ships,underground command centers,tunnels,deep wells,-
Stability: ±1%FS/7d Response time: T90<30s (after full preheating)
Response time: T90<20s (Fully Preheated) ・ 4-20mA,0-20mA,RS485 three-select,users must explain Power supply: 24VDC,7A civil air defense engineering,urban tunnels,oxygen concen-
Analyzer power to the supplier when ordering; Relay contact tration detection,etc
consumption: <20VA ・ The following substances cannot be contained in the capacity: 24VDC,0.2A (optional alarm)
Function: RS485 (optional) is used to communicate test environment: Communication: RS232 (Standard)/RS485(optional)
Order Information
with computer or other digital communica- 1.Corrosive gases such as HF,Cl2,HCl,SO2,H2S,etc. Sensor life: More than 2 years (normal use)
tion equipment directly 2.Toxic substances such as Si,Pb,P,Zn,Sn,As,etc. Sensor model: GYB4.9 The following substances cannot be contained in the
Analog output Ambient test environment
3.Reducing components,hydrocarbons,such as ethanol
signal: 4-20mA/0-20mA (settable) temperature of Corrosive gases such as HF,Cl2,HCl,SO2,H2S,etc.
400mm,600mm(Standard),1500mm(Or meter: -10~60°C Toxic substances such as Si,Pb,P,Zn,Sn,As,etc.
Ambient Reducing components,hydrocarbons,such as ethanol
customize other sizes)

53 54
Flue oxygen analyzer Dew point meter

CI-PC192 CI-PC30
Flue oxygen analysis system Dew point analyzer

CI-PC192 oxygen analysis system takes micropro- CI-PC30 analyzer uses ultra-thin alumina capacitive
cessor as the core and variable frequency ion current oxygen sensor as measuring unit and combines microcontroller
sensor as the measurement unit.It has the characteris- with digital processing technology.It has complete self-di-
tics of intelligence and high precision.It is suitable for the agnosis function and monitors the working state of the
accurate measurement of 0-25.00% oxygen concentra- instrument at any time.The analyzer has the advantages
tion in nitrogen oxygen mixture in various industries and of intelligence,stability,reliability and long service life.It is
environments. suitable for dew point detection of mixed gases in various
industries and environments.

Product Features Technical Specifications Product Features Technical Specifications


・It has the characteristics of intelligence,good stability, Sensor life: More than 2 years (normal use) ・With microprocessor as the core and ultra-thin alumina External control:quantity:1 set
high reliability and long calibration cycle; System ambient capacitive sensor as the measuring unit,it has the control signals:9~28VDC
・Menu lock switch:prevent misoperation from affecting temperature: -10~50°C characteristics of intelligence,stability,high precision purpose:can be used to control the pump
the analysis system; Ambient temperature and long calibration period. switch (optional)
・Automatic calibration function:automatic calibration of ・The dew point value and volume fraction are displayed Environment
of probe: Probe material SUS310S 800°C
the instrument;
Probe material SIC 1400°C at the same time to meet the different needs of users. temperature: 0~+45°C Environment Humidity:<80%RH
・Automatic back purging function:automatically complete
Measurement ・Menu lock switch:prevent misoperation and change of Sample gas
the instrument purging according to the instrument
settings; method: Ejection type analyzer parameters from affecting its normal opera- pressure: atmospheric conditions±10% (Gas outlet
・Alarm function:when the oxygen concentration deviates Installation mode of tion; should be atmospheric conditions)
from the alarm value or the operation is wrong,an alarm analysis system: Wall mounted ・Alarm function:When the dew point deviates from the Case size: L×W×H=310mm×275mm×190mm
will be given; Installation alarm value,the alarm value can be set arbitrarily in the Installation size:L×W=225mm×180mm(Rectangular hole)
・Communication function:adopt RS485/RS232 two-way dimension of L×W=560mm×360mm(4×Φ8) full range. Fixed hole size: L×W=252mm×170mm(Φ6×4 Bolt hole)
communication,can communicate with computer or analysis system: 400mm,600mm,800mm,1000mm,1
other digital communication equipment directly; Probe insertion depth:200mm,1500mm,1800mm,etc(can
・Isolated analog signal output,0-20mA can be set freely be customized according to users' Applications
through the menu/4-20mA/0-1v/0-5V/0-10V/1-5Vana- Technical Specifications
needs)
log output mode; ・ Gas humidity detection in metallurgical industry;
・Easy to install and maintain. Sensor: ultra-thin alumina capacitive sensor ・ Gas humidity detection in food production and packag-
Measure range: -60°C~+20°C (Basic type) ing process;
Applications -80°C~+20°C (Standard type) ・ Gas humidity detection in petrochemical process;
・ Detection of oxygen concentration in flue; -100°C~+20°C (Extended type) ・ Gas humidity detection in power electronics and
・ Detection of oxygen concentration in high tempera- Accuracy: ±3°C(-80~-60°C) machinery manufacturing industries, etc.
Technical Specifications ±2°C(-60~+20°C)
ture furnace; ・ Humidity monitoring during drying agent manufactur-
Measurement range: 0.01%~25.00% O2 ・ Ship,underground command center,tunnel,deep well,civil Repeatability: ±0.5°C
ing and plastic substrate drying.
Resolving power: 0.01% air defense engineering,urban tunnel oxygen concen- Zero drift: ±1%FS/7d
Accuracy: 0.01%~0.1%: ±3%FS tration detection,etc. Range drift: ±1%FS/7d
0.01%~1%: ±3%FS Response time: At the temperature of +20°C and pressure
0.01%~25%: ±2%FS of 1bar,the range reaches 63%[90%]
Order Information
Repeatability: 0.01%~0.1%: ±1.5%FS -60→-20°C Td 5s[10s]
0.01%~1%: ±1.5%FS Order Information -20→-60°C Td 45s[10min] ・ Pneumatic connection mode:
0.01%~25%: ±1%FS Power supply: 85~264VAC,50/60Hz A,Φ6 hose (standard);
The following substances cannot be contained in the test
Stability: ±1% FS/7d Analyzer power B,connecting by using 1/4-Φ6 stainless steel cutting
environment
Response time: T90<30s(after full preheating) consumption: <35VA ferrule;
Corrosive gases such as HF,Cl2,HCl,SO2,H2S,etc.
Sensor: Variable frequency ion current Toxic substances such as Si,Pb,P,Zn,Sn,As,etc. Communication:RS485(standard)/ RS232(optional) C,connecting by using 1/8-Φ3 stainless steel cutting
oxygen sensor Reducing components,hydrocarbons,such as ethanol Alarm output: 1set ferrule;
Relay contact Relay contact point capacity:24V DC,0.2A ・ Under the standard condition,the sensor is not suitable
capacity: 24VDC,0.2A Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ for natural gas operation.When ordering,the supplier
Power supply: 85~264VAC,50/60Hz 1-5V (You can set the mode freely). should be informed whether the sample gas contains
Communication: RS485(standard)/RS232(optional) The load:less than 500Ω natural gas or not.

55 56
Dew point meter Dew point meter

CI-PC31 CI-PC35/-1
Dew point analyzer Explosion-proof dew point
analyzer
The CI-PC31 dew point analyzer takes the ultra-thin The case of CI-PC35/-1 explosion-proof dew point analyzer
alumina capacitive sensor as the measuring unit,the micro- is designed with explosion-proof design.The explosion-proof
controller as the core,and adopts the digital processing sign of Ex element is Exd II C,which is the whole flameproof
technology,so that the analyzer has the advantages of structure.It can be used in dangerous environment of zone 1
intelligence,high precision,good stability and long calibra- and zone 2 formed by explosive gases and their mixtures of
Class II C T6 and below.The analyzer can accurately measure
tion cycle.The analyzer adopts 19-inch standard profile
humidity in various environments.The instrument adopts CI-PC35-1
case,which is beautiful in appearance, easy to install and
digital processing technology,and its calibration,lineariza-
use.It is widely used in various industrial systems to tion,switch output control,current/voltage output,parameter
realize real-time monitoring of gas humidity and display setting and other functions all use digital processing technology. CI-PC35
gas dew point value.
Product Features Technical Specifications Product Features Technical Specifications
・With microprocessor as the core and ultra-thin alumina The load:less than 500 Ω ・With microprocessor as the core,it has good long-term 1-5V,(You can set the mode freely).
capacitive sensor as the measuring unit,it has the charac- External control:quantity:1 set stability and high reliability. The load:less than 500 Ω
teristics of intelligence,stability,high precision and long control signals:9~28VDC ・Ultrathin alumina capacitive sensor is used as measur- Sample flow rate: 3~5L/min
calibration period. Environment ing unit with high accuracy and long calibration period. Sample gas
・Menu lock switch:prevent misoperation and change of Temperature: 0~45℃ Environment Humidity:<80%RH ・Dew point value and volume fraction are displayed at pressure: atmospheric conditions±10% (Gas
analyzer parameters from affecting its normal opera- Sample flow the same time to meet different needs of users outlet should be atmospheric conditions)
tion; rate: 2~3L/min ・Menu lock switch:prevent misoperation and change of Inlet and outlet: Gas interface:1/4-inch NPT internal thread,
・Alarm function:When the dew point deviates from the Case size: L×W×D=483mm×177mm×300mm analyzer parameters from affecting its normal opera- stainless steel material (standard 1/4-6
alarm value,the alarm value can be set arbitrarily in the Installation: dial type installation tion; card-plastic joint)
full range. Installation size:L×W=445mm×180mm(Rectangular hole) ・Alarm function:When the dew point deviates from the Sensor life: more than 2 years (normal use)
Fixed hole size: L×W=465mm×101.5mm(Φ6×4 Bolt hole) alarm value,the alarm value can be set arbitrarily in the Instrument life: more than 5 years (normal use)
full range. Measuring method:wall-mounted
Technical Specifications CI-PC35: L×W×H=300×200×175mm
Measure range: -60°C~+20°C (Basic type)
Applications Flow meter:Selection
-80°C~+20°C (Standard type) ・Gas humidity detection in metallurgical industry; Technical Specifications CI-PC35-1: L×W×H=375×315×179mm
-100°C~+20°C (Extended type) ・Gas humidity detection in food production and packag- Sensor: ultra-thin alumina capacitive sensor Level of explosion-proof:Exd || CT6 (certi-
Sensor: ultra-thin alumina capacitive sensor ing process; Measure range: -60~+20°C(Basic type) fication)
Accuracy: ±3°C(-80~-60°C) ・Gas humidity detection in petrochemical process;
-80~+20°C(Standard type)
±2°C(-60~+20°C) ・Gas humidity detection in power electronics and machin-
-100~+20°C(Extended type)
ery manufacturing industries,etc. Applications
Repeatability: ±0.5°C Accuracy: ±3°C(-80~-60°C)
・Humidity monitoring during drying agent manufactur-
Zero drift: ±1%FS/7d ±2°C(-60~+20°C) ・Gas humidity detection in metallurgical industry;
ing and plastic substrate drying.
Range drift: ±1%FS/7d Repeatability: ±0.5°C ・Gas humidity detection in food production and packag-
Response time: At the temperature of +20°C and pressure Zero drift: ±1%FS/7d ing process;
of 1bar,the range reaches 63% [90%] Order Information Range drift: ±1%FS/7d ・Gas humidity detection in petrochemical process;
-60→-20°C Td 5S[10S] ・ Pressure of the measured gas:positive pressure, Response time: T90<30s ・Gas humidity detection in power electronics and
-20→-60°C Td 45S[10min] micro pressure or negative pressure; Protection level:IP64 machinery manufacturing industries,etc.
Power supply: 85~264VAC,50/60Hz ・ Measuring range:-100°C/-80°C/-60°C~+20°C; Calibration cycle:one year(recommended) ・Humidity monitoring during drying agent manufactur-
Analyzer power ・ Pneumatic connection mode: Power supply: 24VDC ing and plastic substrate drying.
consumption: <20VA A,Φ6 hose (standard); Analyzer power
Communication: RS485(standard)/RS232(optional) B,connecting by using 1/4-Φ6 stainless steel cutting consumption: <20VA
Alarm output: 2 sets (one set of concentration alarm,one ferrule; Communication: RS485(standard)/RS232(optional) Order Information
set of status alarm) C,connecting by using 1/8-Φ3 stainless steel cutting Environment
ferrule; ・The sensor in standard configuration of the analyzer
Relay contact point capacity:24V DC,0.2A temperature: 0~45°C
・ The sensor in standard configuration of the analyzer is not suitable for humidity detection in natural gas
Sample gas Environment
is not suitable for humidity detection in natural gas environment.If the working condition is natural gas
pressure: atmospheric conditions±10% (Gas outlet humidity: <90%RH
environment.If the working condition is natural gas environment,the user should explain to the supplier
should be atmospheric conditions) Alarm output: 1 set
environment,the user should explain to the supplier when ordering.
Analog output: 2sets,4-20mA/0-20mA/0-1V/0-5V/0-10V/ when ordering. Relay contact point capacity:24V DC,0.2A
・Whether to equip pumps and flowmeters.
1-5V,(You can set the mode freely). ・ Whether to equip pumps and flowmeters. Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/

57 58
Dew point meter Dew point meter

CI-PC35/-2 CI-PC36
Explosion-proof dew point Dew point analyzer
analyzer
The case of CI-PC35/-2 explosion-proof dew point analyzer CI-PC36 dew point analyzer is an intelligent dew point
is designed with explosion-proof design.The explosion-proof analyzer with microprocessor as its core and ultra-thin
sign of Ex element is Exd II C,which is the whole flameproof alumina capacitive sensor as its measuring unit.It has the
structure.It can be used in dangerous environment of zone 1 characteristics of high precision,good stability,compre-
and zone 2 formed by explosive gases and their mixtures of
hensive function and long service life.It can measure dew
Class II C T6 and below.The analyzer uses ultra-thin alumina
point accurately in various environments.
capacitive sensor as measuring unit,which can accurately
measure dew point in various environments,provide users with
dew point temperature and humidity volume ratio display,and
output dew point signal through analog signal,RS232 or RS485.

Product Features Technical Specifications Product Features Technical Specifications


・The combination of microcontroller and digital processing Protection level: IP65 ・With microprocessor as the core,it has the characteris- External control
technology can achieve cross-interference resistance,stabili- Calibration cycle: one year (recommended) tics of intelligence,good stability and high reliability. signal: 1 set,control signal:9~28VDC (optional)
ty and reliability. Power supply: 24VDC Ultrathin alumina capacitive sensor is used as measur- Analog output: Standard configuration set of 4-20mA,
・Ultrathin alumina capacitive sensor is used as measuring Analyzer power ・ing unit with high accuracy and long calibration period. 0-20mA and 0-10V can be set by menu
unit with high accuracy and long calibration period. Menu lock switch:prevent misoperation and change of Communication: RS485(standard)/RS232(optional)
consumption: <20VA
・The 128*640 LED screen is used as a man-machine interac- Alarm output: 2 sets
Communication: RS485/RS232 analyzer parameters from affecting its normal opera-
tive display window,which is intuitive and rich in content.
Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ ・tion; Relay contact
・Synchronized display of dew point value and volume ratio
to meet the different needs of users; 1-5V,(You can set the mode freely). Alarm function:When the dew point deviates from the point capacity: 24VDC,0.2A
・The latest touch button technology is easy to operate and The load:less than 500 Ω alarm value,the alarm will be issued. Inlet and outlet: 1/4 inch NPT internal thread,standard
has a long service life. Switch output: Alarm output:1 set ・Communication function:RS485 (standard) and RS232 6.5 hose joint
・With infrared remote-control function,the analyzer can be Relay contact point capacity:24V DC,0.2A (optional) two-way communication function can be Instrument size: W×H×D=144m×144mm×251mm
operated by remote control. Environment ・used to communicate directly with computer or other Installation hole
・Menu lock switch:prevent misoperation and change of temperature: -10~+45°C digital communication equipment. size of instrument: L×W=136mm×136mm
analyzer parameters from affecting its normal operation; Environment
・The explosion-proof design is adopted,and the explosion- humidity: <90%RH
proof grade reaches Ex II CT6.
Sample flow rate: 3~5L/min Applications
・Alarm function:When the dew point deviates from the alarm
Sample gas ・ Air separation;
value,the alarm value can be set arbitrarily in the full range. Technical Specifications
pressure: atmospheric conditions±10% (Gas outlet ・ Gas manufacturing inspection;
should be atmospheric conditions) Measure range: Basic type:-60~+20°C ・ Gas humidity detection in metallurgical and smelting
Inlet and outlet: 1/4 inch NPT internal thread,standard 6.5 Standard type:-80~+20°C industries;
hose joint Extended type:-100~+20°C ・ Gas humidity detection in food production process;
Technical Specifications Sensor life: more than 2 years (normal use) Accuracy: ±3°C(-80~-60°C) ・ Gas humidity detection in petrochemical process;
Measure range: -60°C~+20°C(Basic type) Instrument life: more than 5 years (normal use) ±2°C(-60~+20°C) ・ Gas humidity detection in machinery manufacturing
-80°C~+20°C(Standard type) Repeatability: ±0.5°C industry,etc.
-100°C~+20°C(Extended type) Zero drift: ±1% FS/7d
Sensor: ultra-thin alumina capacitive sensor Applications Range drift: ±1% FS/7d
Accuracy: ±3°C(-80~-60°C) Response time: At the temperature of +20°C and pressure
・ Dew point measurement in lithium battery workshop; Order Information
±2°C(-60~+20°C) of 1bar,the range reaches 63% [90%]
・ Air purification and clean room; ・ Pressure of the measured gas:positive pressure, micro
Repeatability: ±0.5°C -60→-20°C Td 5s[10s]
・ Compressed air drying; pressure or negative pressure;
Zero drift: ±1%FS/7d -20→-60°C Td 45s[10min]
・ Dew point detection of SF6 circuit breaker in power ・ Pneumatic connection mode:A,Φ6 hose (standard);B,
Range drift: ±1%FS/7d Power supply: 85~264VA,50/60Hz
system; connecting by using 1/4-Φ6 stainless steel cutting
Response time: At the temperature of+20°C and pressure Environment
・ Drying industry; ferrule;C,connecting by using 1/8-Φ3 stainless steel
of 1bar,the range reaches 63% [90%] temperature: 0~45°C Environment Humidity:<90%RH
・ Food processing; cutting ferrule;
-60→-20°C Td 5s[10s] Sample ・ Filter:GF2800,AF2000;
・ Drying of plastic substrates;
-20→-60°C Td 45s[10min] temperature: 0~50°C ・ Under the standard condition,the sensor is not suitable
・ Power gas quality control;
Display resolution:0.1°C Sample gas for natural gas operation.When ordering,the supplier
・ Nitrogen production and purity maintenance;
Explosion-proof pressure: atmospheric conditions±10% (Gas outlet should be informed whether the sample gas contains
・ Extremely dry conditions are required.
grade: Exd || CT6 should be atmospheric conditions) natural gas or not.

59 60
Dew point meter Dew point meter

GEN-25 CI-TM
Portable dew point Series dew point transmitter
analyzer
GEN-25 analyzer is a dew point detection device with A new polymer film sensor technology is used.Polymer
micro-controller technology as its core and ultra-thin film sensors have the advantages of anti-pollution,anti-con-
densation,good linearity and high humidity signal.But the
alumina capacitive sensor as its measuring unit.It adopts
common polymer film sensors have a huge weakness,that
digital processing technology,including zero/range calibra- is,weak signal quantity and poor stability in low humidi-
tion,linearization processing,switch output control,cur- ty.Therefore,few polymer film sensors are used to measure
rent/voltage output,parameter setting and other functions,all ultra-low dew point on the market.Depending on this new
using digital processing technology.The analyzer has the material,the ultra-low humidity signal quantity and stability of
polymer film sensor are improved to the extreme level,which
functions of alarm output,communication and analog signal
makes it have the advantages of high humidity response of
output. general polymer film sensor and unprecedented low humidi-
ty response level.
Product Features Technical Specifications Product Features Technical Specifications
・The dew point value,menu,data and working state of Weight: net weight about 4 kg,packing about 5 kg ・The new polymer film sensor technology,which improves Current output: 4...20 mA(3 line) range can be changed
the instrument are displayed by 128*64 LCD window, Charging power the signal and stability to the extreme,ensures the high Current
which is intuitive and rich in content supply: 85~264VAC,50/60Hz precision measurement of the whole range. output resolution: 0.002 mA
・Long-term stability,high reliability,high accuracy and Power waste: <20VA ・The automatic heating calibration function provides Current output
long calibration cycle Communication: RS485(Standard Matching)/RS232 (Option- ultra-fast response speed and excellent long-term stabil- temperature drift: 0.01% of span/°C
・The dew point value and volume fraction are displayed Current output load: Maximum 500Ω
al Matching) ity.
simultaneously (ppm/V) to meet the different needs of Digital output: RS485
Switch output: 1 group,relay contact capacity:24VDC,0.2A ・Anti-condensation,anti-particulate pollution,oil vapor and
users. Connector: 5-pin M12
Analog output chemicals Automatic heating: 16...30 V/250 mA
・Built-in large capacity lithium battery,standby time can signal: 1group,4-20mA/0-20mA/0-1V/0-5V/0-10V ・Excellent temperature drift compensation ensures high Normal
be more than 48 hours /1-5V,freely set mode precision measurement in a wide temperature range. measurements: 16...30V/30 mA+4-20mA Current output
・Menu Lock-in Switch:Prevent misoperation from chang-
Load:less than 500Ω ・Super high signal resolution and excellent anti-jamming Working
ing analyzer’s parameters and affecting its normal opera-
Connection port: DB-15 Female capability are provided based on powerful micropro- temperature: -20...+70 °C
tion
Environmental cessors and robust circuit design. Storage
・Alarm function:When the dew point deviates from the temperature: -30...+80 °C
temperature: 0~45°C ・IP65 protection level,can provide good protection even
alarm value,the alarm value can be set arbitrarily within Relative humidity: 0...95 %RH
Environmental humidity:less than 80% RH in harsh environment;
the full range. Sample flow rate: >1 L/min
・Communication function:RS485 (standard matching)/ Sample pressure:atmospheric pressure +10%(outlet should ・Provide comprehensive sensor settings,data transmis-
Pressure: 0...50 bar
RS232 (optional matching) be atmospheric pressure) sion and maintenance functions through standard RS485
Protection level: IP65
・Isolated analog signal output,0-20mA/4-20mA/0-1V/0-5V/ Inlet and outlet: 1/4 inch NPT internal thread,stainless steel interface and simple,easy-to-use and powerful service
Mechanical parts
0-10V/1-5V analog output mode can be set material (standard) 1/4-6 card-plastic joint) software. Connection: ISO G 1/2”
Instrument size:L×W×D=258.5mm×161.8mm×244mm Stainless steel
Packing: Carton,L×W×H=400mm×400mm×300mm mesh filter: filtration grade<30um
Technical Specifications EMC: compliance with IEC 61326-1

Dew point
Technical Specifications measurement range: -60°C...+60°Ctd CI-TM01 Applications
Scope of -60°C...+20°Ctd CI-TM02
-80°C...+20°Ctd CI-TM03 ・Air separation,gas production and manufacturing inspec-
measurement: -60°C~+20°C (basic type)
-80°C~+20°C (Standard) Applications -100°C...+20°Ctd CI-TM04 tion;
Temperature ・Gas humidity detection in food production process;
-100°C~+20°C (extended type) Manufacturers and users of petroleum,chemical and
measurement range:-40...+100°C Range can be customized ・Gas humidity detection in petrochemical process,mois-
Sensor: Ultrathin Alumina Capacitance Sensor desiccant,dew point detection of SF6 in power system,
Dew point accuracy: ±3°C(-80~-60°C) ture content detection in various gases in lithium battery
Accuracy: ±3°C(-80~-60°C) measurement of trace moisture in gases of semiconduc- ±2°C(-60~+20°C) manufacturing,drying equipment,electronic power,me-
±2°C(-60~+20°C) tor manufacturing,drying,food industry,plastic substrate Temperature chanical manufacturing and other industries.
Repeatability: ±0.5°C drying,mechanical manufacturing and air separation indus- accuracy: 0...+50°C ±0.3°C(Standard)
Zero drift: ±1%FS/7d tries. -40...0°C and+50...+100 °C
Range drift: ±1%FS/7d ±0.5°C(standard) Temperature Instructions
Response time: Reach the range of 63% [90%] under the accuracy can be customized Working Principle:please see page 64 of this sample
condition of 20°Cand pressure 1 bar.-60 Response time: 63% [90%],20°C,1bar(gauge),4L/min
book.
→-20°C Td 5s[10s] -20→-60°C Td 45s[10min] Dew point sensor: -80 ->-30 °Ctd 20 seconds[40seconds]
-30 ->-70 °Ctd 5 minutes [20minutes]

61 62
Dew point meter Dew point meter

CI-QM CI-BM05
Series dew point sensor Micro-water and
temperature transmitter in oil
The QCM sensor combines with the newly developed humidi- BM05 oil-water transmitter is a pioneer product of
ty sensitive material,which can measure the humidity at the low oil-water monitoring,which adopts the principle of "capac-
ppb level steadily. The long-term stability of the sensor is improved
itance measurement of water",combines high-precision
by the automatic anti-pollution compensation technology.Excel-
lent sensor circuit design can automatically compensate circuit data processing methods and integrates the precise
drift caused by temperature, pollution and aging, provide long-term measurement technology of "Chang Ai" measurement
reliable high-precision measurement,combined with the ultra-high and control.It can quickly and accurately measure the trace
stability of QCM sensor technology, the period of re-calibration can moisture in transformer oil and lubricating oil used in
be extended to more than two years.Innovative temperature
compensation algorithm and multi-point temperature compensa-
industrial field.The water activity aw,micro water ppm and
tion calibration before leaving the factory greatly improve the temperature T in oil were measured directly.By upgrading
temperature drift of the sensor and ensure high precision measure- and loading specific oil parameters,the water content of
ment in a wide temperature range. multi-class oil can be measured.
Product Features Technical Specifications Product Features Technical Specifications
・The new QCM sensor technology can measure humidi- Current output ・It can be used for continuous on-line measurement of resolution: 0.002mA
ty as low as-110°C td. resolution: 0.002 mA micro-water in oil. Temperature drift
・The accuracy measurement is as high as +/-2°C td. Temperature drift ・The PPM (w) value in oil can be calculated by measur- of current output: 0.01% of span/°C
・Innovative online anti-pollution technology; of current output: 0.01% of span/C ing water activity. Current Output
・Super-fast response speed and excellent long-term stabili- Current output ・Measure transformer oil,hydraulic oil,lubricating oil,engine Load: Maximum 500Ω
ty; oil,diesel oil; Digital output: RS485
load: maximum 500 ohm
・Multi-point temperature compensation calibration before ・Excellent temperature and pressure resistance and fast Connector: 5-pin M12
Digital output: RS485
leaving the factory; response speed; Normal
・Excellent anti-interference ability; Connector: 5-pin M12
・Innovative temperature compensation algorithm and measurement: 16...30V/30 mA+4-20mA current output
・IP65 protection level,even in harsh environment can Normal Working
measurement: 16…30V/30 mA + 4-20mA Current multi-point temperature compensation calibration before
provide good protection; temperature: -20...+70°C
output leaving the factory;
・Through the standard RS485 interface and powerful storage
・Excellent anti-interference ability;
service software,it provides comprehensive sensor Working temperature: -40...+80°C
settings,data transmission,software upgrade and ・IP65 protection level,can also provide good protection
temperature: -20…+70°C relative humidity: 0...95%RH
maintenance functions. even in harsh environment; Pressure: 0...50bar
Storage
・Through the standard RS485 interface and powerful Shell: stainless steel
temperature: -30…+80°C
service software,it provides comprehensive sensor Protection Level: IP65
Relative humidity: 0…95 %RH
settings,data transmission,software upgrade and mainte- Mechanical Parts
Sample flow rate: >1 L/min nance functions;
Technical Specifications pressure: 0…16 bar
Connection: ISO G 1/2”
・supports the MODBUS RTU protocol. EMC: IEC 61326-1
Dew point -80…+20°Ctd (standard type) CI-QM01 Shell: stainless steel
measurement -110…+20°Ctd (Extended Type) CI-QM02 Protection Level: IP65
range: Mechanical Parts Technical Specifications Principle
Temperature Connection: ISO G 1/2”
measurement Stainless steel Measurement range
range: -40…+100°C mesh filter: filter grade 30-45 um of water activity: 0...1aw
Oil temperature
EMC: IEC 61326-1
Dew point measurement
上电极
Upper electrode
range: -40...+100°C
accuracy: -20…-80°C +/- 2°Ctd 聚合物层
Polymer layer
Water activity
(Air or Nitrogen)-80… -110°C +/- 3°Ctd 下电极
Lower electrode

accuracy: 0...0.9 +/-0.02


Temperature Applications 0.9...1.0 +/-0.03
传感器基座
Sensor base

accuracy: 0…+50°C +/-0.3°C(Standard) ・Air separation,gas production and manufacturing inspec- 0...+50°C +/-0.3°C(Standard)
-40…0°C and +50…+100°C +/-0.5°C(Standard) tion; Temperature
Temperature accuracy requirements can be ・Gas humidity detection in food production process; accuracy: -40...0°C and +50...+100°C +/-0.5°C Sensor technology is a capacitive sensor based on a hydro-
customized ・Gas humidity detection in petrochemical process,mois- (Standard) philic polymer film.The sensor measures water vapor around
Response time: 63% [90%],20C,1bar (gauge),4L/min: ture content detection in various gases in lithium battery temperature accuracy requirements can be air or gas.Water molecules pass through the permeable
-80 -> -30°Ctd 20s [40s] customized upper electrode,diffuse to the polymer layer and change
manufacturing,drying equipment,electronic power,me-
-30 -> -70°Ctd 5min [20min] Dry to wet (typical the capacitance of the sensor.
chanical manufacturing and other industries.
Current output: 4…20 mA(3 lines) (range can be changed) value): <1min
Current output: 4...20mA (3 lines) (range can be changed)
Current output

63 64
Dew point meter Dew point meter

CI-BM146/147 GNL-STM3-DP
dew point and pressure transfer Dew point analysis system
for compressed air
BM146/147 dew point and pressure transmitter GNL-STM3-DP dew-point analysis system is a
make the monitoring of compressed air simpler.Dew high-precision online dew-point meter developed by our
point and pressure can be measured at the same time.It is company.The instrument adopts an imported thin-film
an ideal choice for pressure monitoring of compressed capacitive humidity sensor,combined with a single-chip
air.It uses all-new polymer film sensor technology.Depend-
microcomputer control technology,and has the character-
ing on this new material,the ultra-low humidity signal and
istics of high measurement accuracy and easy operation.
stability of the polymer film sensor are improved to the
extreme level.Combined with the Auto-heating function It has two programmable alarm values,two sets of alarm
and the ultra-high stability of the polymer film sensor outputs,one programmable current output (4-20mADC)
technology,the re-calibration period can be extended to and one RS232 data communication.
more than two years.
Product Features Technical Specifications Product Features Technical Specifications
・New polymer film sensor technology and pressure accuracy: 0...+50°C +/-0.3°C (Standard) ・The sensor has the characteristics of fast response Test
sensor based on MEMS; -40...0°C and +50...+100 °C speed and high measurement precision.The chip of the environmental
・Dew point and on-line pressure can be monitored +/-0.5°C (Standard) Temperature sensor itself has the function of automatic heating humidity: <90%RH
simultaneously (absolute pressure 1.17 bar). Accuracy can be customized. within 10 minutes of starting up.
Pressure accuracy:23°C+/-0.3 %FS pressure drift with Sampling gas
・Accuracy measurement of TD up to +/-2 C; ・At -60°C,the display value may jump to -80°C in a short-
・Innovative temperature compensation algorithm and temperature+/-0.01 bar/10°C er time and stay for about 10 minutes,then automatical- flow: 2~4 L/min
multi-point temperature compensation calibration before Response time: 63% [90%],20°C,1bar(gauge),4L/min ly return to the true value of the measurement; sampling gas
leaving the factory greatly improved the temperature Dew point sensor: -80 -> -30 °Ctd 20s [40s] ・Optional Plus Precision Filter pressure: Atmospheric pressure ±10% (air outlet
drift of the sensor and ensured high precision measure- -30 -> -70 °Ctd 5min[20min] ・Man-machine Dialog Menu,Intuitive and Convenient
Pressure response should be atmospheric pressure)
ment in a wide temperature range. ・Timed Automatic Storage,ready to view historical data
time: <1 s Communication:RS232 one-way data communication
・Automatic heating calibration function; anytime
Current output: 4...20 mA(3 lines) range can be changed interface
・Super-fast response speed and excellent long-term stabili- ・Upper and lower alarm value can be set arbitrarily in the
Current output Power supply: 220VAC±10% 50/60Hz
ty; full range.
resolution: 0.002 mA
・Anti-condensation,anti-particulate pollution,oil vapor and Analyzer power consumption<10VA
Temperature drift
most chemicals; of current output: 0.01% of span/°C Chassis
・Multi-point temperature compensation calibration before Current output Dimensions: L×W×H=400mm×300mm×200mm
leaving the factory; load: Maximum 500Ω
・Excellent anti-interference ability; Digital output: RS485 Technical Specifications
・IP65 protection level,even in harsh environment can Connector: 5-pin M12
provide good protection; Display: 128×64 LCD
Automatic heating: 16...30 V/250 mA
Measurement
・Through the standard RS485 interface and powerful Normal Applications
service software,it provides comprehensive sensor measurement: 16...30V/30 mA + 4-20mAcurrent output range: -60°C~+20°C (Basic)
settings,data transmission,software upgrade and mainte- Working -80°C~+20°C (Standard) The invention is suitable for detecting the moisture content
nance functions. temperature: -20...+70 °C -100°C~+20°C(Extended) of various gases in air separation, petrochemical,natural
Storage Sensor principle: Capacitive dew-point sensor gas,metallurgy,electronic power,mechanical manufactur-
temperature: -30...+80 °C Measurement ing and other industries
Relative humidity: 0...95 %RH
method: gas-in type
Sample flow rate: >1 L/min
Technical Specifications Pressure: 0...50 bar Calibration
Protection level: IP65 method: 0.1°C
Dew point
measurement Mechanical parts Resolution: ±3°C(-80~-60°C) Order Information
range: -80...20 °Ctd BM146 connection: ISO G 1/2” Accuracy: ±2°C(-60~+20°C)
-60...20 °Ctd BM147 Stainless steel Repeatability: ±1.5°C ・ Gas path connection mode:
Pressure mesh filter: filter grade<30um<30um Respond time: T90<5min A,Φ6 hose connections (standard)
measurement EMC: IEC 61326-1 B,1/4"-Φ6 Stainless Steel Ferrule Connection
zero drift: ±2%FS/7d
range: absolute pressure 1...17 bar C,1/8"-Φ3 Stainless Steel Ferrule Connection
range drift: ±2%FS/7d
Temperature ・ If the sample gas contains natural gas,the sensor under
environmental
measurement -40...+100°C range can be customized Instructions the standard configuration of analyzer is not suitable
range: temperature: 0~+45°C for the humidity detection in the natural gas environ-
Dew point ・ Working Principle:See page 64 of this sample book. Test ment.If the working condition is natural gas environ-
accuracy: +/- 2 °Ctd (air or nitrogen) ・ Applications:See page 62 of this sample book. environmental ment,the user should explain to the supplier when
Temperature -80 -> -30 °Ctd 20s [40s] temperature: ordering.
-20~+60°C

65 66
Moisture meter P2O5 Moisture meter P2O5

CI-PC382 CI-PC329
Micro-water transmitter Micro-water analysis system
CI-PC382 micro-water transmitter uses electrolysis CI-PC329 humidity analysis system is based on
method to measure micro-water.Its sensor is an electrolytic micro-controller technology.Using P2O5 sensor as measur-
cell.When the measured gas passes through the cell, the
ing unit,it is suitable for measuring 0-500 ppm humidity in
water vapor is absorbed by phosphorus pentoxide-phosphor-
ic acid film coated on the electrode.When DC voltage is various industries and environments.It can provide the
applied at both ends of the electrode,the absorbed water is humidity volume ratio (ppm) display or dew point tempera-
electrolyzed into hydrogen and oxygen,resulting in a limited ture (C) display,users can switch freely.It has the functions
current,the current and the absorbed water.The quantities are of analog signal output,alarm switch output,communica-
proportional.According to Faraday's law,the moisture content tion and so on.
can be calculated.The sensor is placed in the environment
under test,which has fast response,high precision and conve-
nient installation.
Product Features Technical Specifications Product Features Technical Specifications
・In the form of transmitter, KF40 standard flange can be Storage and transportation Environmental temperature: ・The front of the analysis system is covered with a piece /1-5V, freely set mode
installed directly at the test point,and the matching -10~+65 Temperature of toughened glass, which is not only beautiful,but also Load: less than 500Ω
sealing cap can be worn for air measurement. Storage and transportation environment humidity: has good protective effect,making the LCD screen not Environmental
・The circuit adopts digital processing technology,isola- less than 90% RH,no condensate when the storage and easy to be damaged,and prolonging the service life of temperature: +5~+45°C Environmental humidity:less than
tion amplification,frequency cut-off design,and has strong transportation environment temperature is below 5°C,the keys. 80%RH
anti-interference ability. transmitter should be placed in the normal working tempera- ・The latest touch button technology is easy to operate Gas source
ture environment for more than 4 hours before use. and has a long service life. pressure: 0.2-0.5 MPa
・Menu lock switch:to prevent misoperation to change Sample gas
Technical Specifications test pressure: Maximum 0.1 MPa when flowing through the
Principle the parameters of the analysis system to affect its
Sensor principle: Electrolysis normal operation; sensor (first through the pressure regulating
Humidity valve to reduce pressure)
・Data storage function:recording test data regularly and
measurement 电子 氧化铝
alumina P2O5 layer Sample gas
electronics P2O 5层 querying stored data quickly;
range: 0~500ppmV H2O flow rate: 300-400 ml/min
・Alarm function:When the humidity deviates from the
Accuracy: Humidity:reading(+5%)or 0.4 ppm,large value Bypass flow: 1.5-2L/min (for accelerating gas replacement,
alarm value or runs incorrectly,the alarm value can be adjustable as needed)
Reproducibility: +2% (10 ppm) set arbitrarily within the full range.
Stability: +2% FS/7d Sensor life: more than 2 years (normal use)
Response time: Humidity Change:<1s Flow direction Analysis
Recovery Time:T50<2min system life: more than 5 years (normal use)
Heating time
Technical Specifications Analysis
system
after coating: highly dependent on measurement condi- Testing principle:Water Measurement by Electrolysis
water oxygen hydrogen weight: net weight about 16.5 kg
tions Measurement
Two electrodes coated with phosphoric acid were used Cabinet size: L*W*H=400 mm*300 mm*200 mm (exclud-
Coating cycle: Six months,depending on the use,the higher range: 0-500 ppm H2O
to form an electrolytic cell.A constant current voltage ing mounting brackets and joints,etc.)
the measurement concentration,the shorter Accuracy: Measured value (+5%),minimum 0.4 ppm Installation
was applied between the two electrodes.The water in the
the coating cycle. Reproducibility: +2% (10.0 ppm) hole size: L*W=260mm*426mm (4*Φ9 bolt hole)
gas was continuously absorbed by the phosphorus pentox-
Instrument life: more than 5 years (normal use) Stability: +1% FS/7d
ide film as a hygroscopic ant in the cell to form phosphor-
Power supply: 24VDC Response time of
ic acid,which was electrolyzed into hydrogen and oxygen-
Power: less than 15VA humidity
.At the same time, phosphorus pentoxide was regenerat-
measurement: <1 second
Applications
Environmental ed.When the absorption and electrolysis reach equilibri-
temperature: 5~+50°C Recovery time: T50<2 min ・Clean room monitoring,such as glove box;
um,all the water entering the cell is absorbed by the
Environmental humidity:<90% RH Measuring ・Monitoring of protective gas and gas purification system;
phosphorus pentoxide film and electrolyzed.
Measuring method: on-line ・Chemical industry;
The reaction process can be expressed as follows:
ambient pressure:20-340 kPa (30-50 psig) Calibration cycle:one year (recommendation)
P2O5+H2O=2HPO3………………(1) ・Manufacturers and users of scientific and medical gases;
Transmitter Display: 128 *64 LCD
4HPO3=2H2↑+O2↑+2P2O5………………(2) ・Microelectronic devices;
housing: aluminum waterproof box Key: Four keys (touch keys)
Merge (1) and (2): ・Monitoring and inspection of compressed air system;
Power supply: 85-264VAC, 50/60Hz
Probe: stainless steel H2O=H2↑+1/2O2↑………………(3)
Analysis system ・Mechanical equipment engineering;
Installation mode:KF40 flange When the equilibrium between absorption and electroly-
power ・Refrigeration system;
Output: RS485 (standard)/RS232 (optional) sis is reached,all the water entering the cell is pentoxide.
consumption: less than 20VA ・Development and experiment.
Analog signal (optional):4-20mA/0-20mA/ The phosphorus disulfide film is absorbed and electro-
Communication: RS485
0-1V/0-5V/0-10V/1-5V can be set freely lyzed.
Alarm: Alarm output:a set of switching signals
Wiring:5P Aviation Connector Relay contact capacity:24VDC,0.2A
Weight: Net weight 1.1 kg Instructions Instructions
Analog output
Display: No display,you can choose display header Applications:See page 68 of this sample book. signal: 1group,4-20mA/0-20mA/0-1V/0-5V/0-10V Principle:See page 67 of this sample book.

67 68
Thermal conductivity analyzer Thermal conductivity analyzer

CI-PC50 CI-PC53
Thermal conductivity analyzer Portable thermal
conductivity analyzer
CI-PC50 thermal conductivity analyzer uses thermal conduc- CI-PC53 analyzer is a hydrogen concentration detec-
tivity sensor as measuring unit and combines micro-con- tion device based on micro-controller technology and
troller with digital processing technology.It has complete thermal conductivity sensor.It adopts digital processing
self-diagnosis function and monitors the working state of technology,including zero/range calibration,linearization
the instrument at any time.The analyzer has the advan- processing,switch output control,current/voltage output,
parameter setting and other functions,all using digital
tages of intelligence,stability,reliability and long service
processing technology.The analyzer has the functions of
life.It is suitable for accurate measurement of mixed gas
alarm output,communication,external control and analog
concentration in various industries and environments. signal output.It can accurately measure the concentra-
tion of any gas in binary mixture.

Product Features Technical Specifications Product Features Technical Specifications


・With advanced thermal conductivity sensor as measur- gas status signal,etc. ・With microprocessor as the core and thermal conduc- Range:The minimum and maximum possible range is
ing unit and advanced digital processing technology,it Interference Analog signals:2 groups tivity sensor as the measuring unit,it has the character- determined by the type of component under test (gas
has the characteristics of high stability and reliability, etc Compensation: Input Signal Mode:4-20mA/0-20mA/0-1V/ istics of intelligence,stability,high precision and long type) and its application.The minimum ranges listed in
・The front of the analyzer is covered with a toughened 0-5V/0-10V/1-5V calibration cycle. the table below are obtained using N2 as the residual gas
glass,which is not only beautiful,but also has good Sample ・The interference gas compensation function:The analyzer component.For other gases whose thermal conductivity
protection effect. pressure: Purpose: Disturbance gas compensation has the interference gas compensation function to is larger or smaller than N2,the minimum range becomes
・The analyzer has two sets of interference gas compen- atmospheric pressure+10%(outlet should be eliminate the influence of the interference gas on the larger or smaller at the same time.
sation signal input ports,which can eliminate the influence atmospheric pressure) measurement accuracy; Thermal conductivity gas Possible Minimum Range
of interference gas on measurement accuracy. Life of sensor: more than 2 years (normal use) ・Menu lock switch:to prevent misoperation to change the
・The analyzer has an automatic calibration program.Af- Life of analyzer:more than 5 years (normal use) H2 0~100%
parameters of the analyzer and affect its normal opera- He 0~2%
ter the user connects the gas according to the require- Inlet and outlet
Connections: 1/4-inch NPT Internal Thread,Stainless Steel tion;
ment,the analyzer will automatically calibrate and reduce Ar 0~10%
the maintenance work of the user. Material (Standard 1/4-6 card-plastic joint) ・Alarm function:When the gas concentration deviates
from the alarm value,the alarm value can be set arbitrari- CO2 0~20%
・After opening the menu lock switch,the parameters of
ly within the full range. CH4 0~15%
the analyzer can be changed only after entering the Principle
password,to prevent the misoperation from changing H2 in Blast Furnace Gas 0~10%
the parameters of the analyzer and affecting its normal Technical Specifications H2 in acid converter gas 0~20%
Junction
operation. Detection H2 in Wood Gasification 0~30%
Gas
silicon wafer principle: Thermal Conductivity Sensor
Accuracy: ±2%FS
Technical Specifications Repeatability: ±1%FS Applications
Accuracy: +2%FS Stability: ±1%FS/7d ・Gas humidity detection in metallurgical industry;
Repeatability: +1% FS Measuring resistance Response time: T90<30s ・Gas humidity detection in food production and packaging
Stability: +1% FS/7d Charging power process;
Response time: T90<10s supply: 85~264VAC,50/60Hz ・Gas humidity detection in petrochemical process;
Sensor section
Background Power consump- ・Gas humidity detection in power electronics and machinery
gases: N2,Ar,CO2,CH4,etc.(to be specified when order- A silicon wafer manufactured by ultra-micro technology tion of analyzer: Less than 15VA manufacturing industries,etc.
ing) has a measuring film and film resistance.The film resistance Communication:RS485(Standard Matching)/RS232(Optional ・Humidity monitoring during drying agent manufacturing and
Measuring is regulated by a constant temperature,which requires a Matching) plastic substrate drying.
method: on-line current density related to the thermal conductivity of the Alarm: Two sets of switching signals (one set of state
Power supply: 85-264VAC,50/60Hz alarm and one set of concentration alarm) Order Information
sample gas.Then,the rough data are processed to calcu-
Power late the gas concentration.The sensor is placed in an Relay Contact Capacity: 24V DC, 0.2A ・ Air connection mode:
consumption of adiabatic stainless-steel chamber to prevent the influence Analog output A.6 hose connection (standard)
analyzer: less than 25VA of temperature changes in the external environment on signal: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V/ B.1/4'-6 stainless steel jacket connection
Communication: RS485(Standard Matching)/RS232(Optional the measurement.In order to avoid the influence of sample 1-5V,freely set mode Load:less than 500Ω
C.1/8'-3 stainless steel jacket connection;
Matching) gas fluctuation,the sensor is not placed in the main gas Environmental
Working temperature: -10~45°C ・ Filters:GF2800,AF2000;
path.When the sample gas enters,it must be free of dust, ・ Gas composition and measurement range under test;
environment: temperature:-10~+45°C and the condensation of water and gas in the measuring Environmental humidity:less than 80% RH
humidity: less than 90% RH External control: Quantity:Group 1 ・ Measured gas pressure:positive pressure,micro pressure
chamber should be avoided.This is also why most measure- or negative pressure;
Analog output ment tasks require sample gas pretreatment. Control signal:9-28VDC
signal: 1group,4-20mA/0-20mA/0-1V/0-5V/0-10V/ Purpose:Controlling pumps(selection) ・ Disturbance gas:whether it contains CO,CO2,etc.
1-5V,freely set mode Sample
Group 6,relay contact capacity:24VDC,0.2A Instructions pressure: atmospheric pressure ±10%(outlet should be Instructions
Switch signal: 3 groups ・The effects of interfering gases:See page 74 of this sample atmospheric pressure) ・ The effects of interfering gases:See page 74 of this sample
External control: input signal:9-28VDC book. Analyzer weight:net weight 4.25 kg,about 5.25 kg after packaging book.
Purpose:External control calibration,sample ・Applications:See page 73 of this sample book. Packing box: carton L X W X H=470mm X 410mm X 315mm ・ Principle:See page 69 of this sample book.

69 70
Thermal conductivity analyzer Thermal conductivity analyzer

CI-PC55/-1 CI-PC551-2
Explosion-proof thermal Explosion-proof thermal
conductivity analyzer conductivity analyzer
The shell of CI-PC55/-1 hydrogen analyzer is flame- The shell of CI-PC551-2 thermal conductivity analyz-
proof.It adopts Ex component flameproof sign Exd II er is flameproof.It adopts Ex component flameproof sign
C,which is the whole flameproof structure.It can be used Exd II CT6,which is the whole flameproof structure.It can
in dangerous environment of zone 1 and zone 2 formed be used in dangerous environments containing explosive
by explosive gases and their mixtures containing class II gases and their mixtures of Class II C T6 and below.The
C T6 and below.The analyzer can continuously measure
analyzer uses micro-flow thermal conductivity sensor as
the hydrogen concentration of binary mixed gases in the
process.The instrument is a new generation of hydrogen CI-PC55-1 measuring unit.It can accurately measure H2,Ar,He and
analyzer based on thermal conductivity sensor.The digital other gases in various environments, provide gas concen-
processing technology is adopted,including zero/range tration display for users,and output gas concentration signal
calibration,linearization,switching output control,current/- CI-PC55 through analog signal, RS232 and RS485.
voltage output,parameter setting and other functions.
Product Features Technical Specifications Product Features Technical Specifications
・With microprocessor as the core and thermal conductiv- CI-PC55-1: L×W×H=375×315×179mm ・It combines micro-controller with digital processing techno- CI-PC551-2 Thermal Conductivity Gas Analyzer is used to
ity sensor as the measuring unit,it has the characteris- Explosion-proof Level:Exd || CT6 logy to resist cross-interference and is stable and reliable. measure the volume percentage of hydrogen,argon,deu-
tics of intelligence,stability,high precision and long calibra- (Certification) ・The latest touch button technology is easy to operate and terium and helium in binary mixed gases.According to the
tion cycle. has a long service life. needs of different users,different components and ranges
Range:The minimum and maximum possible range is
・The interference gas compensation function:eliminat- of analyzers can be provided,but users must explain to the
determined by the type of component under test (gas ・With infrared remote-control function,the analyzer can be
ing the influence of the interference gas on the measure- supplier when ordering.
type) and its application.The minimum ranges listed in operated by remote control.
ment accuracy; Measuring Minimum
the table below are obtained using N2 as the residual gas ・Menu lock switch:to prevent misoperation to change the Background gas range Maximum range
・Menu lock switch:to prevent misoperation to change the component.For other gases whose thermal conductivity
components
parameters of the analyzer and affect its normal opera- parameters of the analyzer and affect its normal operation; atmosphere 0~1% 0~99.99%
is larger or smaller than N2,the minimum range becomes ・Alarm function:When the gas concentration deviates from
tion; N2(Nitrogen) 0~1% 0~99.99%
larger or smaller at the same time. the alarm value,the alarm value can be set arbitrarily within
・Data Storage:It supports data storage of U disk and SD H2 O2(Oxygen) 0~1% 0~99.99%
card.It has large data storage capacity and is conve- Thermal Conductive Gas Minimum range possible the full range.
nient for users to process and analyze data. (Hydrogen) Ar(Ar) 0~1% 0~99.99%
H2 0~1%(95~100%)
He 0~2%
Technical Specifications CO(carbon monoxide) 0~1% 0~99.99%
Technical Specifications Ar 0~10% Sensors: Micro-fluidic Thermal Conductivity Sensor atmosphere 0~1% 0~99.99%
Detection CO2 0~20% Accuracy: +2%FS Ar(Ar) N2(Nitrogen) 0~1% 0~99.99%
principle: Thermal Conductivity Sensor CH4 0~15% Repeatability: +1%FS O2(Oxygen) 0~1% 0~99.99%
Accuracy: ±2%FS H2 in Blast Furnace Gas 0~10% Stability: +1% FS/7d
CO2(carbon dioxide) 0~1% 0~99.99%
Repeatability: + 1%FS H2 in acid converter gas 0~20% Response time: T90<30s
Stability: +1% FS/7d Display D2(Deuterium) N2(Nitrogen) 0~1% 0~99.99%
H2 in Wood Gasification 0~30%
Response time: T90<30s resolution: 0.01% He(Helium) N2(Nitrogen) 0~1% 0~99.99%
D2 0-1%(95%-100%)
Protection level: IP64 Explosion-proof
SF6 0-1%(95%-100%)
Power supply: 24VDC grade: Exd II CT6 Applications
Power waste: Less than 15VA Protection level: IP65
Communication:RS485 (Standard Matching)/RS232 (Option- Calibration ・Pure gas monitoring; ・Chemical application;
al Matching) Applications cycle: One year (recommendation) ・Air separation; ・Wood gasification;
Alarm: Alarm output: a set of switching signals Power supply: 24VDC ・Protective gas monitor-・Blast Furnace Gas
・Detection of the volume percentage of excess hydro-
Relay Contact Power waste: Less than 20VA ing; ・Acidic converter gas;
gen in hydrogen production process; ・Hydrogen monitoring; ・Monitoring equipment for hydro-
Capacity: 24VDC,0.2A Communication:RS485 or RS232
・Detection of hydrogen volume percentage in circulat- ・Synthetic gas detection; gen refrigeration generator.
Analog output Analog output
ing gas of hydrogen refrigeration unit in power plant; signal: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V/ ・Gas production;
signal: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V/
1-5V,freely set mode Load: less than 500Ω ・Detection of hydrogen content in ambient air and indus- 1-5V,freely set mode Load: less than 500Ω
Environmental trial containers; Switch output: Alarm value:1 set
・Detection of hydrogen content in production process of Order Information
temperature: -10~45°C Relay Contact Capacity:24VDC,0.2A
Environmental humidity:less than 90% RH fertilizer plant,such as volume percentage of hydrogen Environmental ・Air connection mode:A.6 hose connection (standard),
Sample flow rate:200-400 ml/min in supplementary gas and circulating gas in ammonia temperature: -10~+45°C B.1/4'-6 stainless steel jacket connection,C.1/4'-3
Sample pressure:Atmospheric pressure ±10% (outlet should production process. Environmental humidity:less than 90% RH stainless steel jacket connection;
be atmospheric pressure) Sample flow ・The composition and measurement range of the
Inlet and outlet: 1/4-inch NPT internal thread,stainless steel rate: 200-400 ml/min measured gas and the possible interference gases.
material (standard 1/4-6 card-plastic joint) Sample
Instructions
Sensor life: More than 2 years (normal use) pressure: Atmospheric pressure ±10% (outlet should Instructions
Instrument life: More than 5 years (normal use) ・ The effects of interfering gases:See page 74 of this be atmospheric pressure) ・The effects of interfering gases:See page 74 of this
CI-PC55: L×W×H=300×200×175mm ・ sample book. Sensor life: More than 2 years (normal use) sample book.
Flowmeter:Selection Instrument life: More than 5 years (normal use) ・Principle:See page 69 of this sample book.

71 72
Thermal conductivity analyzer Thermal Conductivity Analyzer

CI-PC56 CI-PC511
Thermal conductivity analyzer Thermal conductivity analyzer

CI-PC56 analyzer is a gas analyzer with micro-con- CI-PC511 analyzer is a gas analyzer with micro-con-
troller as its core and thermal conductivity sensor as its troller as its core and thermal conductivity sensor as its
measuring unit.The analyzer has the advantages of intelli- measuring unit.The analyzer has the advantages of intelli-
gence,stability,reliability and long service life.It is suitable gence,stability,reliability and long service life.It is suitable
for accurate measurement of hydrogen,argon,helium and
for accurate measurement of hydrogen,argon,helium and
deuterium concentration in binary mixed gases in various
deuterium concentration in binary mixed gases in various
industries and environments.In addition to standard
industries and environments. applications,other special applications,including measure-
ment components and residual interference gases,can be
customized according to user requirements.

Product Features Technical Specifications Product Features Influence of interfering gas


・With microprocessor as the core,it has the characteris- Alarm output: Two groups of gas concentration alarm ・With microprocessor as the core and thermal conductiv- It is necessary to understand the influence of oxygen
tics of intelligence,good stability and high reliability. switch output,two groups of range label ity gas sensor as the measuring unit,it has the character- composition on the determination of interference gas in
・The thermal conductivity sensor is used as measuring switch output (automatic range),a group of istics of intelligence,good stability,high accuracy and residual gas.
error alarm switch output long calibration cycle. The following table shows the effect of 10% residual gas
unit with high accuracy and long calibration period.
Relay contact ・Automatic calibration function:The analyzer has automatic (interfering gas) on the zero point of measurement (mea-
・Automatic range:According to the range of gas concen-
capacity: calibration function.After connecting the standard gas sured in% H2)
tration,the range of analog output can be automatically 24VDC,0.2A
switched to improve the precision of analog output. Range: according to the method specified by the manufactur- Zero correction
The possible minimum and maximum range is determined er,it can automatically complete the calibration of the
・The interference gas compensation function:eliminat- Ar -1.28%
by the type of component (gas type) under test and its analyzer.
ing the influence of the interference gas on the measure- +1.59%
application.The minimum ranges listed in the table below ・Menu lock switch:to prevent misoperation to change the CH4
ment and improving the measurement accuracy;
are obtained using N2 as the residual gas component.For parameters of the analyzer to affect its normal operation; C2H6(Nonlinear response) -0.06%
・Menu lock switch:to prevent misoperation to change the
other gases whose thermal conductivity is larger or small- ・Alarm function:When the gas concentration deviates
parameters of the analyzer and affect its normal opera- C3H8 -0.80%
er than N2,the minimum range becomes larger or smaller from the alarm value,the alarm value can be set arbitrari-
tion; CO -0.11%
at the same time. ly within the full range.
・Alarm function:When the gas concentration deviates from
CO2 -1.07%
the alarm value,the alarm value can be set arbitrarily within Thermal Conductive Gas Possible Minimum Range
the full range. He +6.51%
H2 0~100% Technical Specifications
He 0~2% N2O +1.08%
Technical Specifications Sensors: Thermal Conductivity Sensor
Ar 0~10% Accuracy: ±2%FS NH3(Nonlinear response) +0.71%
Accuracy: ±2%FS CO2 0~20% Repeatability: ±1%FS O2 -0.18%
Repeatability: ±1%FS CH4 0~15% Stability: ±1%FS/7d SF6 -2.47%
Stability: ±1% FS/7d Response time: T90<30s
H2 in Blast Furnace Gas 0~10% Monitor: 240×128 LCD SO2 -1.34%
Response time: T90<30s
Power supply: 85~264VAC,50/60Hz H2 in acid converter gas 0~20% Power supply: 85~264VAC,50/60Hz Air(dry) +0.25%
Environmental H2 in Wood Gasification 0~30% Power waste: Less than 35VA
Communication:RS485(Standard Matching)/RS232 (Option- When the residual gas concentration is not 10%,the
temperature: 5~45°C
al Matching) approximate results can still be obtained by using the
Environmental humidity:less than 90% RH
Switch output: Concentration alarm:2 groups,others:4 groups data in the table above.Even if the residual gas concentra-
Sample Applications tion is as high as 20%,the data in this table are still valid
pressure: Atmospheric pressure ±10% (outlet should Relay Contact Capacity:24VDC,0.2A
be atmospheric pressure) ・High purity gas monitoring; ・Chemical application; Analog output (depending on the type of gas).The thermal conductivity
External control ・Air separation; ・Wood gasification; signal: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V of most gas mixtures is non-linear.Even in a certain
signal: A set of 9-28VDC signals can be input to ・Protective gas monitoring; ・Blast Furnace Gas; /1-5V,freely set mode Load:less than 500Ω concentration range,such as NH3/N2 mixtures,ambiguous
control pumps (optional) ・Hydrogen monitoring; ・Acidic converter gas; External input: Interference Compensation:Two Groups results may be given.In addition to zero,the linear gradient
Interference gas ・Synthetic gas detection; ・Monitoring equipment for (Analog Signals) is also affected by residual gases.However,for most
compensation ・Gas production; hydrogen refrigeration External control:5 groups (9-28 VDC) gases,this effect is almost negligible when their concen-
signal: Input two sets of compensation signals of generator. Environmental tration is low.
4-20mA interference gas temperature: -10~+45°C
Analog output: Standard configuration of two groups of Environmental humidity:less than 80% RH
Sample pressure: Atmospheric pressure ±10% (outlet should
Instructions
4-20mA analog output,through the menu Instructions
freely set 4-20mA,0-20mA,0-1V,0-5V, 0-10V be atmospheric pressure) ・ Order knowledge: Please refer to page 86 of this sample
output mode ・ The effects of interfering gases:See page 74 of this Sample flow rate: 200-400 ml/min book.
Communication:RS485 (Standard Matching)/RS232 (Option- sample book. Carton packing: LxWxD=483mmx177mmx300mm ・ Range:Please refer to page 70 of this sample book.

Principle:See page 69 of this sample book. L*W*H=600mm*450mm*330mm ・ Principle:See page 69 of this sample book.
al Matching)

73 74
On line hydrogen analyzer On line hydrogen analyzer

CI-PC562 CI-PC582
Micro-hydrogen analyzer Trace hydrogen transmitter
CI-PC562 micro-hydrogen analyzer is a high-perfor- The CI-PC582 trace hydrogen transmitter uses an
mance intelligent instrument with imported high-perfor- electrochemical sensor as the measurement unit.After
mance micro-hydrogen sensor as measuring unit and electrical processing of the sensor signal amplification,fil-
microprocessor as core.It adopts digital processing technol- tering,linearization correction,and standard signal output,
ogy,and its zero/range point calibration,linearization the microprocessor calculates the hydrogen concentra-
processing,switching output,analog signal output,param-
tion value in the sample gas.And output analog signal
eter setting and other functions all use digital processing
(standard 4-20mA) for the secondary processing of
technology.It has the characteristics of intelligence and
high precision,and is suitable for accurate measurement hydrogen signal by the user
of hydrogen concentration in various industries and environ-
ments.
Product Features Technical Specifications Technical Specifications Terminal function description
・Advanced electrochemical hydrogen sensor is used as Sample Measuring terminal
identification Features Colour
measuring unit,which has high accuracy,good stability pressure: Atmospheric pressure ±10% (outlet should range: 0~10000ppm H2
and long service life. be atmospheric pressure) Sensor: Electrochemical hydrogen sensor 24V+ Transmitter power supply 24VDC anode Red
・128*64 LCD can display hydrogen concentration,date, Sample flow Accuracy: ±2%FS Transmitter power supply 24VDC
time and other parameters at the same time,which is rate: 400~600ml/min Repeatability: Cv<1%FS GND negative pole and analog output Yellow
rich in content and intuitive. Sensor life: More than 2 years (normal use) Stability: ±1%FS/7d signal 4-20mA negative pole
・When the concentration of hydrogen is higher than the Instrument life: More than 5 years (normal use) Response time: T90<90s
4-20mA+ Analog output signal 4-20mA positive Blue
protective concentration,the pump is opened automati- Relay contact Resolution: 1ppm
cally and air is introduced to the sensor.The sensor capacity: 24VDC,0.2A Measurement 485A RS485 communication terminal A White
must avoid working in the environment with hydrogen Alarm output: Group 2 (COM and NO) medium: O2,N2,Ar,etc.
485B RS485 communication terminal B Brown
concentration higher than 1% for a long time to prolong Communication:RS485/RS232 bidirectional communication Sensor life: Sensor life:more than 2 years (normal use)
its service life. Analog signal: Group 1 (mode 4-20 mA/0-20 mA/ 0-1V/ Analyzer life: Analyzer life:more than 5 years (normal use) Note:In order to avoid electric shock,when connecting
・Alarm function:If the hydrogen concentration deviates 0-5V/0-10V/1-5V) Power supply: 24VDC,power consumption is less than 6VA terminals to other equipment,it is necessary to make sure
from the alarm value or when the operation is wrong,the Ambient that the connection is correct before connecting the
alarm value can be set arbitrarily within the full range. temperature: 0~45°C power of the analyzer.
・Analog output:Isolated analog signal output,4-20mA/0-20 Ambient humidity:<80% RH Warning:Do not short the terminals or short the terminals
mA/0-1V/0-5V/0-10V/1-5Vanalog output mode can be Applications Sample gas to the chassis at will to avoid damaging the device.
set freely through menu; pressure: normal pressure ±10%
・Communication function:RS485 (standard) and RS232 ・Nitrogen purification of PSA; Installation: KF50 vacuum flange
・Detection of trace hydrogen in hydrogen production
Transmitter installation
(optional) two-way communication. Output configuration
process; Analog output: 4-20mA(standardconfiguration)
・Detection of hydrogen concentration in ambient air and /0-20mA/0-1V/0-5V/0-10V/1-5V
Technical Specifications industrial containers; Communication: RS485(connected with display meter head) Transmitter
・Detection of hydrogen concentration in the production
Sensors: Electrochemical hydrogen sensor
process of chemical fertilizer plant;
Range: 0~10ppm/2000ppm/2.000% H2
・Detection of trace hydrogen in high temperature sintered Clamp
Accuracy: ±2% FS
protective gases such as magnetic materials and various
Repeatability: ±1% FS
mixed gases.
Stability: ±1% FS/7d
Response time: T90<70s(0~1000ppm) Seal ring

Background
Installation components
gases: Nitrogen,argon,etc.
Welding point
Measurements: On-line
Key: Four keys (touch keys)
Power supply: 85~264VAC,50/60Hz
Environmental
The conduit
temperature: -10~50°C
Environmental
humidity: Less than80%RH

75 76
On line hydrogen analyzer On line hydrogen analyzer

CI-PC502 CI-PC512
Selective hydrogen Selective hydrogen
content analyzer content analyzer
CI-PC502 analyzer uses a solid-state sensor to CI-PC512 analyzer uses solid-state hydrogen sensor
detect hydrogen,which is specific to hydrogen and has no to detect hydrogen.The sensor is specific to hydrogen
cross-sensitivity to other gases.It combines micro-con- and has no cross-sensitivity to other gases.It combines
troller with digital processing technology,has complete microcontroller with digital processing technology,has
self-diagnosis function,and has the advantages of intelli- complete self-diagnosis function,and has the advantages
gence,stability,reliability and long service life.The analyz- of intelligence,stability,reliability and long service life.The
er is suitable for accurate measurement of hydrogen analyzer is suitable for accurate measurement of hydro-
concentration in mixed gases in various industries and gen concentration in mixed gases in various industries
environments.It provides users with hydrogen concentra- and environments.It provides users with hydrogen concen-
tion display and outputs hydrogen concentration through tration display and outputs hydrogen concentration through
analog signals and communication analog signals and communication.
Product Features Technical Specifications Product Features Technical Specifications
・The sensor has specificity to hydrogen and no cross Power supply: 85~264VAC,50/60Hz ・The sensor has specificity to hydrogen and no cross Communication: RS485 (Standard Matching)/RS232 (Optional
sensitivity to other gases. Power sensitivity to other gases. Matching)
・Hydrogen concentration,menu,data and working state consumption of ・The 240*128 LCD window shows the gas concentra- Alarm: Alarm output:6 sets of switching signals
of the instrument are displayed by 240*128 LCD win- analyzer: less than 25VA tion,menu,data and the working state of the instrument, Relay Contact Capacity:24VDC,0.2A
dow,which is intuitive and rich in content. Environmental which is intuitive and rich in content. Analog output: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V
・The front frame of the analyzer is covered with a piece temperature: Gas:-20~+60°C Operation:-10~+55°C ・The front frame of the analyzer is covered with a piece /1-5V,analog output mode can be set
of toughened glass,which has a good protective effect Storage:-20~+60°C of toughened glass,which is not only beautiful,but also Load:less than 500Ω
on LCD screen,keys,etc. Environmental has a good protective effect on the LCD screen and keys. External control:Quantity:5 groups
・The latest touch button technology is easy to operate humidity: less than 90%RH ・Menu lock switch:to prevent misoperation to change Control signal:9-28VDC
Sample the parameters of the analyzer to affect its normal opera- Sensor life: More than 2 years (normal use)
and has a long service life.
pressure: Atmospheric pressure ±10% (outlet should tion; Analyzer life: More than 5 years (normal use)
・Menu lock switch:to prevent misoperation to change
be atmospheric pressure) ・Convenient data storage function:The analyzer has the Environmental
the parameters of the analyzer to affect its normal
Sample flow functions of automatic storage and manual storage of temperature: -10~45°C
operation;
rate: 0.1~10slpm(recommendation1.0slpm) test data,and supports U disk and SD card,which has a Environmental humidity:less than 80%RH
・Convenient data storage function,support U disk and Communication: Interface:DB9 large amount of data storage. Sample flow rate:0.1-10 SLPM (recommendation 1.0 slpm)
SD card,large amount of data storage; Communication mode:RS485 (standard ・Alarm function:When the hydrogen concentration devi- Sample pressure: Atmospheric pressure ±10% (outlet should
・When the hydrogen concentration deviates from the matching)/RS232 (optional matching) ates from the alarm value,the alarm value can be set be atmospheric pressure)
alarm value, the alarm value can be set arbitrarily within Modbus RTU Protocol arbitrarily within the full range. Inlet and outlet: 1/4NPT (Standard 6.5 Stainless Steel Joint)
the full range. Switching signal:6 groups (2 groups of concentration alarm,
4 groups of status alarm)
Relay contact Technical Specifications
Technical Specifications capacity: 24VDC, 0.2A
Analog signal: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V Scope of Applications
Scope of
/1-5V,freely switchable output mode measurement: 0.01%~10% H2(customizable range)
measurement: 0.01%~10% H2(customizable range) ・Detection of the volume percentage of excess hydro-
Load:less than 500Ω Accuracy: 0.3%
Accuracy: 0.3% gen in hydrogen production process;
External input Repeatability: 0.2%
Repeatability: 0.2% ・Detection of hydrogen volume percentage in circulating
signal: Quantity:5 groups Stability: 0.2%/7d
Stability: 0.2%/7d gas of hydrogen refrigeration unit in power plant;
Input signal:9-28VDC Response time: T90<30s
Linearity: 0.2%
Linearity: 0.2% ・Detection of hydrogen content in ambient air and indus-
Calibration
Concentrations of trial containers;
background gas:N2
Response time: 30s Applications CO and H2S: 0 ・Detection of hydrogen content in production process of
Background fertilizer plant,such as volume percentage of hydrogen
Display ・Detection of the volume percentage of excess hydro- gases: N2,CO2,He,Ar,alkanes,olefins and alkynes in supplementary gas and circulating gas in ammonia
resolution: 0.01% gen in hydrogen production process; Other inert gases,excluding CO and H2S
Concentrations ・Detection of hydrogen volume percentage in circulating production process.
Calibration
of CO and H2S: 0 gas of hydrogen refrigeration unit in power plant; background gas: N2
Background ・Detection of hydrogen content in ambient air and indus- Monitor: 240×128 LCD screen
gases: N2,CO2,He,Ar,alkanes,olefins,alkynes and trial containers; Key: Four keys (touch keys)
other inert gases shall not contain CO and ・Detection of hydrogen content in production process of Data memory: SD card (standard)/U disk (optional)
H2S. fertilizer plant,such as volume percentage of hydrogen Power supply: 85~264VAC,50/60Hz
Sensor life: More than 2 years (normal use) in supplementary gas and circulating gas in ammonia Power consump-
Analyzer life: More than 5 years (normal use) production process. tion of analyzer: Less than 30VA

77 78
On line hydrogen analyzer High temperature hygrometer

CI-PC552 CI-TP19
Selective explosion-proof Textile high temperature
hydrogen content analyzer humidity meter
The shell of CI-PC552 hydrogen analyzer is flame- The CI-TP19 features unique tuning capabilities and
proof.It adopts Ex component flameproof sign Exd II B, a number of innovative and unmatched designs.In many
which is the whole flameproof structure.It can be used in process,in order to ensure the quality of products,use
dangerous environment of zone 1 and zone 2 formed by energy efficiently or achieve the goal of emission reduc-
explosive gases and their mixtures containing class II B tion,it is necessary to monitor and control the humidity of
T6 and below.The analyzer can continuously measure the
process gas.CI-TP19 is a process humidity meter,which
hydrogen concentration of binary mixed gases in the
process.The instrument is a new generation of hydrogen is suitable for the most stringent industrial requirements,
analyzer based on solid-state hydrogen sensor.The digital including corrosion resistance,continuous operation and
processing technology is adopted,including zero/range insensitivity to fouling.At the same time,we will push the
calibration,linearization,switching output control,current/- sensor technology to a new height with higher perfor-
voltage output,parameter setting and other functions. mance,long life and stability.
Product Features Technical Specifications Product Features Technical Specifications
・The sensor has specificity to hydrogen and no cross Working ・Used to measure water content in air or other gases.In consumption: less than 20VA
sensitivity to other gases. environment: -10~+45°C many process,in order to ensure the quality of products, Calibration cycle:It is recommended to calibrate every other
・The 128*64 LCD window is used to display hydrogen Sample pressure:Environmental humidity:less than 90% RH use energy efficiently or achieve the goal of emission year
concentration,set data and the working state of the Atmospheric pressure ±10% (outlet should reduction,it is necessary to monitor and control the Measured ambient
instrument,which is intuitive and easy to operate. be atmospheric pressure) process gas humidity; temperature: Probe:100~500°C
・With the latest touch key technology,it is easy to operate Sample flow rate: 0.1-10 SLPM (recommendation 1.0 slpm) ・Can be measured in the worst process environment, Ambient temperature of electrical module:
and has a long service life. Instrument such as:high temperature medium;humidity saturated -10~+50°C
・Menu lock switch:to prevent misoperation to change weight: Net weight is about 5 kg,after packaging medium;dust,oil,lipids,sulfides,solvents and strongly Storage
the parameters of the analyzer and affect its normal about 15 kg corrosive media; environment: Temperature:-20~+60°C
operation; Sensor life: More than 2 years (normal use) ・Humidity measurements can be performed continu- Humidity:less than 90% RH
・Data Storage:Supporting data storage of U disk and SD Instrument life: More than 5 years (normal use) ously and can replace laboratory measurements Sample gas
card,data storage is large and convenient for users to Alarm output: Group 1 ・The microprocessor system is used to monitor all the pressure: normal pressure±10% (only during ventilation)
process and analyze data;Timing data storage inside Relay Contact Capacity:24VDC,0.2A parameters in the measurement process and monitor Sample gas flow: 800~1000ml/min (only during ventilation)
the instrument is convenient for users to quickly view Communication: RS485 (Standard Matching)/RS232 (Option- the instrument itself,so the maintenance of the equip- Communication: Interface:terminal block Communication
test data; al Matching) ment is very small. method:RS485(standard)/RS232 (optional)
・Alarm function:When the hydrogen concentration External control: Quantity:Group 1 Modbus RTU protocol
deviates from the alarm value,the alarm value can be Control signal:9-28VDC Technical Specifications Analog signal: 1 group,4-20mA/0-20mA/0-1V/0-5V/ 0-10V
set arbitrarily in the full range. Analog output: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V /1-5V,can set analog output mode
・Communication function:RS485 (standard) and RS232 /1-5V,analog output mode can be set Measuring range:TP19 0-40%vol H2O load:less than 500Ω
(optional) two-way communication can be used to TP19-1 0-100%vol H2O
communicate directly with computers or other digital Sensor: Ion flow humidity sensor
communication equipment. Accuracy: ±2%FS(Accuracy is only available for Applications
communication output,analog signals may
Applications be addi-tional error in signal acquisition) Able to work in harsh working conditions that other
Repeatability: ±1%FS humidity analyzers can not work in,the measurement of
Technical Specifications ・ Detection of the volume percentage of excess hydro- Stability: ±1%FS/7d humidity in harsh media containing acids or other corro-
Range: 0.01%~10% H2 (customizable range) gen in hydrogen production process; Response time: Fully preheated,T90 less than 60s sive substances (such as sulfuric acid or aqua regia)
Accuracy: 0.3% ・ Detection of hydrogen volume percentage in circulat- Background gas: N2,He,Ar and other inert gases,and can ・Fume in the field of power ・ Mining equipment for
Repeatability: 0.2% ing gas of hydrogen refrigeration unit in power plant; not contain Si,Pb,etc. generation copper ore containing
Stability: 0.2%/7d ・ Detection of hydrogen content in ambient air and indus- Display: 128×64 OLED screen ・Unpurified incinerator flue gas sulfuric acid in measured
Linearity: 0.2% trial containers; Wiring method: terminal ・Textile field medium
Calibration ・ Detection of hydrogen content in production process of Installation: DN50 standard flange ・Hot air system in fast food ・ Ore sintering
background gas: N2 fertilizer plant,such as volume percentage of hydrogen Sensor life: more than 2 years (normal use) production ・ Copper nickel ore
Response time: T90<30s Analyzer life: more than 5 years (normal use) ・oven ・ Large combustion plant
in supplementary gas and circulating gas in ammonia
Concentrations of Working method: online ・Baking equipment ・ Waste incineration plant
production process.
CO and H2S: 0 Probe insertion ・Dryer
Background gases:N2,CO2,He,Ar,alkanes,olefins and alkynes depth: 500mm,1000mm,1200mm,1500mm or
Other inert gases,excluding CO and H2S other sizes
Explosion-proof Sampling
grade: Exd || BT6 method: Plug-in measurement Instructions
Protection level: IP64 Power: 24VDC
Power supply: 24VDC,power consumption less than 15VA Analyzer power Principle:See page 81 of the this brochure

79 80
High temperature hygrometer High temperature hygrometer

CI-PC193 CI-PC196-1
Food processing high High temperature and
temperature and humidity system humidity system
CI-PC193 high temperature and humidity system for The CI-PC196-1 high temperature and humidity system is
food processing is a humidity analysis system with micro- an oxygen and humidity analysis system based on microproces-
processor as the core and ion current humidity sensor as sor and ion flow humidity sensor.It has the characteristics of
the measurement unit.It has the characteristics of intelli- intelligence, high precision,comprehensive function,etc.It is
gence, high precision,and comprehensive functions.It is suitable for the measurement of oxygen and humidity in
various industries and environments.
suitable for measuring humidity in a mixed gas of
0-99.99% water vapor and air in various industries and
environments.

Product Features Technical Specifications Product Features Technical Specifications


・It has the characteristics of intelligence,good stability, humidity: less than 90%RH ・It has the characteristics of intelligence,good stability, System power
high reliability and long calibration period. Probe use ambient high reliability and long calibration period. consumption: Not greater than 30VA
・Menu lock switch:Preventing error operations from temperature: 0~220°C ・The 240x128 LCD window displays oxygen concentra- Communication: RS485 (standard)/RS232 (optional)
affecting the analysis system Measurement tion and humidity,menu,data and instrument working Sensor life: Greater than 2 years (normal use)
・Data storage and retrieval functions:Test data is method: ejection type state,etc.The display is visual and rich in content. System life Greater than 5 years (normal use)
recorded regularly and stored data can be quickly Meter installation: wall-mounted ・The surface of the LCD screen window is covered with System usage
queried System cabinet a piece of tempered glass to protect the LCD screen ambient
・Automatic calibration:Automatic calibration of instru- installation size: L×W=560mm×360mm(hole spacing) and buttons, etc. temperature: -10~50°C
ment Probe installation: threaded or flanged ・The new touch key technology is adopted,the operation Probe ambient
・Free setting of humidity display mode:can be set freely is simple,and the key service life is long. temperature: 0~500°C
as a percentage/dew point/absolute humidity display ・Menu lock switch:The analysis system is prevented Measurement
mode through the menu Principle from being affected by misoperation. method: ejection
・Communication function (optional):RS485/RS232 ・Data storage capabilities:The test data is recorded System cabinet
(optional) bidirectional communication can be used to regularly and stored data can be quickly viewed; installation: Wall-mounted
Determination of tail gas
directly communicate with computer or other digital ・Automatic calibration features:The calibration of the System cabinet
Zirconium oxide
communication equipment; instrument is automatically completed according to installation
alumina
・Isolated analog signal output,can be freely set through the instrument setup. dimensions: L×W=560mm×360mm
the menu 0-20mA/4-20mA/0-1V/0-5V/0-10V/1-5V analog exhaust
Zirconium oxide
・Auto Blowback:According to the instrument setup,the Probe installation:flange installation
output mode heater alumina instrument can be automatically cleaned.
Zirconium oxide
・Isolated analog signal output,0-20mA can be set freely
Technical Specifications It uses voltage to ionize oxygen ions and mix with water through the menu/4-20mA/0-1V/0-5V/0-10V analog Applications
vapor.By measuring the current value, the content of output mode;
Model: CI-PC193 ・The installation and maintenance are convenient. Humidity measurement in food processing;humidity
oxygen ions and water vapor can be obtained.The measurement in the chemical and fiber fields;humidity
Measuring range: 0~99.99% H2O extremely small holes formed on the cathode side limit
Measurement measurement in wood,building materials and paper indus-
the inflow of gas,and when the oxygen concentration is try;Measurement of High Temperature and Humidity in
accuracy: ±2%FS constant,the output current value no longer increases Technical Specifications
Repeatability: ±1% FS CEMS of Coal-fired and Oil-fired Boilers;In the printing and
with the increase of the applied voltage and reaches a Sensor: Ion flow humidity sensor dyeing industry field,the flat dyeing process,humidity
Stability: ±1% FS/7d constant value.The constant current value is called For Measurement measurement in high temperature (120-500°C).
Response time: T90≤60s(Fully preheated) the ion current value at this oxygen concentration, range: O2:0~25.00%,H2O:0~40.00%
Sensor: Ion current humidity sensor according to this principle,when the sensor is placed in Measurement
Relay contact an environment containing water vapor and the working accuracy: 0~1% O2 ±3%FS
capacity: 24V DC,0.2A voltage of the sensor is further increased,a very signifi- 1~25% O2 ±3%R
Order Information
Power supply: 220V AC±10%,50/60Hz cant second ion current value can be measured (see the 0~40.00% H2O ±2%FS You can't have the following in your sample:
nstrument power figure) The first step I1 value and the second step I2 value Repeatability: 0~1% O2 ±1.5%FS 1.Corrosive gases such as HF,Cl2,HCl,SO2,H2S,etc.
consumption: less than 30VA are respectively proportional to the oxygen partial pressure 1~25% O2 ±1.5%R 2.Toxic substances such as Si,Pb,P,Zn,Sn,As,etc.
Communication and the oxygen partial pressure containing water vapor. 0~40.00% H2O ±1%FS 3.Reducing components,hydrocarbons,such as ethanol
(optional): RS232/RS485
Stability: 0~1% O2 ±1.5%FS/7d
Sensor life: more than 2 years (normal use)
1~25% O2 ±1.5%R/7d
Analyzer life: more than 5 years (normal use) Instructions
0~40.00% H2O ±1%FS/7d Instructions
System use ambient
Application fields and ordering instructions:see page 82 Response time: T90≤30s(Fully Preheated)
temperature: 0~50°C Principle:please refer to page 81 of this sample volume.
of this brochure. Power supply: 85~264VAC,50/60Hz
System use environment

81 82
High temperature hygrometer High temperature hygrometer

CI-PC39 Technical Specifications

Constant current injectionsystem or for forward/reverse control proportion-


al valve.
for high temperature and humidity Analog output
mode: It can be set to 4-20mA/0-20mA/0-1V/0-5V
The CI-PC39 system uses the principle of dry and wet
/0-10V/1-5V.
temperature measurement,which is measured by the
Allow load: Less than 500Ω
difference between dry and wet temperature sensors.
Alarm output
Because the humid temperature sensor is in a humid
environment,the temperature of the measured gas will Switching signal:Two (one for humidity alarm and one for
decrease due to the evaporation and heat absorption of status alarm)
the water around the sensor,resulting in the difference Relay contact
between the dry temperature and the wet temperature.By capacity: 24VDC,02A 1.water tank 3.wet temperature 5 Pt100:Dry bulb temperature(DB)

calculating the difference, the humidity of the gas can be work environment 2.pumps measuring tank 6 Pt100:Wet bulb temperature(WB)
4.airstream
accurately obtained.Dry-wet temperature method is one Environmental
of the most reliable gas humidity measurement methods, temperature: +5~+50°C
which can obtain high precision,high reproducibility menu in 4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V output Storage
measurement results without any calibration.CI-PC39 mode. temperature: - 20~+70°C (no condensate)
system can be operated in high temperature and humidity Environmental Applications
environment for a long time. It is one of the most humidity: Less than 90% RH
advanced high temperature and humidity analysis equip- Mechanical data ・Flue gas in the field of power generation;
ment in the world. Technical Specifications Shell: Stainless steel case,protection grade ・Unpurified incinerator flue gas;
IP64, according to DIN40050 ・Textile field;
Humidity measurement
Product Features Shape size: L*W*H=704mm*279mm*362mm ・Hot air system in fast food production;
Principle of
・With microprocessor as the core,real-time monitoring Weight: About 28KG ・Oven, baking equipment;
measurement: Shock jet method
of all parameters in the measurement process,and Electrical data ・Copper mining equipment containing sulphuric acid in
Sensors: Temperature sensor
monitoring of the system itself,in order to maintain a Whole power ・measured gas;
Accuracy: ±2%FS
good state of operation,make the system long-term supply: 220VAC±10%,50/60Hz ・Dryer;
Repeatability: ±1%FS
stability, high reliability,small maintenance; Stability: ±1%FS/7d Tropical power ・Ore sintering, etc.
・Humidity control function:According to the require- supply: 110VAC/220VAC,50/60Hz ・When other humidity analyzers can not work in harsh
Response time: T90<90s(10~190g/kg)
ment of humidity and concentration control,the system Back-blowing box conditions,the measurement of humidity in acid or other
Water injection
output control signal to adjust the opening of propor- power supply: 85~264VAC,50/60Hz corrosive substances (such as sulfuric acid,hydrofluor-
volume: Maximum 3.3ml/min (peristaltic pump)
tional valve,to control the inflatable flow in the process, Connect ic acid or Aqua regia) can be placed in a separate
Water reserves: 10L (enough for 3 days)
to obtain and maintain the humidity range required by Over-wire
Compressed air position,which is the biggest characteristic and incom-
the measured environment.Its advantage is to use the connector: Five waterproof joints
injection: 0.4-0.5 MPa (Maximum Air Consumption parable advantage of this product.
minimum gas consumption to maintain the maximum Tracheal
quality of the product,reduce scrap and rework; 2000L/min)
Measurement parameters interface: G1/4”
・It is suitable for measuring water content in air or other Heating pipe
gases:in many processes,in order to ensure product Dry temperature: 0~140°C
Wet temperature:0~140°C interface: G3/8 (IP54) Universal Conical Connector
quality,improve energy efficiency or achieve emission
External DKR
reduction targets,process humidity needs to be monitored;
temperature: 0~200°C DIN3863
・It can work in high temperature and humidity environ- Dry material Papermaking Gypsum fiberboard Roasting coffee
Absolute Water tank joint:G1/4 (with 6 fast connector)
ment for a long time.
・It does not need calibration and is especially suitable pressure: 500~1500hPa
for continuous production conditions. Dew point
・It can measure the humidity continuously and replace temperature: 20~100°C Principle
the laboratory measurement.It adopts the latest touch Volume ratio: 2~100% Firstly, the measured medium determines the flow rate by
button technology,which is easy to operate and has a Absolute Textile finalize Tobacco baking
the pressure difference of the measured gas through the
long service life. humidity: 15~1000g/kg
・Menu lock switch:prevent misoperation,change system Venturi tube;after the measured gas flows through the
Specific humidity:15~1000g/kg Venturi tube,the dry temperature is measured by the dry
parameters and affect its normal operation; Heat content: 35~1000kJ/kg
・Alarm function:When the humidity deviates from the temperature sensor;after the dry temperature is measured,the
Water pressure: 10~1000hPa measured gas flows through the flake nozzle to form an
alarm value,the alarm value can be set arbitrarily within
Saturation impinging jet,which impinges on the water level of the wet
the full range.
pressure temperature measuring pool.The humidity-temperature
・Communication function:RS232 (standard) and RS485
difference: 0~1000hPa sensor is placed in the center of the humidity-tempera-
(optional) two-way communication can be used to
Analog output ture measuring device,and the measured dry and wet
communicate directly with computers or other digital
communication equipment; Analog output: Two-way isolated analog output signal can temperature signals are transmitted to the electronic system
・Isolated analog signal output can be set freely through be used for corresponding humidity value unit for analysis.

83 84
High temperature hygrometer Nitrogen oxygen compound analyzer

CI-PC156 CI-PC791
Explosion-proof Nitroxide compounds analyzer
high temperature humidity meter
CI-PC156 explosion-proof high temperature humidity The CI-PC791 analyzer is a nitrogen oxide gas analyz-
meter uses ion current humidity sensor as measuring unit,and er with micro-processor as the core and a double-cell
controls the working voltage of the sensor to measure oxygen
thick-film zirconium oxide ion flow sensor as the measur-
content,oxygen and water (gas) content respectively.According
ing unit.It is intelligent,high precision and comprehensive
to oxygen content,oxygen and water (gas) content,according to
the content of oxygen,oxygen and water (gas),the humidity in function.It is suitable for the measurement of NOx gas
value is calculated according to the functional relationship in various industries and environments.
between the content of oxygen,oxygen and water (gas) and the
output signal of the sensor.The shell of the analyzer is flame-
proof,which is a whole flameproof structure.It can be used in
dangerous environments containing explosive gases and their
mixtures of Class II C T6 and below.
Product Features Technical Specifications Product Features Technical Specifications
With the combination of micro-controller and digital
・・ tion of analyzer: High temperature type:less than 20VA,low ・It has the characteristics of intelligence,good stability, Communication: RS485 (standard)/RS232(optional)
processing technology,the analyzer has complete self-di- temperature type:less than 60VA high reliability and long calibration period. Analog signal
agnosis function,intelligence,stability and reliability. Calibration cycle: It is recommended to calibrate every other year. ・The dual-cell thick-film zirconia ion sensor can detect output: 2 groups,4-20mA/0-20mA/0-1V/0-5V/
・Ion current humidity sensor is a measuring unit with The measured nitrogen oxides and oxygen at the same measurement 0-10V/1-5V(can be set)
high accuracy and long calibration cycle. Environmental Switching signal: 4 groupsrelay contact capacity:24VDC,
point;
・With the latest touch key technology,the keys are sensi- temperature: High temperature type:180-500°C 0.2A
low temperature type: below 180°C ・The NOx analysis of SCR equipment is mainly used to
tive,reliable,easy to operate and long service life. Analog signal input:2 groups4-wire system 4-20mA (stan-
Environmental Temperature of Electrical analyze NOx and NO2,or the total NOx of both,which is
・Integral structure design,easy installation,zero mainte- dard) or 4-wire system 4-20mA (optional)
nance; Module:-10~+50°C different from the common NOx analysis, avoiding the Digital signal input:4 groups,9~28VDC (standard)/switching
・Menu lock switch:avoid misoperation to affect the normal Storage high analysis error caused by neglecting the NO loss value (optional)
environment: Temperature:-20~+60°C from NO to NO2,and saving the operation cost of NOx
operation of the analyzer; Ambient
Humidity:Less than 90% RH reduction for thermal power enterprises.
・Data Storage Function:Record test data regularly and temperature: -10~50°C
Sample
query stored data quickly. ・The results show that the CO2,H2O and SO2 can be Ambient humidity:less than 90% RH
pressure: Atmospheric pressure±10%(only during
ventilation) prevented by the unique sensor. Sample gas
Sample flow ・Data storage:Test data is recorded regularly and stored pressure: normal pressure ± 10% (air outlet should
Technical Specifications data can be quickly viewed or queried; be atmospheric pressure)
rate: 800-1000ml/min (limited to ventilation)
Scope of Communication:RS485/RS232(can be switched by software) ・The detection limit of NOX is 1ppm.After denitration,it
measurement : 0~40.00%vol H2O Modbus RTU Protocol should be set at the minimum range of 0~200ppm.In Applications
Sensors: Ion Current Humidity Sensor Switching signal: Alarm value:1 addition, the range ratio of this instrument can be up to NOx detection in denitration system
Accuracy: ±2%FS (Accuracy only applies to communi- Relay output:2 groups (1 group concentra- ・
cation output,analog signal may have addition- 20 times,before denitration,it can be set to 0~2000ppm. NOx detection of desulphurization units;
tion alarm,1 group status alarm) ・
al errors due to signal acquisition relay contact capacity 24VDC 0.2A Therefore,the instrument can be used for pre-denitra- ・ Exhaust emissions from ship engines
Repeatability: ±1%FS Analog signal: Quantity:2 groups tion detection and post-denitration detection,and can ・ Detection of NOx and O2 in various combustion devic-
Stability: ±1%FS/7d Output mode:4-20mA/0-20mA/0-1V/0-5V/ guarantee the detection accuracy. es and systems;
Response time: After full preheating,T90 is less than 60s 0-10V/1-5V,switchable output mode
Background ・ Detection of NOx in exhaust gas from combustion in
Load:less than 500Ω
gases: N2,He,Ar and other inert gases shall not Technical Specifications boilers,power plants,etc.
contain Si,Pb,hydrocarbons,etc. Sensor: Double-cell thick film zirconium oxide ion
Explosion-proof Applications Order Information
current sensor
level of chassis: Exd || CT6 ・Humidity measurement in coal-fired and oil-fired boiler Measuring ・ Air connection:A,Φ6 hose connection (standard) B1/4"-Φ
Chassis exhaust emissions (CEMS); range: 0~25.00% O2,0~500ppm NOx 6 stainless steel jacket connection C,1/8"-Φ3 stainless
protection level: IP65
・Humidity measurement in food processing; Accuracy: NOx: 0~100ppm ±5ppm
Sensor life: More than 2 years (normal use) steel jacket connection;
・Humidity measurement in wood,building materials and 100~500ppm ±10ppm
Analyzer life: More than 5 years (normal use) ・ Filters:GF2800,AF2000;
paper industry; O2: 0~25% ±2% FS
Weight: The net weight of the probe is about 10.3 kg ・ Measured gas composition and range;
(1 meter probe).The probe increases or ・Humidity measurement in chemical and fibre fields; Repeatability: NOx: 0~100ppm ±2.5ppm ・ Pressure of measured gas: positive pressure,micro-
decreases by about 1 kg for every 0.4 meter ・In the field of printing and dyeing industry,flat-width dyeing 100~500ppm ±5ppm pressure or negative pressure;
increase or decrease in weight. process,humidity measurement at high temperature (120- O2: 0~25% ±1% FS ・ the main components of the measured gas,corrosive
Probe insertion 180°C),etc. Stability: ±1% FS/7d gas,chloride,etc.
depth: 500mm,1000mm,1200mm,1500mm or other Response time:T90≤10s(Fully Preheated)
dimensions customized Instructions Power supply: 24VDC Instructions
Power supply: 24VDC Analyzer power
Power consump- Principle:See page 81 of this sample book. Principle:See page 87 of the this brochure
consumption: less than 20VA

85 86
Nitrogen oxygen compound analyzer Nitrogen oxygen compound analyzer

CI-PC79 CI-PC71
Nitrogen oxide compound Nitrogen oxidation gas analyzer
analysis system
The CI-PC79 analysis system is a nitrogen oxide gas CI-PC71 analyzer uses double pool thick film zirconia
analysis system with a microprocessor as the core and a ion sensor as measuring unit,and combines micro-con-
dual-cell thick-film zirconia ion sensor as the measure- troller with digital processing technology.It has complete
ment unit.It has the characteristics of intelligence,high self-diagnosis function and monitors the working state of
precision and comprehensive functions,which is suitable the instrument at any time.The analyzer has the advan-
tages of intelligence,stability,reliability and long service
for the measurement of nitrogen oxide gas in various
life.It is suitable for accurate measurement of nitrogen
industries and environments.
oxides in mixed gases in various industries and environ-
ments.

Product Features Technical Specifications Product Features Technical Specifications


・It has the characteristics of intelligence,good stability, Probe use ambient ・It has the characteristics of intelligence, good stability, Power
high reliability and long temperature: 0~220°C high precision and long calibration cycle. consumption of
・The oxygen and nitrogen compounds can be detected Measurement ・Oxygen concentration,NOx concentration, menu, data analyzer: Less than 35VA
at the same measuring point by using a double-cell method: ejection type and instrument working state are displayed by 240*128 Communication:RS485(Standard)/RS232(Optional)
thick-film zirconia ion sensor System cabinet LCD window,which is intuitive and rich in content. Alarm: Six sets of switching signals
・It is not affected by CO2,SO2,H2O (gas) and other interfer- installation: wall-mounted ・Using double cell thick film zirconia ion sensor as measur- Relay Contact Capacity: 24VDC, 0.2A
ing gases System cabinet ing unit,the detection of nitrogen oxides and oxygen can Analog output: Two groups,4-20mA/0-20mA/0-1V/0-5V/
・Detect and analyze the denitration efficiency of the installation size: L×W=633.5mm×368mm be carried out at the same measuring point. 0-10V/1-5V,analog output mode can be set
SCR device. The system mainly analyzes NO and NO2, Probe installation: flange mounting ・It is not affected by interfering gases such as CO2,SO2
Load:less than 500Ω
and H2O.
or the total amount of NOx,which is different from the External control:Quantity:5 groups
・Testing and analyzing the denitrification efficiency of
general analysis system that can only analyze NO to Control signal:9-28VDC
SCR device,the main analysis of NO and NO2,or the total
avoid high analysis error caused by ignoring the NO Sensor life: More than 2 years (normal use)
Principle amount of NO2,is different from the general analyzer
loss of NO conversion into NO2.Save denitration opera- which can only analyze NO,avoiding the high analysis Analyzer life: More than 5 years (normal use)
tion costs for thermal power companies; error caused by neglecting the loss of NO converted Environmental
Basic principle of high-precision NOx sensor
・Menu lock switch:Preventing error operations from affect- into NO2,and saving the operation cost of denitrifica- temperature: -10~50°C
ing the analysis system Electrode without reducing NO tion for thermal power enterprises. Environmental humidity:Less than 90% RH
O2- O2-
・Data storage:Test data is recorded regularly and stored ・Menu lock switch:to prevent misoperation to change the Sample flow

Zirconium oxide
Determination of tail gas second chamber

data can be quickly viewed or queried NOx(NO,NO2) O2


NO2
External discharge
NO NO NO
N2 parameters of the analyzer to affect its normal opera- rate: 200-400 ml/min
O2 CO CO2
・Automatic calibration:The calibration of the instrument H2 HC H2O N2
Unburned components CO2,H 2O
first chamber
O2
tion; Sample
is completed automatically according to the setting of Electrode without reducing NO O2- O2- ・Automatic calibration function:can automatically complete pressure: Atmospheric pressure+10% (outlet should
the instrument the calibration of the analyzer; be atmospheric pressure)
1:Removal of oxygen from the exhaust gas in the first chamber
・Active and Anti-blowing:According to the setting of the 2:Combustion of flammable gases in the first chamber in advance ・Alarm function:When the concentration of oxygen and Out of breath: 1/4 NPT (Standard 6.5 Stainless Steel Joint)
instrument,the instrument can be automatically cleaned. 3:Conversion of NO2 in the exhaust to NO in the first chamber NOx deviates from the alarm value, the alarm value can Cabinet size: LXWXH=483mmX300mmX177mm
4:Reduction of NO with NO reducing agent in the second chamber to be set arbitrarily in the full range.
measure the amount of oxygen produced by decomposition
Technical Specifications ex. 2NO N2+O2

O2 is controlled at a very low concentration,so that NO is Applications


Sensor: dual-cell thick-film zirconia ion sensor
reduced to N2 and O2,and the reduced oxygen is Technical Specifications
Measuring range:0~25.00% O2,0~500ppm NOx ・ Detection of NOX in denitrification system;
Accuracy: NOx: 0~100ppm ±5ppm measured to be converted into NO.For the denitration Sensors: Double cell thick film zirconia ion sensor
project,I hope to measure the two key parameters of ・ Detection of NOx in desulfurization unit;
100~500ppm ±10ppm Range: 0~25.00% O2,0~500ppm NOx
nitrogen oxide (NOx=NO+NO2) concentration and oxygen Accuracy: NOx: 0~99.9 ppm: ±5ppm ・ Exhaust Gas Emission Detection of Marine Engine;
O2: 0~25% ±2% FS
(O2) concentration at the same time.This instrument just 100~500ppm: ±10ppm ・ Detection of NOx and O2 in various combustion devic-
Repeatability: NOx: 0~100ppm ±2.5ppm
100~500ppm ±5ppm meets the requirements.There are no redundant projects O2: 0~25.00 %: ±2%FS es and systems;
O2: 0~25% ±1% FS and no additional equipment.It is desulfurization (denitra- Repeatability: NOx: 0~99.9 ppm: ±2.5ppm ・ Detection of NOx in exhaust gas from combustion of
Stability: ±1% FS/7d tion).The most ideal analytical method. 100~500ppm: ±5ppm boilers and power plants.
Response time: T90≤30s (Fully preheated) Basic chemical reaction: O2: 0~25.00 %: ±1%FS
Power supply: 85~264VAC,50/60Hz Stability: NOx: 0~99.9 ppm: ±2.5ppm/7d
communication:RS485 (standard)/RS232 (optional) 100~500ppm: ±5ppm/7d
Sensor life: more than 2 years (normal use) O2: 0~25.00 %: ±1%FS/7d Instructions
Instructions Response time: T90<60s(after full preheating)
System Life: Greater than 5 years (normal use) Principle:See page 87 of this sample book.
System use ambient Application industry:see page 86 of this brochure Measurements: One year (recommended)
temperature: -10~50°C Power supply: 85~264VAC,50/60Hz

87 88
Optical gas analyzer Optical gas analyzer

CI-PC20 CI-PC21
Infrared gas analyzer Infrared gas analyzer

CI-PC20 analyzer is an infrared gas detection device The selective absorption of infrared rays by gas
based on the principle of NDIR (non-spectroscopic infrared) molecules is the basis of the design of infrared gas
with micro-controller technology as the core.It has complete analyzer.Polar molecules such as SO2,NOx,CO,CH4 have
self-diagnosis function and monitors the working state of permanent electric dipole torches,and therefore have the
the instrument at any time.The analyzer has the advantag- structure of vibration and rotation.According to quantum
es of intelligence,stability,reliability and long service life.It
mechanics,the energy levels are divided into splitting
is suitable for the concentration measurement of carbon
levels,which can be coupled with the incident characteris-
dioxide,carbon monoxide,methane and other gases in
various industries and environments. tic long infrared radiation to produce absorption.Different
polar molecules have different absorption bands.

Product Features Product Features Technical Specifications


・Using NDIR (non-dispersive infrared measurement),the dimensions: LxW=225mmx180mm (rectangular hole) ・ The specially designed air chamber absorber has strong Maximum load:Provided according to user's requirement,not
sensor is not in contact with the measured gas,and the Fixed hole size:L*W=252mm*170mm (6*4 bolt hole) anti-interference ability and high detection accuracy. affected by load within 500Ω of maximum
poisoning phenomenon of the sensor will not occur. ・ High stability infrared light source,constant tempera- load
・High stability infrared light source and strong anti-inter- Principle ture control of receiver,good stability of instrument; Environmental
ference filter make the analyzer stable for a long time. ・ Measuring chamber mirror gold plating,corrosion temperature: -10~45°C
・With microprocessor as the core,it has the characteris- resistance; Environmental humidity:less than 80% RH
filter
tics of intelligence,stability,high precision and long calibra- ・ Isolated analog signal output,4-20mA/0-20mA/0-1V/ Power supply
tion cycle. 0-5V/0-10V/1-5V analog output mode can be set freely. voltage: 85-264VAC 50/60Hz
・Menu lock switch:prevent misoperation to change the ・ Alarm function:When the gas concentration deviates Shape size: 19-inch profile case
parameters of the analyzer to affect its normal opera- Infrared light source infrared sensor from the alarm value,the alarm value can be set arbitrari- LXWXH=483 mmX300 mmX177 mm
tion. ly in the full range. The measured
Infrared signal

・ RS485 (standard matching)/RS232 (optional matching) gas flow rate: 500-1000ml/min,the best:500 ml/min
Technical Specifications was adopted. Dust: Particles not exceeding1 um,not exceeding
200 ug/Nm3
Detection Mist: none
principle: NDIR,Non-dispersive Infrared (Double Beam) Technical Specifications Pressure: Atmospheric pressure ±10%(outlet should be
Measurement Model: CI-PC21 atmospheric pressure)
wavelength(μm)
Accuracy: ±2%FS Principle of Water content: Saturation (no condensation) not exceeding
Repeatability: ±1%FS Most organic and inorganic polyatomic molecular gases measurement:NDIR Non-Spectrophotometric Infrared Analyzer 5°C
Zero drift: ±1%FS/7d have specific absorption wavelength in the infrared Measuring
Range drift: ±1%FS/7d region.When infrared light passes through,the transmis- components: NOx,SO2,CO,CO2,CH4,H2S can be measured
Response time:T90<15s(500ml/min) sion intensity of these gaseous molecules to specific for any one or two components,and O2 can Applications
Power supply: 85~264VAC,50/60Hz wavelength can be expressed by Lambert-Beer law:I=I0 be added to each component.
Power consump- Range can be Minimum range Maximum range It is widely used in gas analysis of petroleum,chemi-
e-kpl,and the absorption intensity I can be expressed as designed according
tion of analyzer: Less than 35VA cal,smelting,building materials,light industry and other
I=I0-I=I0 (1-e-kpl).In the formula,I0 is the intensity of incident to requirements
Communication: RS485(Standard Matching)/RS232(Optional furnaces,kilns or flues.It is a reliable testing tool for environ-
light,I represent the intensity of transmission light,L is the NOx 0~1000ppm 0~20%
Matching) mental monitoring,bioengineering,medical and health research
thickness of gas medium,P is the concentration of gas,K SO2 0~500ppm 0~100%
Alarm: Alarm value: 2 work.
is the absorption coefficient.In the gas chamber,the infrared CO 0~20ppm 0~100%
Relay Contact Capacity: 24V DC, 0.2A light source emits the infrared band light,and the energy
Analog output CO2 0~10ppm 0~100%
of the light is absorbed by the gas in the gas chamber.The CH4 0~200ppm 0~100%
signal: Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V/ total energy absorbed corresponds to the concentration Order Information
1-5V,freely set mode H2S 0~1000ppm 0~30%
of all gases in the gas chamber.The radiation detector only
Load: less than 500Ω Accuracy: ±2%FS ・Pneumatic connection mode:
responds to this wavelength because it integrates an
External control:Quantity:5 groups Control signal:9-28VDC Repeatability: ±1%FS A,6 hose connection (standard)
infrared filter for a specific wavelength of the gas being
Environmental Zero drift: ±1%FS/7d B,1/4'-6 Stainless Steel Sleeve Connection
measured.The electrical signal obtained by the detector
temperature: -10 ~+45 ℃ Range drift: ±1%FS/7d C,1/8'-3 Stainless Steel Sleeve Connection
corresponds to the light energy absorbed by the gas under test.
Environmental Humidity:Less than 80% RH Linear error ・Filters:GF2800,AF2000;
Sample limit: ±1%FS ・Gas composition and measurement range under test;
pressure: Atmospheric pressure + 10% (outlet should Instructions Response time:T90≤60s(when sample flow gas volume is ・Measured gas pressure:positive pressure,micro pressure
be atmospheric pressure) ・Measuring Components and Range:See page 91 of this 0.5L/min) or negative pressure;
Cabinet size: L*W*H=310mm*275mm*190mm sample book. Analog signal: 4~20mA/0~20mA/0~1V/0-5V/0-10V/1-5V,- ・The main components,impurities and sulfides of the
Installation ・Application:Please refer to page 92 of this sample book. free to set analog output mode measured gas.

89 90
Optical gas analyzer Optical gas analyzer

CI-PC23 CI-PC261
Portable infrared gas analyzer Infrared gas analyzer
CI-PC23 analyzer is an infrared gas detection equip- CI-PC261 infrared gas analyzer uses the world's
ment based on the principle of NDIR (infrared) with advanced infrared gas detection technology and digital
micro-controller technology as the core.It uses digital processing technology.Its zero/range calibration,linear-
processing technology,including zero/range calibration,- ization,temperature compensation,switch output,current/-
linearization processing,switch output control, current/- voltage output,parameter setting and other functions.It
voltage output,parameter setting and other functions.It
has the characteristics of intelligence and high precision,and
uses digital processing technology.The analyzer has
is suitable for accurate measurement of measured gas
functions of alarm output,communication,external control,
analog signal output and so on. concentration in various industries and environments.

Product Features Technical Specifications Product Features Technical Specifications


・Using NDIR (non-dispersive infrared measurement),the Relay contact ・ NDIR or non-dispersive infrared measurement is adopt- signal: 9~28VDC(group 2)
sensor is not in contact with the measured gas,and the capacity: 24V DC,0.2A ed.The sensor does not touch the measured gas,and Alarm output: Two sets of alarm switch output
poisoning phenomenon of the sensor will not occur. Analog the poisoning phenomenon of the sensor will not Relay contact
・High stability infrared light source and strong anti-inter- output signal:Group1,4-20mA/0-20mA/0-1V/0-5V/0-10V/ occur. capacity: 24VDC,0.2A
ference filter make the analyzer stable for a long time. 1-5V,freely set mode ・ It has the characteristics of intelligence,good stability, Instrument size: W×H×D=144mm×144mm×251mm
・With microprocessor as the core,it has the characteris- Load: less than 500Ω high reliability and long calibration cycle. Installation hole
tics of intelligence,good stability,high precision and long External ・ Menu lock function:prevent misoperation to change size of instrument: L×W=136mm×136mm
calibration cycle. control: Quantity:Group 1 Control signal:9~28VDC the parameters of the analyzer and affect its normal
・Menu lock switch:prevent misoperation to change the Analyzer Purpose:Controlling pumps (selection) operation;
・ Two-way single-pole single-throw alarm function,the
Applications
parameters of the analyzer to affect its normal opera- weight: Net weight 4.25kg,about 5.25kg after packaging
tion. Packing box: L×W×H=470mm×410mm×315mm alarm value can be set freely within the full range; ・ Industrial control:industrial flue gas emission monitor-
・ The utility model has the advantages of simple struc- ing,such as flue gas analyzer;motor vehicle exhaust
ture,convenient operation and maintenance. emission monitoring,such as exhaust gas analyzer;
Technical Specifications Applications ・ Petroleum exploration:gas detection in petrochemical
Measuring component and range process, gas composition analysis in petroleum explo-
・Industrial control,such as industrial flue gas emission Technical Specifications ration, such as mud logging analyzer;
Measuring Component Minimum range Maximum range monitoring;
Detection principle: NDIR,Non-dispersive Infrared (Double ・ Air quality monitoring:fresh air system,HVAC industry
CO2 0~2000ppm 0~100% ・Petroleum exploration,such as gas detection in petro- air quality monitoring,such as CO2 module;
Beam) Measurement
CO 0~5000ppm 0~100% chemical process and gas composition analysis in petro- ・ Medical:Human breathing gas monitoring,such as
Measurement range: (Sensors are selected according to range)
leum exploration; end-of-breath CO2 sensor;
CH4 0~4.4% 0~100%
・Air quality monitoring,such as fresh air system,HVAC Measuring Component Minimum range Maximum range ・ Biogas analysis:monitoring of biogas content in
Instructions for Order:Measuring Components and Ranges of
the analyzer shall be explained to the Supplier at the time of industry; CO 0~2% 0~100% landfill,sewage treatment plant and biogas engineer-
ordering. ・Biogas analysis,such as gas content monitoring in CO2 0~2000ppm 0~100% ing,such as biogas analyzer;
Detection landfills,sewage treatment plants and biogas projects; CH4 0~4.4% 0~100% ・ Industrial fluid welding process (Ar/N2 CO2).
principle: NDIR,Non-dispersive Infrared(Double Beam) ・CO2(Ar/N2) detection in industrial fluid welding process, SF6 0~50ppm 0~1000ppm
Measurement etc.
Accuracy: ±2%FS Accuracy: ±2% FS
Repeatability: ±1%FS Repeatability: ±1% FS Order Information
Order Information Zero drift: ±1% FS/7d
Zero drift: ±1%FS/7d ・ Air connection mode:
Range drift: ±1%FS/7d ・Pneumatic connection: Range drift: ±1% FS/7d
Response time: T90<15s(500ml/min) A,6 hose connection (standard)
Response time:T90<15s(500ml/min) A,Φ6 hose connection (standard)
Power supply: 85~264VAC,50/60Hz B,1/4'-6 stainless steel jacket connection
Charging power B,1/4-Φ6 stainless steel jacket connection
Environmental C,1/8'-3 stainless steel jacket connection;
supply: 85~264VAC,50/60Hz C,1/8-Φ3 stainless steel jacket connection
temperature: 5~45°C Environmental humidity:<90%RH ・ Filters:GF2800, AF2000;
Power waste: Less than 20VA ・Filters:GF2800, AF2000;
Sample Atmospheric pressure ± 10%(outlet should ・ Gas composition and measurement range under test;
Communication:RS485(Standard)/RS232(Optional) ・Gas composition and measurement range under test;
pressure: be atmospheric pressure) ・ Measured gas pressure: positive pressure,micro pressure
Environmental ・Measured gas pressure:positive pressure,micro pressure
Communication:RS485(Standard)/RS232(Optional) or negative pressure;
temperature: -10~45℃ or negative pressure;
External control ・ The main components and background gases of the
Environmental humidity: less than 80% RH ・Whether to equip pumps and needle valves.
signal: A set of 9-28VDC signal controlled pumps measured gases.
Sample pressure:Atmospheric pressure ±10% (outlet should
be atmospheric pressure) can be accessed (optional)
Instructions Analog output: Group 1,4-20 mA/0-20 mA/0-10 V,can be Instructions
Alarm: Two sets of switching signals (one set of state
alarm and one set of concentration alarm) set by menu
Principle:See page 89 of this sample book. Principle:See page 89 of this sample book.
External input

91 92
Optical gas analyzer Optical gas analyzer

CI-PC25/-1 CI-PC2200
Explosion-proof Ultraviolet analyzer
infrared gas analyzer
The shell of CI-PC25-1 infrared gas analyzer is flame- CI-PC2200 ultraviolet analyzer is a flue gas analyzer
proof.It adopts Ex component flameproof sign Exd II C, product independently developed by our company for
which is the whole flameproof structure.It can be used in on-line gas analysis in environmental protection and
dangerous environment of zone 1 and zone 2 formed by industrial control field at home and abroad.The analyzer
explosive gases and their mixtures containing class II C can measure the concentration of SO2,NOx,O2 and other
T6 and below.The analyzer can continuously measure the gases.It has the characteristics of high measurement
concentration of a component of the mixed gas in the CI-PC25-1 accuracy,high reliability,fast response time and wide
process,such as carbon monoxide,carbon dioxide and application range.Its various indicators reach or exceed
methane.The instrument is a new generation of infrared the same kind of products at home and abroad.
gas analyzer based on NDIR (non-dispersive infrared) CI-PC25
principle,which adopts digital processing technology.
Product Features Technical Specifications Product Features Technical Specifications
・Using NDIR (non-dispersive infrared measurement),the /1-5V,freely set mode ・Ultraviolet absorption spectroscopy gas analysis Accuracy: ±2%FS
sensor is not in contact with the measured gas,and the Load:less than 500Ω technology and stoichiometric algorithm:SO2,NOx and Repeatability: ±1%FS
poisoning phenomenon of the sensor will not occur. Sensor life: More than 2 years (normal use) other gases are the most advanced on-line analysis Response time: T90<10s
・High stability infrared light source and strong anti-inter- Instrument life:More than 5 years (normal use) methods,the detection limit reaches 0.1 ppm.Com- Lower
ference filter make the analyzer stable for a long time. CI-PC25: L×W×H=300×200×175mm pared with NDIR,the measurement accuracy is completely detection limit: SO2/NO:1ppm,O2:0.1%
・Menu lock switch:prevent misoperation to change the Flowmeter: Selection independent of moisture and dust (Vapor-phase water Zero drift: ±2%FS/7d
parameters of the analyzer and affect its normal opera- CI-PC25-1: L×W×H=375×315×179mm does not absorb ultraviolet light,while liquid-phase Range drift: ±2%FS/7d
tion. Explosion-proof Level:Exd II CT6 (Certifica- water and dust do not absorb ultraviolet light selective- Stability: The change of indication within one hour is
tion) ly,which is a slow change in spectra.),and has the no more than 2%.
advantages of low detection limit,low temperature drift Environmental
Technical Specifications and so on.The range ratio reaches 10:1 and supports temperature: -10~50°C Environmental humidity:<95% RH
Detection principle: NDIR, Non-dispersive Infrared (Double Applications automatic range switching. Sample
Beam) Measurement ・Return gas chamber:multiple return to 1.5 M optical pressure: Current Environmental Pressure ±0.1Bar
・Industrial control,such as industrial flue gas emission path,lower detection limit; Analog input: 4-20mA,2-way,flexible configuration
Measuring Component Minimum range Maximum range
monitoring; ・Pulsed xenon lamp is used as light source,its life is 109 Analog output: 4-20mA,4 channels,output content configu-
CO2 0~2000ppm 0~100% ・petroleum exploration,such as gas detection in petro- times:calculated according to 3 times per second,its rable
CO 0~5000ppm 0~100% chemical process,gas composition analysis in petro- life is 10 years;Pulsed xenon lamp is a cold light source, Switch output: 14 channels,output content configurable
CH4 0~3% 0~100% leum exploration; which has the advantages of long life,good stability and Communicatio
Measuring background gases must be gas with no ・Air quality monitoring,such as fresh air system,HVAC no preheating time compared with infrared light source. n mode: Route 1:232,Route 1:485
overlapping absorption peaks of argon,oxygen,hydrogen industry air quality monitoring; ・No optical moving parts:no optical moving parts,such as Power/power: 220VAC,120W
and other measured gases. ・Biogas analysis,such as monitoring of biogas content slice,interferometer,etc.,with high reliability,field vibration Instrument
Accuracy: ±2%FS in landfill,sewage treatment plant and biogas project; will not damage the instrument,and has no impact on size: L×W×H=482×320×133mm
Repeatability: ±1%FS ・CO2(Ar/N2) detection in industrial fluid welding process the measurement;
Zero drift: ±1%FS/7d etc. ・NOx is obtained by direct measurement of NO and NO2 Applications
Range drift: ±1%FS/7d without NO2 NO converter:NO and NO2 are absorbed in
・Continuous monitoring CEMS (analysis of SO2,NO,NO2,
Response time: T90<15s(500ml/min) the ultraviolet band.By measuring NO and NO2 simulta- O2) for flue gas emission in power plants;
neously and accumulating NOx,the cost of purchasing
Protection level: IP64 Order Information ・Monitoring of desulfurization process (analysis of SO2
Calibration cycle: One year (recommendation) NO2 NO converter is saved for customers,and the reliabili- and O2);
Power supply: 24VDC ・ Air connection mode: ty of the system is improved. ・Monitoring of denitrification process (analysis of NO,
Power waste: Less than 15VA A,6 hose connection (standard) ・Modular design is adopted:light source,spectrometer, NO2,NH3,O2);
Communication:RS485(Standard)/RS232(Optional) B,1/4'-6 stainless steel jacket connection HMI module,gas chamber,interface module and so on. ・Continuous monitoring of waste incineration flue gas
・ C,1/8'-3 stainless steel jacket connection; It has high reliability,good expansibility and convenient emissions (analysis of SO2,NO,NO2,O2);
Environmental
temperature: -10~45°C ・ Filters:GF2800, AF2000; maintenance.It can easily add CO(electrochemistry) and ・Trace Cl2 analysis (analysis Cl2) of PVC process and iron
Environmental humidity: less than 90% RH Gas composition and measurement range under test; CO2 (infrared) measurement module. white powder production process in chlor-alkali plant;

Sample flow rate:500~1000ml/min(optimum 500ml/min) The main components,impurities and sulfides of the ・Gas analysis of sulfur recovery process (analysis of
measured gas. SO2 and H2S);
Sample pressure:Atmospheric pressure ±10% (outlet should Technical Specifications ・Gas analysis of natural gas purification process (analy-
be atmospheric pressure)
Range: SO2 0-100/500/2000 ppm or more,custom- sis of trace H2S);
Alarm: Alarm value:1 ・Analysis of chloromethane in coal chemical industry
Analog output Instructions izable,UV principle
(CH3Cl);
signal: Relay Contact Capacity:24VDC, 0.2A NO 0-100/500/2000 ppm or more,custom-
Principle:See page 89 of this sample book. ・On-line atmospheric monitoring (analysis of SO2,NO2,
Group 1,4-20mA/0-20mA/0-1V/0-5V/0-10V izable,UV principle
O3) and so on.
O2 0-25%,electrochemical principle

93 94
Optical gas analyzer Optical gas analyzer

CI-PC68/-1 CI-PC6500
Laser gas analyzer In-situ laser gas analyzer
CI-PC68/-1 laser gas analyzer is an optical device for CI-PC6500 in-situ laser gas analyzer is a process gas
Diffusion type
measuring oxygen concentration in gases.It includes a analysis system based on semiconductor laser absorp-
measuring probe installed in the shell of electronic equip- tion spectroscopy (TDLAS) technology.It can measure
ment.It is often used in inert gas generator,fermentation gas concentration and other parameters on-line in various
environments(especially in high temperature,high pressure,
and composting process monitoring,flue gas measure-
strong corrosion and other harsh environments).It has
ment,inert gas seal and oxygen lack monitoring in strict Flange type high accuracy, fast response speed and high reliability.It
environment. is convenient for production optimization,energy recov-
ery,safety control,environmental protection monitoring
and scientific research and analysis.
Through mode
Product Features Technical Specifications Product Features Measurement parameters
・The optional sampling chamber can be used for high compensation ・CI-PC6500 (in situ); Lower limit of
Gas measurement measuring range
temperature treatment,pressure lifting and direct contact accuracy: ±0.25%reading
・Laser in-situ measurement has fast response and high O2 0.01%Vol. 0~1%Vol.,0~100%Vol.
probe or sampling chamber options in extremely harsh The influence of background gases:
CO2 concentration below 6% <1% readings measurement accuracy.
mechanical environment. CO 40ppm 0~8000ppm,0~100%Vol.
The gas dew point below 30ºC<1% readings ・Integrated positive pressure explosion-proof design,
・Resistance to corrosive chemical gases; Background gas compensation: CO2 20ppm 0~2000ppm,0~100%Vol.
safe and reliable;
・Tolerance to extreme humidity and even liquid water; 0...50% Carbon Dioxide ±0.5% readings H2O 0.01ppm 0~10ppm,0~100%Vol.
・Modular design,can replace all functional modules on
・Low maintenance; Accuracy: 0...300g/m3 water content (Td=80°C) ±1%
site,easy maintenance; H2S 2ppm 0~20ppm,0~100%Vol.
・Preventive maintenance diagnosis; readings
・The heated optical surface prevents condensation. Power supply: Input range 18...36VDC ・Intelligent and easy to operate. HF 0.01ppm 0~1ppm,0~50%Vol.
・Stainless steel mesh filter device and optional porous Power waste: Less than 10VA HCL 0.01ppm 0~7ppm,0~50%Vol.
percolation PTFE filter make the optical probe dust-proof Analog output: 4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V, HCN 0.2ppm 0~20ppm,0~1%Vol.
and dust-proof. Moreover, the intelligent measurement output mode can be set freely
Maximum load: 500Ω NH3 0.1ppm 0~10ppm,0~100%Vol.
algorithm of PC68 can further reduce the impact of
Communication:RS485(Standard Matching)/RS232(Option- Technical Specifications CH4 10ppm 0~200ppm,0~100%Vol.
pollutants and give maintenance tips before the measure-
al Matching) Optical channel C2H2 0.1ppm 0~10ppm,0~100%Vol.
ment performance is affected. Relay contact length: ≤20m
・The TDL technology used by sensors is one of the most capacity: 24VDC,0.2A C2H4 1.0ppm 0~10ppm,0~100%Vol.
advanced technologies in today's market.The principle Response time:≤1s
Explosion-proof
of TDL is to measure the attenuation of laser beam in grade: Exd II CT6 (CI-PC68-1) Linear error: ≤1%FS
sample gas and adjust the wavelength of oxygen Protection level: IP66 (CI-PC68) Repeatability: ≤1%
molecule to a specific value to induce oxygen in laser. Range drift: ≤1% FS/half a year
Therefore,the measured attenuation is only for the atten- Maintenance Applications
uation of oxygen content passing through the beam. cycle: ≤2 times per year,clean optical window
Applications ・Detection of the concentration of O2 and CO in iron and
Calibration
steel metallurgy;
Technical Specifications Fermentation process monitoring,bioreactor,compost- period: ≤2 times per year
・Detection and analysis of CO in electric power,cement,
Scope of ing (treatment),gas generation,residual oxygen measure- Explosion-proof
environmental protection and other industries;
measurement: 0....25% oxygen ment,automatic inert sealing system,solvent tank,chemi- type: Exd II CT5
・Trace HCl and HF analysis in environmental protection,
Accuracy: ±0.2% oxygen (including noise,linearity cal/pharmaceutical reaction,biogas/landfill gas oxygen Protection level: IP66
and repeatability) chemical industry, etc.
monitoring,chemical,pharmaceutical,steel,environmental Analog output: 2-way 4-20mA output(isolation,maximum
Temperature drift: ±2% readings ・Detection and analysis of CO2 in coal chemical industry,
protection,food industry,etc. load 750Ω)
Stability: ±1% readings/year environmental protection,medical and other industries;
Zero drift: ±1% oxygen/year Analog input: 2-way 4-20mA input(temperature and pressure
・FCC flue gas detection and analysis;
Measured reaction time: 3 seconds compensation)
・Torch gas analysis;
Diffusion reaction Digital output: RS485/RS232/GPRS
time: T63/T90 Order Information ・Analysis of coke-burning flue gas in ethylene cracking
Relay output: 3-way output (24V,1A)
10 seconds/20 seconds without filter ・ Options and accessories:waterproof PTFE filter,aperture furnace;
Power supply: 24VDC,<10W
Stainless steel mesh filter 10 seconds/ 8 micron; ・Refinery acid gas analysis;
25 seconds Purge gas: 0.3MPa~0.8MPa Industrial Nitrogen and
・ With EPDM (ethylene propylene polymer) sealing ring; ・Trace gas detection in chlor-alkali industry;
Stainless steel mesh and PTFE filters ・ With Kalrez (fluororubber) sealing ring; Purified Instrument Air etc.
・Detection of synthetic ammonia gas.
30 seconds/70 seconds ・ With Kazrez O-ring; Environmental
Without pressure temperature: -30°C~60°C
・ 1/2 "NPT Pipeline Installation:8 Pin Joint M12 214806SP;
compensation: 0.8...1.2 bar-2% reading
・ Installation of sampling chamber wall:O.D.6mm pipeline Installation
Pressure drift: 1.2...1.4 bar-5% reading
Pressure gas accessories. mode: In-situ Installation

95 96
Optical gas analyzer Multicomponent gas analyzer

BT200 CI-PS10
Ozone analyzer Portable biogas analyzer
The BT200 ozone analyzer uses the characteristic CI-PS10 portable biogas analyzer is a biogas analyzer
that ozone has the maximum absorption degree in the specially developed by our company for biogas environ-
wavelength of 253.7nm ultraviolet light to detect the light ment.It takes micro-controller technology as the core,
intensity of ozone in the wavelength of 253.7nm ultravio- uses infrared and electrochemical sensors as measuring
let light,then converts the light intensity into ozone concen- units,and simultaneously measures the concentration of
tration according to the Beer-Lambert law,after good oxygen (O2),methane (CH4),carbon dioxide (CO2),hydro-
gen sulfide (H2S) in the sample gas.The analyzer has the
concentration tracing and instrument correction,the ultravio-
characteristics of intelligence,high precision,fast response
let absorption method can provide a fast,accurate and
and good stability.
stable and timely ozone concentration measurement.

Product Features Technical Specifications Product Features Technical Specifications


・Single-chamber single-beam UV photometer tion range or ± 1% of the full-scale concentration in the ・ It has the characteristics of intelligence,good stability, Hydrogen sulfide (H2S) detection:
・Ozone concentrations can be traced back to NIST verification range (in accordance with ISO/IEC17025 high reliability and long calibration cycle. Sensors: Electrochemical hydrogen sulfide sensor
international standards; and traceable to NIST SRP # 30); ・ At the same time,the concentration of oxygen,methane, Scope of
・Wide measurement range (0-20 vol.%) ・Warm-up time:<5 minutes carbon dioxide and hydrogen sulfide in mixed gases measurement: 0~10000ppm H2S
・With dynamic full range measurement mode ・Response time (T95):<30 seconds (low concentration were detected without interference. Accuracy: ±2%FS
model) or<10 seconds (medium concentration and high ・ The analyzer is suitable for biogas environment. Repeatability: ±1%FS
・Have 6 concentration units(ppbv,ppmv,vol.%,μg/m3, mg
・ Built-in micro printer can print current test data at any Stability: ±1%FS/7d
/m3,g/m3) concentration model)
time. Response time: T90<60s
・Front panel key can quickly switch measurement range ・Zero drift:automatic zero cleaning
・ The protection level of chassis reaches IP65. Analyzer:
and concentration unit ・Full-scale drift:±2% of full-scale concentration in the Charging power
・ The analyzer has built-in large capacity lithium batter-
・Backlit LCD display with white text on blue background measurement range ies,so the analyzer can be used not only for on-line supply: 85~264VAC,50/60Hz
(2 linesx20 characters) Simultaneous display of concen- ・Sampling flow:built-in 1.0-1.5 L/min suction pump analysis,but also as a portable device. Standby time: More than 8 hours (normal use)
tration,temperature and pressure ・Analog signal output:4–20 mA or 0–10 V Environmental
・Automatic temperature and pressure compensation ・Power:DC 12 V,1.5 A @ AC 100–240 V,50–60Hz temperature: 0~45°C
・Built-in suction pump ・Working environment temperature:0–40°C Technical Specifications Environmental humidity:Less than 80% RH
・Multiple output signals (RS232,4–20mA,0–10V) can be ・Working environment humidity:<90% RH (non-condens- Measurements: Gas intake
selected,with 4 self-diagnostic failure warnings. ing) Oxygen (O2) detection: Sample flow rate:400~600ml/min
・UV light source warranty period:2 years (20,000 hr@ Sensors: Electrochemical oxygen sensor Intake pressure: Atmospheric pressure ±10%(outlet should
Scope of be atmospheric pressure)
50% light decay rate);
measurement: 0~25.00% O2 Inlet and outlet
・Calibration period:1 year
Accuracy: ±2%FS connections: 1/4-inch NPT internal thread,stainless
Technical Specifications Repeatability: ±1%FS steel material
・Low-concentration model measurement range:front Stability: ±1%FS/7d Analyzer weight: Net weight is 5.15kg and about 10kg after
Response time: T90<60s packing.
panel keys can switch between 0–1,0–10, 0–100,0–1000
ppmv,user specified range, dynamic full range Applications Methane (CH4) detection: Cabinet size: L×W×H=305mm×270mm×144mm
Sensors: NDIR Non-dispersive Infrared (Double Packing box: L×W×H=470mm×410mm×315mm(Car-
・Measuring range of medium-concentration models:the Ambient air ozone concentration monitoring; process tail ton,subject to the actual product)
Beam) Measurement
buttons on the front panel can switch between 0-10, gas ozone concentration monitoring;ozone generator Scope of
0-100,01000,0-10000 ppmv,user-specified range,dynam- concentration monitoring;indoor air purification and waste measurement: 0~99.9% CH4
ic full range; gas treatment;drinking water purification and waste water Accuracy: ±2%FS
・Measurement range of high-concentration models:the treatment;medical sterilization and treatment;food clean- Repeatability: ±1%FS Applications
keys on the front panel can switch between 0–100, ing,disinfection,storage;agricultural irrigation,livestock Aqua- Stability: ±1%FS/7d
CI-PS10 analyzer is not only suitable for biogas indus-
0–1000,0–10000 ppmv,0–20 vol.%,User-specified range, culture,aquaculture;plastic and rubber aging test;industri- Response time: T90<15s
Carbon dioxide (CO2) detection: try,but also for petrochemical industry,natural gas,metal-
dynamic full range; al process;semiconductor process.
Sensors: NDIR Non-dispersive Infrared (Double lurgy,power electronics,mechanical manufacturing and
・Display screen:White text on a blue background,backlit
Beam) Measurement other industries.
LCD(2 linesx20 characters),showing concentration,tem-
Scope of
perature and pressure at the same time
measurement: 0~99.9% CO2
・Resolution:0.0001 ppmv@0–1 ppmv,0.001 ppmv@0–10 Accuracy: ±2%FS
ppmv,0.01 ppmv@0–100 ppmv,0.1 ppmv@0–1000 ppmv, Repeatability: ±1%FS
1 ppmv@0–10000 ppmv,0.001 vol.%@0–20 vol.%; Stability: ±1%FS/7d
・Accuracy:the greater of±1% of the reading in the verifica- Response time: T90<15s

97 98
Multicomponent gas analyzer Multicomponent gas analyzer

CI-XT683 CI-PU20
On-line explosion-proof Multicomponent flue
biogas analysis system gas analyzer
CI-XT683 on-line explosion-proof biogas analysis system CI-PU20 multi-component flue gas analyzer is devel-
is a biogas analysis system with explosion-proof perfor- oped for the complex flue gas environment.It uses
mance developed by our company for biogas environ- infrared sensor and electrochemical sensor as measur-
ment.It uses infrared and electrochemical sensors as ing unit,and simultaneously measures the concentration
measuring units,and simultaneously measures the concen- of sulfur dioxide (SO2),nitric oxide (NO),nitrogen dioxide
tration of oxygen (O2),methane (CH4),carbon dioxide (NO2),oxygen (O2),carbon monoxide (CO),carbon dioxide
(CO2),hydrogen sulfide (H2S) in the sample gas.The analy- (CO2) in the sample gas.The analyzer uses 7-inch color
sis system has the characteristics of intelligence,high capacitive touch screen as display and input window,
precision,fast response and good stability.Its shell is which is intuitive and easy to operate.
flameproof.It adopts Ex component flameproof sign Exd
II BT6Gb,which is the whole flameproof structure.
Product Features Technical Specifications Product Features Technical Specifications
・It has the characteristics of intelligence,good stability, Stability: ±1%FS/7d ・Intelligence,good stability,high reliability,long calibra- Stability: ±1%FS/7d
high reliability and long calibration cycle. Response time: T90<15s tion cycle,etc. Response time:T90<60s
・At the same time,the concentration of oxygen,methane, Hydrogen sulfide (H2S) detection: ・High-precision NOx measurement:The analyzer can Carbon monoxide (CO) detection:
carbon dioxide and hydrogen sulfide in mixed gases Sensors: Electrochemical hydrogen sulfide sensor measure the concentration of NO and NO2 separately. Sensors: Electrochemical sensor
were detected without interference. Scope of The exhaust gas of engine often contains fluctuating Scope of
・The analysis system is suitable for biogas environ- measurement: 0~10000ppm H2S NO2.In order to obtain the true NOx value,it is neces- measurement: 0~1000ppm CO
Accuracy: ±2%FS sary to measure the concentration of NO and NO2 Accuracy: ±2%FS
ment.
Repeatability: ±1%FS Repeatability: ±1%FS
・It can be used for explosive gases containing Class II C separately.
Stability: ±1%FS/7d
T6 and below and their mixing. Stability: ±1%FS/7d ・Alarm function:When the gas content deviates from
Response time:T90<60s
・Hazardous environment of area 1 and area 2 formed by Response time: T90<60s the alarm value,the alarm value can be set arbitrarily
Carbon dioxide (CO2) detection:
substances; Analyzer: within the full range. Sensors: NDIR Non-dispersive Infrared (Double Beam)
・Built-in micro printer can print current test data at any Analog output Measurement
time. signal: Four groups (corresponding to the concen- Technical Specifications Scope of
・The protection level of the chassis is IP64. tration of O2,CH4,CO2,H2S) can set the output Sulfur dioxide (SO2) detection: measurement: 0~30.0% CO2
mode freely. Sensors: Electrochemical sensor Accuracy: ±2%FS
4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V Scope of Repeatability: ±1%FS
Technical Specifications Alarm output: Four groups (for concentration alarm of measurement: 0~1000ppm SO2 Stability: ±1%FS/7d
Oxygen (O2) detection: O2,CH4,CO2 and H2S respectively), Accuracy: ±2%FS Response time:T90<15s
Sensors: relay contact Repeatability: ±1%FS Analyzer:
Electrochemical oxygen sensor
capacity: 24VDC,0.2A; Stability: ±1%FS/7d Power supply: 85~264VAC,50/60Hz
Scope of 0~25.00% O2
Communication:RS485(Standard Matching)/RS232(Option- Response time: T90<60s Alarm output: Quantity:6 groups (COM and NO)
measurement: ±2%FS
al Matching) Nitric oxide (NO) detection: Relay Contact Capacity:24VDC,0.2A
Accuracy: ±1%FS
Environmental Sensors: Electrochemical sensor Analog signal: Quantity:6 sets of output modes:free settings
Repeatability: ±1%FS/7d Scope of
temperature: 0-45°C 4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V
Stability: T90<60s measurement: 0~500ppm NO
Environmental Humidity:Less than 80% RH Load:less than 500Ω
Response time: Accuracy: ±2%FS
Intake pressure:Atmospheric pressure±10% (outlet should Communication:RS485 (Standard Matching)/RS232 (Optional
Methane (CH4) detection: Repeatability: ±1%FS
be atmospheric pressure) Matching)
Sensors: NDIR Non-dispersive Infrared (Double Stability: ±1%FS/7d Environmental
Beam) Measurement Explosion-proof
Response time: T90<60s temperature: 0-45°C
Scope of grade: Exd II CT6 Nitrogen dioxide (NO2) detection: Environmental humidity:less than 90% RH
measurement: 0~99.9% CH4 Sensors: Electrochemical sensor Intake pressure: Atmospheric pressure±10% (outlet should be
Accuracy: ±2%FS Scope of atmospheric pressure)
Repeatability: ±1%FS measurement: 0~500ppm NO2
Stability: ±1%FS/7d Accuracy: ±2%FS Applications
Response time: T90<15s Applications Repeatability: ±1%FS
Carbon dioxide (CO2) detection: Stability: ±1%FS/7d ・Flue gas analysis of industrial burners,on-line industrial
CI-XT683 analysis system is not only applicable to Response time: T90<60s engines,steam turbines and flue gas purification systems
Sensors: NDIR Non-dispersive Infrared (Double during commissioning,setting,optimizing or working
Beam) Measurement biogas industry,but also to petrochemical industry,natural Oxygen (O2) detection:
measurements;
Scope of gas,metallurgy,power electronics,mechanical manufac- Sensors: Electrochemical sensor
・Control and monitoring of statutory emission limits of
measurement: 0~99.9% CO2 turing and other industries. Scope of
exhaust gases;
Accuracy: ±2%FS measurement: 0~25.00% O2 ・Function comparison test of on-line emission measure-
Accuracy: ±2%FS ment instrument;
Repeatability: ±1%FS
Repeatability: ±1%FS ・Control and monitoring of gas in combustion chamber
or kiln in different processes.
99 100
Multicomponent gas analyzer Hydrogen sulfide analyzer

CI-PC251 CI-PC952/-1
Explosion-proof Explosion-proof
two-component analyzer hydrogen sulfide analyzer
CI-PC251 explosion-proof two-component analyzer The shell of CI-PC952/-1 explosion-proof hydrogen
is an infrared gas detection device based on the principle sulfide analyzer is flameproof.It adopts Ex component
of NDIR (non-spectral infrared) and the core of micro-con- flameproof sign Exd II C,which is the whole flameproof
troller technology.It has complete self-diagnosis function structure.It can be used in dangerous environment of
and monitors the working state of the instrument at any zone 1 and zone 2 formed by explosive gases and their
time.The measured background gas must be argon,oxy- mixtures containing class II C T6 and below.The instru-
gen,hydrogen and other gases without overlapping absorp- ment is a hydrogen sulfide detector based on electro- CI-PC952-1
tion peaks.The shell of the analyzer is flameproof.The chemical gas sensors.The digital processing technology
flameproof sign of Ex element is Exd II CT6,which is the
is used in the detector,including calibration,lineariza-
whole flameproof structure.It can be used in dangerous
tion,switching output control,current/voltage output,pa-
environments containing explosive gases and their mixtures CI-PC952
rameter setting and other functions.
of Class II C T6 and below.
Product Features Technical Specifications Product Features Technical Specifications
・Using NDIR (non-dispersive infrared measurement), the Alarm: Alarm point:2(CO and CO2 concentration ・With microprocessor as the core,it has good long-term 0-10V/1-5V,output mode can be set freely
sensor is not in contact with the measured gas,and the alarm) stability and high reliability. Load:less than 500Ω
poisoning phenomenon of the sensor will not occur. Relay Contact Capacity:24V DC,0.2A ・The electrochemical gas sensor is used as the measur- Environmental
・High stability infrared light source and strong anti-inter- Analog output ing unit with high accuracy and long calibration period. temperature: -10~45°C
ference filter make the analyzer stable for a long time. signal: Number:2 groups (corresponding to CO and ・With the latest touch key technology,it is easy to operate Environmental humidity:Less than 90% RH
・With microprocessor as the core,it has the characteris- CO2, respectively) and has a long service life. Sample flow
tics of intelligence,stability,high precision and long calibra- Output mode:4-20mA ・Menu lock switch:to prevent misoperation to change rate: 400-500ml/min(recommended 450ml/min)
tion cycle. Load:less than 500 the parameters of the detector and affect its normal Sample
・The front frame of the analyzer is covered with a piece Sensor life: More than 2 years (normal use) operation; pressure: Atmospheric pressure ±10% (outlet should
of toughened glass,which is not only beautiful,but also Analyzer life: More than 5 years (normal use) ・Data Storage:Supporting data storage of U disk and SD be atmospheric pressure)
has a good protective effect on the LCD screen and keys. Environmental card,data storage is large and convenient for users to Inlet and outlet: 1/4-inch NPT internal thread,stainless steel
・Menu lock switch:to prevent misoperation to change temperature: 5~45°C process and analyze data;Timing data storage inside material (standard 1/4-6 card-plastic joint)
the parameters of the analyzer to affect its normal opera- Environmental humidity:Less than 80% RH the instrument is convenient for users to quickly view Sensor life: More than 2 years (normal use)
tion; Sample flow test data; Instrument life: More than 5 years (normal use)
・Alarm function:When the gas concentration deviates from rate: 500-1000ml/min ・Alarm function:When the content of hydrogen sulfide Cabinet size: LXWXD=321 mmX200 mmX134.5 mm
the alarm value,the alarm value can be set arbitrarily within Sample deviates from the alarm value,the alarm point can be Installation
the full range. pressure: Atmospheric pressure± 10% (outlet should set arbitrarily within the full range. mode: Wall hanging type
be atmospheric pressure) Installation
dimensions: L*W=335 mm*180 mm
Technical Specifications Technical Specifications CI-PC952: CI-PC952:L*W*H=300*200*175mm
Detection NDIR,Non-dispersive Infrared (Double Beam) Applications Flowmeter:Selection
Range: 0~10000ppm H2S
principle: Measurement ・ Industrial control; CI-PC952-1 : CI-PC952-1:LXWXH=375X315X179mm
Resolving power: 0.1ppm
Scope of ・ Petroleum exploration; Explosion-proof Level:Exd II CT6 (Certifica-
Accuracy: ±2%FS
measurement: 0~10.0% CO,0~30.0% CO2 ・ Air quality monitoring; tion)
Repeatability: ±1%FS
Accuracy: ±2%FS ・ Biogas analysis;
Stability: ±1%FS/7d
Repeatability: ±1%FS ・ CO (Ar/N2) detection in industrial fluid welding process,
Response time: T90<35s(0~20ppm)
Zero drift: ±1%FS/7d etc.
Recovery time: <60s
Range drift: ±1%FS/7d
Protection level: IP64 Applications
Response time: T90<15s (500ml/min)
Display
Order Information Measurements: On-line
・ Gas connection mode: Calibration cycle: One year (recommendation) ・Ocean operations;
resolution: 0.1%
A,6 hose connection (standard); Measuring ・Oil and gas drilling operations;
Measurements: online
B,1/4'-6 stainless steel jacket connection; instrument weight: Net weight 5.0 kg,about 15 kg after ・Where hydrogen sulfide gas often occurs;
Calibration
C,1/8'-3 stainless steel jacket connection; packaging ・Metallurgical,petrochemical,chemical,coking,gas,phar-
cycle: One year (recommended)
・ Filters:CI-GF2800,AF2000; Power supply: 24V DC maceutical,sewage;
Monitor: 128*64 LCD screen
・ Gas composition and measurement range under test; Power waste: Less than 15VA
Key: Four keys (touch keys) ・Deal with many special industries and fields.
・ The main components,impurities and sulfides of the Communication: RS485(Standard Matching)/RS232
Explosion-proof
measured gas. (Optional Matching)
grade: Exd || CT6
Alarm: Alarm point:1
Protection level: IP65
Instructions Relay Contact Capacity:24VDC,0.2A
Power supply: 85~264VAC,50/60Hz
Analog output
Power consumption of
Principle:See page 89 of this sample book. signal: Group 1,4-20mA/0-20mA/0-1V/0-5V/
analyzer: Less than 20VA

101 102
Water quality analyzer Water quality analyzer

61200 61101
Portable dissolved On-line dissolved oxygen
oxygen analyzer gas analyzer
This portable dissolved oxygen analyzer uses Dextens This online analyzer complements Dextens oxygen
oxygen sensor and is designed for off-line or laboratory sensor.It can continuously monitor trace oxygen concen-
measurements.In stainless steel chamber,this instru- tration and temperature in gas or liquid on-line.
ment is ideal in the strict environment of beer brewing Man-machine friendly type:Each parameter can be
process.It can also be used in low-end measurement in set by itself according to measurement conditions and
other industries.Both in the dissolved state and in the
operation needs.
gaseous state,it can react quickly and measure accurately.

Product Features Technical Specifications Product Features Technical Specifications


・The intake pipe of the instrument is easily connected to DO unit: ppm,ppb,mg/l,resolution 0.01 ppb,%--,ppm,kPa ・Man-machine friendly type:each parameter can be set Gaseous display
the measured gas source,and the sample gas enters Gaseous unit: resolution 0.01ppm by itself according to measurement conditions and unit: Resolution 0.01 ppb%-ppm,kPa
the sensor chamber of the instrument and contacts the DO range: 0.1ppb~200ppm operation needs; Measuring
sensor sensing film. Gaseous ・The window software can store the measurement results. concentration of
・Large display screen,continuous real-time display of range: 0.5ppm(v/v)~100% liquid oxygen: Resolution 0.01 ppm
・The stored results can be downloaded to the computer
concentration and temperature; Induction
through RS232 interface. 0.1ppb-200ppm
・The concentration ranges from 0.01 ppb to 100 ppm in Membrane
・This instrument is easy to install and can give on-line Gaseous oxygen
dissolved oxygen and from 0.5 ppm to 100% in gaseous Model: 82952,82956,82935
oxygen. Data upload: Automatic or manual data storage single-point measurement results in a few minutes. concentration
・Keyboard setting system functions and Settings,menu- air calibration or user arbitrary concentration gas ・Large LCD displays can continuously display real-time measurement: 0.5ppm (v/v)–100%
driven software,display time at the same time formulation measurement results and temperature. Film type: 82952,82956,82935
・The window software can store the measurement results. Calibration: Direct calibration ・The concentration shows that the unit liquid is from Hot cutoff: Factory Settings+40°C/140°F,Software
・The stored results can be downloaded to the computer Data output: RS232 0.01 ppb to 100 ppm and the gas is from 1.0 ppm to 100%. Adjustable
through RS-232 interface.In order to prevent arbitrary Sensor ・Function screen buttons and menus can help users Calibration: Single point air calibration and direct
changes and calibration settings,password protection selection: Oxygen sensor 51101 quickly set the instrument; calibration
is adopted. ・Real-time display; Alarm output: High/low or high/high alarm-125 VAC/
・Stainless steel structure,ideal choice for measurement 20 VDC
・The software guides the sensor calibration step by step.
under strict environment;
・One-point air calibration or user-specified concentra- Data output
・Waterproof grade IP65.
tion calibration; Communication
・In order to prevent arbitrary changes and calibration Interface: RS 232/RS 485
Measure settings, password protection is adopted. Sensor selection: Oxygen sensor 51101
Induction Membrane Model 82956 82952 82935 ・Stainless steel structure,ideal choice for measurement
Measurement range DO2 0.1ppb~20ppm 1ppb~100ppm 10ppb~400ppm under strict environment;
Measurement range PO2 0~4 bars 0~2bars 0~10bars ・Waterproof grade IP65.
Liquid velocity 180ml/min 50ml/min 25ml/min
Linear flow 200cm/sec 30cm/sec 20cm/sec Applications
Gaseous flow rate 0.005~3l/min 0.005~3l/min 0.005~3l/min ・On-line;
At 25°C,the measurement is achieved. 7.2sec 38sec 2.5min Technical Specifications ・Application of liquid and gaseous measurements;
Result 90% reaction time Power supply: 85-264VAC,50/60Hz ・Packaging production;
Accuracy 1% Absolute Zero and Low Drift of Measured or Minimum Value Power waste: Less than 20VA ・Semiconductor industry;
Working ・Power industry;
・Pharmaceutical and chemical industries.
Technical Specifications temperature: -5 ̄50°C
Shell: Stainless steel,IP65/Nema4X
Power supply: 5V DC voltage input,rechargeable battery
Weight: 3.0 kg
Operating Applications
conditions: 0°C to 45°C/32°F to 113°F Size: 230mmx180mmx75mm
Shell: Stainless steel,IP65/Nema4X,spraying Offline,laboratory;Dissolved state and gaseous dual applica- Display data: Temperature,concentration,time,film
Weight: 3.4 kg tions;Packaging production;Semiconductor industry;Boil- type
Size: WxHxD=250mmx180mmx180 mm er industry;Pharmaceutical and chemical industry. Liquid display unit: ppm,ppb,mg/l

103 104
Industrial process Industrial process

CI-XT100-B CI-XT300
Coke oven gas analysis system On-line monitoring system
for CDQ coke oven cycle
CI-XT100-B zero emission coke oven gas on-line CI-XT300 CDQ coke oven cycle on-line monitoring
oxygen analysis system is designed for on-line continu- system adopts explosion-proof treatment,which meets
ous detection of oxygen content before and after electric the requirements of CDQ cycle gas explosion-proof opera-
coke collector.It integrates machinery,electricity and instru- tion.The sample gas is sampled by direct sampling or
ment,combines advanced laser oxygen measurement pumping sampling (switchable),and then the corrosive
technology with sampling pretreatment,and fully purifies components,dust and impurities in the sample gas are
tar,coal dust,water vapor,naphthalene,hydrogen sulfide removed by the pre-processor and sent to the instrument
for analysis.The pre-treatment of the system is regularly
and other substances in coke oven gas through interna-
blown back and cleaned by the automatic control of PLC,
tional advanced technologies and equipment such as
which ensures the service life of the instrument.At the
isobaric differential water washing,two-stage condensa-
same time,the maintenance workload of the instrument
tion,water-sealed heat exchange dewatering and steam-wa- is greatly reduced.
ter separation.The long-term and stable operation of the Technical Specifications Technical Specifications
whole system is ensured by the treatment,and the oxygen Product Features
Alarm: 1-way alarm output(analyzer failure alarm) System power
content in the sample gas is measured by the laser ・Sampling uses high temperature and high dust plug-in
oxygen analyzer CI-385. consumption: Less than 2KW
Relay contact filter sampling probe,high precision filter is used in the
24VDC,0.2A Alarm: 1-way alarm output
capacity: filter device,high temperature resistance,corrosion
Signal output: A group of 4-20 mA outputs correspond resistance,filtering accuracy as high as 0.5um; Relay contact
to O2 ・Sampling tube adopts integrated anti-corrosion heat capacity: 24VDC,0.2A
Product Features Signal output: Four groups of 4-20 mA outputs corre-
Environmental tracing pipeline,which has good heat tracing effect and
・The system analysis instrument is imported from 0-45°C low maintenance. spond to CO,CO2,H2 and O2,respectively.
temperature:
Germany.The measuring principle is tunable diode Environmental humidity:Less than 80% RH ・It has a unique back-blown control system,which has a Environmental
laser absorption spectroscopy (TDLAS).Polymer filter high back-blown effect and can adapt to a higher dust temperature: 0-45°C
Intake pressure: Steam injection sampling at negative and
is used outside the instrument analysis room,which micro-positive pressures concentration gas sample. Environmental humidity:Less than 80% RH
can completely filter moisture and corrosive impurities, Sample flow rate: 4-6L/min ・The condenser adopts eddy current refrigeration technol- Intake pressure: Use of suction pumps at negative and
and effectively improve the testing accuracy and service ogy,which has the characteristics of stable perfor- micro-positive pressures
Inlet and outlet
life of the analyzer. mance,long service life and maintenance-free. Sample flow rate: 4-6L/min
interfaces: Φ25Clamp locking mode
・The main components are all imported,the sample gas Inlet and outlet
・The sampling probe of the system has built-in high-pre- Analyzer life: More than 5 years (normal use)
pipeline is fully anti-corrosion,and the hardware config- interfaces: G1/4 Internal Thread Interface
cision filter,which has the characteristics of strong Installation mode: Base expansion screw fixation
uration is high-grade. Analyzer life: More than 5 years (normal use)
corrosion resistance,high filtering accuracy,long mainte- Circuit structure: Applied in low explosion-proof or non-ex- ・Decentralized design technology is adopted to facilitate
plosion-proof occasions Installation mode:Base expansion screw fixation
nance period and convenient maintenance. installation,maintenance and overhaul.
System warranty Circuit structure: Applied in low explosion-proof or non-ex-
・Dual-loop sampling tube has the advantages of conve- ・There are professional team of service engineers,
12 months plosion-proof occasions
nient installation,strong corrosion resistance and self- period: reasonable selection of sampling points,installation
Calibration of System warranty
heating while sampling. technology of probe and on-site operation technology. 12months
analyzer: It is suggested that one calibration should period:
・The system pretreatment includes multiple water removal These rich professional experiences are the distinct
be carried out once a year,and one Calibration of
processes of water washing,water cooling,separation, and indivisible technical characteristics of the device.
standard gas and high purity nitrogen analyzer: It is suggested that three or four standard
re-water cooling and re-separation,and then the sample System size: gases and high purity nitrogen should
should be prepared for each calibration
gas is supplied to the analyzer for analysis to ensure be prepared for each calibration of zero
the use of the analyzer and prolong the service life of
zero point and range point. Technical Specifications and range points once a year.
System size: D*W*H=1530mm*420mm*2280mm
the devices in the system using explosion-proof and Measurement CO: 0-10.0%CO Housing
Housing
anti-corrosion design,which can fully meet the user's components and CO2: 0-20.0% CO2 dimensions: D*W*H=1400mm*650mm*2100mm
dimensions: D*W*H=3000mm*3000mm*3000mm
requirements. ranges: H2: 0-10.0% H2 Installation
Installation
O2: 0-25.0% O2 dimensions: D*W*H=3000mm*3000mm*2500mm
dimensions: D*W=1466mm*366mm (expanding screw)
Detection principle: CO—NDIR,Non-dispersive Infrared D*W=1300mm*550mm (expanding screw)
Packing box: Wooden box packing
Technical Specifications (Double Beam) Measurement Packing box: Wooden box packing
System weight: About 300 Kg
CO2—NDIR,Non-dispersive Infrared System weight: About 800 Kg
Measurement components and ranges: 0-25.0% O2
(Dual Beam) Measurement
Detection principle: Tunable Semiconductor Laser Diode
H2-Thermal Conductivity Sensor
Absorption Spectrometry (TDLAS)
System power
Applications O2-electrochemical gas sensor Applications
System power
supply: DC24V 10W Coking plant - electric tar trap intake or outlet can be used. Coking plant-electric tar trap intake or outlet can be used.
supply: 220VAC±10% 50/60Hz

105 106
Industrial process Industrial process

CI-XT800 CI-XT6003C
On-line monitoring system Brazing furnace on-line analysis
for carbon dioxide recovery system for multi-point inspection
The gas analysis system(hereinafter referred to as CI-XT6003 system adopts anticorrosive and protec-
the system) is a process analysis instrument(such as tive treatment,which meets the requirements of brazing
CO2, O2 analyzer) and a sampling pretreatment device furnace production line.The system takes sample gas by
and its subsidiary application support part(standard gas). suction pump,and then filters the dust from sample gas
Through on-the-spot investigation and detailed under- and sends it to the instrument for analysis.The system
standing of on-site process and working conditions,the can expand the sampling port according to the needs of
correct matching and reasonable combination system
the field.At the same time,the system has the function of
realized by the system design can make the analyzer well
adapt to the special and complex process conditions of pre-pumping the sampling points and realizes seamless
the tested sample gas.The system can automatically, docking in the process of cyclic detection.This unique
continuously, accurately and reliably analyze the content design.The real-time oxygen concentration in the brazing
of gas (such as CO2,O2) in sample gas. furnace can be detected in time and fed back to the user
Technical Specifications to ensure the welding quality of the product,as well as the Technical Specifications
Technical Specifications service life of the instrument,which greatly reduces the
reaction rate Corrosive: There is no strong corrosive component maintenance workload of the instrument. micro-positive pressures
The lag time (T10) and rise time (T10-T90) of the analyzer in the gas sample. Sample flow rate: 4-6L/min
Lag time: T10≤5s Working conditions Inlet and outlet
Rising time: T10~T90≤2s Environmental interfaces: G1/4 Internal Thread Interface
Product Features
Delay time and rise time of the system temperature: 5~45°C Analyzer life: More than 5 years (normal use)
Lag time: T10≤30s Relative humidity: ≤85% ・ The sampling probe of the system has built-in high-pre- Installation mode: Base expansion screw fixation
Rising time: T10~T90≤2s Power supply: 220 VAC±10% 50/60Hz cision filter,which has the characteristics of strong corro- Circuit structure: Applied in low explosion-proof or non-ex-
Main Technical Indicators Power sion resistance,high filtering accuracy,long maintenance plosion-proof occasions
Zero drift: ≤±1% FS/7d consumption: ≤0.5KVA period and convenient maintenance. System warranty
Range drift: ≤±1% FS/7d Environmental ・ The automatic control unit of the system PLC enables period: 12months
Repeatability: ≤0.5% atmosphere: The environment does not contain explo- the system to complete the functions of automatic pre-ex- Calibration of
Load: ≤750Ω sive and corrosive atmosphere and has traction,automatic switching of sampling port,automatic analyzer: It is suggested that three or four standard
Output signal: 4~20 mA DC good ventilation conditions. test,automatic back blowing,automatic sewage discharge gases and high purity nitrogen should
Applicable working conditions Ambient pressure: Elevation below 2500 m and fault alarm,effectively reducing the labor cost for be prepared for each calibration of zero
Gas sample No direct sunlight radiation users. and range points once a year.
temperature: ≤60°C No strong electromagnetic interference System size: D*W*H=1200mm*650mm*1600mm
Gas sample pressure No mechanical vibration Housing
and fluctuation range:-50~100KPa Air velocity: ≤0.5m/s dimensions: D*W*H=2000mm*2000mm*2500mm
Gas sample flow: ≤300L/h Working position: Horizontal Technical Specifications Packing box: Wooden box packing
Gas dust Quality System Certification:ISO 9001:2008 Standard System weight: About 120 Kg
Measurement components and ranges: 0-1000ppm O2
concentration: ≤2000g/m3
Arbitrarily scalable or configurable
Detection principle: Electrochemical gas sensor

System Flow Diagram


System power Applications
The temperature in the analysis room must be controlled at 5-40 °C supply: 220 VAC±10% 50/60Hz
Instrument emptying System power ・ Automobile manufacturing-brazing furnace;
Programmable switch Code list consumption: Less than 50VA ・ It can be widely used in brazing furnace,air separation
Bypass vent control CI-BR90
Serial number Code name content Alarm: 1-way alarm output and liquefaction,such as the measurement and control
Micro oxygen
of oxygen concentration in pressure swing adsorption
4-20mA output
meter 1 A CO2 Analysis instrument Relay contact
2 QH-1 Air heated vaporizer (PSA) nitrogen making equipment.
capacity: 24VDC,0.2A
Process piping

Sample inlet
3 YV10 Cryogenic ball valve ・ Chemical process;
4 YV12 Low temperature needle valve Signal output: A group of 4-20 mA outputs correspond to ・ Protective gas in high temperature sintering furnace
Membrane filter
5 FIG1
O2 respectively. such as magnetic material;
Calibration port 6 FIG3 Sample gas filter
7 VABF Pressure relief valve
Environmental ・ Protective gases in the electronic industry;
External sample gas 8 L1 Alarm flowmeter temperature: 0-45℃ ・ Glass, building materials industry,etc.
Sampling port 9 L2 Bypass flowmeter Environmental humidity:Less than 80% RH
10 WAY1,2 Selection valve
11 QS10 Gas liquid separator Intake pressure: Use of suction pumps at negative and
12 HC Sampling probe
13 GBT Standard gas

107 108
Industrial process Industrial process

CI-XT6400 CI-XT62B
On-line analysis system Heat treatment furnace-controllable
for gas generator atmosphere analysis system
CI-XT6400 series pretreatment system is one of the The CI-XT62B gas analysis system is based on the
pretreatment systems independently developed by our characteristics of process gas sample conditions (high
company.The system adopts anti-corrosion and explo- temperature and water content) of silicon steel sheet
sion-proof treatment mode,which meets the require- heat treatment furnace. The principle of component
ments of chemical explosion-proof production line.The analysis is to use measured water content data and
sampling method of air extraction is adopted to send the indirectly measured dry sample composition data (after
sample gas sampling filtering dewatering dedusting to dewatering). The corresponding real-time measurement
the instrument for analysis,which ensures the service life parameters are converted by real-time acquisition of PLC,
of the instrument and greatly reduces the maintenance so the whole set of online gas analysis is based on the
workload of the instrument. conversion algorithm.This system can realize double
parameter display.
Product Features Technical Specifications The pretreatment technology is designed systemati- Technical Specifications
cally for the gas sample condition of the silicon steel
・The sampling probe of the system has built-in high-pre- Inlet and outlet sheet heat treatment furnace.The correct matching and temperature: 0~45°C
cision filter,which has the characteristics of strong corro- Interfaces: G1/4 Internal Thread Interface reasonable combination are realized,so that the analyti- Sample pressure:Micro-negative pressure,positive pressure or
sion resistance,high filtering accuracy,long maintenance Analyzer life: More than 5 years (normal use) cal instrument and pretreatment device can well adapt to atmospheric pressure(according to different
period and convenient maintenance. Installation the process condition.
configurations of pressure relief valve or
・The probe can automatically switch sampling and testing mode: Base expansion screw fixation pump)
with the use of delay relay.
Circuit Product Features Shape size: DxWxH=600x600x1700(including base)
・The self-constant temperature sampling tube has the
structure: Applied in low explosion-proof or non-ex- Analyzer (optional according to working condition)
characteristics of convenient installation,strong corro- ・High temperature and humidity high temperature
sion resistance and constant temperature. plosion-proof occasions Humidity analyzer
sampling probe is used for sampling,and high precision
・The automatic control unit of the system delay relay System Range: -80~+60°C (optional)
alloy filter is used for filtering device,which is high
enables the system to complete the functions of automat- warranty period: 12months Sensor manufacturers: CHANGAI
temperature resistant and corrosion resistant,and the
ic test and automatic back-blowing,which effectively Calibration of Detector quantity:Capacitive polymer film
filtering accuracy is as high as 0.3u.
reduces the labor cost for users.The internal devices of analyzer: It is suggested that three or four standard ・ Micro-oxygen analyzer
the system are designed with explosion-proof and Sampling tube adopts integrated anti-corrosion electric
gases and high purity nitrogen should be Range: 0-10/100/1000PPm%O2
anti-corrosion,and can meet the user's requirements. heat tracing closed-loop temperature control pipeline,
prepared for each calibration of zero and Sensor manufacturers: USA
which has good heat tracing effect and prevents moisture
range points once a year. ・ Detector quantity: Electrochemistry
loss of sample gas.
System size: D*W*H=600mm*600mm*1750mm Hydrogen analyzer
・Water detector,high temperature and humidity sensor
Technical Specifications Housing Range: 0-60% H2
with polymer permeable film;
dimensions: D*W*H=2000mm*2000mm*2500mm Sensor manufacturers: USA
Measurement components and ranges: 0-25.0% O2 Compressor refrigeration technology can quickly remove
Packing box: Wooden box packing Detector quantity: Thermal conductivity
Can be extended according to user needs ・moisture in sample gas and prevent the loss of other
System weight: About 100 Kg
Detection principle: Magneto-mechanical Technology components in sample gas.

System power The main components are all imported,and the hardware
supply: 220 VAC±10% 50/60Hz ・configuration is high-end. Applications
System power Decentralized design technology is adopted to facilitate
Applications installation,maintenance and overhaul.
・ High quality silicon steel heat treatment furnace;
consumption: Less than 50VA ・ Protective gas testing in electronic industry.
Alarm: 1-way alarm output ・ Oxygen measurement in coking plant - gas branch pipe; There are professional team of service engineers,reason-
Relay contact ・ It can be widely used in air separation,liquefaction and able selection of sampling points,installation technolo-
capacity: 24VDC, 0.2A chemical process. gy of probe and on-site operation technology.These
Signal output: A group of 4-20 mA outputs correspond to ・ Protective gas in high temperature sintering furnace rich professional experiences are the distinct and indivisi- Order Information
O2 respectively. such as magnetic material; ble technical characteristics of the device.
・The non-explosion-proof design of this product is
Environmental ・ Protective gases in the electronic industry;
forbidden to be used in explosion-proof occasions
temperature: 0-45°C ・ Glass, building materials industry, etc.
Technical Specifications (explosion-proof needs to be customized);
Environmental humidity:Less than 80% RH ・Before ordering,please communicate with the company's
Intake pressure: Use of suction pumps at negative and System power supply: AC220V 50HZ technicians in detail.Only when the working conditions
micro-positive pressures Signal output: 4~20mA(RS485 Communication Matching) are known clearly,can the product achieve the best use
Sample flow rate: 4-6L/min Environmental effect.

109 110
Industrial process Mass flowmeter

CI-XTPC68 CI-SM80
On-line oxygen analysis General flow mass
of explosion-proof centrifuge instrument (insertion)
CI-XTPC68 centrifuge explosion-proof on-line oxygen Differential pressure flow measurement technology
analyzer is designed for centrifuge production process based on pitot tube principle is a commonly used method
conditions (its gas-liquid components are complex and in industry.It conforms to international standards (since
micro-dust) characteristics.Sample gas pretreatment using 1929).It has solid basic components,pure mechanical
organic miscible method can effectively treat a variety of structure,no movable parts, stable signal,high reliability
weak acid,alkali organic gases and organic particulates.The and long-term measurement accuracy.The flowmeter
automatic circulation control of solution in solvent cham- integrates temperature,pressure and flow measurement
ber and solvent tank is realized.At the same time,it also sensors,which can measure actual flow and standard flow
realizes the auxiliary action function control of pipeline without installing flow accumulator,temperature sensor
anti-blockage automatic cleaning and abnormal liquid and pressure transmitter,thus greatly saving installation
level stop protection;users can set the working parame- and maintenance costs.
ters of the system;the whole set of pretreatment devices Technical Specifications Product Features Technical Specifications
are integrated in a flameproof cabinet to realize two-zone temperature
explosion-proof occasion. Dew point temperature of ・The lower limit of gas measurement can be up to 2m/s Connector: 2x5-pin M12,Female
gas sample: Below normal temperature for a highly sensitive differential pressure sensor. Display: 2.8"IPS Ultra-Wide View LCD Screen with
Gas sample flow: ≤1.5L/min ・The integrated pressure and temperature sensor can Capacitive Touch
Product Features Gas dust concentration:≤ 20mg/m3 monitor the fluid pressure and temperature in real time. Data recording: 10,000,000 ecording points
Corrosive: ≤ 5000PPm ・The innovative online automatic calibration function Heating function: 18…30 V/24W@24V
・Gas analyzer detection principle:electrochemical or laser
Gas sample pressure and can compensate the temperature and pressure effect Normal
principle(choose Option A and Option B),can adapt to
fluctuation range: -20KPa~+20KPa in real time. measurements: 18…30V/6.5W
different complex working conditions;
Environmental ・Innovative anti-condensation technology; Working
・The pretreatment unit is designed with Perfluorinated
temperature: 5~45°C ・Resistance to particulate pollution,oil vapor and most temperature: -20…+60°C
material,which has super corrosion resistance and
Relative humidity: ≤85% chemicals; Medium
durability.
Power supply: 220 VAC 50 Hz ・Fully isolated electrical structure eliminates interfer- temperature: -40…200°C
・Sample gas treatment adopts organic miscible
Power consumption: ≤200VA ence thoroughly. Flow range
method,which can deal with a variety of weak acid and
Environmental ・2.8"IPS ultra-wide viewing angle LCD screen with capaci-
alkali organic gases. DN ID (mm) Min flow (Nm3/h) Max flow (Nm3/h)
atmosphere: The environment does not contain tive touch;
・The system adopts the automatic solvent circulation 25 25 17 388
explosive and corrosive atmosphere, ・No movable parts, low pressure loss;
control system to effectively guarantee the sample gas
and has good ventilation conditions. ・Insertion type,can be adapted to different pipe diame- 32 32 29 637
handling capacity.
Ambient pressure: Altitude below 2500m ters and can be installed on-line without stopping gas. 40 40 45 996
・Intelligent and clean control system is used to prevent
Air velocity: ≤0.5m/s ・With data recording function,10,000,000 recording
pipeline blockage,which can effectively improve the 50 50 71 1767
Working position: horizontal points;
stability of the system by more than 90%. 65 65 120 2986
Purge nitrogen: ≥0.5MPa ・With Bluetooth function,it can configure sensors and
・The integrated explosion-proof design can be used in
Compressed air: ≥0.5MPa transmit data wirelessly. 80 80 181 3981
the explosion-proof situation of zone 2.
・Support:4-20mA,RS485 and another signal output; Explosion-proof grade:Exd || CT6 100 100 282 6220
・Super high cost performance ratio. Technical Specifications 125 125 441 9719
Applications 150 150 636 13995
Flow measurement
・ Monitoring of oxygen content in centrifuges in pharma- 200 200 1131 22619
Technical Specifications Scope of measurement: 10…300 Nm/s
ceutical industry;
Measurement accuracy: +/- (1% reading+0.3% full range) 250 250 1767 35342
・ Monitoring of oxygen content in centrifuge in chemical
The lag time (T10) and rise time (T10-T90) of the analyzer Medium: Dry/wet air and non-corrosive gases 300 300 2544 50893
industry;
Lag time: T10≤10s Reference conditions: 0°C,1013.25 mbar-DIN1343
・ Monitoring of oxygen content in centrifuge in fertilizer
Rising time: T10~T90≤30s (Editable)
industry; Applications
Delay time and rise time of the system pressure measurement
・ Monitoring of oxygen content in centrifuges in food
Lag time: T10≤30s Scope of measurement: 0…16 bar Pitot tube differential pressure flowmeter is widely used
industry;
Rising time: T10~T90≤60s Measurement accuracy: 0.5% full range in industrial process,chemical industry and petrochemical
・ Monitoring of oxygen content in centrifuge in pesticide
Zero drift: ≤±1% FS/7d temperature measurement industry.
industry.
Range drift: ≤±1% FS/7d Scope of measurement: -40…200°C ・ Chimney gas measurement;
Repeatability: ≤0.5% Order Information Measurement accuracy: 0.5°C ・ Nitrogen and hydrocarbon measurements;
Load: ≤750Ω Analog output(standard) 4…20 mA/Pulse output ・ Gas measurement of heating furnace;
・ No direct sunlight radiation;
Output signal: 4~20 mA DC Digital output(Standardization)RS485,MODBUS RTU protocol ・ Oxygen and torch gas measurements;
・ No strong electromagnetic interference;
Sampling temperature of sample gas: Normal atmospheric Wireless output(optional): Bluetooth connectivity ・ Application data of soot blower.
・ No mechanical vibration.

111 112
Compressor condenser Filter

CI-R300P/B CI-GF2600/2800
Series condenser Filter
CI-R300P/B series two-channel gas condenser is an CI-GF2600/2800 can replace the filter core quickly.
efficient dehumidifier for compressor refrigeration.It is Its superior sealing,rapid displacement and simple and
mainly used in the pretreatment device of various gas easy to understand operability make it applicable to all
analyzers.It can improve the measuring accuracy of the kinds of sample gas pretreatment to remove impurities
analyzer,reduce the corrosive effect of gas on the analyz- such as water,dust and flux in sample gas.The filter is
er and pipeline,and greatly improve the service life of the made of plexiglass sleeve,which can check the working
analyzer.It is also applicable to other occasions for drying condition of the filter element intuitively.If a layer of filter
sample gas. substance,such as flux and dust,is found on the surface
condenser of the filter element,the filter element can be changed.

Product Features Technical Specifications Product Features Dimension map


・Simple installation and beautiful appearance; Sample gas output dew ・Efficiency:Particulate matter such as dust can be removed CI-GF2600
・The principle is reliable.The compressor is cooled by point: ±4°C through the outer cylinder of high molecular polyeth- 1 Installation Opening 2 Size Diagram of Filter
refrigeration,the specially designed heat exchanger Sample gas input is ylene filter core,and impurities in sample gas can be Dimension Diagram
maximizes the cooling sample gas,and the compres- stable: ≤80°C further removed by activated carbon.
sor runs uninterruptedly to avoid the influence of frequent Sample gas input dew ・Rapid displacement:There is no dead angle in the filter,
start-up on the compressor life.
point: ≤80°C and all parts are well connected,which can quickly displace
・In order to ensure the high dehydration efficiency of
Sample gas flow the air inside the filter.
sample gas after dewatering through primary cooling,
the sample gas is cooled and dewatered again,and the range: ≤300L/H ・Easy to observe the use of filters:transparent tempered
dewatering efficiency is as high as 97%. Condenser material: Glass glass is used as the window outside the filter,which can
・Using energy neutralization control theory and intelli- Working environment be very intuitive to see the use of the filter element;
gent PID to regulate the temperature of heat exchang- temperature: -5°C~+45°C ・Easy to replace the filter element:the filter element is an
er, the temperature of heat exchanger is constant at Dehumidification independent structure,which is very convenient to replace.
the set temperature,and the control precision is (+0.2 C). channel: 2 way
・Fault alarm output,when the temperature of heat Sample gas interface
exchanger is higher than the set value,the output alarm size: Φ6
signal can be a switch signal, or an active output (220V Technical Specifications
Drainage interface
AC) control sampling pump or valve to maximize the
size: Φ6 Functions: Removal of water,rosin,organic matter,etc.
protection of analytical instruments;
Installation mode: CI-R300B:Wall-mounted Material of filter
・Environmental protection and pollution-free,compres
sor refrigerant is R134a,ozone pollution-free,green CI-R300P:19-inch standard cabinet element: Imported Polymer Polyethylene and Activated
environmental protection,refrigeration effect is good; Shape size: CI-R300B:310X300X330mm Carbon CI-GF2800
・Compressor is the only mechanical component.In order CI-R300P:485X340X222mm Filtration 1 Installation Opening 2 Size Diagram of Filter
to prolong the service life of the compressor and avoid Weight: 14kg diameter: 10um Dimension Diagram
the impact of vibration system caused by repeated Power Supply: 220V±10%,50Hz Working
start-up and start-up,the compressor always runs. Power: 350VA pressure: -1~1kPa
・Measure and control cohabitation point,accumulate Alarm output: Relay Contact Capacity 220VAC or Temperature
years of experience,temperature measurement and 24VDC 2A range: 5~45°C
control should cohabit point,show the real state of work; Preheating time: Less than 15min Air intake: 1/4"NPT,adapter can be configured according
・The distance between the measuring and controlling
to need,lower end is intake port
points and the steam-water separator is only 4 mm.
・The measuring and controlling points are as close as Air outlet: 1/4"NPT,can be configured as needed,the upper
possible to the working area to reduce the influence of end is the outlet.
gradient difference on the measuring and controlling
accuracy.

113 114
Filter Filter

CI-GF2900 AF-1000
Activated carbon filter Filter
(corrosion resistance)
The filter can intercept and adsorb organic residues,
dust and impurities in the measured gas,and is one of the
important equipment for sample gas pretreatment.
The service life of the filter is affected by the flow
rate of the gas into it.Within the prescribed flow range,the
larger the flow rate,the faster the response time of the
analyzer.But at the same time,the service life of the filter
will be shortened.The user should adjust the sample flow
rate according to the actual situation to achieve the
balance between the response time of the instrument and
the replacement time of the filter core. Dimension map Technical Specifications Use Attention
CI-GF2900 1.When there are water droplets in the filter, the
Filler: Activated carbon
Product Features 1 Size Diagram of Filter Functions: Removal of water,rosin,organic matter,etc. activated carbon has been absorbed and saturated, so
Air intake: φ6 connector,The reverse end of the arrow is AF1000 must be replaced immediately.
・No dead zone,fast replacement;
the intake port. 2. AF1000 must be replaced immediately when a
・Excellent sealing performance;
Exhaust large amount of impurities such as rosin are obviously
・Fast replaceable filter element;
port: φ6 connector,The arrow points to an outlet at attached to the activated carbon particles in the filter.
・The plexiglass sleeve is convenient for observing the
one end. 3. If it is found that the flow rate of the outlet of the
use of the filter element.
filter obviously decreases, it may be caused by the block-
・Multilayer hierarchical filtration,the filter diameter can
age of the filter, please check whether the filter is blocked
reach 10um;
at this time.
・The sintered activated carbon filter core does not deform
and accumulate. Usage method
・CHANGAI has completely independent intellectual proper- Replacement method
A tetrafluoro tube with diameter of 6 is used to feed the
ty rights.
sampled gas from the inlet of AF1000,and then the 1.Remove the trachea at both ends of the old filter.
filtered gas is fed into the next connection point through 2.Pull the old filter out of the filter bracket.
the connecting pipe of the outlet of AF1000. 3.Install the new filter on the filter bracket;
Technical Specifications 4.Connect the trachea to both ends of the new filter.

Functions: Removal of water,rosin,organic matter,etc.


Material of filter
element: Imported Polymer Polyethylene and
Assembly drawing
Activated Carbon 2 Installation Opening Dimension Diagram
Filtration
diameter: 10um
Working Activated carbon
pressure: -1~+1kpa
Air outlet Air intake
Temperature
range: 5~45°C
Air intake: 1/4"NPT,adapter can be configured
according to need,lower end is intake port
Air outlet: 1/4"NPT,can be configured as needed,the
upper end is the outlet.

Applications Mounting
It is suitable for sample gas filtration in gas analysis indus- bracket
try to remove moisture,ethanol,rosin,dust and so on.

115 116
Filter Filter

AF-2000 AF-4000
Filter Filter

Different fillers (moisture-proof beads:dewatering,


activated carbon:dewatering,rosin,organic matter,etc.).

Technical Specifications Attention Usage method Technical Specifications


Functions: Filtration of Light Dust in Gas 1.When water droplets are found in AF2000 filter, the Use stainless steel pipe or tetrafluoride pipe,etc.
gas should be dried. The filter does not have the function Inlet port: 1/4"NPT (or 6 connector) can be configured
Air intake: 1/4"NPT,adapter can be configured according (Please select the material and diameter of trachea
of dewatering. according to need.The reverse end of arrow
to need.The reverse end of arrow pointing to is according to the use requirements and joints).Sample
2. If it is found that the flow rate of the outlet of the pointing to is the intake port.
the intake port. gas is fed into the intake port of AF4000,and then the
filter obviously decreases, it may be caused by the block- Exhaust
Exhaust filtered gas is fed into the next connection point from the
age of the filter, please check whether the filter is blocked port: 1/4"NPT (or 6 connector) can be configured
port: 1/4"NPT,connector can be configured accord- outlet of AF-4000 to connect the trachea.
at this time. according to need.The arrow points to one
ing to need,arrow pointing to one end of the
3. When the white filter element in the filter is discol- end of the outlet.
outlet
ored or has a large amount of dust impurities, the filter
element should be replaced.

Usage method
Matters needing attention
Replacement method
Use stainless steel pipe or tetrafluoride pipe,etc.
(Please select the material and diameter of the pipe accord- Stop breathing in gas,remove the transparent circular 1.When there are water droplets in the filter,the
ing to the use requirements and joints).Put the sampled glass cover of the filter counterclockwise,then pull out the moisture-proof beads or activated carbon are saturated,
gas into the inlet of AF2000,and then connect the air pipe filter core,sweep the filter with clean gas,blow out the and AF4000 must be replaced immediately.
from the outlet of AF2000 to send the filtered gas to the impurities in the filter,insert a new filter core,then gasket 2.AF4000 must be replaced immediately when a
next connection point. the sealing ring and install the plexiglass cover on the large amount of impurities such as rosin are obviously
small filter,rotate and tighten clockwise.Plug the outlet of attached to the activated carbon particles in the filter.
the filter,then pass the 0.3-0.5MPa gas from the inlet of 3.If it is found that the flow rate of the outlet of the
the filter,then apply the soap foam liquid around the filter filter obviously decreases,it may be caused by the block-
to check whether it is leaking. age of the filter,please check whether the filter is blocked
Glass cover Air outlet
Air intake at this time.
Activated carbon
Mounting bracket
Assembly drawing

Air outlet Air intake base

117 118