SPECIFICATION:

· THISINSTALLATIONSHALLCONFORMWITHTHEPROVISIONOFTHELATESTEDITIONOFTHE SERVICE ENTRANCE


PHILIPPINEELECTRICALCODE,THEREGULATIONSOFTHELOCALAUTHORITIESANDTHE 220V, 1Ø, 60Hz
REQUIREMENTSOFELECTRICALPOWERCOMPANY. 2-150mm² THHN CU. WIRE
1-80mm² THHN CU. WIRE
IN 5" DIA. RSC PIPE
· POWERSUPPLYSHALLBESINGLEPHASE,230V.,2POLE,2WIRE,60HZAC.THERESHALLBEONLYONE
300A MCCB
SERVICEDROPTOTHEBUILDING. SERVICE EQUIPMENT
M KILOWATT HOUR METER

· WIRINGSHALLBEuPVC,UNLESSNOTEDOTHERWISE,MINIMUMSIZESHALLBE20mmTRADEDIAMETER.
WIRESSHALLBECOPPERTYPETHHN,MINIMUMSIZESHALLBE2.0mm².

· ALLMETALNON-CURRENTCARRYINGPARTSOFTHESYSTEMSHALLBEPROPERLYGROUNDED.A
THIRDGROUNDINGWIREOF2.0mm²SHALLBEPROVIDEDFORALLCIRCUITRUNS.

· WIRINGDEVICESSHALLBEFLUSHTYPEANDMOUNTEDASFOLLOWS.
BUSBAR,RATED 300A,2P,60HZ
a.SWITCHES -1.20M.FROMFFL.
b.CONVENIENCEOUTLET
-0.50M.FROMFFL.
-0.20M.FROM COUNTERTOP
-1.20M.FROMFFLOFTOILET
C.OTHERSTOBEDETERMINEDATTHESITE E

· ALLMATERIALSTOBEUSEDSHALLBETHETYPESAPPROVEDFORTHELOCATIONANDPURPOSE.

SM SM SM SM SM SM SM
· THEWORKSHALLBEUNDERTHESUPERVISIONOFAREGISTEREDELECTRICALENGINEERORMASTER
ELECTRICIAN. SM SM SM SM SM SM

ELECTRICAL SYMBOLS:

L I G H T I N G O U T L E T 60 AT 60 AT 60 AT 60 AT 50 AT 50 AT 50 AT 50 AT 50 AT 50 AT 50 AT 60 AT 50 AT

P I N L I G H T

C O N V E N I E N C E O U T L E T E

ACU
AIR CONDITIONING UNIT OUTLET PB-2 PB-4 PB-6 PB-8 PB-10 PB-12
REF
R E F R I G E R A T O R O U T L E T

P A N E L B O A R D PB-1 PB-3 PB-5 PB-7 PB-9 PB-11 PB-13


C1 C I R C U I T H O M E R U N
PB1

Sa 1 G A N G S W I T C H
E1 SINGLE LINE DIAGRAM
SCALE: NTS
Sab 2 G A N G S W I T C H 05
S3W 3 W A Y S W I T C H

SEAL: DESIGNED BY: OWNER: PROJECT TITLE: SHEET CONTENT: SHEET NO:

PROFESSIONAL ELECTRICAL ENGINEER


DRAWN BY:
SPS. NOEL & MERCY BACANTO PROPOSED 2-STOREY COMMERCIAL
CHECKED BY: This drawing acting as an instrument of service is the property of A R. C A R M E L O U. RESIDENTIAL BUILDING E
PTR NO.: TIN NO.: B A N D I L L O N registered architect such as, must not be reproduced of copied in part or in AS SHOWN
SCALE: whole wit hout their per mission. All dr awings must be r etur ned when no longer use. ADRESS: LOCATION: 05
ISSUED AT.: PRC NO.: DATE: -REPUBLIC ACT 9266 ARTICLE IV, SECTION 33 & R.A. 8293 BRGY. AGKILO, PANIT-AN, CAPIZ LOT 3-J-7-D,BRGY. BAYBAY,ROXAS CITY,CAPIZ