D I S T R I B U T I O N S O LU T I O N S

Lifecycle services for low and


medium voltage equipments
ABB - partner of choice in
world-class service

Table of contents

03 Installation and commissioning


04 Training
05 Spare parts and repair service
06 Maintenance
07 Extensions

Upgrades
08 Remote racking of circuit breaker /
contactor for operator safety
09 UFES solutions - switchgear upgrades
for rapid arc fault extinguishing
10 – 11 Fault current limiter Is-limiterTM

Circuit breaker retrofit


12 Roll-in replacement
13 Universal module
14 – 15 Relay retrofit
16 – 17 Replacement
18 – 19 Switchgear temperature monitoring
3


Installation and commissioning
On-site installation and commissioning
by certified ABB experts
Ensure lower risk, faster start-up and optimum performance for
your electrification system, from first operation through the entire
lifecycle of the equipment.
ABB certified service engineers provide expert Installation services
on-site installation, cold and hot commissioning Full installation services include:
for distribution automation products, switching, • Site supervision
limiting, measuring and sensing devices, • Foundation alignment check
switchgear, modular substation packages and • Installation and erection of new equipment
eHouses. • Main bus bars and cubicles connection
• Incoming / outgoing cable connections
ABB service engineers go through rigorous • Insulation level testing
product specific training before they are allowed • Internal wiring check
to carry out service work at a customer site. • Switchgear earthing check
Count on certified on-site installation and • Functional testing and site handover
commissioning by ABB experts for high reliability
and optimum life-cycle performance from Commissioning services
first operation. Full commissioning services include:
• On-site testing of the erected switchboard
The correct installation and commissioning will • Conductivity test on the primary circuits
ensure a high degree of operational reliability. • Insulation test on primary and auxiliary circuits
To achieve a problem-free start up, it is required • High-voltage test on primary circuits
that installation and commissioning procedures • Primary tests on instrument transformers
are followed. The use of service personnel from • Polarity tests on instrument transformers
ABB ensures that the equipment is installed and
put into operation in a safe and correct way. Benefits
• Reliable equipment from the
first day of operation
• Lower risk for unexpected outages
• Faster start-up
• Optimum lifecycle performance
4 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Training
Reach new levels of knowledge
with dedicated training programs
Trained personnel with high expertise allows safe, correct and reliable operation
and reduces downtime. Our training programs for your supervisors, engineers,
technicians, operators and maintenance personnel provide comprehensive and
up-to-date technical expertise for existing and new products, processes and
technology. Learn on your own site, in the classroom or online.

Throughout the value chain, from pre-purchase to Benefits


replacement and product recycling, ABB service With ABB products and systems training,
offers general and product-related technical your benefits are:
training. Courses typically cover safety • Enhanced personnel and plant safety
procedures, correct product operation, routine • Improved productivity
maintenance and basic fault finding. We offer • Reduced downtime
customized curricula to address the unique • More motivated and qualified employees
training requirements of your facility.
Training centre facilities
Classroom training • Demo room with operating models
Formal training courses are provided by product • Product benches for hands-on training
or service specialists and conducted in ABB • Sophisticated learning aids such as
training centers. A training session typically simulations, product cut-outs and
comprises both theoretical presentations and multimedia presentation
hands-on exercises, focusing on the detailed • Well-equipped classrooms
understanding of the design criteria, the
technology and the project specifics.

On-site training
Versatile on-site training services are also offered
by ABB. It is usually more focused on hands-on
training, concentrating on operating the
equipment.
5


Spare parts and repair service
Guaranteed functionality of installations
with original ABB components
Guaranteed functionality of your installations by using original
ABB components, spare parts and kits available for current and legacy products,
including acquired brands. ABB’s channel partner network is strategically
positioned to provide spare parts and repair service throughout India.
Use of standardized processes, tools and metrics ensures that components are
delivered quickly and efficiently to your site.

Spare parts Benefits


Spare parts availability is crucial for on-going • Optimum lifecycle performance of equipment
operations. We maintain a complete stock of • Reliable and safe operation with original parts
strategic spare parts, guaranteeing availability. • Reduced downtime with fast and guaranteed
For emergency requirement of spare parts, our delivery
service team personnel and partners are ready to
provide immediate response to your emergency ABB offers repair services for low and medium
needs. voltage switchgear, vacuum / SF6 circuit breaker
& poles and protection relays. These repair
Legacy support services are designed to deliver trouble-free
Our legacy support provides replacement parts operations and extended product lifetime.
and repairs for previous generations of Our service organization has an extensive
ABB products including AIS, GIS, RMU, indoor / experience in switchgear and the applications
outdoor circuit breakers and auto reclosers. where they operate. This experience enables us to
Spare parts and repair services for ABB legacy deliver improved availability and lifecycle
products are available as long as they are performance of equipment to our customers.
technically and commercially feasible.
6 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Maintenance
Maintain efficiency, availability and safety
with the right maintenance program
By inspecting and analyzing your equipment, we are able to program
maintenance in a targeted and economically advantageous way.
Interventions can be brought forward or delayed according to your priorities. ​

ABB has supplied various low and medium Why ABB?


voltage equipment from its manufacturing • High level of professionalism guaranteed by a
locations. On completion of commissioning, the continuous training process and refresher
equipment is at the peak of its performance. To courses
maintain this condition, it is essential to adopt a • Reduction of plant downtime, thanks to rapid
service and maintenance program for this asset. diagnosis using specific testing instruments
An appropriate maintenance program reduces and fault identification
the risk of failures and / or unexpected • Numerous solutions for increasing safety of
shutdowns and extends the lifetime of the operators, devices and process, preventing the
equipment, thus lowering the overall operational principal risks
costs. • Reduction in maintenance costs (direct costs
The maintenance strategy is the key for reduced of emergencies, indirect costs of production
maintenance cost and optimized plant operation. losses)
ABB service team fully supports maintenance:
from inspection, mechanical and operational
checks and troubleshooting to continuous
monitoring for proactive maintenance planning.
Our certified experts are there to support your
maintenance strategy, according to initial
specifications and expected asset lifetime.
7


Extensions
Extension of any kind of switchgear

Extension of any kind of switchgear with either original legacy equipment or


panels of the active product lines. All discontinued switchgear of the active and
legacy ABB brands, and also non-ABB equipment can be extended by adding
new panels.

— Key features We support following range of legacy


01 VHE12S
— • Same original panels or new active products switchgear panels:
02 VHA12S • Directly or using an adaptation, integrated into • VHE12S - 12kV, 40kA for 3 sec,

03 UniSafe the bus bar compartment, with a dedicated VCB switchgear
— transition panel • UniSafe - 12kV, 26.3kA for 3 sec,
04 VHA36
VCB switchgear
Key benefits • VHA12S - 12kV, 40kA for 3 sec,
• Increased capacity of the network SF6 CB switchgear
• Overall switchgear life time extension • VHA36 - 36kV, 31.5kA for 3 sec,
SF6 CB switchgear

— — — —
01 02 03 04
8 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Upgrades
Remote racking of circuit breaker /
contactor for operator safety
A safer operating environment for electrical substation personnel through the
proven method of adding distance between the operator and arc flash incident
energy at the switchgear site.

The process of racking a circuit breaker / ABB can offer integrated remote racking
contactor into and out of the connected position solutions implementing the remote control of
is one of the most frequent exercises that expose racking in and out operations of the circuit
an operator to risk. A malfunction during this breakers / contactors.
operation has the potential for catastrophic
consequences to personnel and equipment. Benefits
Increased focus on operator safety has caused • Increased personnel safety, thanks to the
owners to question the adequacy of prior distance between the circuit breaker /
switchgear designs that require a manual racking contactor and the operator
of circuit breaker / contactor. • Enhanced switchgear operability prevents
human errors due to manual operations
Maintaining a safe distance between personnel • Racking operations are performed by applying
and equipment during critical operations such as the recommended force, thereby preventing
rack-in / rack-out of circuit breaker / contactor damage to the mechanism and interlocks
provides the most effective means of avoiding • Racking operation possible through SCADA
injury by keeping people out of harm’s way.
9


Upgrades
UFES solutions - switchgear upgrades
for rapid arc fault extinguishing
Innovative arc flash mitigation in less than 4 ms, the highest possible level of arc
flash protection for personnel and equipment, maintenance of secure power
supply and the reduction of production stoppages.

— In the event of an internal arc fault, the • 3 primary switching elements for ultra-fast
01 Ultra Fast
Earthing Switch temperature might go up to 20000 degrees initiation of 3-phase short circuit earthing
— Celsius during which the metal burns & vaporizes, after detection of a fault by the electronic and
02 Draw-out unit
hot gases are released and heavy damages occur thereby eliminating the arc by resulting the
to the equipment and personnel in vicinity. breakdown of internal arc voltages
In such cases, the losses are very huge.
It has an extremely short tripping time of <4 ms
The latest technology - (after detection)
Ultra Fast Earthing Switch(UFES ) provides:
• Active internal arc protection in addition to Benefits
available passive protection, applicable for Speed - Nearly immediate extinction of an
short-circuit proof, air-insulated switchgear internal arc by fastest intervention of the
• Highest possible protection for switchgear in Ultra Fast Earthing Switch.
regard to the hazardous impacts caused by
an internal arc Safety - Greatly enhanced protection for
personnel, switchgear and the environment.
The Ultra Fast Earthing Switch (UFES ) Drastically reduced internal arc duration ensures
device has : minimized pressure and temperature rise.
• Electronic tripping unit for fast & reliable This leads, as a consequence, to minimal impacts
interface to external arc detection systems at the fault location.
and tripping of UFES primary switching
elements Savings - Greatly increases system and process
availability in combination with drastically
reduced repair costs.

— —
01 02
10 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Upgrades
Fault current limiter Is-limiterTM
Customized fault current limiter solution that meets the highest requirements
for critical and complex applications resolving all possible short-circuit
challenges. ABBʼs fault current limiters disconnect the fault affected part of the
system extremely fast so that the short-circuit withstand capability of the
system is not violated.

— Why are short-circuit fault levels increasing? Why must short-circuit currents be limited?
01 Is-limiter TM
panel and insert A growing energy demand and the need for stable Each equipment in an electrical network has a
power are two of the largest challenges faced by certain permissible short-circuit withstand
consumers, power producers and network capability, which if exceeded will have hazardous
operators. consequences for equipment, personnel and
environment. If electrical equipment like
With this rising worldwide energy demand, switch- boards, switches, transformers or cables
existing power distribution systems and power are subjected to short-circuit currents higher
grids are being expanded and increasingly than their withstand capability they can be
meshed. This causes short-circuit fault levels to destroyed by the dynamic and thermal stresses.
increase, resulting in yet another challenge.


01
11

Does my equipment withstand a Typical applications


short-circuit fault? The IS-limiter™ can be used in various
Electrical equipment is usually tested according applications providing very high and
to the relevant standards to withstand the fast fault current breaking capability at
permissible short-circuit currents. Those are the high operating currents.
rated peak withstand current, the short-time The most common applications are:
withstand current and the rated short-circuit • Connecting two independent systems without
duration. If one of these parameters is exceeded, exceeding equipment short-circuit rating
the equipment will most probably face • Bypassing a reactor
severe damage. • Connecting an additional power source
(e.g. generator or grid connection)
What do ABB’s fault current limiters do? • Interfacing public networks and consumer
The IS -limiter™ limits the short-circuit current owned power supply systems
before the first current peak is reached such that
the equipment rating is not exceeded. They
isolate the fault affected part of the network
ABB will support you to identify
within milliseconds (ms) and ensure that the the place of installation which
short-circuit level is not exceeding the systems’
withstand capability. They facilitate flexible
provides most effective fault
power distribution, power system expansion, current limitation while
independent power production, reactor
replacement and many more such applications
maintaining operational reliability.
without considering the equipment short-circuit
withstand capability as a constraint.

Optimizing your investments


• Eco- and cost-efficient fault current limiters
• Optimized load flow behavior
• Reduction of energy losses in the system

Maximizing your output


• Increase uptime and redundancy of the power
distribution systems
• Flexible connection to new and existing
switchboards
• Installation in greenfield and brownfield
projects

Protecting your assets


• Type tested equipment
• Redundant control unit for additional safety
• World’s fastest fault current limiters to protect
systems and processes
• Fault current limitation in harsh environments
• More than 3,000 installations in more than
85 countries
12 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Circuit breaker retrofit
Roll-in replacement
Circuit breaker retrofitting is a cost-effective alternative to complete switchgear
replacement. ABB Service experts conduct site audits on existing installations
to assess the condition of the equipment, recommend the most suitable
solution and technically support the most appropriate investment.

Typically, retrofitting constitutes replacement of Roll-in replacement:


vital equipment having similar or advanced In roll-in replacement solution, the new circuit
features, for life extension, reduced maintenance breaker is re-engineered in such a way that it fits
and improved functionality. This includes into existing switchgear with no / minimum
upgradation and modernization of basic modifications in the panel.
equipment and allied parts. The retrofitted • Replica of existing circuit breaker
switchgear offers far greater system reliability, • All parts are made with latest tools and
long-term availability of spares and increased designs to provide maximum reliability
safety to the operators with minimal investment • Retrofit circuit breaker is interchangeable with
and downtime. existing circuit breakers

ABB is a full system provider of roll-in retrofit Benefits


solutions for ABB & non-ABB switchgears, • Significant lifetime extension
from the proposal and design, through the • Lower maintenance requirements
manufacturing and testing, up to the installation • Long time availability of spare parts
and commissioning. • Latest generation apparatus
• No / minimum modifications in
existing switchgear
• Short implementation time for replacement
• Minimum shutdown of the switchboard
• Smooth site activity
• Warranty on the conversion work
13


Circuit breaker retrofit
Universal module
Retrofill is one of the retrofit technical solution used by ABB. Universal module is
the latest ABB retrofill design concept in order to easily connect the new breaker
to a wide range of existing non-ABB panels.

— Concept Ease of use and robust


01
36kV Universal module Universal module comprises a cassette that hosts • CB mechanical push buttons accessible
— a standard circuit-breaker connected to the from front door
02
12kV Universal module existing switchgear by an adaption system. • Single shot handle for the door
• Robust structure with Aluzinc sheets
The adaptation system allows a completely • Inspection window of toughened glass
standard ABB withdrawable apparatus to be • Mechanically stiffened door with padlocking
fitted to the original switchgear. The result is a facility
great improvement in reliability, safety,
maintenance and performance. Safety upgraded
• The original shutter system and all the
Benefits relevant interlocking are replaced with new
Maintenance and repair aspect standard ones installed from the factory on
• The new apparatus mounts all standard spare the universal module
parts with all the benefits in terms of delivery • Shutter and circuit breaker movement are
time and price interlocked to enable all necessary safety
• Equipment and spare parts are features
interchangeable with new ABB extension • Option for remote racking of apparatus
panels (UniGear) and additional switchgear • Optionally integrated with temperature
• Same operational interface and maintenance monitoring sensors near apparatus spouts
approach for the equipment installed in
universal module and new ABB panels Technology
• Universal module solutions are fully type
Modernization process tested according to IEC standards
• The use of standard breakers makes them
ready without any modification for future
ABB replacement switchgear, providing
an optimized investment for the
next substation renewal

— —
01 02
14 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Relay retrofit
Replacement of any old protection relay
with innovative, modern relay
Targeting reliable and smooth relay retrofits, ABB offers different
relay retrofit solutions for replacement of protection and control relays.

ABB’s relay retrofit solutions offer smooth and Benefits


controlled replacement of existing protection • Extended switchgear lifetime with new
relays with the latest protection and control protection relay and technology
technology. The result is extended switchgear • Assured, future availability of lifecycle services
lifetime, full availability of relay life cycle services, • Enhanced personnel safety with access to the
and the possibility to adapt the power protection latest protection and control functionality
system to meet new requirements. • Offers substantial savings in time and
resources with a very fast and structured
The offering is typically based on the use of replacement process
protection and control relays from the Relion® • Optional built-in arc fault protection enhances
product family as replacement devices. personnel safety

ABB offers following to meet your needs:


• Replacement of complete metering box or
metering door with latest design
• New comprehensive numerical relays
with latest technology
• New switches, meters & indication
lamps along with new wiring
15


01 Module A Module B Module C
Before retrofitting
— Relay retrofit with Relay retrofit with Relay retrofit with
02 Description
replicated metering box replicated door cover plates
After retrofitting
Latest ABB make protection
1 relays suitable for SCADA Yes Yes Yes
application

Replacement of auxiliary Yes for auxiliary


2 relays, meters, Indication Yes relays & devices No
lamps, TTB etc mounted on door

Replacement of terminal
block, AC / DC switches,
3 Yes No No
fuses, PVC channels, toggle
switches, MCBs etc.

4 Aesthetic Best Best Good

5 Installation time (approx) 6 hours 6-8 hours 8-10 hours

— —
01 02
16 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Replacement
Lifecycle management
Replace your low / medium voltage equipment and keep your business running.
We help to replace obsolete equipment entirely, partially or step-by-step with
minimized impact on your primary processes.

— Whenever there is a need to replace an entire Replacement activities includes:


01 Old indoor
switchgear low / medium voltage product or system - from • Dismantling of existing equipment
— ABB or any other manufacturer - we can offer the • Removal of power and control cables
02 New indoor
switchgear widest portfolio for every need. Our experts will • Supply of new equipment
help select an optimal replacement product with • Dismantling of exiting base frames and
correct features for the application: protection & modification of civil foundation work
control relays, replacement breakers, switching, • Modification of power and control cables
limiting, measuring and sensing devices, trench
switchgear or modular substation packages. • Installation and commissioning of
new equipment
ABB offers replacement of low / medium voltage • Laying & termination of power and control
equipments in indoor & outdoor substations. cables
Complete turn key packages offered by us • We also offer decommissioning, disposal and
includes design, engineering, supply, unloading, recycling of material and SF6 gas management
shifting, dismantling, storage, installation and
commissioning of equipments.

— —
01 02
17


03
Old outdoor substation

04
New outdoor substation


03


04
18 DISTRIBUTION SOLUTIONS SERVICE TECHNIC AL BROCHURE


Switchgear temperature monitoring
Early hotspot detection effectively
reducing risk of internal arc fault
— The hotspot detection in medium voltage
01 ABB temperature
deterioration due to excessive heating.
monitoring solution switchgears is one of the most crucial condition The lifetime of the insulation decreases rapidly
with SAW sensors monitoring functionalities. ABB temperature

resulting in weak areas sensitive to dielectric
02 Overheated monitoring solution gives very high-level stressing during subsequent operation. As a rule
cable termination performances if compared with other equipment
after flashover
of-thumb, we can say the insulation lifetime is
— available in the market (e.g. IR windows with reduced by half for each rise of 10°c in insulation
03 Arc-fault effect IR cameras). It allows for early fault detection,
on substation
average temperatures. An aged insulator
preventing insulation deterioration and lowering increases dramatically the switchgear probability
risks of insulation faults. of failure in form of an internal arc fault, which
can result in long-term power supply outage and
Overheating effects: huge consequential damages.
The temperature of the primary circuits has a
dominant influence on the switchgear insulation Since periodical visual inspections might not
life. If a loose joint within the switchgear creates accurately estimate the remaining life of
a hotspot on the primary circuit, the insulation insulators, the detection of primary circuit
close to the hotspot can suffer serious hotspots becomes one of the crucial health
condition monitoring tasks, and a key input to
implement condition-based maintenance.


01

— —
02 03
— Failure causes: Safety
04 Areas of interest
for hotspot detection A hotspot in the switchgear can develop as result • Reducing catastrophic failures which impact
of different operational situations, such as: human & asset life
• Loose joints due to vibrations, • Improved operator protection - no more
unusual operating shocks thermography needed in close proximity
• Power cable loose connections as result of of live switchgear
severe short-circuits and aged clamping
arrangement Technology
• Mechanical damage of sliding power contacts • Sensor's performance proven in
during equipment handling outside the panels HT environment - Type tested in AIS for LIV
• Ablation of contact surface of sliding power (Up to 170kVp) & STC (Up to 40kA)
contacts due to excess of racking operations • SAW technology sensors with piezoelectric
above the prescribed limits substrate quartz - No power circuit charging
• Contacts resistance increase caused by needed for sensors operation
oxidation or corrosion due to unfavorable • Suitable for both green and brown field
environmental conditions (humidity, marine applications up to 36kV
ambient, air chemical pollution, etc.)
• Long maintenance intervals due to equipment Project
utilization in continuous process plants. • Short implementation time
• Minimum shutdown of the switchboard
The points of interest are therefore temperatures • Smooth site activity
on or close to the bolted joints and sliding
contacts on primary circuits (see fig. 4). Investment
• Optimized maintenance schedule
Benefits: • Reduce operational costs
Reliability
• Maximize uptime - continuous temperature Key technical features:
monitoring providing alarms before • Wireless & battery less SAW sensors
system fails • Measuring temperature range of
• Avoid unplanned outages which directly affect - 25°C to 150°C
revenue generation • Connectivity of electronics (transceivers)
on Modbus-RTU protocol (Over RS 485 through
RJ45) for measurement on touch HMI or
SCADA

Busbar
joints

Circuit
breaker
spouts

Cable
terminations


04
Doc. ID: 1VYN401890-102 © 2020 ABB. All rights reserved.

— —
For more information please contact: We reserve the right to make technical We reserve all rights in this document and
changes or modify the contents of this in the subject matter and illustrations
ABB India Ltd document without prior notice. With contained therein. Any reproduction,
Plot No 79, Street No.17, regard to purchase orders, the agreed disclosure to third parties or utilization of
MIDC Estate, Satpur, particulars shall prevail. ABB does not its contents – in whole or in parts –
Nashik – 422 007 accept any responsibility whatsoever for is forbidden without prior written
Maharashtra, India potential errors or possible lack of consent of ABB.
Phone: +91-253- 2201200 information in this document. Copyright© 2020 ABB. All rights reserved.
Email: ppmvsupport@in.abb.com