Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ENTP-EN-TPL-05911-E_3

PLAN VIEW PLAN VIEW PLAN VIEW KEY PLAN


A CONNECTING AREA FOR LINKS LOCATION
A
Scale: 1:50
Scale: 1:50 Scale: 1:50
PN 10 500.000
650
R48300 R31300 R48300
R46000 R46000 TANK 0T-3101
CJ 0°

R38800
R31300 0.216° B4 B1
270° 90°

0.150°

0.216°

0.150°

PE 11 000.000
B 270° 90° 180°
B

B3 B2

180°

40X0.183°=7.320°

41 x 0.183°=7.503°
41 x 0.183°=7.503°
NOTE

42 x 7.503°
42 x 7.503°

7.503°
A 1- CHARACTERISTIC CONCRETE CYLINDER STRENGTH (at 28 days):
-
- SLAB, WALL and ROOF : 40 MPa.
C C
2- SPECIFIED YIELD STRENGTH OF REINFORCEMENT STEEL:
-fy = 500 MPa (Cryogenic and not cryogenic rebars).

3- NOMINAL CONCRETE COVER:


-Internal faces (Slab, wall and roof) : 40mm.
-External faces (Slab, wall and roof) : 60mm.

4- -ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE STATED.

0.183°
0.150° -ALL LEVELS ARE IN METERS RELATIVE TO LNG TANK LEVEL REF.

0.150°
0.216° -ALL ANGLES ARE IN DECIMAL DEGREES.

0.216°
-ALL COORDINATES ARE IN METERS.
D D

0.183°
5- REFERENCE LNG TANK LEVEL : +0.000m (TOP RAFT SURFACE ELEVATION)

0.183°
= +100.400m (PE : PLANT ELEVATION)
2 5 =+6.400 (GD)

Starter bars 508 were cut, and "L" bars Diameter designation
Bar Type For cryogenic bars only
(Bar mark B in BBS) were added
D - Deformed bars (Grade 500W) K for Krybar
with threaded couplers. 5 2 P - Plain round (Grade 500R) T for Tempcore
Number of bars Spacing
Starter bars 503 and 506 were cut, and "L" bars
Sketch
E SECTION B-B (Bar mark A in BBS) were added
with threaded couplers.
E
SECTION B-B WALL BETWEEN SLAB AND OPENING Bar mark
Scale: 1:25 Scale: 1:25
(Staggered bar,
Slab and Roof Wall threaded bar, coupler...)
2 4 B1 : Bottom 1st layer IF1 : Inner face 1st layer
B2 : Bottom 2nd layer IF2 : Inner face 2nd layer
T1 : Top 1st layer OF1 : Outer face 1st layer
T2 : Top 2nd layer OF2 : Outer face 2nd layer
150
805

2060 mini
F F
±0.000
1510 mini
1300

G G
REFERENCE DRAWINGS CIVIL:
- L001-03100-CX-4180-28965C-1200 : Slab formwork-Concreting Stages-0T-3101
Concrete compressive strength (cylinder test) f'c=40 MPa - L001-03100-CX-4180-28965C-1201 : Slab formwork-Plan view & sections-0T-3101
Anchorage length Class B splice - L001-03100-CX-4180-28965C-1213 : Vertical tendons-Layout-0T-3101
(mm) Lap length (mm) - L001-03100-CX-4180-28965C-1214 : Vertical tendons-Elevations - Details-0T-3101
Bar
size Slab & roof Wall bar/ Slab & roof Wall bar/ - L001-03100-CX-2397-28965C-1200 : Slab Part 1 - Lower circumf. layers-0T-3101
top bar Slab & roof top bar Slab & roof - L001-03100-CX-2397-28965C-1202 : Slab Part 1 - Upper circumf. layers-0T-3101
bottom bar bottom bar
10 M 340 300 450 390
- L001-03100-CX-2397-28965C-1204 : Slab Part 2 - Lower circumf. layers-0T-3101
15 M 480 370 630 490 - L001-03100-CX-2397-28965C-1206 : Slab Part 2 - Upper circumf. layers-0T-3101
20 M 590 450 770 590 - L001-03100-CX-2397-28965C-1208 : Slab Part 3 - Lower circumf. layers-0T-3101
25 M 1130 870 1470 1140 Vertical prestressing - L001-03100-CX-2397-28965C-1210 : Slab Part 3 - Upper circumf. layers-0T-3101
H 30 M 1510 1160 1970 1510 tendon axis - L001-03100-CX-2397-28965C-1212 : Slab Part 4 - Lower circumf. layers-0T-3101 H
35 M 2050 1580 2670 2060 - L001-03100-CX-2397-28965C-1214 : Slab Part 4 - Upper circumf. layers-0T-3101
40 M 2870 2210 3740 2880 - L001-03100-CX-2397-28965C-1221 : BBS-Slab - Openings-0T-3101
45 M 4340 3340 5650 4350 R=46000
Orthogonal Radial
reinforcement reinforcement AUTHOR DRAWING No.: L9GC-EVJ-DRW-27111
2 SECTION A-A 2 2
Scale : 1:25
R=31300 6 R=38800 2 As Built G.Ledain M.Florea A.Alerany 14/Mar/2024
Additional 25/30M
1 Approved for Construction S.Sennoaj S. Velin A.Alerany 12/Aug/2020
J (400 W grade) 0 Approved for Construction G.Ledain S. Velin A.Alerany 31/Mar/2020 J
non-structural vertical
200 A Issued for Review G.Ledain S. Velin A.Alerany 13/Jan/2020
400 400 rebar stiffener @
600mm spacing was REV. NO. DESCRIPTION BY CHKD APVD DATE
400 200 400 130 260
left in place REVISIONS
2 7 260

25M Spacer bars 2000


40

40
+0.000 2670 200 180 60

60
between T2 and T3 40

60
K 1470
249 236 185 Opportunity for British Columbia. Energy for the world
LNG CANADA PROJECT K
1510

290
172
100 160 120 172 249
0 1 This document is confidential. Neither the whole nor any part of this document may be used,
reproduced, copied, stored in any retrieval system or transmitted in any form or by any means
1510 3
1720 (electronic, mechanical, reprographic, recording or otherwise) or disclosed to any third party
2260 160 without the prior written consent of LNG CANADA DEVELOPMENT INC. All rights reserved.
60

-0.800 170 4
2320 TITLE:
170
160 Slab
2060 Temporary Openings
60

L -1.300 L
1 RFI-K025-041 0T-3101 - LNG Storage Tank

2 RFI-K025-057 320 320 400 400 200 180 360 360 2x6 Spacer Ø20 UNIT: U3100
5 L9GC-EVJ-FCN-07119/ @1.281° LOCATION: PLANT:
160 200 180 KITIMAT, BRITISH COLUMBIA, CANADA LNG CANADA
3 RFI-K025-062 RFI-K025-000103 B Spacer Ø25 mini
- DWG No.: SIZE: REV.:

M 4 RFI-K025-075/RFI-K025-082 6 RFI-K025-077 M
L001-03100-CX-2397-28965C-1221 A1 2
L9GC-EVJ-FCN-07113/
FILE NAME:
RFI-K025-000097 7 RFI-K025-038
L001-03100-CX-2397-28965C-1221_R2