Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ENTP-EN-TPL-05911-E_3
l

RFI-K025-130 / VIEW E-E


F-F SECTION A-A SECTION B-B
B2
A D1 L9GC-EVJ-FCN-07131 /
RFI-K025-000119
Scale: 1:25 Scale : 1:25

1
1
1 1
Scale : 1:25
1

1
111
1 1 -~ -
KEY PLAN
A
1 1
1 1 PN 10 500.000

1( 6 □
1 1 1 1
2x10-D-25M
052 1 1 056 1 111 1 111
TANK 0T-3101
153)~ 1 1 1 1 1 1 1 0°

1240
1 1
1 /~
1
2x4-D-20K 1 B4 B1
l
155 2x10-D-20M 1 1
270° 90°

700
690

690
1

590
1 1
12-D-20M 2x2-D-15M

PE 11 000.000
B 055 111
270° 90° 180°
B
+28.400 1 +28.400 1 1 1
+28.400
'
B3 B2

180
1 1 1 ~ia-
'::~-
06],
. 1 ',<~ _J

d:
1 . 1
~

180
1 180°
61-A .L..Z. ....-- ,,_ ....-- ,'-....' .L...... 1 1
1
2x5-D-20M

180
1 • 1 •
11 057 111
NOTE
1 1
.

310 170
1 1 1
.L ' .1. 1 1 1 1

-- ...F"-- --
J 1- CHARACTERISTIC CYLINDER STRENGTH (at 28 days):

- -= - -= - - ..... -
r ~-r- ,-- ~ 60-B 1 (])11
' -4-
'71""
7 "- L .... - SLAB, WALL and ROOF : 40 MPa = 40 N/mm2.
~
~ -- ;..z.,L~

60-A r-- _,_r-_,.__,.. ..L......../- 1

.
/1

C - C
, 2- SPECIFIED YIELD STRENGTH OF REINFORCEMENT STEEL:
D2

180 150
057 ~
15 2,----- i:.
-fy = 500 MPa (Cryogenic and not cryogenic rebars).
' r

150
-
1 1
4x2 D 10M 061 ] 1 1
3- NOMINAL CONCRETE COVER:
061, 1 1 -Internal faces (Slab, wall and roof) : 40mm.
q:

180
59-A ..... ,,_.,,,L I'-
~
.....
-/ ,,_ ,_ ,,_
....::.... ........
~
....L. ........ _z- r-..L.......::....
/- ..... ...::...
,,_ ,,_ ,<- ..L.._.L._ ........ :LIL....L ........ --<-
-External faces (Slab, wall and roof) : 60mm.
~ . . . . : : . . . . ........ ...::.. ..... L I.Lt'--'- tt'-...::..t-"-....L

130 180 140 310150 180


1 1 4- -ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE STATED.
1 111 -ALL LEVELS ARE IN METERS.

D 58-A
~:..z:___,_...::..,....
'
~\--------îtr-:...:;i~~-
..... . .::.. .......... .L..L_
T .1. -

4
- ~
.L
~
e--- -
_E_
--
-
+- - L - - - ~ - . L . . L58-B
~
D1
- 01
1 1
051 -ALL ANGLES ARE IN DECIMAL DEGREES.
-ALL COORDINATES ARE IN METERS.
D
-PLANT ELEVATION IS SPECIFIED AS FOLLOW,
062 EL + 100 000mm = GD +6.0 m

1240
~

140
' HIGHEST POINT OF PAVEMENT (HPP) IS SPECIFIED
2x2 D 10M ON DRAWING.
060 060 ]
. .

690
1 1

700

690
590
q:

180
57-A 5- REFERENCE LNG TANK LEVEL : +0.000m (TOP RAFT SURFACE ELEVATION)

-
= +100.400m (PLANT ELEVATION)
+25.200 +25.200 +25.200
,-..; ~
- -
1 1
Diameter designation

60
r:: - - - 56-B
Bar Type For cryogenic bars only
180 310

/ i, _,_ ,,_ .f-


r - r- ,'- ,,_ ~ --.. ---.w .;;: ... - -- .....-
L . . . / -.... ""- 1
D - Deformed bars (Grade 500W) K for Krybar
56-A .......... ~ .... - ... ,.... ............. ,.L......... -, 1
E ::=::::: . . .--_ -- . . . - --- - . . . J P - Plain round (Grade 500R) T for Tempcore E
007' ., ., r
1
Number of bars Spacing
1 lJ
. 005 1
2x10-D-25M
. Sketch
150 180

1 1 1

--- 010 q ll
325 110 170

1
55-A ,_ ,,... L iL_....::.... ........ ....::... .- ~
11 11 Bar mark
~ - -f005 006 105 2x10-D-20M
... - 1
1
1 1
1 1 Slab and Roof
B1 : Bottom 1st layer
Wall
IF1 : Inner face 1st layer
(Staggered bar,
threaded bar, coupler...)
54-B 1 1
B2 : Bottom 2nd layer IF2 : Inner face 2nd layer
54-A 1 1 1
T1 : Top 1st layer OF1 : Outer face 1st layer
1
C2
110 180 150

T2 : Top 2nd layer OF2 : Outer face 2nd layer


F -r- •
- 1
111 F
4x2-D-10M •
010
""'c
- 010 ]
.
1 1
350 135 180

4 - 1 1 1
53-A / -/----/ -
..:.........t:,,._
,,_
....
,L
.....
r- 7 .z::. - <- -

-r-
L:::::.
r
- -
,,_ f-

- r-
L
,L L_r-

r-.....
<-
.....
r-,...-L
- -

009
1 •

1 .
1
2x2-D-15M 01
1 1
Concrete compressive strength (cylinder test) f'c=40 MPa

Bar
Anchorage length
(mm)
Class B splice
Lap length (mm)
1 1 Slab & roof Wall bar/ Slab & roof Wall bar/
C1 1 size
top bar Slab & roof top bar Slab & roof
~
111

52-A TL
z; T L -- - .:z:... ..
................... 52-B r -
10 M 340
bottom bar
300 450
bottom bar
390
009 J
90

15 M 480 370 630 490


- J 20 M 590 450 770 590
90

' 25 M 1130 870 1470 1140


2x4-D-20K
160

1 1

- =- -- -- :
G 30 M 1510 1160 1970 1510 G

-
1 1 35 M 2050 1580 2670 2060

-
85 180

51-A ;;, 2'._ -/_;;;;_- /


,,:;;,-
1 •
+22.000 QII +22.000 40 M 2870 2210 3740 2880
= ~ :a= àa àa = = = éa ~....::.... L .... ....::...._._.,,__,_
y 45 M 4340 3340 5650 4350
- -
1
- -, -, "' "' - -- - - - /

1 1
+22.000 1
1
1 1 REFERENCE DRAWINGS CIVIL:
- L001-03100-CX-4180-28965C-1205 : Wall - Concreting Stages - 0T-3101
1
1

1/2 SECTION C1-C1 1/2 SECTION C2-C2 - L001-03100-CX-4180-28965C-1206 : Wall - Horizontal Section - 0T-3101

6 □ A - L001-03100-CX-4180-28965C-1207 : Wall - External Elevation - 0T-3101


B
001 011 002
~ 102 003
~ 011 002 1 1 (ON ANCHORAGE 19T15)
Scale 1:25 3-D-20M OF1 - -
(BETWEEN TENDONS)
Scale 1:25
-
-
L001-03100-CX-4180-28965C-1208 : Wall - Sections and Details - 0T-3101
L001-03100-CX-4180-28965C-1211 : Wall - Buttresses elevations - 0T-3101
1 1
- L001-03100-CX-4180-28965C-1212 : Wall - Details on buttresses - 0T-3101
H Starter bars see drawing - L001-03100-CX-2397-28965C-1254 : Wall lifts 6 to 12-Inner face reinforcement-0T-3101 H
L001-03100-CX-2397-28965C-1304 - L001-03100-CX-2397-28965C-1266 : Wall lifts 5 to 12-Outer face reinforcement-0T-3101
DETAIL D1 Outer face reinforcement see drawing - L001-03100-CX-2397-28965C-1304 : Wall-Buttress B2 - Lifts 6 and 7 - Reinf. - 0T-3101
- L001-03100-CX-2397-28965C-1313 : Buttress B2 - Lifts 8 and 9 - BBS - 0T-3101
SECTION D2 Additionnal rebars for anchorages
Scale 1:10
D2 L001-03100-CX-2397-28965C-1266
E AUTHOR DRAWING No.: L9GC-EVJ-DRW-27241
Scale 1:10 - r -
0x4-D-15M See DETAIL D1
D or 19T15 160
[ 9-D-20K
t==+===========r~----;-

490

10x4-D-15M 3x125(
m ean)
098 For 19T15 1 As Built E.Corlay M.Florea 1 A.Alerany 22/Mar/2024
J 590 mini
0 Approved for Construction J.Baron M.Florea A.Alerany 12/Oct/2020 J
¾ A Issued for Review S.Sennoaj M.Florea A.Alerany 12/May/2020
~ 590 mini 590 mini REV. NO. DESCRIPTION BY CHKD APVD DATE
1
10x4x2-P-10M REVISIONS
1
To unbend
1
1 4-D-2

0
1
1 ' OF2
1
1 { i 390 Inner face reinforcement see drawing
~
1
1
1
1 L001-03100-CX-2397-28965C-1254
OF2
1 D1
K LNOCANADA
Opportunity for British Columbia. Energy for the world
LNG CANADA PROJECT K
1/2 SECTION D1-D1
(ON ANCHORAGE 19T15)
Scale 1:25
2-D-20M OF1
6
0
10-D-20K
1/2 SECTION D2-D2
(BETWEEN TENDONS)
Scale 1:25
This document is confidential. Neither the whole nor any part of this document may be used,
4-D-15M reproduced, copied, stored in any retrieval system or transmitted in any form or by any means
;(062 OF1 (electronic, mechanical, reprographic, recording or otherwise) or disclosed to any third party
without the prior written consent of LNG CANADA DEVELOPMENT INC. All rights reserved.

TITLE:
TOLERANCE : See DETAIL D1
WALL - BUTTRESS B2
Vertical bars include an additional length of 100mm which allows a tolerance 8-D-20K
15 2)---'~-- '
for reinforcement mesh of ±50mm [ LIFTS 8 and 9 - REINFORCEMENT
L Concrete compressive strength (cylinder test) f'c=40 MPa L
Anchorage length
(mm)
Class B splice
Lap length (mm) 590 mini
0T-3101 - LNG Storage Tank
Bar (01) SAFETY PROTECTION FOR STARTER BARS
size Slab & roof Wall bar/ Slab & roof Wall bar/
top bar Slab & roof top bar Slab & roof
bottom bar bottom bar
12 K and T N/A 300 N/A 390 590 mini 590 mini UNIT: U3100
LOCATION: PLANT:
16 K and T N/A 370 N/A 490 01
20 K and T N/A 460 N/A 600 KITIMAT, BRITISH COLUMBIA, CANADA LNG CANADA
25 K and T N/A 860 N/A 1120
32 T N/A 1310 N/A 1710
Construction bars DWG No.: SIZE: REV.:
Wall reinforcement installation sequence order : Ø15M @300mean
M 9x3-D-16K L001-03100-CX-2397-28965C-1312 A1 1 M
1 : Wall Inner face prefabricated panels reinforcement
2 : Buttress prefabricated reinforcement 2x3-D-20M
3 : Wall Outer face prefabricated panels reinforcement OF2 1 1 9x6-D-16K FILE NAME:
OF2 L001-03100-CX-2397-28965C-1312_R1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ISO A1
L001-03100-CX-2397-28965C-1312_R1.dwg

You might also like